1
|
Li C, Guo Y, Duan K, Wang Z, Wu Z, Jiang X, Yang L, Hu S, Li S, Huang M, Zhong G. Changes in biomarkers of exposure and withdrawal symptom among Chinese adult smokers after completely or partially switching from combustible cigarettes to an electronic nicotine delivery system. Intern Emerg Med 2024; 19:669-679. [PMID: 38316693 DOI: 10.1007/s11739-023-03518-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 12/17/2023] [Indexed: 02/07/2024]
Abstract
This study assessed changes in biomarkers of exposure (BoE) after 5 days of completely or partially switching to an electronic nicotine delivery system (ENDS) use, compared with continued use of combustible cigarettes and smoking abstinence among Chinese adult smokers. A randomized, open-label, parallel-arm study was conducted among Chinese adult smokers who were naive ENDS users. Forty-six subjects were randomized to 4 study groups (n = 11-12 per group): exclusive ENDS use, dual use of ENDS and cigarettes, exclusive cigarettes use, and smoking abstinence. Subjects were confined in clinic for 5 consecutive days and product use was ad libitum. Nicotine and its metabolites (cotinine and 3-hydroxycotinine), and BoEs (AAMA, CEMA, HEMA, HMPMA, 3-HPMA, SPMA, exhaled CO, and exhaled NO) were measured. Withdrawal symptom was measured using MNWS throughout the 5-day period. Six urine BoEs of volatile organic compounds decreased by 55.1-84.1% in the exclusive ENDS use group, which is similar to the smoking abstinence group (67.2-87.4%). The level of decrease was 56.8-70.4% in the dual use group and 10.7-39.0% in the cigarettes group. Urine total nicotine exposure had a non-significant increase in the exclusive ENDS use group, and plasma nicotine and cotinine showed a trend of increasing day by day. After completely or partially switching to ENDS use among Chinese smokers, exposure to selected toxicants were significantly decreased. The results of this study add to the body of evidence that exposure to toxic substance decreased among smokers after complete or partial switch from combustible cigarettes to ENDS use. As part of transition to experienced ENDS use, this study found that smokers of the initial stage who have no prior ENDS experience may increase nicotine intake after switching to ENDS use.
Collapse
Affiliation(s)
- Chenmin Li
- Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, Guangdong, China
| | - Yi Guo
- Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, Guangdong, China
| | - Kun Duan
- RELX Science Center, Shenzhen RELX Tech. Co. Ltd., Shenzhen, 518000, Guangdong, China
| | - Zhi Wang
- Clinical Trial Center of Dongguan KangHua Hospital, Dongguan, 523000, Guangdong, China
| | - Zehong Wu
- RELX Science Center, Shenzhen RELX Tech. Co. Ltd., Shenzhen, 518000, Guangdong, China
| | - Xingtao Jiang
- RELX Science Center, Shenzhen RELX Tech. Co. Ltd., Shenzhen, 518000, Guangdong, China
| | - Ling Yang
- Clinical Trial Center of Dongguan KangHua Hospital, Dongguan, 523000, Guangdong, China
| | - Shiju Hu
- Clinical Trial Center of Dongguan KangHua Hospital, Dongguan, 523000, Guangdong, China
| | - Shoufeng Li
- Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, Guangdong, China
| | - Min Huang
- Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, Guangdong, China
| | - Guoping Zhong
- Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, Guangdong, China.
- Clinical Trial Center of Dongguan KangHua Hospital, Dongguan, 523000, Guangdong, China.
| |
Collapse
|
2
|
Keyser BM, Leverette R, Wertman J, Shutsky T, McRae R, Szeliga K, Makena P, Jordan K. Evaluation of Cytotoxicity and Oxidative Stress of Whole Aerosol from Vuse Alto ENDS Products. TOXICS 2024; 12:129. [PMID: 38393224 PMCID: PMC10892160 DOI: 10.3390/toxics12020129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/18/2024] [Accepted: 01/30/2024] [Indexed: 02/25/2024]
Abstract
Assessment of in vitro cytotoxicity is an important component of tobacco product toxicological evaluations. However, current methods of regulatory testing involve exposing monolayer cell cultures to various preparations of aerosols from cigarettes or other emerging products such as electronic nicotine delivery systems (ENDS), which are not representative of human exposure. In the present study, a whole aerosol (WA) system was used to expose lung epithelial cultures (2D and 3D) to determine the potential of six Vuse Alto ENDS products that varied in nicotine content (1.8%, 2.4%, and 5%) and flavors (Golden Tobacco, Rich Tobacco, Menthol, and Mixed Berry), along with a marketed ENDS and a marked cigarette comparator to induce cytotoxicity and oxidative stress. The WA from the Vuse Alto ENDS products was not cytotoxic in the NRU and MTT assays, nor did it activate the Nrf2 reporter gene, a marker of oxidative stress. In summary, Vuse Alto ENDS products did not induce cytotoxic or oxidative stress responses in the in vitro models. The WA exposures used in the 3D in vitro models described herein may be better suited than 2D models for the determination of cytotoxicity and other in vitro functional endpoints and represent alternative models for regulatory evaluation of tobacco products.
Collapse
Affiliation(s)
- Brian M. Keyser
- RAI Services Company, Winston-Salem, NC 27106, USA; (R.L.); (J.W.); (K.S.); (P.M.); (K.J.)
| | | | | | | | | | | | | | | |
Collapse
|
3
|
Lindson N, Butler AR, McRobbie H, Bullen C, Hajek P, Begh R, Theodoulou A, Notley C, Rigotti NA, Turner T, Livingstone-Banks J, Morris T, Hartmann-Boyce J. Electronic cigarettes for smoking cessation. Cochrane Database Syst Rev 2024; 1:CD010216. [PMID: 38189560 PMCID: PMC10772980 DOI: 10.1002/14651858.cd010216.pub8] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2024]
Abstract
BACKGROUND Electronic cigarettes (ECs) are handheld electronic vaping devices which produce an aerosol by heating an e-liquid. People who smoke, healthcare providers and regulators want to know if ECs can help people quit smoking, and if they are safe to use for this purpose. This is a review update conducted as part of a living systematic review. OBJECTIVES To examine the safety, tolerability and effectiveness of using electronic cigarettes (ECs) to help people who smoke tobacco achieve long-term smoking abstinence, in comparison to non-nicotine EC, other smoking cessation treatments and no treatment. SEARCH METHODS We searched the Cochrane Tobacco Addiction Group's Specialized Register to 1 February 2023, and Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, and PsycINFO to 1 July 2023, and reference-checked and contacted study authors. SELECTION CRITERIA We included trials in which people who smoke were randomized to an EC or control condition. We also included uncontrolled intervention studies in which all participants received an EC intervention as these studies have the potential to provide further information on harms and longer-term use. Studies had to report an eligible outcome. DATA COLLECTION AND ANALYSIS We followed standard Cochrane methods for screening and data extraction. Critical outcomes were abstinence from smoking after at least six months, adverse events (AEs), and serious adverse events (SAEs). We used a fixed-effect Mantel-Haenszel model to calculate risk ratios (RRs) with a 95% confidence interval (CI) for dichotomous outcomes. For continuous outcomes, we calculated mean differences. Where appropriate, we pooled data in pairwise and network meta-analyses (NMA). MAIN RESULTS We included 88 completed studies (10 new to this update), representing 27,235 participants, of which 47 were randomized controlled trials (RCTs). Of the included studies, we rated ten (all but one contributing to our main comparisons) at low risk of bias overall, 58 at high risk overall (including all non-randomized studies), and the remainder at unclear risk. There is high certainty that nicotine EC increases quit rates compared to nicotine replacement therapy (NRT) (RR 1.59, 95% CI 1.29 to 1.93; I2 = 0%; 7 studies, 2544 participants). In absolute terms, this might translate to an additional four quitters per 100 (95% CI 2 to 6 more). There is moderate-certainty evidence (limited by imprecision) that the rate of occurrence of AEs is similar between groups (RR 1.03, 95% CI 0.91 to 1.17; I2 = 0%; 5 studies, 2052 participants). SAEs were rare, and there is insufficient evidence to determine whether rates differ between groups due to very serious imprecision (RR 1.20, 95% CI 0.90 to 1.60; I2 = 32%; 6 studies, 2761 participants; low-certainty evidence). There is moderate-certainty evidence, limited by imprecision, that nicotine EC increases quit rates compared to non-nicotine EC (RR 1.46, 95% CI 1.09 to 1.96; I2 = 4%; 6 studies, 1613 participants). In absolute terms, this might lead to an additional three quitters per 100 (95% CI 1 to 7 more). There is moderate-certainty evidence of no difference in the rate of AEs between these groups (RR 1.01, 95% CI 0.91 to 1.11; I2 = 0%; 5 studies, 1840 participants). There is insufficient evidence to determine whether rates of SAEs differ between groups, due to very serious imprecision (RR 1.00, 95% CI 0.56 to 1.79; I2 = 0%; 9 studies, 1412 participants; low-certainty evidence). Due to issues with risk of bias, there is low-certainty evidence that, compared to behavioural support only/no support, quit rates may be higher for participants randomized to nicotine EC (RR 1.88, 95% CI 1.56 to 2.25; I2 = 0%; 9 studies, 5024 participants). In absolute terms, this represents an additional four quitters per 100 (95% CI 2 to 5 more). There was some evidence that (non-serious) AEs may be more common in people randomized to nicotine EC (RR 1.22, 95% CI 1.12 to 1.32; I2 = 41%, low-certainty evidence; 4 studies, 765 participants) and, again, insufficient evidence to determine whether rates of SAEs differed between groups (RR 0.89, 95% CI 0.59 to 1.34; I2 = 23%; 10 studies, 3263 participants; very low-certainty evidence). Results from the NMA were consistent with those from pairwise meta-analyses for all critical outcomes, and there was no indication of inconsistency within the networks. Data from non-randomized studies were consistent with RCT data. The most commonly reported AEs were throat/mouth irritation, headache, cough, and nausea, which tended to dissipate with continued EC use. Very few studies reported data on other outcomes or comparisons, hence, evidence for these is limited, with CIs often encompassing both clinically significant harm and benefit. AUTHORS' CONCLUSIONS There is high-certainty evidence that ECs with nicotine increase quit rates compared to NRT and moderate-certainty evidence that they increase quit rates compared to ECs without nicotine. Evidence comparing nicotine EC with usual care/no treatment also suggests benefit, but is less certain due to risk of bias inherent in the study design. Confidence intervals were for the most part wide for data on AEs, SAEs and other safety markers, with no difference in AEs between nicotine and non-nicotine ECs nor between nicotine ECs and NRT. Overall incidence of SAEs was low across all study arms. We did not detect evidence of serious harm from nicotine EC, but the longest follow-up was two years and the number of studies was small. The main limitation of the evidence base remains imprecision due to the small number of RCTs, often with low event rates. Further RCTs are underway. To ensure the review continues to provide up-to-date information to decision-makers, this review is a living systematic review. We run searches monthly, with the review updated when relevant new evidence becomes available. Please refer to the Cochrane Database of Systematic Reviews for the review's current status.
Collapse
Affiliation(s)
- Nicola Lindson
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - Ailsa R Butler
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - Hayden McRobbie
- National Drug and Alcohol Research Centre, University of New South Wales, Sydney, Australia
| | - Chris Bullen
- National Institute for Health Innovation, University of Auckland, Auckland, New Zealand
| | - Peter Hajek
- Wolfson Institute of Preventive Medicine, Barts & The London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | - Rachna Begh
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - Annika Theodoulou
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - Caitlin Notley
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Nancy A Rigotti
- Tobacco Research and Treatment Center, Department of Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Tari Turner
- Cochrane Australia, School of Public Health & Preventive Medicine, Monash University, Melbourne, Australia
| | | | - Tom Morris
- Department of Population Health Sciences, University of Leicester, Leicester, UK
| | - Jamie Hartmann-Boyce
- Department of Health Promotion and Policy, University of Massachusetts, Amherst, MA, USA
| |
Collapse
|
4
|
Campbell C, Jin T, Round EK, Nelson PR, Baxter S. Abuse liability of two electronic nicotine delivery systems compared with combustible cigarettes and nicotine gum from an open-label randomized crossover study. Sci Rep 2023; 13:18951. [PMID: 37919490 PMCID: PMC10622442 DOI: 10.1038/s41598-023-45894-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 10/25/2023] [Indexed: 11/04/2023] Open
Abstract
An assessment of the likelihood of use and abuse potential for new tobacco products is an important part of tobacco product regulation in the United States and abroad. This paper reports the results of a randomized, open-label, crossover clinical study that assessed factors related to product adoption and abuse liability (AL), comparing two closed electronic nicotine delivery system (ENDS) products to combustible cigarettes and nicotine gum, high- and low-AL comparator products, respectively. During an 11-day confinement period that included multiple product familiarization sessions, healthy adult smokers participated in AL test sessions to evaluate the abuse liability of each product. During these test sessions, changes in subjective measures; speed and amount of nicotine uptake; and maximum changes in physiological effects before, during, and after use of each assigned product were assessed over 4 h. Positive subjective effects measures scores such as product-liking and overall intent to use again were highest for cigarettes, followed by the Vuse ENDS, with nicotine gum consistently having the lowest scores. The PK results (Cmax and Tmax) of the Vuse ENDS products are between UB cigarettes and nicotine gum, which correlates with the subjective effects. All nicotine uptake measures for the Vuse ENDS products were lower than that of usual brand (UB) cigarettes, including peak nicotine uptake and overall nicotine uptake, and were either similar to or lower than nicotine gum. The time course of nicotine uptake after use of the ENDS was more similar to that of combustible cigarettes than nicotine gum. The results indicate that the AL of each ENDS product is lower than that of UB cigarettes and similar to that of nicotine gum.
Collapse
Affiliation(s)
| | - Tao Jin
- RAI Services Company, 401 N. Main Street, Winston‑Salem, NC, 27101, USA.
| | - Elaine K Round
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| | | | - Sarah Baxter
- British American Tobacco (Investments) Limited, Research and Development, Regents Park Road, Southampton, SO15 8TL, UK
| |
Collapse
|
5
|
Kanobe MN, Nelson PR, Brown BG, Chen P, Makena P, Caraway JW, Prasad GL, Round EK. Changes in Biomarkers of Exposure and Potential Harm in Smokers Switched to Vuse Vibe or Vuse Ciro Electronic Nicotine Delivery Systems. TOXICS 2023; 11:564. [PMID: 37505530 PMCID: PMC10384956 DOI: 10.3390/toxics11070564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 06/05/2023] [Accepted: 06/27/2023] [Indexed: 07/29/2023]
Abstract
Electronic nicotine delivery systems (ENDS) have the potential to provide nicotine to tobacco consumers while reducing exposure to combustion-related toxicants. Here, we report changes in biomarkers of exposure (BoE) and biomarkers of potential harm (BoPH) in smokers who completely switched to Vuse Vibe and Vuse Ciro ENDS products, or to smoking abstinence in a randomized, controlled clinical study. Thirteen BoE (12 urinary and one blood) that indicate exposure to harmful and potentially harmful toxicants (HPHCs) were evaluated at baseline on day 5. Urinary BoPH linked to oxidative stress, platelet activation, and inflammation were also assessed at baseline, and on day 5 and day 7. Nicotine exposure was lower in Vuse Vibe and Vuse Ciro groups compared to baseline values. Urinary non-nicotine BoE decreased significantly (52.3-96.7%) in the Vuse ENDS groups, and the reductions were similar in magnitude to those observed in the abstinence group. Blood carboxyhemoglobin decreased 52.8-55.0% in all study groups. Decreases (10-50%) in BoPH were observed in all study groups. Thus, smokers who switch exclusively to Vuse Vibe or Vuse Ciro products or completely abstain from smoking are exposed to substantially lower levels of HPHCs, and experience improvements in BoPH of oxidative stress and inflammation pathways.
Collapse
Affiliation(s)
- Milly N Kanobe
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - Paul R Nelson
- Former Employees of RAI Services Company, 105 Bowes Road, Winston Salem, NC 27106, USA
| | - Buddy G Brown
- Former Employees of RAI Services Company, 5714 Wonderous Lane, Durham, NC 27712, USA
| | - Peter Chen
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - Patrudu Makena
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - John W Caraway
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - Gaddamanugu L Prasad
- Former Employees of RAI Services Company, 490 Friendship Place Ct, Lewisville, NC 27023, USA
- Prasad Scientific Consulting LLC, 490 Friendship Place Ct, Lewisville, NC 27023, USA
| | - Elaine K Round
- BAT (Investments) Limited, Globe House, 1 Water Street, London WC2R 3LA, UK
| |
Collapse
|
6
|
Keyser BM, Hong KS, DeLuca P, Jin T, Jones BA, Nelson P, Schmidt E, Round EK. Part two: an unblinded, parallel, randomized study to assess nicotine pharmacokinetics of four Vuse Solo ENDS flavors in smokers. Sci Rep 2023; 13:8894. [PMID: 37264061 DOI: 10.1038/s41598-023-35439-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 05/18/2023] [Indexed: 06/03/2023] Open
Abstract
We report the findings from a randomized, parallel study designed to evaluate nicotine pharmacokinetics (PK) following 10 min of ad libitum use of electronic nicotine delivery system (ENDS) in four flavor variants. Subjects were randomized an investigational product (IP) and blood samples were collected for PK assessments during a test session. Primary endpoints were baseline-adjusted values of maximum plasma nicotine concentration (Cmax) and area under the nicotine concentration-vs-time curve up to 60 min (AUCnic0-60). Baseline-adjusted mean Cmax ranged from 6.53 to 8.21 ng/mL, and mean AUCnic0-60 ranged from 206.87 to 263.52 ng min/mL for all ENDS IPs. Results of geometric mean Cmax and AUCnic0-60 values were within 95% confidence intervals (CI) among the ENDS IP flavor variants tested.
Collapse
Affiliation(s)
- Brian M Keyser
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Kyung Soo Hong
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Patricia DeLuca
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA.
| | - Tao Jin
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Bobbette A Jones
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Paul Nelson
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Eckhardt Schmidt
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Elaine K Round
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| |
Collapse
|
7
|
Makena P, Scott E, Chen P, Liu HP, Jones BA, Prasad GL. Biomarkers of Exposure and Potential Harm in Two Weeks of Smoking Abstinence: Changes in Biomarkers of Platelet Function, Oxidative Stress, and Inflammation. Int J Mol Sci 2023; 24:ijms24076286. [PMID: 37047257 PMCID: PMC10093936 DOI: 10.3390/ijms24076286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 03/19/2023] [Accepted: 03/21/2023] [Indexed: 03/29/2023] Open
Abstract
: Chronic cigarette smoking is a major risk factor for many serious diseases. While complete cessation of smoking is the best option to reduce harm from smoking, adverse impacts of smoking on health could persist for several years after cessation. Therefore, Biomarkers of Potential Harm (BoPH) are useful in interim evaluations of the beneficial effects of smoking cessation or switching to potentially lower-risk tobacco products. A 14-day smoking abstinence study was conducted under clinical confinement conditions and enrolled 70 subjects into younger (24–34 years, n = 33) and older (35–60 years, n = 37) age cohorts. Biomarkers of Exposure (BoE), which indicate exposure to nicotine and other toxicants, were measured at baseline, 7 and 14 days. Several BoPH including previously identified eicosanoids (leukotriene 4 (LTE4) and 2,3-dinor thromboxane 2 (2,3-d-TXB2) and others were evaluated. Significant declines in BoE, LTE4, 2,3-d-TXB2, neutrophils, WBC and select RBC, and arterial blood gas parameters were observed in both age cohorts at Days 7 and 14 compared to baseline, while other BoPH (e.g., FeNO) showed age-related effects. Rapid and reproducible reductions in LTE4, 2,3-d-TXB2 WBC, and neutrophil counts were consistently detected following smoking abstinence, indicating the value of these markers as useful BoPH.
Collapse
Affiliation(s)
- Patrudu Makena
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - Eric Scott
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - Peter Chen
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - Hsiao-Pin Liu
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - Bobbette A Jones
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
| | - Gaddamanugu L Prasad
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA
- Prasad Scientific Consulting LLC, Lewisville, NC 27023, USA
| |
Collapse
|
8
|
Campbell C, Jin T, Round EK, Schmidt E, Nelson P, Baxter S. Part one: abuse liability of Vuse Solo (G2) electronic nicotine delivery system relative to combustible cigarettes and nicotine gum. Sci Rep 2022; 12:22080. [PMID: 36543869 PMCID: PMC9772348 DOI: 10.1038/s41598-022-26417-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 12/14/2022] [Indexed: 12/24/2022] Open
Abstract
Abuse liability (AL) of electronic nicotine delivery systems (ENDS) is relevant as the category increases in popularity as a potentially less-harmful alternative to cigarette smoking. AL assessments are important to the FDA in determining if a new product is appropriate for the protection of public health. This paper reports the results for Vuse Solo (G2 cartridge design) compared to high and low AL-comparators evaluated in an open-label, randomized crossover confinement AL study. The confinement design was adapted from previous ambulatory studies of Vuse Solo (G1 cartridge design) and included product familiarization sessions before each four-hour test session in which subjective measures, nicotine pharmacokinetics (PK), and physiological endpoints were assessed following a single 10-min ad libitum product use session. Product liking, intent to use again, suppression of urge to smoke, and nicotine PK were lower after use of Vuse Solo compared to cigarettes and higher after use of Vuse Solo compared to nicotine gum. No significant differences in blood pressure or heart rate were observed between the products pre- to post-product use. These data reinforce previous research and provide the scientific evidence to support regulatory decisions demonstrating that Vuse Solo has an AL profile lower than that of combustible cigarettes but higher than that of nicotine gum and, therefore, may be a suitable replacement for cigarette smoking for some adult smokers.
Collapse
Affiliation(s)
- Chris Campbell
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA.
| | - Tao Jin
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Elaine K Round
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Eckhardt Schmidt
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| | - Paul Nelson
- Retired Employee of RAI Services Company, Winston-Salem, NC, 27101, USA
| | - Sarah Baxter
- RAI Services Company, 401 N. Main Street, Winston-Salem, NC, 27101, USA
| |
Collapse
|