1
|
Molway MJ, Bales-Shaffer L, Ranta K, Ball J, Sparling E, Prince M, Cocking D, Basler D, Murphy M, Kidd BE, Gafar AT, Porter J, Albin K, Rosen MS, Chekmenev EY, Michael Snow W, Barlow MJ, Goodson BM. Dramatic improvement in the "Bulk" hyperpolarization of 131Xe via spin exchange optical pumping probed using in situ low-field NMR. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 354:107521. [PMID: 37487304 DOI: 10.1016/j.jmr.2023.107521] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 07/04/2023] [Accepted: 07/06/2023] [Indexed: 07/26/2023]
Abstract
We report on hyperpolarization of quadrupolar (I=3/2) 131Xe via spin-exchange optical pumping. Observations of the 131Xe polarization dynamics via in situ low-field NMR show that the estimated alkali-metal/131Xe spin-exchange rates can be large enough to compete with 131Xe spin relaxation. 131Xe polarization up to 7.6±1.5% was achieved in ∼8.5×1020 spins-a ∼100-fold improvement in the total spin angular momentum-potentially enabling various applications, including: measurement of spin-dependent neutron-131Xe s-wave scattering; sensitive searches for time-reversal violation in neutron-131Xe interactions beyond the Standard Model; and surface-sensitive pulmonary MRI.
Collapse
Affiliation(s)
- Michael J Molway
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - Liana Bales-Shaffer
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - Kaili Ranta
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - James Ball
- School of Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK
| | - Eleanor Sparling
- School of Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK
| | - Mia Prince
- School of Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK
| | - Daniel Cocking
- School of Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK
| | - Dustin Basler
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - Megan Murphy
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - Bryce E Kidd
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - Abdulbasit Tobi Gafar
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - Justin Porter
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - Kierstyn Albin
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA
| | - Matthew S Rosen
- A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Boston 02129, MA, USA; Department of Physics, Harvard University, Cambridge 02138, MA, USA
| | - Eduard Y Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Karmanos Cancer Institute (KCI), Wayne State University, Detroit 48202, MI, USA; Russian Academy of Sciences, Leninskiy Prospekt 14, 119991 Moscow, Russia
| | - W Michael Snow
- Department of Physics, Indiana University, Bloomington, IN, USA
| | - Michael J Barlow
- School of Medicine, University of Nottingham, Queens Medical Centre, Nottingham, UK
| | - Boyd M Goodson
- School of Chemical and Biomolecular Sciences, Southern Illinois University, Carbondale 62901, IL, USA.
| |
Collapse
|
2
|
Abstract
The capability of magnetic induction to transmit signals in attenuating environments has recently gained significant research interest. The wave aspect—magnetoinductive (MI) waves—has been proposed for numerous applications in RF-challenging environments, such as underground/underwater wireless networks, body area networks, and in-vivo medical diagnosis and treatment applications, to name but a few, where conventional electromagnetic waves have a number of limitations, most notably losses. To date, the effects of eddy currents inside the dissipative medium have not been characterised analytically. Here we propose a comprehensive circuit model of coupled resonators in a homogeneous dissipative medium, that takes into account all the electromagnetic effects of eddy currents, and, thereby, derive a general dispersion equation for the MI waves. We also report laboratory experiments to confirm our findings. Our work will serve as a fundamental model for design and analysis of every system employing MI waves or more generally, magnetically-coupled circuits in attenuating media.
Collapse
|
3
|
Zhou X, He C, Liu M, Chen Q, Zhang L, Xu X, Xu H, Qian Y, Yu F, Wu Y, Han Y, Xiao B, Tang J, Hu H. Self-assembly of hyaluronic acid-mediated tumor-targeting theranostic nanoparticles. Biomater Sci 2021; 9:2221-2229. [PMID: 33507179 DOI: 10.1039/d0bm01855d] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Theranostic nanoparticles (NPs) have emerged as promising candidates for cancer diagnosis and treatment. Manganese dioxide (MnO2)-based NPs are potential contrast agents with excellent paramagnetic property and biocompatibility, exhibiting satisfactory magnetic resonance imaging (MRI) effects and biological safety. Recently, hyaluronic acid (HA) has gained increasing interest due to its tumor-targeting ability, which can improve the tumor affinity of manganese dioxide (MnO2)-based NPs. In this study, HA-coated and albumin (BSA)-templated MnO2 and polydopamine hybrid nanoparticles (HMDNs) with tumor-targeting and superior imaging capability were fabricated via modifying the nanoparticles prepared by integrating dopamine polymerization and MnO2 biomineralization. The modification was found to enhance the cellular uptake of HMDNs by cancer cells. The prepared HMDN had high MRI contrasting capability with a longitudinal relaxivity of 22.2 mM-1 s-1 and strong photothermal therapy (PTT) effects with nearly complete tumor ablation under laser irradiation in vivo. HMDNs also showed effective clearance through kidneys, with no toxicity to important tissues. Therefore, HMDNs with superior imaging and PTT capability presented a new method to prepare tumor-targeting multifunctional nanotheranostics.
Collapse
Affiliation(s)
- Xiaoxuan Zhou
- Department of Radiology, Sir Run Run Shaw Hospital (SRRSH) of School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310016, China.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Zhang X, Jing Q, Ao S, Schneider GF, Kireev D, Zhang Z, Fu W. Ultrasensitive Field-Effect Biosensors Enabled by the Unique Electronic Properties of Graphene. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1902820. [PMID: 31592577 DOI: 10.1002/smll.201902820] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 09/08/2019] [Indexed: 05/20/2023]
Abstract
This review provides a critical overview of current developments on nanoelectronic biochemical sensors based on graphene. Composed of a single layer of conjugated carbon atoms, graphene has outstanding high carrier mobility and low intrinsic electrical noise, but a chemically inert surface. Surface functionalization is therefore crucial to unravel graphene sensitivity and selectivity for the detection of targeted analytes. To achieve optimal performance of graphene transistors for biochemical sensing, the tuning of the graphene surface properties via surface functionalization and passivation is highlighted, as well as the tuning of its electrical operation by utilizing multifrequency ambipolar configuration and a high frequency measurement scheme to overcome the Debye screening to achieve low noise and highly sensitive detection. Potential applications and prospectives of ultrasensitive graphene electronic biochemical sensors ranging from environmental monitoring and food safety, healthcare and medical diagnosis, to life science research, are presented as well.
Collapse
Affiliation(s)
- Xiaoyan Zhang
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, P. R. China
- Leiden Institute of Chemistry, Leiden University, Einsteinweg 55, 2333CC, Leiden, The Netherlands
| | - Qiushi Jing
- School of Materials Science and Engineering, Tsinghua University, Shaw Technical Science Building, Haidian District, Beijing, 100084, P. R. China
| | - Shen Ao
- School of Materials Science and Engineering, Tsinghua University, Shaw Technical Science Building, Haidian District, Beijing, 100084, P. R. China
| | - Grégory F Schneider
- Leiden Institute of Chemistry, Leiden University, Einsteinweg 55, 2333CC, Leiden, The Netherlands
| | - Dmitry Kireev
- Department of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX, 78757, USA
| | - Zhengjun Zhang
- School of Materials Science and Engineering, Tsinghua University, Shaw Technical Science Building, Haidian District, Beijing, 100084, P. R. China
| | - Wangyang Fu
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, P. R. China
| |
Collapse
|
5
|
Skinner JG, Ranta K, Whiting N, Coffey AM, Nikolaou P, Rosen MS, Chekmenev EY, Morris PG, Barlow MJ, Goodson BM. High Xe density, high photon flux, stopped-flow spin-exchange optical pumping: Simulations versus experiments. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 312:106686. [PMID: 32006793 PMCID: PMC7436892 DOI: 10.1016/j.jmr.2020.106686] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Accepted: 01/07/2020] [Indexed: 05/13/2023]
Abstract
Spin-exchange optical pumping (SEOP) can enhance the NMR sensitivity of noble gases by up to five orders of magnitude at Tesla-strength magnetic fields. SEOP-generated hyperpolarised (HP) 129Xe is a promising contrast agent for lung imaging but an ongoing barrier to widespread clinical usage has been economical production of sufficient quantities with high 129Xe polarisation. Here, the 'standard model' of SEOP, which was previously used in the optimisation of continuous-flow 129Xe polarisers, is modified for validation against two Xe-rich stopped-flow SEOP datasets. We use this model to examine ways to increase HP Xe production efficiency in stopped-flow 129Xe polarisers and provide further insight into the underlying physics of Xe-rich stopped-flow SEOP at high laser fluxes.
Collapse
Affiliation(s)
- Jason G Skinner
- Division of Respiratory Medicine, School of Medicine, Queen's Medical Centre, University of Nottingham, Nottingham, NG7 2UH, UK
| | - Kaili Ranta
- Department of Chemistry and Biochemistry, Southern Illinois University Carbondale, Carbondale, IL, 62901, USA
| | - Nicholas Whiting
- Department of Physics & Astronomy and Department of Molecular & Cellular Biosciences, Rowan University, Glassboro, NJ 08028, USA
| | - Aaron M Coffey
- Vanderbilt University Institute of Imaging Science (VUIIS), Department of Radiology and Radiological Sciences, Vanderbilt-Ingram Cancer Center (VICC), Department of Biomedical Engineering, Department of Physics and Astronomy, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
| | | | - Matthew S Rosen
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, 149 13th Street, Charlestown, MA 02129, USA; Department of Radiology, Harvard Medical School, Boston, MA 02115, USA; Department of Physics, Harvard University, Cambridge, MA 02138, USA
| | - Eduard Y Chekmenev
- Russian Academy of Sciences, Leninskiy Prospekt 14, 119991 Moscow, Russia; Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI, 48202, United States
| | - Peter G Morris
- Sir Peter Mansfield Imaging Centre, School of Physics & Astronomy, University of Nottingham, Nottingham, NG7 2RD, UK
| | - Michael J Barlow
- Division of Respiratory Medicine, School of Medicine, Queen's Medical Centre, University of Nottingham, Nottingham, NG7 2UH, UK
| | - Boyd M Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University Carbondale, Carbondale, IL, 62901, USA.
| |
Collapse
|
6
|
Gjesteby L, Cong W, Yang Q, Qian C, Wang G. Simultaneous Emission-Transmission Tomography in an MRI Hardware Framework. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2018; 2:326-336. [PMID: 29998213 PMCID: PMC6037318 DOI: 10.1109/trpms.2018.2835312] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Multi-modality imaging is essential for diagnosis and therapy in challenging cases. A Holy Grail of medical imaging is a hybrid imaging system combining computed tomography (CT), nuclear imaging, and magnetic resonance imaging (MRI) to deliver registered morphological, functional, and cellular/molecular information simultaneously and quantitatively for precision medicine. Recently, a unique imaging approach was demonstrated that combines nuclear imaging with polarized radiotracers and MRI-based spatial encoding. The detection scheme exploits the directional preference of γ-rays emitted from the polarized nuclei, and the result is a concentration image with resolution that can outperform standard nuclear imaging at a sensitivity significantly higher than that of MRI. However, the method does not calculate the attenuation image. Here we propose to obtain MRI-modulated γ-ray data for simultaneous image reconstruction of emission and transmission parameters, which could serve as a stepping stone toward simultaneous CT-SPECT-MRI. This method acquires synchronized datasets to provide insight into morphological features and molecular activities with accurate spatiotemporal registration. We present a complete overview of the system design and the formulation for tomographic reconstruction when the distribution of polarized radiotracers is either global or limited to a region of interest (ROI). Numerical results support the feasibility of our approach and suggest further research topics.
Collapse
Affiliation(s)
- Lars Gjesteby
- Biomedical Imaging Center, Department of Biomedical Engineering at Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Wenxiang Cong
- Biomedical Imaging Center, Department of Biomedical Engineering at Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Qingsong Yang
- Biomedical Imaging Center, Department of Biomedical Engineering at Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Chunqi Qian
- Department of Radiology at Michigan State University, East Lansing, MI, USA
| | - Ge Wang
- Biomedical Imaging Center, Department of Biomedical Engineering at Rensselaer Polytechnic Institute, Troy, NY, USA
| |
Collapse
|
7
|
Kern AL, Vogel-Claussen J. Hyperpolarized gas MRI in pulmonology. Br J Radiol 2018; 91:20170647. [PMID: 29271239 PMCID: PMC5965996 DOI: 10.1259/bjr.20170647] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 12/12/2017] [Accepted: 12/08/2017] [Indexed: 01/20/2023] Open
Abstract
Lung diseases have a high prevalence amongst the world population and their early diagnosis has been pointed out to be key for successful treatment. However, there is still a lack of non-invasive examination methods with sensitivity to early, local deterioration of lung function. Proton-based lung MRI is particularly challenging due to short T2* times and low proton density within the lung tissue. Hyperpolarized gas MRI is aan emerging technology providing a richness of methodologies which overcome the aforementioned problems. Unlike proton-based MRI, lung MRI of hyperpolarized gases may rely on imaging of spins in the lung's gas spaces or inside the lung tissue and thereby add substantial value and diagnostic potential to lung MRI. This review article gives an introduction to the MR physics of hyperpolarized media and presents the current state of hyperpolarized gas MRI of 3Headvasd and 129Xe in pulmonology. Key applications, ranging from static and dynamic ventilation imaging as well as oxygen-pressure mapping to 129Xe dissolved-phase imaging and spectroscopy are presented. Hyperpolarized gas MRI is compared to alternative examination methods based on MRI and future directions of hyperpolarized gas MRI are discussed.
Collapse
|
8
|
Zhou Z, Yu J, Colell JFP, Laasner R, Logan A, Barskiy D, Schepin R, Chekmenev EY, Blum V, Warren WS, Theis T. Long-Lived 13C 2 Nuclear Spin States Hyperpolarized by Parahydrogen in Reversible Exchange at Microtesla Fields. J Phys Chem Lett 2017; 8:3008-3014. [PMID: 28594557 PMCID: PMC5580346 DOI: 10.1021/acs.jpclett.7b00987] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Parahydrogen is an inexpensive and readily available source of hyperpolarization used to enhance magnetic resonance signals by up to four orders of magnitude above thermal signals obtained at ∼10 T. A significant challenge for applications is fast signal decay after hyperpolarization. Here we use parahydrogen-based polarization transfer catalysis at microtesla fields (first introduced as SABRE-SHEATH) to hyperpolarize 13C2 spin pairs and find decay time constants of 12 s for magnetization at 0.3 mT, which are extended to 2 min at that same field, when long-lived singlet states are hyperpolarized instead. Enhancements over thermal at 8.5 T are between 30 and 170 fold (0.02 to 0.12% polarization). We control the spin dynamics of polarization transfer by choice of microtesla field, allowing for deliberate hyperpolarization of either magnetization or long-lived singlet states. Density functional theory calculations and experimental evidence identify two energetically close mechanisms for polarization transfer: First, a model that involves direct binding of the 13C2 pair to the polarization transfer catalyst and, second, a model transferring polarization through auxiliary protons in substrates.
Collapse
Affiliation(s)
- Zijian Zhou
- Department of Chemistry, Duke University, Durham NC 27708, United States
| | - Jin Yu
- Department of Chemistry, Duke University, Durham NC 27708, United States
| | | | - Raul Laasner
- Department of Mechanical Engineering and Materials Science, Duke University, Durham NC 27708, United States
| | - Angus Logan
- Department of Chemistry, Duke University, Durham NC 27708, United States
| | - Danila Barskiy
- Departments of Radiology, Biomedical Engineering and Physics, Vanderbilt University, Institute of Imaging Science (VUIIS), Nashville, TN 37232, United States
| | - Roman Schepin
- Departments of Radiology, Physics and Biomedical Engineering, Duke University, Durham NC 27708, United States
| | - Eduard Y. Chekmenev
- Departments of Radiology, Physics and Biomedical Engineering, Duke University, Durham NC 27708, United States
| | - Volker Blum
- Department of Chemistry, Duke University, Durham NC 27708, United States
- Department of Mechanical Engineering and Materials Science, Duke University, Durham NC 27708, United States
| | - Warren S. Warren
- Department of Chemistry, Duke University, Durham NC 27708, United States
- Departments of Radiology, Physics and Biomedical Engineering, Duke University, Durham NC 27708, United States
| | - Thomas Theis
- Department of Chemistry, Duke University, Durham NC 27708, United States
- Corresponding Author: To whom correspondence should be addressed.
| |
Collapse
|
9
|
Delivering strong 1H nuclear hyperpolarization levels and long magnetic lifetimes through signal amplification by reversible exchange. Proc Natl Acad Sci U S A 2017; 114:E3188-E3194. [PMID: 28377523 DOI: 10.1073/pnas.1620457114] [Citation(s) in RCA: 107] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Hyperpolarization turns typically weak NMR and MRI responses into strong signals so that ordinarily impractical measurements become possible. The potential to revolutionize analytical NMR and clinical diagnosis through this approach reflect this area's most compelling outcomes. Methods to optimize the low-cost parahydrogen-based approach signal amplification by reversible exchange with studies on a series of biologically relevant nicotinamides and methyl nicotinates are detailed. These procedures involve specific 2H labeling in both the agent and catalyst and achieve polarization lifetimes of ca 2 min with 50% polarization in the case of methyl-4,6-d2 -nicotinate. Because a 1.5-T hospital scanner has an effective 1H polarization level of just 0.0005% this strategy should result in compressed detection times for chemically discerning measurements that probe disease. To demonstrate this technique's generality, we exemplify further studies on a range of pyridazine, pyrimidine, pyrazine, and isonicotinamide analogs that feature as building blocks in biochemistry and many disease-treating drugs.
Collapse
|
10
|
Colell JP, Logan AWJ, Zhou Z, Shchepin RV, Barskiy DA, Ortiz GX, Wang Q, Malcolmson SJ, Chekmenev EY, Warren WS, Theis T. Generalizing, Extending, and Maximizing Nitrogen-15 Hyperpolarization Induced by Parahydrogen in Reversible Exchange. THE JOURNAL OF PHYSICAL CHEMISTRY. C, NANOMATERIALS AND INTERFACES 2017; 121:6626-6634. [PMID: 28392884 PMCID: PMC5378067 DOI: 10.1021/acs.jpcc.6b12097] [Citation(s) in RCA: 106] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Revised: 01/13/2017] [Indexed: 05/17/2023]
Abstract
Signal Amplification by Reversible Exchange (SABRE) is a fast and convenient NMR hyperpolarization method that uses cheap and readily available para-hydrogen as a hyperpolarization source. SABRE can hyperpolarize protons and heteronuclei. Here we focus on the heteronuclear variant introduced as SABRE-SHEATH (SABRE in SHield Enables Alignment Transfer to Heteronuclei) and nitrogen-15 targets in particular. We show that 15N-SABRE works more efficiently and on a wider range of substrates than 1H-SABRE, greatly generalizing the SABRE approach. In addition, we show that nitrogen-15 offers significantly extended T1 times of up to 12 minutes. Long T1 times enable higher hyperpolarization levels but also hold the promise of hyperpolarized molecular imaging for several tens of minutes. Detailed characterization and optimization are presented, leading to nitrogen-15 polarization levels in excess of 10% on several compounds.
Collapse
Affiliation(s)
- Johannes
F. P. Colell
- Department
of Chemistry, Duke University, Durham, North Carolina 27708, United States
| | - Angus W. J. Logan
- Department
of Chemistry, Duke University, Durham, North Carolina 27708, United States
| | - Zijian Zhou
- Department
of Chemistry, Duke University, Durham, North Carolina 27708, United States
| | - Roman V. Shchepin
- Vanderbilt
University Institute of Imaging Science (VUIIS), Department of Radiology,
Department of Biomedical Engineering, Vanderbilt Ingram Cancer Center
(VICC), Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Danila A. Barskiy
- Vanderbilt
University Institute of Imaging Science (VUIIS), Department of Radiology,
Department of Biomedical Engineering, Vanderbilt Ingram Cancer Center
(VICC), Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Gerardo X. Ortiz
- Department
of Chemistry, Duke University, Durham, North Carolina 27708, United States
| | - Qiu Wang
- Department
of Chemistry, Duke University, Durham, North Carolina 27708, United States
| | - Steven J. Malcolmson
- Department
of Chemistry, Duke University, Durham, North Carolina 27708, United States
| | - Eduard Y. Chekmenev
- Vanderbilt
University Institute of Imaging Science (VUIIS), Department of Radiology,
Department of Biomedical Engineering, Vanderbilt Ingram Cancer Center
(VICC), Vanderbilt University, Nashville, Tennessee 37232, United States
- Russian
Academy of Sciences, Moscow, Russia
| | - Warren S. Warren
- Department
of Chemistry, Duke University, Durham, North Carolina 27708, United States
- Departments
of Physics, Radiology and Biomedical Engineering, Duke University, Durham, North Carolina 27707, United States
- E-mail:
| | - Thomas Theis
- Department
of Chemistry, Duke University, Durham, North Carolina 27708, United States
- E-mail:
| |
Collapse
|
11
|
Schober O, Dössel O, Ermert H, Requardt H, Ziegler S, Adam G. [Imaging in clinic and research: contribution to individualized medicine?]. Nuklearmedizin 2017. [PMID: 29533421 DOI: 10.3413/2017-05-0002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
12
|
|