1
|
Ali SA, Abozaed HW, Jazar HA, Mostafa AZH. Surface hardness and wear resistance of prefabricated and CAD-CAM milled artificial teeth: A cross-over clinical study. J Prosthodont 2024. [PMID: 38855812 DOI: 10.1111/jopr.13890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 05/17/2024] [Accepted: 05/22/2024] [Indexed: 06/11/2024] Open
Abstract
PURPOSE To clinically evaluate the surface roughness and wear resistance of prefabricated and CAD-CAM milled acrylic resin teeth for complete dentures. MATERIALS AND METHODS In a cross-over study design, 10 completely edentulous patients were randomly included in this study and given two complete dentures. The first complete denture was made using prefabricated teeth, while the second was constructed using CAD-CAM milled teeth. Following insertion (T0), 3 months (T3), and 6 months (T6), the complete dentures were scanned. Utilizing 3D surface super-imposition techniques, the vertical (2D wear), and volumetric (3D wear) material loss were measured. The hardness of the teeth was evaluated at the time of denture insertion (T0) and then after 6 months (T6) of denture insertion by digital Vickers hardness tester. Statistical analysis was done using SPSS software. Paired groups were compared by paired t-test. Also, a repeated measure test was used. The significant difference was considered if p ≤ 0.05. RESULTS The time of denture function was linearly correlated with the wear of the prefabricated and CAD-CAM milled denture tooth. Prefabricated acrylic teeth had significantly more vertical and volumetric wear after 3 and 6 months, compared to CAD-CAM milled denture teeth where p-values were 0.01, 0.009, 0.003, and 0.024, respectively. Additionally, CAD-CAM milled teeth displayed significantly higher hardness values than prefabricated teeth both before and after 6 months of use where p-values were 0.001. After 6 months, all studied teeth showed a decrease in their hardness. CONCLUSIONS In terms of wear resistance and surface hardness, CAD-CAM milled acrylic resin teeth were superior to prefabricated acrylic resin artificial teeth once the complete denture functions.
Collapse
Affiliation(s)
- Sarah Abdelaal Ali
- External Residence of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Heba Wageh Abozaed
- Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
- Prosthodontics Department, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, Riyadh, Saudi Arabia
| | - Husn A Jazar
- Dental Biomaterials Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Aisha Z H Mostafa
- Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
2
|
Garikano X, Amezua X, Iturrate M, Solaberrieta E. Evaluation of repeatability of different alignment methods to obtain digital interocclusal records: An in vitro study. J Prosthet Dent 2024; 131:709-717. [PMID: 36115710 DOI: 10.1016/j.prosdent.2022.07.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 07/20/2022] [Accepted: 07/20/2022] [Indexed: 10/14/2022]
Abstract
STATEMENT OF PROBLEM The alignment of the maxillary and mandibular digital scans obtained with an intraoral scanner (IOS) generates digital interocclusal records. Although the accuracy of maxillary and mandibular digital scans obtained from an IOS is widely studied, the accuracy of digital interocclusal records obtained with them is not; even less studied is the accuracy (trueness and precision) of the alignment methods that are available to obtain them. PURPOSE The purpose of this in vitro study was to assess the precision under repeatability conditions (repeatability) of the different alignment methods used to obtain digital interocclusal records. MATERIAL AND METHODS Digital scans of maxillary and mandibular casts of a dentate healthy adult were acquired with an IOS. Casts were then mounted in maximum intercuspal position in a semi-adjustable mechanical articulator (1801 AR Model PSH Articulator), and left and right occlusal digital scans were acquired with the IOS. Occlusal digital scans were repeated 7 times under repeatability conditions. After obtaining each pair of occlusal digital scans, the software program of the IOS automatically aligned the maxillary and mandibular digital scans with occlusal digital scans (TRI method), resulting in 7 digital interocclusal records composed of aligned maxillary and mandibular digital scans and occlusal digital scans. All 7 sets of aligned digital scans were exported and realigned in a dental computer-aided design software program by means of global and reference alignment methods (EXO-B and EXO-R methods, respectively). To assess the repeatability, the 7 aligned digital scan sets of each group were repositioned in the common coordinate system by aligning maxillary digital scans, and repeatability was calculated in terms of the distance between the vertices of the mandibular digital scans for each of the possible nonrepeating combinations of pairs (7C2=21). The repeatability was tested by using the Kruskal-Wallis test for nonparametric distribution followed by the Mann-Whitney U test and Bonferroni correction for pairwise comparisons (α=.05). RESULTS The median with interquartile range for the TRI alignment method was 47 (27) μm for the EXO-B method 41 (25) μm and 16 (5) μm for EXO-R. The Kruskal-Wallis test showed statistical difference between test groups (P<.05). The post hoc Dunn test with Bonferroni adjustment detected significant statistical differences between the EXO-R-TRI (P<.001) and EXO-R-EXO-B (P<.001) alignment methods. CONCLUSIONS This study found that the alignment method could influence the repeatability of digital interocclusal records. The reference best-fit alignment method (EXO-R) provided better repeatability.
Collapse
Affiliation(s)
- Xabier Garikano
- Assistant Professor, Department of Graphic Design and Engineering Projects, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain
| | - Xabier Amezua
- Research Assistant, Department of Graphic Design and Engineering Projects, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain; Assistant Professor, Department of Business Management, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain
| | - Mikel Iturrate
- Assistant Professor, Department of Graphic Design and Engineering Projects, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain
| | - Eneko Solaberrieta
- Associate Professor, Department of Graphic Design and Engineering Projects, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain.
| |
Collapse
|
3
|
Schmid T, Dritsas K, Gebistorf M, Halazonetis D, Katsaros C, Gkantidis N. Long-term occlusal tooth wear at the onset of permanent dentition. Clin Oral Investig 2024; 28:155. [PMID: 38366215 PMCID: PMC10873235 DOI: 10.1007/s00784-024-05550-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Accepted: 02/07/2024] [Indexed: 02/18/2024]
Abstract
OBJECTIVES This study quantified the long-term occlusal wear in the natural posterior teeth and the associations per tooth type within the dentition. METHODS The sample included 70 orthodontically treated subjects (52 females and 18 males; median age, 14.3 years), followed for a 12.7-year period. They were consecutively selected with no tooth wear-related criteria. Post-treatment (T1) and follow-up dental casts (T2) were scanned and superimposed through three-dimensional methods. Occlusal wear volume of posterior teeth and tooth wear patterns were investigated through non-parametric statistics and analysis of covariance. RESULTS There were no significant differences between contralateral teeth. The average occlusal wear per posterior tooth was 2.3 mm3, with 65.2% of teeth showing values greater than 1 mm3. Males, mandibular teeth, and first molars exhibited slightly greater wear levels than females (median, 2.57 and 2.21 mm3, respectively; p = 0.005), maxillary teeth, and first or second premolars, respectively. In all first premolars and in the mandibular second premolars, the buccal cusps were primarily affected with no other distinct patterns. There were weak to moderate correlations between tooth types, apart from certain strong correlations detected in males. CONCLUSIONS Posterior tooth wear was highly prevalent after a 13-year period starting at the onset of permanent dentition. The detected patterns are in accordance with the concept of canine guidance occlusion that is transforming into group synergy through function. CLINICAL RELEVANCE The widespread tooth wear occurrence and the high intra- and inter-individual variability underline the need for individual patient monitoring to identify high-risk patients at early stages.
Collapse
Affiliation(s)
- Thomas Schmid
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland
| | - Konstantinos Dritsas
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland
| | - Meret Gebistorf
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland
| | - Demetrios Halazonetis
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, 11527, Athens, Greece
| | - Christos Katsaros
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland
| | - Nikolaos Gkantidis
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland.
| |
Collapse
|
4
|
Gkantidis N, Opacic J, Kanavakis G, Katsaros C, Halazonetis D. Facial asymmetry and midsagittal plane definition in 3D: A bias-free, automated method. PLoS One 2023; 18:e0294528. [PMID: 38011159 PMCID: PMC10681257 DOI: 10.1371/journal.pone.0294528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 10/16/2023] [Indexed: 11/29/2023] Open
Abstract
Symmetry is a fundamental biological concept in all living organisms. It is related to a variety of physical and social traits ranging from genetic background integrity and developmental stability to the perception of physical appearance. Within this context, the study of human facial asymmetry carries a unique significance. Here, we validated an efficient method to assess 3D facial surface symmetry by best-fit approximating the original surface to its mirrored one. Following this step, the midsagittal plane of the face was automatically defined at the midpoints of the contralateral corresponding vertices of the superimposed models and colour coded distance maps were constructed. The method was tested by two operators using facial models of different surface size. The results show that the midsagittal plane definition was highly reproducible (maximum error < 0.1 mm or°) and remained robust for different extents of the facial surface model. The symmetry assessments were valid (differences between corresponding bilateral measurement areas < 0.1 mm), highly reproducible (error < 0.01 mm), and were modified by the extent of the initial surface model. The present landmark-free, automated method to assess facial asymmetry and define the midsagittal plane of the face is accurate, objective, easily applicable, comprehensible and cost effective.
Collapse
Affiliation(s)
- Nikolaos Gkantidis
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Jasmina Opacic
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Georgios Kanavakis
- Department of Orthodontics and Pediatric Dentistry, UZB–University School of Dental Medicine, University of Basel, Basel, Switzerland
| | - Christos Katsaros
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Demetrios Halazonetis
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
5
|
Wan Q, Daher R, Lee H, Kwon HB, Han JS, Lee JH. Reliability of digital repeated-scan superimposition and single-scan techniques for wear volume loss assessment on flat surfaces. J Dent 2023; 138:104738. [PMID: 37806382 DOI: 10.1016/j.jdent.2023.104738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 09/14/2023] [Accepted: 10/05/2023] [Indexed: 10/10/2023] Open
Abstract
OBJECTIVES Evidence on the reliability of digital techniques for wear volume assessment using three-dimensional (3D) scan datasets is scarce. This study evaluated the reliability of a repeated-scan superimposition technique and two single-scan techniques in assessing wear volume loss on flat surfaces of 3D-printed resin specimens. METHODS Cuboid-shaped (15×10×10 mm) resin specimens were 3D-printed (n = 14) and scanned before and after 200,000 cycles of masticatory simulation. For the repeated-scan superimposition technique, digital 3D models of specimens before and after masticatory simulation were superimposed, and the volume loss was determined. The first single-scan technique utilized a computer-aided design freeware program, while the second one employed a 3D-metrology software program. In the freeware program, the worn area of 3D objects was edited directly to obtain a flat surface. In the 3D-metrology software program, the worn area was deleted first and then filled to the flat surface. The volume differences before and after editing were calculated in each software program. Agreement between the three measurement techniques was determined through intraclass correlation coefficients (ICCs). One-way analysis of variance was performed to compare the wear volume loss assessed by the three techniques (α = 0.05). RESULTS High inter-technique reliability was observed between the three assessment techniques (ICC = 0.998, p < .001). On pair-wise comparisons of two of the three techniques, all pairs showed high consistency (ICC ≥ 0.999, p < .001). No significant difference was found in the wear volume loss assessed using the three techniques (p = .996). CONCLUSIONS Digital repeated-scan superimposition and two single-scan techniques demonstrated high reliability in assessing wear volume loss on flat surfaces. CLINICAL SIGNIFICANCE The repeated-scan superimposition technique can be effectively utilized to assess wear volume loss of anatomically shaped specimens and flat surfaces. This study indicates that the single-scan techniques may serve as a suitable alternative to the repeated-scan superimposition technique when evaluating wear volume loss of flat surfaces.
Collapse
Affiliation(s)
- Qiucen Wan
- Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - René Daher
- Division of Cariology and Endodontology, Clinique Universitaire de Médecine Dentaire (CUMD), University of Geneva, Geneva, Switzerland
| | - Hyeonjong Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Ho-Beom Kwon
- Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jung-Suk Han
- Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jae-Hyun Lee
- Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.
| |
Collapse
|
6
|
Beleidy M, Ziada A. 3D Surface Deviation Wear Analysis of Veneered PEEK Crowns and Its Correlation with Optical Digital Profilometry. J Prosthodont 2023; 32:32-39. [PMID: 35118735 DOI: 10.1111/jopr.13490] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 01/31/2022] [Indexed: 01/25/2023] Open
Abstract
PURPOSE To verify whether 3D surface deviation analysis software can detect the surface changes of composite veneered polyetheretherketone posterior crowns following wear simulation compared to optical digital profilometry. MATERIALS AND METHODS Twenty dental crowns, fabricated from CAD-CAM polyetheretherketone (PEEK) and veneered with high impact polymer composite (HIPC), were subjected to wear test (50N, 5/55°C; 120,000 chewing cycles). Optical digital profilometry and 3D surface deviation using Geomagic design X software was used before and after the wear test to measure volumetric wear loss (mm3 ). The data were statistically analyzed with Wilcoxon signed-rank test to compare the two methodologies. The significance level was set at p ≤ 0.05. RESULTS There was no statistically significant difference between the two assessment methods (p-value = 0.075, Effect size = 0.854). Regarding the optical digital profilometry analysis, HIPC veneered PEEK crowns showed 0.01686 (0.018-0.02155) mm3 as a median volumetric wear loss value. While the crowns analyzed by 3D surface deviation showed -0.0398 (-0.0913 to -0.0042) mm3 as a median volumetric loss value (p-value = 0.075, Effect size = 0.854). In addition, there was no statistically significant correlation between wear measurements by optical digital profilometry and 3D surface deviation analyses (ρ = -0.177, p-value = 0.685). CONCLUSIONS There was no significant difference or correlation between optical digital profilometry and 3D surface deviation analyses for volumetric wear loss of veneered PEEK crowns.
Collapse
Affiliation(s)
- Marwa Beleidy
- Department of Fixed Prosthodontics, Faculty of Dentistry, October 6th University, Giza, Egypt
| | - Ahmed Ziada
- Department of Fixed Prosthodontics, Faculty of Dentistry, Benisuef University, Benisuef, Egypt
| |
Collapse
|
7
|
Accurate gingival recession quantification using 3D digital dental models. Clin Oral Investig 2022; 27:1697-1705. [PMID: 36424472 PMCID: PMC10102060 DOI: 10.1007/s00784-022-04795-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Accepted: 11/14/2022] [Indexed: 11/26/2022]
Abstract
Abstract
Objectives
To develop and validate a method for accurate quantitative assessment of gingival recessions based on superimposition of serial 3D digital models.
Materials and methods
Gingival recessions of mild (0.5–2 mm) and increased (3–7 mm) severity were simulated on stone casts and surface models were created. The outlines of the gingival margins of the mild (A) and severe recessions (B) were compared to the original gingival margins following 3D best fit superimposition through a gold standard technique (GS), which used intact adjacent structures, and the tested method (CC), which used single tooth crowns at the position of recessions, as superimposition reference. The primary outcome was the distance between the most apical point of each corresponding gingival margin along the respective tooth long axis.
Results
For mild recessions, the median difference of the test methods (CC_A) from the reference method (GS_A) was 0.008 mm (IQR: 0.093; range: − 0.143, 0.147). For severe recessions, the median difference of the test method (CC_B) from the reference method (GS_B) was 0.009 mm (IQR: 0.091; range: − 0.170, 0.198). The proposed method (CC) showed very high intra- and inter-operator reproducibility (median: 0.025 and 0.033 mm, respectively).
Conclusions
The suggested method offers highly accurate monitoring of gingival margin changes and diagnosis of gingival recessions using 3D digital dental models. The method is applicable irrespective of changes in tooth position or form, allowing for assessments over any time span.
Clinical relevance
The accurate detection and visualization of gingival margin changes in 3D will enhance diagnosis and patient-doctor communication.
Collapse
|
8
|
Winkler J, Sculean A, Gkantidis N. Intraoral Scanners for In Vivo 3D Imaging of the Gingiva and the Alveolar Process. J Clin Med 2022; 11:6389. [PMID: 36362615 PMCID: PMC9655054 DOI: 10.3390/jcm11216389] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/13/2022] [Accepted: 10/25/2022] [Indexed: 11/30/2023] Open
Abstract
This study aimed to assess the reliability of two intraoral surface scanners for the representation of the alveolar process in vivo. Complete maxillary scans (CS 3600, Carestream and TRIOS 3, 3Shape) were repeatedly obtained from 13 fully dentate individuals. Scanner precision and agreement were tested using 3D surface superimpositions on the following reference areas: the buccal front teeth area, the entire dental arch, the entire alveolar process, or single teeth by applying an iterative closest point algorithm. Following each superimposition, the mean absolute distance (MAD) between predefined 3D model surfaces was calculated. Outcomes were analyzed through non-parametric statistics and the visualization of color-coded distance maps. When superimpositions were performed on the alveolar process, the median scanner precision was below 0.05 mm, with statistically significant but negligible differences between scanners. The agreement between the scanners was approximately 0.06 mm. When single-tooth superimpositions were used to assess the precision of adjacent alveolar soft-tissue surfaces, the median error was 0.028 mm, and there was higher agreement between the scanners. The in vivo reliability of the intraoral scanners in the alveolar surface area was high overall. Single-tooth superimpositions should be preferred for the optimal assessment of neighboring alveolar surface areas relative to the dentition.
Collapse
Affiliation(s)
- Jonas Winkler
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, CH-3010 Bern, Switzerland
| | - Anton Sculean
- Department of Periodontology, School of Dental Medicine, University of Bern, CH-3010 Bern, Switzerland
| | - Nikolaos Gkantidis
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, CH-3010 Bern, Switzerland
| |
Collapse
|
9
|
Wear behavior and abrasiveness of monolithic CAD/CAM ceramics after simulated mastication. Clin Oral Investig 2022; 26:6593-6605. [PMID: 35819543 PMCID: PMC9643261 DOI: 10.1007/s00784-022-04611-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 06/28/2022] [Indexed: 11/30/2022]
Abstract
Objectives To evaluate the wear resistance and abrasiveness of monolithic CAD/CAM ceramics. Materials and methods Rectangular-shaped specimens (12 mm × 6.5 mm × 1.5 mm) were sectioned from the following CAD/CAM blocks (n = 10); partially crystallized lithium disilicate (PLD), experimental fully crystallized lithium disilicate (FLD), zirconia-reinforced lithium silicate (ZLS), super-translucent monolithic zirconia (SMZ), and ultra-translucent monolithic zirconia (UMZ). Silicon carbide papers were used to mechanically flatten and polish the surfaces. PLD specimens were subjected to a combined crystallization/glazing firing cycle. Ceramic specimens were mounted to the wear device and tested for 200,000 cycles against human premolars at 20 N force and 2 mm sliding distance. Artificial saliva was used as a lubricant. The teeth were scanned using micro-CT before and after the wear test and the generated models were overlapped to determine the volumetric tooth loss. Before and after the test, specimens’ weights and surface roughness (Ra) values were measured, and the differences were calculated. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) were utilized for microstructural and chemical analysis. Statistical analysis was performed using one-way ANOVA or an equivalent test for non-parametric results. Significance level was set at P ≤ 0.05. Results The type of ceramic material affected the ceramic and antagonist wear rates (P < 0.001). PLD and ZLS had the highest ceramic and antagonist wear, whereas UMZ and SMZ demonstrated the lowest wear values. The FLD group showed comparable antagonist wear and significantly less ceramic wear than PLD and ZLS. Conclusions Monolithic zirconia demonstrated the best wear resistance and least abrasiveness to the antagonist. The experimental lithium disilicate was more wear-resistant than other glass–ceramic groups. Clinical relevance Monolithic zirconia is wear-resistant and gentle on the antagonist. In contrast, glass–ceramics are more abrasive to enamel. Supplementary Information The online version contains supplementary material available at 10.1007/s00784-022-04611-w.
Collapse
|
10
|
Wang B, Huang M, Dang P, Xie J, Zhang X, Yan X. PEEK in Fixed Dental Prostheses: Application and Adhesion Improvement. Polymers (Basel) 2022; 14:polym14122323. [PMID: 35745900 PMCID: PMC9228596 DOI: 10.3390/polym14122323] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/06/2022] [Accepted: 06/07/2022] [Indexed: 01/27/2023] Open
Abstract
Polyetheretherketone (PEEK) has been widely applied in fixed dental prostheses, comprising crowns, fixed partial dentures, and post-and-core. PEEK’s excellent mechanical properties facilitate better stress distribution than conventional materials, protecting the abutment teeth. However, the stiffness of PEEK is not sufficient, which can be improved via fiber reinforcement. PEEK is biocompatible. It is nonmutagenic, noncytotoxic, and nonallergenic. However, the chemical stability of PEEK is a double-edged sword. On the one hand, PEEK is nondegradable and intraoral corrosion is minimized. On the other hand, the inert surface makes adhesive bonding difficult. Numerous strategies for improving the adhesive properties of PEEK have been explored, including acid etching, plasma treatment, airborne particle abrasion, laser treatment, and adhesive systems.
Collapse
Affiliation(s)
- Biyao Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Minghao Huang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
| | - Pengrui Dang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Jiahui Xie
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Xinwen Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| | - Xu Yan
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| |
Collapse
|
11
|
Lee JH, Myagmar G, Kwon HB, Han JS. A digital method for wear volume loss analysis using a single-scan three-dimensional dataset. J Dent Sci 2022; 17:638-641. [PMID: 35028110 PMCID: PMC8740104 DOI: 10.1016/j.jds.2021.06.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/14/2021] [Indexed: 11/16/2022] Open
Abstract
A straightforward digital method of evaluating wear volume loss is described. This method allows the measurement of the wear by analyzing only the three-dimensional scan dataset of the worn specimen without needing a separate baseline scan. Compared to the conventional method, involving superimposition of the two datasets scanned before and after the wear test, this method can reduce labor and accuracy errors caused by repeated scans and superimposition procedures. Further, this analysis can be conducted using free computer-aided design software, which makes it more efficient for the analysis of wear volume loss of restorative materials.
Collapse
Affiliation(s)
- Jae-Hyun Lee
- Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, South Korea.,MAS Program of Digital Dental Technologies, University Clinics of Dental Medicine, Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Gerelmaa Myagmar
- Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, South Korea
| | - Ho-Beom Kwon
- Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, South Korea
| | - Jung-Suk Han
- Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, South Korea
| |
Collapse
|
12
|
Abhay SS, Ganapathy D, Veeraiyan DN, Ariga P, Heboyan A, Amornvit P, Rokaya D, Srimaneepong V. Wear Resistance, Color Stability and Displacement Resistance of Milled PEEK Crowns Compared to Zirconia Crowns under Stimulated Chewing and High-Performance Aging. Polymers (Basel) 2021; 13:polym13213761. [PMID: 34771318 PMCID: PMC8587121 DOI: 10.3390/polym13213761] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 10/27/2021] [Accepted: 10/28/2021] [Indexed: 12/19/2022] Open
Abstract
Recently, polyetheretherketone (PEEK) has been introduced to the dental market as a high-performance and chemically inert biomaterial. This study aimed to compare the wear resistance, abrasiveness, color stability, and displacement resistance of zirconia and PEEK milled crowns. An ideal tooth preparation of a first maxillary molar was done and scanned by an intraoral scanner to make a digital model. Then, the prosthetic crown was digitally designed on the CAD software, and the STL file was milled in zirconia (CaroZiir S, Carol Zircolite Pvt. Ltd., Gujarat, India) and PEEK (BioHpp, Bredent GmbH, Senden, Germany) crowns using five-axis CNC milling machines. The wear resistance, color stability, and displacement resistance of the milled monolithic zirconia with unfilled PEEK crowns using a chewing simulator with thermocyclic aging (120,000 cycles) were compared. The antagonist wear, material wear, color stability, and displacement were evaluated and compared among the groups using the Wilcoxon-Mann-Whitney U-test. Zirconia was shown to be three times more abrasive than PEEK (p value < 0.05). Zirconia had twice the wear resistance of PEEK (p value < 0.05). Zirconia was more color stable than PEEK (p value < 0.05). PEEK had more displacement resistance than zirconia (p value < 0.05). PEEK offers minimal abrasion, better stress modulation through plastic deformation, and good color stability, which make it a promising alternative to zirconia crown.
Collapse
Affiliation(s)
- Simone Shah Abhay
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
| | - Dhanraj Ganapathy
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
| | - Deepak Nallaswamy Veeraiyan
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
| | - Padma Ariga
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
| | - Artak Heboyan
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, Yerevan 0025, Armenia
| | - Pokpong Amornvit
- Golden Jubilee Medical Centre, Mahidol University, Nakon Pathom, Salaya 73170, Thailand;
| | - Dinesh Rokaya
- Department of Clinical Dentistry, International College of Dentistry, Walailak University, Bangkok 10400, Thailand
- Correspondence: (D.R.); (V.S.); Tel.: +66-2218-8535 (V.S.)
| | - Viritpon Srimaneepong
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
- Correspondence: (D.R.); (V.S.); Tel.: +66-2218-8535 (V.S.)
| |
Collapse
|
13
|
Wampfler JJ, Gkantidis N. Superimposition of serial 3-dimensional facial photographs to assess changes over time: A systematic review. Am J Orthod Dentofacial Orthop 2021; 161:182-197.e2. [PMID: 34688517 DOI: 10.1016/j.ajodo.2021.06.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 06/01/2021] [Accepted: 06/01/2021] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Superimpositions of 3-dimensional photographs enable a thorough and risk-free assessment of facial changes over time. However, the available methods and the evidence supporting them have not been assessed systematically. The paper summarizes and assesses the current evidence on superimposition methods of serial 3-dimensional facial photographs available in the literature. METHODS The following databases were searched without time restriction (last updated December 2020): MEDLINE via PubMed, EMBASE, Cochrane Library, and Google Scholar. Unpublished literature was searched on Open Grey and Grey Literature Report. Authors were contacted if necessary, and reference lists of relevant papers were screened. All studies with sample size ≥6 that tested the accuracy or precision of a superimposition technique, or agreement between different techniques regarding facial surface changes, were considered. The 2 authors performed data extraction independently using predefined forms. The risk of bias was assessed through the Quality Assessment and Diagnostic Accuracy Tool 2 tool. RESULTS Eight studies fulfilled the inclusion criteria. The total risk of bias of 7 studies was high and of 1 low. Seven studies had high total applicability concerns, and 1 was unclear. There was high heterogeneity among studies, which tested constructed planes through manually selected landmarks, a configuration of 9 landmarks, various surface areas, and the entire facial surface as superimposition references. A small rectangular area on the forehead combined with one on the middle part of the nose and the lower wall of the orbital foramen showed promising results. CONCLUSIONS The limited available evidence suggests that surface-based registration is superior to landmark-based registration. Further research in the field is mandatory.
Collapse
Affiliation(s)
- Jonathan Johannes Wampfler
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Nikolaos Gkantidis
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
14
|
Ning K, Bronkhorst E, Bremers A, Bronkhorst H, van der Meer W, Yang F, Leeuwenburgh S, Loomans B. Wear behavior of a microhybrid composite vs. a nanocomposite in the treatment of severe tooth wear patients: A 5-year clinical study. Dent Mater 2021; 37:1819-1827. [PMID: 34565582 DOI: 10.1016/j.dental.2021.09.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 09/07/2021] [Accepted: 09/13/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE This study aimed to compare the wear behavior of a microhybrid composite vs. a nanocomposite in patients suffering from severe tooth wear. METHODS A convenience sample of 16 severe tooth wear patients from the Radboud Tooth Wear Project was included. Eight of them were treated with a microhybrid composite (Clearfil APX, Kuraray) and the other eight with a nanocomposite (Filtek Supreme XTE, 3M). The Direct Shaping by Occlusion (DSO) technique was used for all patients. Clinical records were collected after 1 month (baseline) as well as 1, 3 and 5 years post-treatment. The maximum height loss at specific areas per tooth was measured with Geomagic Qualify software. Intra-observer reliability was tested with paired t-tests, while multilevel logistic regression analyses were used to compare odds ratios (OR) of "large amount of wear". RESULTS Intra-observer reliability tests confirmed that two repeated measurements agreed well (p > 0.136). For anterior mandibular teeth, Filtek Supreme showed significantly less wear than Clearfil APX; in maxillary anterior teeth, Clearfil APX showed significantly less wear (OR material = 0.28, OR jaw position = 0.079, p < 0.001). For premolar and molar teeth, Filtek Supreme showed less wear in bearing cusps, whereas Clearfil APX showed less wear in non-bearing cusps (premolar: OR material = 0.42, OR bearing condition = 0.18, p = 0.001; molar: OR material = 0.50, OR bearing condition = 0.14, p < 0.001). SIGNIFICANCE Nanocomposite restorations showed significantly less wear at bearing cusps, whereas microhybrid composite restorations showed less wear at non-bearing cusps and anterior maxillary teeth.
Collapse
Affiliation(s)
- K Ning
- Radboud University Medical Center, Radboud Institute for Molecular Life Sciences, Department of Dentistry - Regenerative Biomaterials, Philips van Leydenlaan 25, Nijmegen, The Netherlands
| | - E Bronkhorst
- Radboud University Medical Center, Radboud Institute for Health Sciences, Department of Dentistry - Restorative Dentistry, Philips van Leydenlaan 25, Nijmegen, The Netherlands
| | - A Bremers
- Radboud University Medical Center, Radboud Institute for Health Sciences, Department of Dentistry - Restorative Dentistry, Philips van Leydenlaan 25, Nijmegen, The Netherlands
| | - H Bronkhorst
- Radboud University Medical Center, Radboud Institute for Health Sciences, Department of Dentistry - Restorative Dentistry, Philips van Leydenlaan 25, Nijmegen, The Netherlands
| | - W van der Meer
- University of Groningen, University Medical Center Groningen, Department of Orthodontics, Groningen, The Netherlands; W.J. Kolff Institute of Biomedical Engineering and Materials Science, Groningen, The Netherlands
| | - F Yang
- Radboud University Medical Center, Radboud Institute for Molecular Life Sciences, Department of Dentistry - Regenerative Biomaterials, Philips van Leydenlaan 25, Nijmegen, The Netherlands
| | - S Leeuwenburgh
- Radboud University Medical Center, Radboud Institute for Molecular Life Sciences, Department of Dentistry - Regenerative Biomaterials, Philips van Leydenlaan 25, Nijmegen, The Netherlands
| | - B Loomans
- Radboud University Medical Center, Radboud Institute for Health Sciences, Department of Dentistry - Restorative Dentistry, Philips van Leydenlaan 25, Nijmegen, The Netherlands.
| |
Collapse
|
15
|
Valid 3D surface superimposition references to assess facial changes during growth. Sci Rep 2021; 11:16456. [PMID: 34385558 PMCID: PMC8361153 DOI: 10.1038/s41598-021-95942-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 08/03/2021] [Indexed: 11/08/2022] Open
Abstract
Currently, the primary techniques applied for the assessment of facial changes over time utilize 2D images. However, this approach has important limitations related to the dimensional reduction and the accuracy of the used data. 3D facial photography has been recently introduced as a risk-free alternative that overcomes these limitations. However, the proper reference areas that should be used to superimpose serial 3D facial images of growing individuals are not yet known. Here, we tested various 3D facial photo superimposition reference areas and compared their outcomes to those of a standard anterior cranial base superimposition technique. We found that a small rectangular area on the forehead plus an area including the middle part of the nose and the lower wall of the orbital foramen provided comparable results to the standard technique and showed adequate reproducibility. Other reference areas that have been used so far in the literature were less reliable. Within the limitations of the study, a valid superimposition reference area for serial 3D facial images of growing individuals is suggested. The method has potential to greatly expand the possibilities of this highly informative, risk free, and easily obtained 3D tool for the assessment of facial changes in growing individuals.
Collapse
|
16
|
Winkler J, Gkantidis N. Intraoral scanners for capturing the palate and its relation to the dentition. Sci Rep 2021; 11:15489. [PMID: 34326472 PMCID: PMC8322384 DOI: 10.1038/s41598-021-95103-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 07/12/2021] [Indexed: 12/18/2022] Open
Abstract
Proper superimposition of intraoral scan generated 3D models enables detailed assessment of soft and hard tissue surface changes. This requires accurate 3D models and stable structures as superimposition references. In the maxilla, different reference areas have been proposed, mostly located at the palatal region. In this in vivo study we evaluated the precision of two intraoral scanners (TRIOS 3, 3Shape and CS 3600, Carestream) at the maxilla, focusing on the palate itself and also on its spatial relation to the dentition, following palatal superimposition. Precision was tested through the superimposition of repeated scans on the palate and the dental arch. Overall, the median precision of both scanners was high (< 0.1 mm). Scanner precision was comparable when the palatal area was tested individually. However, TRIOS 3 showed higher precision regarding the assessment of the dental arch, following superimposition of repeated models on the palate (median difference: approximately 40 μm). In few cases, local areas of higher imprecision were present for both scanners, exceeding 0.3 mm. Thus, scanner precision seems to be high in small, but slightly reduced considering larger areas, with differences between scanners. However, the effect on individual tooth position relative to the palate was for both scanners limited.
Collapse
Affiliation(s)
- Jonas Winkler
- Department of Orthodontics and Dentofacial Orthopedics, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland
| | - Nikolaos Gkantidis
- Department of Orthodontics and Dentofacial Orthopedics, University of Bern, Freiburgstrasse 7, CH-3010, Bern, Switzerland.
| |
Collapse
|
17
|
Longitudinal 3D Study of Anterior Tooth Wear from Adolescence to Adulthood in Modern Humans. BIOLOGY 2021; 10:biology10070660. [PMID: 34356515 PMCID: PMC8301389 DOI: 10.3390/biology10070660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 07/09/2021] [Accepted: 07/11/2021] [Indexed: 11/23/2022]
Abstract
Simple Summary Tooth wear is the loss of tooth substance during everyday functioning by means other than dental caries. It is expected at a certain level in every person, and it increases with age. In the last decades, due to the increased life expectancy and high patient demands, it has become an important problem modern dentistry has to face. However, the average amount of tooth wear among individuals remains controversial. The purpose of this clinical study was to precisely detect the extent of anterior tooth wear over a thirteen-year period, from adolescence to adulthood. The present study revealed the very high tooth wear occurrence in the population already at early adulthood and showed that wear monitoring at an individual level is important for dentists to enable the better understanding of the problem and allow timely targeted interventions for patients in need. These might be preventive, such as the prescription of mouth guards to limit grinding and the cessation of harmful habits that lead to tooth wear, or interceptive, such as the restoration of the lost tooth substance to stop the progress of the condition and improve esthetics and function. Abstract In modern humans, tooth wear can easily be observed as a loss of tooth substance, but its precise measurement is problematic. The aim of this longitudinal cohort study was to determine the precise amount of occlusal tooth wear in the anterior permanent dentition from adolescence to adulthood. Corresponding tooth crowns from serial 3D digital dental models of 72 individuals were best fit-approximated by applying novel, highly accurate 3D superimposition methods. The superimposed crowns were simultaneously sliced on intact structures, and the differences in the volumes of the subsequent occlusal parts were calculated. Over a thirteen-year period, there was an average loss of anterior occlusal surfaces of 1.58 mm3 per tooth. Tooth surface loss in at least one tooth was higher than 1 mm3 in 93.1% of the human subjects. Tooth wear severity differed by sex and tooth type, with males showing higher values versus females and upper canines versus other anterior teeth. The study revealed the endemic occurrence of occlusal anterior tooth wear, highlighting the need for monitoring of the condition in the population to identify high-risk patients and enable timely interventions. The novel methods applied here on 3D digital models are recommended for this.
Collapse
|
18
|
Gkantidis N, Dritsas K, Katsaros C, Halazonetis D, Ren Y. 3D Occlusal Tooth Wear Assessment in Presence of Limited Changes in Non-Occlusal Surfaces. Diagnostics (Basel) 2021; 11:diagnostics11061033. [PMID: 34199782 PMCID: PMC8228780 DOI: 10.3390/diagnostics11061033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 05/31/2021] [Accepted: 06/01/2021] [Indexed: 12/15/2022] Open
Abstract
The study aimed to develop an accurate and convenient 3D occlusal tooth wear assessment technique, applicable when surfaces other than the occlusal undergo changes during the observation period. Various degrees of occlusal tooth wear were simulated in vitro on 18 molar and 18 premolar plaster teeth. Additionally, their buccal and lingual surfaces were gently grinded to induce superficial changes and digital dental models were generated. The grinded and the original tooth crowns were superimposed using six different 3D techniques (two reference areas with varying settings; gold standard: GS). Superimposition on intact structures provided the GS measurements. Tooth wear volume comprised the primary outcome measure. All techniques differed significantly to each other in their accuracy (p < 0.001). The technique of choice (CCD: complete crown with 30% estimated overlap of meshes) showed excellent agreement with the GS technique (median difference: 0.045, max: 0.219 mm3), no systematic error and sufficient reproducibility (max difference < 0.040 mm3). Tooth type, tooth alignment in the dental arches, and amount of tooth wear did not significantly affect the results of the CCD technique (p > 0.01). The suggested occlusal tooth wear assessment technique is straightforward and offers accurate outcomes when limited morphological changes occur on surfaces other than the occlusal.
Collapse
Affiliation(s)
- Nikolaos Gkantidis
- Department of Orthodontics and Dentofacial Orthopedics, University of Bern, CH-3010 Bern, Switzerland; (K.D.); (C.K.)
- Department of Orthodontics, W.J. Kolff Institute, University Medical Center Groningen, University of Groningen, 9700RB Groningen, The Netherlands;
- Correspondence: or
| | - Konstantinos Dritsas
- Department of Orthodontics and Dentofacial Orthopedics, University of Bern, CH-3010 Bern, Switzerland; (K.D.); (C.K.)
| | - Christos Katsaros
- Department of Orthodontics and Dentofacial Orthopedics, University of Bern, CH-3010 Bern, Switzerland; (K.D.); (C.K.)
| | - Demetrios Halazonetis
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, GR-11527 Athens, Greece;
| | - Yijin Ren
- Department of Orthodontics, W.J. Kolff Institute, University Medical Center Groningen, University of Groningen, 9700RB Groningen, The Netherlands;
| |
Collapse
|
19
|
Travassos da Rosa Moreira Bastos R, Teixeira da Silva P, Normando D. Reliability of qualitative occlusal tooth wear evaluation using an intraoral scanner: A pilot study. PLoS One 2021; 16:e0249119. [PMID: 33765042 PMCID: PMC7993778 DOI: 10.1371/journal.pone.0249119] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Accepted: 03/11/2021] [Indexed: 11/24/2022] Open
Abstract
Dental wear analysis through the use of an intraoral scanner is a reality of modern dentistry. This study aimed to investigate the reliability of qualitative tooth wear evaluation through three-dimensional images captured with an intraoral scanner and compared to clinical and photographic examinations. Eighteen adult volunteers of both genders (18 to 55 years old) were submitted to clinical exams, intraoral photographs and intraoral scanning protocol using an optical scanner (TRIOS® Pod, 3Shape, Copenhagen, Denmark). Occlusal tooth wear, from second to second premolars, was measured by two evaluators and reevaluated after 30 days, according to a slight modification of the method described by Mockers et al. Weighted Kappa was used to measure intra and inter-examiner agreement. The Friedman test was used to verify the differences among methods. Random and systematic errors were assessed using Bland-Altman plots. All statistical analysis was performed with p<0.05. There was a substantive agreement for clinical (K = 0.75) and photographic exams (K = 0.79) and a moderate agreement for intraoral scanner analysis (K = 0.60) for inter-examiner evaluation. A substantial intra-examiner agreement was obtained for both evaluators. No significant difference between the methods was observed (p = 0.7343 for examiner 1 and 0.8007 for examiner 2). The Bland-Altman plot confirmed no systematic errors between the methods and a random error of 0.25 with the scanner method when compared to clinical assessment. All three methods showed reliability in qualitative occlusal tooth wear evaluation. Intraoral scanning seems to be a sound and reliable tool to evaluate tooth wear when compared to traditional methods, considering the lower inter-examiner agreement and the inherent limitations of this pilot study. Further research will be necessary in order to achieve more robust evidence.
Collapse
Affiliation(s)
| | | | - David Normando
- Department of Orthodontics, Dental School, Federal University of Pará, Belém, Pará, Brazil
| |
Collapse
|
20
|
Gkantidis N, Dritsas K, Katsaros C, Halazonetis D, Ren Y. 3D Method for Occlusal Tooth Wear Assessment in Presence of Substantial Changes on Other Tooth Surfaces. J Clin Med 2020; 9:jcm9123937. [PMID: 33291770 PMCID: PMC7761944 DOI: 10.3390/jcm9123937] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 11/28/2020] [Accepted: 12/01/2020] [Indexed: 12/18/2022] Open
Abstract
Early diagnosis and timely management of tooth or dental material wear is imperative to avoid extensive restorations. Previous studies suggested different methods for tooth wear assessment, but no study has developed a three-dimensional (3D) superimposition technique applicable in cases where tooth surfaces, other than the occlusal, undergo extensive morphological changes. Here, we manually grinded plaster incisors and canines to simulate occlusal tooth wear of varying severity in teeth that received a wire retainer bonded on their lingual surfaces, during the assessment period. The corresponding dental casts were scanned using a surface scanner. The modified tooth crowns were best-fit approximated to the original crowns using seven 3D superimposition techniques (two reference areas with varying settings) and the gold standard technique (GS: intact adjacent teeth and alveolar processes as superimposition reference), which provided the true value. Only a specific technique (complete crown with 20% estimated overlap of meshes), which is applicable in actual clinical data, showed perfect agreement with the GS technique in all cases (median difference: −0.002, max absolute difference: 0.178 mm3). The outcomes of the suggested and the GS technique were highly reproducible (max difference < 0.040 mm3). The presented technique offers low cost, convenient, accurate, and risk-free tooth wear assessment.
Collapse
Affiliation(s)
- Nikolaos Gkantidis
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, CH-3010 Bern, Switzerland; (K.D.); (C.K.)
- Department of Orthodontics, W.J. Kolff Institute, University Medical Center Groningen, University of Groningen, 9700RB Groningen, The Netherlands;
- Correspondence: ; Tel.: +41-(0)-31-632-25-91
| | - Konstantinos Dritsas
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, CH-3010 Bern, Switzerland; (K.D.); (C.K.)
| | - Christos Katsaros
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, CH-3010 Bern, Switzerland; (K.D.); (C.K.)
| | - Demetrios Halazonetis
- Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, GR-11527 Athens, Greece;
| | - Yijin Ren
- Department of Orthodontics, W.J. Kolff Institute, University Medical Center Groningen, University of Groningen, 9700RB Groningen, The Netherlands;
| |
Collapse
|
21
|
Baier W, Norman DG, Donnelly MJ, Williams MA. Forensic 3D printing from micro-CT for court use- process validation. Forensic Sci Int 2020; 318:110560. [PMID: 33183864 DOI: 10.1016/j.forsciint.2020.110560] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 09/17/2020] [Accepted: 10/19/2020] [Indexed: 11/25/2022]
Abstract
Forensic application of 3D scanning and printing technology is gaining momentum with 3D printed evidence starting to be produced for court. However, the processes for creating these forensic 3D models requires still rigorous assessment to ensure they adhere to the relevant legal standards. Although, previous work has examined the accuracy of 3D prints created from medical grade Computed Tomography (CT), no such assessment has been carried out for Micro Computed Tomography (micro-CT) which offers superior resolution and the ability to capture forensically relevant injuries. This study aimed to quantify the error rates associated with forensic 3D printed models and toolmarks, created using three different printing technologies, based on micro-CT data. Overall, 3D printed models, based on micro-CT scans, replicate bone surface geometry to sub-millimetre accuracy (<0.62mm for overall shape and <0.36mm for toolmarks). However, there were significant differences between the printing technology employed (mean errors of -0.3%, -0.8%, and 0.7% for shape geometry and -0.8%, 14.1%, and 0.7% for toolmark geometry for Printers 1-3 respectively). Where possible, the authors recommend micro-CT imaging for producing forensic 3D printed bone models particularly when injuries are present.
Collapse
|