Abdalqader ON, Hjouj M, Aljamal M, Hjouj F, Abuzaid M, Mousa M. Reduction of metal artefacts from bilateral hip prostheses during lower extremity computed tomography angiography: an experimental phantom study. J Med Radiat Sci 2024. [PMID: 38941235 DOI: 10.1002/jmrs.797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 05/01/2024] [Indexed: 06/30/2024] Open
Abstract
INTRODUCTION Image quality reduction due to metallic artefacts is a significant challenge during vascular computed tomography (CT) imaging of the lower extremities in patients with hip prostheses. This study aims to analyse various reconstruction algorithms' ability to reduce metal artefacts due to two types of hip prostheses during lower extremity CT angiography examinations. METHODS A pelvis phantom was fabricated with the insertion of a tube filled with contrast media to simulate the femoral artery, and the phantom was then CT scanned with and without hip prostheses. Multimodal images were acquired using different kilovoltage peak (kVp) settings and reconstructed with different algorithms, such as filtered back projection (FBP), iterative reconstruction (iDose4), iterative model-based reconstruction (IMR) and orthopaedic metal artefact reduction (O-MAR). Image quality was assessed based on image noise, signal-to-noise ratio (SNR) and Hounsfield unit (HU) deviation. RESULTS The IMR approach significantly improved image quality compared to iDose4 and FBP. For the vascular region, O-MAR improves SNR by 5 ± 1, 23 ± 5 and 42 ± 9 for FBP, iDose4 and IMR respectively, and improves HU precision towards the baseline values by 49% and 83% for FBP and IMR, respectively. The noise reduction was 71% and 89% for FBP and IMR, and 57% for iDose4. O-MAR greatly enhances SNR corrections among the most severe artefacts, with 29 ± 1 and 43 ± 4 for FBP and IMR, compared to iDose4 by 37 ± 7. CONCLUSION IMR combined with O-MAR could improve the CT angiography of the lower extremities of patients with a hip prosthesis.
Collapse
Affiliation(s)
- Omarah N Abdalqader
- Department of Medical Imaging, Faculty of Health Professions, Al-Quds University, Jerusalem, Palestine
| | - Mohammad Hjouj
- Department of Medical Imaging, Faculty of Health Professions, Al-Quds University, Jerusalem, Palestine
| | - Mohammad Aljamal
- Department of Medical Imaging, Faculty of Allied Medical Sciences, Arab American University, Jenin, Palestine
| | - Fawaz Hjouj
- Department of Mathematics, Khalifa University, Abu Dhabi, UAE
| | - Mohamed Abuzaid
- Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah, UAE
| | - Mahmoud Mousa
- Department of Radiology, Turkish Friendship Hospital, Gaza Strip, Palestine
| |
Collapse
|
2
|
Tore D, Faletti R, Palmisano A, Salto S, Rocco K, Santonocito A, Gaetani C, Biondo A, Bozzo E, Giorgino F, Landolfi I, Menchini F, Esposito A, Fonio P, Gatti M. Cardiac computed tomography with late contrast enhancement: A review. Heliyon 2024; 10:e32436. [PMID: 38933964 PMCID: PMC11200357 DOI: 10.1016/j.heliyon.2024.e32436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 05/19/2024] [Accepted: 06/04/2024] [Indexed: 06/28/2024] Open
Abstract
Cardiac computed tomography (CCT) has assumed an increasingly significant role in the evaluation of coronary artery disease (CAD) during the past few decades, whereas cardiovascular magnetic resonance (CMR) remains the gold standard for myocardial tissue characterization. The discovery of late myocardial enhancement following intravenous contrast administration dates back to the 1970s with ex-vivo CT animal investigations; nevertheless, the clinical application of this phenomenon for cardiac tissue characterization became prevalent for CMR imaging far earlier than for CCT imaging. Recently the technical advances in CT scanners have made it possible to take advantage of late contrast enhancement (LCE) for tissue characterization in CCT exams. Moreover, the introduction of extracellular volume calculation (ECV) on cardiac CT images combined with the possibility of evaluating cardiac function in the same exam is making CCT imaging a multiparametric technique more and more similar to CMR. The aim of our review is to provide a comprehensive overview on the role of CCT with LCE in the evaluation of a wide range of cardiac conditions.
Collapse
Affiliation(s)
- Davide Tore
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Riccardo Faletti
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Anna Palmisano
- Clinical and Experimental Radiology Unit, Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Sara Salto
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Katia Rocco
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Ambra Santonocito
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Clara Gaetani
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Andrea Biondo
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Elena Bozzo
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Fabio Giorgino
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Ilenia Landolfi
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Francesca Menchini
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Antonio Esposito
- Clinical and Experimental Radiology Unit, Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Paolo Fonio
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| | - Marco Gatti
- Radiology Unit, Department of Surgical Sciences, AOU Città Della Salute e Della Scienza di Torino, University of Turin, Turin, Italy
| |
Collapse
|
3
|
Tingsgaard JK, Sørensen MH, Bojer AS, Anderson RH, Broadbent DA, Plein S, Gaede P, Madsen PL. Myocardial Blood Flow Determination From Contrast-Free Magnetic Resonance Imaging Quantification of Coronary Sinus Flow. J Magn Reson Imaging 2024; 59:1258-1266. [PMID: 37491887 DOI: 10.1002/jmri.28919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 07/09/2023] [Accepted: 07/10/2023] [Indexed: 07/27/2023] Open
Abstract
BACKGROUND Determination of myocardial blood flow (MBF) with MRI is usually performed with dynamic contrast enhanced imaging (MBFDCE ). MBF can also be determined from coronary sinus blood flow (MBFCS ), which has the advantage of being a noncontrast technique. However, comparative studies of MBFDCE and MBFCS in large cohorts are lacking. PURPOSE To compare MBFCS and MBFDCE in a large cohort. STUDY TYPE Prospective, sequence-comparison study. POPULATION 147 patients with type 2 diabetes mellitus (age: 56+/-12 years; 106 male; diabetes duration: 12.9+/-8.1 years), and 25 age-matched controls. FIELD STRENGTH/SEQUENCES 1.5 Tesla scanner. Saturation recovery sequence for MBFDCE vs. phase-contrast gradient-echo pulse sequence (free-breathing) for MBFCS . ASSESSMENT MBFDCE and MBFCS were determined at rest and during coronary dilatation achieved by administration of adenosine at 140 μg/kg/min. Myocardial perfusion reserve (MPR) was calculated as the stress/rest ratio of MBF values. Coronary sinus flow was determined twice in the same imaging session for repeatability assessment. STATISTICAL TESTS Agreement between MBFDCE and MBFCS was assessed with Bland and Altman's technique. Repeatability was determined from single-rater random intraclass and repeatability coefficients. RESULTS Rest and stress flows, including both MBFDCE and MBFCS values, ranged from 33 to 146 mL/min/100 g and 92 to 501 mL/min/100 g, respectively. Intraclass and repeatability coefficients for MBFCS were 0.95 (CI 0.90; 0.95) and 5 mL/min/100 g. In Bland-Altman analysis, mean bias at rest was -1.1 mL/min/100 g (CI -3.1; 0.9) with limits of agreement of -27 and 24.8 mL/min/100 g. Mean bias at stress was 6.3 mL/min/100 g (CI -1.1; 14.1) with limits of agreement of -86.9 and 99.9. Mean bias of MPR was 0.11 (CI: -0.02; 0.23) with limits of agreement of -1.43 and 1.64. CONCLUSION MBF may be determined from coronary sinus blood flow, with acceptable bias, but relatively large limits of agreement, against the reference of MBFDCE . LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
| | | | | | | | - David Andrew Broadbent
- Department of Medical Physics and Engineering, Leeds Teaching Hospitals, Leeds, UK
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Peter Gaede
- Department of Internal Medicine, Slagelse-Naestved Hospital, Denmark
| | - Per Lav Madsen
- Department of Cardiology, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
4
|
Bárdyová Z, Horváthová M, Gomola I, Neuschl V, Šimková J. PRECAUTION IN THE USE OF EFFECTIVE DOSE IN CORONARY CT ANGIOGRAPHY. RADIATION PROTECTION DOSIMETRY 2022; 198:547-553. [PMID: 36005971 DOI: 10.1093/rpd/ncac097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 02/11/2022] [Accepted: 02/22/2022] [Indexed: 06/15/2023]
Abstract
The effective dose is a quantity used in clinical practice for statistical evaluation of the radiation dose of patients undergoing different types of examinations. Coronary computed tomography angiography (CCTA) is a specific examination whose calculated effective dose may be subject to several biases. For this reason, it is important to consider factors (different examination techniques, heart rate and patient habitus) that may influence its resulting value. Another critical factor is the methodological procedure for calculating the effective dose and cardiac-specific coefficient used to estimate effective dose from the dose-length product in computed tomography. Because CCTA is increasingly used in cardiology, it is recommended that the chest coefficient be replaced with a new cardiac coefficient when calculating the effective dose.
Collapse
Affiliation(s)
- Zuzana Bárdyová
- Trnava University in Trnava, Faculty of Health Care and Social Work, Department of Laboratory Medicine, Univerzitné námestie 1, 918 43 Trnava, Slovak Republic
| | - Martina Horváthová
- Trnava University in Trnava, Faculty of Health Care and Social Work, Department of Laboratory Medicine, Univerzitné námestie 1, 918 43 Trnava, Slovak Republic
| | - Igor Gomola
- Slovak Medical University, Faculty of Public Health, Department of Radiation Hygiene, Limbová 12, 833 03 Bratislava, Slovak Republic
| | - Vladimír Neuschl
- MRI s. r. o., Institute of Imaging Diagnostics, Starohájska 2, 917 01 Trnava, Slovak Republic
| | - Jana Šimková
- MRI s. r. o., Institute of Imaging Diagnostics, Starohájska 2, 917 01 Trnava, Slovak Republic
| |
Collapse
|
5
|
Reproducibility and Repeatability of Coronary Computed Tomography Angiography (CCTA) Image Segmentation in Detecting Atherosclerosis: A Radiomics Study. Diagnostics (Basel) 2022; 12:diagnostics12082007. [PMID: 36010355 PMCID: PMC9406887 DOI: 10.3390/diagnostics12082007] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 08/02/2022] [Accepted: 08/05/2022] [Indexed: 11/23/2022] Open
Abstract
Atherosclerosis is known as the leading factor in heart disease with the highest mortality rate among the Malaysian population. Usually, the gold standard for diagnosing atherosclerosis is by using the coronary computed tomography angiography (CCTA) technique to look for plaque within the coronary artery. However, qualitative diagnosis for noncalcified atherosclerosis is vulnerable to false-positive diagnoses, as well as inconsistent reporting between observers. In this study, we assess the reproducibility and repeatability of segmenting atherosclerotic lesions manually and semiautomatically in CCTA images to identify the most appropriate CCTA image segmentation method for radiomics analysis to quantitatively extract the atherosclerotic lesion. Thirty (30) CCTA images were taken retrospectively from the radiology image database of Hospital Canselor Tuanku Muhriz (HCTM), Kuala Lumpur, Malaysia. We extract 11,700 radiomics features which include the first-order, second-order and shape features from 180 times of image segmentation. The interest vessels were segmentized manually and semiautomatically using LIFEx (Version 7.0.15, Institut Curie, Orsay, France) software by two independent radiology experts, focusing on three main coronary blood vessels. As a result, manual segmentation with a soft-tissuewindowing setting yielded higher repeatability as compared to semiautomatic segmentation with a significant intraclass correlation coefficient (intra-CC) 0.961 for thefirst-order and shape features; intra-CC of 0.924 for thesecond-order features with p < 0.001. Meanwhile, the semiautomatic segmentation has higher reproducibility as compared to manual segmentation with significant interclass correlation coefficient (inter-CC) of 0.920 (first-order features) and a good interclass correlation coefficient of 0.839 for the second-order features with p < 0.001. The first-order, shape order and second-order features for both manual and semiautomatic segmentation have an excellent percentage of reproducibility and repeatability (intra-CC > 0.9). In conclusion, semi-automated segmentation is recommended for inter-observer study while manual segmentation with soft tissue-windowing can be used for single observer study.
Collapse
|
6
|
Automated Classification of Atherosclerotic Radiomics Features in Coronary Computed Tomography Angiography (CCTA). Diagnostics (Basel) 2022; 12:diagnostics12071660. [PMID: 35885564 PMCID: PMC9318450 DOI: 10.3390/diagnostics12071660] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 06/23/2022] [Accepted: 07/01/2022] [Indexed: 12/24/2022] Open
Abstract
Radiomics is the process of extracting useful quantitative features of high-dimensional data that allows for automated disease classification, including atherosclerotic disease. Hence, this study aimed to quantify and extract the radiomic features from Coronary Computed Tomography Angiography (CCTA) images and to evaluate the performance of automated machine learning (AutoML) model in classifying the atherosclerotic plaques. In total, 202 patients who underwent CCTA examination at Institut Jantung Negara (IJN) between September 2020 and May 2021 were selected as they met the inclusion criteria. Three primary coronary arteries were segmented on axial sectional images, yielding a total of 606 volume of interest (VOI). Subsequently, the first order, second order, and shape order of radiomic characteristics were extracted for each VOI. Model 1, Model 2, Model 3, and Model 4 were constructed using AutoML-based Tree-Pipeline Optimization Tools (TPOT). The heatmap confusion matrix, recall (sensitivity), precision (PPV), F1 score, accuracy, receiver operating characteristic (ROC), and area under the curve (AUC) were analysed. Notably, Model 1 with the first-order features showed superior performance in classifying the normal coronary arteries (F1 score: 0.88; Inverse F1 score: 0.94), as well as in classifying the calcified (F1 score: 0.78; Inverse F1 score: 0.91) and mixed plaques (F1 score: 0.76; Inverse F1 score: 0.86). Moreover, Model 2 consisting of second-order features was proved useful, specifically in classifying the non-calcified plaques (F1 score: 0.63; Inverse F1 score: 0.92) which are a key point for prediction of cardiac events. Nevertheless, Model 3 comprising the shape-based features did not contribute to the classification of atherosclerotic plaques. Overall, TPOT shown promising capabilities in terms of finding the best pipeline and tailoring the model using CCTA-based radiomic datasets.
Collapse
|
7
|
Aupongkaroon P, Makarawate P, Chaosuwannakit N. Comparison of radiation dose and its correlates between coronary computed tomography angiography and invasive coronary angiography in Northeastern Thailand. Egypt Heart J 2022; 74:6. [PMID: 35076784 PMCID: PMC8789964 DOI: 10.1186/s43044-022-00241-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 01/14/2022] [Indexed: 11/24/2022] Open
Abstract
Background The number of coronary computed tomography angiography (CCTA) exams is steadily growing. A novel computed tomography (CT) system has been developed to increase image quality while lowering patient radiation. The radiation dose attributed to CCTA has received considerable attention, whereas the dose associated with invasive catheter angiography (ICA) has received less. This study aims to investigate the radiation exposure of CCTA in patients and compare it to ICA. Results The mean effective dose of CCTA was 2.88 ± 0.85 mSv which was significantly lower than the mean effective dose of ICA (5.61 ± 0.55 mSv), p < 0.0001. The effective dose of CCTA correlated with the weight, height, and BMI, while the effective dose of ICA was associated with patient weight and BMI. The radiation exposure from CCTA has been considerably reduced over the last ten years by almost 2.5 folds. The mean radiation dose from the newer generation CT used in 2019 was significantly lower than that of the single-source CT in 2010 (2.88 ± 0.85 mSv vs. 7.15 ± 3.4 mSv, p < 0.001). Conclusions CCTA allows evaluation of CAD with a significantly less effective radiation dose to patients than diagnostic ICA. There was a significant decrease in radiation dose from CCTA over time. Regular measurement of patient doses is an essential step to optimize exposure. It makes operators aware of their performance and allows comparisons with generally accepted practices.
Collapse
Affiliation(s)
| | - Pattarapong Makarawate
- Cardiology Unit, Internal Medicine Department, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
| | - Narumol Chaosuwannakit
- Radiology Department, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40000, Thailand.
| |
Collapse
|
8
|
Kayun Z, Abdul Karim MK, Harun HH, Shaari AH, Mahmud R, Hamid HA, Sabarudin A, Chew MT. Radiation doses and size-specific dose estimate from CT brain examinations according to head sizes in a tertiary hospital in Malaysia. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109694] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
9
|
Willemink MJ, Varga-Szemes A, Schoepf UJ, Codari M, Nieman K, Fleischmann D, Mastrodicasa D. Emerging methods for the characterization of ischemic heart disease: ultrafast Doppler angiography, micro-CT, photon-counting CT, novel MRI and PET techniques, and artificial intelligence. Eur Radiol Exp 2021; 5:12. [PMID: 33763754 PMCID: PMC7991013 DOI: 10.1186/s41747-021-00207-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Accepted: 01/22/2021] [Indexed: 12/24/2022] Open
Abstract
After an ischemic event, disruptive changes in the healthy myocardium may gradually develop and may ultimately turn into fibrotic scar. While these structural changes have been described by conventional imaging modalities mostly on a macroscopic scale-i.e., late gadolinium enhancement at magnetic resonance imaging (MRI)-in recent years, novel imaging methods have shown the potential to unveil an even more detailed picture of the postischemic myocardial phenomena. These new methods may bring advances in the understanding of ischemic heart disease with potential major changes in the current clinical practice. In this review article, we provide an overview of the emerging methods for the non-invasive characterization of ischemic heart disease, including coronary ultrafast Doppler angiography, photon-counting computed tomography (CT), micro-CT (for preclinical studies), low-field and ultrahigh-field MRI, and 11C-methionine positron emission tomography. In addition, we discuss new opportunities brought by artificial intelligence, while addressing promising future scenarios and the challenges for the application of artificial intelligence in the field of cardiac imaging.
Collapse
Affiliation(s)
- Martin J. Willemink
- grid.168010.e0000000419368956Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA 94035 USA
| | - Akos Varga-Szemes
- grid.259828.c0000 0001 2189 3475Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC USA
| | - U. Joseph Schoepf
- grid.259828.c0000 0001 2189 3475Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC USA
| | - Marina Codari
- grid.168010.e0000000419368956Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA 94035 USA
| | - Koen Nieman
- grid.168010.e0000000419368956Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA USA ,Stanford Cardiovascular Institute, Stanford, CA 94305 USA
| | - Dominik Fleischmann
- grid.168010.e0000000419368956Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA 94035 USA ,Stanford Cardiovascular Institute, Stanford, CA 94305 USA
| | - Domenico Mastrodicasa
- Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94035, USA. .,Stanford Cardiovascular Institute, Stanford, CA, 94305, USA.
| |
Collapse
|
10
|
The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2020.108989] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
11
|
García-Hernández T, Romero-Expósito M, Sánchez-Nieto B. Low dose radiation therapy for COVID-19: Effective dose and estimation of cancer risk. Radiother Oncol 2020; 153:289-295. [PMID: 33065184 PMCID: PMC7553901 DOI: 10.1016/j.radonc.2020.09.051] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 09/16/2020] [Accepted: 09/27/2020] [Indexed: 01/11/2023]
Abstract
BACKGROUND AND PURPOSE The objective of this work is to evaluate the risk of carcinogenesis of low dose ionizing radiation therapy (LDRT), for treatment of immune-related pneumonia following COVID-19 infection, through the estimation of effective dose and the lifetime attributable risk of cancer (LAR). MATERIAL AND METHODS LDRT treatment was planned in male and female computational phantoms. Equivalent doses in organs were estimated using both treatment planning system calculations and a peripheral dose model (based on ionization chamber measurements). Skin dose was estimated using radiochromic films. Later, effective dose and LAR were calculated following radiation protection procedures. RESULTS Equivalent doses to organs per unit of prescription dose range from 10 mSv/cGy to 0.0051 mSv/cGy. Effective doses range from 204 mSv to 426 mSv, for prescription doses ranging from 50 cGy to 100 cGy. Total LAR for a prescription dose of 50 cGy ranges from 1.7 to 0.29% for male and from 4.9 to 0.54% for female, for ages ranging from 20 to 80 years old. CONCLUSIONS The organs that mainly contribute to risk are lung and breast. Risk for out-of-field organs is low, less than 0.06 cases per 10000. Female LAR is on average 2.2 times that of a male of the same age. Effective doses are of the same order of magnitude as the higher-dose interventional radiology techniques. For a 60 year-old male, LAR is 8 times that from a cardiac CT, when prescription dose is 50 cGy.
Collapse
Affiliation(s)
| | - Maite Romero-Expósito
- Área de Ciencias Básicas y Ambientales, Instituto Tecnológico de Santo Domingo (INTEC), P.O. Box 342-9/249-2, Santo Domingo, Dominican Republic
| | | |
Collapse
|
12
|
Establishment of CTPA Local Diagnostic Reference Levels with Noise Magnitude as a Quality Indicator in a Tertiary Care Hospital. Diagnostics (Basel) 2020; 10:diagnostics10090680. [PMID: 32916913 PMCID: PMC7555305 DOI: 10.3390/diagnostics10090680] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/12/2020] [Accepted: 08/14/2020] [Indexed: 12/16/2022] Open
Abstract
This study aimed to establish the local diagnostic reference levels (LDRLs) of computed tomography pulmonary angiography (CTPA) examinations based on body size with regard to noise magnitude as a quality indicator. The records of 127 patients (55 males and 72 females) who had undergone CTPAs using a 128-slice CT scanner were retrieved. The dose information, scanning acquisition parameters, and patient demographics were recorded in standardized forms. The body size of patients was categorized into three groups based on their anteroposterior body length: P1 (14–19 cm), P2 (19–24 cm), and P3 (24–31 cm), and the radiation dose exposure was statistically compared. The image noise was determined quantitatively by measuring the standard deviation of the region of interest (ROI) at five different arteries—the ascending and descending aorta, pulmonary trunk, and the left and right main pulmonary arteries. We observed that the LDRL values were significantly different between body sizes (p < 0.05), and the median values of the CT dose index volume (CTDIvol) for P1, P2, and P3 were 6.13, 8.3, and 21.40 mGy, respectively. It was noted that the noise reference values were 23.78, 24.26, and 23.97 HU for P1, P2, and P3, respectively, which were not significantly different from each other (p > 0.05). The CTDIvol of 9 mGy and dose length product (DLP) of 329 mGy∙cm in this study were lower than those reported by other studies conducted elsewhere. This study successfully established the LDRLs of a local healthcare institution with the inclusion of the noise magnitude, which is comparable with other established references.
Collapse
|
13
|
Choi SJ, Ahn SJ, Park SH, Park SH, Pak SY, Choi JW, Shim YS, Jeong YM, Kim B. Dual-source abdominopelvic computed tomography: Comparison of image quality and radiation dose of 80 kVp and 80/150 kVp with tin filter. PLoS One 2020; 15:e0231431. [PMID: 32881876 PMCID: PMC7470424 DOI: 10.1371/journal.pone.0231431] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 08/19/2020] [Indexed: 12/05/2022] Open
Abstract
Objective To compare the radiation dose and the objective and subjective image quality of 80 kVp and 80/150 kVp with tin filter (80/Sn150 kVp) computed tomography (CT) in oncology patients. Methods One-hundred-and-forty-five consecutive oncology patients who underwent third-generation dual-source dual-energy CT of the abdomen for evaluation of malignant visceral, peritoneal, extraperitoneal, and bone tumor were retrospectively recruited. Two radiologists independently reviewed each observation in 80 kVp CT and 80/Sn150 kVp CT. Modified line-density profile of the tumor and contrast-to-noise ratio (CNR) were measured. Diagnostic confidence, lesion conspicuity, and subjective image quality were calculated and compared between image sets. The effective dose and size-specific dose estimate (SSDE) were calculated in the image sets. Results Modified line-density profile analysis revealed higher attenuation differences between the tumor and normal tissue in 80 kVp CT than in 80/Sn150 kVp CT (127 vs. 107, P = 0.05). The 80 kVp CT showed increased CNR in the liver (8.0 vs. 7.6) and the aorta (18.9 vs. 16.3) than the 80/Sn150 kVp CT. The 80 kVp CT yielded higher enhancement of organs (4.9 ± 0.2 vs. 4.7 ± 0.4, P<0.001) and lesion conspicuity (4.9 ± 0.3 vs. 4.8 ± 0.5, P = 0.035) than the 80/Sn150 kVp CT; overall image quality and confidence index were comparable. The effective dose was reduced by 45.2% with 80 kVp CT (2.3 mSv ± 0.9) compared to 80/Sn150 kVp CT (4.1 mSv ± 1.5). The SSDE was 7.4 ± 3.8 mGy on 80/Sn150 kVp CT and 4.1 ± 2.2 mGy on 80 kVp CT. Conclusions The 80 kVp CT reduced the radiation dose by 45.2% in oncology patients while showing comparable or superior image quality to that of 80/Sn150 kVp CT for abdominal tumor evaluation.
Collapse
Affiliation(s)
- Seung Joon Choi
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Su Joa Ahn
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - So Hyun Park
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
- * E-mail:
| | - Seong Ho Park
- Division of Abdominal Radiology, Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Seong Yong Pak
- Imaging and Computer Vision Division, Siemens Healthcare, Seoul, Korea
| | - Jae Won Choi
- Imaging and Computer Vision Division, Siemens Healthcare, Seoul, Korea
| | - Young Sup Shim
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Yu Mi Jeong
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
| | - Bohyun Kim
- Department of Radiology, Seoul Saint Mary's Hospital, Seoul, Korea
| |
Collapse
|
14
|
Muhammad N, Karim M, Hassan H, Kamarudin M, Wong J, Ibahim M. Estimation of effective dose and organ cancer risk from paediatric computed tomography thorax – Abdomen - Pelvis examinations. Radiat Phys Chem Oxf Engl 1993 2019. [DOI: 10.1016/j.radphyschem.2019.108438] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
15
|
Karim MKA, Sabarudin A, Muhammad NA, Ng KH. A comparative study of radiation doses between phantom and patients via CT angiography of the intra-/extra-cranial, pulmonary, and abdominal/pelvic arteries. Radiol Phys Technol 2019; 12:374-381. [PMID: 31468370 DOI: 10.1007/s12194-019-00532-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 08/09/2019] [Accepted: 08/10/2019] [Indexed: 10/26/2022]
Abstract
This study aimed to evaluate effective dose and size-specific dose estimate (SSDE) of computed tomography angiography (CTA) examination using an anthropomorphic phantom. We included three CTA examination protocols to evaluate the intra- and extra-cranial arteries, pulmonary artery (CTPA), and abdominal vessels. Patient SSDEs were measured retrospectively to estimate patient dose, relative to the bodyweight of the patient and volume CT dose index (CTDIvol). Our findings revealed that the highest dose was absorbed by the left lobe of the thyroid gland during intra-/extra-cranial CTA and CTPA, that is, 14.11 ± 0.24 mGy and 16.20 ± 3.95 mGy, respectively. However, the highest absorbed dose in abdominal/pelvic CTA was the gonads (8.98 ± 0.30 mGy), while other radiosensitive organs in intra- and extra-cranial CTA, CTPA, and abdominal/pelvic CTA did not demonstrate significant differences between organs/structures with p value 0.88, 0.11, and 0.54, respectively. The estimated effective dose in intra-/extra-cranial CTA was lower in patients (0.80 ± 0.60 mSv) than in the phantom (0.83 mSv), but it was the opposite for CTPA, with the effective dose being higher in patients (7.54 ± 3.09 mSv) than in the phantom (6.68 mSv). Similar to the effective dose, only CTPA SSDEs were significantly higher in men than in women (19.74 ± 4.79 mGy versus 7.9 mGy). Effective dose and SSDE are clinically relevant parameters that can help estimate a more accurate patient dose based on a patient's size.
Collapse
Affiliation(s)
- M K A Karim
- Department of Physics, Faculty of Science, Universiti Putra Malaysia, 43400, Serdang, Selangor, Malaysia.
| | - A Sabarudin
- Programme of Diagnostic Imaging and Radiotherapy, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 56000, Kuala Lumpur, Malaysia
| | - N A Muhammad
- Department of Physics, Faculty of Science, Universiti Putra Malaysia, 43400, Serdang, Selangor, Malaysia
| | - K H Ng
- Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| |
Collapse
|