1
|
Mito T, Ishida H, Seki Y, Shirayama T, Ukai Y, Sasaki H. Comparison of Postoperative Axial Rotation of the Toric Intraocular Lens in Cataract Surgery Combined with Vitrectomy versus Cataract Surgery Alone. Ophthalmologica 2024; 247:224-230. [PMID: 39004075 DOI: 10.1159/000539986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 06/19/2024] [Indexed: 07/16/2024]
Abstract
INTRODUCTION This study compared the postoperative axial rotation of the toric intraocular lens (T-IOL) after cataract surgery combined with vitrectomy versus cataract surgery alone. METHODS This retrospective, non-randomized, observational study enrolled patients who underwent cataract surgery combined with vitrectomy in one eye and cataract surgery alone in the contralateral eye. AcrySof Toric IOLs (Alcon Laboratories) were implanted in both eyes of the same patient. The axial rotation of the T-IOL was analyzed 3 months postoperatively using photographs obtained during and after surgery. In the combined group, T-IOL axial alignment was performed before vitrectomy. Preoperative corneal astigmatism and postoperative residual astigmatism were also compared in both groups. RESULTS This study examined 36 eyes of 18 patients (74.7 ± 6.8 years). The axial rotation was 2.94 ± 1.70° in the cataract group versus 3.06 ± 2.34° in the combined group 3 months postoperatively, and the difference lacked significance (p = 0.98). In the combined group, the mean axial rotation during surgery was 2.17 ± 1.80°. Axial rotation within 5° was observed in 17 of 18 eyes (94.4%) in the cataract group and 16 of 18 eyes (88.9%) in the combined group, with no significant difference (p = 0.54). The comparison of postoperative residual astigmatism with preoperative corneal astigmatism revealed a significant improvement from 1.49 ± 0.40 D to 0.39 ± 0.47 D in the cataract group (p < 0.0001) and from 1.61 ± 0.40 D to 0.42 ± 0.43 D in the combined group (p < 0.0001). CONCLUSIONS The postoperative axial rotation of the T-IOL in eyes that underwent cataract surgery combined with vitrectomy was stable and comparable to that of eyes that underwent cataract surgery alone.
Collapse
Affiliation(s)
- Tsuyoshi Mito
- Department of Ophthalmology, Kanazawa Medical University, Uchinada, Japan
| | - Hidetoshi Ishida
- Department of Ophthalmology, Kanazawa Medical University, Uchinada, Japan
| | - Yusuke Seki
- Department of Ophthalmology, Kanazawa Medical University, Uchinada, Japan
| | - Takuro Shirayama
- Department of Ophthalmology, Kanazawa Medical University, Uchinada, Japan
| | - Yuki Ukai
- Department of Ophthalmology, Kanazawa Medical University, Uchinada, Japan
| | - Hiroshi Sasaki
- Department of Ophthalmology, Kanazawa Medical University, Uchinada, Japan
| |
Collapse
|
2
|
Buhl L, Langer J, Kassumeh S, Kreutzer TC, Mayer WJ, Priglinger SG. Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery. Int J Ophthalmol 2023; 16:1231-1236. [PMID: 37602351 PMCID: PMC10398524 DOI: 10.18240/ijo.2023.08.07] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Accepted: 06/21/2023] [Indexed: 08/22/2023] Open
Abstract
AIM To evaluate the postoperative intraocular lens (IOL) rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL. METHODS In this retrospective case series, 32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter (D). A plate haptic toric IOL (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted in all eyes. The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity (BCVA). RESULTS Preoperative refractive astigmatism was 2.14±1.17 D, which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period (0.67±0.44 D at three months and 0.75±0.25 D at six months; for all groups: P<0.0001 compared to baseline). BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery (P=0.02). Mean IOL axis deviation from the target axis was 3.4°±2.9° after six to eight weeks and significantly decreased over time (2.4°±2.6° six months after surgery; P=0.04). In one patient IOL, re-alignment was performed. CONCLUSION Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery. The plate haptic toric IOL position and axis remain stable during the observation period of six months.
Collapse
Affiliation(s)
- Lara Buhl
- Department of Ophthalmology, University Hospital, LMU Munich, Munich 80336, Germany
| | - Julian Langer
- Department of Ophthalmology, University Hospital, LMU Munich, Munich 80336, Germany
| | - Stefan Kassumeh
- Department of Ophthalmology, University Hospital, LMU Munich, Munich 80336, Germany
| | - Thomas C Kreutzer
- Department of Ophthalmology, University Hospital, LMU Munich, Munich 80336, Germany
| | - Wolfgang J Mayer
- Department of Ophthalmology, University Hospital, LMU Munich, Munich 80336, Germany
| | | |
Collapse
|
3
|
Ichioka S, Ishida A, Takayanagi Y, Manabe K, Matsuo M, Tanito M, Tanito M. Roles of Toric intraocular Lens implantation on visual acuity and astigmatism in glaucomatous eyes treated with iStent and cataract surgery. BMC Ophthalmol 2022; 22:487. [PMCID: PMC9749338 DOI: 10.1186/s12886-022-02707-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 11/25/2022] [Indexed: 12/15/2022] Open
Abstract
Background To assess the efficacy of toric intraocular lenses (IOLs) in combined cataract and minimally invasive glaucoma surgery (MIGS), visual and refractive outcomes were compared between eyes implanted with non-toric and toric IOLs during iStent triple procedures. Methods In this retrospective study, open angle glaucoma eyes with preexisting corneal astigmatism of -1.5 diopter (D) or more and implanted with non-toric (n = 9) or toric (n = 9) IOLs were included. The main outcome measures were the intergroup difference in the uncorrected visual acuity (UCVA) and refractive astigmatism at 3 months postoperatively. Results Preoperatively, the logarithm of the minimum angle of resolution (logMAR) UCVAs and refractive astigmatism were equivalent between the groups. Postoperatively, the logMAR UCVA (non-toric, 0.45 ± 0.31; toric, 0.14 ± 0.15; P = 0.021) was significantly better and the refractive astigmatism (non-toric, -2.03 ± 0.63 D; toric, -0.67 ± 0.53 D; P = 0.0014) significantly less in the toric group. The toric group had postoperative improvements in the logMAR UCVA (-0.21, P = 0.020) and refractive astigmatism (+ 1.72 D, P = 0.0039). Vector analyses showed the postoperative centroid magnitude and confidence eclipses of refractive astigmatism was less in the toric group (0.47 D at 173°±0.73D) than the non-toric group (1.10 D at 2°±1.91D). Postoperatively, 78% of eyes in the toric group had 1.0 D or less refractive astigmatism compared with 11% in the non-toric group. Surgically induced astigmatism (non-toric, 0.18 D at 65°; toric, 0.29 D at 137°) did not differ between groups. Conclusion Use of toric IOLs is a reasonable option for better visual outcomes when the combined cataract and iStent surgery is performed in glaucomatous eyes with corneal astigmatism.
Collapse
Affiliation(s)
- Sho Ichioka
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Akiko Ishida
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Yuji Takayanagi
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Kaoru Manabe
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Masato Matsuo
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Masaki Tanito
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| | - Masaki Tanito
- grid.411621.10000 0000 8661 1590Department of Ophthalmology, Shimane University Faculty of Medicine, 89-1 Enya, Izumo, 693-8501 Shimane Japan
| |
Collapse
|
4
|
Effect of Toric Intraocular Lens Implantation on Visual Acuity and Astigmatism Status in Eyes Treated With Microhook Ab Interno Trabeculotomy. J Glaucoma 2021; 30:94-100. [PMID: 33031190 DOI: 10.1097/ijg.0000000000001705] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 09/22/2020] [Indexed: 11/26/2022]
Abstract
PRCIS Use of toric intraocular lenses is a reasonable option for better visual outcomes when a combined minimally invasive glaucoma surgery (MIGS) and cataract surgery is performed in eyes with corneal astigmatism. PURPOSE To assess the efficacy of toric intraocular lenses (IOLs) in combined cataract and MIGS, visual and refractive outcomes were compared between eyes implanted with nontoric and toric IOLs during microhook ab interno trabeculotomy triple procedures. METHODS Glaucomatous eyes with preexisting corneal astigmatism exceeding -1.5 D implanted with nontoric (n=10) or toric (n=10) IOLs were evaluated retrospectively. The uncorrected visual acuity (UCVA) and refractive astigmatism preoperatively and 3 months postoperatively were compared. RESULTS Preoperatively, the groups had similar logarithm of the minimum angle of resolution (logMAR) UCVAs and refractive astigmatism. Postoperatively, the logMAR UCVA (toric, 0.07±0.07; nontoric, 0.33±0.30; P=0.0020) was significantly better and the refractive astigmatism (toric, -0.63±0.56 D; nontoric, -1.53±0.74 D; P=0.0110) significantly less in the toric group. The toric group had postoperative improvements in the logMAR UCVA (-0.58, P=0.0039) and refractive astigmatism (+1.45 D, P=0.0195). Vector analyses showed the postoperative centroid magnitude of refractive astigmatism was less in the toric group (0.23 D at 83 degrees) than the nontoric group (1.03 D at 178 degrees). Postoperatively, 70% of eyes in the toric group had 1.0 D or less refractive astigmatism compared with 10% in the nontoric group. Surgically induced astigmatism (nontoric group, 0.62 D at 10 degrees; toric group, 0.50 D at 113 degrees) and intraocular pressure reduction (22% in both groups) did not differ between groups. CONCLUSIONS Better visual outcomes may be achieved with toric IOLs when a combined MIGS/cataract surgery is performed in eyes with corneal astigmatism.
Collapse
|
5
|
Refractive Status in Eyes Implanted with Toric and Nontoric Intraocular Lenses during Combined Cataract Surgery and Microhook Ab Interno Trabeculotomy. J Ophthalmol 2021; 2021:5545007. [PMID: 34136278 PMCID: PMC8179763 DOI: 10.1155/2021/5545007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 05/20/2021] [Indexed: 11/18/2022] Open
Abstract
Purpose To compare the refractive status between eyes implanted with toric and nontoric intraocular lenses (IOLs) during combined cataract surgery and microhook ab interno trabeculotomy (μLOT), a minimally invasive glaucoma surgery (MIGS). Methods Twenty eyes of 20 patients who had open-angle glaucoma, cataract, and preexisting regular corneal astigmatism exceeding 1.5 diopters (D) and underwent combined μLOT and phacoemulsification were recruited retrospectively. Ten eyes were implanted with a toric IOL and 10 eyes with a nontoric IOL. The primary outcomes were the uncorrected visual acuity (UCVA) and refractive cylinder at 3 months postoperatively. Results The mean UCVA of the toric IOL group (logarithm of the minimum angle of resolution (logMAR), 0.23 ± 0.25) was significantly better than that of the nontoric IOL group (logMAR, 0.45 ± 0.26) at 3 months postoperatively (p < 0.05). The mean absolute residual refractive cylinder of the nontoric IOL group (2.25 ± 0.62 D) was significantly greater than that of the toric IOL group (1.30 ± 0.68 D) (p < 0.05). Postoperatively, 60% of eyes in the toric IOL group and 10% in the nontoric IOL group had an absolute refractive astigmatism level of 1.5 D or less. Surgically induced astigmatism (0.77 ± 0.43 D for toric group and 0.60 ± 0.32 D for nontoric group) and IOP reduction (33.9 ± 15.6% for toric group and 29.4 ± 11.7% for nontoric group) were not different between groups. Conclusions Use of toric IOL during combined cataract surgery and μLOT is possible and better than not, but physician should prevent their patient of persisting residual astigmatism. The study was registered at https://www.umin.ac.jp/, and the clinical trial accession number is https://clinicaltrials.gov/ct2/show/UMIN000043141.
Collapse
|
6
|
Mustafa OM, Prescott C, Alsaleh F, Dzhaber D, Daoud YJ. Refractive and Visual Outcomes and Rotational Stability of Toric Intraocular Lenses in Eyes With and Without Previous Ocular Surgeries: A Longitudinal Study. J Refract Surg 2019; 35:781-788. [PMID: 31830294 DOI: 10.3928/1081597x-20191021-03] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Accepted: 10/21/2019] [Indexed: 12/22/2022]
Abstract
PURPOSE To evaluate visual and refractive outcomes and rotational stability of toric intraocular lens (IOL) implantation in eyes with previous ocular surgeries. METHODS This controlled, longitudinal cohort study included a total of 133 eyes (59 study cases with a history of corneal, vitreoretinal, and/or glaucoma surgery and 74 randomly selected controls without a history of ocular surgery) that had cataract and corneal astigmatism treated with toric IOL implantation. Postoperative outcomes were recorded at postoperative 1 month and 3 to 12 months. RESULTS Refractive prediction errors were within ±1.00 diopter (D) of target in 93.5% and 88.4% of the study cases at postoperative 1 month and 3 to 12 months, respectively. They were within ±0.50 D of target in 56.5% and 60.5% of the cases during the same follow-up intervals, respectively. Study cases showed statistically significantly inferior uncorrected distance visual acuity (UDVA) compared to controls at 1 month postoperatively (0.27 ± 0.24 and 0.17 ± 0.21 logMAR, respectively, P = .027) but not during the later follow-up (0.19 ± 0.19 and 0.16 ± 0.19 logMAR, respectively, P = .431). Corrected distance visual acuity (CDVA) was slightly lower in the study cases than in controls at 1 month postoperatively (0.13 ± 0.16 and 0.07 ± 0.14, respectively, P = .005) and subsequent follow-up months (0.10 ± 0.13 and 0.03 ± 0.10, respectively, P < .001). Of the examined study cases, 93.9% and 88.4% had IOL axes within 5° of intended axis at postoperative 1 month and 3 to 12 months, respectively. CONCLUSIONS Toric IOLs provided significant and sustained improvement in visual acuity and refraction in eyes with a history of prior ophthalmic surgery. Refractive outcomes achieved postoperatively were comparable to those in eyes without a prior history of ophthalmic surgery, although the rate of visual recovery may be different. [J Refract Surg. 2019;35(12):781-788.].
Collapse
|
7
|
Kolozsvári BL, Losonczy G, Pásztor D, Fodor M. Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series. BMC Ophthalmol 2017; 17:3. [PMID: 28086913 PMCID: PMC5234105 DOI: 10.1186/s12886-016-0397-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Accepted: 12/16/2016] [Indexed: 11/14/2022] Open
Abstract
Background Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are aware, there are no reported cases of toric IOL implantation in a vitrectomized eye with keratoconus nor of toric IOL implantation in patients with scleral-buckle-induced regular corneal astigmatism. Case presentation Two patients with myopia and high corneal astigmatism underwent cataract operation with toric IOL implantation after posterior segment surgery. Myopia and high astigmatism (>2.5 diopter) were caused by previous scleral buckling in one case and by keratoconus in the other case. Pre- and postoperative examinations during the follow-up of included uncorrected and spectacle corrected distance visual acuity (UCDVA/CDVA), automated kerato-refractometry (Topcon), Pentacam HR, IOL Master (Zeiss) axial length measurements and fundus optical coherence tomography (Zeiss). One year postoperatively, the UCDVA and CDVA were 20/25 and 20/20 in both cases, respectively. The absolute residual refractive astigmatism was 1.0 and 0.75 Diopters, respectively. The IOL rotation was within 3° in both eyes, therefore IOL repositioning was not necessary. Complications were not observed in our cases. Conclusion These cases demonstrate that toric IOL implantation is a predictable and safe method for the correction of high corneal astigmatism in complicated cases with different origins. Irregular corneal astigmatism in keratoconus or scleral-buckle-induced regular astigmatisms can be equally well corrected with the use of toric IOL during cataract surgery. Previous scleral buckling or pars plana vitrectomy seem to have no impact on the success of the toric IOL implantation, even in keratoconus. IOL rotational stability and refractive predictability in patients with a previous vitreoretinal surgery can be as good as in uncomplicated cases.
Collapse
Affiliation(s)
- Bence L Kolozsvári
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98, H-4012, Debrecen, Hungary
| | - Gergely Losonczy
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98, H-4012, Debrecen, Hungary
| | - Dorottya Pásztor
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98, H-4012, Debrecen, Hungary
| | - Mariann Fodor
- Department of Ophthalmology, Faculty of Medicine, University of Debrecen, Nagyerdei krt. 98, H-4012, Debrecen, Hungary.
| |
Collapse
|
8
|
Kessel L, Andresen J, Tendal B, Erngaard D, Flesner P, Hjortdal J. Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery: A Systematic Review and Meta-analysis. Ophthalmology 2015; 123:275-286. [PMID: 26601819 DOI: 10.1016/j.ophtha.2015.10.002] [Citation(s) in RCA: 216] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Revised: 10/01/2015] [Accepted: 10/01/2015] [Indexed: 10/22/2022] Open
Abstract
TOPIC We performed a systematic review and meta-analysis to evaluate the benefit and harms associated with implantation of toric intraocular lenses (IOLs) during cataract surgery. Outcomes were postoperative uncorrected distance visual acuity (UCDVA) and distance spectacle independence. Harms were evaluated as surgical complications and residual astigmatism. CLINICAL RELEVANCE Postoperative astigmatism is an important cause of suboptimal UCDVA and need for distance spectacles. Toric IOLs may correct for preexisting corneal astigmatism at the time of surgery. METHODS We performed a systematic literature search in the Embase, PubMed, and CENTRAL databases within the Cochrane Library. We included randomized clinical trials (RCTs) if they compared toric with non-toric IOL implantation (± relaxing incision) in patients with regular corneal astigmatism and age-related cataracts. We assessed the risk of bias using the Cochrane Risk of Bias tool. We assessed the quality of evidence across studies using the GRADE profiler software (available at: www.gradeworkinggroup.org). RESULTS We included 13 RCTs with 707 eyes randomized to toric IOLs and 706 eyes randomized to non-toric IOLs; 225 eyes had a relaxing incision. We found high-quality evidence that UCDVA was better in the toric IOL group (logarithm of the minimum angle of resolution [logMAR] mean difference, -0.07; 95% confidence interval [CI], -0.10 to -0.04) and provided greater spectacle independence (risk ratio [RR], 0.51; 95% CI, 0.36-0.71) and moderate quality evidence that toric IOL implantation was not associated with an increased risk of complications (RR, 1.73; 95% CI, 0.60-5.04). Residual astigmatism was lower in the toric IOL group than in the non-toric IOL plus relaxing incision group (mean difference, 0.37 diopter [D]; 95% CI, -0.55 to -0.19). CONCLUSIONS We found that toric IOLs provided better UCDVA, greater spectacle independence, and lower amounts of residual astigmatism than non-toric IOLs even when relaxing incisions were used.
Collapse
Affiliation(s)
- Line Kessel
- Department of Ophthalmology, Rigshospitalet - Glostrup, Glostrup, Denmark; National Danish Medicines and Health Authorities, Copenhagen, Denmark.
| | | | - Britta Tendal
- National Danish Medicines and Health Authorities, Copenhagen, Denmark; The Nordic Cochrane Center, Copenhagen, Denmark
| | - Ditte Erngaard
- Department of Ophthalmology, Næstved Hospital, Næstved, Denmark
| | | | - Jesper Hjortdal
- Department of Ophthalmology, Aarhus University Hospital NBG, Aarhus, Denmark
| |
Collapse
|
9
|
Shao Y, Dong LJ, Zhang Y, Liu H, Hu BJ, Liu JP, Li XR. Surgical induced astigmatism correlated with corneal pachymetry and intraocular pressure: transconjunctival sutureless 23-gauge versus 20-gauge sutured vitrectomy in diabetes mellitus. Int J Ophthalmol 2015; 8:528-33. [PMID: 26086002 DOI: 10.3980/j.issn.2222-3959.2015.03.16] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Accepted: 12/08/2014] [Indexed: 11/02/2022] Open
Abstract
AIM To determine the difference of surgical induced astigmatism between conventional 20-gauge sutured vitrectomy and 23-gauge transconjunctival sutureless vitrectomy, and the influence of corneal pachymetry and intraocular pressure (IOP) on surgical induced astigmatism in diabetic patients. METHODS This retrospective, consecutive case series consisted of 40 eyes of 38 diabetic subjects who underwent either 20-gauge or 23-gauge vitrectomy. The corneal curvature and thickness were measured with Scheimpflug imaging before surgery and 1wk; 1, 3mo after surgery. We compared the surgical induced astigmatism (SIA) on the true net power in 23-gauge group with that in 20-gauge group. We determined the correlation between corneal thickness change ratio, IOP and SIA measured by Pentacam. RESULTS The mean SIAs were 1.082±0.085 D (mean±SEM), 0.689±0.070 D and 0.459±0.063 D at postoperative 1wk; 1, 3mo respectively in diabetic subjects. The vitrectomy induced astigmatisms were declined significantly with time (F 2,36=33.629, P=0.000) postoperatively. The 23-gauge surgery group induced significantly less astigmatism than 20-gauge surgery group (F -1,37=11.046, P=0.020). Corneal thickness in diabetes elevated after surgery (F 3,78=10.532, P=0.000). The linear regression analysis at postoperatively 1wk went as: SIA=-4.519+4.931 change ratio (Port3) +0.026 IOP (R(2)=0.46, P=0.000), whereas the rate of corneal thickness change and IOP showed no correlation with the change of astigmatism at postoperatively 1 and 3mo. CONCLUSION There are significant serial changes in both 20-gauge and 23-gauge group in diabetic subjects. 23-gauge induce less astigmatism than 20-gauge and become stable more rapidly than 20-gauge. The elevation of corneal thickness and IOP was associated with increased astigmatim at the early postoperative stage both in 23-gauge and 20-gauge surgery group.
Collapse
Affiliation(s)
- Yan Shao
- Tianjin Medical University Eye Hospital; Tianjin Medical University Eye Institute; The College of Optometry & Ophthalmology, Tianjin 300384, China
| | - Li-Jie Dong
- Tianjin Medical University Eye Hospital; Tianjin Medical University Eye Institute; The College of Optometry & Ophthalmology, Tianjin 300384, China
| | - Yan Zhang
- Tianjin Medical University Eye Hospital; Tianjin Medical University Eye Institute; The College of Optometry & Ophthalmology, Tianjin 300384, China
| | - Hui Liu
- Tianjin Medical University Eye Hospital; Tianjin Medical University Eye Institute; The College of Optometry & Ophthalmology, Tianjin 300384, China
| | - Bo-Jie Hu
- Tianjin Medical University Eye Hospital; Tianjin Medical University Eye Institute; The College of Optometry & Ophthalmology, Tianjin 300384, China
| | - Ju-Ping Liu
- Tianjin Medical University Eye Hospital; Tianjin Medical University Eye Institute; The College of Optometry & Ophthalmology, Tianjin 300384, China
| | - Xiao-Rong Li
- Tianjin Medical University Eye Hospital; Tianjin Medical University Eye Institute; The College of Optometry & Ophthalmology, Tianjin 300384, China
| |
Collapse
|
10
|
STABILITY OF THE ACRYSOF TORIC INTRAOCULAR LENS IN COMBINED CATARACT SURGERY AND TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY. Retina 2015; 35:1065-71. [DOI: 10.1097/iae.0000000000000440] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
11
|
Oh JH, Na J, Kim SW, Oh J, Huh K. Risk factors for posterior synechiae of the iris after 23-gauge phacovitrectomy. Int J Ophthalmol 2014; 7:843-9. [PMID: 25349804 DOI: 10.3980/j.issn.2222-3959.2014.05.19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Accepted: 03/04/2014] [Indexed: 11/02/2022] Open
Abstract
AIM To identify risk factors for the development of posterior synechiae of the iris (PSI) after 23-gauge phacovitrectomy. METHODS A retrospective chart review was performed in consecutive Asian patients treated with 23-gauge phacovitrectomy with a 3-piece intraocular lens (IOL) or a single-piece 4 haptics IOL. RESULTS A total of 263 eyes from 242 patients were included in the study. Postoperative PSI was identified in 16 (6.1%) eyes. In multivariate analysis, C3F8 gas tamponade, oil tamponade, and long operation time were significantly associated with PSI formation. There was no difference in the incidence of PSI between the groups using two different types of IOL (P=0.779). CONLUSION C3F8 gas or oil tamponade and long operation time increased the incidence of PSI after 23-gauge phacovitrectomy. The single-piece 4 haptics IOL, in lieu of a 3-piece IOL, may be inserted into the capsular bag with a comparable incidence of PSI.
Collapse
Affiliation(s)
- Jong-Hyun Oh
- Department of Ophthalmology, Dongguk University Ilsan Hospital, Goyang 410-773, South Korea
| | - Jaehoon Na
- Department of Ophthalmology, Korea University College of Medicine, Seoul 136-705, South Korea
| | - Seong-Woo Kim
- Department of Ophthalmology, Korea University College of Medicine, Seoul 136-705, South Korea
| | - Jaeryung Oh
- Department of Ophthalmology, Korea University College of Medicine, Seoul 136-705, South Korea
| | - Kuhl Huh
- Department of Ophthalmology, Korea University College of Medicine, Seoul 136-705, South Korea
| |
Collapse
|
12
|
Abstract
Vitreoretinal surgery has recently undergone remarkable developments. The introduction of micro-incision vitrectomy surgery using 25- and 23-gauge techniques has led to minimally invasive, faster, safer, and more accurate surgeries. Similarly, intraocular illumination and observation systems have advanced from light pipes to chandelier illumination, slit illumination, wide-angle viewing systems, and intraocular endoscopes. Compared to observation via the cornea and optic media, vitreous surgery using an endoscope is extremely useful, as the endoscope is inserted directly into the eye, circumventing the difficulties of corneal clouding and small pupil diameters. Furthermore, there are no blind spots after surgery. We here discuss the advantages of intraocular endoscope use, the current state of endoscopy-guided vitreoretinal surgery, and its future prospects.
Collapse
Affiliation(s)
- Shinichi Kawashima
- Department of Ophthalmology, School of Medicine, Tsurumi University, 2-1-3 Tsurumi Tsurumi-ku, Yokohama-shi, Kanagawa, 2308501, Japan
| | | | | |
Collapse
|
13
|
Inoue M, Noda T, Ohnuma K, Bissen-Miyajima H, Hirakata A. Quality of image of grating target placed in model eye and observed through toric intraocular lenses. Am J Ophthalmol 2013; 155:243-252.e1. [PMID: 23036568 DOI: 10.1016/j.ajo.2012.07.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2012] [Revised: 07/11/2012] [Accepted: 07/12/2012] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the quality of an image of a grating target placed in a model eye and viewed through implanted toric intraocular lenses (IOLs). DESIGN Laboratory investigation. METHODS Toric IOLs, SN6AT5 with a cylinder power of 3.0 diopters (3.0 D, Alcon), ST6AT9 (6.0 D, Alcon), 311T5 (3.0 D, HOYA), or 311T9 (6.0 D, HOYA), were placed in a fluid-filled model eye. A United States Air Force test target was placed internally on the posterior surface of the model eye. A flat contact lens or a wide-angle contact lens was placed on the cornea. The contrast and length of the grating targets perpendicular (vertical) or parallel (horizontal) to the flat meridian of the toric IOL were compared with those obtained through aspheric IOLs. RESULTS The contrast of the targets viewed through the flat contact lens and toric IOLs in the vertical direction was significantly lower than that viewed through the aspheric IOL at 16 cycle/mm (SN6AT9, P=.002; SN6AT5, P=.028; 311T9, P=.002; 311T5, P =.011) but not with the wide-angle viewing lens at 16, 32, and 64 cycle/mm. The vertical length of the target with a flat contact lens was longer and the horizontal length was shorter than that through the aspheric IOL by 1% to 3% with the SN6AT5 and 311T5 IOLs and by 3% to 5% with the SN6AT9 and 311T9 IOLs. However, the vertical and horizontal lengths were not significantly different through the wide-viewing lens. CONCLUSION Toric IOLs affect the contrast of a grating target viewed through a flat contact lens but not through a wide-angle viewing lens. The wide-angle viewing system is not influenced by cylindrical aberrations.
Collapse
Affiliation(s)
- Makoto Inoue
- Kyorin Eye Center, Kyorin University School of Medicine, Tokyo, Japan.
| | | | | | | | | |
Collapse
|
14
|
Olson JL, Velez-Montoya R, Erlanger M. Ocular biocompatibility of nitinol intraocular clips. Invest Ophthalmol Vis Sci 2012; 53:354-60. [PMID: 22064995 DOI: 10.1167/iovs.11-8496] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To evaluate the tolerance and biocompatibility of a preformed nitinol intraocular clip in an animal model after anterior segment surgery. METHODS Yucatan mini-pigs were used. A 30-gauge prototype injector was used to attach a shape memory nitinol clip to the iris of five pigs. Another five eyes received conventional polypropylene suture with a modified Seipser slip knot. The authors compared the surgical time of each technique. All eyes underwent standard full-field electroretinogram at baseline and 8 weeks after surgery. The animals were euthanized and eyes collected for histologic analysis after 70 days (10 weeks) postsurgery. The corneal thickness, corneal endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram parameters were compared between the groups. A two sample t-test for means and a P value of 0.05 were use for assessing statistical differences between measurements. RESULTS The injection of the nitinol clip was 15 times faster than conventional suturing. There were no statistical differences between the groups for corneal thickness, endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram measurements. CONCLUSIONS The nitinol clip prototype is well tolerated and showed no evidence of toxicity in the short-term. The injectable delivery system was faster and technically less challenging than conventional suture techniques.
Collapse
Affiliation(s)
- Jeffrey L Olson
- Department of Ophthalmology, University of Colorado Health and Science Center, Rocky Mountain Lions Eye Institute, University of Colorado School of Medicine, Aurora, Colorado, USA.
| | | | | |
Collapse
|