1
|
Singh S, Bianchi L, Korganbayev S, Namakshenas P, Melnik R, Saccomandi P. Non-Fourier Bioheat Transfer Analysis in Brain Tissue During Interstitial Laser Ablation: Analysis of Multiple Influential Factors. Ann Biomed Eng 2024; 52:967-981. [PMID: 38236341 PMCID: PMC11252202 DOI: 10.1007/s10439-023-03433-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 12/22/2023] [Indexed: 01/19/2024]
Abstract
This work presents the dual-phase lag-based non-Fourier bioheat transfer model of brain tissue subjected to interstitial laser ablation. The finite element method has been utilized to predict the brain tissue's temperature distributions and ablation volumes. A sensitivity analysis has been conducted to quantify the effect of variations in the input laser power, treatment time, laser fiber diameter, laser wavelength, and non-Fourier phase lags. Notably, in this work, the temperature-dependent thermal properties of brain tissue have been considered. The developed model has been validated by comparing the temperature obtained from the numerical and ex vivo brain tissue during interstitial laser ablation. The ex vivo brain model has been further extended to in vivo settings by incorporating the blood perfusion effects. The results of the systematic analysis highlight the importance of considering temperature-dependent thermal properties of the brain tissue, non-Fourier behavior, and microvascular perfusion effects in the computational models for accurate predictions of the treatment outcomes during interstitial laser ablation, thereby minimizing the damage to surrounding healthy tissue. The developed model and parametric analysis reported in this study would assist in a more accurate and precise prediction of the temperature distribution, thus allowing to optimize the thermal dosage during laser therapy in the brain.
Collapse
Affiliation(s)
- Sundeep Singh
- Faculty of Sustainable Design Engineering, University of Prince Edward Island, Charlottetown, PE, C1A 4P3, Canada
| | - Leonardo Bianchi
- Department of Mechanical Engineering, Politecnico di Milano, 20156, Milan, Italy
| | - Sanzhar Korganbayev
- Department of Mechanical Engineering, Politecnico di Milano, 20156, Milan, Italy
| | - Pouya Namakshenas
- Department of Mechanical Engineering, Politecnico di Milano, 20156, Milan, Italy
| | - Roderick Melnik
- MS2Discovery Interdisciplinary Research Institute, Wilfrid Laurier University, Waterloo, ON, Canada
| | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, 20156, Milan, Italy.
| |
Collapse
|
2
|
Park G, Woo S, Kim K, Kim J, Hwang J, Kim SK, Lee H, Lee S, Kwon B, Kim S, Rhee H, Kim W. Noninvasive and Continuous Monitoring of the Core Body Temperature through the Quantitative Measurement of Blood Perfusion Rate. ACS Sens 2023; 8:2975-2985. [PMID: 37432871 DOI: 10.1021/acssensors.3c00273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/13/2023]
Abstract
Core body temperature (CBT) is one of the four vital signs that must be monitored continuously. The continuous recording of CBT is possible through invasive methods by inserting a temperature probe into specific body sites. We report a novel method to monitor CBT through the quantitative measurement of skin blood perfusion rate (ωb,skin). By monitoring the skin temperature, heat flux, and ωb,skin, the arterial blood temperature, equivalent to CBT, can be extracted. ωb,skin is quantitatively evaluated thermally via sinusoidal heating with regulated thermal penetration depth so that the blood perfusion rate is acquired only in the skin. Its quantification is significant because it indicates various physiological events including hyper- or hypothermia, tissue death, and delineation of tumors. A subject showed promising results with steady values of ωb,skin and CBT of 5.2 ± 1.05 × 10-4 s-1 and 36.51 ± 0.23 °C, respectively. For periods where the subject's actual CBT (axillary temperature) did not fall within the estimated range, the average deviation from the actual CBT was only 0.07 °C. This study aims to develop a competent methodology capable of continuously monitoring the CBT and blood perfusion rate at a distant location from the core body region for the diagnosis of a patient's health condition with wearable devices.
Collapse
Affiliation(s)
- Gimin Park
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Seungjai Woo
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Kyomin Kim
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Jiyong Kim
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Junphil Hwang
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Sang Kyu Kim
- Samsung Advanced Institute of Technology (SAIT), Samsung Electronics Co., Ltd., Suwon 16678, Republic of Korea
| | - Hotaik Lee
- Samsung Advanced Institute of Technology (SAIT), Samsung Electronics Co., Ltd., Suwon 16678, Republic of Korea
| | - Soyoung Lee
- Samsung Advanced Institute of Technology (SAIT), Samsung Electronics Co., Ltd., Suwon 16678, Republic of Korea
| | - Boksoon Kwon
- Samsung Advanced Institute of Technology (SAIT), Samsung Electronics Co., Ltd., Suwon 16678, Republic of Korea
| | - Sungho Kim
- Samsung Advanced Institute of Technology (SAIT), Samsung Electronics Co., Ltd., Suwon 16678, Republic of Korea
| | - Hongsoon Rhee
- Samsung Advanced Institute of Technology (SAIT), Samsung Electronics Co., Ltd., Suwon 16678, Republic of Korea
| | - Woochul Kim
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| |
Collapse
|
3
|
Al-Lehaibi EAN. Mathematical Modelling with the Exact Solution of Three Different Bioheat Conduction Models of a Skin Tissue Shocked by Thermoelectrical Effect. Int J Biomater 2023; 2023:3863773. [PMID: 37492143 PMCID: PMC10365921 DOI: 10.1155/2023/3863773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 06/15/2023] [Accepted: 06/26/2023] [Indexed: 07/27/2023] Open
Abstract
This research deals with the temperature increment and responsiveness of skin tissue to a continuous flow of surface heat induced by a constant-voltage electrical current. The exact analytical solution for the dual-phase-lag (DPL) of bioheat transfer has been obtained. It is used to confine the variables to a limited domain to solve the governing equations. The transition temperature reactions have been measured and investigated. The figures provide a comparison of the Pennes, Tzou models, and Vernotte-Cattaneo models. The numerical results demonstrate the values of the voltage, resistance, electric shock time, and dual-phase-lag time parameters which have significant influences on the distributions of the dynamic and conductive temperature rise through the skin tissue.
Collapse
Affiliation(s)
- Eman A. N. Al-Lehaibi
- Mathematics Department, Al-Lith University College, Umm Al-Qura University, Al-Lith, Saudi Arabia
| |
Collapse
|
4
|
Zenkour AM, Saeed T, Aati AM. Refined Dual-Phase-Lag Theory for the 1D Behavior of Skin Tissue under Ramp-Type Heating. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2421. [PMID: 36984301 PMCID: PMC10055763 DOI: 10.3390/ma16062421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/15/2023] [Accepted: 03/15/2023] [Indexed: 06/18/2023]
Abstract
In this article, a mathematical analysis of thermoelastic skin tissue is presented based on a refined dual-phase-lag (DPL) thermal conduction theory that considers accounting for the effect of multiple time derivatives. The thin skin tissue is regarded as having mechanically clamped surfaces that are one-dimensional. Additionally, the skin tissue undergoes ramp-type heating on its outer surface, whereas its inner surface keeps the assessed temperature from vanishing. Some of the previous generalized thermoelasticity theories were obtained from the proposed model. The distributions of temperature, displacement, dilatation, and stress are attained by applying the Laplace transform and its numerical reversal approaches. The outcomes are explicitly illustrated to examine the significant influences on the distributions of the field variables. The refined DPL bioheat conduction model in this study predicts temperature, and the findings revealed that the model is located among the existing generalized thermoelastic theories. These findings offer a more thorough understanding of how skin tissue behaves when exposed to a particular boundary condition temperature distribution.
Collapse
Affiliation(s)
- Ashraf M. Zenkour
- Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- Department of Mathematics, Faculty of Science, Kafrelsheikh University, Kafrelsheikh 33516, Egypt
| | - Tareq Saeed
- Financial Mathematics and Actuarial Science (FMAS)-Research Group, Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Amal M. Aati
- Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- Department of Mathematics, College of Science and Arts and Applied College Branch in Rijal Alma’a, King Khalid University, Abha 61411, Saudi Arabia
| |
Collapse
|
5
|
Sobhy M, Zenkour AM. Refined Lord-Shulman Theory for 1D Response of Skin Tissue under Ramp-Type Heat. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6292. [PMID: 36143604 PMCID: PMC9505323 DOI: 10.3390/ma15186292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 08/25/2022] [Accepted: 09/08/2022] [Indexed: 06/16/2023]
Abstract
In this article, we present a mathematical model of thermoelastic skin tissue based on a refined Lord-Shulman heat conduction theory. A small thickness of skin tissue is considered to be one-dimensional with mechanical clamped surfaces. In addition, the skin tissue's outer surface is subjected to ramp-type heating while its inner surface is adiabatic. A simple Lord-Shulman theory, as well as the classical coupled thermoelasticity, are also applied in this article. Laplace transform techniques and their inversions are calculated to return to the time domain. Numerical outcomes are represented graphically to discuss the significant impacts on the temperature, dilatation, displacement, and stress distributions. Such results provide a more comprehensive and better insight for understanding the behavior of skin tissue during the temperature distribution of a specific boundary condition.
Collapse
Affiliation(s)
- Mohammed Sobhy
- Department of Mathematics and Statistics, College of Science, King Faisal University, P.O. Box 400, Al-Ahsa 31982, Saudi Arabia
- Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Ashraf M. Zenkour
- Department of Mathematics, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- Department of Mathematics, Faculty of Science, Kafrelsheikh University, Kafrelsheikh 33516, Egypt
| |
Collapse
|
6
|
Abstract
Significant research efforts have been devoted in the past decades to accurately modelling the complex heat transfer phenomena within biological tissues. These modeling efforts and analysis have assisted in a better understanding of the intricacies of associated biological phenomena and factors that affect the treatment outcomes of hyperthermic therapeutic procedures. In this contribution, we report a three-dimensional non-Fourier bio-heat transfer model of cardiac ablation that accounts for the three-phase-lags (TPL) in the heat propagation, viz., lags due to heat flux, temperature gradient, and thermal displacement gradient. Finite element-based COMSOL Multiphysics software has been utilized to predict the temperature distributions and ablation volumes. A comparative analysis has been conducted to report the variation in the treatment outcomes of cardiac ablation considering different bio-heat transfer models. The effect of variations in the magnitude of different phase lags has been systematically investigated. The fidelity and integrity of the developed model have been evaluated by comparing the results of the developed model with the analytical results of the recent studies available in the literature. This study demonstrates the importance of considering non-Fourier lags within biological tissue for predicting more accurately the characteristics important for the efficient application of thermal therapies.
Collapse
|