1
|
Li W, Zhang Y, Xie Q, Qi X, Yao L, Ning X, Qian Z. Dual-modal in vivo assessment for electrophysical and hemodynamic characteristics of cerebral edema induced by lipopolysaccharide. Biomed Eng Online 2022; 21:79. [DOI: 10.1186/s12938-022-01047-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 10/30/2022] [Indexed: 11/23/2022] Open
Abstract
AbstractThe pathological features of cerebral edema are complicated. The intracranial pressure (ICP) is regarded as the most important indicator for monitoring cerebral edema. Recently, multi-parameter has been used to explore the types and pathogenesis of cerebral edema and design effective treatment strategies. This research focused on investigating the characteristic of the cerebral edema induced by lipopolysaccharide (LPS) in rats by using simultaneous electrophysical and hemodynamic parameters. The results showed that neurophysiologic parameters (firing rate (FR) and the power spectrum of local field potential (LFP power)) and hemodynamic parameters (relative concentration of oxygenated hemoglobin (ΔCHbO2), relative concentration of deoxyhemoglobin ΔCHbR) and relative cerebral blood flow (rCBF)) were linearly correlated, and the Pearson’s correlation coefficient was changed by pathological progression of cerebral edema induced by LPS. Furtherly, the treatment after two agents were observed successfully through these multi-parameters. Our findings revealed the relationship between neural activity and hemodynamic response during the progression of cerebral edema and provided a multi-parameter solution for cerebral edema functional monitoring and anti-edema drug efficacy evaluation.
Collapse
|
2
|
Su X, Zhou M, Di L, Chen J, Zhai Z, Liang J, Li L, Li H, Chai X. The Visual Cortical Responses to Sinusoidal Transcorneal Electrical Stimulation. Brain Res 2022; 1785:147875. [PMID: 35271821 DOI: 10.1016/j.brainres.2022.147875] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 03/04/2022] [Accepted: 03/05/2022] [Indexed: 11/25/2022]
Abstract
Retinal stimulation has become a widely utilized approach to restore visual function for individuals with retinal degenerative diseases. Although the rectangular electrical pulse is the primary stimulus waveform used in retinal neuromodulation, it remains unclear whether alternate waveforms may be more effective. Here, we used the optical intrinsic signal imaging system to assess the responses of cats' visual cortex to sinusoidal electrical stimulation through contact lens electrode, analyzing the response to various stimulus parameters (frequency, intensity, pulse width). A comparison between sinusoidal and rectangular stimulus waveform was also investigated. The results indicated that the optimal stimulation frequency for sinusoidal electrical stimulation was approximately 20 Hz, supporting the hypothesis that low-frequency electrostimulation induces more responsiveness in retinal neurons than high-frequency electrostimulation in case of sinusoidal stimulation. We also demonstrated that for low-frequency retinal neuromodulation, sinusoidal pulses are more effective than rectangular ones. In addition, we found that compared to current intensity, the effect of the sinusoidal pulse width on cortical responses was more prominent. These results suggested that sinusoidal electrical stimulation may provide a promising strategy for improved retinal neuromodulation in clinical settings.
Collapse
Affiliation(s)
- Xiaofan Su
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Meixuan Zhou
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Liqing Di
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, China
| | - Jianpin Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhenzhen Zhai
- The Network & Information Center, Shanghai Jiao Tong University, Shanghai, China
| | - Junling Liang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Liming Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Heng Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Xinyu Chai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
3
|
Optimizing intact skull intrinsic signal imaging for subsequent targeted electrophysiology across mouse visual cortex. Sci Rep 2022; 12:2063. [PMID: 35136111 PMCID: PMC8826313 DOI: 10.1038/s41598-022-05932-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Accepted: 01/18/2022] [Indexed: 12/16/2022] Open
Abstract
Understanding brain function requires repeatable measurements of neural activity across multiple scales and multiple brain areas. In mice, large scale cortical neural activity evokes hemodynamic changes readily observable with intrinsic signal imaging (ISI). Pairing ISI with visual stimulation allows identification of primary visual cortex (V1) and higher visual areas (HVAs), typically through cranial windows that thin or remove the skull. These procedures can diminish long-term mechanical and physiological stability required for delicate electrophysiological measurements made weeks to months after imaging (e.g., in subjects undergoing behavioral training). Here, we optimized and directly validated an intact skull ISI system in mice. We first assessed how imaging quality and duration affect reliability of retinotopic maps in V1 and HVAs. We then verified ISI map retinotopy in V1 and HVAs with targeted, multi-site electrophysiology several weeks after imaging. Reliable ISI maps of V1 and multiple HVAs emerged with ~ 60 trials of imaging (65 ± 6 min), and these showed strong correlation to local field potential (LFP) retinotopy in superficial cortical layers (r2 = 0.74–0.82). This system is thus well-suited for targeted, multi-area electrophysiology weeks to months after imaging. We provide detailed instructions and code for other researchers to implement this system.
Collapse
|
4
|
Guinto MC, Haruta M, Kurauchi Y, Saigo T, Kurasawa K, Ryu S, Ohta Y, Kawahara M, Takehara H, Tashiro H, Sasagawa K, Katsuki H, Ohta J. Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:026501. [PMID: 35166087 PMCID: PMC8843356 DOI: 10.1117/1.jbo.27.2.026501] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 01/24/2022] [Indexed: 06/14/2023]
Abstract
SIGNIFICANCE Intrinsic optical signals (IOS) generated in the cortical tissue as a result of various interacting metabolic processes are used extensively to elucidate the underlying mechanisms that govern neurovascular coupling. However, current IOS measurements still often rely on bulky, tabletop imaging systems, and there remains a dearth of studies in freely moving subjects. Lightweight, miniature head-mounted imaging devices provide unique opportunities for investigating cortical dynamics in small animals under a variety of naturalistic behavioral settings. AIM The aim of this work was to monitor IOS in the somatosensory cortex of wild-type mice by developing a lightweight, biocompatible imaging device that readily lends itself to animal experiments in freely moving conditions. APPROACH Herein we describe a method for realizing long-term IOS imaging in mice using a 0.54-g, compact, CMOS-based, head-mounted imager. The two-part module, consisting of a tethered sensor plate and a base plate, allows facile assembly prior to imaging sessions and disassembly when the sensor is not in use. LEDs integrated into the device were chosen to illuminate the cortical mantle at two different wavelengths in the visible regime (λcenter: 535 and 625 nm) for monitoring volume- and oxygenation state-dependent changes in the IOS, respectively. To test whether the system can detect robust cortical responses, we recorded sensory-evoked IOS from mechanical stimulation of the hindlimbs (HL) of anesthetized mice in both acute and long-term implantation conditions. RESULTS Cortical IOS recordings in the primary somatosensory cortex hindlimb receptive field (S1HL) of anesthetized mice under green and red LED illumination revealed robust, multiphasic profiles that were time-locked to the mechanical stimulation of the contralateral plantar hindpaw. Similar intrinsic signal profiles observed in S1HL at 40 days postimplantation demonstrated the viability of the approach for long-term imaging. Immunohistochemical analysis showed that the brain tissue did not exhibit appreciable immune response due to the device implantation and operation. A proof-of-principle imaging session in a freely behaving mouse showed minimal locomotor impediment for the animal and also enabled estimation of blood flow speed. CONCLUSIONS We demonstrate the utility of a miniature cortical imaging device for monitoring IOS and related hemodynamic processes in both anesthetized and freely moving mice, cueing potential for applications to some neuroscientific studies of sensation and naturalistic behavior.
Collapse
Affiliation(s)
- Mark Christian Guinto
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| | - Makito Haruta
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| | - Yuki Kurauchi
- Kumamoto University, Graduate School of Pharmaceutical Sciences, Department of Chemico-Pharmacological Sciences, Kumamoto, Japan
| | - Taisuke Saigo
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| | - Kazuki Kurasawa
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| | - Sumika Ryu
- Kumamoto University, Graduate School of Pharmaceutical Sciences, Department of Chemico-Pharmacological Sciences, Kumamoto, Japan
| | - Yasumi Ohta
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| | - Mamiko Kawahara
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| | - Hironari Takehara
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| | - Hiroyuki Tashiro
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
- Kyushu University, Division of Medical Technology, Department of Health Sciences, Faculty of Medical Sciences, Fukuoka, Japan
| | - Kiyotaka Sasagawa
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| | - Hiroshi Katsuki
- Kumamoto University, Graduate School of Pharmaceutical Sciences, Department of Chemico-Pharmacological Sciences, Kumamoto, Japan
| | - Jun Ohta
- Nara Institute of Science and Technology, Graduate School of Science and Technology, Division of Materials Science, Ikoma, Japan
| |
Collapse
|