1
|
Jiang KP, Bennett S, Heiniger EK, Kumar S, Yager P. UbiNAAT: a multiplexed point-of-care nucleic acid diagnostic platform for rapid at-home pathogen detection. LAB ON A CHIP 2024; 24:492-504. [PMID: 38164805 DOI: 10.1039/d3lc00753g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
The COVID-19 pandemic increased demands for respiratory disease testing to facilitate treatment and limit transmission, demonstrating in the process that most existing test options were too complex and expensive to perform in point-of-care or home scenarios. Lab-based molecular techniques can detect viral RNA in respiratory illnesses but are expensive and require trained personnel, while affordable antigen-based home tests lack sensitivity for early detection in newly infected or asymptomatic individuals. The few home RNA detection tests deployed were prohibitively expensive. Here, we demonstrate a point-of-care, paper-based rapid analysis device that simultaneously detects multiple viral RNAs; it is demonstrated on two common respiratory viruses (COVID-19 and influenza A) spiked onto a commercial nasal swab. The automated device requires no sample preparation by the user after insertion of the swab, minimizing user operation steps. We incorporated lyophilized amplification reagents immobilized in a porous matrix, a novel thermally actuated valve for multiplexed fluidic control, a printed circuit board that performs on-device lysis and amplification within a cell-phone-sized disposable device. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) products are visualized via fluorescent dyes using a modified cell phone, resulting in detection of as few as 104 viral copies per swab across both pathogens within 30 minutes. This integrated platform could be commercialized in a form that would be inexpensive, portable, and sensitive; it can readily be multiplexed to detect as many as 8 different RNA or DNA sequences, and adapted to any desired RNA or DNA detection assays.
Collapse
Affiliation(s)
- Kevin P Jiang
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA.
| | - Steven Bennett
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA.
| | - Erin K Heiniger
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA.
| | - Sujatha Kumar
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA.
| | - Paul Yager
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA.
| |
Collapse
|
2
|
Sritong N, Ngo WW, Ejendal KFK, Linnes JC. Development of an integrated sample amplification control for salivary point-of-care pathogen testing. Anal Chim Acta 2024; 1287:342072. [PMID: 38182338 DOI: 10.1016/j.aca.2023.342072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 11/20/2023] [Accepted: 11/25/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND The COVID-19 pandemic has led to a rise in point-of-care (POC) and home-based tests, but concerns over usability, accuracy, and effectiveness have arisen. The incorporation of internal amplification controls (IACs), essential control for translational POC diagnostics, could mitigate false-negative and false-positive results due to sample matrix interference or inhibition. Although emerging POC nucleic acid amplification tests (NAATs) for detecting SARS-CoV-2 show impressive analytical sensitivity in the lab, the assessment of clinical accuracy with IACs is often overlooked. In some cases, the IACs were run spatially, complicating assay workflow. Therefore, the multiplex assay for pathogen and IAC is needed. RESULTS We developed a one-pot duplex reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for saliva samples, a non-invasive and simple collected specimen for POC NAATs. The ORF1ab gene of SARS-CoV-2 was used as a target and a human 18S ribosomal RNA in human saliva was employed as an IAC to ensure clinical reliability of the RT-LAMP assay. The optimized assay could detect SARS-CoV-2 viral particles down to 100 copies/μL of saliva within 30 min without RNA extraction. The duplex RT-LAMP for SARS-CoV-2 and IAC is successfully amplified in the same reaction without cross-reactivity. The valid results were easily visualized in triple-line lateral flow immunoassay, in which two lines (flow control and IAC lines) represent valid negative results and three lines (flow control, IAC, and test line) represent valid positive results. This duplex assay demonstrated a clinical sensitivity of 95%, specificity of 100%, and accuracy of 96% in 30 clinical saliva samples. SIGNIFICANCE IACs play a crucial role in ensuring user confidence with respect to the accuracy and reliability of at-home and POC molecular diagnostics. We demonstrated the multiplex capability of SARS-COV-2 and human18S ribosomal RNA RT-LAMP without complicating assay design. This generic platform can be extended in a similar manner to include human18S ribosomal RNA IACs into different clinical sample matrices.
Collapse
Affiliation(s)
- Navaporn Sritong
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Winston Wei Ngo
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Karin F K Ejendal
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Jacqueline C Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA; Department of Public Health, Purdue University, West Lafayette, IN, USA.
| |
Collapse
|
3
|
Sritong N, Ngo WW, Ejendal KFK, Linnes JC. Development of an Integrated Sample Amplification Control for Salivary Point-of-Care Pathogen Testing. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.10.03.23296477. [PMID: 37873363 PMCID: PMC10593008 DOI: 10.1101/2023.10.03.23296477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
Background The COVID-19 pandemic has led to a rise in point-of-care (POC) and home-based tests, but concerns over usability, accuracy, and effectiveness have arisen. The incorporation of internal amplification controls (IACs), essential control for translational POC diagnostics, could mitigate false-negative and false-positive results due to sample matrix interference or inhibition. Although emerging POC nucleic acid amplification tests (NAATs) for detecting SARS-CoV-2 show impressive analytical sensitivity in the lab, the assessment of clinical accuracy with IACs is often overlooked. In some cases, the IACs were run spatially, complicating assay workflow. Therefore, the multiplex assay for pathogen and IAC is needed. Results We developed a one-pot duplex reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for saliva samples, a non-invasive and simple collected specimen for POC NAATs. The ORF1ab gene of SARS-CoV-2 was used as a target and a human 18S ribosomal RNA in human saliva was employed as an IAC to ensure clinical reliability of the RT-LAMP assay. The optimized assay could detect SARS-CoV-2 viral particles down to 100 copies/μL of saliva within 30 minutes without RNA extraction. The duplex RT-LAMP for SARS-CoV-2 and IAC is successfully amplified in the same reaction without cross-reactivity. The valid results were easily visualized in triple-line lateral flow immunoassay, in which two lines (flow control and IAC lines) represent valid negative results and three lines (flow control, IAC, and test line) represent valid positive results. This duplex assay demonstrated a clinical sensitivity of 95%, specificity of 100%, and accuracy of 96% in 30 clinical saliva samples. Significance IACs play a crucial role in ensuring user confidence with respect to the accuracy and reliability of at-home and POC molecular diagnostics. We demonstrated the multiplex capability of SARS-COV-2 and human18S ribosomal RNA RT-LAMP without complicating assay design. This generic platform can be extended in a similar manner to include human18S ribosomal RNA IACs into different clinical sample matrices.
Collapse
Affiliation(s)
- Navaporn Sritong
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Winston Wei Ngo
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Karin F. K. Ejendal
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Jacqueline C. Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
- Department of Public Health, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
4
|
Reynolds J, Loeffler RS, Leigh PJ, Lopez HA, Yoon JY. Recent Uses of Paper Microfluidics in Isothermal Nucleic Acid Amplification Tests. BIOSENSORS 2023; 13:885. [PMID: 37754119 PMCID: PMC10526735 DOI: 10.3390/bios13090885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 09/08/2023] [Accepted: 09/11/2023] [Indexed: 09/28/2023]
Abstract
Isothermal nucleic acid amplification tests have recently gained popularity over polymerase chain reaction (PCR), as they only require a constant temperature and significantly simplify nucleic acid amplification. Recently, numerous attempts have been made to incorporate paper microfluidics into these isothermal amplification tests. Paper microfluidics (including lateral flow strips) have been used to extract nucleic acids, amplify the target gene, and detect amplified products, all toward automating the process. We investigated the literature from 2020 to the present, i.e., since the onset of the COVID-19 pandemic, during which a significant surge in isothermal amplification tests has been observed. Paper microfluidic detection has been used extensively for recombinase polymerase amplification (RPA) and its related methods, along with loop-mediated isothermal amplification (LAMP) and rolling circle amplification (RCA). Detection was conducted primarily with colorimetric and fluorometric methods, although a few publications demonstrated flow distance- and surface-enhanced Raman spectroscopic (SERS)-based detection. A good number of publications could be found that demonstrated both amplification and detection on paper microfluidic platforms. A small number of publications could be found that showed extraction or all three procedures (i.e., fully integrated systems) on paper microfluidic platforms, necessitating the need for future work.
Collapse
Affiliation(s)
- Jocelyn Reynolds
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA; (J.R.); (R.S.L.); (P.J.L.)
| | - Reid S. Loeffler
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA; (J.R.); (R.S.L.); (P.J.L.)
| | - Preston J. Leigh
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA; (J.R.); (R.S.L.); (P.J.L.)
| | - Hannah A. Lopez
- Department of Neuroscience, The University of Arizona, Tucson, AZ 85721, USA;
| | - Jeong-Yeol Yoon
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA; (J.R.); (R.S.L.); (P.J.L.)
| |
Collapse
|
5
|
Song M, Hong S, Lee LP. Multiplexed Ultrasensitive Sample-to-Answer RT-LAMP Chip for the Identification of SARS-CoV-2 and Influenza Viruses. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2207138. [PMID: 36398425 DOI: 10.1002/adma.202207138] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 10/21/2022] [Indexed: 06/16/2023]
Abstract
Prompt on-site diagnosis of SARS-CoV-2 with other respiratory infections will have minimized the global impact of the COVID-19 pandemic through rapid, effective management. However, no such multiplex point-of-care (POC) chip has satisfied a suitable sensitivity of gold-standard nucleic acid amplification tests (NAATs). Here, a rapid multiplexed ultrasensitive sample-to-answer loop-mediated isothermal amplification (MUSAL) chip operated by simple LED-driven photothermal amplification to detect six targets from single-swab sampling is presented. First, the MUSAL chip allows ultrafast on-chip sample preparation with ≈500-fold preconcentration at a rate of 1.2 mL min-1 . Second, the chip enables contamination-free amplification using autonomous target elution into on-chip reagents by photothermal activation. Finally, the chip accomplishes multiplexed on-chip diagnostics of SARS-CoV-2 and influenza viruses with a limit of detection (LoD) of 0.5 copies µL-1 . The rapid, ultrasensitive, cost-effective sample-to-answer chip with a multiplex capability will allow timely management of various pandemics situations that may be faced shortly.
Collapse
Affiliation(s)
- Minsun Song
- Harvard Medical School, Harvard University, Boston, MA, 02115, USA
- Division of Engineering in Medicine and Renal Division, Department of Medicine, Brigham Women's Hospital, Boston, MA, 02115, USA
| | - SoonGweon Hong
- Harvard Medical School, Harvard University, Boston, MA, 02115, USA
- Division of Engineering in Medicine and Renal Division, Department of Medicine, Brigham Women's Hospital, Boston, MA, 02115, USA
| | - Luke P Lee
- Harvard Medical School, Harvard University, Boston, MA, 02115, USA
- Division of Engineering in Medicine and Renal Division, Department of Medicine, Brigham Women's Hospital, Boston, MA, 02115, USA
- Department of Bioengineering, Department of Electrical Engineering and Computer Science, University of California at Berkeley, Berkeley, CA, 94720, USA
- Department of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University (SKKU), Suwon, Gyeonggi-do, 16419, Republic of Korea
| |
Collapse
|