1
|
Nemirova S, Orlova A, Kurnikov A, Litvinova Y, Kazakov V, Ayvazyan I, Liu YH, Razansky D, Subochev P. Scanning optoacoustic angiography for assessing structural and functional alterations in superficial vasculature of patients with post-thrombotic syndrome: A pilot study. PHOTOACOUSTICS 2024; 38:100616. [PMID: 38770433 PMCID: PMC11103408 DOI: 10.1016/j.pacs.2024.100616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 04/21/2024] [Accepted: 05/05/2024] [Indexed: 05/22/2024]
Abstract
This study highlights the potential of scanning optoacoustic angiography (OA) in identifying alterations of superficial vasculature in patients with post-thrombotic syndrome (PTS) of the foot, a venous stress disorder associated with significant morbidity developing from long-term effects of deep venous thrombosis. The traditional angiography methods available in the clinics are not capable of reliably assessing the state of peripheral veins that provide blood outflow from the skin, a key hallmark of personalized risks of PTS formation after venous thrombosis. Our findings indicate that OA can detect an increase in blood volume, diameter, and tortuosity of superficial blood vessels. The inability to spatially separate vascular plexuses of the dermis and subcutaneous adipose tissue serves as a crucial criterion for distinguishing PTS from normal vasculature. Furthermore, our study demonstrates the ability of scanning optoacoustic angiography to detect blood filling decrease in an elevated limb position versus increase in a lowered position.
Collapse
Affiliation(s)
- Svetlana Nemirova
- Privolzhsky Research Medical University, 10/1 Minin & Pozharsky sq., Nizhny Novgorod 603950, Russia
- A.V. Gaponov-Grekhov Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| | - Anna Orlova
- A.V. Gaponov-Grekhov Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| | - Alexey Kurnikov
- A.V. Gaponov-Grekhov Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| | - Yulia Litvinova
- A.V. Gaponov-Grekhov Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| | - Viacheslav Kazakov
- A.V. Gaponov-Grekhov Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| | - Irina Ayvazyan
- A.V. Gaponov-Grekhov Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| | - Yu-Hang Liu
- Institute of Pharmacology and Toxicology and Institute for Biomedical Engineering and, Faculty of Medicine, University of Zurich, Winterthurerstrasse 190, Zurich 8057, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Wolfgang-Pauli-Strasse 27, Zurich 8093, Switzerland
| | - Daniel Razansky
- Institute of Pharmacology and Toxicology and Institute for Biomedical Engineering and, Faculty of Medicine, University of Zurich, Winterthurerstrasse 190, Zurich 8057, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Wolfgang-Pauli-Strasse 27, Zurich 8093, Switzerland
| | - Pavel Subochev
- A.V. Gaponov-Grekhov Institute of Applied Physics, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| |
Collapse
|
2
|
Kurnikov A, Sanin A, Ben XLD, Razansky D, Subochev P. Ultrawideband sub-pascal sensitivity piezopolymer detectors. ULTRASONICS 2024; 141:107349. [PMID: 38788335 DOI: 10.1016/j.ultras.2024.107349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 04/21/2024] [Accepted: 05/16/2024] [Indexed: 05/26/2024]
Abstract
Piezoelectric detectors are integral part of modern ultrasound imaging systems. Their utility has also been extended beyond the established methodologies into the emerging realm of hybrid optoacoustic imaging. Conventional piezoceramic detectors, however, struggle to combine high detection sensitivity with ultrawide bandwidth, both considered critical for attaining optimal optoacoustic imaging performance. Our research, both theoretical and empirical, unveils that damped piezopolymer detectors fabricated from PVDF-TrFE are markedly capable of achieving a synergistic blend between broad bandwidth and superb sensitivity. Experimental evaluations reflected an average sensitivity of 15.5 µV/Pa within a 1-10 MHz band for a 120 µm thick detector and 6.4 µV/Pa within a 1-30 MHz band for a 20 µm thick detector, thus outperforming conventional piezoelectric analogues. The resultant noise equivalent pressure (NEPs) values were 0.3 Pa and 1.2 Pa for the 20 µm and 120 µm detectors, respectively. Our findings herald a significant stride towards enhancing the efficacy of ultrawideband ultrasound and optoacoustic imaging systems.
Collapse
Affiliation(s)
- Alexey Kurnikov
- Institute of Applied Physics named after A.V. Gaponov-Grekhov, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia; University of Nizhny Novgorod, Department of Radiophysics, Gagarin Ave. 23, Nizhny Novgorod 603022, Russia
| | - Anatoly Sanin
- Institute of Applied Physics named after A.V. Gaponov-Grekhov, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| | - Xose Luis Dean Ben
- Institute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Winterthurerstrasse 190, CH-8057 Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Wolfgang-Pauli-Strasse 27, CH-8093 Zurich, Switzerland
| | - Daniel Razansky
- Institute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Winterthurerstrasse 190, CH-8057 Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Wolfgang-Pauli-Strasse 27, CH-8093 Zurich, Switzerland.
| | - Pavel Subochev
- Institute of Applied Physics named after A.V. Gaponov-Grekhov, Russian Academy of Sciences, 46 Ulyanov Str., Nizhny Novgorod 603950, Russia
| |
Collapse
|
3
|
He H, Paetzold JC, Borner N, Riedel E, Gerl S, Schneider S, Fisher C, Ezhov I, Shit S, Li H, Ruckert D, Aguirre J, Biedermann T, Darsow U, Menze B, Ntziachristos V. Machine Learning Analysis of Human Skin by Optoacoustic Mesoscopy for Automated Extraction of Psoriasis and Aging Biomarkers. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:2074-2085. [PMID: 38241120 DOI: 10.1109/tmi.2024.3356180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/21/2024]
Abstract
Ultra-wideband raster-scan optoacoustic mesoscopy (RSOM) is a novel modality that has demonstrated unprecedented ability to visualize epidermal and dermal structures in-vivo. However, an automatic and quantitative analysis of three-dimensional RSOM datasets remains unexplored. In this work we present our framework: Deep Learning RSOM Analysis Pipeline (DeepRAP), to analyze and quantify morphological skin features recorded by RSOM and extract imaging biomarkers for disease characterization. DeepRAP uses a multi-network segmentation strategy based on convolutional neural networks with transfer learning. This strategy enabled the automatic recognition of skin layers and subsequent segmentation of dermal microvasculature with an accuracy equivalent to human assessment. DeepRAP was validated against manual segmentation on 25 psoriasis patients under treatment and our biomarker extraction was shown to characterize disease severity and progression well with a strong correlation to physician evaluation and histology. In a unique validation experiment, we applied DeepRAP in a time series sequence of occlusion-induced hyperemia from 10 healthy volunteers. We observe how the biomarkers decrease and recover during the occlusion and release process, demonstrating accurate performance and reproducibility of DeepRAP. Furthermore, we analyzed a cohort of 75 volunteers and defined a relationship between aging and microvascular features in-vivo. More precisely, this study revealed that fine microvascular features in the dermal layer have the strongest correlation to age. The ability of our newly developed framework to enable the rapid study of human skin morphology and microvasculature in-vivo promises to replace biopsy studies, increasing the translational potential of RSOM.
Collapse
|
4
|
Guerra LO, Cortinoz JR, Vasques LI, Leonardi GR. Methods for skin image analysis and their applications in dermatology and cosmetic research: a comprehensive review. Ital J Dermatol Venerol 2024; 159:146-160. [PMID: 38376503 DOI: 10.23736/s2784-8671.23.07704-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024]
Abstract
INTRODUCTION In recent years, several non-invasive imaging methods have been introduced to facilitate studies in dermatology and cosmetic research, almost completely replacing invasive methods such as biopsy. Imaging devices have proven to be useful tools in skin analysis and therapy monitoring. This review aimed to investigate the most recent studies in cosmetic dermatology the imaging technology and methods that are being used to assess skin characteristics and summarize its fundamentals, possible applications, advantages, and limitations, and to give a future perspective to the clinical trials. EVIDENCE ACQUISITION For that, a literature review was carried out in the main scientific database platforms and the studies associating skin image analysis with dermatology and cosmetic research were selected and discussed. EVIDENCE SYNTHESIS It was possible to infer that skin image analyses are not only practical and effective, but have also become increasingly essential for the skin sciences. The in vivo and real-time image analyses allow a more complete evaluation and the follow-up of the same region for different periods. It was also possible to observe that macroscopic, microscopic, and mesoscopic imaging methods are complementary, allowing different approaches in the same study. CONCLUSIONS These technologies are expected to evolve more and more quickly in the near future.
Collapse
Affiliation(s)
- Lucas O Guerra
- Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
- ALS Life Sciences-Allergisa Pesquisa Dermato-Cosmética Ltda, São Paulo, Brazil
| | - Janaina R Cortinoz
- ALS Life Sciences-Allergisa Pesquisa Dermato-Cosmética Ltda, São Paulo, Brazil
| | - Louise I Vasques
- Faculty of Pharmaceutical Sciences, University of Campinas, Campinas, São Paulo, Brazil -
| | - Gislaine R Leonardi
- Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
- Faculty of Pharmaceutical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| |
Collapse
|
5
|
Mi J, Liu C, Chen H, Qian Y, Zhu J, Zhang Y, Liang Y, Wang L, Ta D. Light on Alzheimer's disease: from basic insights to preclinical studies. Front Aging Neurosci 2024; 16:1363458. [PMID: 38566826 PMCID: PMC10986738 DOI: 10.3389/fnagi.2024.1363458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Accepted: 03/04/2024] [Indexed: 04/04/2024] Open
Abstract
Alzheimer's disease (AD), referring to a gradual deterioration in cognitive function, including memory loss and impaired thinking skills, has emerged as a substantial worldwide challenge with profound social and economic implications. As the prevalence of AD continues to rise and the population ages, there is an imperative demand for innovative imaging techniques to help improve our understanding of these complex conditions. Photoacoustic (PA) imaging forms a hybrid imaging modality by integrating the high-contrast of optical imaging and deep-penetration of ultrasound imaging. PA imaging enables the visualization and characterization of tissue structures and multifunctional information at high resolution and, has demonstrated promising preliminary results in the study and diagnosis of AD. This review endeavors to offer a thorough overview of the current applications and potential of PA imaging on AD diagnosis and treatment. Firstly, the structural, functional, molecular parameter changes associated with AD-related brain imaging captured by PA imaging will be summarized, shaping the diagnostic standpoint of this review. Then, the therapeutic methods aimed at AD is discussed further. Lastly, the potential solutions and clinical applications to expand the extent of PA imaging into deeper AD scenarios is proposed. While certain aspects might not be fully covered, this mini-review provides valuable insights into AD diagnosis and treatment through the utilization of innovative tissue photothermal effects. We hope that it will spark further exploration in this field, fostering improved and earlier theranostics for AD.
Collapse
Affiliation(s)
- Jie Mi
- Yiwu Research Institute, Fudan University, Yiwu, China
| | - Chao Liu
- Yiwu Research Institute, Fudan University, Yiwu, China
- Digital Medical Research Center, School of Basic Medical Sciences, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention, Shanghai, China
| | - Honglei Chen
- Yiwu Research Institute, Fudan University, Yiwu, China
| | - Yan Qian
- Digital Medical Research Center, School of Basic Medical Sciences, Fudan University, Shanghai, China
- Shanghai Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention, Shanghai, China
| | - Jingyi Zhu
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China
| | - Yachao Zhang
- Medical Ultrasound Department, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Yizhi Liang
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Institute of Photonics Technology, Jinan University, Guangzhou, China
| | - Lidai Wang
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China
| | - Dean Ta
- Yiwu Research Institute, Fudan University, Yiwu, China
- Department of Electronic Engineering, Fudan University, Shanghai, China
| |
Collapse
|
6
|
Zou Z, Mao Q, Cheng R, Tao C, Liu X. Correction of high-rate motion for photoacoustic microscopy by orthogonal cross-correlation. Sci Rep 2024; 14:4264. [PMID: 38383553 PMCID: PMC10881994 DOI: 10.1038/s41598-024-53505-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 02/01/2024] [Indexed: 02/23/2024] Open
Abstract
Photoacoustic imaging is a promising technology for in vivo imaging. However, its imaging performance can be hampered by motion artifacts, especially when dealing with high-rate motion. In this paper, we propose an orthogonal motion correction method that utilizes cross-correlation along orthogonal scan directions to extract accurate motion displacements from the photoacoustic data. The extracted displacements are then applied to remove artifacts and compensate for motion-induced distortions. Phantom experiments demonstrate that the proposed method can extract the motion information and the structural similarity index measurement after correction is increased by 26.5% and 11.2% compared to no correction and the previous correction method. Then the effectiveness of our method is evaluated in vivo imaging of a mouse brain. Our method shows a stable and effective performance under high-rate motion. The high accuracy of the motion correction method makes it valuable in improving the accuracy of photoacoustic imaging.
Collapse
Affiliation(s)
- Zilong Zou
- MOE Key Laboratory of Modern Acoustics, Department of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing, 210093, China
| | - Qiuqin Mao
- MOE Key Laboratory of Modern Acoustics, Department of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing, 210093, China
| | - Renxiang Cheng
- School of Electronic and Information Engineering, Jinling Institute of Technology, Nanjing, 211169, China
| | - Chao Tao
- MOE Key Laboratory of Modern Acoustics, Department of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing, 210093, China.
| | - Xiaojun Liu
- MOE Key Laboratory of Modern Acoustics, Department of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing, 210093, China
| |
Collapse
|
7
|
He H, Fischer C, Darsow U, Aguirre J, Ntziachristos V. Quality control in clinical raster-scan optoacoustic mesoscopy. PHOTOACOUSTICS 2024; 35:100582. [PMID: 38312808 PMCID: PMC10835451 DOI: 10.1016/j.pacs.2023.100582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 12/15/2023] [Accepted: 12/21/2023] [Indexed: 02/06/2024]
Abstract
Optoacoustic (photoacoustic) mesoscopy bridges the gap between optoacoustic microscopy and macroscopy and enables high-resolution visualization deeper than optical microscopy. Nevertheless, as images may be affected by motion and noise, it is critical to develop methodologies that offer standardization and quality control to ensure that high-quality datasets are reproducibly obtained from patient scans. Such development is particularly important for ensuring reliability in applying machine learning methods or for reliably measuring disease biomarkers. We propose herein a quality control scheme to assess the quality of data collected. A reference scan of a suture phantom is performed to characterize the system noise level before each raster-scan optoacoustic mesoscopy (RSOM) measurement. Using the recorded RSOM data, we develop a method that estimates the amount of motion in the raw data. These motion metrics are employed to classify the quality of raw data collected and derive a quality assessment index (QASIN) for each raw measurement. Using simulations, we propose a selection criterion of images with sufficient QASIN, leading to the compilation of RSOM datasets with consistent quality. Using 160 RSOM measurements from healthy volunteers, we show that RSOM images that were selected using QASIN were of higher quality and fidelity compared to non-selected images. We discuss how this quality control scheme can enable the standardization of RSOM images for clinical and biomedical applications.
Collapse
Affiliation(s)
- Hailong He
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Chiara Fischer
- Department of Dermatology and Allergy, Technical University of Munich, Munich, Germany
| | - Ulf Darsow
- Department of Dermatology and Allergy, Technical University of Munich, Munich, Germany
| | - Juan Aguirre
- Departamento de Tecnología Electrónica y de las Comunicaciones, Universidad Autónoma de Madrid, Madrid, Spain
- Instituto de Investigación Sanitaria de la Fundación Jimenez Diaz, Madrid, Spain
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| |
Collapse
|
8
|
Eleni Karakatsani M, Estrada H, Chen Z, Shoham S, Deán-Ben XL, Razansky D. Shedding light on ultrasound in action: Optical and optoacoustic monitoring of ultrasound brain interventions. Adv Drug Deliv Rev 2024; 205:115177. [PMID: 38184194 DOI: 10.1016/j.addr.2023.115177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 12/27/2023] [Accepted: 12/31/2023] [Indexed: 01/08/2024]
Abstract
Monitoring brain responses to ultrasonic interventions is becoming an important pillar of a growing number of applications employing acoustic waves to actuate and cure the brain. Optical interrogation of living tissues provides a unique means for retrieving functional and molecular information related to brain activity and disease-specific biomarkers. The hybrid optoacoustic imaging methods have further enabled deep-tissue imaging with optical contrast at high spatial and temporal resolution. The marriage between light and sound thus brings together the highly complementary advantages of both modalities toward high precision interrogation, stimulation, and therapy of the brain with strong impact in the fields of ultrasound neuromodulation, gene and drug delivery, or noninvasive treatments of neurological and neurodegenerative disorders. In this review, we elaborate on current advances in optical and optoacoustic monitoring of ultrasound interventions. We describe the main principles and mechanisms underlying each method before diving into the corresponding biomedical applications. We identify areas of improvement as well as promising approaches with clinical translation potential.
Collapse
Affiliation(s)
- Maria Eleni Karakatsani
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Héctor Estrada
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Zhenyue Chen
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Shy Shoham
- Department of Ophthalmology and Tech4Health and Neuroscience Institutes, NYU Langone Health, NY, USA
| | - Xosé Luís Deán-Ben
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland.
| | - Daniel Razansky
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland.
| |
Collapse
|
9
|
Karlas A, Katsouli N, Fasoula NA, Bariotakis M, Chlis NK, Omar M, He H, Iakovakis D, Schäffer C, Kallmayer M, Füchtenbusch M, Ziegler A, Eckstein HH, Hadjileontiadis L, Ntziachristos V. Dermal features derived from optoacoustic tomograms via machine learning correlate microangiopathy phenotypes with diabetes stage. Nat Biomed Eng 2023; 7:1667-1682. [PMID: 38049470 PMCID: PMC10727986 DOI: 10.1038/s41551-023-01151-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 10/24/2023] [Indexed: 12/06/2023]
Abstract
Skin microangiopathy has been associated with diabetes. Here we show that skin-microangiopathy phenotypes in humans can be correlated with diabetes stage via morphophysiological cutaneous features extracted from raster-scan optoacoustic mesoscopy (RSOM) images of skin on the leg. We obtained 199 RSOM images from 115 participants (40 healthy and 75 with diabetes), and used machine learning to segment skin layers and microvasculature to identify clinically explainable features pertaining to different depths and scales of detail that provided the highest predictive power. Features in the dermal layer at the scale of detail of 0.1-1 mm (such as the number of junction-to-junction branches) were highly sensitive to diabetes stage. A 'microangiopathy score' compiling the 32 most-relevant features predicted the presence of diabetes with an area under the receiver operating characteristic curve of 0.84. The analysis of morphophysiological cutaneous features via RSOM may allow for the discovery of diabetes biomarkers in the skin and for the monitoring of diabetes status.
Collapse
Affiliation(s)
- Angelos Karlas
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
- Department for Vascular and Endovascular Surgery, Klinikum rechts der Isar, Technical University of Munich (TUM), Munich, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany
| | - Nikoletta Katsouli
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Nikolina-Alexia Fasoula
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Michail Bariotakis
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Nikolaos-Kosmas Chlis
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
- Institute of Computational Biology, Helmholtz Zentrum München, Neuherberg, Germany
| | - Murad Omar
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Hailong He
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Dimitrios Iakovakis
- Department of Biomedical Engineering, Healthcare Engineering Innovation Center (HEIC), Khalifa University, Abu Dhabi, United Arab Emirates
- Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Christoph Schäffer
- Department for Vascular and Endovascular Surgery, Klinikum rechts der Isar, Technical University of Munich (TUM), Munich, Germany
| | - Michael Kallmayer
- Department for Vascular and Endovascular Surgery, Klinikum rechts der Isar, Technical University of Munich (TUM), Munich, Germany
| | | | - Annette Ziegler
- Forschergruppe Diabetes e.V., Helmholtz Zentrum München, Neuherberg, Germany
- Institute of Diabetes Research, Helmholtz Zentrum München, Neuherberg, Germany
- Forschergruppe Diabetes, Klinikum rechts der Isar, Technical University of Munich (TUM), Munich, Germany
| | - Hans-Henning Eckstein
- Department for Vascular and Endovascular Surgery, Klinikum rechts der Isar, Technical University of Munich (TUM), Munich, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany
| | - Leontios Hadjileontiadis
- Department of Biomedical Engineering, Healthcare Engineering Innovation Center (HEIC), Khalifa University, Abu Dhabi, United Arab Emirates
- Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany.
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany.
- DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany.
- Munich Institute of Robotics and Machine Intelligence (MIRMI), Technical University of Munich, Munich, Germany.
| |
Collapse
|
10
|
Yang F, Ding W, Fu X, Chen W, Tang J. Photoacoustic elasto-viscography and optical coherence microscopy for multi-parametric ex vivo brain imaging. BIOMEDICAL OPTICS EXPRESS 2023; 14:5615-5628. [PMID: 38021134 PMCID: PMC10659785 DOI: 10.1364/boe.503847] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 09/22/2023] [Accepted: 09/22/2023] [Indexed: 12/01/2023]
Abstract
Optical coherence microscopy (OCM) has shown the importance of imaging ex vivo brain slices at the microscopic level for a better understanding of the disease pathology and mechanism. However, the current OCM-based techniques are mainly limited to providing the tissue's optical properties, such as the attenuation coefficient, scattering coefficient, and cell architecture. Imaging the tissue's mechanical properties, including the elasticity and viscosity, in addition to the optical properties, to provide a comprehensive multi-parametric assessment of the sample has remained a challenge. Here, we present an integrated photoacoustic elasto-viscography (PAEV) and OCM imaging system to measure the sample's optical absorption coefficient, attenuation coefficient, and mechanical properties, including elasticity and viscosity. The obtained mechanical and optical properties were consistent with anatomical features observed in the PAEV and OCM images. The elasticity and viscosity maps showed rich variations of microstructural mechanical properties of mice brain. In the reconstructed elasto-viscogram of brain slices, greater elasticity, and lower viscosity were observed in white matter than in gray matter. With the ability to provide multi-parametric properties of the sample, the PAEV-OCM system holds the potential for a more comprehensive study of brain disease pathology.
Collapse
Affiliation(s)
- Fen Yang
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| | - Wenguo Ding
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| | - Xinlei Fu
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| | - Wei Chen
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| | - Jianbo Tang
- Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
| |
Collapse
|
11
|
Liu X, Jing Y, Xu C, Wang X, Xie X, Zhu Y, Dai L, Wang H, Wang L, Yu S. Medical Imaging Technology for Micro/Nanorobots. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2872. [PMID: 37947717 PMCID: PMC10648532 DOI: 10.3390/nano13212872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 10/23/2023] [Accepted: 10/26/2023] [Indexed: 11/12/2023]
Abstract
Due to their enormous potential to be navigated through complex biological media or narrow capillaries, microrobots have demonstrated their potential in a variety of biomedical applications, such as assisted fertilization, targeted drug delivery, tissue repair, and regeneration. Numerous initial studies have been conducted to demonstrate the biomedical applications in test tubes and in vitro environments. Microrobots can reach human areas that are difficult to reach by existing medical devices through precise navigation. Medical imaging technology is essential for locating and tracking this small treatment machine for evaluation. This article discusses the progress of imaging in tracking the imaging of micro and nano robots in vivo and analyzes the current status of imaging technology for microrobots. The working principle and imaging parameters (temporal resolution, spatial resolution, and penetration depth) of each imaging technology are discussed in depth.
Collapse
Affiliation(s)
- Xuejia Liu
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Yizhan Jing
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Chengxin Xu
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Xiaoxiao Wang
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Xiaopeng Xie
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Yanhe Zhu
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Lizhou Dai
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Haocheng Wang
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Lin Wang
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China; (X.L.); (Y.J.); (C.X.); (X.W.); (X.X.); (Y.Z.); (L.D.); (L.W.)
| | - Shimin Yu
- College of Engineering, Ocean University of China, Qingdao 266100, China
| |
Collapse
|
12
|
Zheng W, Zhang H, Huang C, Shijo V, Xu C, Xu W, Xia J. Deep Learning Enhanced Volumetric Photoacoustic Imaging of Vasculature in Human. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2301277. [PMID: 37530209 PMCID: PMC10582405 DOI: 10.1002/advs.202301277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 06/26/2023] [Indexed: 08/03/2023]
Abstract
The development of high-performance imaging processing algorithms is a core area of photoacoustic tomography. While various deep learning based image processing techniques have been developed in the area, their applications in 3D imaging are still limited due to challenges in computational cost and memory allocation. To address those limitations, this work implements a 3D fully-dense (3DFD) U-net to linear array based photoacoustic tomography and utilizes volumetric simulation and mixed precision training to increase efficiency and training size. Through numerical simulation, phantom imaging, and in vivo experiments, this work demonstrates that the trained network restores the true object size, reduces the noise level and artifacts, improves the contrast at deep regions, and reveals vessels subject to limited view distortion. With these enhancements, 3DFD U-net successfully produces clear 3D vascular images of the palm, arms, breasts, and feet of human subjects. These enhanced vascular images offer improved capabilities for biometric identification, foot ulcer evaluation, and breast cancer imaging. These results indicate that the new algorithm will have a significant impact on preclinical and clinical photoacoustic tomography.
Collapse
Affiliation(s)
- Wenhan Zheng
- Department of Biomedical EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
| | - Huijuan Zhang
- Department of Biomedical EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
| | - Chuqin Huang
- Department of Biomedical EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
| | - Varun Shijo
- Department of Biomedical EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
- Department of Computer Science and EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
| | - Chenhan Xu
- Department of Computer Science and EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
| | - Wenyao Xu
- Department of Computer Science and EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
| | - Jun Xia
- Department of Biomedical EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
- Department of Computer Science and EngineeringUniversity at BuffaloThe State University of New YorkBuffaloNew YorkNY14260USA
| |
Collapse
|
13
|
He H, Fasoula NA, Karlas A, Omar M, Aguirre J, Lutz J, Kallmayer M, Füchtenbusch M, Eckstein HH, Ziegler A, Ntziachristos V. Opening a window to skin biomarkers for diabetes stage with optoacoustic mesoscopy. LIGHT, SCIENCE & APPLICATIONS 2023; 12:231. [PMID: 37718348 PMCID: PMC10505608 DOI: 10.1038/s41377-023-01275-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 08/10/2023] [Accepted: 08/28/2023] [Indexed: 09/19/2023]
Abstract
Being the largest and most accessible organ of the human body, the skin could offer a window to diabetes-related complications on the microvasculature. However, skin microvasculature is typically assessed by histological analysis, which is not suited for applications to large populations or longitudinal studies. We introduce ultra-wideband raster-scan optoacoustic mesoscopy (RSOM) for precise, non-invasive assessment of diabetes-related changes in the dermal microvasculature and skin micro-anatomy, resolved with unprecedented sensitivity and detail without the need for contrast agents. Providing unique imaging contrast, we explored a possible role for RSOM as an investigational tool in diabetes healthcare and offer the first comprehensive study investigating the relationship between different diabetes complications and microvascular features in vivo. We applied RSOM to scan the pretibial area of 95 participants with diabetes mellitus and 48 age-matched volunteers without diabetes, grouped according to disease complications, and extracted six label-free optoacoustic biomarkers of human skin, including dermal microvasculature density and epidermal parameters, based on a novel image-processing pipeline. We then correlated these biomarkers to disease severity and found statistically significant effects on microvasculature parameters as a function of diabetes complications. We discuss how label-free RSOM biomarkers can lead to a quantitative assessment of the systemic effects of diabetes and its complications, complementing the qualitative assessment allowed by current clinical metrics, possibly leading to a precise scoring system that captures the gradual evolution of the disease.
Collapse
Affiliation(s)
- Hailong He
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Nikolina-Alexia Fasoula
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Angelos Karlas
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
- Department for Vascular and Endovascular Surgery, Klinikum rechts der Isar, Technical University of Munich (TUM), Munich, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany
| | - Murad Omar
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Juan Aguirre
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Jessica Lutz
- Diabetes Center at Marienplatz, Munich, Germany
- Forschergruppe Diabetes e.V., Helmholtz Zentrum München, Neuherberg, Germany
| | - Michael Kallmayer
- Department for Vascular and Endovascular Surgery, Klinikum rechts der Isar, Technical University of Munich (TUM), Munich, Germany
| | - Martin Füchtenbusch
- Diabetes Center at Marienplatz, Munich, Germany
- Forschergruppe Diabetes e.V., Helmholtz Zentrum München, Neuherberg, Germany
| | - Hans-Henning Eckstein
- Department for Vascular and Endovascular Surgery, Klinikum rechts der Isar, Technical University of Munich (TUM), Munich, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany
| | - Annette Ziegler
- Forschergruppe Diabetes e.V., Helmholtz Zentrum München, Neuherberg, Germany
- Institute of Diabetes Research, Helmholtz Zentrum München, Neuherberg, Germany
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany.
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany.
- DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany.
| |
Collapse
|
14
|
Jin H, Zheng Z, Cui Z, Jiang Y, Chen G, Li W, Wang Z, Wang J, Yang C, Song W, Chen X, Zheng Y. A flexible optoacoustic blood 'stethoscope' for noninvasive multiparametric cardiovascular monitoring. Nat Commun 2023; 14:4692. [PMID: 37542045 PMCID: PMC10403590 DOI: 10.1038/s41467-023-40181-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Accepted: 07/13/2023] [Indexed: 08/06/2023] Open
Abstract
Quantitative and multiparametric blood analysis is of great clinical importance in cardiovascular disease diagnosis. Although there are various methods to extract blood information, they often require invasive procedures, lack continuity, involve bulky instruments, or have complicated testing procedures. Flexible sensors can realize on-skin assessment of several vital signals, but generally exhibit limited function to monitor blood characteristics. Here, we report a flexible optoacoustic blood 'stethoscope' for noninvasive, multiparametric, and continuous cardiovascular monitoring, without requiring complicated procedures. The optoacoustic blood 'stethoscope' features the light delivery elements to illuminate blood and the piezoelectric acoustic elements to capture light-induced acoustic waves. We show that the optoacoustic blood 'stethoscope' can adhere to the skin for continuous and non-invasive in-situ monitoring of multiple cardiovascular biomarkers, including hypoxia, intravascular exogenous agent concentration decay, and hemodynamics, which can be further visualized with a tailored 3D algorithm. Demonstrations on both in-vivo animal trials and human subjects highlight the optoacoustic blood 'stethoscope''s potential for cardiovascular disease diagnosis and prediction.
Collapse
Affiliation(s)
- Haoran Jin
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, 639798, Singapore
- The State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Zesheng Zheng
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, 639798, Singapore
- Institute of Microelectronics, Agency for Science, Technology and Research, Singapore, 138634, Singapore
| | - Zequn Cui
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Ying Jiang
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Geng Chen
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Wenlong Li
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Zhimin Wang
- School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore, 637371, Singapore
| | - Jilei Wang
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Chuanshi Yang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Weitao Song
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Xiaodong Chen
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore.
| | - Yuanjin Zheng
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, 639798, Singapore.
| |
Collapse
|
15
|
Nagli M, Moisseev R, Suleymanov N, Kaminski E, Hazan Y, Gelbert G, Goykhman I, Rosenthal A. Silicon photonic acoustic detector (SPADE) using a silicon nitride microring resonator. PHOTOACOUSTICS 2023; 32:100527. [PMID: 37645254 PMCID: PMC10461202 DOI: 10.1016/j.pacs.2023.100527] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/14/2023] [Accepted: 06/30/2023] [Indexed: 08/31/2023]
Abstract
Silicon photonics is an emerging platform for acoustic sensing, offering exceptional miniaturization and sensitivity. While efforts have focused on silicon-based resonators, silicon nitride resonators can potentially achieve higher Q-factors, further enhancing sensitivity. In this work, a 30 µm silicon nitride microring resonator was fabricated and coated with an elastomer to optimize acoustic sensitivity and signal fidelity. The resonator was characterized acoustically, and its capability for optoacoustic tomography was demonstrated. An acoustic bandwidth of 120 MHz and a noise-equivalent pressure of ∼ 7 mPa/Hz1/2 were demonstrated. The spatially dependent impulse response agreed with theoretical predictions, and spurious acoustic signals, such as reverberations and surface acoustic waves, had a marginal impact. High image fidelity optoacoustic tomography of a 20 µm knot was achieved, confirming the detector's imaging capabilities. The results show that silicon nitride offers low signal distortion and high-resolution optoacoustic imaging, proving its versatility for acoustic imaging applications.
Collapse
Affiliation(s)
- Michael Nagli
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion – Israel Institute of Technology, Technion City 32000, Haifa, Israel
| | - Ron Moisseev
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion – Israel Institute of Technology, Technion City 32000, Haifa, Israel
| | - Nathan Suleymanov
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion – Israel Institute of Technology, Technion City 32000, Haifa, Israel
| | - Eitan Kaminski
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion – Israel Institute of Technology, Technion City 32000, Haifa, Israel
| | - Yoav Hazan
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion – Israel Institute of Technology, Technion City 32000, Haifa, Israel
| | - Gil Gelbert
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion – Israel Institute of Technology, Technion City 32000, Haifa, Israel
| | - Ilya Goykhman
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion – Israel Institute of Technology, Technion City 32000, Haifa, Israel
| | - Amir Rosenthal
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion – Israel Institute of Technology, Technion City 32000, Haifa, Israel
| |
Collapse
|
16
|
Liang S, Yao J, Liu D, Rao L, Chen X, Wang Z. Harnessing Nanomaterials for Cancer Sonodynamic Immunotherapy. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2211130. [PMID: 36881527 DOI: 10.1002/adma.202211130] [Citation(s) in RCA: 35] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 02/12/2023] [Indexed: 06/18/2023]
Abstract
Immunotherapy has made remarkable strides in cancer therapy over the past decade. However, such emerging therapy still suffers from the low response rates and immune-related adverse events. Various strategies have been developed to overcome these serious challenges. Therein, sonodynamic therapy (SDT), as a non-invasive treatment, has received ever-increasing attention especially in the treatment of deep-seated tumors. Significantly, SDT can effectively induce immunogenic cell death to trigger systemic anti-tumor immune response, termed sonodynamic immunotherapy. The rapid development of nanotechnology has revolutionized SDT effects with robust immune response induction. As a result, more and more innovative nanosonosensitizers and synergistic treatment modalities are established with superior efficacy and safe profile. In this review, the recent advances in cancer sonodynamic immunotherapy are summarized with a particular emphasis on how nanotechnology can be explored to harness SDT for amplifying anti-tumor immune response. Moreover, the current challenges in this field and the prospects for its clinical translation are also presented. It is anticipated that this review can provide rational guidance and facilitate the development of nanomaterials-assisted sonodynamic immunotherapy, helping to pave the way for next-generation cancer therapy and eventually achieve a durable response in patients.
Collapse
Affiliation(s)
- Shuang Liang
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China
- Beijing Key Laboratory of Drug Delivery Technology and Novel Formulation, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China
| | - Jianjun Yao
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China
- Beijing Key Laboratory of Drug Delivery Technology and Novel Formulation, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China
- School of Life Sciences and Biopharmaceutical Science, Shenyang Pharmaceutical University, Shenyang, 110016, China
| | - Dan Liu
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China
- Beijing Key Laboratory of Drug Delivery Technology and Novel Formulation, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China
| | - Lang Rao
- Institute of Biomedical Health Technology and Engineering, Shenzhen Bay Laboratory, Shenzhen, 518132, China
| | - Xiaoyuan Chen
- Departments of Diagnostic Radiology, Surgery, Chemical and Biomolecular Engineering, and Biomedical Engineering, Yong Loo Lin School of Medicine and College of Design and Engineering, National University of Singapore, Singapore, 119074
- Clinical Imaging Research Centre, Centre for Translational Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, 117599, Singapore
- Nanomedicine Translational Research Program, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, 117597, Singapore
- Institute of Molecular and Cell Biology, Agency for Science, Technology, and Research (A*STAR), 61 Biopolis Drive, Proteos, Singapore, 138673, Singapore
| | - Zhaohui Wang
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China
- Beijing Key Laboratory of Drug Delivery Technology and Novel Formulation, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China
| |
Collapse
|
17
|
Harary T, Hazan Y, Rosenthal A. All-optical optoacoustic micro-tomography in reflection mode. Biomed Eng Lett 2023; 13:475-483. [PMID: 37519878 PMCID: PMC10382435 DOI: 10.1007/s13534-023-00278-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 03/17/2023] [Accepted: 04/03/2023] [Indexed: 08/01/2023] Open
Abstract
High-resolution optoacoustic imaging at depths beyond the optical diffusion limit is conventionally performed using a microscopy setup where a strongly focused ultrasound transducer samples the image object point-by-point. Although recent advancements in miniaturized ultrasound detectors enables one to achieve microscopic resolution with an unfocused detector in a tomographic configuration, such an approach requires illuminating the entire object, leading to an inefficient use of the optical power, and imposing a trans-illumination configuration that is limited to thin objects. We developed an optoacoustic micro-tomography system in an epi-illumination configuration, in which the illumination is scanned with the detector. The system is demonstrated in phantoms for imaging depths of up to 5 mm and in vivo for imaging the vasculature of a mouse ear. Although image-formation in optoacoustic tomography generally requires static illumination, our numerical simulations and experimental measurements show that this requirement is relaxed in practice due to light diffusion, which homogenizes the fluence in deep tissue layers.
Collapse
Affiliation(s)
- Tamar Harary
- Andrew and Erna Viterbi Faculty of Electrical & Computer Engineering, Technion – Israel Institute of Technology, Technion City, Haifa, 32000 Israel
| | - Yoav Hazan
- Andrew and Erna Viterbi Faculty of Electrical & Computer Engineering, Technion – Israel Institute of Technology, Technion City, Haifa, 32000 Israel
| | - Amir Rosenthal
- Andrew and Erna Viterbi Faculty of Electrical & Computer Engineering, Technion – Israel Institute of Technology, Technion City, Haifa, 32000 Israel
| |
Collapse
|
18
|
Guo T, Xiong K, Yuan B, Zhang Z, Wang L, Zhang Y, Liang C, Liu Z. Homogeneous-resolution photoacoustic microscopy for ultrawide field-of-view neurovascular imaging in Alzheimer's disease. PHOTOACOUSTICS 2023; 31:100516. [PMID: 37313359 PMCID: PMC10258506 DOI: 10.1016/j.pacs.2023.100516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/25/2023] [Accepted: 05/25/2023] [Indexed: 06/15/2023]
Abstract
Neurovascular imaging is essential for investigating neurodegenerative diseases. However, the existing neurovascular imaging technology suffers from a trade-off between a field of view (FOV) and resolution in the whole brain, resulting in an inhomogeneous resolution and lack of information. Here, homogeneous-resolution arched-scanning photoacoustic microscopy (AS-PAM), which has an ultrawide FOV to cover the entire mouse cerebral cortex, was developed. Imaging of the neurovasculature was performed with a homogenous resolution of 6.9 µm from the superior sagittal sinus to the middle cerebral artery and caudal rhinal vein in an FOV of 12 × 12 mm2. Moreover, using AS-PAM, vascular features of the meninges and cortex were quantified in early Alzheimer's disease (AD) and wild-type (WT) mice. The results demonstrated high sensitivity to the pathological progression of AD on tortuosity and branch index. The high-fidelity imaging capability in large FOV enables AS-PAM to be a promising tool for precise brain neurovascular visualization and quantification.
Collapse
Affiliation(s)
- Ting Guo
- School of Medicine South China University of Technology, Guangzhou 510006, China
- Department of Radiology, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 510080, China
- Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangzhou 510080, China
| | - Kedi Xiong
- MOE Key Laboratory of Laser Life Science Institute of Laser Life Science, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Bo Yuan
- MOE Key Laboratory of Laser Life Science Institute of Laser Life Science, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Zhenhui Zhang
- MOE Key Laboratory of Laser Life Science Institute of Laser Life Science, South China Normal University, Guangzhou 510631, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Lijuan Wang
- Department of Radiology, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 510080, China
- Guangzhou Key Laboratory of Diagnosis and Treatment for Neurodegenerative Diseases, Guangzhou 510080, China
| | - Yuhu Zhang
- Department of Radiology, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 510080, China
- Guangzhou Key Laboratory of Diagnosis and Treatment for Neurodegenerative Diseases, Guangzhou 510080, China
| | - Changhong Liang
- Department of Radiology, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 510080, China
- Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangzhou 510080, China
| | - Zaiyi Liu
- Department of Radiology, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 510080, China
- Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangzhou 510080, China
| |
Collapse
|
19
|
Hacker L, Brown EL, Lefebvre TL, Sweeney PW, Bohndiek SE. Performance evaluation of mesoscopic photoacoustic imaging. PHOTOACOUSTICS 2023; 31:100505. [PMID: 37214427 PMCID: PMC10199419 DOI: 10.1016/j.pacs.2023.100505] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/05/2023] [Accepted: 05/05/2023] [Indexed: 05/24/2023]
Abstract
Photoacoustic mesoscopy visualises vascular architecture at high-resolution up to ~3 mm depth. Despite promise in preclinical and clinical imaging studies, with applications in oncology and dermatology, the accuracy and precision of photoacoustic mesoscopy is not well established. Here, we evaluate a commercial photoacoustic mesoscopy system for imaging vascular structures. Typical artefact types are first highlighted and limitations due to non-isotropic illumination and detection are evaluated with respect to rotation, angularity, and depth of the target. Then, using tailored phantoms and mouse models, we investigate system precision, showing coefficients of variation (COV) between repeated scans [short term (1 h): COV= 1.2%; long term (25 days): COV= 9.6%], from target repositioning (without: COV=1.2%, with: COV=4.1%), or from varying in vivo user experience (experienced: COV=15.9%, unexperienced: COV=20.2%). Our findings show robustness of the technique, but also underscore general challenges of limited-view photoacoustic systems in accurately imaging vessel-like structures, thereby guiding users when interpreting biologically-relevant information.
Collapse
Affiliation(s)
- Lina Hacker
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Emma L. Brown
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Thierry L. Lefebvre
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Paul W. Sweeney
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Sarah E. Bohndiek
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| |
Collapse
|
20
|
Buehler A, Brown E, Paulus L, Eckstein M, Thoma O, Oraiopoulou M, Rother U, Hoerning A, Hartmann A, Neurath MF, Woelfle J, Friedrich O, Waldner MJ, Knieling F, Bohndiek SE, Regensburger AP. Transrectal Absorber Guide Raster-Scanning Optoacoustic Mesoscopy for Label-Free In Vivo Assessment of Colitis. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2300564. [PMID: 37083262 PMCID: PMC10288266 DOI: 10.1002/advs.202300564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/21/2023] [Indexed: 05/03/2023]
Abstract
Optoacoustic imaging (OAI) enables microscale imaging of endogenous chromophores such as hemoglobin at significantly higher penetration depths compared to other optical imaging technologies. Raster-scanning optoacoustic mesoscopy (RSOM) has recently been shown to identify superficial microvascular changes associated with human skin pathologies. In animal models, the imaging depth afforded by RSOM can enable entirely new capabilities for noninvasive imaging of vascular structures in the gastrointestinal tract, but exact localization of intra-abdominal organs is still elusive. Herein the development and application of a novel transrectal absorber guide for RSOM (TAG-RSOM) is presented to enable accurate transabdominal localization and assessment of colonic vascular networks in vivo. The potential of TAG-RSOM is demonstrated through application during mild and severe acute colitis in mice. TAG-RSOM enables visualization of transmural vascular networks, with changes in colon wall thickness, blood volume, and OAI signal intensities corresponding to colitis-associated inflammatory changes. These findings suggest TAG-RSOM can provide a novel monitoring tool in preclinical IBD models, refining animal procedures and underlines the capabilities of such technologies to address inflammatory bowel diseases in humans.
Collapse
Affiliation(s)
- Adrian Buehler
- Department of Pediatrics and Adolescent MedicineUniversity Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| | - Emma Brown
- Department of Physics and Cancer Research UK Cambridge InstituteUniversity of CambridgeCambridgeCB2 0REUK
| | - Lars‐Philip Paulus
- Department of Pediatrics and Adolescent MedicineUniversity Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| | - Markus Eckstein
- Institute of PathologyFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| | - Oana‐Maria Thoma
- Department of Medicine 1University Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91052ErlangenGermany
| | - Mariam‐Eleni Oraiopoulou
- Department of Physics and Cancer Research UK Cambridge InstituteUniversity of CambridgeCambridgeCB2 0REUK
| | - Ulrich Rother
- Department of Vascular SurgeryUniversity Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| | - André Hoerning
- Department of Pediatrics and Adolescent MedicineUniversity Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| | - Arndt Hartmann
- Institute of PathologyFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| | - Markus F. Neurath
- Department of Medicine 1University Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91052ErlangenGermany
| | - Joachim Woelfle
- Department of Pediatrics and Adolescent MedicineUniversity Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| | - Oliver Friedrich
- Institute of Medical BiotechnologyDepartment of Chemical and Biological EngineeringFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91052ErlangenGermany
| | - Maximilian J. Waldner
- Department of Medicine 1University Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91052ErlangenGermany
| | - Ferdinand Knieling
- Department of Pediatrics and Adolescent MedicineUniversity Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| | - Sarah E. Bohndiek
- Department of Physics and Cancer Research UK Cambridge InstituteUniversity of CambridgeCambridgeCB2 0REUK
| | - Adrian P. Regensburger
- Department of Pediatrics and Adolescent MedicineUniversity Hospital ErlangenFriedrich‐Alexander‐Universität (FAU) Erlangen‐Nürnberg91054ErlangenGermany
| |
Collapse
|
21
|
Nau T, Schönmann C, Hindelang B, Riobo L, Doll A, Schneider S, Englert L, He H, Biedermann T, Darsow U, Lauffer F, Ntziachristos V, Aguirre J. Raster-scanning optoacoustic mesoscopy biomarkers for atopic dermatitis skin lesions. PHOTOACOUSTICS 2023; 31:100513. [PMID: 37275325 PMCID: PMC10236218 DOI: 10.1016/j.pacs.2023.100513] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 05/10/2023] [Accepted: 05/19/2023] [Indexed: 06/07/2023]
Abstract
Atopic dermatitis (AD) is the most common chronic inflammatory skin disease worldwide. Its severity is assessed using scores that rely on visual observation of the affected body surface area, the morphology of the lesions and subjective symptoms, like pruritus or insomnia. Ideally, such scores should be complemented by objective and accurate measurements of disease severity to standardize disease scoring in routine care and clinical trials. Recently, it was shown that raster-scanning optoacoustic mesoscopy (RSOM) can provide detailed three-dimensional images of skin inflammation processes that capture the most relevant features of their pathology. Moreover, precise RSOM biomarkers of inflammation have been identified for psoriasis. However, the objectivity and validity of such biomarkers in repeated measurements have not yet been assessed for AD. Here, we report the results of a study on the repeatability of RSOM inflammation biomarkers in AD to estimate their precision. Optoacoustic imaging analysis revealed morphological inflammation biomarkers with precision well beyond standard clinical severity metrics. Our findings suggest that optoacoustic mesoscopy may be a good choice for quantitative evaluations of AD that are inaccessible by other methods. This could potentially enable the optimization of disease scoring and drug development.
Collapse
Affiliation(s)
- T. Nau
- Department of Dermatology and Allergology, Technical University of Munich, Munich, Germany
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
| | - C. Schönmann
- Department of Dermatology and Allergology, Technical University of Munich, Munich, Germany
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
| | - B. Hindelang
- Department of Dermatology and Allergology, Technical University of Munich, Munich, Germany
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
| | - L. Riobo
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
| | - A. Doll
- Department of Dermatology and Allergology, Technical University of Munich, Munich, Germany
| | - S. Schneider
- Department of Dermatology and Allergology, Technical University of Munich, Munich, Germany
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
| | - L. Englert
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
| | - H. He
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
| | - T. Biedermann
- Department of Dermatology and Allergology, Technical University of Munich, Munich, Germany
| | - U. Darsow
- Department of Dermatology and Allergology, Technical University of Munich, Munich, Germany
| | - F. Lauffer
- Department of Dermatology and Allergology, Technical University of Munich, Munich, Germany
| | - V. Ntziachristos
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
- Munich Institute of Robotics and Machine Intelligence (MIRMI), Technical University of Munich, 81675 Munich, Germany
| | - J. Aguirre
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764 Neuherberg, Germany
- Departamento de Tecnología Electrónica y de las Comunicaciones, Universidad Autonoma de Madrid, Madrid, Spain
- Instituto de Investigacion Sanitaria de la Fundacion Jimenez Diaz, Madrid, Spain
| |
Collapse
|
22
|
Ma J, Zhao J, Chen H, Sun LP, Li J, Guan BO. Transparent microfiber Fabry-Perot ultrasound sensor with needle-shaped focus for multiscale photoacoustic imaging. PHOTOACOUSTICS 2023; 30:100482. [PMID: 37025114 PMCID: PMC10070891 DOI: 10.1016/j.pacs.2023.100482] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/01/2023] [Accepted: 03/26/2023] [Indexed: 06/19/2023]
Abstract
Photoacoustic tomography emerged as a promising tool for noninvasive biomedical imaging and diseases diagnosis. However, most of the current piezoelectric ultrasound transducers suffer optical opacity and tissue-mismatched acoustic impedance, hindering the miniaturization and integration of the system for multiscale and multimodal imaging. Here, a transparent polydimethylsiloxane (PDMS) encapsulated optical microfiber ultrasound sensor was demonstrated for photoacoustic imaging with scalable spatial resolution and penetration depth. The sensor comprised a microfiber loop sandwiched by a pair of in-line Bragg gratings, which formed an ultrasound-sensitive Fabry-Perot cavity allowing free delivery of ultrasound/light beams and unique needle-shaped ultrasound focusing along the penetration depth. The sensor with a detection limit of ∼ 700 Pa and a bandwidth of ∼ 10 MHz was applied for multiscale photoacoustic imaging of mouse ear and brain vasculatures. With advantages of flexibility, optical transparence and focusing capability, the sensor offers new opportunities for developing photoacoustic/ultrasound imaging devices for biomedical and clinic applications.
Collapse
|
23
|
Wang Z, Tong Z, Chen H, Nie G, Hu J, Liu W, Wang E, Yuan B, Wang Z, Hu J. Photoacoustic/ultrasonic dual-mode imaging for monitoring angiogenesis and synovial erosion in rheumatoid arthritis. PHOTOACOUSTICS 2023; 29:100458. [PMID: 36816882 PMCID: PMC9929594 DOI: 10.1016/j.pacs.2023.100458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 02/03/2023] [Accepted: 02/05/2023] [Indexed: 02/08/2023]
Abstract
Rheumatoid arthritis (RA) is a chronic autoimmune disease characterized by the formation of new vessels, synovial proliferation and destruction of articular cartilage. However, characteristic early diagnostic and therapeutic monitoring methods are still lacking. We report a study using a photoacoustic/ultrasound (PA/US) dual-mode imaging for RA disease. By establishing a collagen-induced (CIA) RA mouse model to classify disease states based on a subjective grading system, PA/US imaging allows real-time assessment of synovial erosion and vascular opacification within the knee joint in different disease states at high spatial resolution. The system also quantitatively monitors subcutaneous vascular physiology and morphology in the hind paw of mice, measuring the area and photoacoustic signal intensity of vascular proliferation and showing a positive correlation with disease grading. Compared to traditional subjective scoring of arthritis severity, the PA/US imaging is more sensitive i.e., vascular signals and synovial erosion can be observed early in the course of arthritis.
Collapse
Affiliation(s)
- Zhen Wang
- Department of Orthopaedics, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
- Orthopaedic Medical Research Center, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
| | - Zhuangzhuang Tong
- MOE Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, PR China
| | - Hongjiang Chen
- Department of Orthopaedics, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
- Orthopaedic Medical Research Center, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
| | - Guangshuai Nie
- Department of Orthopaedics, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
- Orthopaedic Medical Research Center, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
| | - Jia Hu
- Department of Orthopaedics, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
- Orthopaedic Medical Research Center, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
| | - Weiyang Liu
- Department of Orthopaedics, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
- Orthopaedic Medical Research Center, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
| | - Erqi Wang
- MOE Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, PR China
| | - Bo Yuan
- MOE Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, PR China
| | - Zhiyang Wang
- MOE Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, PR China
- Corresponding author.
| | - Jun Hu
- Department of Orthopaedics, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
- Orthopaedic Medical Research Center, The First Affiliated Hospital of Shantou University Medical College, Shantou, PR China
- Correspondence to: Department of Orthopaedics, First Affiliated Hospital of Shantou University Medical College, Shantou, PR China.
| |
Collapse
|
24
|
Wang Z, Yang F, Zhang W, Xiong K, Yang S. Towards in vivo photoacoustic human imaging: shining a new light on clinical diagnostics. FUNDAMENTAL RESEARCH 2023. [DOI: 10.1016/j.fmre.2023.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
|
25
|
Hofmann UA, Li W, Deán-Ben XL, Subochev P, Estrada H, Razansky D. Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction. PHOTOACOUSTICS 2022; 28:100405. [PMID: 36246932 PMCID: PMC9554813 DOI: 10.1016/j.pacs.2022.100405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 09/19/2022] [Accepted: 09/22/2022] [Indexed: 06/16/2023]
Abstract
Optoacoustic mesoscopy combines rich optical absorption contrast with high spatial resolution at tissue depths beyond reach for microscopic techniques employing focused light excitation. The mesoscopic imaging performance is commonly hindered by the use of inaccurate delay-and-sum reconstruction approaches and idealized modeling assumptions. In principle, image reconstruction performance could be enhanced by simulating the optoacoustic signal generation, propagation, and detection path. However, for most realistic experimental scenarios, the underlying total impulse response (TIR) cannot be accurately modelled. Here we propose to capture the TIR by scanning of a sub-resolution sized absorber. Significant improvement of spatial resolution and depth uniformity is demonstrated over 3 mm range, outperforming delay-and-sum and model-based reconstruction implementations. Reconstruction performance is validated by imaging subcutaneous murine vasculature and human skin in vivo. The proposed experimental calibration and reconstruction paradigm facilitates quantitative inversions while averting complex physics-based simulations. It can readily be applied to other imaging modalities employing TIR-based reconstructions.
Collapse
Affiliation(s)
- Urs A.T. Hofmann
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Weiye Li
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Xosé Luís Deán-Ben
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Pavel Subochev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Héctor Estrada
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Daniel Razansky
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| |
Collapse
|
26
|
Geisler EL, Brannen A, Pressler M, Perez J, Kane AA, Hallac RR. 3D imaging of vascular anomalies using raster-scanning optoacoustic mesoscopy. Lasers Surg Med 2022; 54:1269-1277. [PMID: 35870193 DOI: 10.1002/lsm.23588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 06/18/2022] [Accepted: 07/13/2022] [Indexed: 12/30/2022]
Abstract
OBJECTIVES Vascular anomalies such as capillary malformations (CMs) and infantile hemangiomas (IHs) are common pediatric vascular disorders that are treated with therapeutic laser. The treatment method, however, relies on subjective evaluation of clinical findings and can have unpredictable results. Raster-scanning optoacoustic mesoscopy (RSOM) is an innovative imaging technology using pulsed-light laser to excite hemoglobin, generating ultrasound waves that are converted into three-dimensional images of tissues. RSOM can provide objective information about superficial structures such as the microvasculature of vascular anomalies. MATERIALS AND METHODS In this study, we explore the clinical potential of RSOM to study vascular anomalies before and after laser treatment. We scanned nine patients with CM (n = 6) and IH (n = 3) who underwent laser treatment and calculated the blood vessel volume. RESULTS Overall, there was a posttreatment volume increase in CM, and a decrease in IH. CONCLUSION These findings support the possibility that RSOM may have a role in developing an objective method of evaluating these lesions, leading to a tailored treatment approach and avoidance of adverse outcomes.
Collapse
Affiliation(s)
- Emily L Geisler
- University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | | | - Mark Pressler
- University of Texas Southwestern Medical Center, Dallas, Texas, USA.,University of Virginia School of Medicine, Charlottesville, Virginia, USA
| | - Jeyna Perez
- University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Alex A Kane
- University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Analytical Imaging and Modeling Center, Children's Health, Dallas, Texas, USA
| | - Rami R Hallac
- University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Analytical Imaging and Modeling Center, Children's Health, Dallas, Texas, USA
| |
Collapse
|
27
|
Zhou Q, Nozdriukhin D, Chen Z, Glandorf L, Hofmann UAT, Reiss M, Tang L, Deán‐Ben XL, Razansky D. Depth-Resolved Localization Microangiography in the NIR-II Window. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 10:e2204782. [PMID: 36403231 PMCID: PMC9811471 DOI: 10.1002/advs.202204782] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 10/17/2022] [Indexed: 06/16/2023]
Abstract
Detailed characterization of microvascular alterations requires high-resolution 3D imaging methods capable of providing both morphological and functional information. Existing optical microscopy tools are routinely used for microangiography, yet offer suboptimal trade-offs between the achievable field of view and spatial resolution with the intense light scattering in biological tissues further limiting the achievable penetration depth. Herein, a new approach for volumetric deep-tissue microangiography based on stereovision combined with super-resolution localization imaging is introduced that overcomes the spatial resolution limits imposed by light diffusion and optical diffraction in wide-field imaging configurations. The method capitalizes on localization and tracking of flowing fluorescent particles in the second near-infrared window (NIR-II, ≈1000-1700 nm), with the third (depth) dimension added by triangulation and stereo-matching of images acquired with two short-wave infrared cameras operating in a dual-view mode. The 3D imaging capability enabled with the proposed method facilitates a detailed visualization of microvascular networks and an accurate blood flow quantification. Experiments performed in tissue-mimicking phantoms demonstrate that high resolution is preserved up to a depth of 4 mm in a turbid medium. Transcranial microangiography of the entire murine cortex and penetrating vessels is further demonstrated at capillary level resolution.
Collapse
Affiliation(s)
- Quanyu Zhou
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Daniil Nozdriukhin
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Zhenyue Chen
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Lukas Glandorf
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Urs A. T. Hofmann
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Michael Reiss
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Lin Tang
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Xosé Luís Deán‐Ben
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Daniel Razansky
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| |
Collapse
|
28
|
Dimaridis I, Sridharan P, Ntziachristos V, Karlas A, Hadjileontiadis L. Image Quality Improvement Techniques and Assessment Adequacy in Clinical Optoacoustic Imaging: A Systematic Review. BIOSENSORS 2022; 12:901. [PMID: 36291038 PMCID: PMC9599915 DOI: 10.3390/bios12100901] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/09/2022] [Accepted: 09/17/2022] [Indexed: 06/16/2023]
Abstract
Optoacoustic imaging relies on the detection of optically induced acoustic waves to offer new possibilities in morphological and functional imaging. As the modality matures towards clinical application, research efforts aim to address multifactorial limitations that negatively impact the resulting image quality. In an endeavor to obtain a clear view on the limitations and their effects, as well as the status of this progressive refinement process, we conduct an extensive search for optoacoustic image quality improvement approaches that have been evaluated with humans in vivo, thus focusing on clinically relevant outcomes. We query six databases (PubMed, Scopus, Web of Science, IEEE Xplore, ACM Digital Library, and Google Scholar) for articles published from 1 January 2010 to 31 October 2021, and identify 45 relevant research works through a systematic screening process. We review the identified approaches, describing their primary objectives, targeted limitations, and key technical implementation details. Moreover, considering comprehensive and objective quality assessment as an essential prerequisite for the adoption of such approaches in clinical practice, we subject 36 of the 45 papers to a further in-depth analysis of the reported quality evaluation procedures, and elicit a set of criteria with the intent to capture key evaluation aspects. Through a comparative criteria-wise rating process, we seek research efforts that exhibit excellence in quality assessment of their proposed methods, and discuss features that distinguish them from works with similar objectives. Additionally, informed by the rating results, we highlight areas with improvement potential, and extract recommendations for designing quality assessment pipelines capable of providing rich evidence.
Collapse
Affiliation(s)
- Ioannis Dimaridis
- Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Patmaa Sridharan
- Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany
- Munich Institute of Robotics and Machine Intelligence (MIRMI), Technical University of Munich, 80992 Munich, Germany
- German Centre for Cardiovascular Research (DZHK), partner site Munich Heart Alliance, 80636 Munich, Germany
| | - Angelos Karlas
- Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, 81675 Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany
- German Centre for Cardiovascular Research (DZHK), partner site Munich Heart Alliance, 80636 Munich, Germany
- Clinic for Vascular and Endovascular Surgery, Klinikum rechts der Isar, 81675 Munich, Germany
| | - Leontios Hadjileontiadis
- Department of Biomedical Engineering, Khalifa University, Abu Dhabi P.O. Box 127788, United Arab Emirates
- Healthcare Engineering Innovation Center (HEIC), Khalifa University, Abu Dhabi P.O. Box 127788, United Arab Emirates
- Signal Processing and Biomedical Technology Unit, Telecommunications Laboratory, Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
29
|
Englert L, Riobo L, Schönmann C, Ntziachristos V, Aguirre J. Enabling the autofocus approach for parameter optimization in planar measurement geometry clinical optoacoustic imaging. JOURNAL OF BIOPHOTONICS 2022; 15:e202200032. [PMID: 35599314 DOI: 10.1002/jbio.202200032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 04/10/2022] [Accepted: 05/11/2022] [Indexed: 06/15/2023]
Abstract
In optoacoustic (photoacoustic) tomography, several parameters related to tissue and detector features are needed for image formation, but they may not be known a priori. An autofocus (AF) algorithm is generally used to estimate these parameters. However, the algorithm works iteratively and is therefore impractical for clinical imaging with planar geometry systems due to the long reconstruction times. We have developed a fast autofocus (FAF) algorithm for 3D optoacoustic systems with planar geometry. Such an algorithm exploits the symmetries of the planar geometry and a virtual source concept to reduce the dimensionality of the parameter estimation problem. The dimensionality reduction makes FAF much simpler computationally than the conventional AF algorithm. We show that the FAF algorithm required about 5 s to provide accurate estimates of the speed of sound in simulated data and experimental data obtained using an imaging system that is poised to enter the clinic. The applicability of FAF for estimating other image formation parameters is discussed. We expect the FAF algorithm to contribute decisively to the clinical use of optoacoustic tomography systems with planar geometry.
Collapse
Affiliation(s)
- Ludwig Englert
- Chair of Biological Imaging, Technical University of Munich, Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, Neuherberg, Germany
| | - Lucas Riobo
- Chair of Biological Imaging, Technical University of Munich, Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, Neuherberg, Germany
| | - Christine Schönmann
- Chair of Biological Imaging, Technical University of Munich, Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, Neuherberg, Germany
- Department of Dermatology and Allergy, Technical University of Munich, Munich, Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging, Technical University of Munich, Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, Neuherberg, Germany
- Munich Institute of Robotics and Machine Intelligence (MIRMI), Technical University of Munich, Munich, Germany
| | - Juan Aguirre
- Chair of Biological Imaging, Technical University of Munich, Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, Neuherberg, Germany
| |
Collapse
|
30
|
Frequency wavelength multiplexed optoacoustic tomography. Nat Commun 2022; 13:4448. [PMID: 35915111 PMCID: PMC9343396 DOI: 10.1038/s41467-022-32175-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 07/20/2022] [Indexed: 11/11/2022] Open
Abstract
Optoacoustics (OA) is overwhelmingly implemented in the Time Domain (TD) to achieve high signal-to-noise ratios by maximizing the excitation light energy transient. Implementations in the Frequency Domain (FD) have been proposed, but suffer from low signal-to-noise ratios and have not offered competitive advantages over time domain methods to reach high dissemination. It is therefore commonly believed that TD is the optimal way to perform optoacoustics. Here we introduce an optoacoustic concept based on pulse train illumination and frequency domain multiplexing and theoretically demonstrate the superior merits of the approach compared to the time domain. Then, using recent advances in laser diode illumination, we launch Frequency Wavelength Multiplexing Optoacoustic Tomography (FWMOT), at multiple wavelengths, and experimentally showcase how FWMOT optimizes the signal-to-noise ratios of spectral measurements over time-domain methods in phantoms and in vivo. We further find that FWMOT offers the fastest multi-spectral operation ever demonstrated in optoacoustics. Optoacoustic imaging is mostly performed in the time domain. Here the authors demonstrate frequency wavelength multiplexed optoacoustic tomography that can operate at multiple wavelengths simultaneously and offers signal-to-noise ratio advantages over time domain methods.
Collapse
|
31
|
Taylor-Williams M, Spicer G, Bale G, Bohndiek SE. Noninvasive hemoglobin sensing and imaging: optical tools for disease diagnosis. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-220074VR. [PMID: 35922891 PMCID: PMC9346606 DOI: 10.1117/1.jbo.27.8.080901] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/27/2022] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE Measurement and imaging of hemoglobin oxygenation are used extensively in the detection and diagnosis of disease; however, the applied instruments vary widely in their depth of imaging, spatiotemporal resolution, sensitivity, accuracy, complexity, physical size, and cost. The wide variation in available instrumentation can make it challenging for end users to select the appropriate tools for their application and to understand the relative limitations of different methods. AIM We aim to provide a systematic overview of the field of hemoglobin imaging and sensing. APPROACH We reviewed the sensing and imaging methods used to analyze hemoglobin oxygenation, including pulse oximetry, spectral reflectance imaging, diffuse optical imaging, spectroscopic optical coherence tomography, photoacoustic imaging, and diffuse correlation spectroscopy. RESULTS We compared and contrasted the ability of different methods to determine hemoglobin biomarkers such as oxygenation while considering factors that influence their practical application. CONCLUSIONS We highlight key limitations in the current state-of-the-art and make suggestions for routes to advance the clinical use and interpretation of hemoglobin oxygenation information.
Collapse
Affiliation(s)
- Michaela Taylor-Williams
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| | - Graham Spicer
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| | - Gemma Bale
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Electrical Division, Department of Engineering, Cambridge, United Kingdom, United Kingdom
| | - Sarah E Bohndiek
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| |
Collapse
|
32
|
Kim K, Youm JY, Lee EH, Gulenko O, Kim M, Yoon BH, Jeon M, Kim TH, Ha YS, Yang JM. Tapered catheter-based transurethral photoacoustic and ultrasonic endoscopy of the urinary system. OPTICS EXPRESS 2022; 30:26169-26181. [PMID: 36236812 DOI: 10.1364/oe.461855] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 06/13/2022] [Indexed: 06/16/2023]
Abstract
Early diagnosis is critical for treating bladder cancer, as this cancer is very aggressive and lethal if detected too late. To address this important clinical issue, a photoacoustic tomography (PAT)-based transabdominal imaging approach was suggested in previous reports, in which its in vivo feasibility was also demonstrated based on a small animal model. However, successful translation of this approach to real clinical settings would be challenging because the human bladder is located at a depth that far exceeds the typical penetration depth of PAT (∼3 cm for in vivo cases). In this study, we developed a tapered catheter-based, transurethral photoacoustic and ultrasonic endoscopic probe with a 2.8 mm outer diameter to investigate whether the well-known benefits of PAT can be harnessed to resolve unmet urological issues, including early diagnosis of bladder cancer. To demonstrate the in vivo imaging capability of the proposed imaging probe, we performed a rabbit model-based urinary system imaging experiment and acquired a 3D microvasculature map distributed in the wall of the urinary system, which is a first in PAT, to the best of our knowledge. We believe that the results strongly support the use of this transurethral imaging approach as a feasible strategy for addressing urological diagnosis issues.
Collapse
|
33
|
Ni R, Chen Z, Deán-Ben XL, Voigt FF, Kirschenbaum D, Shi G, Villois A, Zhou Q, Crimi A, Arosio P, Nitsch RM, Nilsson KPR, Aguzzi A, Helmchen F, Klohs J, Razansky D. Multiscale optical and optoacoustic imaging of amyloid-β deposits in mice. Nat Biomed Eng 2022; 6:1031-1044. [PMID: 35835994 DOI: 10.1038/s41551-022-00906-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 05/27/2022] [Indexed: 12/26/2022]
Abstract
Deposits of amyloid-β (Aβ) in the brains of rodents can be analysed by invasive intravital microscopy on a submillimetre scale, or via whole-brain images from modalities lacking the resolution or molecular specificity to accurately characterize Aβ pathologies. Here we show that large-field multifocal illumination fluorescence microscopy and panoramic volumetric multispectral optoacoustic tomography can be combined to longitudinally assess Aβ deposits in transgenic mouse models of Alzheimer's disease. We used fluorescent Aβ-targeted probes (the luminescent conjugated oligothiophene HS-169 and the oxazine-derivative AOI987) to transcranially detect Aβ deposits in the cortex of APP/PS1 and arcAβ mice with single-plaque resolution (8 μm) and across the whole brain (including the hippocampus and the thalamus, which are inaccessible by conventional intravital microscopy) at sub-150 μm resolutions. Two-photon microscopy, light-sheet microscopy and immunohistochemistry of brain-tissue sections confirmed the specificity and regional distributions of the deposits. High-resolution multiscale optical and optoacoustic imaging of Aβ deposits across the entire brain in rodents thus facilitates the in vivo study of Aβ accumulation by brain region and by animal age and strain.
Collapse
Affiliation(s)
- Ruiqing Ni
- Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland.,Zurich Neuroscience Center (ZNZ), University of Zurich and ETH Zurich, Zurich, Switzerland.,Institute for Regenerative Medicine, University of Zurich, Zurich, Switzerland
| | - Zhenyue Chen
- Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland.,Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
| | - Xosé Luís Deán-Ben
- Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland.,Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
| | - Fabian F Voigt
- Zurich Neuroscience Center (ZNZ), University of Zurich and ETH Zurich, Zurich, Switzerland.,Brain Research Institute, University of Zurich, Zurich, Switzerland
| | | | - Gloria Shi
- Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland
| | - Alessia Villois
- Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, Switzerland
| | - Quanyu Zhou
- Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland.,Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
| | - Alessandro Crimi
- Institute of Neuropathology, Universitätsspital Zurich, Zurich, Switzerland
| | - Paolo Arosio
- Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, Switzerland
| | - Roger M Nitsch
- Zurich Neuroscience Center (ZNZ), University of Zurich and ETH Zurich, Zurich, Switzerland.,Institute for Regenerative Medicine, University of Zurich, Zurich, Switzerland
| | - K Peter R Nilsson
- Division of Chemistry, Department of Physics, Chemistry and Biology, Linköping University, Linköping, Sweden
| | - Adriano Aguzzi
- Zurich Neuroscience Center (ZNZ), University of Zurich and ETH Zurich, Zurich, Switzerland.,Institute of Neuropathology, Universitätsspital Zurich, Zurich, Switzerland
| | - Fritjof Helmchen
- Zurich Neuroscience Center (ZNZ), University of Zurich and ETH Zurich, Zurich, Switzerland.,Brain Research Institute, University of Zurich, Zurich, Switzerland
| | - Jan Klohs
- Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland. .,Zurich Neuroscience Center (ZNZ), University of Zurich and ETH Zurich, Zurich, Switzerland.
| | - Daniel Razansky
- Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland. .,Zurich Neuroscience Center (ZNZ), University of Zurich and ETH Zurich, Zurich, Switzerland. .,Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland.
| |
Collapse
|
34
|
Li Z, Meng Z, Tian F, Ye Z, Zhou X, Zhong X, Chen Q, Yang M, Liu Z, Yin Y. Fast Fourier Transform-weighted Photoacoustic Imaging by In Vivo Magnetic Alignment of Hybrid Nanorods. NANO LETTERS 2022; 22:5158-5166. [PMID: 35762802 DOI: 10.1021/acs.nanolett.2c00854] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Photoacoustic (PA) imaging uses photon-phonon conversion for high-resolution tomography of biological tissues and functions. Exogenous contrast agents are often added to improve the image quality, but the interference from endogenous molecules diminishes the imaging sensitivity and specificity. We report a background-free PA imaging technique based on the active modulation of PA signals via magnetic alignment of Fe3O4@Au hybrid nanorods. Switching the field direction creates enhanced and deactivated PA imaging modalities, enabling a simple pixel subtraction to effectively minimize background noises. Under an alternating magnetic field, the nanorods exhibit PA signals of coherently periodic changes that can be converted into a sharp peak in a frequency domain via the fast Fourier transform. Automatic pixel-wise screening of nanorod signals performed using a computational algorithm across a time-sequence set of PA images regenerates a background-free PA image with significantly improved contrast, specificity, and fidelity.
Collapse
Affiliation(s)
- Zhiwei Li
- Department of Chemistry, University of California, Riverside, California 92521, United States
| | - Zhouqi Meng
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou, Jiangsu 215123, China
| | - Feng Tian
- Department of Chemistry, University of California, Riverside, California 92521, United States
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon 999077, Hong Kong China
| | - Zuyang Ye
- Department of Chemistry, University of California, Riverside, California 92521, United States
| | - Xuanfang Zhou
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou, Jiangsu 215123, China
| | - Xingjian Zhong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon 999077, Hong Kong China
| | - Qian Chen
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou, Jiangsu 215123, China
| | - Mo Yang
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon 999077, Hong Kong China
| | - Zhuang Liu
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou, Jiangsu 215123, China
| | - Yadong Yin
- Department of Chemistry, University of California, Riverside, California 92521, United States
| |
Collapse
|
35
|
Goebel CA, Brown E, Fahlbusch FB, Wagner AL, Buehler A, Raupach T, Hohmann M, Späth M, Burton N, Woelfle J, Schmidt M, Hartner A, Regensburger AP, Knieling F. High-resolution label-free mapping of murine kidney vasculature by raster-scanning optoacoustic mesoscopy: an ex vivo study. Mol Cell Pediatr 2022; 9:13. [PMID: 35788444 PMCID: PMC9253231 DOI: 10.1186/s40348-022-00144-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 05/06/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Chronic kidney disease (CKD) is a global burden affecting both children and adults. Novel imaging modalities hold great promise to visualize and quantify structural, functional, and molecular organ damage. The aim of the study was to visualize and quantify murine renal vasculature using label-free raster scanning optoacoustic mesoscopy (RSOM) in explanted organs from mice with renal injury. MATERIAL AND METHODS For the experiments, freshly bisected kidneys of alpha 8 integrin knock-out (KO) and wildtype mice (WT) were used. A total of n=7 female (n=4 KO, n=3 WT) and n=6 male animals (n=2 KO, n=4 WT) aged 6 weeks were examined with RSOM optoacoustic imaging systems (RSOM Explorer P50 at SWL 532nm and/or ms-P50 imaging system at 532 nm, 555 nm, 579 nm, and 606 nm). Images were reconstructed using a dedicated software, analyzed for size and vascular area and compared to standard histologic sections. RESULTS RSOM enabled mapping of murine kidney size and vascular area, revealing differences between kidney sizes of male (m) and female (f) mice (merged frequencies (MF) f vs. m: 52.42±6.24 mm2 vs. 69.18±15.96 mm2, p=0.0156) and absolute vascular area (MF f vs. m: 35.67±4.22 mm2 vs. 49.07±13.48 mm2, p=0.0036). Without respect to sex, the absolute kidney area was found to be smaller in knock-out (KO) than in wildtype (WT) mice (WT vs. KO: MF: p=0.0255) and showed a similar trend for the relative vessel area (WT vs. KO: MF p=0.0031). Also the absolute vessel areas of KO compared to WT were found significantly different (MF p=0.0089). A significant decrease in absolute vessel area was found in KO compared to WT male mice (MF WT vs. KO: 54.37±9.35 mm2 vs. 34.93±13.82 mm2, p=0.0232). In addition, multispectral RSOM allowed visualization of oxygenated and deoxygenated parenchymal regions by spectral unmixing. CONCLUSION This study demonstrates the capability of RSOM for label-free visualization of differences in vascular morphology in ex vivo murine renal tissue at high resolution. Due to its scalability optoacoustic imaging provides an emerging modality with potential for further preclinical and clinical imaging applications.
Collapse
Affiliation(s)
- Colin A Goebel
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
| | - Emma Brown
- Department of Physics, University of Cambridge, Cambridge, UK.,Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK.,Washington University School of Medicine, St. Louis, USA
| | - Fabian B Fahlbusch
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
| | - Alexandra L Wagner
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
| | - Adrian Buehler
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
| | - Thomas Raupach
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
| | - Martin Hohmann
- Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Erlangen Graduate School in Advanced Optical Technologies, 91052, Erlangen, Germany
| | - Moritz Späth
- Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Erlangen Graduate School in Advanced Optical Technologies, 91052, Erlangen, Germany
| | | | - Joachim Woelfle
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
| | - Michael Schmidt
- Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Erlangen Graduate School in Advanced Optical Technologies, 91052, Erlangen, Germany
| | - Andrea Hartner
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
| | - Adrian P Regensburger
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
| | - Ferdinand Knieling
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany.
| |
Collapse
|
36
|
Hui X, Malik MOA, Pramanik M. Looking deep inside tissue with photoacoustic molecular probes: a review. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:070901. [PMID: 36451698 PMCID: PMC9307281 DOI: 10.1117/1.jbo.27.7.070901] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 07/01/2022] [Indexed: 05/19/2023]
Abstract
Significance Deep tissue noninvasive high-resolution imaging with light is challenging due to the high degree of light absorption and scattering in biological tissue. Photoacoustic imaging (PAI) can overcome some of the challenges of pure optical or ultrasound imaging to provide high-resolution deep tissue imaging. However, label-free PAI signals from light absorbing chromophores within the tissue are nonspecific. The use of exogeneous contrast agents (probes) not only enhances the imaging contrast (and imaging depth) but also increases the specificity of PAI by binding only to targeted molecules and often providing signals distinct from the background. Aim We aim to review the current development and future progression of photoacoustic molecular probes/contrast agents. Approach First, PAI and the need for using contrast agents are briefly introduced. Then, the recent development of contrast agents in terms of materials used to construct them is discussed. Then, various probes are discussed based on targeting mechanisms, in vivo molecular imaging applications, multimodal uses, and use in theranostic applications. Results Material combinations are being used to develop highly specific contrast agents. In addition to passive accumulation, probes utilizing activation mechanisms show promise for greater controllability. Several probes also enable concurrent multimodal use with fluorescence, ultrasound, Raman, magnetic resonance imaging, and computed tomography. Finally, targeted probes are also shown to aid localized and molecularly specific photo-induced therapy. Conclusions The development of contrast agents provides a promising prospect for increased contrast, higher imaging depth, and molecularly specific information. Of note are agents that allow for controlled activation, explore other optical windows, and enable multimodal use to overcome some of the shortcomings of label-free PAI.
Collapse
Affiliation(s)
- Xie Hui
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Mohammad O. A. Malik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Manojit Pramanik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| |
Collapse
|
37
|
Brown EL, Lefebvre TL, Sweeney PW, Stolz BJ, Gröhl J, Hacker L, Huang Z, Couturier DL, Harrington HA, Byrne HM, Bohndiek SE. Quantification of vascular networks in photoacoustic mesoscopy. PHOTOACOUSTICS 2022; 26:100357. [PMID: 35574188 PMCID: PMC9095888 DOI: 10.1016/j.pacs.2022.100357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Mesoscopic photoacoustic imaging (PAI) enables non-invasive visualisation of tumour vasculature. The visual or semi-quantitative 2D measurements typically applied to mesoscopic PAI data fail to capture the 3D vessel network complexity and lack robust ground truths for assessment of accuracy. Here, we developed a pipeline for quantifying 3D vascular networks captured using mesoscopic PAI and tested the preservation of blood volume and network structure with topological data analysis. Ground truth data of in silico synthetic vasculatures and a string phantom indicated that learning-based segmentation best preserves vessel diameter and blood volume at depth, while rule-based segmentation with vesselness image filtering accurately preserved network structure in superficial vessels. Segmentation of vessels in breast cancer patient-derived xenografts (PDXs) compared favourably to ex vivo immunohistochemistry. Furthermore, our findings underscore the importance of validating segmentation methods when applying mesoscopic PAI as a tool to evaluate vascular networks in vivo.
Collapse
Affiliation(s)
- Emma L. Brown
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Thierry L. Lefebvre
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Paul W. Sweeney
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Bernadette J. Stolz
- Mathematical Institute, University of Oxford, Woodstock Road, Oxford OX2 6GG, UK
| | - Janek Gröhl
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Lina Hacker
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | - Ziqiang Huang
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| | | | | | - Helen M. Byrne
- Mathematical Institute, University of Oxford, Woodstock Road, Oxford OX2 6GG, UK
| | - Sarah E. Bohndiek
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Robinson Way, Cambridge CB2 0RE, UK
| |
Collapse
|
38
|
Xiao M, Tian F, Liu X, Zhou Q, Pan J, Luo Z, Yang M, Yi C. Virus Detection: From State-of-the-Art Laboratories to Smartphone-Based Point-of-Care Testing. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2105904. [PMID: 35393791 PMCID: PMC9110880 DOI: 10.1002/advs.202105904] [Citation(s) in RCA: 43] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 02/27/2022] [Indexed: 05/07/2023]
Abstract
Infectious virus outbreaks pose a significant challenge to public healthcare systems. Early and accurate virus diagnosis is critical to prevent the spread of the virus, especially when no specific vaccine or effective medicine is available. In clinics, the most commonly used viral detection methods are molecular techniques that involve the measurement of nucleic acids or proteins biomarkers. However, most clinic-based methods require complex infrastructure and expensive equipment, which are not suitable for low-resource settings. Over the past years, smartphone-based point-of-care testing (POCT) has rapidly emerged as a potential alternative to laboratory-based clinical diagnosis. This review summarizes the latest development of virus detection. First, laboratory-based and POCT-based viral diagnostic techniques are compared, both of which rely on immunosensing and nucleic acid detection. Then, various smartphone-based POCT diagnostic techniques, including optical biosensors, electrochemical biosensors, and other types of biosensors are discussed. Moreover, this review covers the development of smartphone-based POCT diagnostics for various viruses including COVID-19, Ebola, influenza, Zika, HIV, et al. Finally, the prospects and challenges of smartphone-based POCT diagnostics are discussed. It is believed that this review will aid researchers better understand the current challenges and prospects for achieving the ultimate goal of containing disease-causing viruses worldwide.
Collapse
Affiliation(s)
- Meng Xiao
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Feng Tian
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHunghomHong Kong999077P. R. China
| | - Xin Liu
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Qiaoqiao Zhou
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Jiangfei Pan
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Zhaofan Luo
- Department of Clinical LaboratoryThe Seventh Affiliated Hospital of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Mo Yang
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHunghomHong Kong999077P. R. China
| | - Changqing Yi
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| |
Collapse
|
39
|
Kim M, Lee KW, Kim K, Gulenko O, Lee C, Keum B, Chun HJ, Choi HS, Kim CU, Yang JM. Intra-instrument channel workable, optical-resolution photoacoustic and ultrasonic mini-probe system for gastrointestinal endoscopy. PHOTOACOUSTICS 2022; 26:100346. [PMID: 35313458 PMCID: PMC8933520 DOI: 10.1016/j.pacs.2022.100346] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 03/08/2022] [Indexed: 05/04/2023]
Abstract
There has been a long-standing expectation that the optical-resolution embodiment of photoacoustic tomography could have a substantial impact on gastrointestinal endoscopy by enabling microscopic visualization of the vasculature based on the endogenous contrast mechanism. Although multiple studies have demonstrated the in vivo imaging capability of a developed imaging device over the last decade, the implementation of such an endoscopic system that can be applied immediately when necessary via the instrument channel of a video endoscope has been a challenge. In this study, we developed a 3.38-mm diameter catheter-based, integrated optical-resolution photoacoustic and ultrasonic mini-probe system and successfully demonstrated its intra-instrument channel workability for the standard 3.7-mm diameter instrument channel of a clinical video endoscope based on a swine model. Through the instrument channel, we acquired the first in vivo dual-mode photoacoustic and ultrasonic endoscopic images from the esophagogastric junction of a swine. Further, in a rat colorectum in vivo imaging experiment, we visualized hierarchically developed mesh-like capillary networks with a hole size as small as ~50 µm, which suggests the potential level of image details that could be photoacoustically provided in clinical settings in the future.
Collapse
Affiliation(s)
- Minjae Kim
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
| | - Kang Won Lee
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul 02841, South Korea
| | - KiSik Kim
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
| | - Oleksandra Gulenko
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
| | - Cheol Lee
- Department of Physics, UNIST, Ulsan 44919, South Korea
| | - Bora Keum
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul 02841, South Korea
| | - Hoon Jai Chun
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul 02841, South Korea
| | - Hyuk Soon Choi
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul 02841, South Korea
- Corresponding authors.
| | - Chae Un Kim
- Department of Physics, UNIST, Ulsan 44919, South Korea
- Corresponding authors.
| | - Joon-Mo Yang
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
- Corresponding authors.
| |
Collapse
|
40
|
Rajendran P, Pramanik M. High frame rate (∼3 Hz) circular photoacoustic tomography using single-element ultrasound transducer aided with deep learning. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:066005. [PMID: 36452448 PMCID: PMC9209813 DOI: 10.1117/1.jbo.27.6.066005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Accepted: 06/01/2022] [Indexed: 05/29/2023]
Abstract
SIGNIFICANCE In circular scanning photoacoustic tomography (PAT), it takes several minutes to generate an image of acceptable quality, especially with a single-element ultrasound transducer (UST). The imaging speed can be enhanced by faster scanning (with high repetition rate light sources) and using multiple-USTs. However, artifacts arising from the sparse signal acquisition and low signal-to-noise ratio at higher scanning speeds limit the imaging speed. Thus, there is a need to improve the imaging speed of the PAT systems without hampering the quality of the PAT image. AIM To improve the frame rate (or imaging speed) of the PAT system by using deep learning (DL). APPROACH For improving the frame rate (or imaging speed) of the PAT system, we propose a novel U-Net-based DL framework to reconstruct PAT images from fast scanning data. RESULTS The efficiency of the network was evaluated on both single- and multiple-UST-based PAT systems. Both phantom and in vivo imaging demonstrate that the network can improve the imaging frame rate by approximately sixfold in single-UST-based PAT systems and by approximately twofold in multi-UST-based PAT systems. CONCLUSIONS We proposed an innovative method to improve the frame rate (or imaging speed) by using DL and with this method, the fastest frame rate of ∼ 3 Hz imaging is achieved without hampering the quality of the reconstructed image.
Collapse
Affiliation(s)
| | - Manojit Pramanik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| |
Collapse
|
41
|
Akhtar R, Masud MM. Dynamic linkages between climatic variables and agriculture production in Malaysia: a generalized method of moments approach. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:41557-41566. [PMID: 35094275 DOI: 10.1007/s11356-021-18210-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 12/14/2021] [Indexed: 05/25/2023]
Abstract
Climate change continues to pose a threat to the agricultural sectors worldwide, jeopardizing food and nutritional security, which is a critical component of the sustainable development agenda. Consequently, this study attempts to examine the impact of climatic variables (CO2 emissions, energy resources, rainfall, temperature, fossil fuel consumption, and humidity) on agricultural production of rice, cereals, vegetables, coffee, and agriculture value added (as a percentage of GDP) in the Malaysian context. To this end, this study applied a generalized method of moments (GMM) estimator on the data obtained from the metrological station Malaysia, Department of Statistics Malaysia and World Development Indicators (WDI) spanning the period 1985-2016. The results revealed that temperature and energy consumption negatively and significantly affect rice and vegetable production, while the negative effect of rainfall, temperature, fossil fuel consumption, and humidity on cereal production is insignificant. The results also confirmed that CO2 emissions have a negative and significant impact on coffee production. Likewise, temperature, energy consumption, and fossil fuel consumption exhibit a negative and significant influence on agriculture value added. These observations evidenced the adverse effect of climate change on various agricultural products in Malaysia. Therefore, in order to ensure robust and sustainable agricultural output in Malaysia, policymakers as well as environmentalists should work together to formulate appropriate adaptation strategies.
Collapse
Affiliation(s)
- Rulia Akhtar
- Ungku Aziz Centre for Development Studies,, Office of Deputy Vice Chancellor (Research & Innovation), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Muhammad Mehedi Masud
- Department of Development Studies, Faculty of Business and Economics, Universiti Malaya, Kuala Lumpur, Malaysia.
- Department of Business Administration, Daffodil International University, Dhaka, Bangladesh.
| |
Collapse
|
42
|
Towards rainbow portable Cytophone with laser diodes for global disease diagnostics. Sci Rep 2022; 12:8671. [PMID: 35606373 PMCID: PMC9126638 DOI: 10.1038/s41598-022-11452-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 04/18/2022] [Indexed: 11/08/2022] Open
Abstract
In vivo, Cytophone has demonstrated the capability for the early diagnosis of cancer, infection, and cardiovascular disorders through photoacoustic detection of circulating disease markers directly in the bloodstream with an unprecedented 1,000-fold improvement in sensitivity. Nevertheless, a Cytophone with higher specificity and portability is urgently needed. Here, we introduce a novel Cytophone platform that integrates a miniature multispectral laser diode array, time-color coding, and high-speed time-resolved signal processing. Using two-color (808 nm/915 nm) laser diodes, we demonstrated spectral identification of white and red clots, melanoma cells, and hemozoin in malaria-infected erythrocytes against a blood background and artifacts. Data from a Plasmodium yoelii murine model and cultured human P. falciparum were verified in vitro with confocal photothermal and fluorescent microscopy. With these techniques, we detected infected cells within 4 h after invasion, which makes hemozoin promising as a spectrally selective marker at the earliest stages of malaria progression. Along with the findings from our previous application of Cytophone with conventional lasers for the diagnosis of melanoma, bacteremia, sickle anemia, thrombosis, stroke, and abnormal hemoglobin forms, this current finding suggests the potential for the development of a portable rainbow Cytophone with multispectral laser diodes for the identification of these and other diseases.
Collapse
|
43
|
Deep-Learning-Based Algorithm for the Removal of Electromagnetic Interference Noise in Photoacoustic Endoscopic Image Processing. SENSORS 2022; 22:s22103961. [PMID: 35632370 PMCID: PMC9147354 DOI: 10.3390/s22103961] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 05/18/2022] [Accepted: 05/21/2022] [Indexed: 12/10/2022]
Abstract
Despite all the expectations for photoacoustic endoscopy (PAE), there are still several technical issues that must be resolved before the technique can be successfully translated into clinics. Among these, electromagnetic interference (EMI) noise, in addition to the limited signal-to-noise ratio (SNR), have hindered the rapid development of related technologies. Unlike endoscopic ultrasound, in which the SNR can be increased by simply applying a higher pulsing voltage, there is a fundamental limitation in leveraging the SNR of PAE signals because they are mostly determined by the optical pulse energy applied, which must be within the safety limits. Moreover, a typical PAE hardware situation requires a wide separation between the ultrasonic sensor and the amplifier, meaning that it is not easy to build an ideal PAE system that would be unaffected by EMI noise. With the intention of expediting the progress of related research, in this study, we investigated the feasibility of deep-learning-based EMI noise removal involved in PAE image processing. In particular, we selected four fully convolutional neural network architectures, U-Net, Segnet, FCN-16s, and FCN-8s, and observed that a modified U-Net architecture outperformed the other architectures in the EMI noise removal. Classical filter methods were also compared to confirm the superiority of the deep-learning-based approach. Still, it was by the U-Net architecture that we were able to successfully produce a denoised 3D vasculature map that could even depict the mesh-like capillary networks distributed in the wall of a rat colorectum. As the development of a low-cost laser diode or LED-based photoacoustic tomography (PAT) system is now emerging as one of the important topics in PAT, we expect that the presented AI strategy for the removal of EMI noise could be broadly applicable to many areas of PAT, in which the ability to apply a hardware-based prevention method is limited and thus EMI noise appears more prominently due to poor SNR.
Collapse
|
44
|
Fast raster-scan optoacoustic mesoscopy enables assessment of human melanoma microvasculature in vivo. Nat Commun 2022; 13:2803. [PMID: 35589757 PMCID: PMC9120110 DOI: 10.1038/s41467-022-30471-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 05/03/2022] [Indexed: 12/23/2022] Open
Abstract
Melanoma is associated with angiogenesis and vascular changes that may extend through the entire skin depth. Three-dimensional imaging of vascular characteristics in skin lesions could therefore allow diagnostic insights not available by conventional visual inspection. Raster-scan optoacoustic mesoscopy (RSOM) images microvasculature through the entire skin depth with resolutions of tens of micrometers; however, current RSOM implementations are too slow to overcome the strong breathing motions on the upper torso where melanoma lesions commonly occur. To enable high-resolution imaging of melanoma vasculature in humans, we accelerate RSOM scanning using an illumination scheme that is coaxial with a high-sensitivity ultrasound detector path, yielding 15 s single-breath-hold scans that minimize motion artifacts. We apply this Fast RSOM to image 10 melanomas and 10 benign nevi in vivo, showing marked differences between malignant and benign lesions, supporting the possibility to use biomarkers extracted from RSOM imaging of vasculature for lesion characterization to improve diagnostics. Raster-Scanning-Optoacoustic Mesoscopy can be used to image the vasculature in skin cancer lesions but is limited by a long exposure time. Here; the authors increase the speed of the imaging using co-axial illumination and a high-sensitivity ultrasound detector path.
Collapse
|
45
|
Hindelang B, Nau T, Englert L, Berezhnoi A, Lauffer F, Darsow U, Biedermann T, Eyerich K, Aguirre J, Ntziachristos V. Enabling precision monitoring of psoriasis treatment by optoacoustic mesoscopy. Sci Transl Med 2022; 14:eabm8059. [PMID: 35544596 DOI: 10.1126/scitranslmed.abm8059] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Psoriasis is a widespread inflammatory skin disease affecting about 2% of the general population. Recently, treatments that specifically target key proinflammatory cytokines driving the disease have been developed to complement conventional therapies with unspecific antiproliferative or anti-inflammatory effects. Efficient monitoring of treatment efficacy in the context of precision medicine and the assessment of new therapeutics require accurate noninvasive readouts of disease progression. However, characterization of psoriasis treatment remains subjective based on visual and palpatory clinical assessment of features observed on the skin surface. We hypothesized that optoacoustic (photoacoustic) mesoscopy could offer label-free assessment of inflammation biomarkers, extracted from three-dimensional (3D) high-resolution images of the human skin, not attainable by other noninvasive methods. We developed a second-generation ultra-broadband optoacoustic mesoscopy system, featuring sub-10-μm resolution and advanced motion correction technology, and performed 80 longitudinal measurements of 20 psoriatic skin plaques in humans under conventional inpatient treatment or receiving biologics with concomitant topical corticosteroid treatment. Optoacoustic image analysis revealed inflammatory and morphological skin features that indicated treatment efficacy with sensitivity, accuracy, and precision that was not possible using clinical metrics. We identify 3D imaging biomarkers that reveal responses to treatment and offer the potential to facilitate disease and treatment characterization. Our findings suggest that optoacoustic mesoscopy may offer a method of choice for yielding both qualitative and quantitative evaluations of skin treatments that are inaccessible by other methods, potentially enabling optimized therapies and precision medicine in dermatology.
Collapse
Affiliation(s)
- Benedikt Hindelang
- Department of Dermatology and Allergy, Technical University of Munich, 81675 Munich, Germany.,Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764, Neuherberg, Germany
| | - Teresa Nau
- Department of Dermatology and Allergy, Technical University of Munich, 81675 Munich, Germany.,Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764, Neuherberg, Germany
| | - Ludwig Englert
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764, Neuherberg, Germany
| | - Andrei Berezhnoi
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764, Neuherberg, Germany
| | - Felix Lauffer
- Department of Dermatology and Allergy, Technical University of Munich, 81675 Munich, Germany
| | - Ulf Darsow
- Department of Dermatology and Allergy, Technical University of Munich, 81675 Munich, Germany
| | - Tilo Biedermann
- Department of Dermatology and Allergy, Technical University of Munich, 81675 Munich, Germany
| | - Kilian Eyerich
- Department of Dermatology and Allergy, Technical University of Munich, 81675 Munich, Germany
| | - Juan Aguirre
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764, Neuherberg, Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging, Technical University of Munich, 81675 Munich, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum Munich, 85764, Neuherberg, Germany.,Munich Institute of Robotics and Machine Intelligence (MIRMI), Technical University of Munich, 81675 Munich, Germany
| |
Collapse
|
46
|
Voskuil FJ, Vonk J, van der Vegt B, Kruijff S, Ntziachristos V, van der Zaag PJ, Witjes MJH, van Dam GM. Intraoperative imaging in pathology-assisted surgery. Nat Biomed Eng 2022; 6:503-514. [PMID: 34750537 DOI: 10.1038/s41551-021-00808-8] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 06/17/2021] [Indexed: 12/12/2022]
Abstract
The pathological assessment of surgical specimens during surgery can reduce the incidence of positive resection margins, which otherwise can result in additional surgeries or aggressive therapeutic regimens. To improve patient outcomes, intraoperative spectroscopic, fluorescence-based, structural, optoacoustic and radiological imaging techniques are being tested on freshly excised tissue. The specific clinical setting and tumour type largely determine whether endogenous or exogenous contrast is to be detected and whether the tumour specificity of the detected biomarker, image resolution, image-acquisition times or penetration depth are to be prioritized. In this Perspective, we describe current clinical standards for intraoperative tissue analysis and discuss how intraoperative imaging is being implemented. We also discuss potential implementations of intraoperative pathology-assisted surgery for clinical decision-making.
Collapse
Affiliation(s)
- Floris J Voskuil
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Department of Pathology and Medical Biology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Jasper Vonk
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Bert van der Vegt
- Department of Pathology and Medical Biology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Schelto Kruijff
- Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Vasilis Ntziachristos
- Chair for Biological Imaging, Center for Translational Cancer Research, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
| | - Pieter J van der Zaag
- Phillips Research Laboratories, Eindhoven, The Netherlands.,Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Molecular Biophysics, Zernike Institute, University of Groningen, Groningen, The Netherlands
| | - Max J H Witjes
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Gooitzen M van Dam
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands. .,AxelaRx/TRACER BV, Groningen, The Netherlands.
| |
Collapse
|
47
|
Silicon-photonics acoustic detector for optoacoustic micro-tomography. Nat Commun 2022; 13:1488. [PMID: 35304481 PMCID: PMC8933411 DOI: 10.1038/s41467-022-29179-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 02/28/2022] [Indexed: 11/08/2022] Open
Abstract
Medical ultrasound and optoacoustic (photoacoustic) imaging commonly rely on the concepts of beam-forming and tomography for image formation, enabled by piezoelectric array transducers whose element size is comparable to the desired resolution. However, the tomographic measurement of acoustic signals becomes increasingly impractical for resolutions beyond 100 µm due to the reduced efficiency of piezoelectric elements upon miniaturization. For higher resolutions, a microscopy approach is preferred, in which a single focused ultrasound transducer images the object point-by-point, but the bulky apparatus and long acquisition time of this approach limit clinical applications. In this work, we demonstrate a miniaturized acoustic detector capable of tomographic imaging with spread functions whose width is below 20 µm. The detector is based on an optical resonator fabricated in a silicon-photonics platform coated by a sensitivity-enhancing elastomer, which also effectively eliminates the parasitic effect of surface acoustic waves. The detector is demonstrated in vivo in high-resolution optoacoustic tomography.
Collapse
|
48
|
Lefebvre TL, Brown E, Hacker L, Else T, Oraiopoulou ME, Tomaszewski MR, Jena R, Bohndiek SE. The Potential of Photoacoustic Imaging in Radiation Oncology. Front Oncol 2022; 12:803777. [PMID: 35311156 PMCID: PMC8928467 DOI: 10.3389/fonc.2022.803777] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 02/07/2022] [Indexed: 12/16/2022] Open
Abstract
Radiotherapy is recognized globally as a mainstay of treatment in most solid tumors and is essential in both curative and palliative settings. Ionizing radiation is frequently combined with surgery, either preoperatively or postoperatively, and with systemic chemotherapy. Recent advances in imaging have enabled precise targeting of solid lesions yet substantial intratumoral heterogeneity means that treatment planning and monitoring remains a clinical challenge as therapy response can take weeks to manifest on conventional imaging and early indications of progression can be misleading. Photoacoustic imaging (PAI) is an emerging modality for molecular imaging of cancer, enabling non-invasive assessment of endogenous tissue chromophores with optical contrast at unprecedented spatio-temporal resolution. Preclinical studies in mouse models have shown that PAI could be used to assess response to radiotherapy and chemoradiotherapy based on changes in the tumor vascular architecture and blood oxygen saturation, which are closely linked to tumor hypoxia. Given the strong relationship between hypoxia and radio-resistance, PAI assessment of the tumor microenvironment has the potential to be applied longitudinally during radiotherapy to detect resistance at much earlier time-points than currently achieved by size measurements and tailor treatments based on tumor oxygen availability and vascular heterogeneity. Here, we review the current state-of-the-art in PAI in the context of radiotherapy research. Based on these studies, we identify promising applications of PAI in radiation oncology and discuss the future potential and outstanding challenges in the development of translational PAI biomarkers of early response to radiotherapy.
Collapse
Affiliation(s)
- Thierry L. Lefebvre
- Department of Physics, University of Cambridge, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, United Kingdom
| | - Emma Brown
- Department of Physics, University of Cambridge, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, United Kingdom
| | - Lina Hacker
- Department of Physics, University of Cambridge, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, United Kingdom
| | - Thomas Else
- Department of Physics, University of Cambridge, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, United Kingdom
| | - Mariam-Eleni Oraiopoulou
- Department of Physics, University of Cambridge, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, United Kingdom
| | - Michal R. Tomaszewski
- Department of Cancer Physiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, United States
| | - Rajesh Jena
- Department of Oncology, University of Cambridge, Cambridge, United Kingdom
| | - Sarah E. Bohndiek
- Department of Physics, University of Cambridge, Cambridge, United Kingdom
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
49
|
Asadollahi A, Latifi H, Zeynali S, Pramanik M, Qazvini H. Accuracy of peak-power compensation in fiber-guided and free-space acoustic-resolution photoacoustic microscopy. BIOMEDICAL OPTICS EXPRESS 2022; 13:1774-1783. [PMID: 35414989 PMCID: PMC8973166 DOI: 10.1364/boe.453475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 02/09/2022] [Accepted: 02/17/2022] [Indexed: 06/14/2023]
Abstract
Acoustic resolution photoacoustic microscopy (AR-PAM) has gained much attention in the past two decades due to its high contrast, scalable resolution, and relatively higher imaging depth. Multimode optical fibers (MMF) are extensively used to transfer light to AR-PAM imaging scan-head from the laser source. Typically, peak-power-compensation (PPC) is used to reduce the effect of pulse-to-pulse peak-power variation in generated photoacoustic (PA) signals. In MMF, the output intensity profile fluctuates due to the coherent nature of light and mode exchange caused by variations in the bending of the fibers during scanning. Therefore, using a photodiode (PD) to capture a portion of the total power of pulses as a measure of illuminated light on the sample may not be appropriate for accurate PPC. In this study, we have investigated the accuracy of PPC in fiber-guided and free-space AR-PAM systems. Experiments were conducted in the transparent and highly scattering medium. Based on obtained results for the MMF-based system, to apply PPC to the generated PA signals, tightly focused light confocal with the acoustic focus in a transparent medium must be used. In the clear medium and highly focused illumination, enhancement of about 45% was obtained in the homogeneity of an optically homogeneous sample image. In addition, it is shown that, as an alternative, free-space propagation of the laser pulses results in more accurate PPC in both transparent and highly scattering mediums. In free-space light transmission, enhancement of 25-75% was obtained in the homogeneity of the optically homogeneous sample image.
Collapse
Affiliation(s)
- Amir Asadollahi
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran
| | - Hamid Latifi
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran
- Department of Physics, Shahid Beheshti University, Tehran, Iran
| | - Shahriar Zeynali
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
| | - Hamed Qazvini
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, Iran
| |
Collapse
|
50
|
Mantri Y, Jokerst JV. Impact of skin tone on photoacoustic oximetry and tools to minimize bias. BIOMEDICAL OPTICS EXPRESS 2022; 13:875-887. [PMID: 35284157 PMCID: PMC8884230 DOI: 10.1364/boe.450224] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 01/13/2022] [Accepted: 01/14/2022] [Indexed: 05/02/2023]
Abstract
The major optical absorbers in tissue are melanin and oxy/deoxy-hemoglobin, but the impact of skin tone and pigmentation on biomedical optics is still not completely understood or adequately addressed. Melanin largely governs skin tone with higher melanin concentration in subjects with darker skin tones. Recently, there has been extensive debate on the bias of pulse oximeters when used with darker subjects. Photoacoustic (PA) imaging can measure oxygen saturation similarly as pulse oximeters and could have value in studying this bias. More importantly, it can deconvolute the signal from the skin and underlying tissue. Here, we studied the impact of skin tone on PA signal generation, depth penetration, and oximetry. Our results show that subjects with darker skin tones exhibit significantly higher PA signal at the skin surface, reduced penetration depth, and lower oxygen saturation compared to subjects with lighter skin tones. We then suggest a simple way to compensate for these signal differences.
Collapse
Affiliation(s)
- Yash Mantri
- Department of Bioengineering, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| | - Jesse V. Jokerst
- Department of Nanoengineering, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
- Material Science Department, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
- Department of Radiology, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92093, USA
| |
Collapse
|