Christierson L, Frieberg P, Lala T, Töger J, Liuba P, Revstedt J, Isaksson H, Hakacova N. Multi-Modal in Vitro Experiments Mimicking the Flow Through a Mitral Heart Valve Phantom. Cardiovasc Eng Technol 2024:10.1007/s13239-024-00732-3. [PMID: 38782878 DOI: 10.1007/s13239-024-00732-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 04/29/2024] [Indexed: 05/25/2024]
Abstract
PURPOSE Fluid-structure interaction (FSI) models are more commonly applied in medical research as computational power is increasing. However, understanding the accuracy of FSI models is crucial, especially in the context of heart valve disease in patient-specific models. Therefore, this study aimed to create a multi-modal benchmarking data set for cardiac-inspired FSI models, based on clinically important parameters, such as the pressure, velocity, and valve opening, with an in vitro phantom setup. METHOD An in vitro setup was developed with a 3D-printed phantom mimicking the left heart, including a deforming mitral valve. A range of pulsatile flows were created with a computer-controlled motor-and-pump setup. Catheter pressure measurements, magnetic resonance imaging (MRI), and echocardiography (Echo) imaging were used to measure pressure and velocity in the domain. Furthermore, the valve opening was quantified based on cine MRI and Echo images. RESULT The experimental setup, with 0.5% cycle-to-cycle variation, was successfully built and six different flow cases were investigated. Higher velocity through the mitral valve was observed for increased cardiac output. The pressure difference across the valve also followed this trend. The flow in the phantom was qualitatively assessed by the velocity profile in the ventricle and by streamlines obtained from 4D phase-contrast MRI. CONCLUSION A multi-modal set of data for validation of FSI models has been created, based on parameters relevant for diagnosis of heart valve disease. All data is publicly available for future development of computational heart valve models.
Collapse
Affiliation(s)
- Lea Christierson
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden.
- Department of Biomedical Engineering, Lund University, Lund, Sweden.
| | - Petter Frieberg
- Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden
| | - Tania Lala
- Department of Biomedical Engineering, Lund University, Lund, Sweden
- Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden
| | - Johannes Töger
- Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden
| | - Petru Liuba
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden
| | - Johan Revstedt
- Department of Energy Science, Lund University, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Nina Hakacova
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden
| |
Collapse
|
2
|
Christierson L, Frieberg P, Lala T, Töger J, Liuba P, Revstedt J, Isaksson H, Hakacova N. Validation of fluid-structure interaction simulations of the opening phase of phantom mitral heart valves under physiologically inspired conditions. Comput Biol Med 2024; 171:108033. [PMID: 38430739 DOI: 10.1016/j.compbiomed.2024.108033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 12/22/2023] [Accepted: 01/26/2024] [Indexed: 03/05/2024]
Abstract
BACKGROUND AND OBJECTIVE Atrioventricular valve disease is a common cause of heart failure, and successful surgical or interventional outcomes are crucial. Patient-specific fluid-structure interaction (FSI) modeling may provide valuable insights into valve dynamics and guidance of valve repair strategies. However, lack of validation has kept FSI modeling from clinical implementation. Therefore, this study aims to validate FSI simulations against in vitro benchmarking data, based on clinically relevant parameters for evaluating heart valve disease. METHODS An FSI model that mimics the left heart was developed. The domain included a deformable mitral valve of different stiffnesses run with different inlet velocities. Five different cases were simulated and compared to in vitro data based on the pressure difference across the valve, the valve opening, and the velocity in the flow domain. RESULTS The simulations underestimate the pressure difference across the valve by 6.8-14 % compared to catheter measurements. Evaluation of the valve opening showed an underprediction of 5.4-7.3 % when compared to cine MRI, 2D Echo, and 3D Echo data. Additionally, the simulated velocity through the valve showed a 7.9-8.4 % underprediction in relation to Doppler Echo measurements. Qualitative assessment of the velocity profile in the ventricle and the streamlines of the flow in the domain showed good agreement of the flow behavior. CONCLUSIONS Parameters relevant to the diagnosis of heart valve disease estimated by FSI simulations showed good agreement when compared to in vitro benchmarking data, with differences small enough not to affect the grading of heart valve disease. The FSI model is thus deemed good enough for further development toward patient-specific cases.
Collapse
Affiliation(s)
- Lea Christierson
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden. Address: Barnhjärtcentrum mottagning, Skånes universitetssjukhus, Lasarettsgatan 48, 221 85, Lund, Sweden; Department of Biomedical Engineering, Lund University, Lund, Sweden. Address: Box 118, 221 00, Lund, Sweden.
| | - Petter Frieberg
- Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden. Address: Box 177, 221 00, Lund, Sweden
| | - Tania Lala
- Department of Biomedical Engineering, Lund University, Lund, Sweden. Address: Box 118, 221 00, Lund, Sweden; Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden. Address: Box 177, 221 00, Lund, Sweden
| | - Johannes Töger
- Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden. Address: Box 177, 221 00, Lund, Sweden
| | - Petru Liuba
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden. Address: Barnhjärtcentrum mottagning, Skånes universitetssjukhus, Lasarettsgatan 48, 221 85, Lund, Sweden
| | - Johan Revstedt
- Department of Energy Science, Lund University, Lund, Sweden. Address: Box 118, 221 00, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden. Address: Box 118, 221 00, Lund, Sweden
| | - Nina Hakacova
- Department of Clinical Sciences Lund, Pediatric Heart Center, Skåne University Hospital, Lund University, Lund, Sweden. Address: Barnhjärtcentrum mottagning, Skånes universitetssjukhus, Lasarettsgatan 48, 221 85, Lund, Sweden
| |
Collapse
|
3
|
Khalili O, Asgari M. Fluid-structure interaction and structural simulation of high acceleration effects on surgical repaired human mitral valve biomechanics. Proc Inst Mech Eng H 2023; 237:1248-1260. [PMID: 37846647 DOI: 10.1177/09544119231200367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
Mitral valve dynamics depend on force stability in the mitral leaflets, the mitral annulus, the chordae tendineae, and the papillary muscles. In chordal rupture conditions, the proper function of the valve disrupts, causing mitral regurgitation, the most prevalent valvular disease. In this study, Structural and FSI frameworks were employed to study valve dynamics in healthy, pathologic, and repaired states. Anisotropic, non-linear, hyper-elastic material properties applied to tissues of the valve while the first-order Ogden model reflected the best compatibility with the empirical data. Hemodynamic blood pressure of the cardiovascular system is applied on the leaflets as uniform loads varying by time, and exposure to high acceleration loads imposed on models. Immersed boundary method used for simulation of fluid in a cardiac cycle. In comparison between healthy and pathologic models, stress values and chordal tensions are increased, by nearly threefold and twofold, respectively. Stress concentration on leaflets is reduced by 75% after performing a successful surgical repair on the pathological model. Crash acceleration loads led to more significant stress and chordae tension on models, by 27% and 23%, respectively. It is concluded that a more sophisticated model could lead to a better understanding of human heart valve biomechanics in various conditions. If a preoperative plan is developed based on these modeling methods, the requirement for multiple successive repairs would be eliminated, operative times are shortened, and patient outcomes are improved.
Collapse
Affiliation(s)
- Omid Khalili
- Faculty of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| | - Masoud Asgari
- Faculty of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| |
Collapse
|
4
|
Cai L, Hao Y, Ma P, Zhu G, Luo X, Gao H. Fluid-structure interaction simulation of calcified aortic valve stenosis. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2022; 19:13172-13192. [PMID: 36654041 DOI: 10.3934/mbe.2022616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Calcified aortic valve stenosis (CAVS) is caused by calcium buildup and tissue thickening that impede the blood flow from left ventricle (LV) to aorta. In recent years, CAVS has become one of the most common cardiovascular diseases. Therefore, it is necessary to study the mechanics of aortic valve (AV) caused by calcification. In this paper, based on a previous idealized AV model, the hybrid immersed boundary/finite element method (IB/FE) is used to study AV dynamics and hemodynamic performance under normal and calcified conditions. The computational CAVS model is realized by dividing the AV leaflets into a calcified region and a healthy region, and each is described by a specific constitutive equation. Our results show that calcification can significantly affect AV dynamics. For example, the elasticity and mobility of the leaflets decrease due to calcification, leading to a smaller opening area with a high forward jet flow across the valve. The calcified valve also experiences an increase in local stress and strain. The increased loading due to AV stenosis further leads to a significant increase in left ventricular energy loss and transvalvular pressure gradients. The model predicted hemodynamic parameters are in general consistent with the risk classification of AV stenosis in the clinic. Therefore, mathematical models of AV with calcification have the potential to deepen our understanding of AV stenosis-induced ventricular dysfunction and facilitate the development of computational engineering-assisted medical diagnosis in AV related diseases.
Collapse
Affiliation(s)
- Li Cai
- School of Mathematics and Statistics, Northwestern Polytechnical University, Xi'an 710129, China
- NPU-UoG International Cooperative Lab for Computation and Application in Cardiology, Xi'an 710129, China
- Xi'an Key Laboratory of Scientific Computation and Applied Statistics, Xi'an 710129, China
| | - Yu Hao
- School of Mathematics and Statistics, Northwestern Polytechnical University, Xi'an 710129, China
- NPU-UoG International Cooperative Lab for Computation and Application in Cardiology, Xi'an 710129, China
- Xi'an Key Laboratory of Scientific Computation and Applied Statistics, Xi'an 710129, China
| | - Pengfei Ma
- School of Mathematics and Statistics, Northwestern Polytechnical University, Xi'an 710129, China
- NPU-UoG International Cooperative Lab for Computation and Application in Cardiology, Xi'an 710129, China
- Xi'an Key Laboratory of Scientific Computation and Applied Statistics, Xi'an 710129, China
| | - Guangyu Zhu
- School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xiaoyu Luo
- School of Mathematics and Statistics, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Hao Gao
- School of Mathematics and Statistics, University of Glasgow, Glasgow, G12 8QQ, UK
| |
Collapse
|
5
|
Rivera E, Canales C, Pacheco M, García-Herrera C, Macías D, Celentano DJ, Herrera EA. Biomechanical characterization of the passive response of the thoracic aorta in chronic hypoxic newborn lambs using an evolutionary strategy. Sci Rep 2021; 11:13875. [PMID: 34230509 PMCID: PMC8260639 DOI: 10.1038/s41598-021-93267-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 06/22/2021] [Indexed: 11/22/2022] Open
Abstract
The present study involves experiments and modelling aimed at characterizing the passive structural mechanical behavior of the chronic hypoxic lamb thoracic aorta, whose gestation, birth and postnatal period were carried at high altitude (3600 masl). To this end, the mechanical response was studied via tensile and pressurization tests. The tensile and pressurization tests measurements were used simultaneously to calibrate the material parameters of the Gasser-Holzapfel-Ogden (GHO) hyperelasctic anisotropic constitutive model through an analytical-numerical optimization procedure solved with an evolutionary strategy that guarantees a stable response of the model. The model and procedure of calibration adequately adjust to the material behavior in a wide deformation range with an appropriate physical description. The results of this study predict the mechanical response of the lamb thoracic aorta under generalized loading states like those that can occur in physiological conditions and/or in systemic arterial hypertension. Finally, the novel use of the evolutionary strategy, together with the set of experiments and tools used in this study, provide a robust alternative to validate biomechanical characterizations.
Collapse
Affiliation(s)
- Eugenio Rivera
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile (USACH), Av. Bernardo O'Higgins 3363, Santiago de Chile, Chile.
| | - Claudio Canales
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile (USACH), Av. Bernardo O'Higgins 3363, Santiago de Chile, Chile
| | - Matías Pacheco
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile (USACH), Av. Bernardo O'Higgins 3363, Santiago de Chile, Chile
| | - Claudio García-Herrera
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile (USACH), Av. Bernardo O'Higgins 3363, Santiago de Chile, Chile
| | - Demetrio Macías
- ICD, P2MN, L2n, Université de Technologie de Troyes, ERL 7004, CNRS, Troyes, France
| | - Diego J Celentano
- Departamento de Ingeniería Mecánica y Metalúrgica, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Santiago de Chile, Chile
| | - Emilio A Herrera
- Laboratorio de Función y Reactividad Vascular, Programa de Fisiopatología, ICBM, Universidad de Chile, Av. Salvador 486, Santiago de Chile, Chile
| |
Collapse
|
6
|
Cai L, Zhang R, Li Y, Zhu G, Ma X, Wang Y, Luo X, Gao H. The Comparison of Different Constitutive Laws and Fiber Architectures for the Aortic Valve on Fluid-Structure Interaction Simulation. Front Physiol 2021; 12:682893. [PMID: 34248670 PMCID: PMC8266211 DOI: 10.3389/fphys.2021.682893] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 04/27/2021] [Indexed: 12/15/2022] Open
Abstract
Built on the hybrid immersed boundary/finite element (IB/FE) method, fluid-structure interaction (FSI) simulations of aortic valve (AV) dynamics are performed with three different constitutive laws and two different fiber architectures for the AV leaflets. An idealized AV model is used and mounted in a straight tube, and a three-element Windkessel model is further attached to the aorta. After obtaining ex vivo biaxial tensile testing of porcine AV leaflets, we first determine the constitutive parameters of the selected three constitutive laws by matching the analytical stretch-stress relations derived from constitutive laws to the experimentally measured data. Both the average error and relevant R-squared value reveal that the anisotropic non-linear constitutive law with exponential terms for both the fiber and cross-fiber directions could be more suitable for characterizing the mechanical behaviors of the AV leaflets. We then thoroughly compare the simulation results from both structural mechanics and hemodynamics. Compared to the other two constitutive laws, the anisotropic non-linear constitutive law with exponential terms for both the fiber and cross-fiber directions shows the larger leaflet displacements at the opened state, the largest forward jet flow, the smaller regurgitant flow. We further analyze hemodynamic parameters of the six different cases, including the regurgitant fraction, the mean transvalvular pressure gradient, the effective orifice area, and the energy loss of the left ventricle. We find that the fiber architecture with body-fitted orientation shows better dynamic behaviors in the leaflets, especially with the constitutive law using exponential terms for both the fiber and cross-fiber directions. In conclusion, both constitutive laws and fiber architectures can affect AV dynamics. Our results further suggest that the strain energy function with exponential terms for both the fiber and cross-fiber directions could be more suitable for describing the AV leaflet mechanical behaviors. Future experimental studies are needed to identify competent constitutive laws for the AV leaflets and their associated fiber orientations with controlled experiments. Although limitations exist in the present AV model, our results provide important information for selecting appropriate constitutive laws and fiber architectures when modeling AV dynamics.
Collapse
Affiliation(s)
- Li Cai
- NPU-UoG International Cooperative Lab for Computation and Application in Cardiology, Northwestern Polytechnical University, Xi'an, China
- Xi'an Key Laboratory of Scientific Computation and Applied Statistics, Xi'an, China
| | - Ruihang Zhang
- NPU-UoG International Cooperative Lab for Computation and Application in Cardiology, Northwestern Polytechnical University, Xi'an, China
| | - Yiqiang Li
- NPU-UoG International Cooperative Lab for Computation and Application in Cardiology, Northwestern Polytechnical University, Xi'an, China
| | - Guangyu Zhu
- School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Xingshuang Ma
- College of Bioengineering, Chongqing University, Chongqing, China
| | - Yongheng Wang
- NPU-UoG International Cooperative Lab for Computation and Application in Cardiology, Northwestern Polytechnical University, Xi'an, China
| | - Xiaoyu Luo
- School of Mathematics and Statistics, University of Glasgow, Glasgow, United Kingdom
| | - Hao Gao
- School of Mathematics and Statistics, University of Glasgow, Glasgow, United Kingdom
| |
Collapse
|
7
|
An image-based computational hemodynamics study of the Systolic Anterior Motion of the mitral valve. Comput Biol Med 2020; 123:103922. [PMID: 32741752 DOI: 10.1016/j.compbiomed.2020.103922] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 07/15/2020] [Accepted: 07/17/2020] [Indexed: 01/23/2023]
Abstract
Systolic Anterior Motion (SAM) of the mitral valve - often associated with Hypertrophic Obstructive Cardiomyopathy (HOCM) - is a cardiac pathology in which a functional subaortic stenosis is induced during systole by the mitral leaflets partially obstructing the outflow tract of the left ventricle. Its assessment by diagnostic tests is often difficult, possibly underestimating its severity and thus increasing the risk of heart failure. In this paper, we propose a new computational pipeline, based on cardiac cine Magnetic Resonance Imaging (cine-MRI) data, for the assessment of SAM. The pipeline encompasses image processing of the left ventricle and the mitral valve, and numerical investigation of cardiac hemodynamics by means of Computational Fluid Dynamics (CFD) in a moving domain with image-based prescribed displacement. Patient-specific geometry and motion of the left ventricle are considered in view of an Arbitrary Lagrangian-Eulerian approach for CFD, while the reconstructed mitral valve is immersed in the computational domain by means of a resistive method. We assess clinically relevant flow and pressure indicators in a parametric study for different degrees of SAM severity, in order to provide a better quantitative evaluation of the pathological condition. Moreover, we provide specific indications for its possible surgical treatment, i.e. septal myectomy.
Collapse
|
8
|
Jeong D, Li Y, Kim S, Choi Y, Lee C, Kim J. Mathematical modeling and computer simulation of the three-dimensional pattern formation of honeycombs. Sci Rep 2019; 9:20364. [PMID: 31889154 PMCID: PMC6937337 DOI: 10.1038/s41598-019-56942-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Accepted: 12/19/2019] [Indexed: 11/09/2022] Open
Abstract
We present a mathematical model, a numerical scheme, and computer simulations of the three-dimensional pattern formation of a honeycomb structure by using the immersed boundary method. In our model, we assume that initially the honeycomb cells have a hollow hemisphere mounted by a hollow circular cylinder shape at their birth and there is force acting upon the entire side of the cell. The net force from the individual cells is a key factor in their transformation from a hollow hemisphere mounted by a hollow circular cylinder shape to a rounded rhombohedral surfaces mounted by a hexagonal cylinder shape. Numerical simulations of the proposed mathematical model equation produce the rounded rhombohedral surfaces mounted by a hexagonal cylinder patterns observed in honeybee colonies.
Collapse
Affiliation(s)
- Darae Jeong
- Department of Mathematics, Kangwon National University, Gangwon-do, 24341, Republic of Korea
| | - Yibao Li
- School of Mathematics and Statistics, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Sangkwon Kim
- Department of Mathematics, Korea University, Seoul, 02841, Republic of Korea
| | - Yongho Choi
- Department of Mathematics and Big Data, Daegu University, Gyeongsan-si, Gyeongsangbuk-do, 38453, Republic of Korea
| | - Chaeyoung Lee
- Department of Mathematics, Korea University, Seoul, 02841, Republic of Korea
| | - Junseok Kim
- Department of Mathematics, Korea University, Seoul, 02841, Republic of Korea.
| |
Collapse
|