1
|
Stengl C, Panow K, Arbes E, Muñoz ID, Christensen JB, Neelsen C, Dinkel F, Weidner A, Runz A, Johnen W, Liermann J, Echner G, Vedelago J, Jäkel O. A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer. Phys Med Biol 2023; 68:245013. [PMID: 37918022 DOI: 10.1088/1361-6560/ad0902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 11/02/2023] [Indexed: 11/04/2023]
Abstract
Objective. Carbon ion radiotherapy is a promising radiation technique for malignancies like pancreatic cancer. However, organs' motion imposes challenges for achieving homogeneous dose delivery. In this study, an anthropomorphicPancreasPhantom forIon-beamTherapy (PPIeT) was developed to simulate breathing and gastrointestinal motion during radiotherapy.Approach. The developed phantom contains a pancreas, two kidneys, a duodenum, a spine and a spinal cord. The shell of the organs was 3D printed and filled with agarose-based mixtures. Hounsfield Units (HU) of PPIeTs' organs were measured by CT. The pancreas motion amplitude in cranial-caudal (CC) direction was evaluated from patients' 4D CT data. Motions within the obtained range were simulated and analyzed in PPIeT using MRI. Additionally, GI motion was mimicked by changing the volume of the duodenum and quantified by MRI. A patient-like treatment plan was calculated for carbon ions, and the phantom was irradiated in a static and moving condition. Dose measurements in the organs were performed using an ionization chamber and dosimetric films.Main results. PPIeT presented tissue equivalent HU and reproducible breathing-induced CC displacements of the pancreas between (3.98 ± 0.36) mm and a maximum of (18.19 ± 0.44) mm. The observed maximum change in distance of (14.28 ± 0.12) mm between pancreas and duodenum was consistent with findings in patients. Carbon ion irradiation revealed homogenous coverage of the virtual tumor at the pancreas in static condition with a 1% deviation from the treatment plan. Instead, the dose delivery during motion with the maximum amplitude yielded an underdosage of 21% at the target and an increased uncertainty by two orders of magnitude.Significance. A dedicated phantom was designed and developed for breathing motion assessment of dose deposition during carbon ion radiotherapy. PPIeT is a unique tool for dose verification in the pancreas and its organs at risk during end-to-end tests.
Collapse
Affiliation(s)
- Christina Stengl
- Medical Faculty Heidelberg, Heidelberg University, Im Neuenheimer Feld 672, Heidelberg D-69120, Germany
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Kathrin Panow
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Eric Arbes
- Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Department for Physics and Astronomy, Heidelberg University, Im Neuenheimer Feld 226, Heidelberg D-69120, Germany
| | - Iván D Muñoz
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department for Physics and Astronomy, Heidelberg University, Im Neuenheimer Feld 226, Heidelberg D-69120, Germany
| | - Jeppe B Christensen
- Department of Radiation Safety and Security, Paul Scherrer Institute (PSI), Forschungsstrasse 111, Villigen PSI 5232, Switzerland
| | - Christian Neelsen
- Department of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Department of Nuclear Medicine, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, Berlin D-10117, Germany
| | - Fabian Dinkel
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Artur Weidner
- Medical Faculty Heidelberg, Heidelberg University, Im Neuenheimer Feld 672, Heidelberg D-69120, Germany
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Armin Runz
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Wibke Johnen
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - Jakob Liermann
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital (UKHD), Im Neuenheimer Feld 400, Heidelberg D-69120, Germany
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital (UKHD), Im Neuenheimer Feld 450, Heidelberg D-69120, Germany
- National Center for Tumor Diseases (NCT), Im Neuenheimer Feld 460, D-69120 Heidelberg, Germany
| | - Gernot Echner
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
| | - José Vedelago
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital (UKHD), Im Neuenheimer Feld 400, Heidelberg D-69120, Germany
| | - Oliver Jäkel
- Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg D-69120, Germany
- Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany
- Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital (UKHD), Im Neuenheimer Feld 450, Heidelberg D-69120, Germany
| |
Collapse
|
2
|
Segami K, Espinoza Orías AA, Miyamoto H, Kanzaki K, An HS, Inoue N. Regional distribution of computed tomography attenuation across the lumbar endplate. PLoS One 2021; 16:e0259001. [PMID: 34705863 PMCID: PMC8550599 DOI: 10.1371/journal.pone.0259001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Accepted: 10/10/2021] [Indexed: 12/05/2022] Open
Abstract
The vertebral endplate forms a structural boundary between intervertebral disc and the trabecular bone of the vertebral body. As a mechanical interface between the stiff bone and resilient disc, the endplate is the weakest portion of the vertebral-disc complex and is predisposed to mechanical failure. However, the literature concerning the bone mineral density (BMD) distribution within the spinal endplate is comparatively sparse. The objective of this study is to investigate the three-dimensional (3D) distribution of computed tomography (CT) attenuation across the lumbosacral endplate measured in Hounsfield Units (HU). A total of 308 endplates from 28 cadaveric fresh-frozen lumbosacral spines were used in this study. Each spine was CT-scanned and the resulting DICOM data was used to obtain HU values of the bone endplate. Each individual endplate surface was subdivided into five clinically-relevant topographic zones. Attenuation was analyzed by spinal levels, sites (superior or inferior endplate) and endplate region. The highest HU values were found at the S1 endplate. Comparisons between the superior and inferior endplates showed the HU values in inferior endplates were significantly higher than those in the superior endplates within the same vertebra and the HU values in endplates cranial to the disc were significantly higher than those in the endplates caudal to the disc within the same disc. Attenuation in the peripheral region was significantly higher than in the central region by 32.5%. Regional comparison within the peripheral region showed the HU values in the posterior region were significantly higher than those in the anterior region and the HU values in the left region were significantly higher than those in the right region. This study provided detailed data on the regional HU distribution across the lumbosacral endplate, which can be useful to understand causes of some endplate lesions, such as fracture, and also to design interbody instrumentation.
Collapse
Affiliation(s)
- Kazuyuki Segami
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, United States of America
- Department of Orthopedic Surgery, Showa University Fujigaoka Hospital, Yokohama, Japan
| | - Alejandro A. Espinoza Orías
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, United States of America
| | - Hiroe Miyamoto
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, United States of America
| | - Koji Kanzaki
- Department of Orthopedic Surgery, Showa University Fujigaoka Hospital, Yokohama, Japan
| | - Howard S. An
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, United States of America
| | - Nozomu Inoue
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, United States of America
- * E-mail:
| |
Collapse
|