1
|
Pallapothu B, Priyadarshi M, Singh P, Kumar S, Chaurasia S, Basu S. T-Piece resuscitator versus self-inflating bag for delivery room resuscitation in preterm neonates: a randomized controlled trial. Eur J Pediatr 2023; 182:5565-5576. [PMID: 37792092 DOI: 10.1007/s00431-023-05230-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 09/15/2023] [Accepted: 09/18/2023] [Indexed: 10/05/2023]
Abstract
The establishment of adequate ventilation is the cornerstone of neonatal resuscitation in the delivery room (DR). This parallel-group, accessor-blinded randomized controlled trial compared the changes in peripheral oxygen saturation (SpO2), heart rate (HR), and cerebral regional oxygen saturation (crSO2) with the use of a T-piece resuscitator (TPR) versus self-inflating bag (SIB) as a mode of providing positive pressure ventilation (PPV) during DR resuscitation in preterm neonates. Seventy-two preterm neonates were randomly allocated to receive PPV with TPR (n = 36) or SIB (n = 36). The primary outcome was SpO2 (%) at 5 min. The secondary outcomes included the time to achieve a SpO2 ≥ 80% and > 85%, HR > 100/min, fractional-inspired oxygen (FiO2) requirement, minute-specific SpO2, HR and FiO2 trends for the first 5 min of life, need for DR-intubation, crSO2, need and duration of respiratory support, and other in-hospital morbidities. Mean SpO2 at 5 min was 74.5 ± 17.8% and 69.4 ± 22.4%, in TPR and SIB groups, respectively [Mean difference, 95% Confidence Interval 5.08 (-4.41, 14.58); p = 0.289]. No difference was observed in the time to achieve a SpO2 ≥ 80% and > 85%, HR > 100/min, the requirement of FiO2, DR-intubation, and the need and duration of respiratory support. There was no significant difference in the minute-specific SpO2, HR, and FiO2 requirements for the first 5 min. CrSO2 (%) at one hour was lower by 5% in the TPR group compared to SIB; p = 0.03. Other complications were comparable. CONCLUSIONS TPR and SIB resulted in comparable SpO2 at 5 min along with similar minute-specific SpO2, HR, and FiO2 trends. CLINICAL TRIAL REGISTRATION Clinical trial registry of India, Registration no: CTRI/2021/10/037384, Registered prospectively on: 20/10/2021, https://ctri.icmr.org.in/ . WHAT IS KNOWN • Compared to self-inflating bags (SIB), T-piece resuscitators (TPR) provide more consistent inflation pressure and tidal volume as shown in animal and bench studies. • There is no strong recommendation for one device over the other in view of low certainty evidence. WHAT IS NEW • TPR and SIB resulted in comparable peripheral oxygen saturation (SpO2) at 5 min along with similar minute-specific SpO2, heart rate, and fractional-inspired oxygen requirement trends. • Short-term complications and mortality rates were comparable with both devices.
Collapse
Affiliation(s)
- Bhrajishna Pallapothu
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Mayank Priyadarshi
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Poonam Singh
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Sourabh Kumar
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Suman Chaurasia
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Sriparna Basu
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India.
| |
Collapse
|
2
|
Gunawardana S, Arattu Thodika FMS, Murthy V, Bhat P, Williams EE, Dassios T, Milner AD, Greenough A. Respiratory function monitoring during early resuscitation and prediction of outcomes in prematurely born infants. J Perinat Med 2023; 51:950-955. [PMID: 36800988 DOI: 10.1515/jpm-2022-0538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 01/25/2023] [Indexed: 02/21/2023]
Abstract
OBJECTIVES Over the last decade, there has been increased use of end-tidal carbon dioxide (ETCO2) and oxygen saturation (SpO2) monitoring during resuscitation of prematurely born infants in the delivery suite. Our objectives were to test the hypotheses that low end-tidal carbon dioxide (ETCO2) levels, low oxygen saturations (SpO2) and high expiratory tidal volumes (VTE) during the early stages of resuscitation would be associated with adverse outcomes in preterm infants. METHODS Respiratory recordings made in the first 10 min of resuscitation in the delivery suite of 60 infants, median GA 27 (interquartile range 25-29) weeks were analysed. The results were compared of infants who did or did not die or did or did not develop intracerebral haemorrhage (ICH) or bronchopulmonary dysplasia (BPD). RESULTS Twenty-five infants (42%) developed an ICH and 23 (47%) BPD; 11 (18%) died. ETCO2 at approximately 5 min after birth was lower in infants who developed an ICH, this remained significant after adjusting for gestational age, coagulopathy and chorioamnionitis (p=0.03). ETCO2 levels were lower in infants who developed ICH or died compared to those that survived without ICH, which remained significant after adjustment for gestational age, Apgar score at 10 min, chorioamnionitis and coagulopathy (p=0.004). SpO2 at approximately 5 min was lower in the infants who died compared to those who survived which remained significant after adjusting for the 5-min Apgar score and chorioamnionitis (p=0.021). CONCLUSIONS ETCO2 and SpO2 levels during early resuscitation in the delivery suite were associated with adverse outcomes.
Collapse
Affiliation(s)
- Shannon Gunawardana
- Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Fahad M S Arattu Thodika
- Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Vadivelam Murthy
- Neonatal Intensive Care Centre, Barts Health NHS Trust, London, UK
| | - Prashanth Bhat
- Neonatal Intensive Care Centre, Brighton and Sussex University Hospital, Sussex, UK
| | - Emma E Williams
- Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Theodore Dassios
- Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
- Neonatal Intensive Care Centre, King's College Hospital NHS Foundation Trust, London, UK
| | - Anthony D Milner
- Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Anne Greenough
- Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, London, UK
| |
Collapse
|
3
|
Edwards H, Dorner RA, Katheria AC. Optimizing transition: Providing oxygen during intact cord resuscitation. Semin Perinatol 2023; 47:151787. [PMID: 37380527 PMCID: PMC10529853 DOI: 10.1016/j.semperi.2023.151787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/30/2023]
Abstract
Delayed clamping and cutting of the umbilical cord at birth is standard practice for management for all newborns. Preterm infants may additionally benefit from a combination of ventilation and oxygen provision during intact cord resuscitation. This review highlights both the potential benefits of such a combined approach and the need for further rigorous studies, including randomized controlled trials, of delivery room management in this population.
Collapse
Affiliation(s)
- Hannah Edwards
- Neonatal Research Institute, Sharp Mary Birch Hospital for Women & Newborns, San Diego, CA, United States
| | - Rebecca A Dorner
- Neonatal Research Institute, Sharp Mary Birch Hospital for Women & Newborns, San Diego, CA, United States
| | - Anup C Katheria
- Neonatal Research Institute, Sharp Mary Birch Hospital for Women & Newborns, San Diego, CA, United States.
| |
Collapse
|
4
|
Sotiropoulos JX, Vento M, Saugstad OD, Oei JL. The quest for optimum oxygenation during newborn delivery room resuscitation: Is it the baby or is it us? Semin Perinatol 2022; 46:151622. [PMID: 35725654 DOI: 10.1016/j.semperi.2022.151622] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Achieving "normal oxygenation" in sick newborn infants requiring resuscitation is one of the most difficult and incompletely informed practices in neonatal care. Suboptimal oxygenation, whether too little or too much, has profound repercussions, including death. In the last two decades, clinicians have lost equipoise for the use of higher oxygen strategies due to concerns of hyperoxia but emerging evidence suggests that lower oxygen strategies may also be as detrimental, especially in infants with pulmonary pathologies such as those born at the cusp of viability. Practice at the coalface using rapidly evolving recommendations has also uncovered continuing complexities in the quest to achieve optimum oxygenation during the first critical minutes of life. There are adjustable factors, such as the practical impediments to acquiring knowledge, equipment and expertise as well as unadjustable factors, such as inherent infant pathology, that necessitates agile clinical manipulation to "first do no harm". This review will address the deficiencies in knowledge that currently impede our quest to determine the best and safest means to deliver oxygen to sick infants during the first critical minutes of life and suggest practical solutions for current practice while awaiting definitive evidence from large scale, well defined, randomized controlled studies.
Collapse
Affiliation(s)
- James Xavier Sotiropoulos
- Faculty of Medicine, School of Women's and Children's Health, University of New South Wales, Kensington, NSW, Australia; Department of Newborn Care, The Royal Hospital for Women, Randwick, NSW, Australia
| | - Maximo Vento
- University and Polytechnic Hospital La Fe, Valencia, Spain; Health Research Institute La Fe, Valencia, Spain
| | - Ola D Saugstad
- Northwestern University, Chicago, USA; University of Oslo, Oslo, Norway
| | - Ju Lee Oei
- Faculty of Medicine, School of Women's and Children's Health, University of New South Wales, Kensington, NSW, Australia; Department of Newborn Care, The Royal Hospital for Women, Randwick, NSW, Australia.
| |
Collapse
|
5
|
Sotiropoulos JX, Kapadia V, Vento M, Rabi Y, Saugstad OD, Kumar RK, Schmölzer GM, Zhang H, Yuan Y, Lim G, Kusuda S, Arimitsu T, Nguyen TT, Kitsommart R, Yeo KT, Oei JL. Oxygen for the delivery room respiratory support of moderate-to-late preterm infants. An international survey of clinical practice from 21 countries. Acta Paediatr 2021; 110:3261-3268. [PMID: 34473855 DOI: 10.1111/apa.16091] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 08/20/2021] [Accepted: 08/31/2021] [Indexed: 12/11/2022]
Abstract
AIM The aim of this study was to determine clinician opinion regarding oxygen management in moderate-late preterm resuscitation. METHODS An anonymous online questionnaire was distributed through email/social messaging platforms to neonatologists in 21 countries (October 2020-March 2021) via REDCap. RESULTS Of the 695 respondents, 69% had access to oxygen blenders and 90% had pulse oximeters. Respondents from high-income countries were more likely to have oxygen blenders than those from middle-income countries (72% vs. 66%). Most initiated respiratory support with FiO2 0.21 (43%) or 0.3 (36%) but only 45% titrated FiO2 to target SpO2 . Most (89%) considered heart rate as a more important indicator of response than SpO2 . Almost all (96%) supported the need for well-designed trials to examine oxygenation in moderate-late preterm resuscitation. CONCLUSION Most clinicians resuscitated moderate-late preterm infants with lower initial FiO2 but some cannot/will not target SpO2 or titrate FiO2 . Most consider heart rate as a more important indicator of infant response than SpO2 .Large and robust clinical trials examining oxygen use for moderate-late preterm resuscitation, including long-term neurodevelopmental outcomes, are supported amongst clinicians.
Collapse
Affiliation(s)
- James X. Sotiropoulos
- Faculty of Medicine School of Women’s and Children’s Health University of New South Wales Sydney NSW Australia
- Department of Newborn Care The Royal Hospital for Women Randwick NSW Australia
| | - Vishal Kapadia
- Department of Pediatrics U.T. Southwestern Medical Center Dallas TX USA
| | - Maximo Vento
- Health Research Institute La Fe Valencia Spain
- University and Polytechnic Hospital La Fe Valencia Spain
| | - Yacov Rabi
- Department of Pediatrics Alberta Children's Hospital Research Institute University of Calgary Calgary AB Canada
| | - Ola D. Saugstad
- Northwestern University Chicago USA
- University of Oslo Oslo Norway
| | | | - Georg M. Schmölzer
- Centre for the Studies of Asphyxia and Resuscitation Neonatal Research Unit Royal Alexandra Hospital Edmonton AB Canada
- Department of Pediatrics University of Alberta Edmonton AB Canada
| | - Huyan Zhang
- Division of Neonatology Department of Pediatrics Children's Hospital of Philadelphia Philadelphia and University of Pennsylvania Perelman School of Medicine Philadelphia PA USA
- Guangzhou Women and Children’s Medical Center Tianhe District Guangzhou China
| | - Yuan Yuan
- Guangzhou Women and Children’s Medical Center Tianhe District Guangzhou China
| | - Gina Lim
- Department of Pediatrics Ulsan University Hospital Ulsan South Korea
| | - Satoshi Kusuda
- Department of Pediatrics Faculty of Medicine Kyorin University Tokyo Japan
| | - Takeshi Arimitsu
- Department of Pediatrics Keio University School of Medicine Tokyo Japan
| | - Tinh Thu Nguyen
- Department of Pediatrics University of Medicine and Pharmacy at Ho Chi Minh City Ho Chi Minh City Vietnam
| | - Ratchada Kitsommart
- Division of Neonatology Department of Pediatrics Faculty of Medicine Siriraj Hospital Mahidol University Bangkok Thailand
| | - Kee Thai Yeo
- Department of Neonatology KK Women’s and Children’s Hospital Singapore Singapore
| | - Ju Lee Oei
- Faculty of Medicine School of Women’s and Children’s Health University of New South Wales Sydney NSW Australia
- Department of Newborn Care The Royal Hospital for Women Randwick NSW Australia
| |
Collapse
|
6
|
Higher versus Lower Oxygen Concentration during Respiratory Support in the Delivery Room in Extremely Preterm Infants: A Pilot Feasibility Study. CHILDREN 2021; 8:children8110942. [PMID: 34828655 PMCID: PMC8625238 DOI: 10.3390/children8110942] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 10/07/2021] [Accepted: 10/15/2021] [Indexed: 11/28/2022]
Abstract
Background: Optimal starting oxygen concentration for delivery room resuscitation of extremely preterm infants (<29 weeks) remains unknown, with recommendations of 21–30% based on uncertain evidence. Individual patient randomized trials designed to answer this question have been hampered by poor enrolment. Hypothesis: It is feasible to compare 30% vs. 60% starting oxygen for delivery room resuscitation of extremely preterm infants using a change in local hospital policy and deferred consent approach. Study design: Prospective, single-center, feasibility study, with each starting oxygen concentration used for two months for all eligible infants. Population: Infants born at 23 + 0–28 + 6 weeks’ gestation who received delivery room resuscitation. Study interventions: Initial oxygen at 30% or 60%, increasing by 10–20% every minute for heart rate < 100 bpm, or increase to 100% for chest compressions. Primary outcome: Feasibility, defined by (i) achieving difference in cumulative supplied oxygen concentration between groups, and (ii) post-intervention rate consent >50%. Results: Thirty-four infants were born during a 4-month period; consent was obtained in 63%. Thirty (n = 12, 30% group; n = 18, 60% group) were analyzed, including limited data from eight who died or were transferred before parents could be approached. Median cumulative oxygen concentrations were significantly different between the two groups in the first 5 min. Conclusion: Randomized control trial of 30% or 60% oxygen at the initiation of resuscitation of extremely preterm neonates with deferred consent is feasible. Trial registration: Clinicaltrials.gov NCT03706586
Collapse
|
7
|
Delivery room oxygen physiology and respiratory interventions for newborns with cyanotic congenital heart disease. J Perinatol 2021; 41:2309-2316. [PMID: 33758390 DOI: 10.1038/s41372-021-01029-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 02/07/2021] [Accepted: 02/19/2021] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To characterize pulse oxygen saturation (SpO2) trajectories and respiratory interventions after birth for newborns with cyanotic congenital heart disease (CCHD). STUDY DESIGN Retrospective single-site study of newborns ≥32 weeks gestation with CCHD: single ventricle with critical aortic obstruction (SV-CAO), critical pulmonic obstruction (CPO), transposition of the great arteries (TGA). Minute-to-minute SpO2 values and respiratory interventions were summarized and compared. RESULTS Two hundred infants were enrolled. SpO2 at each minute differed across groups (p < 0.01), with the lowest values in TGA. All interventions were most frequent in TGA (p < 0.01). Continuous positive airway pressure was provided in 22% SV-CAO, 23% CPO, and 66% TGA. Positive pressure ventilation occurred in 7% SV-CAO, 14% CPO, and 33% TGA. Intubation occurred in 4% SV-CAO, 10% CPO, and 53% TGA. CONCLUSION We defined SpO2 trajectories and delivery room respiratory interventions for three CCHD phenotypes. These results inform delivery room management of these high-risk populations.
Collapse
|
8
|
Lakshminrusimha S, Vali P, Chandrasekharan P, Rich W, Katheria A. Differential Alveolar and Systemic Oxygenation during Preterm Resuscitation with 100% Oxygen during Delayed Cord Clamping. Am J Perinatol 2021; 40:630-637. [PMID: 34062568 DOI: 10.1055/s-0041-1730362] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Delayed cord clamping (DCC) and 21 to 30% O2 resuscitation is recommended for preterm infants but is commonly associated with low pulmonary blood flow (Qp) and hypoxia. 100% O2 supplementation during DCC for 60 seconds followed by 30% O2 may increase Qp and oxygen saturation (SpO2). STUDY DESIGN Preterm lambs (125-127 days of gestation) were resuscitated with 100% O2 with immediate cord clamping (ICC, n = 7) or ICC + 30% O2, and titrated to target SpO2 (n = 7) or DCC + 100% O2 for 60 seconds, which followed by cord clamping and 30% O2 titration (n = 7). Seven preterm (23-27 weeks of gestation) human infants received continuous positive airway pressure (CPAP) + 100% O2 for 60 seconds during DCC, cord clamping, and 30% O2 supplementation after cord clamping. RESULTS Preterm lambs in the ICC + 100% O2 group resulted in PaO2 (77 ± 25 mmHg), SpO2 (77 ± 11%), and Qp (27 ± 9 mL/kg/min) at 60 seconds. ICC + 30% O2 led to low Qp (14 ± 3 mL/kg/min), low SpO2 (43 ± 26%), and PaO2 (19 ± 7 mmHg). DCC + 100% O2 led to similar Qp (28 ± 6 mL/kg/min) as ICC + 100% O2 with lower PaO2. In human infants, DCC + CPAP with 100% O2 for 60 seconds, which followed by weaning to 30% resulted in SpO2 of 92 ± 11% with all infants >80% at 5 minutes with 100% survival without severe intraventricular hemorrhage. CONCLUSION DCC + 100% O2 for 60 seconds increased Qp probably due to transient alveolar hyperoxia with systemic normoxia due to "dilution" by umbilical venous return. Larger translational and clinical studies are warranted to confirm these findings. KEY POINTS · Transient alveolar hyperoxia during delayed cord clamping can enhance pulmonary vasodilation.. · Placental transfusion buffers systemic oxygen tension and limits hyperoxia.. · Use of 100% oxygen for 60 seconds during DCC was associated with SpO2 ≥80% by 5 minutes..
Collapse
Affiliation(s)
| | - Payam Vali
- Department of Pediatrics, University of California Davis, Sacramento, California
| | | | - Wade Rich
- Neonatal Research Institute, Sharp Mary Birch Hospital for Women and Newborns, San Diego, California
| | - Anup Katheria
- Neonatal Research Institute, Sharp Mary Birch Hospital for Women and Newborns, San Diego, California
| |
Collapse
|