1
|
Joshi IM, Mansouri M, Ahmed A, De Silva D, Simon RA, Esmaili P, Desa DE, Elias TM, Brown EB, Abhyankar VV. Microengineering 3D Collagen Matrices with Tumor-Mimetic Gradients in Fiber Alignment. ADVANCED FUNCTIONAL MATERIALS 2024; 34:2308071. [PMID: 38706986 PMCID: PMC11067715 DOI: 10.1002/adfm.202308071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Indexed: 05/07/2024]
Abstract
Collagen fibers in the 3D tumor microenvironment (TME) exhibit complex alignment landscapes that are critical in directing cell migration through a process called contact guidance. Previous in vitro work studying this phenomenon has focused on quantifying cell responses in uniformly aligned environments. However, the TME also features short-range gradients in fiber alignment that result from cell-induced traction forces. Although the influence of graded biophysical taxis cues is well established, cell responses to physiological alignment gradients remain largely unexplored. In this work, fiber alignment gradients in biopsy samples are characterized and recreated using a new microfluidic biofabrication technique to achieve tunable sub-millimeter to millimeter scale gradients. This study represents the first successful engineering of continuous alignment gradients in soft, natural biomaterials. Migration experiments on graded alignment show that HUVECs exhibit increased directionality, persistence, and speed compared to uniform and unaligned fiber architectures. Similarly, patterned MDA-MB-231 aggregates exhibit biased migration toward increasing fiber alignment, suggesting a role for alignment gradients as a taxis cue. This user-friendly approach, requiring no specialized equipment, is anticipated to offer new insights into the biophysical cues that cells interpret as they traverse the extracellular matrix, with broad applicability in healthy and diseased tissue environments.
Collapse
Affiliation(s)
- Indranil M. Joshi
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Mehran Mansouri
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Adeel Ahmed
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Dinindu De Silva
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Richard A. Simon
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Poorya Esmaili
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Danielle E. Desa
- Department of Biomedical Engineering, University of Rochester, Rochester, NY
| | - Tresa M. Elias
- Department of Biomedical Engineering, University of Rochester, Rochester, NY
| | - Edward B. Brown
- Department of Biomedical Engineering, University of Rochester, Rochester, NY
| | - Vinay V. Abhyankar
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| |
Collapse
|
2
|
Mansouri M, Hughes AR, Audi LA, Carter AE, Vidas JA, McGrath JL, Abhyankar VV. Transforming Static Barrier Tissue Models into Dynamic Microphysiological Systems. J Vis Exp 2024:10.3791/66090. [PMID: 38436378 PMCID: PMC11096840 DOI: 10.3791/66090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2024] Open
Abstract
Microphysiological systems are miniaturized cell culture platforms used to mimic the structure and function of human tissues in a laboratory setting. However, these platforms have not gained widespread adoption in bioscience laboratories where open-well, membrane-based approaches serve as the gold standard for mimicking tissue barriers, despite lacking fluid flow capabilities. This issue can be primarily attributed to the incompatibility of existing microphysiological systems with standard protocols and tools developed for open-well systems. Here, we present a protocol for creating a reconfigurable membrane-based platform with an open-well structure, flow enhancement capability, and compatibility with conventional protocols. This system utilizes a magnetic assembly approach that enables reversible switching between open-well and microfluidic modes. With this approach, users have the flexibility to begin an experiment in the open-well format using standard protocols and add or remove flow capabilities as needed. To demonstrate the practical usage of this system and its compatibility with standard techniques, an endothelial cell monolayer was established in an open-well format. The system was reconfigured to introduce fluid flow and then switched to the open-well format to conduct immunostaining and RNA extraction. Due to its compatibility with conventional open-well protocols and flow enhancement capability, this reconfigurable design is expected to be adopted by both engineering and bioscience laboratories.
Collapse
Affiliation(s)
- Mehran Mansouri
- Department of Biomedical Engineering, Rochester Institute of Technology
| | - Aidan R Hughes
- Department of Biomedical Engineering, Rochester Institute of Technology
| | - Lauren A Audi
- Department of Biomedical Engineering, Rochester Institute of Technology
| | - Anna E Carter
- Department of Biomedical Engineering, Rochester Institute of Technology
| | - Justin A Vidas
- Department of Biomedical Engineering, Rochester Institute of Technology
| | - James L McGrath
- Department of Biomedical Engineering, University of Rochester
| | - Vinay V Abhyankar
- Department of Biomedical Engineering, Rochester Institute of Technology;
| |
Collapse
|
3
|
Poskus MD, Wang T, Deng Y, Borcherding S, Atkinson J, Zervantonakis IK. Fabrication of 3D-printed molds for polydimethylsiloxane-based microfluidic devices using a liquid crystal display-based vat photopolymerization process: printing quality, drug response and 3D invasion cell culture assays. MICROSYSTEMS & NANOENGINEERING 2023; 9:140. [PMID: 37954040 PMCID: PMC10632127 DOI: 10.1038/s41378-023-00607-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 08/10/2023] [Accepted: 09/11/2023] [Indexed: 11/14/2023]
Abstract
Microfluidic platforms enable more precise control of biological stimuli and environment dimensionality than conventional macroscale cell-based assays; however, long fabrication times and high-cost specialized equipment limit the widespread adoption of microfluidic technologies. Recent improvements in vat photopolymerization three-dimensional (3D) printing technologies such as liquid crystal display (LCD) printing offer rapid prototyping and a cost-effective solution to microfluidic fabrication. Limited information is available about how 3D printing parameters and resin cytocompatibility impact the performance of 3D-printed molds for the fabrication of polydimethylsiloxane (PDMS)-based microfluidic platforms for cellular studies. Using a low-cost, commercially available LCD-based 3D printer, we assessed the cytocompatibility of several resins, optimized fabrication parameters, and characterized the minimum feature size. We evaluated the response to both cytotoxic chemotherapy and targeted kinase therapies in microfluidic devices fabricated using our 3D-printed molds and demonstrated the establishment of flow-based concentration gradients. Furthermore, we monitored real-time cancer cell and fibroblast migration in a 3D matrix environment that was dependent on environmental signals. These results demonstrate how vat photopolymerization LCD-based fabrication can accelerate the prototyping of microfluidic platforms with increased accessibility and resolution for PDMS-based cell culture assays.
Collapse
Affiliation(s)
- Matthew D. Poskus
- Department of Bioengineering, UPMC Hillman Cancer Center, University of Pittsburgh, Pittsburgh, PA USA
| | - Tuo Wang
- Department of Bioengineering, UPMC Hillman Cancer Center, University of Pittsburgh, Pittsburgh, PA USA
| | - Yuxuan Deng
- Department of Bioengineering, UPMC Hillman Cancer Center, University of Pittsburgh, Pittsburgh, PA USA
| | - Sydney Borcherding
- Department of Bioengineering, UPMC Hillman Cancer Center, University of Pittsburgh, Pittsburgh, PA USA
| | - Jake Atkinson
- Department of Bioengineering, UPMC Hillman Cancer Center, University of Pittsburgh, Pittsburgh, PA USA
| | - Ioannis K. Zervantonakis
- Department of Bioengineering, UPMC Hillman Cancer Center, University of Pittsburgh, Pittsburgh, PA USA
- McGowan Institute of Regenerative Medicine, Pittsburgh, PA USA
| |
Collapse
|
4
|
Kabir ME, Kim SJ. Method to fabricate round cross-sectional channel using thermal expansion of air for passive flow regulators. Electrophoresis 2023; 44:1698-1703. [PMID: 37650251 DOI: 10.1002/elps.202300101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 08/09/2023] [Accepted: 08/15/2023] [Indexed: 09/01/2023]
Abstract
We present a novel method for fabricating round cross-sectional channels for autoregulatory pressure regulators. The application of previously reported methods in multilayered soft lithography using three-dimensional printed molds is challenging. Herein, we used a thermal expansion technique to create round cross-sectional channels in replica layers using air in the cavity space of a master mold. The width and height of the round channel in the replica could be adjusted in the range of 80-300 and 3-57 µm, respectively, by varying the precuring time of the replica in the gel state and adjusting the cavity size of the master mold. We successfully fabricated a pressure regulator with a round cross-sectional channel, achieving a constant output pressure at a low threshold input pressure. Our device exhibited superior performance, with a constant output pressure at a threshold input pressure of less than 77%, compared to a device with a rectangular cross-sectional channel. Our method has significant potential for application in the fabrication of integrated microfluidic systems with round cross-sectional channels.
Collapse
Affiliation(s)
- Md Emamul Kabir
- Department of Mechanical Engineering, Konkuk University, Seoul, Republic of Korea
| | - Sung-Jin Kim
- Department of Mechanical Engineering, Konkuk University, Seoul, Republic of Korea
| |
Collapse
|
5
|
Joshi IM, Mansouri M, Ahmed A, Simon RA, Bambizi PE, Desa DE, Elias TM, Brown EB, Abhyankar VV. Microengineering 3D Collagen Matrices with Tumor-Mimetic Gradients in Fiber Alignment. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.07.09.548253. [PMID: 37502844 PMCID: PMC10369918 DOI: 10.1101/2023.07.09.548253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
In the tumor microenvironment (TME), collagen fibers facilitate tumor cell migration through the extracellular matrix. Previous studies have focused on studying the responses of cells on uniformly aligned or randomly aligned collagen fibers. However, the in vivo environment also features spatial gradients in alignment, which arise from the local reorganization of the matrix architecture due to cell-induced traction forces. Although there has been extensive research on how cells respond to graded biophysical cues, such as stiffness, porosity, and ligand density, the cellular responses to physiological fiber alignment gradients have been largely unexplored. This is due, in part, to a lack of robust experimental techniques to create controlled alignment gradients in natural materials. In this study, we image tumor biopsy samples and characterize the alignment gradients present in the TME. To replicate physiological gradients, we introduce a first-of-its-kind biofabrication technique that utilizes a microfluidic channel with constricting and expanding geometry to engineer 3D collagen hydrogels with tunable fiber alignment gradients that range from sub-millimeter to millimeter length scales. Our modular approach allows easy access to the microengineered gradient gels, and we demonstrate that HUVECs migrate in response to the fiber architecture. We provide preliminary evidence suggesting that MDA-MB-231 cell aggregates, patterned onto a specific location on the alignment gradient, exhibit preferential migration towards increasing alignment. This finding suggests that alignment gradients could serve as an additional taxis cue in the ECM. Importantly, our study represents the first successful engineering of continuous gradients of fiber alignment in soft, natural materials. We anticipate that our user-friendly platform, which needs no specialized equipment, will offer new experimental capabilities to study the impact of fiber-based contact guidance on directed cell migration.
Collapse
Affiliation(s)
- Indranil M. Joshi
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Mehran Mansouri
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Adeel Ahmed
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | - Richard A. Simon
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| | | | - Danielle E. Desa
- Department of Biomedical Engineering, University of Rochester, Rochester, NY
| | - Tresa M. Elias
- Department of Biomedical Engineering, University of Rochester, Rochester, NY
| | - Edward B. Brown
- Department of Biomedical Engineering, University of Rochester, Rochester, NY
| | - Vinay V. Abhyankar
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY
| |
Collapse
|
6
|
Musgrove HB, Saleheen A, Zatorski JM, Arneja A, Luckey CJ, Pompano RR. A Scalable, Modular Degasser for Passive In-Line Removal of Bubbles from Biomicrofluidic Devices. MICROMACHINES 2023; 14:435. [PMID: 36838135 PMCID: PMC9964747 DOI: 10.3390/mi14020435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/01/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Bubbles are a common cause of microfluidic malfunction, as they can perturb the fluid flow within the micro-sized features of a device. Since gas bubbles form easily within warm cell culture reagents, degassing is often necessary for biomicrofluidic systems. However, fabrication of a microscale degasser that can be used modularly with pre-existing chips may be cumbersome or challenging, especially for labs not equipped for traditional microfabrication, and current commercial options can be expensive. Here, we address the need for an affordable, accessible bubble trap that can be used in-line for continuous perfusion of organs-on-chip and other microfluidic cultures. We converted a previously described, manually fabricated PDMS degasser to allow scaled up, reproducible manufacturing by commercial machining or fused deposition modeling (FDM) 3D printing. After optimization, the machined and 3D printed degassers were found to be stable for >2 weeks under constant perfusion, without leaks. With a ~140 µL chamber volume, trapping capacity was extrapolated to allow for ~5-20 weeks of degassing depending on the rate of bubble formation. The degassers were biocompatible for use with cell culture, and they successfully prevented bubbles from reaching a downstream microfluidic device. Both degasser materials showed little to no leaching. The machined degasser did not absorb reagents, while the FDM printed degasser absorbed a small amount, and both maintained fluidic integrity from 1 µL/min to >1 mL/min of pressure-driven flow. Thus, these degassers can be fabricated in bulk and allow for long-term, efficient bubble removal in a simple microfluidic perfusion set-up.
Collapse
Affiliation(s)
- Hannah B. Musgrove
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | - Amirus Saleheen
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | | | - Abhinav Arneja
- Department of Pathology, University of Virginia School of Medicine, Charlottesville, VA 22904, USA
| | - Chance John Luckey
- Department of Pathology, University of Virginia School of Medicine, Charlottesville, VA 22904, USA
| | - Rebecca R. Pompano
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| |
Collapse
|
7
|
Mansouri M, Ahmed A, Ahmad SD, McCloskey MC, Joshi IM, Gaborski TR, Waugh RE, McGrath JL, Day SW, Abhyankar VV. The Modular µSiM Reconfigured: Integration of Microfluidic Capabilities to Study In Vitro Barrier Tissue Models under Flow. Adv Healthc Mater 2022; 11:e2200802. [PMID: 35953453 PMCID: PMC9798530 DOI: 10.1002/adhm.202200802] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 08/01/2022] [Indexed: 01/28/2023]
Abstract
Microfluidic tissue barrier models have emerged to address the lack of physiological fluid flow in conventional "open-well" Transwell-like devices. However, microfluidic techniques have not achieved widespread usage in bioscience laboratories because they are not fully compatible with traditional experimental protocols. To advance barrier tissue research, there is a need for a platform that combines the key advantages of both conventional open-well and microfluidic systems. Here, a plug-and-play flow module is developed to introduce on-demand microfluidic flow capabilities to an open-well device that features a nanoporous membrane and live-cell imaging capabilities. The magnetic latching assembly of this design enables bi-directional reconfiguration and allows users to conduct an experiment in an open-well format with established protocols and then add or remove microfluidic capabilities as desired. This work also provides an experimentally-validated flow model to select flow conditions based on the experimental needs. As a proof-of-concept, flow-induced alignment of endothelial cells and the expression of shear-sensitive gene targets are demonstrated, and the different phases of neutrophil transmigration across a chemically stimulated endothelial monolayer under flow conditions are visualized. With these experimental capabilities, it is anticipated that both engineering and bioscience laboratories will adopt this reconfigurable design due to the compatibility with standard open-well protocols.
Collapse
Affiliation(s)
- Mehran Mansouri
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| | - Adeel Ahmed
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| | - S. Danial Ahmad
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - Molly C. McCloskey
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - Indranil M. Joshi
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| | - Thomas R. Gaborski
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| | - Richard E. Waugh
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - James L. McGrath
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
| | - Steven W. Day
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| | - Vinay V. Abhyankar
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, 14623, USA
| |
Collapse
|
8
|
Ahmed A, Joshi IM, Goulet MR, Vidas JA, Byerley AM, Mansouri M, Day SW, Abhyankar VV. Microengineering 3D Collagen Hydrogels with Long-Range Fiber Alignment. J Vis Exp 2022:10.3791/64457. [PMID: 36156068 PMCID: PMC10203374 DOI: 10.3791/64457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Aligned collagen I (COL1) fibers guide tumor cell motility, influence endothelial cell morphology, control stem cell differentiation, and are a hallmark of cardiac and musculoskeletal tissues. To study cell response to aligned microenvironments in vitro, several protocols have been developed to generate COL1 matrices with defined fiber alignment, including magnetic, mechanical, cell-based, and microfluidic methods. Of these, microfluidic approaches offer advanced capabilities such as accurate control over fluid flows and the cellular microenvironment. However, the microfluidic approaches to generate aligned COL1 matrices for advanced in vitro culture platforms have been limited to thin "mats" (<40 µm in thickness) of COL1 fibers that extend over distances less than 500 µm and are not conducive to 3D cell culture applications. Here, we present a protocol to fabricate 3D COL1 matrices (130-250 µm in thickness) with millimeter-scale regions of defined fiber alignment in a microfluidic device. This platform provides advanced cell culture capabilities to model structured tissue microenvironments by providing direct access to the micro-engineered matrix for cell culture.
Collapse
Affiliation(s)
- Adeel Ahmed
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology
| | - Indranil M Joshi
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology
| | - Madeleine R Goulet
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology
| | - Justin A Vidas
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology
| | - Ann M Byerley
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology
| | - Mehran Mansouri
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology
| | - Steven W Day
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology
| | - Vinay V Abhyankar
- Department of Biomedical Engineering, Kate Gleason College of Engineering, Rochester Institute of Technology;
| |
Collapse
|