1
|
Mosavi SS, Rabizadeh S, Yadegar A, Seifouri S, Mohammadi F, Qahremani R, Salehi SS, Rajab A, Esteghamati A, Nakhjavani M. Therapeutic effects of resveratrol and Omega-3 in mice atherosclerosis: focus on histopathological changes. BMC Complement Med Ther 2023; 23:81. [PMID: 36932392 PMCID: PMC10024363 DOI: 10.1186/s12906-023-03899-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 02/27/2023] [Indexed: 03/19/2023] Open
Abstract
BACKGROUND Resveratrol and omega-3 have been shown to prevent atherosclerosis. However, histopathological changes and their comparison have not been studied well. This study investigated the therapeutic effects of resveratrol and omega-3 in experimental atherosclerosis of mice. METHODS We divided sixty 6-week-old male C57BL/6 mice into six groups and followed for 10 weeks: (1) standard diet, (2) atherogenic diet, (3) atherogenic diet along with resveratrol from the start of the sixth week, (4) atherogenic diet along with omega-3 from the start of the sixth week, (5) standard diet along with resveratrol from the start of the sixth week, (6) standard diet along with omega-3 from the start of the sixth week. RESULTS The mice fed on an atherogenic diet had a larger fat area and a thicker aortic wall thickness than mice fed on a standard diet. The use of omega-3 and resveratrol in the mice with an atherogenic diet resulted in a significantly reduced fat area (p-value = 0.003), and resveratrol had a significantly higher effect. Omega-3 or resveratrol induced a significant reduction in aortic wall thickness in mice on an atherogenic diet, and there was no significant difference between them. Among the mice with a standard diet, this study did not observe any significant changes in the fat area or the aortic wall thickness with the consumption of omega-3 or resveratrol. CONCLUSIONS Resveratrol and omega-3 had a regressive and therapeutic role in atherosclerosis, with a more significant effect in favor of resveratrol.
Collapse
Affiliation(s)
- Shamsi Sadat Mosavi
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Soghra Rabizadeh
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Amirhossein Yadegar
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Sara Seifouri
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Fatemeh Mohammadi
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Reihane Qahremani
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Salome Sadat Salehi
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Armin Rajab
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Alireza Esteghamati
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| | - Manouchehr Nakhjavani
- grid.414574.70000 0004 0369 3463Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Imam Khomeini Hospital Complex, Tohid Squre, P.O Box: 13145-784, Tehran, Iran
| |
Collapse
|
2
|
Birnbacher L, Braig EM, Pfeiffer D, Pfeiffer F, Herzen J. Quantitative X-ray phase contrast computed tomography with grating interferometry : Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography. Eur J Nucl Med Mol Imaging 2021; 48:4171-4188. [PMID: 33846846 PMCID: PMC8566444 DOI: 10.1007/s00259-021-05259-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 02/11/2021] [Indexed: 11/25/2022]
Abstract
The ability of biomedical imaging data to be of quantitative nature is getting increasingly important with the ongoing developments in data science. In contrast to conventional attenuation-based X-ray imaging, grating-based phase contrast computed tomography (GBPC-CT) is a phase contrast micro-CT imaging technique that can provide high soft tissue contrast at high spatial resolution. While there is a variety of different phase contrast imaging techniques, GBPC-CT can be applied with laboratory X-ray sources and enables quantitative determination of electron density and effective atomic number. In this review article, we present quantitative GBPC-CT with the focus on biomedical applications.
Collapse
Affiliation(s)
- Lorenz Birnbacher
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Eva-Maria Braig
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Franz Pfeiffer
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Julia Herzen
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany.
| |
Collapse
|
3
|
Zhang L, Li L, Feng G, Fan T, Jiang H, Wang Z. Advances in CT Techniques in Vascular Calcification. Front Cardiovasc Med 2021; 8:716822. [PMID: 34660718 PMCID: PMC8511450 DOI: 10.3389/fcvm.2021.716822] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Accepted: 08/30/2021] [Indexed: 12/17/2022] Open
Abstract
Vascular calcification, a common pathological phenomenon in atherosclerosis, diabetes, hypertension, and other diseases, increases the incidence and mortality of cardiovascular diseases. Therefore, the prevention and detection of vascular calcification play an important role. At present, various techniques have been applied to the analysis of vascular calcification, but clinical examination mainly depends on non-invasive and invasive imaging methods to detect and quantify. Computed tomography (CT), as a commonly used clinical examination method, can analyze vascular calcification. In recent years, with the development of technology, in addition to traditional CT, some emerging types of CT, such as dual-energy CT and micro CT, have emerged for vascular imaging and providing anatomical information for calcification. This review focuses on the latest application of various CT techniques in vascular calcification.
Collapse
Affiliation(s)
- Lijie Zhang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Lihua Li
- Department of Pathology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Guoquan Feng
- Department of Radiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Tingpan Fan
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Han Jiang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Zhongqun Wang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| |
Collapse
|
4
|
A versatile technique for high-resolution three-dimensional imaging of human arterial segments using microcomputed tomography. JVS Vasc Sci 2021; 2:13-19. [PMID: 34617054 PMCID: PMC8489243 DOI: 10.1016/j.jvssci.2020.08.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 08/04/2020] [Indexed: 11/22/2022] Open
Abstract
Background Quantitative methods for evaluating microstructure of arterial specimens typically rely on histologic techniques that involve random sampling, which cannot account for the unique spatial distribution of features in three dimensions. Methods To overcome this limitation, we demonstrate a nondestructive method for three-dimensional imaging of intact human blood vessels using microcomputed tomography (microCT). Human artery segments were dehydrated and stained in an iodine solution then imaged with a standard laboratory microCT scanner. Image visualization and segmentation was performed using commercially available and open source software. Results Staining of cadaveric vessels with iodine enabled clear visualization of the arterial wall with microCT, preserved tissue morphology, and generated high-resolution images with a voxel size of 5.4 μm. Various components of the arterial wall were segmented using a combination of manual and automatic thresholding algorithms. Conclusions Our approach allows for spatial mapping of human artery tissue samples that can guide targeted histologic analysis of smaller tissue segments, provide geometric data to inform finite element models, quantify degree of atherosclerosis, and help to evaluate the foreign body response to intravascular medical implants. (JVS-Vascular Science 2020;2:13-19.). Clinical Relevance In this article, we describe a powerful technique for whole artery analysis of pathologic human tissue specimens that provides high-resolution spatial detail regarding composition of the blood vessel wall. The protocol described here is a valuable adjunct that can be used as a research tool to inform finite element modeling of arteries, quantify pathologic response (ie, neointimal hyperplasia and vascular calcification), and evaluate the tissue/device interface of implanted medical devices.
Collapse
|
5
|
Shedding 3D light on endothelial barrier function in arteries. Atherosclerosis 2020; 310:91-92. [DOI: 10.1016/j.atherosclerosis.2020.07.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 07/31/2020] [Indexed: 11/19/2022]
|
6
|
Becher T, Riascos-Bernal DF, Kramer DJ, Almonte VM, Chi J, Tong T, Oliveira-Paula GH, Koleilat I, Chen W, Cohen P, Sibinga NES. Three-Dimensional Imaging Provides Detailed Atherosclerotic Plaque Morphology and Reveals Angiogenesis After Carotid Artery Ligation. Circ Res 2020; 126:619-632. [PMID: 31914850 DOI: 10.1161/circresaha.119.315804] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
RATIONALE Remodeling of the vessel wall and the formation of vascular networks are dynamic processes that occur during mammalian embryonic development and in adulthood. Plaque development and excessive neointima formation are hallmarks of atherosclerosis and vascular injury. As our understanding of these complex processes evolves, there is a need to develop new imaging techniques to study underlying mechanisms. OBJECTIVE We used tissue clearing and light-sheet microscopy for 3-dimensional (3D) profiling of the vascular response to carotid artery ligation and induction of atherosclerosis in mouse models. METHODS AND RESULTS Adipo-Clear and immunolabeling in combination with light-sheet microscopy were applied to image carotid arteries and brachiocephalic arteries, allowing for 3D reconstruction of vessel architecture. Entire 3D neointima formations with different geometries were observed within the carotid artery and scored by volumetric analysis. Additionally, we identified a CD31-positive adventitial plexus after ligation of the carotid artery that evolved and matured over time. We also used this method to characterize plaque extent and composition in the brachiocephalic arteries of ApoE-deficient mice on high-fat diet. The plaques exhibited inter-animal differences in terms of plaque volume, geometry, and ratio of acellular core to plaque volume. A 3D reconstruction of the endothelium overlying the plaque was also generated. CONCLUSIONS We present a novel approach to characterize vascular remodeling in adult mice using Adipo-Clear in combination with light-sheet microscopy. Our method reconstructs 3D neointima formation after arterial injury and allows for volumetric analysis of remodeling, in addition to revealing angiogenesis and maturation of a plexus surrounding the carotid artery. This method generates complete 3D reconstructions of atherosclerotic plaques and uncovers their volume, geometry, acellular component, surface, and spatial position within the brachiocephalic arteries. Our approach may be used in a number of mouse models of cardiovascular disease to assess vessel geometry and volume. Visual Overview: An online visual overview is available for this article.
Collapse
Affiliation(s)
- Tobias Becher
- From the Laboratory of Molecular Metabolism (T.B., D.J.K., J.C., P.C.), The Rockefeller University, NY.,DZHK (German Centre for Cardiovascular Research), Partner Site Heidelberg/Mannheim, Germany (T.B.).,First Department of Medicine (Division of Cardiology), University Medical Center Mannheim, Germany (T.B.)
| | - Dario F Riascos-Bernal
- (Cardiology Division) Department of Medicine, Department of Developmental and Molecular Biology, Wilf Family Cardiovascular Research Institute (D.F.R.-B., V.M.A., G.H.O.-P., N.E.S.S.), Albert Einstein College of Medicine, Bronx, NY
| | - Daniel J Kramer
- From the Laboratory of Molecular Metabolism (T.B., D.J.K., J.C., P.C.), The Rockefeller University, NY
| | - Vanessa M Almonte
- (Cardiology Division) Department of Medicine, Department of Developmental and Molecular Biology, Wilf Family Cardiovascular Research Institute (D.F.R.-B., V.M.A., G.H.O.-P., N.E.S.S.), Albert Einstein College of Medicine, Bronx, NY
| | - Jingy Chi
- From the Laboratory of Molecular Metabolism (T.B., D.J.K., J.C., P.C.), The Rockefeller University, NY
| | - Tao Tong
- Bio-Imaging Resource Center (T.T.), The Rockefeller University, NY
| | - Gustavo H Oliveira-Paula
- (Cardiology Division) Department of Medicine, Department of Developmental and Molecular Biology, Wilf Family Cardiovascular Research Institute (D.F.R.-B., V.M.A., G.H.O.-P., N.E.S.S.), Albert Einstein College of Medicine, Bronx, NY
| | - Issam Koleilat
- Department of Cardiothoracic and Vascular Surgery (Division of Vascular Surgery), Montefiore Medical Center, Bronx, NY (I.K.)
| | - Wei Chen
- Department of Medicine (Nephrology Division) (W.C.), Albert Einstein College of Medicine, Bronx, NY.,Department of Medicine, University of Rochester School of Medicine and Dentistry, NY (W.C.)
| | - Paul Cohen
- From the Laboratory of Molecular Metabolism (T.B., D.J.K., J.C., P.C.), The Rockefeller University, NY
| | - Nicholas E S Sibinga
- (Cardiology Division) Department of Medicine, Department of Developmental and Molecular Biology, Wilf Family Cardiovascular Research Institute (D.F.R.-B., V.M.A., G.H.O.-P., N.E.S.S.), Albert Einstein College of Medicine, Bronx, NY
| |
Collapse
|
7
|
Norvik C, Westöö CK, Peruzzi N, Lovric G, van der Have O, Mokso R, Jeremiasen I, Brunnström H, Galambos C, Bech M, Tran-Lundmark K. Synchrotron-based phase-contrast micro-CT as a tool for understanding pulmonary vascular pathobiology and the 3-D microanatomy of alveolar capillary dysplasia. Am J Physiol Lung Cell Mol Physiol 2019; 318:L65-L75. [PMID: 31596108 DOI: 10.1152/ajplung.00103.2019] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
This study aimed to explore the value of synchrotron-based phase-contrast microcomputed tomography (micro-CT) in pulmonary vascular pathobiology. The microanatomy of the lung is complex with intricate branching patterns. Tissue sections are therefore difficult to interpret. Recruited intrapulmonary bronchopulmonary anastomoses (IBAs) have been described in several forms of pulmonary hypertension, including alveolar capillary dysplasia with misaligned pulmonary veins (ACD/MPV). Here, we examine paraffin-embedded tissue using this nondestructive method for high-resolution three-dimensional imaging. Blocks of healthy and ACD/MPV lung tissue were used. Pulmonary and bronchial arteries in the ACD/MPV block had been preinjected with dye. One section per block was stained, and areas of interest were marked to allow precise beam-alignment during image acquisition at the X02DA TOMCAT beamline (Swiss Light Source). A ×4 magnifying objective coupled to a 20-µm thick scintillating material and a sCMOS detector yielded the best trade-off between spatial resolution and field-of-view. A phase retrieval algorithm was applied and virtual tomographic slices and video clips of the imaged volumes were produced. Dye injections generated a distinct attenuation difference between vessels and surrounding tissue, facilitating segmentation and three-dimensional rendering. Histology and immunohistochemistry post-imaging offered complementary information. IBAs were confirmed in ACD/MPV, and the MPVs were positioned like bronchial veins/venules. We demonstrate the advantages of using synchrotron-based phase-contrast micro-CT for three-dimensional characterization of pulmonary microvascular anatomy in paraffin-embedded tissue. Vascular dye injections add additional value. We confirm intrapulmonary shunting in ACD/MPV and provide support for the hypothesis that MPVs are dilated bronchial veins/venules.
Collapse
Affiliation(s)
- Christian Norvik
- Department of Experimental Medical Science, Lund University, Lund, Sweden
| | | | - Niccolò Peruzzi
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Goran Lovric
- Centre d'Imagerie BioMédicale, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.,Swiss Light Source, Paul Scherrer Institute, Villigen, Switzerland
| | - Oscar van der Have
- Department of Experimental Medical Science, Lund University, Lund, Sweden
| | | | - Ida Jeremiasen
- Department of Experimental Medical Science, Lund University, Lund, Sweden
| | - Hans Brunnström
- Division of Oncology and Pathology, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - Csaba Galambos
- Children's Hospital Colorado, Department of Pathology and Laboratory Medicine, Aurora, Colorado
| | - Martin Bech
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | | |
Collapse
|
8
|
Vigne J, Thackeray J, Essers J, Makowski M, Varasteh Z, Curaj A, Karlas A, Canet-Soulas E, Mulder W, Kiessling F, Schäfers M, Botnar R, Wildgruber M, Hyafil F. Current and Emerging Preclinical Approaches for Imaging-Based Characterization of Atherosclerosis. Mol Imaging Biol 2019; 20:869-887. [PMID: 30250990 DOI: 10.1007/s11307-018-1264-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Atherosclerotic plaques can remain quiescent for years, but become life threatening upon rupture or disruption, initiating clot formation in the vessel lumen and causing acute myocardial infarction and ischemic stroke. Whether and how a plaque ruptures is determined by its macroscopic structure and microscopic composition. Rupture-prone plaques usually consist of a thin fibrous cap with few smooth muscle cells, a large lipid core, a dense infiltrate of inflammatory cells, and neovessels. Such lesions, termed high-risk plaques, can remain asymptomatic until the thrombotic event. Various imaging technologies currently allow visualization of morphological and biological characteristics of high-risk atherosclerotic plaques. Conventional protocols are often complex and lack specificity for high-risk plaque. Conversely, new imaging approaches are emerging which may overcome these limitations. Validation of these novel imaging techniques in preclinical models of atherosclerosis is essential for effective translational to clinical practice. Imaging the vessel wall, as well as its biological milieu in small animal models, is challenging because the vessel wall is a small structure that undergoes continuous movements imposed by the cardiac cycle as it is adjacent to circulating blood. The focus of this paper is to provide a state-of-the-art review on techniques currently available for preclinical imaging of atherosclerosis in small animal models and to discuss the advantages and limitations of each approach.
Collapse
Affiliation(s)
- Jonathan Vigne
- Department of Nuclear Medicine, Bichat University Hospital, AP-HP; INSERM, U-1148, DHU FIRE, University Diderot, Paris, France
| | - James Thackeray
- Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| | - Jeroen Essers
- Departments of Vascular Surgery, Molecular Genetics, Radiation Oncology, Erasmus MC, Rotterdam, The Netherlands
| | - Marcus Makowski
- Department of Radiology, Charité-University Medicine Berlin, Berlin, Germany
| | - Zoreh Varasteh
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Adelina Curaj
- Institute for Molecular Cardiovascular Research (IMCAR), Institute for Experimental Molecular Imaging (ExMI), University Hospital Aachen, RWTH, Aachen, Germany
| | - Angelos Karlas
- Institute for Biological and Medical Imaging, Helmholtz Zentrum München, Oberschleissheim, Germany
| | - Emmanuel Canet-Soulas
- Laboratoire CarMeN, INSERM U-1060, Lyon/Hospices Civils Lyon, IHU OPERA Cardioprotection, Université de Lyon, Bron, France
| | - Willem Mulder
- Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, Mount Sinai, New York, USA
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging (ExMI), University Hospital Aachen, RWTH, Aachen, Germany
| | - Michael Schäfers
- Department of Nuclear Medicine, European Institute for Molecular Imaging (EIMI), Westfälische Wilhelms-Universität Münster, Münster, Germany
| | - René Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Moritz Wildgruber
- Translational Research Imaging Center, Institut für Klinische Radiologie, Universitätsklinikum Münster, Albert-Schweitzer-Campus 1, 48149, Münster, Germany
| | - Fabien Hyafil
- Department of Nuclear Medicine, Bichat University Hospital, AP-HP; INSERM, U-1148, DHU FIRE, University Diderot, Paris, France. .,Département de Médecine Nucléaire, Centre Hospitalier Universitaire Bichat, 46 rue Henri Huchard, 75018, Paris, France.
| | | |
Collapse
|
9
|
Sun Z, Ng CKC, Squelch A. Synchrotron radiation computed tomography assessment of calcified plaques and coronary stenosis with different slice thicknesses and beam energies on 3D printed coronary models. Quant Imaging Med Surg 2019; 9:6-22. [PMID: 30788242 DOI: 10.21037/qims.2018.09.11] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Background To investigate the effect of different slice thicknesses and beam energies on the visualization and assessment of coronary artery stenosis caused by calcified plaques using synchrotron radiation computed tomography (CT) based on 3D printed coronary artery models. Methods Patient-specific 3D coronary models were created based on 3 sample coronary CT angiographic cases with calcified plaques in the left coronary arteries. In addition to the original significant coronary stenosis (>70%) shown on these CT images, stenoses of <50% and >90% were created in the segmented coronary models for simulation of different degrees of stenosis. The coronary lumen and calcification were printed with soft and rigid materials to simulate properties of coronary wall and calcified plaque, respectively. The models were scanned with synchrotron radiation CT with beam energies of 30, 40 and 50 keV and spatial resolution of 0.019×0.019×0.019 mm3 voxel size. Original high-resolution images were reconstructed with slice thicknesses of 0.095, 0.208, 0.302 and 0.491 mm to determine the effect of spatial resolution on plaque and coronary stenosis assessment based on 2D axial and 3D virtual intravascular endoscopy (VIE) images. Results Three coronary artery models were successfully printed with plaques placed in the coronary arteries to simulate different degrees of stenosis. 2D and 3D VIE images reconstructed with slice thicknesses of 0.095, 0.208 and 0.302 mm allowed for accurate assessment of coronary plaques and lumen stenosis with no significant differences (P>0.05). Synchrotron radiation CT images reconstructed with a slice thickness of 0.491 mm resulted in overestimation of coronary stenosis when compared to other images on 2D and 3D VIE views (<50% vs. 55-72%; 70-79% vs. 80-90%) with significant differences (P<0.05). Similarly, irregular plaque appearances were observed on 2D and 3D VIE images with a slice thickness of 0.491 mm when compared to others using thin slice thicknesses. The scanning protocol with beam energy of 30 keV provided optimal visualization of coronary lumen and plaque appearances. Conclusions This study shows the feasibility of using 3D printed coronary artery models to simulate calcifications and different degrees of coronary stenosis. High resolution synchrotron radiation CT imaging with the 30 keV beam energy enables accurate assessment of coronary stenosis in the presence of calcification, thus highlighting the importance of high spatial resolution in the diagnosis of calcified coronary plaques.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, Australia
| | - Curtise K C Ng
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, Australia
| | - Andrew Squelch
- Discipline of Exploration Geophysics, Western Australian School of Mines: Minerals, Energy and Chemical Engineering, Curtin University, Perth, Western Australia, Australia.,Computational Image Analysis Group, Curtin Institute for Computation, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
10
|
Trachet B, Lovric G, Villanueva-Perez P, Aslanidou L, Ferraro M, Logghe G, Stergiopulos N, Segers P. Synchrotron-based phase contrast imaging of cardiovascular tissue in mice—grating interferometry or phase propagation? Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aaeb65] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
11
|
Sun Z, Ng CKC, Sá Dos Reis C. Synchrotron radiation computed tomography versus conventional computed tomography for assessment of four types of stent grafts used for endovascular treatment of thoracic and abdominal aortic aneurysms. Quant Imaging Med Surg 2018; 8:609-620. [PMID: 30140623 DOI: 10.21037/qims.2018.07.05] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Background To determine the accuracy of synchrotron radiation computed tomography (CT) for measurement of stent wire diameters for in vitro simulation of endovascular aneurysm repair by four different types of stent grafts when compared to conventional CT images. Methods This study was performed using an aorta model with implantation of four aortic stent grafts for endovascular treatment of thoracoabdominal and abdominal aortic aneurysms. The aorta model was scanned using synchrotron radiation CT with beam energies ranging from 60 to 90 keV with 10 keV increment at each scan and spatial resolution of 41.6 µm per pixel. Stent wire diameters were measured at the top and body regions of each stent graft based on 2-dimensional (2D) axial and 3-dimensional (3D) reconstruction images, with measurements compared to those obtained from 128-slice CT images which were acquired with slice thickness of 0.5 mm. Results Synchrotron radiation CT images clearly demonstrated stent graft details with accurate assessment of stent wire diameters, with measurements at the top of stent grafts (between 0.32±0.02 and 0.47±0.02 mm) similar to the actual diameters (between 0.32±0.01 and 0.48±0.01 mm) when the beam energies of 70 and 80 keV were used, regardless of the types of stent grafts assessed. A beam energy of 60 keV resulted in stent wires thicker than the actual sizes, although this did not reach statistical significance (P=0.07-0.29), while the beam energy of 90 keV led to stent wires smaller than the actual sizes at the top (P=0.16) and body region (P=0.02) of stent grafts on 2D axial images. The stent wire sizes measured at the body region of stent grafts on 3D synchrotron radiation images (between 0.19±0.02 and 0.43±0.02 mm) were significantly smaller than the actual diameters (P=0.02-0.04). Stent wires were overestimated on conventional CT images with diameters more than 2-fold larger than the actual sizes (P=0.007-0.03) at both top and body regions of all four stent grafts. Conclusions This study further confirms the accuracy of high-resolution synchrotron radiation CT in image visualization and size measurement of different aortic stent grafts with measured wire diameters similar to the actual ones, thus allowing for more accurate assessment of stent wire details for endovascular repair of aortic aneurysms.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, Australia
| | - Curtise K C Ng
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, Australia
| | - Cláudia Sá Dos Reis
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
12
|
Sun Z, Ng CKC. Use of Synchrotron Radiation to Accurately Assess Cross-Sectional Area Reduction of the Aortic Branch Ostia Caused by Suprarenal Stent Wires. J Endovasc Ther 2017; 24:870-879. [PMID: 28922970 DOI: 10.1177/1526602817732315] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
PURPOSE To compare in vivo the use of synchrotron radiation to computed tomography angiography (CTA) for the measurement of cross-sectional area (CSA) reduction of the aortic branch ostia caused by suprarenal stent-graft wires. METHODS This study was performed with a Zenith stent-graft placed in a phantom of the human aorta to simulate treatment of abdominal aortic aneurysm. Synchrotron radiation scans were performed using beam energies between 40 and 100 keV and spatial resolution of 19.88 μm per pixel. CSA reduction of the aortic branch ostia by suprarenal stent wires was calculated based on these exposure factors and compared with measurements from CTA images acquired on a 64-row scanner with slice thicknesses of 1.0, 1.5, and 2.0 mm. RESULTS Images acquired with synchrotron radiation showed <10% of the CSA occupied by stent wires when a single wire crossed a renal artery ostium and <20% for 2 wires crossing a renovisceral branch ostium. The corresponding areas ranged from 24% to 25% for a single wire and from 40% to 48% for double wires crossing the branch ostia when measured on CT images. The stent wire was accurately assessed on synchrotron radiation with a diameter between 0.38±0.01 and 0.53±0.03 mm, which is close to the actual size of 0.47±0.01 mm. The wire diameter measured on CT images was greatly overestimated (1.15±0.01 to 1.57±0.02 mm). CONCLUSION CTA has inferior spatial resolution that hinders accurate assessment of CSA reduction. This experiment demonstrated the superiority of synchrotron radiation over CTA for more accurate assessment of aortic stent wires and CSA reduction of the aortic branch ostia.
Collapse
Affiliation(s)
- Zhonghua Sun
- 1 Department of Medical Radiation Sciences, Curtin University, Perth, Western Australia, Australia
| | - Curtise K C Ng
- 1 Department of Medical Radiation Sciences, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
13
|
Teh I, McClymont D, Zdora MC, Whittington HJ, Davidoiu V, Lee J, Lygate CA, Rau C, Zanette I, Schneider JE. Validation of diffusion tensor MRI measurements of cardiac microstructure with structure tensor synchrotron radiation imaging. J Cardiovasc Magn Reson 2017; 19:31. [PMID: 28279178 PMCID: PMC5345150 DOI: 10.1186/s12968-017-0342-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2016] [Accepted: 02/16/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Diffusion tensor imaging (DTI) is widely used to assess tissue microstructure non-invasively. Cardiac DTI enables inference of cell and sheetlet orientations, which are altered under pathological conditions. However, DTI is affected by many factors, therefore robust validation is critical. Existing histological validation is intrinsically flawed, since it requires further tissue processing leading to sample distortion, is routinely limited in field-of-view and requires reconstruction of three-dimensional volumes from two-dimensional images. In contrast, synchrotron radiation imaging (SRI) data enables imaging of the heart in 3D without further preparation following DTI. The objective of the study was to validate DTI measurements based on structure tensor analysis of SRI data. METHODS One isolated, fixed rat heart was imaged ex vivo with DTI and X-ray phase contrast SRI, and reconstructed at 100 μm and 3.6 μm isotropic resolution respectively. Structure tensors were determined from the SRI data and registered to the DTI data. RESULTS Excellent agreement in helix angles (HA) and transverse angles (TA) was observed between the DTI and structure tensor synchrotron radiation imaging (STSRI) data, where HADTI-STSRI = -1.4° ± 23.2° and TADTI-STSRI = -1.4° ± 35.0° (mean ± 1.96 standard deviation across all voxels in the left ventricle). STSRI confirmed that the primary eigenvector of the diffusion tensor corresponds with the cardiomyocyte long-axis across the whole myocardium. CONCLUSIONS We have used STSRI as a novel and high-resolution gold standard for the validation of DTI, allowing like-with-like comparison of three-dimensional tissue structures in the same intact heart free of distortion. This represents a critical step forward in independently verifying the structural basis and informing the interpretation of cardiac DTI data, thereby supporting the further development and adoption of DTI in structure-based electro-mechanical modelling and routine clinical applications.
Collapse
Affiliation(s)
- Irvin Teh
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
- Leeds Institute of Cardiovascular & Metabolic Medicine, University of Leeds, Leeds, UK
| | - Darryl McClymont
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Marie-Christine Zdora
- Diamond Light Source, Didcot, UK
- Department of Physics and Astronomy, University College London, London, UK
| | - Hannah J. Whittington
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Valentina Davidoiu
- Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, UK
| | - Jack Lee
- Division of Imaging Sciences and Biomedical Engineering, King’s College London, London, UK
| | - Craig A. Lygate
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Christoph Rau
- Diamond Light Source, Didcot, UK
- University of Manchester, Manchester, UK
- Feinberg School of Medicine, Northwestern University, Chicago, USA
| | | | - Jürgen E. Schneider
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
- Leeds Institute of Cardiovascular & Metabolic Medicine, University of Leeds, Leeds, UK
| |
Collapse
|