1
|
Rasekh M, Harrison S, Schobesberger S, Ertl P, Balachandran W. Reagent storage and delivery on integrated microfluidic chips for point-of-care diagnostics. Biomed Microdevices 2024; 26:28. [PMID: 38825594 DOI: 10.1007/s10544-024-00709-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/02/2024] [Indexed: 06/04/2024]
Abstract
Microfluidic-based point-of-care diagnostics offer several unique advantages over existing bioanalytical solutions, such as automation, miniaturisation, and integration of sensors to rapidly detect on-site specific biomarkers. It is important to highlight that a microfluidic POC system needs to perform a number of steps, including sample preparation, nucleic acid extraction, amplification, and detection. Each of these stages involves mixing and elution to go from sample to result. To address these complex sample preparation procedures, a vast number of different approaches have been developed to solve the problem of reagent storage and delivery. However, to date, no universal method has been proposed that can be applied as a working solution for all cases. Herein, both current self-contained (stored within the chip) and off-chip (stored in a separate device and brought together at the point of use) are reviewed, and their merits and limitations are discussed. This review focuses on reagent storage devices that could be integrated with microfluidic devices, discussing further issues or merits of these storage solutions in two different sections: direct on-chip storage and external storage with their application devices. Furthermore, the different microvalves and micropumps are considered to provide guidelines for designing appropriate integrated microfluidic point-of-care devices.
Collapse
Affiliation(s)
- Manoochehr Rasekh
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.
| | - Sam Harrison
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK
| | - Silvia Schobesberger
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9, 1060, Vienna, Austria
| | - Peter Ertl
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9, 1060, Vienna, Austria
| | - Wamadeva Balachandran
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.
| |
Collapse
|
2
|
Qian C, Wan C, Li S, Xiao Y, Yuan H, Gao S, Wu L, Zhou M, Feng X, Li Y, Chen P, Liu BF. On-Line Dual-Active Valves Based Centrifugal Microfluidic Chip for Fully Automated Point-of-Care Immunoassay. Anal Chem 2023; 95:12521-12531. [PMID: 37556853 DOI: 10.1021/acs.analchem.3c02564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2023]
Abstract
There remains an unmet need for a fully integrated microfluidic platform that can automatically perform multistep and multireagent immunoassays. Here, we proposed a novel online dual-active valve-based centrifugal microfluidic chip, termed DAVM, for fully automatic point-of-care immunoassay. Practically, the puncture valve, one of the dual active valves, is capable of achieving precise, on-demand, sequential release of prestored reagents, while the other valve-reversible active valve enables controlled retention and drainage of the reaction solutions. Thereby, our technology mitigates the challenges of hydrophilic/hydrophobic modifications and unstable valve control performance commonly observed in passive valve controls. As a proof of concept, the indirect enzymatic immunoblotting technique was employed on DAVM for fully automated immunological analysis of eight targets, yielding outcomes within an hour. Furthermore, we conducted a comparative analysis of 28 clinical samples with autoimmune diseases. According to 224 clinical data, the sample testing concordance rate between DAVM and the traditional instrument was 82%, with a target compliance rate of 97%. Therefore, our DAVM system has powerful potential for fully automated immunoassays.
Collapse
Affiliation(s)
- Chungen Qian
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Chao Wan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Shunji Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yujin Xiao
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Huijuan Yuan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Siyu Gao
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Liqiang Wu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Mengfan Zhou
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xiaojun Feng
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
3
|
Zhou S, Jiang L, Dong Z. Overflow Control for Sustainable Development by Superwetting Surface with Biomimetic Structure. Chem Rev 2023; 123:2276-2310. [PMID: 35522923 DOI: 10.1021/acs.chemrev.1c00976] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Liquid flowing around a solid edge, i.e., overflow, is a commonly observed flow behavior. Recent research into surface wetting properties and microstructure-controlled overflow behavior has attracted much attention. Achieving controllable macroscale liquid dynamics by manipulating the micro-nanoscale liquid overflow has stimulated diverse scientific interest and fostered widespread use in practical applications. In this review, we outline the evolution of overflow and present a critical survey of the mechanism of surface wetting properties and microstructure-controlled liquid overflow in multilength scales ranging from centimeter to micro and even nanoscale. We summarize the latest progress in utilizing the mechanisms to manipulate liquid overflow and achieve macroscale liquid dynamics and in emerging applications to manipulate overflow for sustainable development in various fields, along with challenges and perspectives.
Collapse
Affiliation(s)
- Shan Zhou
- CAS Key Laboratory of Bio-inspired Materials and Interfacial Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, P. R. China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Lei Jiang
- CAS Key Laboratory of Bio-inspired Materials and Interfacial Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, P. R. China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Zhichao Dong
- CAS Key Laboratory of Bio-inspired Materials and Interfacial Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, P. R. China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| |
Collapse
|
4
|
Peshin S, Madou M, Kulinsky L. Microvalves for Applications in Centrifugal Microfluidics. SENSORS (BASEL, SWITZERLAND) 2022; 22:8955. [PMID: 36433550 PMCID: PMC9693484 DOI: 10.3390/s22228955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/11/2022] [Accepted: 11/17/2022] [Indexed: 06/16/2023]
Abstract
Centrifugal microfluidic platforms (CDs) have opened new possibilities for inexpensive point-of-care (POC) diagnostics. They are now widely used in applications requiring polymerase chain reaction steps, blood plasma separation, serial dilutions, and many other diagnostic processes. CD microfluidic devices allow a variety of complex processes to transfer onto the small disc platform that previously were carried out by individual expensive laboratory equipment requiring trained personnel. The portability, ease of operation, integration, and robustness of the CD fluidic platforms requires simple, reliable, and scalable designs to control the flow of fluids. Valves play a vital role in opening/closing of microfluidic channels to enable a precise control of the flow of fluids on a centrifugal platform. Valving systems are also critical in isolating chambers from the rest of a fluidic network at required times, in effectively directing the reagents to the target location, in serial dilutions, and in integration of multiple other processes on a single CD. In this paper, we review the various available fluidic valving systems, discuss their working principles, and evaluate their compatibility with CD fluidic platforms. We categorize the presented valving systems into either "active", "passive", or "hybrid"-based on their actuation mechanism that can be mechanical, thermal, hydrophobic/hydrophilic, solubility-based, phase-change, and others. Important topics such as their actuation mechanism, governing physics, variability of performance, necessary disc spin rate for valve actuation, valve response time, and other parameters are discussed. The applicability of some types of valves for specialized functions such as reagent storage, flow control, and other applications is summarized.
Collapse
Affiliation(s)
- Snehan Peshin
- Department of Mechanical and Aerospace Engineering, University of California, Irvine, CA 92697, USA
| | - Marc Madou
- Department of Mechanical and Aerospace Engineering, University of California, Irvine, CA 92697, USA
- School of Engineering and Science, Tecnológico de Monterrey, Monterrey 64849, Mexico
| | - Lawrence Kulinsky
- Department of Mechanical and Aerospace Engineering, University of California, Irvine, CA 92697, USA
| |
Collapse
|
5
|
Liang C, Yang Z, Jiang H. A film-lever actuated switch technology for multifunctional, on-demand, and robust manipulation of liquids. Nat Commun 2022; 13:4902. [PMID: 35987906 PMCID: PMC9391643 DOI: 10.1038/s41467-022-32676-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 08/11/2022] [Indexed: 11/15/2022] Open
Abstract
A lab-on-a-chip system with Point-of-Care testing capability offers rapid and accurate diagnostic potential and is useful in resource-limited settings where biomedical equipment and skilled professionals are not readily available. However, a Point-of-Care testing system that simultaneously possesses all required features of multifunctional dispensing, on-demand release, robust operations, and capability for long-term reagent storage is still a major challenge. Here, we describe a film-lever actuated switch technology that can manipulate liquids in any direction, provide accurate and proportional release response to the applied pneumatic pressure, as well as sustain robustness during abrupt movements and vibrations. Based on the technology, we also describe development of a polymerase chain reaction system that integrates reagent introduction, mixing and reaction functions all in one process, which accomplishes “sample-in-answer-out” performance for all clinical nasal samples from 18 patients with Influenza and 18 individual controls, in good concordance of fluorescence intensity with standard polymerase chain reaction (Pearson coefficients > 0.9). The proposed platform promises robust automation of biomedical analysis, and thus can accelerate the commercialization of a range of Point-of-Care testing devices. Point-of-care testing offers rapid and accurate diagnostic potential being quite useful in resource-limited settings. Here, authors demonstrate a film-lever actuated switch technology for microfluidic manipulation enabling multifunctional dispensing, on-demand release, robust operation, and long-term storage.
Collapse
|
6
|
Uddin R, Kinahan D, Ducrée J, Boisen A. Lab-on-a-disk extraction of PBMC and metered plasma from whole blood: An advanced event-triggered valving strategy. BIOMICROFLUIDICS 2021; 15:064102. [PMID: 34804316 PMCID: PMC8580574 DOI: 10.1063/5.0066128] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Accepted: 10/10/2021] [Indexed: 06/13/2023]
Abstract
In this paper, we present a centrifugal microfluidic concept employing event-triggered valving for automated extraction of metered plasma and peripheral blood mononuclear cells (PBMCs). This "lab-on-a-disk" system has been developed for retrieving different density layers from a liquid column by "overflowing" the layers sequentially using the pressure exerted by a density-gradient liquid. Defined volumes of plasma and PBMCs were efficiently forwarded into designated microfluidic chambers as a sample preparation step prior to further downstream processing. Furthermore, the extracted PBMCs were counted directly on-disk using an automated optical unit by object-based image analysis, thus eliminating the requirement for the post-processing of the extracted PBMCs. This study is a direct continuation of our previous work1 where we demonstrated combined on-disk detection of C-reactive protein and quantification of PBMCs following on-disk extraction of plasma and PBMCs from a single blood sample using a centrifugo-pneumatic valving mechanism. However, the former valving technique featured limited PBMC extraction efficiency. Here, integrating the novel concept along with event-triggered valving mechanism, we eliminated the occurrence of a specific microfluidic effect, which led us to increase PBMC extraction efficiency to 88%. This extraction method has the potential to be utilized for efficiently separating multiple density layers from a liquid sample in relevant biomedical applications.
Collapse
Affiliation(s)
- Rokon Uddin
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
| | - David Kinahan
- Department of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Jens Ducrée
- FPC@DCU—Fraunhofer Project Center at Dublin City University, Glasnevin, Dublin 9, Ireland
| | | |
Collapse
|
7
|
Maximiano EM, Gonçalves DA, Martins CA, Angnes L, Gomes RS, Trindade MAG. Simultaneous separation and electroanalysis in a single polydimethylsiloxane-based platform. Talanta 2021; 233:122514. [PMID: 34215129 DOI: 10.1016/j.talanta.2021.122514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/04/2021] [Accepted: 05/08/2021] [Indexed: 11/15/2022]
Abstract
Channel-based microfluidic devices integrating the separation step and detection system are key factors to expand microanalysis application. However, these devices still depend on macroscale external equipment for pre-treatment of the sample, separation, or detection. The integration of all steps in only one stage is critical to improving feasibility. Herein, we use a low-cost protocol to solve part of the challenge by designing a dual-mode system onto single polydimethylsiloxane (PDMS)-based platform - overall dimensions of 65 mm length × 20 mm width × 14 mm height and the inner diameter of 297±10 μm height × 605±19 μm width - for column-free separation and simultaneous detection. As a proof-of-concept, we used this all-in-one PDMS platform to separate - without the packet-based phase - and determine salicylic acid (SA) and caffeine (CAF) with a detection limit of 0.20 and 0.18 μmol L-1 and quantification limit of 0.70 and 0.60 μmol L-1 for SA and CAF, respectively. We separated the mixture using forced convection into a chemically treated microchannel while detecting the analytes in amperometric mode. Here, we report new insights into how integrating analytes separation and further electroanalysis into a single miniaturized device.
Collapse
Affiliation(s)
- Elizabete M Maximiano
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil
| | - Daniel A Gonçalves
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil
| | - Cauê A Martins
- Institute of Physics, Universidade Federal de Mato Grosso do Sul, CEP 79070-900, Campo Grande, MS, Brazil
| | - Lucio Angnes
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000, São Paulo, SP, Brazil
| | - Roberto S Gomes
- Department of Pharmaceutical Sciences, North Dakota State University, Fargo, ND, USA
| | - Magno A G Trindade
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil; Unesp, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, CEP 14800-900, Araraquara, SP, Brazil.
| |
Collapse
|
8
|
Abstract
Lab-on-a-Disc (LoaD) biosensors are increasingly a promising solution for many biosensing applications. In the search for a perfect match between point-of-care (PoC) microfluidic devices and biosensors, the LoaD platform has the potential to be reliable, sensitive, low-cost, and easy-to-use. The present global pandemic draws attention to the importance of rapid sample-to-answer PoC devices for minimising manual intervention and sample manipulation, thus increasing the safety of the health professional while minimising the chances of sample contamination. A biosensor is defined by its ability to measure an analyte by converting a biological binding event to tangible analytical data. With evolving manufacturing processes for both LoaDs and biosensors, it is becoming more feasible to embed biosensors within the platform and/or to pair the microfluidic cartridges with low-cost detection systems. This review considers the basics of the centrifugal microfluidics and describes recent developments in common biosensing methods and novel technologies for fluidic control and automation. Finally, an overview of current devices on the market is provided. This review will guide scientists who want to initiate research in LoaD PoC devices as well as providing valuable reference material to researchers active in the field.
Collapse
|
9
|
Hess JF, Kotrová M, Calabrese S, Darzentas N, Hutzenlaub T, Zengerle R, Brüggemann M, Paust N. Automation of Amplicon-Based Library Preparation for Next-Generation Sequencing by Centrifugal Microfluidics. Anal Chem 2020; 92:12833-12841. [DOI: 10.1021/acs.analchem.0c01202] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Jacob Friedrich Hess
- Laboratory for MEMS Applications, IMTEK-Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Michaela Kotrová
- Unit for Hematological Diagnostics, II. Medical Department, University Medical Center Schleswig Holstein, Langer Segen 8-10, 24105 Kiel, Germany
| | - Silvia Calabrese
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Nikos Darzentas
- Unit for Hematological Diagnostics, II. Medical Department, University Medical Center Schleswig Holstein, Langer Segen 8-10, 24105 Kiel, Germany
| | - Tobias Hutzenlaub
- Laboratory for MEMS Applications, IMTEK-Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Roland Zengerle
- Laboratory for MEMS Applications, IMTEK-Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Monika Brüggemann
- Unit for Hematological Diagnostics, II. Medical Department, University Medical Center Schleswig Holstein, Langer Segen 8-10, 24105 Kiel, Germany
| | - Nils Paust
- Laboratory for MEMS Applications, IMTEK-Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| |
Collapse
|
10
|
Madadelahi M, Acosta-Soto LF, Hosseini S, Martinez-Chapa SO, Madou MJ. Mathematical modeling and computational analysis of centrifugal microfluidic platforms: a review. LAB ON A CHIP 2020; 20:1318-1357. [PMID: 32242566 DOI: 10.1039/c9lc00775j] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Centrifugal microfluidic platforms or lab-on-discs (LODs) have evolved into a popular technology for automating chemical and biological assays. LODs today enable scientists to implement and integrate different operational units, including fluid mixing, droplet generation, cell-sorting, gene amplification, analyte detection, and so forth. For an efficient design and cost-effective implementation of any microfluidic device, including LODs, theoretical analysis and considerations should play a more important role than they currently do. The theoretical analysis we will show is especially essential to the investigation of detailed phenomena at the small length scales and high-speed typical for LODs where a wide range of forces may be involved. Previous LOD review papers presented mostly experimental results with theory as an afterthought. Hence, a review paper focused on the theoretical aspects, and associated computational studies of LOD devices is an urgent need. In the present review paper, all previous computational studies on LOD devices are categorized as single-phase flows, two-phase flows, network simulation, and solids. For each of these categories, the governing equations and important formulas are presented and explained. Moreover, a handy scaling analysis is introduced to aid scientists when comparing different competing forces in LOD devices. We hope that by surveying and contrasting various theoretical LOD studies, we shed some light on existing controversies and reveal where additional theoretical work is needed.
Collapse
Affiliation(s)
- Masoud Madadelahi
- School of Engineering and Sciences, Tecnologico de Monterrey, Ave. Eugenio Garza Sada 2501, Monterrey 64849, NL, Mexico.
| | | | | | | | | |
Collapse
|
11
|
Pishbin E, Kazemzadeh A, Chimerad M, Asiaei S, Navidbakhsh M, Russom A. Frequency dependent multiphase flows on centrifugal microfluidics. LAB ON A CHIP 2020; 20:514-524. [PMID: 31898702 DOI: 10.1039/c9lc00924h] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The simultaneous flow of gas and liquids in large scale conduits is an established approach to enhance the performance of different working systems under critical conditions. On the microscale, the use of gas-liquid flows is challenging due to the dominance of surface tension forces. Here, we present a technique to generate common gas-liquid flows on a centrifugal microfluidic platform. It consists of a spiral microchannel and specific micro features that allow for temporal and local control of stratified and slug flow regimes. We investigate several critical parameters that induce different gas-liquid flows and cause the transition between stratified and slug flows. We have analytically derived formulations that are compared with our experimental results to deliver a general guideline for designing specific gas-liquid flows. As an application of the gas-liquid flows in enhancing microfluidic systems' performance, we show the acceleration of the cell growth of E. coli bacteria in comparison to traditional culturing methods.
Collapse
Affiliation(s)
- Esmail Pishbin
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Amin Kazemzadeh
- Division of Nanobiotechnology, Department of Protein Sciences, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Mohammadreza Chimerad
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Sasan Asiaei
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Mahdi Navidbakhsh
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Aman Russom
- Division of Nanobiotechnology, Department of Protein Sciences, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden.
| |
Collapse
|
12
|
Agarwal R, Sarkar A, Paul S, Chakraborty S. A portable rotating disc as blood rheometer. BIOMICROFLUIDICS 2019; 13:064120. [PMID: 31803338 PMCID: PMC6887659 DOI: 10.1063/1.5128937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 11/19/2019] [Indexed: 06/10/2023]
Abstract
Abnormalities in biophysical properties of blood are often strong indicators of life threatening infections. However, there is no existing device that integrates the sensing of blood hematocrit (or equivalently, packed cell volume), viscosity, and erythrocyte sedimentation rate (ESR) in a unified paradigm for point-of-care diagnostics. In an effort to develop a rapid, integrated, accurate, portable, and inexpensive sensing platform to diagnose the corresponding pathophysical parameters, we develop a simple and portable spinning disk capable of yielding these results in a few minutes instead of the traditional duration of hours. The device requires only 40 μl of unprocessed freshly drawn blood treated with an anticoagulant ethylenediaminetetraacetic acid, instead of the traditional requirement of 2 ml of blood for just the ESR measurement and still more for hematocrit determination. In contrast to the sophisticated instrumentation required to determine these parameters by the previously proposed microfluidic devices, our device requires minimal infrastructure. The measurement of hematocrit is accomplished by means of a simple 15 cm ruler. Additionally, a simple measurement of the blood flow rate enables the determination of the ESR value. The rapidity, ease, accuracy, portability, frugality, and possible automation of the overall measurement process of some of the most important parameters of blood under infection pinpoint its utility in extreme point-of-care settings.
Collapse
Affiliation(s)
- Rahul Agarwal
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | | | - Subhechchha Paul
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur 711103, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
13
|
Torrinha Á, Montenegro MC, Araújo AN. Conjugation of glucose oxidase and bilirubin oxidase bioelectrodes as biofuel cell in a finger-powered microfluidic platform. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.06.140] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|