1
|
Khan AA, Kim JH. Recent advances in materials and manufacturing of implantable devices for continuous health monitoring. Biosens Bioelectron 2024; 261:116461. [PMID: 38850737 DOI: 10.1016/j.bios.2024.116461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 04/30/2024] [Accepted: 06/01/2024] [Indexed: 06/10/2024]
Abstract
Implantable devices are vital in healthcare, enabling continuous monitoring, early disease detection, informed decision-making, enhanced outcomes, cost reduction, and chronic condition management. These devices provide real-time data, allowing proactive healthcare interventions, and contribute to overall improvements in patient care and quality of life. The success of implantable devices relies on the careful selection of materials and manufacturing methods. Recent materials research and manufacturing advancements have yielded implantable devices with enhanced biocompatibility, reliability, and functionality, benefiting human healthcare. This paper provides a comprehensive overview of the latest developments in implantable medical devices, emphasizing the importance of material selection and manufacturing methods, including biocompatibility, self-healing capabilities, corrosion resistance, mechanical properties, and conductivity. It explores various manufacturing techniques such as microfabrication, 3D printing, laser micromachining, electrospinning, screen printing, inkjet printing, and nanofabrication. The paper also discusses challenges and limitations in the field, including biocompatibility concerns, privacy and data security issues, and regulatory hurdles for implantable devices.
Collapse
Affiliation(s)
- Akib Abdullah Khan
- School of Engineering and Computer Science, Washington State University, Vancouver, WA, 98686, USA
| | - Jong-Hoon Kim
- School of Engineering and Computer Science, Washington State University, Vancouver, WA, 98686, USA; Department of Mechanical Engineering, University of Washington, WA, 98195, USA.
| |
Collapse
|
2
|
Wang J, Chu J, Song J, Li Z. The application of impantable sensors in the musculoskeletal system: a review. Front Bioeng Biotechnol 2024; 12:1270237. [PMID: 38328442 PMCID: PMC10847584 DOI: 10.3389/fbioe.2024.1270237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 01/08/2024] [Indexed: 02/09/2024] Open
Abstract
As the population ages and the incidence of traumatic events rises, there is a growing trend toward the implantation of devices to replace damaged or degenerated tissues in the body. In orthopedic applications, some implants are equipped with sensors to measure internal data and monitor the status of the implant. In recent years, several multi-functional implants have been developed that the clinician can externally control using a smart device. Experts anticipate that these versatile implants could pave the way for the next-generation of technological advancements. This paper provides an introduction to implantable sensors and is structured into three parts. The first section categorizes existing implantable sensors based on their working principles and provides detailed illustrations with examples. The second section introduces the most common materials used in implantable sensors, divided into rigid and flexible materials according to their properties. The third section is the focal point of this article, with implantable orthopedic sensors being classified as joint, spine, or fracture, based on different practical scenarios. The aim of this review is to introduce various implantable orthopedic sensors, compare their different characteristics, and outline the future direction of their development and application.
Collapse
Affiliation(s)
- Jinzuo Wang
- Department of Orthopaedics, First Affiliated Hospital of Dalian Medical University, Dalian, China
- Key Laboratory of Molecular Mechanism for Repair and Remodeling of Orthopaedic Diseases, Dalian, Liaoning, China
| | - Jian Chu
- Department of Engineering Mechanics, Dalian University of Technology, Dalian, China
| | - Jinhui Song
- Department of Engineering Mechanics, Dalian University of Technology, Dalian, China
| | - Zhonghai Li
- Department of Orthopaedics, First Affiliated Hospital of Dalian Medical University, Dalian, China
- Key Laboratory of Molecular Mechanism for Repair and Remodeling of Orthopaedic Diseases, Dalian, Liaoning, China
| |
Collapse
|
3
|
Ramos A, Soares Dos Santos MP. Capacitive stimulation-sensing system for instrumented bone implants: Finite element model to predict the electric stimuli delivered to the interface. Comput Biol Med 2023; 154:106542. [PMID: 36680932 DOI: 10.1016/j.compbiomed.2023.106542] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 12/17/2022] [Accepted: 01/10/2023] [Indexed: 01/19/2023]
Abstract
BACKGROUND Prevalence of orthopaedic replacements are increasing around the world. The main cause of revision remains associated to the interface loosening. In this work, a computational study using the Finite element method was developed to predict the electric field stimuli delivered to trabecular bone structures, as well as to predict the sensing ability to detect different bone-implant interface scenarios. METHODS Three finite element models were developed: two simplified models, including a Gyroid TMP structure, and a realistic model based on microCT scan of a trabecular bone from sheep vertebra. Simulations were performed using a co-surface capacitive technology for stimulating and sensing bone-implant interfaces. Different fixation scenarios were considered, namely by establishing bone-stimulator gap sizes up to 1 mm (from fixation to massive loosening scenario). Electrodes were excited with sinusoidal and square electric signals up to 10V voltage and 64kHz frequency. RESULTS Simplification of bone geometry resulted in significant electric stimuli differences compared to the realistic bone geometry. Realistic modelling allowed to observe that, in the fixation scenario, the electric field stimuli decreased 85% from the sensor interface to a parallel plane 2 mm apart from such interface. A significant influence of the bone-stimulator distance on the electric stimuli was found: the electric stimuli magnitudes varied in the range between 0.38 V/mm (fixation scenario) and 4.8 mV/mm (massive loosening scenario) for voltages up to 10V. Strong frequency-dependent behaviours were also observed in the electric stimuli: their magnitudes can reach 106-fold decreases when the excitation frequency is decreased from 32 kHz to 14 Hz CONCLUSION: This study points out the inability of our two simplified models to predict the electric stimulation provided to different bone-implant interface scenarios. Results highlight that co-surface stimulators can deliver osteogenic electric stimuli along trabecular bone structures, ensuring low electric power excitations. Moreover, realistic models strongly enhance the sensing predictability of the bone-implant fixation states. These new and significant evidences provide a strong support to integrate co-surface capacitive into bioelectronic implants for both therapeutic and sensing operations.
Collapse
Affiliation(s)
- António Ramos
- TEMA, Mechanical Engineering Department, University of Aveiro, Portugal.
| | | |
Collapse
|
4
|
Conceição C, Completo A, Soares dos Santos MP. Ultrasensitive capacitive sensing system for smart medical devices with ability to monitor fracture healing stages. J R Soc Interface 2023; 20:20220818. [PMCID: PMC9943881 DOI: 10.1098/rsif.2022.0818] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023] Open
Abstract
Bone fractures are a global public health problem. A sustained increase in the number of incident cases has been observed in the last few decades, as well as the number of prevalent cases and the number of years lived with disability. Current monitoring techniques are based on imaging techniques, which are highly subjective, radioactive, expensive and unable to provide daily monitoring of fracture healing stages. The development of reliable, non-invasive and non-subjective technologies is mandatory to minimize non-union risks. Delayed healing and non-union conditions require timely medical intervention, such that preventive procedures and shortened treatment periods can be carried out. This work proposes the development of an ultrasensitive capacitive sensing system for smart implantable fixation implants with ability to effectively monitor the evolution of bone fractures. Both in vitro experimental tests and numerical simulations highlight that networks of co-surface capacitive systems are able: (i) to detect four different bone healing phases, capacitance decrease patterns occurring as the healing process progresses and (ii) to monitor the callus evolution in multiple target regions. These are very promising results that highlight the potential of capacitive technologies to minimize the individual and social burdens related to fracture management, mainly when delayed healing or non-union conditions occur.
Collapse
Affiliation(s)
- Cassandra Conceição
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Completo
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal,TEMA—Centre for Mechanical Technology and Automation, 3810-193 Aveiro, Portugal,LASI—Intelligent Systems Associate Laboratory, Portugal
| | - Marco P. Soares dos Santos
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal,TEMA—Centre for Mechanical Technology and Automation, 3810-193 Aveiro, Portugal,LASI—Intelligent Systems Associate Laboratory, Portugal
| |
Collapse
|
5
|
Soares Dos Santos MP, Bernardo RMC. Bioelectronic multifunctional bone implants: recent trends. Bioelectron Med 2022; 8:15. [PMID: 36127721 PMCID: PMC9490885 DOI: 10.1186/s42234-022-00097-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 08/23/2022] [Indexed: 12/04/2022] Open
Abstract
The concept of Instrumented Smart Implant emerged as a leading research topic that aims to revolutionize the field of orthopaedic implantology. These implants have been designed incorporating biophysical therapeutic actuation, bone-implant interface sensing, implant-clinician communication and self-powering ability. The ultimate goal is to implement revist interface, controlled by clinicians/surgeons without troubling the quotidian activities of patients. Developing such high-performance technologies is of utmost importance, as bone replacements are among the most performed surgeries worldwide and implant failure rates can still exceed 10%. In this review paper, an overview to the major breakthroughs carried out in the scope of multifunctional smart bone implants is provided. One can conclude that many challenges must be overcome to successfully develop them as revision-free implants, but their many strengths highlight a huge potential to effectively establish a new generation of high-sophisticated biodevices.
Collapse
Affiliation(s)
- Marco P Soares Dos Santos
- Department of Mechanical Engineering, Centre for Mechanical Technology & Automation (TEMA), Intelligent Systems Associate Laboratory (LASI), University of Aveiro, Aveiro, Portugal.
| | - Rodrigo M C Bernardo
- Department of Mechanical Engineering, Centre for Mechanical Technology & Automation (TEMA), Intelligent Systems Associate Laboratory (LASI), University of Aveiro, Aveiro, Portugal
| |
Collapse
|
6
|
Peres I, Rolo P, Soares Dos Santos MP. Multifunctional Smart Bone Implants: Fiction or Future?-A New Perspective. Front Bioeng Biotechnol 2022; 10:912081. [PMID: 35757794 PMCID: PMC9216553 DOI: 10.3389/fbioe.2022.912081] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Accepted: 05/13/2022] [Indexed: 11/13/2022] Open
Abstract
Implantable medical devices have been developed to provide multifunctional ability to numerous bioapplications. In the scope of orthopaedics, four methodologies were already proposed to design implant technologies: non-instrumented passive implants, non-instrumented active implants, instrumented passive implants and instrumented active implants. Even though bone replacements are among the most performed surgeries worldwide, implant failure rates can still exceed 10%. Controversial positions multiply in the scientific community about the potential of each methodology to minimize the burden related to implant failures. In this perspective paper, we argue that the next technological revolution in the field of implantable bone devices will most likely emerge with instrumented active implants as multifunctional smart devices extracorporeally controlled by clinicians/surgeons. Moreover, we provide a new perspective about implant technology: the essence of instrumented implants is to enclose a hybrid architecture in which optimal implant performances require both smart instrumentation and smart coatings, although the implant controllability must be ensured by extracorporeal systems.
Collapse
Affiliation(s)
- Inês Peres
- Department of Mechanical Engineering, Centre for Mechanical Technology and Automation (TEMA), University of Aveiro, Aveiro, Portugal
| | - Pedro Rolo
- Department of Mechanical Engineering, Centre for Mechanical Technology and Automation (TEMA), University of Aveiro, Aveiro, Portugal
| | - Marco P Soares Dos Santos
- Department of Mechanical Engineering, Centre for Mechanical Technology and Automation (TEMA), University of Aveiro, Aveiro, Portugal
| |
Collapse
|
7
|
Abstract
Motion-driven electromagnetic energy harvesting is a well-suited technological solution to autonomously power a broad range of autonomous devices. Although different harvester configurations and mechanisms have been already proposed to perform effective tuning and broadband harvesting, no methodology has proven to be effective to maximize the harvester performance for unknown and time-varying patterns of mechanical power sources externally exciting the harvesters. This paper provides, for the first time, a radically new concept of energy harvester to maximize the harvested energy for time-varying excitations: the self-adaptive electromagnetic energy harvester. This research work aims to analyze the electric energy harvesting gain when self-adaptive electromagnetic harvesters, using magnetic levitation architectures, are able to autonomously adapt their architecture as variations in the excitation patterns occur. This was accomplished by identifying the optimal harvester length for different excitation patterns and load resistances. Gains related to electric current and power exceeding 100 can be achieved for small-scale harvesters. The paper also describes comprehensive case studies to verify the feasibility of the self-adaptive harvester, considering the energy demand from the adaptive mechanism, namely the sensing, processing and actuation systems. These successful results highlight the potential of this innovative methodology to design highly sophisticated energy harvesters, both for a small- and large-scale power supply.
Collapse
|
8
|
Multiscale Sensing of Bone-Implant Loosening for Multifunctional Smart Bone Implants: Using Capacitive Technologies for Precision Controllability. SENSORS 2022; 22:s22072531. [PMID: 35408143 PMCID: PMC9003018 DOI: 10.3390/s22072531] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 03/16/2022] [Accepted: 03/23/2022] [Indexed: 02/06/2023]
Abstract
The world population growth and average life expectancy rise have increased the number of people suffering from non-communicable diseases, namely osteoarthritis, a disorder that causes a significant increase in the years lived with disability. Many people who suffer from osteoarthritis undergo replacement surgery. Despite the relatively high success rate, around 10% of patients require revision surgeries, mostly because existing implant technologies lack sensing devices capable of monitoring the bone–implant interface. Among the several monitoring methodologies already proposed as substitutes for traditional imaging methods, cosurface capacitive sensing systems hold the potential to monitor the bone–implant fixation states, a mandatory capability for long-term implant survival. A multifaceted study is offered here, which covers research on the following points: (1) the ability of a cosurface capacitor network to effectively monitor bone loosening in extended peri-implant regions and according to different stimulation frequencies; (2) the ability of these capacitive architectures to provide effective sensing in interfaces with hydroxyapatite-based layers; (3) the ability to control the operation of cosurface capacitive networks using extracorporeal informatic systems. In vitro tests were performed using a web-based network sensor composed of striped and interdigitated capacitive sensors. Hydroxyapatite-based layers have a minor effect on determining the fixation states; the effective operation of a sensor network-based solution communicating through a web server hosted on Raspberry Pi was shown. Previous studies highlight the inability of current bone–implant fixation monitoring methods to significantly reduce the number of revision surgeries, as well as promising results of capacitive sensing systems to monitor micro-scale and macro-scale bone–interface states. In this study, we found that extracorporeal informatic systems enable continuous patient monitoring using cosurface capacitive networks with or without hydroxyapatite-based layers. Findings presented here represent significant advancements toward the design of future multifunctional smart implants.
Collapse
|
9
|
Chen Y, Liu Y, Li Y, Wang G, Chen M. An Energy-Efficient ASK Demodulator Robust to Power-Carrier-Interference for Inductive Power and Data Telemetry. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:108-118. [PMID: 35104224 DOI: 10.1109/tbcas.2022.3146559] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Wireless power and datatelemetry based on amplitude-shift keying (ASK) modulation over dual inductive links has been widely adopted in biomedical implants. Due to the mutual inductance between the power and data links, the large power-carrier-interference (PCI) will inevitably cause low signal-to-interference ratio (SIR) of the received signal, thereby increasing the bit-error-rate (BER) of the ASK demodulation. In this paper, an innovative high energy-efficient ASK demodulator robust to PCI has been proposed. Thanks to the proposed sampling-and-subtraction (SAS) architecture, the demodulator is capable of withstanding PCI with an amplitude up to 2.5 times as the data carrier without the need for any high-order filters. The prototype has been implemented with 180 nm standard CMOS process, occupying a core area of 0.51 mm 2. The experimental results show that with 1 Mbps data rate and 13.56 MHz carrier frequency, the typical BER is less than 1.3×10 -3, while the energy efficiency is 280 pJ/bit, showing 7.5× improvement compared to the prior works. The energy-efficient robustness to PCI demonstrates the potential of the technique to be applied to retina prostheses as well as various kinds of ultra-low-power implantable biomedical devices.
Collapse
|
10
|
de Sousa BM, Correia CR, Ferreira JAF, Mano JF, Furlani EP, Soares Dos Santos MP, Vieira SI. Capacitive interdigitated system of high osteoinductive/conductive performance for personalized acting-sensing implants. NPJ Regen Med 2021; 6:80. [PMID: 34815414 PMCID: PMC8611088 DOI: 10.1038/s41536-021-00184-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 10/19/2021] [Indexed: 11/15/2022] Open
Abstract
Replacement orthopedic surgeries are among the most common surgeries worldwide, but clinically used passive implants cannot prevent failure rates and inherent revision arthroplasties. Optimized non-instrumented implants, resorting to preclinically tested bioactive coatings, improve initial osseointegration but lack long-term personalized actuation on the bone-implant interface. Novel bioelectronic devices comprising biophysical stimulators and sensing systems are thus emerging, aiming for long-term control of peri-implant bone growth through biointerface monitoring. These acting-sensing dual systems require high frequency (HF) operations able to stimulate osteoinduction/osteoconduction, including matrix maturation and mineralization. A sensing-compatible capacitive stimulator of thin interdigitated electrodes and delivering an electrical 60 kHz HF stimulation, 30 min/day, is here shown to promote osteoconduction in pre-osteoblasts and osteoinduction in human adipose-derived mesenchymal stem cells (hASCs). HF stimulation through this capacitive interdigitated system had significant effects on osteoblasts' collagen-I synthesis, matrix, and mineral deposition. A proteomic analysis of microvesicles released from electrically-stimulated osteoblasts revealed regulation of osteodifferentiation and mineralization-related proteins (e.g. Tgfb3, Ttyh3, Itih1, Aldh1a1). Proteomics data are available via ProteomeXchange with the identifier PXD028551. Further, under HF stimulation, hASCs exhibited higher osteogenic commitment and enhanced hydroxyapatite deposition. These promising osteoinductive/conductive capacitive stimulators will integrate novel bioelectronic implants able to monitor the bone-implant interface and deliver personalized stimulation to peri-implant tissues.
Collapse
Affiliation(s)
- Bárbara M de Sousa
- Department of Medical Sciences, Institute of Biomedicine (iBiMED), University of Aveiro, 3810-193, Aveiro, Portugal
| | - Clara R Correia
- Department of Chemistry, CICECO - Aveiro Institute of Materials, University of Aveiro, 3810-193, Aveiro, Portugal
| | - Jorge A F Ferreira
- Department of Mechanical Engineering, Centre for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193, Aveiro, Portugal
| | - João F Mano
- Department of Chemistry, CICECO - Aveiro Institute of Materials, University of Aveiro, 3810-193, Aveiro, Portugal
| | - Edward P Furlani
- Department of Chemical and Biological Engineering, Department of Electrical Engineering, University at Buffalo (SUNY), Buffalo, NY, 14260, USA
| | - Marco P Soares Dos Santos
- Department of Mechanical Engineering, Centre for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193, Aveiro, Portugal.
- Faculty of Engineering, Associated Laboratory for Energy, Transports and Aeronautics (LAETA), University of Porto, 4200-465, Porto, Portugal.
| | - Sandra I Vieira
- Department of Medical Sciences, Institute of Biomedicine (iBiMED), University of Aveiro, 3810-193, Aveiro, Portugal.
| |
Collapse
|
11
|
Vidal JV, Slabov V, Kholkin AL, Dos Santos MPS. Hybrid Triboelectric-Electromagnetic Nanogenerators for Mechanical Energy Harvesting: A Review. NANO-MICRO LETTERS 2021; 13:199. [PMID: 34542731 PMCID: PMC8452823 DOI: 10.1007/s40820-021-00713-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Accepted: 07/26/2021] [Indexed: 05/27/2023]
Abstract
Motion-driven electromagnetic-triboelectric energy generators (E-TENGs) hold a great potential to provide higher voltages, higher currents and wider operating bandwidths than both electromagnetic and triboelectric generators standing alone. Therefore, they are promising solutions to autonomously supply a broad range of highly sophisticated devices. This paper provides a thorough review focused on major recent breakthroughs in the area of electromagnetic-triboelectric vibrational energy harvesting. A detailed analysis was conducted on various architectures including rotational, pendulum, linear, sliding, cantilever, flexible blade, multidimensional and magnetoelectric, and the following hybrid technologies. They enable highly efficient ways to harvest electric energy from many forms of vibrational, rotational, biomechanical, wave, wind and thermal sources, among others. Open-circuit voltages up to 75 V, short-circuit currents up to 60 mA and instantaneous power up to 144 mW were already achieved by these nanogenerators. Their transduction mechanisms, including proposed models to make intelligible the involved physical phenomena, are also overviewed here. A comprehensive analysis was performed to compare their respective construction designs, external excitations and electric outputs. The results highlight the potential of hybrid E-TENGs to convert unused mechanical motion into electric energy for both large- and small-scale applications. Finally, this paper proposes future research directions toward optimization of energy conversion efficiency, power management, durability and stability, packaging, energy storage, operation input, research of transduction mechanisms, quantitative standardization, system integration, miniaturization and multi-energy hybrid cells.
Collapse
Affiliation(s)
- João V Vidal
- Department of Physics and CICECO - Aveiro Institute of Materials, University of Aveiro, 3810-193, Aveiro, Portugal.
- Department of Physics and I3N, University of Aveiro, 3810-193, Aveiro, Portugal.
| | - Vladislav Slabov
- Department of Physics and CICECO - Aveiro Institute of Materials, University of Aveiro, 3810-193, Aveiro, Portugal
| | - Andrei L Kholkin
- Department of Physics and CICECO - Aveiro Institute of Materials, University of Aveiro, 3810-193, Aveiro, Portugal.
- Laboratory of Functional Low-Dimensional Structures, National University of Science and Technology MISIS, Moscow, Russia.
| | - Marco P Soares Dos Santos
- Department of Mechanical Engineering, Centre for Mechanical Technology and Automation (TEMA), University of Aveiro, 3810-193, Aveiro, Portugal
| |
Collapse
|
12
|
Wu L, Liu T, Wang J. Improving the Effect of Transcranial Alternating Current Stimulation (tACS): A Systematic Review. Front Hum Neurosci 2021; 15:652393. [PMID: 34163340 PMCID: PMC8215166 DOI: 10.3389/fnhum.2021.652393] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 04/26/2021] [Indexed: 11/15/2022] Open
Abstract
With the development of electrical stimulation technology, traditional transcranial alternating current stimulation (tACS) technology has been found to have the drawback of not targeting a specific area accurately. Studies have shown that optimizing the number and position of electrodes during electrical stimulation has a very good effect on enhancing brain stimulation accuracy. At present, an increasing number of laboratories have begun to optimize tACS. However, there has been no study summarizing the optimization methods of tACS. Determining whether different optimization methods are effective and the optimization approach could provide information that could guide future tACS research. We describe the results of recent research on tACS optimization and integrate the optimization approaches of tACS in recent research. Optimization approaches can be classified into two groups: high-definition electrical stimulation and interference modulation electrical stimulation. The optimization methods can be divided into five categories: high-definition tACS, phase-shifted tACS, amplitude-modulated tACS, the temporally interfering (TI) method, and the intersectional short pulse (ISP) method. Finally, we summarize the latest research on hardware useful for tACS improvement and outline future directions.
Collapse
Affiliation(s)
- Linyan Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Institute of Health and Rehabilitation Science, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.,National Engineering Research Center of Health Care and Medical Devices, Guangzhou, China.,The Key Laboratory of Neuro-informatics & Rehabilitation Engineering of Ministry of Civil Affairs, Xi'an, China
| | - Tian Liu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Institute of Health and Rehabilitation Science, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.,National Engineering Research Center of Health Care and Medical Devices, Guangzhou, China.,The Key Laboratory of Neuro-informatics & Rehabilitation Engineering of Ministry of Civil Affairs, Xi'an, China
| | - Jue Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Institute of Health and Rehabilitation Science, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.,National Engineering Research Center of Health Care and Medical Devices, Guangzhou, China.,The Key Laboratory of Neuro-informatics & Rehabilitation Engineering of Ministry of Civil Affairs, Xi'an, China
| |
Collapse
|
13
|
Gamero M, Kim WS, Hong S, Vorobiev D, Morgan CD, Park SI. Multimodal Sensing Capabilities for the Detection of Shunt Failure. SENSORS 2021; 21:s21051747. [PMID: 33802445 PMCID: PMC7959456 DOI: 10.3390/s21051747] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 02/12/2021] [Accepted: 02/25/2021] [Indexed: 11/16/2022]
Abstract
Hydrocephalus is a medical condition characterized by the abnormal accumulation of cerebrospinal fluid (CSF) within the cavities of the brain called ventricles. It frequently follows pediatric and adult congenital malformations, stroke, meningitis, aneurysmal rupture, brain tumors, and traumatic brain injury. CSF diversion devices, or shunts, have become the primary therapy for hydrocephalus treatment for nearly 60 years. However, routine treatment complications associated with a shunt device are infection, obstruction, and over drainage. Although some (regrettably, the minority) patients with shunts can go for years without complications, even those lucky few may potentially experience one shunt malfunction; a shunt complication can require emergency intervention. Here, we present a soft, wireless device that monitors distal terminal fluid flow and transmits measurements to a smartphone via a low-power Bluetooth communication when requested. The proposed multimodal sensing device enabled by flow sensors, for measurements of flow rate and electrodes for measurements of resistance in a fluidic chamber, allows precision measurement of CSF flow rate over a long time and under any circumstances caused by unexpected or abnormal events. A universal design compatible with any modern commercial spinal fluid shunt system would enable the widespread use of this technology.
Collapse
Affiliation(s)
- Milenka Gamero
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA; (M.G.); (W.S.K.); (S.H.); (D.V.)
| | - Woo Seok Kim
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA; (M.G.); (W.S.K.); (S.H.); (D.V.)
| | - Sungcheol Hong
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA; (M.G.); (W.S.K.); (S.H.); (D.V.)
| | - Daniel Vorobiev
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA; (M.G.); (W.S.K.); (S.H.); (D.V.)
| | - Clinton D. Morgan
- Department of Neurosurgery, Barrow Neurological Institute, Phoenix, AZ 85013, USA;
| | - Sung Il Park
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA; (M.G.); (W.S.K.); (S.H.); (D.V.)
- Center of Remote Health Sciences and Technologies, Texas A&M University, College Station, TX 77843, USA
- Institute for Neuroscience, Texas A&M University, College Station, TX 77843, USA
- Correspondence: ; Tel.: +1-979-458-8579
| |
Collapse
|
14
|
Towards an effective sensing technology to monitor micro-scale interface loosening of bioelectronic implants. Sci Rep 2021; 11:3449. [PMID: 33568680 PMCID: PMC7876021 DOI: 10.1038/s41598-021-82589-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 01/13/2021] [Indexed: 12/25/2022] Open
Abstract
Instrumented implants are being developed with a radically innovative design to significantly reduce revision surgeries. Although bone replacements are among the most prevalent surgeries performed worldwide, implant failure rate usually surpasses 10%. High sophisticated multifunctional bioelectronic implants are being researched to incorporate cosurface capacitive architectures with ability to deliver personalized electric stimuli to peri-implant target tissues. However, the ability of these architectures to detect bone-implant interface states has never been explored. Moreover, although more than forty technologies were already proposed to detect implant loosening, none is able to ensure effective monitoring of the bone-implant debonding, mainly during the early stages of loosening. This work shows, for the first time, that cosurface capacitive sensors are a promising technology to provide an effective monitoring of bone-implant interfaces during the daily living of patients. Indeed, in vitro experimental tests and simulation with computational models highlight that both striped and circular capacitive architectures are able to detect micro-scale and macro-scale interface bonding, debonding or loosening, mainly when bonding is weakening or loosening is occurring. The proposed cosurface technologies hold potential to implement highly effective and personalized sensing systems such that the performance of multifunctional bioelectronic implants can be strongly improved. Findings were reported open a new research line on sensing technologies for bioelectronic implants, which may conduct to great impacts in the coming years.
Collapse
|
15
|
Konstantinou E, Zagoriti Z, Pyriochou A, Poulas K. Microcurrent Stimulation Triggers MAPK Signaling and TGF-β1 Release in Fibroblast and Osteoblast-Like Cell Lines. Cells 2020; 9:E1924. [PMID: 32825091 PMCID: PMC7564311 DOI: 10.3390/cells9091924] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 08/08/2020] [Accepted: 08/18/2020] [Indexed: 12/26/2022] Open
Abstract
Wound healing constitutes an essential process for all organisms and involves a sequence of three phases. The disruption or elongation of any of these phases can lead to a chronic or non-healing wound. Electrical stimulation accelerates wound healing by mimicking the current that is generated in the skin after any injury. Here, we sought to identify the molecular mechanisms involved in the healing process following in vitro microcurrent stimulation-a type of electrotherapy. Our results concluded that microcurrents promote cell proliferation and migration in an ERK 1/2- or p38-dependent way. Furthermore, microcurrents induce the secretion of transforming growth factor-beta-1 (TGF-β1) in fibroblasts and osteoblast-like cells. Interestingly, transcriptomic analysis uncovered that microcurrents enhance the transcriptional activation of genes implicated in Hedgehog, TGF-β1 and MAPK signaling pathways. Overall, our results demonstrate that microcurrents may enhance wound closure through a combination of signal transductions, via MAPK's phosphorylation, and the transcriptional activation of specific genes involved in the healing process. These mechanisms should be further examined in vivo, in order to verify the beneficial effects of microcurrents in wound or fracture healing.
Collapse
Affiliation(s)
| | | | | | - Konstantinos Poulas
- Laboratory of Molecular Biology and Immunology, Department of Pharmacy, University of Patras, 26504 Rio, Greece; (E.K.); (Z.Z.); (A.P.)
| |
Collapse
|
16
|
Kecik K, Mitura A. Theoretical and Experimental Investigations of a Pseudo-Magnetic Levitation System for Energy Harvesting. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1623. [PMID: 32183358 PMCID: PMC7146312 DOI: 10.3390/s20061623] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 03/04/2020] [Accepted: 03/10/2020] [Indexed: 11/17/2022]
Abstract
The paper presents an analytical, numerical and experimental analysis of the special designed system for energy harvesting. The harvester system consists of two identical magnets rigidly mounted to the tube's end. Between them, a third magnet is free to magnetically levitate (pseudo-levitate) due to the proper magnet polarity. The behaviour of the harvester is significantly complicated by a electromechanical coupling. It causes resonance curves to have a distorted shape and a new solution from which the recovered energy is higher is observed. The Harmonic Balance Method (HBM) is used to approximately describe the response and stability of the mechanical and electrical systems. The analytical results are verified by a numerical path following (continuation) method and experiment test with use of a shaker. The influence of harvester parameters on the system response and energy recovery near a main resonance is studied in detail.
Collapse
Affiliation(s)
- Krzysztof Kecik
- Department of Applied Mechanics, Lublin University of Technology, 20-618 Lublin, Poland;
| | | |
Collapse
|
17
|
Teixeira M, Gouveia M, Duarte A, Ferreira M, Simões MI, Conceição M, Silva G, Magalhães S, Ferreira R, Nunes A, Vieira SI, Ribeiro F. Regular Exercise Participation Contributes to Better Proteostasis, Inflammatory Profile, and Vasoactive Profile in Patients With Hypertension. Am J Hypertens 2020; 33:119-123. [PMID: 31560738 DOI: 10.1093/ajh/hpz160] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 08/05/2019] [Accepted: 09/24/2019] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Physical exercise is a well-established strategy to control blood pressure. Nonetheless, its effects on protein homeostasis in individuals with hypertension are not clearly defined. AIMS Evaluate proteostasis, quality of life, and inflammation, oxidative stress, and vasoactive biomarkers in adults with hypertension regarding reported exercise habits. METHODS Twenty individuals were recruited in a health-care centre, 10 regular exercisers (age: 68.3 ± 4.2 years) and 10 age-matched individuals without regular exercise participation (age: 67.7 ± 5.1 years). Proteostasis and the levels of ubiquitin, heat shock protein 70 (Hsp70), endothelial nitric oxide synthase (eNOS), matrix metalloproteinases 2 (MMP-2), tissue inhibitor of MMP-2 (TIMP-2), connexin 43 (Cx43) and extracellular superoxide dismutase-3 (SOD-3) were assessed in plasma using immunoblotting techniques (western blot or slot blot) and Fourier-transform infrared spectroscopy (FTIR). Quality of life was assessed using the Short Form 36 (SF-36) version 2.0 questionnaire. RESULTS Significant higher levels of interleukin (IL)-6 (P = 0.014), eNOS (P = 0.011), Cx43 (P = 0.020), TIMP-2 (P = 0.038), and SOD-3 (P = 0.001), with a fold increase of 1.5, 1.2, 2.1, 1.3, and 1.2, respectively, were found in the exercise group. The overall quality of life (60.1 ± 4.3 vs. 53.2 ± 5.9, P = 0.009), as well as mental health domain (59.4 ± 7.9 vs. 50.7 ± 7.2, P = 0.024) were significantly higher in the exercise group. Multivariate analysis by FTIR showed that the age-matched group is characterized by peaks related with antiparallel β-sheet, whereas exercise group is characterized by peaks related to random coils, β-sheet, and α-helix. CONCLUSIONS Individuals with regular exercise participation showed better proteostasis, quality of life, inflammatory profile, antioxidant defenses, and eNOS levels.
Collapse
Affiliation(s)
- Manuel Teixeira
- Department of Medical Sciences and Institute of Biomedicine (iBiMED), University of Aveiro, Aveiro, Portugal
| | - Marisol Gouveia
- Department of Medical Sciences and Institute of Biomedicine (iBiMED), University of Aveiro, Aveiro, Portugal
| | - Ana Duarte
- Unidade Cuidados na Comunidade Cubo Mágico da Saúde, Oliveira do Bairro, Portugal
| | - Miriam Ferreira
- Unidade Cuidados na Comunidade Cubo Mágico da Saúde, Oliveira do Bairro, Portugal
| | - Maria I Simões
- Unidade Cuidados na Comunidade Cubo Mágico da Saúde, Oliveira do Bairro, Portugal
| | - Maria Conceição
- Unidade Cuidados na Comunidade Cubo Mágico da Saúde, Oliveira do Bairro, Portugal
| | - Gladys Silva
- Câmara Municipal de Oliveira do Bairro, Oliveira do Bairro, Portugal
| | - Sandra Magalhães
- Department of Medical Sciences and Institute of Biomedicine (iBiMED), University of Aveiro, Aveiro, Portugal
- Aveiro Institute of Materials (CICECO), University of Aveiro, Aveiro, Portugal
| | - Rita Ferreira
- QOPNA & LAQV, Department of Chemistry, University of Aveiro, Aveiro, Portugal
| | - Alexandra Nunes
- Department of Medical Sciences and Institute of Biomedicine (iBiMED), University of Aveiro, Aveiro, Portugal
| | - Sandra I Vieira
- Department of Medical Sciences and Institute of Biomedicine (iBiMED), University of Aveiro, Aveiro, Portugal
- The Discoveries CTR, University of Aveiro, Aveiro, Portugal
| | - Fernando Ribeiro
- School of Health Sciences and Institute of Biomedicine (iBiMED), University of Aveiro, Aveiro, Portugal
| |
Collapse
|
18
|
Slabov V, Kopyl S, Soares Dos Santos MP, Kholkin AL. Natural and Eco-Friendly Materials for Triboelectric Energy Harvesting. NANO-MICRO LETTERS 2020; 12:42. [PMID: 34138259 PMCID: PMC7770886 DOI: 10.1007/s40820-020-0373-y] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2019] [Accepted: 12/25/2019] [Indexed: 05/20/2023]
Abstract
Triboelectric nanogenerators (TENGs) are promising electric energy harvesting devices as they can produce renewable clean energy using mechanical excitations from the environment. Several designs of triboelectric energy harvesters relying on biocompatible and eco-friendly natural materials have been introduced in recent years. Their ability to provide customizable self-powering for a wide range of applications, including biomedical devices, pressure and chemical sensors, and battery charging appliances, has been demonstrated. This review summarizes major advances already achieved in the field of triboelectric energy harvesting using biocompatible and eco-friendly natural materials. A rigorous, comparative, and critical analysis of preparation and testing methods is also presented. Electric power up to 14 mW was already achieved for the dry leaf/polyvinylidene fluoride-based TENG devices. These findings highlight the potential of eco-friendly self-powering systems and demonstrate the unique properties of the plants to generate electric energy for multiple applications.
Collapse
Affiliation(s)
- Vladislav Slabov
- Department of Physics and CICECO-Aveiro Institute of Materials, University of Aveiro, 3810-193, Aveiro, Portugal
- Centre for Mechanical Technology and Automation (TEMA), University of Aveiro, 3810-193, Aveiro, Portugal
| | - Svitlana Kopyl
- Department of Physics and CICECO-Aveiro Institute of Materials, University of Aveiro, 3810-193, Aveiro, Portugal
| | - Marco P Soares Dos Santos
- Centre for Mechanical Technology and Automation (TEMA), University of Aveiro, 3810-193, Aveiro, Portugal
- Department of Mechanical Engineering, University of Aveiro, 3810-193, Aveiro, Portugal
| | - Andrei L Kholkin
- Department of Physics and CICECO-Aveiro Institute of Materials, University of Aveiro, 3810-193, Aveiro, Portugal.
- School of Natural Sciences and Mathematics, Ural Federal University, Ekaterinburg, Russia, 620000.
- Laboratory of Functional Low-Dimensional Structures, National University of Science and Technology MISiS, Moscow, Russia, 119049.
| |
Collapse
|
19
|
Cachão JH, Soares dos Santos MP, Bernardo R, Ramos A, Bader R, Ferreira JAF, Torres Marques A, Simões JAO. Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants. SENSORS 2019; 20:s20010104. [PMID: 31878028 PMCID: PMC6982938 DOI: 10.3390/s20010104] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 11/07/2019] [Accepted: 11/10/2019] [Indexed: 02/02/2023]
Abstract
Musculoskeletal disorders are becoming an ever-growing societal burden and, as a result, millions of bone replacements surgeries are performed per year worldwide. Despite total joint replacements being recognized among the most successful surgeries of the last century, implant failure rates exceeding 10% are still reported. These numbers highlight the necessity of technologies to provide an accurate monitoring of the bone–implant interface state. This study provides a detailed review of the most relevant methodologies and technologies already proposed to monitor the loosening states of endoprosthetic implants, as well as their performance and experimental validation. A total of forty-two papers describing both intracorporeal and extracorporeal technologies for cemented or cementless fixation were thoroughly analyzed. Thirty-eight technologies were identified, which are categorized into five methodologies: vibrometric, acoustic, bioelectric impedance, magnetic induction, and strain. Research efforts were mainly focused on vibrometric and acoustic technologies. Differently, approaches based on bioelectric impedance, magnetic induction and strain have been less explored. Although most technologies are noninvasive and are able to monitor different loosening stages of endoprosthetic implants, they are not able to provide effective monitoring during daily living of patients.
Collapse
Affiliation(s)
- João Henrique Cachão
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Marco P. Soares dos Santos
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
- Associated Laboratory for Energy, Transports and Aeronautics (LAETA), 4150-179 Porto, Portugal
- Correspondence:
| | - Rodrigo Bernardo
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Ramos
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| | - Rainer Bader
- Department of Orthopedics, University Medicine Rostock, 18057 Rostock, Germany
| | - Jorge A. F. Ferreira
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Torres Marques
- Associated Laboratory for Energy, Transports and Aeronautics (LAETA), 4150-179 Porto, Portugal
- Mechanical Engineering Department, University of Porto, 4200-465 Porto, Portugal
| | - José A. O. Simões
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| |
Collapse
|
20
|
Bernardo R, Rodrigues A, Soares Dos Santos MP, Carneiro P, Lopes A, Sequeira Amaral J, Sequeira Amaral V, Morais R. Novel magnetic stimulation methodology for low-current implantable medical devices. Med Eng Phys 2019; 73:77-84. [PMID: 31477429 DOI: 10.1016/j.medengphy.2019.07.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 05/10/2019] [Accepted: 07/28/2019] [Indexed: 12/15/2022]
Abstract
Recent studies highlight the ability of inductive architectures to deliver therapeutic magnetic stimuli to target tissues and to be embedded into small-scale intracorporeal medical devices. However, to date, current micro-scale biomagnetic devices require very high electric current excitations (usually exceeding 1 A) to ensure the delivery of efficient magnetic flux densities. This is a critical problem as advanced implantable devices demand self-powering, stand-alone and long-term operation. This work provides, for the first time, a novel small-scale magnetic stimulation system that requires up to 50-fold lower electric current excitations than required by relevant biomagnetic technology recently proposed. Computational models were developed to analyse the magnetic stimuli distributions and densities delivered to cellular tissues during in vitro experiments, such that the feasibility of this novel stimulator can be firstly evaluated on cell culture tests. The results demonstrate that this new stimulative technology is able to deliver osteogenic stimuli (0.1-7 mT range) by current excitations in the 0.06-4.3 mA range. Moreover, it allows coil designs with heights lower than 1 mm without significant loss of magnetic stimuli capability. Finally, suitable core diameters and stimulator-stimulator distances allow to define heterogeneity or quasi-homogeneity stimuli distributions. These results support the design of high-sophisticated biomagnetic devices for a wide range of therapeutic applications.
Collapse
Affiliation(s)
- Rodrigo Bernardo
- Department of Mechanical Engineering, University of Aveiro, Aveiro, Portugal
| | - André Rodrigues
- Department of Mechanical Engineering, University of Aveiro, Aveiro, Portugal
| | - Marco P Soares Dos Santos
- Department of Mechanical Engineering, University of Aveiro, Aveiro, Portugal; Centre for Mechanical Technology and Automation (TEMA), University of Aveiro, Aveiro, Portugal; Associated Laboratory for Energy, Transports and Aeronautics (LAETA), Portugal.
| | - Pedro Carneiro
- Department of Mechanical Engineering, University of Aveiro, Aveiro, Portugal
| | - António Lopes
- Department of Physics, University of Aveiro, Aveiro, Portugal; Aveiro Institute of Materials, Aveiro, Portugal
| | - João Sequeira Amaral
- Department of Physics, University of Aveiro, Aveiro, Portugal; Aveiro Institute of Materials, Aveiro, Portugal
| | - Vítor Sequeira Amaral
- Department of Physics, University of Aveiro, Aveiro, Portugal; Aveiro Institute of Materials, Aveiro, Portugal
| | - Raul Morais
- University of Trás-os-Montes e Alto Douro, Vila Real, Portugal; Institute for Systems and Computer Engineering, Technology and Science (INESC TEC), Porto, Portugal
| |
Collapse
|