1
|
Gil-Castillo J, Herrera-Valenzuela D, Torricelli D, Gil-Agudo Á, Opisso E, Vidal J, Font-Llagunes JM, Del-Ama AJ, Moreno JC. A new modular neuroprosthesis suitable for hybrid FES-robot applications and tailored assistance. J Neuroeng Rehabil 2024; 21:153. [PMID: 39232831 PMCID: PMC11373245 DOI: 10.1186/s12984-024-01450-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 05/30/2024] [Indexed: 09/06/2024] Open
Abstract
BACKGROUND To overcome the application limitations of functional electrical stimulation (FES), such as fatigue or nonlinear muscle response, the combination of neuroprosthetic systems with robotic devices has been evaluated, resulting in hybrid systems that have promising potential. However, current technology shows a lack of flexibility to adapt to the needs of any application, context or individual. The main objective of this study is the development of a new modular neuroprosthetic system suitable for hybrid FES-robot applications to meet these needs. METHODS In this study, we conducted an analysis of the requirements for developing hybrid FES-robot systems and reviewed existing literature on similar systems. Building upon these insights, we developed a novel modular neuroprosthetic system tailored for hybrid applications. The system was specifically adapted for gait assistance, and a technological personalization process based on clinical criteria was devised. This process was used to generate different system configurations adjusted to four individuals with spinal cord injury or stroke. The effect of each system configuration on gait kinematic metrics was analyzed by using repeated measures ANOVA or Friedman's test. RESULTS A modular NP system has been developed that is distinguished by its flexibility, scalability and personalization capabilities. With excellent connection characteristics, it can be effectively integrated with robotic devices. Its 3D design facilitates fitting both as a stand-alone system and in combination with other robotic devices. In addition, it meets rigorous requirements for safe use by incorporating appropriate safety protocols, and features appropriate battery autonomy, weight and dimensions. Different technological configurations adapted to the needs of each patient were obtained, which demonstrated an impact on the kinematic gait pattern comparable to that of other devices reported in the literature. CONCLUSIONS The system met the identified technical requirements, showcasing advancements compared to systems reported in the literature. In addition, it demonstrated its versatility and capacity to be combined with robotic devices forming hybrids, adapting well to the gait application. Moreover, the personalization procedure proved to be useful in obtaining various system configurations tailored to the diverse needs of individuals.
Collapse
Affiliation(s)
- Javier Gil-Castillo
- BioRobotics Group, Center for Automation and Robotics, CSIC, Madrid, Spain
- ETSI Telecomunicación, Universidad Politécnica de Madrid, Madrid, España
| | - Diana Herrera-Valenzuela
- International Doctoral School, Rey Juan Carlos University, Madrid, Spain
- Biomechanics and Technical Aids Unit, National Hospital for Paraplegics, Toledo, Spain
| | - Diego Torricelli
- BioRobotics Group, Center for Automation and Robotics, CSIC, Madrid, Spain
| | - Ángel Gil-Agudo
- Biomechanics and Technical Aids Unit, National Hospital for Paraplegics, Toledo, Spain
- Unit of Neurorehabilitation, Biomechanics and Sensorimotor Function (HNP-SESCAM), Associated Unit of R&D&I to the CSIC, Madrid, Spain
| | - Eloy Opisso
- Institut Guttmann, Institut Universitari de Neurorehabilitació adscrit a la UAB, Badalona, Barcelona, 08916, Spain
| | - Joan Vidal
- Institut Guttmann, Institut Universitari de Neurorehabilitació adscrit a la UAB, Badalona, Barcelona, 08916, Spain
| | - Josep M Font-Llagunes
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Centre for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, Barcelona, 08028, Spain
- Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, Esplugues de Llobregat, 08950, Spain
| | - Antonio J Del-Ama
- Bioengineering Systems and Technologies Research Group, Department of Applied Mathematics, Materials Science and Engineering and Electronic Technology, Rey Juan Carlos University, C/ Tulipan S/N, Móstoles, 28933, Spain
| | - Juan C Moreno
- BioRobotics Group, Center for Automation and Robotics, CSIC, Madrid, Spain.
- ETSI Telecomunicación, Universidad Politécnica de Madrid, Madrid, España.
| |
Collapse
|
2
|
Boljanić T, Baljić M, Kostić M, Barralon P, Došen S, Štrbac M. Psychometric evaluation of high-resolution electrotactile interface for conveying 3D spatial information. Sci Rep 2024; 14:19969. [PMID: 39198659 PMCID: PMC11358320 DOI: 10.1038/s41598-024-70990-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 08/22/2024] [Indexed: 09/01/2024] Open
Abstract
This study presents a detailed psychometric evaluation of a novel high-resolution electrotactile interface, which is developed to provide users with 3D spatial information and facilitate enhanced interaction with a Supernumerary Robotic Limb (SRL). The research introduces a novel electrotactile system that employs a multi-pad electrode configuration on the thigh, aimed at delivering intuitive feedback to users about the position of the SRL in a three-dimensional space. The interface's effectiveness was assessed through a series of psychometric tests, including static spatial discrimination, target-reaching with spatial feedback, frequency discrimination, and combined spatial/frequency modulation. The key findings demonstrate that participants could differentiate between 30 electrode pads with an average success rate of 62.7% when they were activated statically, while in the dynamic target-reaching task, the success rate increased to 88.1%. Frequency discrimination tests further revealed that four frequency levels could be distinguished with 86.0% success rate in single-pad feedback while the performance decreased to 74.3% in multi-pad distributed feedback. Finaly, in the closed-loop test with mixed spatial and frequency modulation, participants achieved an overall success rate of 78.8% in target reaching across 10 × 4 discrete 2D space. These results highlight the interface's capability to transmit high-resolution spatial information through electrotactile feedback, offering a foundation for future applications in tactile-based navigation and control systems.
Collapse
Affiliation(s)
- Tanja Boljanić
- Tecnalia Serbia doo, 11000, Belgrade, Serbia.
- School of Electrical Engineering, University of Belgrade, 11000, Belgrade, Serbia.
| | | | | | - Pierre Barralon
- TECNALIA Basque Research and Technology Alliance (BRTA), 20009, Donostia-San Sebastián, Spain
| | - Strahinja Došen
- Department of Health Science and Technology, Aalborg University, 9260, Gistrup, Denmark
| | | |
Collapse
|
3
|
Mereu F, Cordella F, Paolini R, Scarpelli A, Demofonti A, Zollo L, Gruppioni E. A Sensory Feedback Neural Stimulator Prototype for Both Implantable and Wearable Applications. MICROMACHINES 2024; 15:480. [PMID: 38675291 PMCID: PMC11051761 DOI: 10.3390/mi15040480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 03/23/2024] [Accepted: 03/29/2024] [Indexed: 04/28/2024]
Abstract
The restoration of sensory feedback is one of the current challenges in the field of prosthetics. This work, following the analysis of the various types of sensory feedback, aims to present a prototype device that could be used both for implantable applications to perform PNS and for wearable applications, performing TENS, to restore sensory feedback. The two systems are composed of three electronic boards that are presented in detail, as well as the bench tests carried out. To the authors' best knowledge, this work presents the first device that can be used in a dual scenario for restoring sensory feedback. Both the implantable and wearable versions respected the expected values regarding the stimulation parameters. In its implantable version, the proposed system allows simultaneous and independent stimulation of 30 channels. Furthermore, the capacity of the wearable version to elicit somatic sensations was evaluated on healthy participants demonstrating performance comparable with commercial solutions.
Collapse
Affiliation(s)
- Federico Mereu
- Centro Protesi Inail, Vigorso di Budrio, 40054 Bologna, Italy;
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (R.P.); (A.S.); (A.D.); (L.Z.)
| | - Francesca Cordella
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (R.P.); (A.S.); (A.D.); (L.Z.)
| | - Roberto Paolini
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (R.P.); (A.S.); (A.D.); (L.Z.)
| | - Alessia Scarpelli
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (R.P.); (A.S.); (A.D.); (L.Z.)
| | - Andrea Demofonti
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (R.P.); (A.S.); (A.D.); (L.Z.)
| | - Loredana Zollo
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (R.P.); (A.S.); (A.D.); (L.Z.)
| | | |
Collapse
|
4
|
Li R, Zhang P, Lu J, Zhuang J, Wang M, Fang H, Zhang X, Gao Y, Yang Z, Chin KL. Case report: Ultrasound-guided median nerve electrical stimulation on functional recovery of hemiplegic upper limb after stroke. Front Neurol 2023; 14:1244192. [PMID: 38046582 PMCID: PMC10691377 DOI: 10.3389/fneur.2023.1244192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Accepted: 11/03/2023] [Indexed: 12/05/2023] Open
Abstract
Background Functional restoration of hemiplegic upper limbs is a difficult area in the field of neurological rehabilitation. Electrical stimulation is one of the treatments that has shown promising advancements and functional improvements. Most of the electrical stimulations used in clinical practice are surface stimulations. In this case, we aimed to investigate the feasibility of a minimally invasive, ultrasound-guided median nerve electrical stimulation (UG-MNES) in improving the upper limb motor function and activity of a patient with right-sided hemiparesis. Case presentation A 65-year-old male recovering from a left massive intracerebral hemorrhage after open debridement hematoma removal had impaired right limb movement, right hemianesthesia, motor aphasia, dysphagia, and complete dependence on his daily living ability. After receiving 3 months of conventional rehabilitation therapy, his cognitive, speech, and swallowing significantly improved but the Brunnstrom Motor Staging (BMS) of his right upper limb and hand was at stage I-I. UG-MNES was applied on the right upper limb for four sessions, once per week, together with conventional rehabilitation. Immediate improvement in the upper limb function was observed after the first treatment. To determine the effect of UG-MNES on long-term functional recovery, assessments were conducted a week after the second and fourth intervention sessions, and motor function recovery was observed after 4-week of rehabilitation. After completing the full rehabilitation course, his BMS was at stage V-IV, the completion time of Jebsen Hand Function Test (JHFT) was shortened, and the scores of Fugl-Meyer Assessment for upper extremity (FMA-UE) and Modified Barthel Index (MBI) were increased. Overall, the motor function of the hemiplegic upper limb had significantly improved, and the right hand was the utility hand. Electromyography (EMG) and nerve conduction velocity (NCV) tests were normal before and after treatment. Conclusion The minimally invasive, UG-MNES could be a new alternative treatment in stroke rehabilitation for functional recovery of the upper limbs.
Collapse
Affiliation(s)
- Rui Li
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
- Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, Universiti Malaysia Sabah, Kota Kinabalu, Sabah, Malaysia
| | - Ping Zhang
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
| | - Jingyi Lu
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
| | - Jianlin Zhuang
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
| | - Meiqi Wang
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
| | - Hongmei Fang
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
| | - Xiaowei Zhang
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
| | - Ying Gao
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
| | - Zhufen Yang
- Department of Rehabilitation Medicine, The Second People’s Hospital of Kunming, Rehabilitation Hospital Affiliated to Kunming University, Kunming, China
| | - Kai Ling Chin
- Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, Universiti Malaysia Sabah, Kota Kinabalu, Sabah, Malaysia
- Borneo Medical and Health Research Centre (BMHRC), Faculty of Medicine and Health Sciences, Universiti Malaysia Sabah, Kota Kinabalu, Sabah, Malaysia
| |
Collapse
|