For: Shi YJ, Pei J, Zhang J, Niu JL, Zhang H, Guo SR, Li ZH, Yuan GY. Enhanced corrosion resistance and cytocompatibility of biodegradable Mg alloys by introduction of Mg(OH)2 particles into poly (L-lactic acid) coating. Sci Rep 2017;7:41796. [PMID: 28150751 DOI: 10.1038/srep41796] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Accepted: 12/28/2016] [Indexed: 01/19/2023]  Open
Number Cited by Other Article(s)
1
Wen KC, Li ZA, Liu JH, Zhang C, Zhang F, Li FQ. Recent developments in ureteral stent: Substrate material, coating polymer and technology, therapeutic function. Colloids Surf B Biointerfaces 2024;238:113916. [PMID: 38636438 DOI: 10.1016/j.colsurfb.2024.113916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Revised: 03/21/2024] [Accepted: 04/11/2024] [Indexed: 04/20/2024]
2
Pan C, Xu R, Chen J, Zhang Q, Deng L, Hong Q. A CO-releasing coating based on carboxymethyl chitosan-functionalized graphene oxide for improving the anticorrosion and biocompatibility of magnesium alloy stent materials. Int J Biol Macromol 2024;271:132487. [PMID: 38768910 DOI: 10.1016/j.ijbiomac.2024.132487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/12/2024] [Accepted: 05/16/2024] [Indexed: 05/22/2024]
3
Liu D, Yang K, Chen S. Development and Future Trends of Protective Strategies for Magnesium Alloy Vascular Stents. MATERIALS (BASEL, SWITZERLAND) 2023;17:68. [PMID: 38203922 PMCID: PMC10779993 DOI: 10.3390/ma17010068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 12/09/2023] [Accepted: 12/20/2023] [Indexed: 01/12/2024]
4
Wu C, He X, Zhu Y, Weng W, Cheng K, Wang D, Chen Z. Electrochemical deposition of Ppy/Dex/ECM coatings and their regulation on cellular responses through electrical controlled drug release. Colloids Surf B Biointerfaces 2023;222:113016. [PMID: 36427406 DOI: 10.1016/j.colsurfb.2022.113016] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 11/06/2022] [Accepted: 11/10/2022] [Indexed: 11/13/2022]
5
Fattah-alhosseini A, Chaharmahali R, Rajabi A, Babaei K, Kaseem M. Performance of PEO/Polymer Coatings on the Biodegradability, Antibacterial Effect and Biocompatibility of Mg-Based Materials. J Funct Biomater 2022;13:jfb13040267. [PMID: 36547527 PMCID: PMC9781375 DOI: 10.3390/jfb13040267] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 11/19/2022] [Accepted: 11/26/2022] [Indexed: 12/03/2022]  Open
6
Helal Hossain MD, Hossain N, Asaduzzaman Chowdhury M, Arefin Kowser M, Masud Rana M. Surface Synthesization of Magnesium Alloys for Improving Corrosion Resistance and Implant Applications. ARAB J CHEM 2022. [DOI: 10.1016/j.arabjc.2022.104465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]  Open
7
Park S, Lee H, Kim HE, Jung HD, Jang TS. Bifunctional poly (l-lactic acid)/hydrophobic silica nanocomposite layer coated on magnesium stents for enhancing corrosion resistance and endothelial cell responses. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021;127:112239. [PMID: 34225879 DOI: 10.1016/j.msec.2021.112239] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 05/25/2021] [Accepted: 06/02/2021] [Indexed: 11/28/2022]
8
Li H, Song W, Cui X, Li Y, Hou B, Zhang X, Wang Y, Cheng L, Zhang P, Li J. AgInS2 and graphene co-sensitized TiO2 photoanodes for photocathodic protection of Q235 carbon steel under visible light. NANOTECHNOLOGY 2020;31:305704. [PMID: 32240986 DOI: 10.1088/1361-6528/ab85eb] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
9
Zhu Y, Zheng L, Liu W, Qin L, Ngai T. Poly(l-lactic acid) (PLLA)/MgSO4·7H2O Composite Coating on Magnesium Substrates for Corrosion Protection and Cytocompatibility Promotion. ACS APPLIED BIO MATERIALS 2020;3:1364-1373. [DOI: 10.1021/acsabm.9b00983] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
10
Tezcan F, Mahmood A, Kardaş G. The investigation of Cu2O electrochemical deposition time effect on ZnO for water splitting. J Mol Struct 2019. [DOI: 10.1016/j.molstruc.2019.05.052] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
11
Zhang X, Dai J, Dong Q, Ba Z, Wu Y. Corrosion behavior and mechanical degradation of as‐extruded Mg–Gd–Zn–Zr alloys for orthopedic application. J Biomed Mater Res B Appl Biomater 2019;108:698-708. [DOI: 10.1002/jbm.b.34424] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 05/10/2019] [Accepted: 05/17/2019] [Indexed: 12/13/2022]
12
In-Vivo Corrosion Characterization and Assessment of Absorbable Metal Implants. COATINGS 2019. [DOI: 10.3390/coatings9050282] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
13
Vitale F, Shen W, Driscoll N, Burrell JC, Richardson AG, Adewole O, Murphy B, Ananthakrishnan A, Oh H, Wang T, Lucas TH, Cullen DK, Allen MG, Litt B. Biomimetic extracellular matrix coatings improve the chronic biocompatibility of microfabricated subdural microelectrode arrays. PLoS One 2018;13:e0206137. [PMID: 30383805 PMCID: PMC6211660 DOI: 10.1371/journal.pone.0206137] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Accepted: 10/08/2018] [Indexed: 01/15/2023]  Open
14
Li H, Peng F, Wang D, Qiao Y, Xu D, Liu X. Layered double hydroxide/poly-dopamine composite coating with surface heparinization on Mg alloys: improved anticorrosion, endothelialization and hemocompatibility. Biomater Sci 2018;6:1846-1858. [PMID: 29789824 DOI: 10.1039/c8bm00298c] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
15
Yang G, Yang H, Shi L, Wang T, Zhou W, Zhou T, Han W, Zhang Z, Lu W, Hu J. Enhancing Corrosion Resistance, Osteoinduction, and Antibacterial Properties by Zn/Sr Additional Surface Modification of Magnesium Alloy. ACS Biomater Sci Eng 2018;4:4289-4298. [PMID: 33418825 DOI: 10.1021/acsbiomaterials.8b00781] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
16
Li LY, Cui LY, Zeng RC, Li SQ, Chen XB, Zheng Y, Kannan MB. Advances in functionalized polymer coatings on biodegradable magnesium alloys - A review. Acta Biomater 2018;79:23-36. [PMID: 30149212 DOI: 10.1016/j.actbio.2018.08.030] [Citation(s) in RCA: 136] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 08/21/2018] [Accepted: 08/23/2018] [Indexed: 01/20/2023]
17
Shen W, Das S, Vitale F, Richardson A, Ananthakrishnan A, Struzyna LA, Brown DP, Song N, Ramkumar M, Lucas T, Cullen DK, Litt B, Allen MG. Microfabricated intracortical extracellular matrix-microelectrodes for improving neural interfaces. MICROSYSTEMS & NANOENGINEERING 2018;4:30. [PMID: 31057918 PMCID: PMC6220172 DOI: 10.1038/s41378-018-0030-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 05/30/2018] [Accepted: 08/05/2018] [Indexed: 05/30/2023]
18
Hermawan H. Updates on the research and development of absorbable metals for biomedical applications. Prog Biomater 2018;7:93-110. [PMID: 29790132 PMCID: PMC6068061 DOI: 10.1007/s40204-018-0091-4] [Citation(s) in RCA: 87] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Accepted: 05/17/2018] [Indexed: 12/12/2022]  Open
19
Chen Y, Ye SH, Sato H, Zhu Y, Shanov V, Tiasha T, D'Amore A, Luketich S, Wan G, Wagner WR. Hybrid scaffolds of Mg alloy mesh reinforced polymer/extracellular matrix composite for critical-sized calvarial defect reconstruction. J Tissue Eng Regen Med 2018;12:1374-1388. [DOI: 10.1002/term.2668] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 02/07/2018] [Accepted: 04/11/2018] [Indexed: 12/20/2022]
20
Ang HY, Huang YY, Lim ST, Wong P, Joner M, Foin N. Mechanical behavior of polymer-based vs. metallic-based bioresorbable stents. J Thorac Dis 2017;9:S923-S934. [PMID: 28894598 PMCID: PMC5583085 DOI: 10.21037/jtd.2017.06.30] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Accepted: 05/18/2017] [Indexed: 11/06/2022]