1
|
Sulistyawan IGE, Nishimae D, Ishii T, Saijo Y. Singular value decomposition with weighting matrix applied for optical-resolution photoacoustic microscopes. ULTRASONICS 2024; 143:107424. [PMID: 39084109 DOI: 10.1016/j.ultras.2024.107424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 07/03/2024] [Accepted: 07/25/2024] [Indexed: 08/02/2024]
Abstract
The prestige target selectivity and imaging depth of optical-resolution photoacoustic microscope (OR-PAM) have gained attentions to enable advanced intra-cellular visualizations. However, the broad-band nature of photoacoustic signals is prone to noise and artifacts caused by the inefficient light-to-pressure translation, resulting in poor image quality. The present study foresees application of singular value decomposition (SVD) to effectively extract the photoacoustic signals from these noise and artifacts. Although spatiotemporal SVD succeeded in ultrasound flow signal extraction, the conventional multi frame model is not suitable for data acquired with scanning OR-PAM due to the burden of accessing multiple frames. To utilize SVD on the OR-PAM, this study began with exploring SVD applied on multiple A-lines of photoacoustic signal instead of frames. Upon explorations, an obstacle of uncertain presence of unwanted singular vectors was observed. To tackle this, a data-driven weighting matrix was designed to extract relevant singular vectors based on the analyses of temporal-spatial singular vectors. Evaluation on the extraction capability by the SVD with the weighting matrix showed a superior signal quality with efficient computation against past studies. In summary, this study contributes to the field by providing exploration of SVD applied on A-line signals as well as its practical utilization to distinguish and recover photoacoustic signals from noise and artifact components.
Collapse
Affiliation(s)
| | - Daisuke Nishimae
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
| | - Takuro Ishii
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan; Frontier Research Institute for Interdisciplinary Sciences, Tohoku University, Sendai, Japan.
| | - Yoshifumi Saijo
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan.
| |
Collapse
|
2
|
Suthya AR, Wong CHY, Bourne JH. Diving head-first into brain intravital microscopy. Front Immunol 2024; 15:1372996. [PMID: 38817606 PMCID: PMC11137164 DOI: 10.3389/fimmu.2024.1372996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 04/29/2024] [Indexed: 06/01/2024] Open
Abstract
Tissue microenvironments during physiology and pathology are highly complex, meaning dynamic cellular activities and their interactions cannot be accurately modelled ex vivo or in vitro. In particular, tissue-specific resident cells which may function and behave differently after isolation and the heterogenous vascular beds in various organs highlight the importance of observing such processes in real-time in vivo. This challenge gave rise to intravital microscopy (IVM), which was discovered over two centuries ago. From the very early techniques of low-optical resolution brightfield microscopy, limited to transparent tissues, IVM techniques have significantly evolved in recent years. Combined with improved animal surgical preparations, modern IVM technologies have achieved significantly higher speed of image acquisition and enhanced image resolution which allow for the visualisation of biological activities within a wider variety of tissue beds. These advancements have dramatically expanded our understanding in cell migration and function, especially in organs which are not easily accessible, such as the brain. In this review, we will discuss the application of rodent IVM in neurobiology in health and disease. In particular, we will outline the capability and limitations of emerging technologies, including photoacoustic, two- and three-photon imaging for brain IVM. In addition, we will discuss the use of these technologies in the context of neuroinflammation.
Collapse
|
3
|
Jiang D, Zhu L, Tong S, Shen Y, Gao F, Gao F. Photoacoustic imaging plus X: a review. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S11513. [PMID: 38156064 PMCID: PMC10753847 DOI: 10.1117/1.jbo.29.s1.s11513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 11/14/2023] [Accepted: 12/11/2023] [Indexed: 12/30/2023]
Abstract
Significance Photoacoustic (PA) imaging (PAI) represents an emerging modality within the realm of biomedical imaging technology. It seamlessly blends the wealth of optical contrast with the remarkable depth of penetration offered by ultrasound. These distinctive features of PAI hold tremendous potential for various applications, including early cancer detection, functional imaging, hybrid imaging, monitoring ablation therapy, and providing guidance during surgical procedures. The synergy between PAI and other cutting-edge technologies not only enhances its capabilities but also propels it toward broader clinical applicability. Aim The integration of PAI with advanced technology for PA signal detection, signal processing, image reconstruction, hybrid imaging, and clinical applications has significantly bolstered the capabilities of PAI. This review endeavor contributes to a deeper comprehension of how the synergy between PAI and other advanced technologies can lead to improved applications. Approach An examination of the evolving research frontiers in PAI, integrated with other advanced technologies, reveals six key categories named "PAI plus X." These categories encompass a range of topics, including but not limited to PAI plus treatment, PAI plus circuits design, PAI plus accurate positioning system, PAI plus fast scanning systems, PAI plus ultrasound sensors, PAI plus advanced laser sources, PAI plus deep learning, and PAI plus other imaging modalities. Results After conducting a comprehensive review of the existing literature and research on PAI integrated with other technologies, various proposals have emerged to advance the development of PAI plus X. These proposals aim to enhance system hardware, improve imaging quality, and address clinical challenges effectively. Conclusions The progression of innovative and sophisticated approaches within each category of PAI plus X is positioned to drive significant advancements in both the development of PAI technology and its clinical applications. Furthermore, PAI not only has the potential to integrate with the above-mentioned technologies but also to broaden its applications even further.
Collapse
Affiliation(s)
- Daohuai Jiang
- ShanghaiTech University, School of Information Science and Technology, Shanghai, China
- Fujian Normal University, College of Photonic and Electronic Engineering, Fuzhou, China
| | - Luyao Zhu
- ShanghaiTech University, School of Information Science and Technology, Shanghai, China
| | - Shangqing Tong
- ShanghaiTech University, School of Information Science and Technology, Shanghai, China
| | - Yuting Shen
- ShanghaiTech University, School of Information Science and Technology, Shanghai, China
| | - Feng Gao
- ShanghaiTech University, School of Information Science and Technology, Shanghai, China
| | - Fei Gao
- ShanghaiTech University, School of Information Science and Technology, Shanghai, China
- Shanghai Engineering Research Center of Energy Efficient and Custom AI IC, Shanghai, China
- Shanghai Clinical Research and Trial Center, Shanghai, China
| |
Collapse
|
4
|
Christie LB, Zheng W, Johnson W, Marecki EK, Heidrich J, Xia J, Oh KW. Review of imaging test phantoms. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:080903. [PMID: 37614568 PMCID: PMC10442662 DOI: 10.1117/1.jbo.28.8.080903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 07/31/2023] [Accepted: 08/04/2023] [Indexed: 08/25/2023]
Abstract
Significance Photoacoustic tomography has emerged as a prominent medical imaging technique that leverages its hybrid nature to provide deep penetration, high resolution, and exceptional optical contrast with notable applications in early cancer detection, functional brain imaging, drug delivery monitoring, and guiding interventional procedures. Test phantoms are pivotal in accelerating technology development and commercialization, specifically in photoacoustic (PA) imaging, and can be optimized to achieve significant advancements in PA imaging capabilities. Aim The analysis of material properties, structural characteristics, and manufacturing methodologies of test phantoms from existing imaging technologies provides valuable insights into their applicability to PA imaging. This investigation enables a deeper understanding of how phantoms can be effectively employed in the context of PA imaging. Approach Three primary categories of test phantoms (simple, intermediate, and advanced) have been developed to differentiate complexity and manufacturing requirements. In addition, four sub-categories (tube/channel, block, test target, and naturally occurring phantoms) have been identified to encompass the structural variations within these categories, resulting in a comprehensive classification system for test phantoms. Results Based on a thorough examination of literature and studies on phantoms in various imaging modalities, proposals have been put forth for the development of multiple PA-capable phantoms, encompassing considerations related to the material composition, structural design, and specific applications within each sub-category. Conclusions The advancement of novel and sophisticated test phantoms within each sub-category is poised to foster substantial progress in both the commercialization and development of PA imaging. Moreover, the continued refinement of test phantoms will enable the exploration of new applications and use cases for PA imaging.
Collapse
Affiliation(s)
- Liam B. Christie
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Wenhan Zheng
- State University of New York at Buffalo, Optical and Ultrasonic Imaging Laboratory, Biomedical Engineering, Buffalo, New York, United States
| | - William Johnson
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Eric K. Marecki
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - James Heidrich
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Jun Xia
- State University of New York at Buffalo, Optical and Ultrasonic Imaging Laboratory, Biomedical Engineering, Buffalo, New York, United States
| | - Kwang W. Oh
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| |
Collapse
|
5
|
Park B, Oh D, Kim J, Kim C. Functional photoacoustic imaging: from nano- and micro- to macro-scale. NANO CONVERGENCE 2023; 10:29. [PMID: 37335405 PMCID: PMC10279631 DOI: 10.1186/s40580-023-00377-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 05/24/2023] [Indexed: 06/21/2023]
Abstract
Functional photoacoustic imaging is a promising biological imaging technique that offers such unique benefits as scalable resolution and imaging depth, as well as the ability to provide functional information. At nanoscale, photoacoustic imaging has provided super-resolution images of the surface light absorption characteristics of materials and of single organelles in cells. At the microscopic and macroscopic scales. photoacoustic imaging techniques have precisely measured and quantified various physiological parameters, such as oxygen saturation, vessel morphology, blood flow, and the metabolic rate of oxygen, in both human and animal subjects. This comprehensive review provides an overview of functional photoacoustic imaging across multiple scales, from nano to macro, and highlights recent advances in technology developments and applications. Finally, the review surveys the future prospects of functional photoacoustic imaging in the biomedical field.
Collapse
Affiliation(s)
- Byullee Park
- Departments of Convergence IT Engineering, Mechanical Engineering, and Electrical Engineering, School of Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), Pohang, 37673, Republic of Korea
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
- Department of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Donghyeon Oh
- Departments of Convergence IT Engineering, Mechanical Engineering, and Electrical Engineering, School of Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), Pohang, 37673, Republic of Korea
| | - Jeesu Kim
- Departments of Cogno-Mechatronics Engineering and Optics and Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan, 46241, Republic of Korea.
| | - Chulhong Kim
- Departments of Convergence IT Engineering, Mechanical Engineering, and Electrical Engineering, School of Interdisciplinary Bioscience and Bioengineering, Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), Pohang, 37673, Republic of Korea.
| |
Collapse
|
6
|
Ahn J, Baik JW, Kim D, Choi K, Lee S, Park SM, Kim JY, Nam SH, Kim C. In vivo photoacoustic monitoring of vasoconstriction induced by acute hyperglycemia. PHOTOACOUSTICS 2023; 30:100485. [PMID: 37082618 PMCID: PMC10112177 DOI: 10.1016/j.pacs.2023.100485] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 03/19/2023] [Accepted: 03/29/2023] [Indexed: 05/03/2023]
Abstract
Postprandial hyperglycemia, blood glucose spikes, induces endothelial dysfunction, increasing cardiovascular risks. Endothelial dysfunction leads to vasoconstriction, and observation of this phenomenon is important for understanding acute hyperglycemia. However, high-resolution imaging of microvessels during acute hyperglycemia has not been fully developed. Here, we demonstrate that photoacoustic microscopy can noninvasively monitor morphological changes in blood vessels of live animals' extremities when blood glucose rises rapidly. As blood glucose level rose from 100 to 400 mg/dL following intraperitoneal glucose injection, heart/breath rate, and body temperature remained constant, but arterioles constricted by approximately -5.7 ± 1.1% within 20 min, and gradually recovered for another 40 min. In contrast, venular diameters remained within about 0.6 ± 1.5% during arteriolar constriction. Our results experimentally and statistically demonstrate that acute hyperglycemia produces transitory vasoconstriction in arterioles, with an opposite trend of change in blood glucose. These findings could help understanding vascular glucose homeostasis and the relationship between diabetes and cardiovascular diseases.
Collapse
Affiliation(s)
- Joongho Ahn
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, and Medical Device Innovation Center, Pohang University of Science and Technology, Pohang 37673, Republic of Korea
| | - Jin Woo Baik
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, and Medical Device Innovation Center, Pohang University of Science and Technology, Pohang 37673, Republic of Korea
| | - Donggyu Kim
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, and Medical Device Innovation Center, Pohang University of Science and Technology, Pohang 37673, Republic of Korea
| | - Karam Choi
- Samsung Advanced Institute of Technology, Samsung Electronics Co. Ltd., Suwon 16678, Republic of Korea
| | - Seunghyun Lee
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, and Medical Device Innovation Center, Pohang University of Science and Technology, Pohang 37673, Republic of Korea
| | - Sung-Min Park
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, and Medical Device Innovation Center, Pohang University of Science and Technology, Pohang 37673, Republic of Korea
| | - Jin Young Kim
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, and Medical Device Innovation Center, Pohang University of Science and Technology, Pohang 37673, Republic of Korea
| | - Sung Hyun Nam
- Samsung Advanced Institute of Technology, Samsung Electronics Co. Ltd., Suwon 16678, Republic of Korea
- Corresponding authors.
| | - Chulhong Kim
- Departments of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, and Medical Device Innovation Center, Pohang University of Science and Technology, Pohang 37673, Republic of Korea
- Corresponding authors.
| |
Collapse
|