1
|
Francken N, Sanctorum J, Paramonov P, Sijbers J, De Beenhouwer J. Edge illumination x-ray phase contrast simulations using the CAD-ASTRA toolbox. OPTICS EXPRESS 2024; 32:10005-10021. [PMID: 38571213 DOI: 10.1364/oe.516138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 02/13/2024] [Indexed: 04/05/2024]
Abstract
Edge illumination x-ray phase contrast imaging (XPCI) provides increased contrast for low absorbing materials compared to attenuation images and sheds light on the material microstructure through dark field contrast. To apply XPCI in areas such as non-destructive testing and inline inspection, where scanned samples are increasingly compared to simulated reference images, accurate and efficient simulation software is required. However, currently available simulators rely on expensive Monte Carlo techniques or wave-optics frameworks, resulting in long simulation times. Furthermore, these simulators are often not optimized to work with computer-aided design (CAD) models, a common and memory-efficient method to represent manufactured objects, hindering their integration in an inspection pipeline. In this work, we address these shortcomings by introducing an edge illumination XPCI simulation framework built upon the recently developed CAD-ASTRA toolbox. CAD-ASTRA allows for the efficient simulation of x-ray projections from CAD models through GPU-accelerated ray tracing and supports ray refraction in a geometric optics framework. The edge illumination implementation is validated and its performance is benchmarked against GATE, a state-of-the-art Monte Carlo simulator, revealing a simulation speed increase of up to three orders of magnitude, while maintaining high accuracy in the resulting images.
Collapse
|
2
|
Savatović S, Zdora MC, De Marco F, Bikis C, Olbinado M, Rack A, Müller B, Thibault P, Zanette I. Multi-resolution X-ray phase-contrast and dark-field tomography of human cerebellum with near-field speckles. BIOMEDICAL OPTICS EXPRESS 2024; 15:142-161. [PMID: 38223169 PMCID: PMC10783905 DOI: 10.1364/boe.502664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/30/2023] [Accepted: 11/09/2023] [Indexed: 01/16/2024]
Abstract
In this study, we use synchrotron-based multi-modal X-ray tomography to examine human cerebellar tissue in three dimensions at two levels of spatial resolution (2.3 µm and 11.9 µm). We show that speckle-based imaging (SBI) produces results that are comparable to propagation-based imaging (PBI), a well-established phase-sensitive imaging method. The different SBI signals provide complementary information, which improves tissue differentiation. In particular, the dark-field signal aids in distinguishing tissues with similar average electron density but different microstructural variations. The setup's high resolution and the imaging technique's excellent phase sensitivity enabled the identification of different cellular layers and additionally, different cell types within these layers. We also correlated this high-resolution phase-contrast information with measured dark-field signal levels. These findings demonstrate the viability of SBI and the potential benefit of the dark-field modality for virtual histology of brain tissue.
Collapse
Affiliation(s)
- Sara Savatović
- Department of Physics, University of Trieste, Via Valerio 2, 34127 Trieste, Italy
- Elettra-Sincrotrone Trieste, Strada Statale 14 – km 163.5, 34149 Basovizza, Italy
| | - Marie-Christine Zdora
- Department of Biomedical Engineering, ETH Zürich, Gloriastrasse 35, 8092 Zürich, Switzerland
- Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen PSI, Switzerland
| | - Fabio De Marco
- Department of Physics, University of Trieste, Via Valerio 2, 34127 Trieste, Italy
- Elettra-Sincrotrone Trieste, Strada Statale 14 – km 163.5, 34149 Basovizza, Italy
| | - Christos Bikis
- Psychiatric Hospital in Winterthur, Wieshofstrasse 102, 8408 Winterthur, Switzerland
- Biomaterials Science Center, Department of Biomedical Engineering, University of Basel, Hegenheimermattweg 167 B/C, 4123 Allschwil, Switzerland
| | - Margie Olbinado
- Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen PSI, Switzerland
| | - Alexander Rack
- ESRF – The European Synchrotron, CS40220, CEDEX 09, 38043 Grenoble, France
| | - Bert Müller
- Biomaterials Science Center, Department of Biomedical Engineering, University of Basel, Hegenheimermattweg 167 B/C, 4123 Allschwil, Switzerland
| | - Pierre Thibault
- Department of Physics, University of Trieste, Via Valerio 2, 34127 Trieste, Italy
- Elettra-Sincrotrone Trieste, Strada Statale 14 – km 163.5, 34149 Basovizza, Italy
| | - Irene Zanette
- Elettra-Sincrotrone Trieste, Strada Statale 14 – km 163.5, 34149 Basovizza, Italy
| |
Collapse
|