1
|
Hua B, Yang G, An Y, Lou K, Chen J, Quan G, Yuan T. Clinical and Imaging Characteristics of Contrast-enhanced Mammography and MRI to Distinguish Microinvasive Carcinoma from Ductal Carcinoma In situ. Acad Radiol 2024:S1076-6332(24)00258-7. [PMID: 38734581 DOI: 10.1016/j.acra.2024.04.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 04/14/2024] [Accepted: 04/24/2024] [Indexed: 05/13/2024]
Abstract
RATIONALE AND OBJECTIVES The prognosis of ductal carcinoma in situ with microinvasion (DCISM) is more similar to that of small invasive ductal carcinoma (IDC) than to pure ductal carcinoma in situ (DCIS). It is particularly important to accurately distinguish between DCISM and DCIS. The present study aims to compare the clinical and imaging characteristics of contrast-enhanced mammography (CEM) and magnetic resonance imaging (MRI) between DCISM and pure DCIS, and to identify predictive factors of microinvasive carcinoma, which may contribute to a comprehensive understanding of DCISM in clinical diagnosis and support surveillance strategies, such as surgery, radiation, and other treatment decisions. MATERIALS AND METHODS Forty-seven female patients diagnosed with DCIS were included in the study from May 2019 to August 2023. Patients were further divided into two groups based on pathological diagnosis: DCIS and DCISM. Clinical and imaging characteristics of these two groups were analyzed statistically. The independent clinical risk factors were selected using multivariate logistic regression and used to establish the logistic model [Logit(P)]. The diagnostic performance of independent predictors was assessed and compared using receiver operating characteristic (ROC) analysis and DeLong's test. RESULTS In CEM, the maximum cross-sectional area (CSAmax), the percentage signal difference between the enhancing lesion and background in the craniocaudal and mediolateral oblique projection (%RSCC, and %RSMLO) were found to be significantly higher for DCISM compared to DCIS (p = 0.001; p < 0.001; p = 0.008). Additionally, there were noticeable statistical differences in the patterns of enhancement morphological distribution (EMD) and internal enhancement pattern (IEP) between DCIS and DCISM (p = 0.047; p = 0.008). In MRI, only CSAmax (p = 0.012) and IEP (p = 0.020) showed significant statistical differences. The multivariate regression analysis suggested that CSAmax (in CEM or MR) and %RSCC were independent predictors of DCISM (all p < 0.05). The area under the curve (AUC) of CSAmax (CEM), %RSCC (CEM), Logit(P) (CEM), and CSAmax (MR) were 0.764, 0.795, 0.842, and 0.739, respectively. There were no significant differences in DeLong's test for these values (all p > 0.10). DCISM was significantly associated with high nuclear grade, comedo type, high axillary lymph node (ALN) metastasis, and high Ki-67 positivity compared to DCIS (all p < 0.05). CONCLUSION The tumor size (CSAmax), enhancement index (%RS), and internal enhancement pattern (IEP) were highly indicative of DCISM. DCISM tends to express more aggressive pathological features, such as high nuclear grade, comedo-type necrosis, ALN metastasis, and Ki-67 overexpression. As with MRI, CEM has the capability to help predict when DCISM is accompanying DCIS.
Collapse
Affiliation(s)
- Bei Hua
- Department of Radiology and Nuclear Medicine, The First Affiliated Hospital of Hebei Medical University, No.89 Donggang road, Shijiazhuang, Hebei, China
| | - Guang Yang
- Radiology Department, The Fourth Affiliated Hospital of Hebei Medical University, No.12 Jiankang road, Shijiazhuang, Hebei, China
| | - Yi An
- Department of Medical Service Division, The Fourth Affiliated Hospital of Hebei Medical University, No.12 Jiankang road, Shijiazhuang, Hebei, China
| | - Ke Lou
- Radiology Department, The Fourth Affiliated Hospital of Hebei Medical University, No.12 Jiankang road, Shijiazhuang, Hebei, China
| | - Jun Chen
- Radiology Department, The Fourth Affiliated Hospital of Hebei Medical University, No.12 Jiankang road, Shijiazhuang, Hebei, China.
| | - Guanmin Quan
- Department of Medical imaging, The Second Hospital of Hebei Medical University, No.215 Heping West road, Shijiazhuang, Hebei, China
| | - Tao Yuan
- Department of Medical imaging, The Second Hospital of Hebei Medical University, No.215 Heping West road, Shijiazhuang, Hebei, China
| |
Collapse
|
2
|
Lin S, Li H, Li Y, Chen Q, Ye J, Lin S, Cai S, Sun J. Diagnostic performance of contrast-enhanced mammography for suspicious findings in dense breasts: A systematic review and meta-analysis. Cancer Med 2024; 13:e7128. [PMID: 38659408 PMCID: PMC11043676 DOI: 10.1002/cam4.7128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 03/06/2024] [Accepted: 03/12/2024] [Indexed: 04/26/2024] Open
Abstract
PURPOSE Contrast-enhanced spectral imaging (CEM) is a new mammography technique, but its diagnostic value in dense breasts is still inconclusive. We did a systematic review and meta-analysis of studies evaluating the diagnostic performance of CEM for suspicious findings in dense breasts. MATERIALS AND METHODS The PubMed, Embase, and Cochrane Library databases were searched systematically until August 6, 2023. Prospective and retrospective studies were included to evaluate the diagnostic performance of CEM for suspicious findings in dense breasts. The QUADAS-2 tool was used to evaluate the quality and risk of bias of the included studies. STATA V.16.0 and Review Manager V.5.3 were used to meta-analyze the included studies. RESULTS A total of 10 studies (827 patients, 958 lesions) were included. These 10 studies reported the diagnostic performance of CEM for the workup of suspicious lesions in patients with dense breasts. The summary sensitivity and summary specificity were 0.95 (95% CI, 0.92-0.97) and 0.81 (95% CI, 0.70-0.89), respectively. Enhanced lesions, circumscribed margins, and malignancy were statistically correlated. The relative malignancy OR value of the enhanced lesions was 28.11 (95% CI, 6.84-115.48). The relative malignancy OR value of circumscribed margins was 0.17 (95% CI, 0.07-0.45). CONCLUSION CEM has high diagnostic performance in the workup of suspicious findings in dense breasts, and when lesions are enhanced and have irregular margins, they are often malignant.
Collapse
Affiliation(s)
- Shu‐ting Lin
- Department of RadiologyThe Second Affiliated Hospital of Fujian Medical UniversityQuanzhouFujianChina
| | - Hong‐jiang Li
- Department of RadiologyThe Second Affiliated Hospital of Fujian Medical UniversityQuanzhouFujianChina
| | - Yi‐zhong Li
- Department of BoneThe Second Affiliated Hospital of Fujian Medical UniversityQuanzhouFujianChina
| | - Qian‐qian Chen
- Department of RadiologyThe Second Affiliated Hospital of Fujian Medical UniversityQuanzhouFujianChina
| | - Jia‐yi Ye
- Department of RadiologyThe Second Affiliated Hospital of Fujian Medical UniversityQuanzhouFujianChina
| | - Shu Lin
- Center of Neurological and Metabolic ResearchThe Second Affiliated Hospital of Fujian Medical UniversityQuanzhouFujianChina
- Department of Neuroendocrinology, Group of NeuroendocrinologyGarvan Institute of Medical ResearchSydneyNew South WalesAustralia
| | - Si‐qing Cai
- Department of RadiologyThe Second Affiliated Hospital of Fujian Medical UniversityQuanzhouFujianChina
| | - Jian‐guo Sun
- Department of Urinary SurgeryThe Second Affiliated Hospital of Fujian Medical UniversityQuanzhouFujianChina
| |
Collapse
|
3
|
Hafez MAF, Zeinhom A, Hamed DAA, Ghaly GRM, Tadros SFK. Contrast-enhanced mammography versus breast MRI in the assessment of multifocal and multicentric breast cancer: a retrospective study. Acta Radiol 2023; 64:2868-2880. [PMID: 37674355 DOI: 10.1177/02841851231198346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
BACKGROUND Breast cancer multifocality and multicentricity diagnosis influences the surgeon's choice between applying breast conservative therapy or performing mastectomy. PURPOSE To assess the role of contrast enhanced mammography (CEM) and breast magnetic resonance imaging (MRI) in the assessment of preoperative breast cancer multifocality and multicentricity and to assess their accuracy, agreement and impact on the surgical management. MATERIAL AND METHODS The study retrospectively included cases over a 5-year period. After analysis and interpretation of suspicious breast lesions, a comparative evaluation of CEM and MRI was conducted with the assessment of diagnostic indices, including sensitivity, specificity and diagnostic accuracy. The kappa (κ) measure of agreement between both modalities was measured. The postoperative specimen pathology was the reference standard. RESULTS One hundred and twenty-two female cases with 126 breast lesions were evaluated. Specimen pathology, MRI and CEM showed a single neoplastic lesion in 67.5%, 35% and 48.5% of cases, respectively, and multiple neoplastic lesions in 32.5%, 65% and 51.6% of cases, respectively. The sensitivity, specificity and accuracy of MRI were 95.12%, 49.41%,and 64.29%, and the CEM values were 85.37%, 64.71% and 71.43%, respectively. The κ value was 0.592 with an intermediate agreement between both modalities. When comparing between both modalities, enhancing foci showed a statistically significant difference, although there were no statistically significant difference in terms of high breast density or molecular subtype. CONCLUSION In terms of breast cancer multifocality and multicentricity evaluation, MRI showed a higher sensitivity, while CEM showed a higher specificity, and there was moderate agreement between the two modalities.
Collapse
Affiliation(s)
- Mona Ahmed Fouad Hafez
- Diagnostic Radiology and Intervention Department, Faculty of Medicine-Cairo University and Baheya Foundation for Early Detection & Treatment of Breast Cancer, Giza, Egypt
| | - Asmaa Zeinhom
- Baheya Foundation for Early Detection & Treatment of Breast Cancer, Giza, Egypt
| | | | - Galal Rafik Mohamed Ghaly
- National Cancer Institute, Cairo University and Baheya Foundation For Early Detection & Treatment of Breast Cancer, Giza, Egypt
| | - Sally Fouad Kamel Tadros
- Diagnostic Radiology and Intervention Department, Faculty of Medicine-Cairo University and Baheya Foundation for Early Detection & Treatment of Breast Cancer, Giza, Egypt
| |
Collapse
|
4
|
Background enhancement in contrast-enhanced spectral mammography (CESM): are there qualitative and quantitative differences between imaging systems? Eur Radiol 2023; 33:2945-2953. [PMID: 36474057 PMCID: PMC10017655 DOI: 10.1007/s00330-022-09238-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 08/15/2022] [Accepted: 10/13/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To evaluate the impact of the digital mammography imaging system on overall background enhancement on recombined contrast-enhanced spectral mammography (CESM) images, the overall background enhancement of two different mammography systems was compared. METHODS In a retrospective single-center study, CESM images of n = 129 female patients who underwent CESM between 2016 and 2019 were analyzed independently by two radiologists. Two mammography machines of different manufacturers were compared qualitatively using a Likert-scale from 1 (minimal) to 4 (marked overall background enhancement) and quantitatively by placing a region of interest and measuring the intensity enhancement. Lesion conspicuity was analyzed using a Likert-scale from 1 (lesion not reliably distinguishable) to 5 (excellent lesion conspicuity). A multivariate regression was performed to test for potential biases on the quantitative results. RESULTS Significant differences in qualitative background enhancement measurements between machines A and B were observed for both readers (p = 0.003 and p < 0.001). The quantitative evaluation showed significant differences in background enhancement with an average difference of 75.69 (99%-CI [74.37, 77.02]; p < 0.001). Lesion conspicuity was better for machine A for the first and second reader respectively (p = 0.009 and p < 0.001). The factor machine was the only influencing factor (p < 0.001). The factors contrast agent, breast density, age, and menstrual cycle could be excluded as potential biases. CONCLUSION Mammography machines seem to significantly influence overall background enhancement qualitatively and quantitatively; thus, an impact on diagnostic accuracy appears possible. KEY POINTS • Overall background enhancement on CESM differs between different vendors qualitatively and quantitatively. • Our retrospective single-center study showed consistent results of the qualitative and quantitative data analysis of overall background enhancement. • Lesion conspicuity is higher in cases of lower background enhancement on CESM.
Collapse
|
5
|
Rong X, Kang Y, Xue J, Han P, Guang Y, Li Z. Contrast-enhanced spectral mammography: are kinetic patterns useful for differential diagnoses of enhanced lesions? Diagn Interv Radiol 2023; 29:244-250. [PMID: 36987842 PMCID: PMC10679705 DOI: 10.5152/dir.2022.21562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 12/27/2021] [Indexed: 01/15/2023]
Abstract
PURPOSE To investigate the diagnostic efficiency of the kinetic curves of enhanced lesions on contrast-en-hanced spectral mammography (CESM) and whether they were similar to those of magnetic resonance imaging (MRI). METHODS Two hundred and twelve patients with 222 enhanced lesions were included in this prospective study. Single-view craniocaudal of an affected breast was acquired at 3, 5, and 7 min after contrast media injection. The kinetic patterns of each lesion were evaluated and classified as elevated (type I), steady (type II), and depressed (type III). Statistical comparison used the chi-squared test, the receiver operating characteristic (ROC) curve, and Cohen's kappa. RESULTS Of 222 enhanced lesions, 140 were breast cancers, and 82 were benign lesions. The distribution of the kinetic curves for breast cancer was type I, 3.57%, type II, 35.71%, and type III, 60.72%. As for benign lesions, the distribution was type I, 43.90%, type II, 45.12%, and type III, 10.98%. The difference in the enhancement patterns between benign lesions and breast cancers was significant (P < 0.001). The likelihood of breast cancer related to a type I, II, and III curve was 12.20%, 57.47%, and 90.43%, respectively. For the enhancement intensity, the area under curve (AUC) of the ROC curves was 0.702 ± 0.036; for enhancement patterns, the AUC increased to 0.819 ± 0.030. Cohen's kappa coefficient was 0.752 (P < 0.001) regarding the kinetic curves for CESM and MRI. CONCLUSION The kinetic patterns on CESM show promise in differentiating between benign lesions and breast cancers, with good agreement, when compared with MRI.
Collapse
Affiliation(s)
- Xiaocui Rong
- Department of Radiology, Hebei Medical University Fourth Affiliated Hospital, Shijiazhuang, China
| | - Yihe Kang
- Department of Radiology, Hebei Medical University Fourth Affiliated Hospital, Shijiazhuang, China
| | - Jing Xue
- Department of Radiology, Hebei Medical University Fourth Affiliated Hospital, Shijiazhuang, China
| | - Pengyin Han
- Department of Radiology, Hebei Medical University Fourth Affiliated Hospital, Shijiazhuang, China
| | - Yang Guang
- Department of Radiology, Hebei Medical University Fourth Affiliated Hospital, Shijiazhuang, China
| | - Zhigang Li
- Department of Radiology, Hebei Medical University Fourth Affiliated Hospital, Shijiazhuang, China
| |
Collapse
|
6
|
Migliaro G, Bicchierai G, Valente P, Di Naro F, De Benedetto D, Amato F, Boeri C, Vanzi E, Miele V, Nori J. Contrast Enhanced Mammography (CEM) Enhancing Asymmetry: Single-Center First Case Analysis. Diagnostics (Basel) 2023; 13:diagnostics13061011. [PMID: 36980319 PMCID: PMC10047777 DOI: 10.3390/diagnostics13061011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 02/02/2023] [Accepted: 03/04/2023] [Indexed: 03/09/2023] Open
Abstract
(1) Purpose: The latest Breast Imaging Reporting and Data System (BI-RADS) lexicon for CEM introduced a new descriptor, enhancing asymmetries (EAs). The purpose of this study was to determine which types of lesions were correlated with EAs. (2) Methods: A total of 3359 CEM exams, executed at AOUC Careggi in Florence, Italy between 2019 and 2021 were retrospectively assessed by two radiologists. For each of the EAs found, the size, the enhancing conspicuity (degree of enhancement relative to background described as low, moderate, or high), whether there was a corresponding finding in the traditional radiology images (US or mammography), the biopsy results when performed including any follow-up exams, and the presence of background parenchymal enhancement (BPE) of the normal breast tissue (minimal, mild, moderate, marked) were described. (3) Results: A total of 64 women were included, 36 of them underwent CEM for a preoperative staging assessment, and 28 for a problem-solving examination. Among the 64 EAs, 19/64 (29.69%) resulted in being category B5 (B5) lesions, 5/64 (7.81%) as category B3 (B3) lesions, and 40/64(62.50%) were negative or benign either after biopsy or second-look exams or follow-up. We assessed that EAs with higher enhancing conspicuity correlated significantly with a higher risk of B5 lesions (p: 0.0071), especially bigger ones (p: 0.0274). Conclusions: EAs can relate both with benign and tumoral lesions, and they need to be assessed as the other CEM descriptors, with re-evaluation of low-energy images and second-look exams, particularly larger EAs with higher enhancing conspicuity.
Collapse
Affiliation(s)
- Giuliano Migliaro
- Breast Imaging Diagnostic Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
| | - Giulia Bicchierai
- Breast Imaging Diagnostic Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
- Correspondence:
| | - Pietro Valente
- Breast Imaging Diagnostic Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
| | - Federica Di Naro
- Breast Imaging Diagnostic Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
| | - Diego De Benedetto
- Breast Imaging Diagnostic Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
| | - Francesco Amato
- Breast Imaging Diagnostic Unit, Radiology Department, Ospedale San Giovanni di Dio, 92100 Agrigento, Italy
| | - Cecilia Boeri
- Breast Imaging Diagnostic Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
| | - Ermanno Vanzi
- Breast Imaging Diagnostic Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
| | - Vittorio Miele
- Department of Radiology, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
| | - Jacopo Nori
- Breast Imaging Diagnostic Unit, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy
| |
Collapse
|
7
|
Cain N, Rahbar G, Park E, Tang M, Andrews-Tang D, Gupta E, Roth A, Lee-Felker S, Thomas M. Quantitative Analysis of Contrast-enhanced Mammography for Risk Stratification of Benign Versus Malignant Disease and Molecular Subtype. JOURNAL OF BREAST IMAGING 2022; 4:496-505. [PMID: 38416945 DOI: 10.1093/jbi/wbac044] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Indexed: 03/01/2024]
Abstract
OBJECTIVE To assess quantitative enhancement of benign, high-risk, and malignant lesions and differences in molecular subtype and grade of malignant lesions on contrast-enhanced mammography (CEM). METHODS This IRB-approved retrospective study included women who underwent CEM for diagnostic work-up of a breast lesion between 2014 and 2020. Inclusion criteria were women who had diagnostic work-up with CEM and had BI-RADS 1 or 2 with one year follow-up, BI-RADS 3 with tissue diagnosis or stability for 2 years, or BI-RADS 4 or 5 with tissue diagnosis. An enhancement ratio was calculated for all lesions. This was obtained by drawing a region of interest within the lesion and a second region of interest in the nonenhancing background tissue using a program developed with MATLAB. Descriptive statistics were evaluated using chi-squared tests, Fisher exact tests, and analysis of variance. A logistic regression model was used to predict cancer outcome using the enhancement ratio. Statistical significance was defined as P < 0.05. RESULTS There were 332 lesions in 210 women that met study criteria. Of the 332 lesions, 50.9% (169/332) were malignant, 5.7% (19/332) were high-risk, and 43.4% (144/332) were benign. Enhancement intensity of malignant lesions was higher than benign lesions. Odds ratio for quantitative enhancement of malignant lesions was 30.15 (P < 0.0001). Enhancement ratio above 1.49 had an 84.0% sensitivity and 84.0% specificity for malignancy. HER2-enriched breast cancers had significantly higher mean enhancement ratios (P = 0.0062). CONCLUSION Quantitative enhancement on CEM demonstrated that malignant breast lesions had higher mean enhancement intensity than benign lesions.
Collapse
Affiliation(s)
- Natalie Cain
- Ronald Reagan-UCLA Medical Center, Department of Radiology, Los Angeles, CA, USA
| | - Guita Rahbar
- Olive View-UCLA Medical Center, Department of Radiology, Sylmar, CA, USA
| | - Esther Park
- Allegheny Health Network, Department of Radiology, Pittsburgh, PA, USA
| | - Maxine Tang
- University of Chicago Medical Center, Department of Medicine, Chicago, IL, USA
| | | | - Esha Gupta
- Olive View-UCLA Medical Center, Department of Radiology, Sylmar, CA, USA
| | - Antoinette Roth
- Olive View-UCLA Medical Center, Department of Radiology, Sylmar, CA, USA
| | - Stephanie Lee-Felker
- Ronald Reagan-UCLA Medical Center, Department of Radiology, Los Angeles, CA, USA
| | - Mariam Thomas
- Olive View-UCLA Medical Center, Department of Radiology, Sylmar, CA, USA
| |
Collapse
|
8
|
Nicosia L, Bozzini AC, Palma S, Montesano M, Pesapane F, Ferrari F, Dominelli V, Rotili A, Meneghetti L, Frassoni S, Bagnardi V, Sangalli C, Cassano E. A Score to Predict the Malignancy of a Breast Lesion Based on Different Contrast Enhancement Patterns in Contrast-Enhanced Spectral Mammography. Cancers (Basel) 2022; 14:cancers14174337. [PMID: 36077871 PMCID: PMC9455061 DOI: 10.3390/cancers14174337] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/29/2022] [Accepted: 09/02/2022] [Indexed: 11/17/2022] Open
Abstract
Background: To create a predictive score of malignancy of a breast lesion based on the main contrast enhancement features ascertained by contrast-enhanced spectral mammography (CESM). Methods: In this single-centre prospective study, patients with suspicious breast lesions (BIRADS > 3) were enrolled between January 2013 and February 2022. All participants underwent CESM prior to breast biopsy, and eventually surgery. A radiologist with 20 years’ experience in breast imaging evaluated the presence or absence of enhancement and the following enhancement descriptors: intensity, pattern, margin, and ground glass. A score of 0 or 1 was given for each descriptor, depending on whether the enhancement characteristic was predictive of benignity or malignancy (both in situ and invasive). Then, an overall enhancement score ranging from 0 to 4 was obtained. The histological results were considered the gold standard in the evaluation of the relationship between enhancement patterns and malignancy. Results: A total of 321 women (median age: 51 years; range: 22−83) with 377 suspicious breast lesions were evaluated. Two hundred forty-nine lesions (66%) have malignant histological results (217 invasive and 32 in situ). Considering an overall enhancement score ≥ 2 as predictive of malignancy, we obtain an overall sensitivity of 92.4%; specificity of 89.8%; positive predictive value of 94.7%; and negative predictive value of 85.8%. Conclusions: Our proposed predictive score on the enhancement descriptors of CESM to predict the malignancy of a breast lesion shows excellent results and can help in early breast cancer diagnosis and in avoiding unnecessary biopsies.
Collapse
Affiliation(s)
- Luca Nicosia
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
- Correspondence:
| | - Anna Carla Bozzini
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
| | - Simone Palma
- University Department of Radiological and Hematological Sciences, Catholic University of the Sacred Heart, Largo Francesco Vito 1, 00168 Rome, Italy
| | - Marta Montesano
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
| | - Filippo Pesapane
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
| | - Federica Ferrari
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
| | - Valeria Dominelli
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
| | - Anna Rotili
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
| | - Lorenza Meneghetti
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
| | - Samuele Frassoni
- Department of Statistics and Quantitative Methods, University of Milan-Bicocca, 20126 Milan, Italy
| | - Vincenzo Bagnardi
- Department of Statistics and Quantitative Methods, University of Milan-Bicocca, 20126 Milan, Italy
| | - Claudia Sangalli
- Data Management, European Institute of Oncology IRCCS, 20141 Milan, Italy
| | - Enrico Cassano
- Breast Imaging Division, Radiology Department, IEO European Institute of Oncology IRCCS, 20141 Milan, Italy
| |
Collapse
|
9
|
Vasselli F, Fabi A, Ferranti FR, Barba M, Botti C, Vidiri A, Tommasin S. How Dual-Energy Contrast-Enhanced Spectral Mammography Can Provide Useful Clinical Information About Prognostic Factors in Breast Cancer Patients: A Systematic Review of Literature. Front Oncol 2022; 12:859838. [PMID: 35941874 PMCID: PMC9355886 DOI: 10.3389/fonc.2022.859838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 05/27/2022] [Indexed: 12/24/2022] Open
Abstract
Introduction In the past decade, a new technique derived from full-field digital mammography has been developed, named contrast-enhanced spectral mammography (CESM). The aim of this study was to define the association between CESM findings and usual prognostic factors, such as estrogen receptors, progesterone receptors, HER2, and Ki67, in order to offer an updated overview of the state of the art for the early differential diagnosis of breast cancer and following personalized treatments. Materials and Methods According to the PRISMA guidelines, two electronic databases (PubMed and Scopus) were investigated, using the following keywords: breast cancer AND (CESM OR contrast enhanced spectral mammography OR contrast enhanced dual energy mammography) AND (receptors OR prognostic factors OR HER2 OR progesterone OR estrogen OR Ki67). The search was concluded in August 2021. No restriction was applied to publication dates. Results We obtained 28 articles from the research in PubMed and 114 articles from Scopus. After the removal of six replicas that were counted only once, out of 136 articles, 37 articles were reviews. Eight articles alone have tackled the relation between CESM imaging and ER, PR, HER2, and Ki67. When comparing radiological characterization of the lesions obtained by either CESM or contrast-enhanced MRI, they have a similar association with the proliferation of tumoral cells, as expressed by Ki-67. In CESM-enhanced lesions, the expression was found to be 100% for ER and 77.4% for PR, while moderate or high HER2 positivity was found in lesions with non-mass enhancement and with mass closely associated with a non-mass enhancement component. Conversely, the non-enhancing breast cancer lesions were not associated with any prognostic factor, such as ER, PR, HER2, and Ki67, which may be associated with the probability of showing enhancement. Radiomics on CESM images has the potential for non-invasive characterization of potentially heterogeneous tumors with different hormone receptor status. Conclusions CESM enhancement is associated with the proliferation of tumoral cells, as well as to the expression of estrogen and progesterone receptors. As CESM is a relatively young imaging technique, a few related works were found; this may be due to the “off-label” modality. In the next few years, the role of CESM in breast cancer diagnostics will be more thoroughly investigated.
Collapse
Affiliation(s)
- Federica Vasselli
- Radiology and Diagnostic Imaging, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
| | - Alessandra Fabi
- Precision Medicine in Breast Cancer Unit, Fondazione Policlinico Universitario A. Gemelli, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Francesca Romana Ferranti
- Radiology and Diagnostic Imaging, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
| | - Maddalena Barba
- Division of Medical Oncology 2, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
| | - Claudio Botti
- Division of Breast Surgery, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
| | - Antonello Vidiri
- Radiology and Diagnostic Imaging, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
- *Correspondence: Antonello Vidiri,
| | - Silvia Tommasin
- Human Neuroscience Department, Sapienza University of Rome, Rome, Italy
- Neuroimmunology Unit, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Fondazione Santa Lucia, Rome, Italy
| |
Collapse
|
10
|
Wang S, Wang Z, Li R, You C, Mao N, Jiang T, Wang Z, Xie H, Gu Y. Association between quantitative and qualitative image features of contrast-enhanced mammography and molecular subtypes of breast cancer. Quant Imaging Med Surg 2022; 12:1270-1280. [PMID: 35111622 DOI: 10.21037/qims-21-589] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 09/24/2021] [Indexed: 01/21/2023]
Abstract
Background The molecular subtype of breast cancer is one of the most important factors affecting patient prognosis. The study aimed to analyze the association between quantitative and qualitative features of contrast-enhanced mammography (CEM) images and breast cancer molecular subtypes. Methods This retrospective double-center study included women who underwent CEM between November 2017 and April 2020. Each patient had at least 1 malignant lesion confirmed by pathology. The CEM images were evaluated by 2 radiologists to obtain quantitative and qualitative image features. The molecular subtypes were studied as dichotomous outcomes, including luminal versus non-luminal, human epidermal growth factor receptor (HER2)-enriched versus non-HER2-enriched, and triple-negative breast cancer (TNBC) versus non-TNBC subtypes. The association between the image features and molecular subtypes was analyzed by multivariate logistic regression, with odds ratios (ORs) and 95% confidence intervals (CIs) provided. Results A total of 151 patients with 160 malignant lesions were included in the study. For quantitative features, a higher standard deviation of lesion density was associated with non-luminal (OR =0.88, 95% CI: 0.81 to 0.96, P=0.004) and HER2-enriched breast cancers (OR =1.16, 95% CI: 1.04 to 1.28, P=0.006). The relative degree of enhancement (RDE) and contrast-to-noise ratio (CNR) were not associated with molecular subtypes. However, a higher CNR/lesion size (OR =1.06, 95% CI: 1.01 to 1.12, P=0.012) was associated with luminal subtype cancers, and a higher RDE/lesion size (OR =0.94, 95% CI: 0.88 to 1.00, P=0.035) or a higher CNR/lesion size (OR =0.94, 95% CI: 0.88-1.00, P=0.038) was associated with non-TNBCs. For qualitative features, the presence of calcification was associated with HER2-enriched breast cancers (OR =2.91, 95% CI: 1.10 to 7.67, P=0.031). The presence of architectural distortion was associated with luminal cancer (OR =14.50, 95% CI: 1.91 to 110.14, P=0.010) and non-TNBC (OR =0.05, 95% CI: 0.00 to 0.43, P=0.022). Non-mass enhancement (OR =2.78, 95% CI: 1.08 to 7.14, P=0.033) was associated with HER2-enriched breast cancers. An association remained after adjustments for age, breast thickness, and breast density (all adjusted P<0.050). Conclusions The quantitative and qualitative imaging features of CEM could contribute to distinguishing breast cancer molecular subtypes.
Collapse
Affiliation(s)
- Simin Wang
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | | | - Ruimin Li
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Chao You
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Ning Mao
- Department of Radiology, Yantai Yuhuangding Hospital, Qingdao University, Qingdao, China
| | - Tingting Jiang
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Zhongyi Wang
- Department of Radiology, Yantai Yuhuangding Hospital, Qingdao University, Qingdao, China
| | - Haizhu Xie
- Department of Radiology, Yantai Yuhuangding Hospital, Qingdao University, Qingdao, China
| | - Yajia Gu
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| |
Collapse
|
11
|
Cozzi A, Magni V, Zanardo M, Schiaffino S, Sardanelli F. Contrast-enhanced Mammography: A Systematic Review and Meta-Analysis of Diagnostic Performance. Radiology 2021; 302:568-581. [PMID: 34904875 DOI: 10.1148/radiol.211412] [Citation(s) in RCA: 55] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Contrast-enhanced mammography (CEM) is a promising technique for breast cancer detection, but conflicting results have been reported in previous meta-analyses. Purpose To perform a systematic review and meta-analysis of CEM diagnostic performance considering different interpretation methods and clinical settings. Materials and Methods The MEDLINE, EMBASE, Web of Science, and Cochrane Library databases were systematically searched up to July 15, 2021. Prospective and retrospective studies evaluating CEM diagnostic performance with histopathology and/or follow-up as the reference standard were included. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Summary diagnostic odds ratio and area under the receiver operating characteristic curve were estimated with the hierarchical summary receiver operating characteristic (HSROC) model. Summary estimates of sensitivity and specificity were obtained with the hierarchical bivariate model, pooling studies with the same image interpretation approach or focused on the same findings. Heterogeneity was investigated through meta-regression and subgroup analysis. Results Sixty studies (67 study parts, 11 049 CEM examinations in 10 605 patients) were included. The overall area under the HSROC curve was 0.94 (95% CI: 0.91, 0.96). Pooled diagnostic odds ratio was 55.7 (95% CI: 42.7, 72.7) with high heterogeneity (τ2 = 0.3). At meta-regression, CEM interpretation with both low-energy and recombined images had higher sensitivity (95% vs 94%, P < .001) and specificity (81% vs 71%, P = .03) compared with recombined images alone. At subgroup analysis, CEM showed a 95% pooled sensitivity (95% CI: 92, 97) and a 78% pooled specificity (95% CI: 66, 87) from nine studies in patients with dense breasts, while in 10 studies on mammography-detected suspicious findings, CEM had a 92% pooled sensitivity (95% CI: 89, 94) and an 84% pooled specificity (95% CI: 73, 91). Conclusion Contrast-enhanced mammography demonstrated high performance in breast cancer detection, especially with joint interpretation of low-energy and recombined images. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Bahl in this issue.
Collapse
Affiliation(s)
- Andrea Cozzi
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| | - Veronica Magni
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| | - Moreno Zanardo
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| | - Simone Schiaffino
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| | - Francesco Sardanelli
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| |
Collapse
|
12
|
La Forgia D, Fanizzi A, Campobasso F, Bellotti R, Didonna V, Lorusso V, Moschetta M, Massafra R, Tamborra P, Tangaro S, Telegrafo M, Pastena MI, Zito A. Radiomic Analysis in Contrast-Enhanced Spectral Mammography for Predicting Breast Cancer Histological Outcome. Diagnostics (Basel) 2020; 10:E708. [PMID: 32957690 PMCID: PMC7555402 DOI: 10.3390/diagnostics10090708] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 09/07/2020] [Accepted: 09/16/2020] [Indexed: 02/07/2023] Open
Abstract
Contrast-Enhanced Spectral Mammography (CESM) is a recently introduced mammographic method with characteristics particularly suitable for breast cancer radiomic analysis. This work aims to evaluate radiomic features for predicting histological outcome and two cancer molecular subtypes, namely Human Epidermal growth factor Receptor 2 (HER2)-positive and triple-negative. From 52 patients, 68 lesions were identified and confirmed on histological examination. Radiomic analysis was performed on regions of interest (ROIs) selected from both low-energy (LE) and ReCombined (RC) CESM images. Fourteen statistical features were extracted from each ROI. Expression of estrogen receptor (ER) was significantly correlated with variation coefficient and variation range calculated on both LE and RC images; progesterone receptor (PR) with skewness index calculated on LE images; and Ki67 with variation coefficient, variation range, entropy and relative smoothness indices calculated on RC images. HER2 was significantly associated with relative smoothness calculated on LE images, and grading tumor with variation coefficient, entropy and relative smoothness calculated on RC images. Encouraging results for differentiation between ER+/ER-, PR+/PR-, HER2+/HER2-, Ki67+/Ki67-, High-Grade/Low-Grade and TN/NTN were obtained. Specifically, the highest performances were obtained for discriminating HER2+/HER2- (90.87%), ER+/ER- (83.79%) and Ki67+/Ki67- (84.80%). Our results suggest an interesting role for radiomics in CESM to predict histological outcomes and particular tumors' molecular subtype.
Collapse
Affiliation(s)
- Daniele La Forgia
- Struttura Semplice Dipartimentale di Radiologia Senologica, I.R.C.C.S. Istituto Tumori “Giovanni Paolo II”, Viale Orazio Flacco 65, 70124 Bari, Italy;
| | - Annarita Fanizzi
- Struttura Semplice Dipartimentale di Fisica Sanitaria, I.R.C.C.S. Istituto Tumori “Giovanni Paolo II”, Viale Orazio Flacco 65, 70124 Bari, Italy; (A.F.); (V.D.); (P.T.)
| | - Francesco Campobasso
- Dipartimento di Economia e Finanza, Università degli Studi di Bari “Aldo Moro”, Largo Abbazia S. Scolastica, 70124 Bari, Italy;
| | - Roberto Bellotti
- Dipartimento Interateneo di Fisica, Università degli Studi di Bari “Aldo Moro”, Via Giovanni Amendola, 165/a, 70126 Bari, Italy;
- Istituto Nazionale di Fisica Nucleare, Sezione di Bari, Via Giovanni Amendola, 165/a, 70126 Bari, Italy;
| | - Vittorio Didonna
- Struttura Semplice Dipartimentale di Fisica Sanitaria, I.R.C.C.S. Istituto Tumori “Giovanni Paolo II”, Viale Orazio Flacco 65, 70124 Bari, Italy; (A.F.); (V.D.); (P.T.)
| | - Vito Lorusso
- Unità Operativa Complessa di Oncologia Medica, I.R.C.C.S. Istituto Tumori “Giovanni Paolo II”, Viale Orazio Flacco 65, 70124 Bari, Italy;
| | - Marco Moschetta
- Unità Operativa Semplice Dipartimentale Radiodiagnostica ad Indirizzo Senologico, Azienda Ospedaliero-Universitaria Consorziale Policlinico, Piazza Giulio Cesare 11, 70124 Bari, Italy; (M.M.); (M.T.)
| | - Raffaella Massafra
- Struttura Semplice Dipartimentale di Fisica Sanitaria, I.R.C.C.S. Istituto Tumori “Giovanni Paolo II”, Viale Orazio Flacco 65, 70124 Bari, Italy; (A.F.); (V.D.); (P.T.)
| | - Pasquale Tamborra
- Struttura Semplice Dipartimentale di Fisica Sanitaria, I.R.C.C.S. Istituto Tumori “Giovanni Paolo II”, Viale Orazio Flacco 65, 70124 Bari, Italy; (A.F.); (V.D.); (P.T.)
| | - Sabina Tangaro
- Istituto Nazionale di Fisica Nucleare, Sezione di Bari, Via Giovanni Amendola, 165/a, 70126 Bari, Italy;
- Dipartimento di Scienze del Suolo, della Pianta e degli Alimenti, Università degli Studi di Bari Aldo Moro, 70121 Bari, Italy
| | - Michele Telegrafo
- Unità Operativa Semplice Dipartimentale Radiodiagnostica ad Indirizzo Senologico, Azienda Ospedaliero-Universitaria Consorziale Policlinico, Piazza Giulio Cesare 11, 70124 Bari, Italy; (M.M.); (M.T.)
| | - Maria Irene Pastena
- Unità Operativa Complessa di Anatomia Patologica, I.R.C.C.S. Istituto Tumori “Giovanni Paolo II”, Viale Orazio Flacco 65, 70124 Bari, Italy; (M.I.P.); (A.Z.)
| | - Alfredo Zito
- Unità Operativa Complessa di Anatomia Patologica, I.R.C.C.S. Istituto Tumori “Giovanni Paolo II”, Viale Orazio Flacco 65, 70124 Bari, Italy; (M.I.P.); (A.Z.)
| |
Collapse
|