1
|
Mao L, Han Z, Xing X, Hu Z, She L, Song C. Development of implantable electrode based on bioresorbable Mg alloy for tissue welding application. Sci Rep 2024; 14:16110. [PMID: 38997318 PMCID: PMC11245471 DOI: 10.1038/s41598-024-67077-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Accepted: 07/08/2024] [Indexed: 07/14/2024] Open
Abstract
An implantable electrode based on bioresorbable Mg-Nd-Zn-Zr alloy was developed for next-generation radiofrequency (RF) tissue welding application, aiming to reduce thermal damage and enhance anastomotic strength. The Mg alloy electrode was designed with different structural features of cylindrical surface (CS) and continuous long ring (LR) in the welding area, and the electrothermal simulations were studied by finite element analysis (FEA). Meanwhile, the temperature variation during tissue welding was monitored and the anastomotic strength of welded tissue was assessed by measuring the avulsion force and burst pressure. FEA results showed that the mean temperature in the welding area and the proportion of necrotic tissue were significantly reduced when applying an alternating current of 110 V for 10 s to the LR electrode. In the experiment of tissue welding ex vivo, the maximum and mean temperatures of tissues welded by the LR electrode were also significantly reduced and the anastomotic strength of welded tissue could be obviously improved. Overall, an ideal welding temperature and anastomotic strength which meet the clinical requirement can be obtained after applying the LR electrode, suggesting that Mg-Nd-Zn-Zr alloy with optimal structure design shows great potential to develop implantable electrode for next-generation RF tissue welding application.
Collapse
Affiliation(s)
- Lin Mao
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Zhengyi Han
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Xupo Xing
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Zhongxin Hu
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Langlang She
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Chengli Song
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| |
Collapse
|
2
|
Hussain M, Khan SM, Shafiq M, Abbas N, Sajjad U, Hamid K. Advances in biodegradable materials: Degradation mechanisms, mechanical properties, and biocompatibility for orthopedic applications. Heliyon 2024; 10:e32713. [PMID: 39027458 PMCID: PMC11254538 DOI: 10.1016/j.heliyon.2024.e32713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 06/06/2024] [Accepted: 06/07/2024] [Indexed: 07/20/2024] Open
Abstract
Mg-based and Zn-based biodegradable materials have the potential to become the next-generation implant materials to treat bone diseases, because of their desired degradation and mechanical properties. This article reviews the status of these implant materials. The required properties of biodegradable materials such as biodegradability, mechanical properties, and biocompatibility for performance evaluation were briefly discussed. The influence of fabrication techniques, microstructure, alloying elements, and post-processing techniques on the properties of Mg and Zn-based materials was addressed. The degradation mechanism by dissolution, oxidation, and interaction with human body cells was discussed. The biocompatibility of Mg and Zn-based biodegradable materials was analyzed. The significance of in vitro and in vivo biocompatibility testing was highlighted, emphasizing the superiority of in vivo results over cell line studies. This article identifies the many Mg and Zn-based biodegradable materials and summarizes the key findings.
Collapse
Affiliation(s)
- Muzamil Hussain
- Institute of Polymer & Textile Engineering, University of the Punjab, Lahore, 54000, Pakistan
| | - Shahzad Maqsood Khan
- Institute of Polymer & Textile Engineering, University of the Punjab, Lahore, 54000, Pakistan
| | - Muhammad Shafiq
- Institute of Polymer & Textile Engineering, University of the Punjab, Lahore, 54000, Pakistan
| | - Naseem Abbas
- Department of Mechanical Engineering, Sejong University, Seoul, 05006, Republic of Korea
| | - Uzair Sajjad
- Department of Energy and Refrigerating Air-Conditioning Engineering, National Taipei University of Technology, Taipei, 10608, Taiwan
| | - Khalid Hamid
- Process and Power Research Group, Department of Energy and Process Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| |
Collapse
|
3
|
Hassan N, Krieg T, Kopp A, Bach AD, Kröger N. Challenges and Pitfalls of Research Designs Involving Magnesium-Based Biomaterials: An Overview. Int J Mol Sci 2024; 25:6242. [PMID: 38892430 PMCID: PMC11172609 DOI: 10.3390/ijms25116242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 05/31/2024] [Accepted: 06/01/2024] [Indexed: 06/21/2024] Open
Abstract
Magnesium-based biomaterials hold remarkable promise for various clinical applications, offering advantages such as reduced stress-shielding and enhanced bone strengthening and vascular remodeling compared to traditional materials. However, ensuring the quality of preclinical research is crucial for the development of these implants. To achieve implant success, an understanding of the cellular responses post-implantation, proper model selection, and good study design are crucial. There are several challenges to reaching a safe and effective translation of laboratory findings into clinical practice. The utilization of Mg-based biomedical devices eliminates the need for biomaterial removal surgery post-healing and mitigates adverse effects associated with permanent biomaterial implantation. However, the high corrosion rate of Mg-based implants poses challenges such as unexpected degradation, structural failure, hydrogen evolution, alkalization, and cytotoxicity. The biocompatibility and degradability of materials based on magnesium have been studied by many researchers in vitro; however, evaluations addressing the impact of the material in vivo still need to be improved. Several animal models, including rats, rabbits, dogs, and pigs, have been explored to assess the potential of magnesium-based materials. Moreover, strategies such as alloying and coating have been identified to enhance the degradation rate of magnesium-based materials in vivo to transform these challenges into opportunities. This review aims to explore the utilization of Mg implants across various biomedical applications within cellular (in vitro) and animal (in vivo) models.
Collapse
Affiliation(s)
- Nourhan Hassan
- Department of Plastic, Reconstructive and Aesthetic Surgery, University Hospital Cologne, 50937 Cologne, Germany
- Institute for Laboratory Animal Science and Experimental Surgery, University of Aachen Medical Center, Faculty of Medicine, RWTH-Aachen University, 52074 Aachen, Germany
- Biotechnology Department, Faculty of Science, Cairo University, Giza 12613, Egypt
| | - Thomas Krieg
- Translational Matrix Biology, Medical Faculty, University of Cologne, 50937 Cologne, Germany
- Cologne Excellence Cluster on Cellular Stress Responses in Aging-Associated Diseases (CECAD), University of Cologne, 50937 Cologne, Germany
- Center for Molecular Medicine (CMMC), University of Cologne, 50937 Cologne, Germany
| | | | - Alexander D. Bach
- Department of Plastic, Aesthetic and Hand Surgery, St. Antonius Hospital Eschweiler, 52249 Eschweiler, Germany
| | - Nadja Kröger
- Institute for Laboratory Animal Science and Experimental Surgery, University of Aachen Medical Center, Faculty of Medicine, RWTH-Aachen University, 52074 Aachen, Germany
- Department of Plastic, Aesthetic and Hand Surgery, St. Antonius Hospital Eschweiler, 52249 Eschweiler, Germany
| |
Collapse
|
4
|
Nam NN, Tran NKS, Nguyen TT, Trai NN, Thuy NP, Do HDK, Tran NHT, Trinh KTL. Classification and application of metal-based nanoantioxidants in medicine and healthcare. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2024; 15:396-415. [PMID: 38633767 PMCID: PMC11022389 DOI: 10.3762/bjnano.15.36] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 03/15/2024] [Indexed: 04/19/2024]
Abstract
Antioxidants play an important role in the prevention of oxidative stress and have been widely used in medicine and healthcare. However, natural antioxidants have several limitations such as low stability, difficult long-term storage, and high cost of large-scale production. Along with significant advances in nanotechnology, nanomaterials have emerged as a promising solution to improve the limitations of natural antioxidants because of their high stability, easy storage, time effectiveness, and low cost. Among various types of nanomaterials exhibiting antioxidant activity, metal-based nanoantioxidants show excellent reactivity because of the presence of an unpaired electron in their atomic structure. In this review, we summarize some novel metal-based nanoantioxidants and classify them into two main categories, namely chain-breaking and preventive antioxidant nanomaterials. In addition, the applications of antioxidant nanomaterials in medicine and healthcare are also discussed. This review provides a deeper understanding of the mechanisms of metal-based nanoantioxidants and a guideline for using these nanomaterials in medicine and healthcare.
Collapse
Affiliation(s)
- Nguyen Nhat Nam
- Applied Biology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Nguyen Khoi Song Tran
- College of Korean Medicine, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| | - Tan Tai Nguyen
- Department of Materials Science, School of Applied Chemistry, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Nguyen Ngoc Trai
- Applied Biology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Nguyen Phuong Thuy
- Applied Biology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 70000, Vietnam
| | - Nhu Hoa Thi Tran
- Faculty of Materials Science and Technology, University of Science, Ho Chi Minh City, Vietnam
- Vietnam National University Ho Chi Minh City, Vietnam
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
5
|
Li M, Jin M, Yang H. Remodelers of the vascular microenvironment: The effect of biopolymeric hydrogels on vascular diseases. Int J Biol Macromol 2024; 264:130764. [PMID: 38462100 DOI: 10.1016/j.ijbiomac.2024.130764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 01/31/2024] [Accepted: 03/07/2024] [Indexed: 03/12/2024]
Abstract
Vascular disease is the leading health problem worldwide. Vascular microenvironment encompasses diverse cell types, including those within the vascular wall, blood cells, stromal cells, and immune cells. Initiation of the inflammatory state of the vascular microenvironment and changes in its mechanics can profoundly affect vascular homeostasis. Biomedical materials play a crucial role in modern medicine, hydrogels, characterized by their high-water content, have been increasingly utilized as a three-dimensional interaction network. In recent times, the remarkable progress in utilizing hydrogels and understanding vascular microenvironment have enabled the treatment of vascular diseases. In this review, we give an emphasis on the utilization of hydrogels and their advantages in the various vascular diseases including atherosclerosis, aneurysm, vascular ulcers of the lower limbs and myocardial infarction. Further, we highlight the importance and advantages of hydrogels as artificial microenvironments.
Collapse
Affiliation(s)
- Minhao Li
- School of Intelligent Medicine, China Medical University, No.77, Puhe Road, Shenyang 110122, Liaoning Province, China
| | - Meiqi Jin
- School of Intelligent Medicine, China Medical University, No.77, Puhe Road, Shenyang 110122, Liaoning Province, China
| | - Huazhe Yang
- School of Intelligent Medicine, China Medical University, No.77, Puhe Road, Shenyang 110122, Liaoning Province, China.
| |
Collapse
|
6
|
Xing X, Song C. A novel electrode for reducing tissue thermal damage in radiofrequency-induced intestinal anastomosis. MINIM INVASIV THER 2024; 33:80-89. [PMID: 38147884 DOI: 10.1080/13645706.2023.2297774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 11/28/2023] [Indexed: 12/28/2023]
Abstract
PURPOSE This study aimed to design a novel electrode for reducing tissue thermal damage in radiofrequency-induced intestinal anastomosis. MATERIAL AND METHODS We developed and compared two electrodes (Ring electrode, and Plum electrode with reduced section of the middle fusion area by nearly 80% arising from novel structural design) by performing ex-vivo experiments and finite element analysis. RESULTS In contrast to the Ring electrode group, slightly higher mean strength is acquired with the tensile force and burst pressure results increasing from 9.7 ± 1.47 N, 84.0 ± 5.99 mmHg to 11.1 ± 1.71 N, 89.4 ± 6.60 mmHg, respectively, as well as a significant reduction in tissue thermal damage for the Plum electrode group, with compression pressure of 20 kPa, RF energy of 120 W and welding duration of 8 s applied to the target regions to achieve anastomosis. Besides, the novel structural design of the Plum electrode can counteract the tension generated by intestinal peristalsis and enhance the biomechanical strength of the anastomotic area. The histological observation showed that the fusion area of the two-layer intestinal tissue is tightly connected with decreased thickness. CONCLUSION The novel electrode (Plum electrode) could reduce tissue thermal damage in radiofrequency-induced intestinal anastomosis.
Collapse
Affiliation(s)
- Xupo Xing
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Chengli Song
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| |
Collapse
|
7
|
Duan X, Yang Y, Zhang T, Zhu B, Wei G, Li H. Research progress of metal biomaterials with potential applications as cardiovascular stents and their surface treatment methods to improve biocompatibility. Heliyon 2024; 10:e25515. [PMID: 38375258 PMCID: PMC10875388 DOI: 10.1016/j.heliyon.2024.e25515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 01/23/2024] [Accepted: 01/29/2024] [Indexed: 02/21/2024] Open
Abstract
Facing the growing issue of cardiovascular diseases, metallic materials with higher tensile strength and fatigue resistance play an important role in treating diseases. This review lists the advantages and drawbacks of commonly used medical metallic materials for vascular stents. To avoid post-procedural threats such as thrombosis and in-stent restenosis, surface treatments, and coating methods have been used to further improve the biocompatibility of these materials. Surface treatments including laser, plasma treatment, polishing, oxidization, and fluorination can improve biocompatibility by modifying the surface charges, surface morphology, and surface properties of the material. Coating methods based on polymer coatings, carbon-based coatings, and drug-functional coatings can regulate the surface properties, and also serve as an effective barrier to the interaction of metallic biomaterial surfaces with biomolecules, which can be used to improve corrosion resistance and stability, as well as improve their biocompatibility. Biocompatibility serves as the most fundamental property of cardiovascular stents, and maintaining the excellent and stable biocompatibility of cardiovascular stent surfaces is a current research bottleneck. Few reviews have been published on metallic biomaterials as cardiovascular stents and their surface treatments. For the purpose of advancing research on cardiovascular stents, common metal biomaterials, surface treatment methods, and coating methods to improve biocompatibility and comprehensive properties of the materials are described in this review. Finally, we suggest future directions for stent development, including continuously improving the durability and stability of permanent stents, accelerating the development of biodegradable stents, and strengthening feedback to improve the safety and reliability of cardiovascular stents.
Collapse
Affiliation(s)
- Xuejia Duan
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
| | - Yumeng Yang
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Tianji Zhang
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
- Key Laboratory of Chemical Metrology and Applications on Nutrition and Health for State Market Regulation, China
| | - Benfeng Zhu
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Guoying Wei
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Hongmei Li
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
- Key Laboratory of Chemical Metrology and Applications on Nutrition and Health for State Market Regulation, China
| |
Collapse
|
8
|
Mohanta M, Ramdhun Y, Thirugnanam A, Gupta R, Verma D, Deepak T, Babu AR. Biodegradable AZ91 magnesium alloy/sirolimus/poly D, L-lactic-co-glycolic acid-based substrate for cardiovascular device application. J Biomed Mater Res B Appl Biomater 2024; 112:e35350. [PMID: 37966681 DOI: 10.1002/jbm.b.35350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 09/26/2023] [Accepted: 10/30/2023] [Indexed: 11/16/2023]
Abstract
Biodegradable drug-eluting stents (DESs) are gaining importance owing to their attractive features, such as complete drug release to the target site. Magnesium (Mg) alloys are promising materials for future biodegradable DESs. However, there are few explorations using biodegradable Mg for cardiovascular stent application. In this present study, sirolimus-loaded poly D, L-lactic-co-glycolic acid (PLGA)-coated/ sirolimus-fixed/AZ91 Mg alloy-based substrate was developed via a layer-by-layer approach for cardiovascular stent application. The AZ91 Mg alloy was prepared through the squeeze casting technique. The casted AZ91 Mg alloy (Mg) was alkali-treated to provide macroporous networks to hold the sirolimus and PLGA layers. The systematic characterization was investigated via electrochemical, optical, physicochemical, and in-vitro biological characteristics. The presence of the Mg17 Al12 phase in the Mg sample was found in the x-ray diffraction system (XRD) spectrum which influences the corrosion behavior of the developed substrate. The alkali treatment increases the substrate's hydrophilicity which was confirmed through static contact angle measurement. The anti-corrosion characteristic of casted-AZ91 Mg alloy (Mg) was slightly less than the sirolimus-loaded PLGA-coated alkali-treated AZ91 Mg alloy (Mg/Na/S/P) substrate. However, dissolution rates for both substrates were found to be controlled at cell culture conditions. Radiographic densities of AZ91 Mg alloy substrates (Mg, Mg/Na, and Mg/Na/S/P) were measured to be 0.795 ± 0.015, 0.742 ± 0.01, and 0.712 ± 0.017, respectively. The star-shaped structure of 12% sirolimus/PLGA ensures the bioavailability of the drugs. Sirolimus release kinetic was fitted up to 80% with the "Higuchi model" for Mg samples, whereas Mg/Na/S/P showed 45% fitting with a zero-order mechanism. The Mg/Na/S/P substrate showed a 70% antithrombotic effect compared to control. Further, alkali treatment enhances the antibacterial characteristic of AZ91 Mg alloy. Also, the alkali-treated sirolimus-loaded substrates (Mg/Na/S and Mg/Na/S/P) inhibit the valvular interstitial cell's growth significantly in in-vitro. Hence, the results imply that sirolimus-loaded PLGA-coated AZ91 Mg alloy-based substrate can be a potential candidate for cardiovascular stent application.
Collapse
Affiliation(s)
- Monalisha Mohanta
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha, India
| | - Yugesh Ramdhun
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha, India
| | - Arunachalam Thirugnanam
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha, India
| | - Ritvesh Gupta
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha, India
| | - Devendra Verma
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha, India
| | - Thirumalai Deepak
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha, India
| | - Anju R Babu
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, Odisha, India
| |
Collapse
|
9
|
Tabares Ocampo J, Marín Valencia V, Robledo SM, Upegui Zapata YA, Restrepo Múnera LM, Echeverría F, Echeverry-Rendón M. Biological response of degradation products of PEO-modified magnesium on vascular tissue cells, hemocompatibility and its influence on the inflammatory response. BIOMATERIALS ADVANCES 2023; 154:213645. [PMID: 37806213 DOI: 10.1016/j.bioadv.2023.213645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 09/06/2023] [Accepted: 09/29/2023] [Indexed: 10/10/2023]
Abstract
Cardiovascular stenting is the most widely used therapy to treat coronary artery disease caused by partial or total obstruction of the artery due to atherosclerotic plaque formation, with potentially fatal effects. There are different types of stents: bare metal stents, drug-eluting stents, bioabsorbable stents and dual therapy stents. However, they can lead to long-term complications, such as in-stent restenosis and late thrombosis. To reduce these adverse effects, research has focused on biodegradable metallic stents, since they retain the mechanical properties necessary to contain the injured artery while it is being repaired and, once their function has been fulfilled, the stent degrades without altering the system or compromising the patient's health. In this work we have evaluated the biological response of the degradation products of a bare Mg based biomaterial surface-modified by the plasma electrolytic oxidation (PEO) method on vascular tissue cells, hemocompatibility and inflammatory response. The results obtained are compatible with a biosafe material for future use as a cardiovascular implant, but it is necessary to continue with in vivo and mechanical properties tests to ensure and guarantee its use. SIGNIFICANCE STATEMENT: The development of fully bioresorbable stents is a promising alternative for the management of coronary artery disease without causing long-term problems at the implantation site. In this work, the hematological and immunological biocompatibility of bare Mg modified superficially by plasma electrolytic oxidation (PEO-Mg) was evaluated by in vitro and ex vivo assays. PEO-Mg was found to be compatible with blood and immune components surrounding the implantation site with no signs of toxicity to endothelial cells, macrophages, and arterial tissue. In addition, degradation products of PEO-Mg are eliminated by phagocytosis. However, an in-depth study of the physical and mechanical properties and in vivo biocompatibility must be carried out for its future use as a biomedical implant.
Collapse
Affiliation(s)
| | - Valentina Marín Valencia
- Centro de Investigación, Innovación y Desarrollo de Materiales CIDEMAT, Facultad de Ingeniería, Universidad de Antioquia, Medellín, Colombia
| | - Sara M Robledo
- PECET-Facultad de Medicina, Universidad de Antioquia UdeA, Medellín, Colombia
| | | | - Luz Marina Restrepo Múnera
- Grupo Investigación Ingeniería de Tejidos terapias celulares GITTC, Facultad de Medicina, Universidad de Antioquia UdeA, Medellín, Colombia
| | - Félix Echeverría
- Centro de Investigación, Innovación y Desarrollo de Materiales CIDEMAT, Facultad de Ingeniería, Universidad de Antioquia, Medellín, Colombia
| | | |
Collapse
|
10
|
Zhou Y, Wang D, Yang Y. Biodegradation and Cell Behavior of a Mg-Based Composite with Mesoporous Bioglass. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6248. [PMID: 37763526 PMCID: PMC10533000 DOI: 10.3390/ma16186248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/13/2023] [Accepted: 09/14/2023] [Indexed: 09/29/2023]
Abstract
Biodegradable magnesium (Mg) and its alloys show tremendous potential as orthopedic materials. Nevertheless, the fast degradation and insufficient osteogenic properties hinder their applications. In this study, mesoporous bioglass (MBG) with an ordered branch-like structure was synthesized via a modified sol-gel method and showed a high specific surface area of 656.45 m2/g. A Mg-based composite was prepared by introducing the MBG into a Mg matrix via powder metallurgy. Degradation tests showed that the introduction of MBG increased the adsorption sites for Ca and P ions, thus promoting the formation of a Ca-P protective layer on the Mg matrix. The Ca-P protective layer became thick and dense with an increase in the immersion time, improving the protection ability of the Mg matrix, as proven by electrochemical impedance spectroscopy measurements. Meanwhile, the Mg-based composite also exhibited excellent biocompatibility and osteogenic properties. This study demonstrated the advantages of MBG in the preparation of Mg-based bone implants and validated the feasibility of improving Mg matrix corrosion resistance and enhancing osteogenesis by introducing MBG.
Collapse
Affiliation(s)
- Yan Zhou
- Key Laboratory of Construction Hydraulic Robots, Anhui Higher Education Institutes, Tongling University, Tongling 244061, China;
| | - Dongsheng Wang
- Key Laboratory of Construction Hydraulic Robots, Anhui Higher Education Institutes, Tongling University, Tongling 244061, China;
| | - Youwen Yang
- Key Laboratory of Construction Hydraulic Robots, Anhui Higher Education Institutes, Tongling University, Tongling 244061, China;
- Institute of Additive Manufacturing, Jiangxi University of Science and Technology, Nanchang 330013, China
| |
Collapse
|
11
|
Chen X, Xia Y, Shen S, Wang C, Zan R, Yu H, Yang S, Zheng X, Yang J, Suo T, Gu Y, Zhang X. Research on the Current Application Status of Magnesium Metal Stents in Human Luminal Cavities. J Funct Biomater 2023; 14:462. [PMID: 37754876 PMCID: PMC10532415 DOI: 10.3390/jfb14090462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/01/2023] [Accepted: 09/06/2023] [Indexed: 09/28/2023] Open
Abstract
The human body comprises various tubular structures that have essential functions in different bodily systems. These structures are responsible for transporting food, liquids, waste, and other substances throughout the body. However, factors such as inflammation, tumors, stones, infections, or the accumulation of substances can lead to the narrowing or blockage of these tubular structures, which can impair the normal function of the corresponding organs or tissues. To address luminal obstructions, stenting is a commonly used treatment. However, to minimize complications associated with the long-term implantation of permanent stents, there is an increasing demand for biodegradable stents (BDS). Magnesium (Mg) metal is an exceptional choice for creating BDS due to its degradability, good mechanical properties, and biocompatibility. Currently, the Magmaris® coronary stents and UNITY-BTM biliary stent have obtained Conformité Européene (CE) certification. Moreover, there are several other types of stents undergoing research and development as well as clinical trials. In this review, we discuss the required degradation cycle and the specific properties (anti-inflammatory effect, antibacterial effect, etc.) of BDS in different lumen areas based on the biocompatibility and degradability of currently available magnesium-based scaffolds. We also offer potential insights into the future development of BDS.
Collapse
Affiliation(s)
- Xiang Chen
- School of Medicine, Anhui University of Science and Technology, Huainan 232000, China;
| | - Yan Xia
- School of Stomatology, Anhui Medical College, Hefei 230601, China;
| | - Sheng Shen
- Department of Biliary Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China; (S.S.); (R.Z.); (T.S.)
- Shanghai Engineering Research Center of Biliary Tract Minimal Invasive Surgery and Materials, Shanghai 200032, China;
| | - Chunyan Wang
- Shanghai Engineering Research Center of Biliary Tract Minimal Invasive Surgery and Materials, Shanghai 200032, China;
- Department of General Surgery, Shanghai Xuhui Central Hospital, Shanghai 200031, China
| | - Rui Zan
- Department of Biliary Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China; (S.S.); (R.Z.); (T.S.)
- Shanghai Engineering Research Center of Biliary Tract Minimal Invasive Surgery and Materials, Shanghai 200032, China;
| | - Han Yu
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (S.Y.)
| | - Shi Yang
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (S.Y.)
| | - Xiaohong Zheng
- Department of Hepatopancreatobiliary Surgery, Huainan Xinhua Hospital Affiliated to Anhui University of Science and Technology, Huainan 232000, China; (X.Z.); (J.Y.)
| | - Jiankang Yang
- Department of Hepatopancreatobiliary Surgery, Huainan Xinhua Hospital Affiliated to Anhui University of Science and Technology, Huainan 232000, China; (X.Z.); (J.Y.)
| | - Tao Suo
- Department of Biliary Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China; (S.S.); (R.Z.); (T.S.)
- Shanghai Engineering Research Center of Biliary Tract Minimal Invasive Surgery and Materials, Shanghai 200032, China;
| | - Yaqi Gu
- School of Medicine, Anhui University of Science and Technology, Huainan 232000, China;
- Department of Hepatopancreatobiliary Surgery, Huainan Xinhua Hospital Affiliated to Anhui University of Science and Technology, Huainan 232000, China; (X.Z.); (J.Y.)
| | - Xiaonong Zhang
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (S.Y.)
| |
Collapse
|
12
|
Wu M, Xun M, Chen Y. Adaptation of Vascular Smooth Muscle Cell to Degradable Metal Stent Implantation. ACS Biomater Sci Eng 2023. [PMID: 37364226 DOI: 10.1021/acsbiomaterials.3c00637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2023]
Abstract
Iron-, magnesium-, or zinc-based metal vessel stents support vessel expansion at the period early after implantation and degrade away after vascular reconstruction, eliminating the side effects due to the long stay of stent implants in the body and the risks of restenosis and neoatherosclerosis. However, emerging evidence has indicated that their degradation alters the vascular microenvironment and induces adaptive responses of surrounding vessel cells, especially vascular smooth muscle cells (VSMCs). VSMCs are highly flexible cells that actively alter their phenotype in response to the stenting, similarly to what they do during all stages of atherosclerosis pathology, which significantly influences stent performance. This Review discusses how biodegradable metal stents modify vascular conditions and how VSMCs respond to various chemical, biological, and physical signals attributable to stent implantation. The focus is placed on the phenotypic adaptation of VSMCs and the clinical complications, which highlight the importance of VSMC transformation in future stent design.
Collapse
Affiliation(s)
- Meichun Wu
- Hengyang Medical School, University of South China, Hengyang, Hunan 410001, China
- School of Nursing, University of South China, Hengyang, Hunan 410001, China
| | - Min Xun
- Institute of Pharmacy and Pharmacology, School of Pharmaceutical Science, University of South China, Hengyang, Hunan 410001, China
| | - Yuping Chen
- Hengyang Medical School, University of South China, Hengyang, Hunan 410001, China
- Institute of Pharmacy and Pharmacology, School of Pharmaceutical Science, University of South China, Hengyang, Hunan 410001, China
| |
Collapse
|
13
|
Aboutalebianaraki N, Zeblisky P, Sarker MD, Jeyaranjan A, Sakthivel TS, Fu Y, Lucchi J, Baudelet M, Seal S, Kean TJ, Razavi M. An osteogenic magnesium alloy with improved corrosion resistance, antibacterial, and mechanical properties for orthopedic applications. J Biomed Mater Res A 2023; 111:556-574. [PMID: 36494895 DOI: 10.1002/jbm.a.37476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 07/08/2022] [Accepted: 11/28/2022] [Indexed: 12/14/2022]
Abstract
The aim of this study was to develop a novel biodegradable magnesium (Mg) alloy for bone implant applications. We used scandium (Sc; 2 wt %) and strontium (Sr; 2 wt %) as alloying elements due to their high biocompatibility, antibacterial efficacy, osteogenesis, and protective effects against corrosion. In the present work, we also examined the effect of a heat treatment process on the properties of the Mg-Sc-Sr alloy. Alloys were manufactured using a metal casting process followed by heat treatment. The microstructure, corrosion, mechanical properties, antibacterial activity, and osteogenic activity of the alloy were assessed in vitro. The results showed that the incorporation of Sc and Sr elements controlled the corrosion, reduced the hydrogen generation, and enhanced mechanical properties. Furthermore, alloying with Sc and Sr demonstrated a significantly enhanced antibacterial activity and decreased biofilm formation compared to control Mg. Also, culturing Mg-Sc-Sr alloy with human bone marrow-derived mesenchymal stromal cells showed a high degree of biocompatibility (>90% live cells) and a significant increase in osteoblastic differentiation in vitro shown by Alizarin red staining and alkaline phosphatase activity. Based on these results, the Mg-Sc-Sr alloy heat-treated at 400°C displayed optimal mechanical properties, corrosion rate, antibacterial efficacy, and osteoinductivity. These characteristics make the Mg-Sc-Sr alloy a promising candidate for biodegradable orthopedic implants in the fixation of bone fractures such as bone plate-screws or intramedullary nails.
Collapse
Affiliation(s)
- Nadia Aboutalebianaraki
- Biionix™ (Bionic Materials, Implants & Interfaces) Cluster, Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, Florida, USA.,Department of Materials Science and Engineering, University of Central Florida, Orlando, Florida, USA
| | - Peter Zeblisky
- Biionix™ (Bionic Materials, Implants & Interfaces) Cluster, Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, Florida, USA
| | - M D Sarker
- Biionix™ (Bionic Materials, Implants & Interfaces) Cluster, Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, Florida, USA
| | - Aadithya Jeyaranjan
- Department of Materials Science and Engineering, University of Central Florida, Orlando, Florida, USA.,Advanced Materials Processing and Analysis Center, Nanoscience Technology Center, University of Central Florida, Orlando, Florida, USA
| | - Tamil S Sakthivel
- Department of Materials Science and Engineering, University of Central Florida, Orlando, Florida, USA.,Advanced Materials Processing and Analysis Center, Nanoscience Technology Center, University of Central Florida, Orlando, Florida, USA
| | - Yifei Fu
- Department of Materials Science and Engineering, University of Central Florida, Orlando, Florida, USA.,Advanced Materials Processing and Analysis Center, Nanoscience Technology Center, University of Central Florida, Orlando, Florida, USA
| | - John Lucchi
- Department of Chemistry, University of Central Florida, Orlando, Florida, USA.,National Center for Forensic Science, University of Central Florida, Orlando, Florida, USA
| | - Matthieu Baudelet
- Department of Chemistry, University of Central Florida, Orlando, Florida, USA.,National Center for Forensic Science, University of Central Florida, Orlando, Florida, USA.,CREOL - The College of Optics and Photonics, University of Central Florida, Orlando, Florida, USA
| | - Sudipta Seal
- Biionix™ (Bionic Materials, Implants & Interfaces) Cluster, Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, Florida, USA.,Department of Materials Science and Engineering, University of Central Florida, Orlando, Florida, USA.,Advanced Materials Processing and Analysis Center, Nanoscience Technology Center, University of Central Florida, Orlando, Florida, USA
| | - Thomas J Kean
- Biionix™ (Bionic Materials, Implants & Interfaces) Cluster, Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, Florida, USA
| | - Mehdi Razavi
- Biionix™ (Bionic Materials, Implants & Interfaces) Cluster, Department of Internal Medicine, College of Medicine, University of Central Florida, Orlando, Florida, USA.,Department of Materials Science and Engineering, University of Central Florida, Orlando, Florida, USA
| |
Collapse
|
14
|
Shi L, Chen S, Zheng F, Mingming L, Yang H, Zhang B. Corrosion resistance evaluation of biodegradable magnesium alloy vascular stents optimized by mechanical adapted polymer coating strategy. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.130664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
15
|
Bioabsorbable, elastomer-coated magnesium alloy coils for treating saccular cerebrovascular aneurysms. Biomaterials 2022; 290:121857. [DOI: 10.1016/j.biomaterials.2022.121857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 10/06/2022] [Accepted: 10/09/2022] [Indexed: 11/19/2022]
|
16
|
Xing Y, Liang G, Zhu T. Current status and outlook of potential applications of biodegradable materials in cerebral vascular stents. Neurosurg Rev 2022; 45:3565-3571. [PMID: 36214907 DOI: 10.1007/s10143-022-01876-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Revised: 09/02/2022] [Accepted: 09/24/2022] [Indexed: 10/17/2022]
Abstract
The treatment of intracranial aneurysms (IAs) has undergone a very significant transformation in recent decades, and endovascular interventions have gradually become one of the most common treatments. As permanent metal stents can cause some degree of long-term damage to patients, biodegradable stent materials are emerging as attractive potential alternatives. By reviewing the current research status and the advantages and disadvantages of existing biodegradable biomaterials, this review expects to provide a valuable reference for subsequent research on biodegradable biomaterials.
Collapse
Affiliation(s)
- Yiqi Xing
- Dalian Medical University, Graduate School, 9 West section of Lushun South Road, Dalian, 116044, China
- General Hospital of Northern Theater Command, Institute of Neuroscience, Shenyang, Liaoning, China
| | - Guobiao Liang
- General Hospital of Northern Theater Command, Institute of Neuroscience, Shenyang, Liaoning, China
| | - Tingzhun Zhu
- General Hospital of Northern Theater Command, Institute of Neuroscience, Shenyang, Liaoning, China.
| |
Collapse
|
17
|
Sreenivasamurthy SA, Akhter FF, Akhter A, Su Y, Zhu D. Cellular mechanisms of biodegradable zinc and magnesium materials on promoting angiogenesis. BIOMATERIALS ADVANCES 2022; 139:213023. [PMID: 35882117 DOI: 10.1016/j.bioadv.2022.213023] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 06/15/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
Abstract
Biodegradable metals, zinc and magnesium, have been regarded as next-generation, biomedical implant materials to promote tissue repair and regeneration. These implants might also promote the vascularization of surrounding neotissue. Released metallic ions, Zn2+ and Mg2+, show promise in vitro to implement vessel growth by stimulating the expression of pro-angiogenic cytokines, yet there is little known regarding how cellular responses transcend to influence the tissue environment. This study serves to optimize angiogenic behavior using EA.hy926 endothelial cultures exposed to Zn2+ and Mg2+ gradients and observe the translation of these effects on blood vessel development via the in ovo chorioallantoic membrane (CAM) assay. Findings indicate that Zn2+ 10 μM and Mg2+ 10 mM instigate the most prominent effects using endothelial cultures via scratch wound and tube formation assays, yet higher concentrations at Zn2+ 50 μM and Mg2+ 50 mM encourage significant angiogenesis along the CAM. Immunoblotting results also conclude the presence and upregulation of cytokines involved in vessel growth. Optimizing the angiogenic potential of Zn2+ and Mg2+ separately sheds light to design future engineering constructs for promoting blood vessel development and successful assimilation between host and implant tissue.
Collapse
Affiliation(s)
- Sai A Sreenivasamurthy
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States
| | - Fnu Firoz Akhter
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States
| | - Asma Akhter
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States
| | - Yingchao Su
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States
| | - Donghui Zhu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11790, United States.
| |
Collapse
|
18
|
Cho DH, Avey T, Nam KH, Dean D, Luo AA. In vitro and in vivo assessment of squeeze-cast Mg-Zn-Ca-Mn alloys for biomedical applications. Acta Biomater 2022; 150:442-455. [DOI: 10.1016/j.actbio.2022.07.040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Revised: 07/20/2022] [Accepted: 07/25/2022] [Indexed: 11/30/2022]
|
19
|
Current Status and Outlook of Temporary Implants (Magnesium/Zinc) in Cardiovascular Applications. METALS 2022. [DOI: 10.3390/met12060999] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Medical application materials must meet multiple requirements, and the designed material must mimic the structure, shape. and support the formation of the replacing tissue. Magnesium (Mg) and Zinc alloys (Zn), as a “smart” biodegradable material and as “the green engineering material in the 21st century”, have become an outstanding implant material due to their natural degradability, smart biocompatibility, and desirable mechanical properties. Magnesium and Zinc are recognized as the next generation of cardiovascular stents and bioresorbable scaffolds. At the same time, improving the properties and corrosion resistance of these alloys is an urgent challenge. particularly to promote the application of magnesium alloys. A relatively fast deterioration rate of magnesium-based materials generally results in premature mechanical integrity compromise and local hydrogen build-up, resulting in restricted applicability. This review article aims to give a comprehensive comparison between Zn-based alloys and Mg-based alloys, focusing primarily on degradation and biocompatibility for cardiovascular applications. The recent clinical trials using these biodegradable metals have also been addressed.
Collapse
|
20
|
Dargusch MS, Balasubramani N, Yang N, Johnston S, Ali Y, Wang G, Venezuela J, Carluccio J, Lau C, Allavena R, Liang D, Mardon K, Ye Q. In vivo performance of a rare earth free Mg–Zn–Ca alloy manufactured using twin roll casting for potential applications in the cranial and maxillofacial fixation devices. Bioact Mater 2022; 12:85-96. [PMID: 35087965 PMCID: PMC8777300 DOI: 10.1016/j.bioactmat.2021.10.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/24/2021] [Accepted: 10/18/2021] [Indexed: 12/20/2022] Open
Abstract
A magnesium alloy containing essential, non-toxic, biodegradable elements such as Ca and Zn has been fabricated using a novel twin-roll casting process (TRC). Microstructure, mechanical properties, in vivo corrosion and biocompatibility have been assessed and compared to the properties of the rare earth (RE) element containing WE43 alloy. TRC Mg-0.5 wt% Zn- 0.5 wt% Ca exhibited fine grains with an average grain size ranging from 70 to 150 μm. Mechanical properties of a TRC Mg-0.5Zn-0.5Ca alloy showed an ultimate tensile strength of 220 MPa and ductility of 9.3%. The TRC Mg-0.5Zn-0.5Ca alloy showed a degradation rate of 0.51 ± 0.07 mm/y similar to that of the WE43 alloy (0.47 ± 0.09 mm/y) in the rat model after 1 week of implantation. By week 4 the biodegradation rates of both alloys studied were lowered and stabilized with fewer gas pockets around the implant. The histological analysis shows that both WE43 and TRC Mg-0.5Zn-0.5Ca alloy triggered comparable tissue healing responses at respective times of implantation. The presence of more organized scarring tissue around the TRC Mg-0.5Zn-0.5Ca alloys suggests that the biodegradation of the RE-free alloy may be more conducive to the tissue proliferation and remodelling process. Mg-0.5Zn-0.5Ca alloy plates were fabricated by a twin-roll casting (TRC) process. TRC alloy showed an ultimate strength and elongation of 221 ± 2 MPa and 9 ± 2%. Gas development during in vivo degradation was analysed using μ-CT techniques. Histological analysis revealed a good biocompatibility and promoted healing.
Collapse
|
21
|
de Andrade LM, Paternoster C, Chevallier P, Gambaro S, Mengucci P, Mantovani D. Surface processing for iron-based degradable alloys: A preliminary study on the importance of acid pickling. Bioact Mater 2022; 11:166-180. [PMID: 34938921 PMCID: PMC8665346 DOI: 10.1016/j.bioactmat.2021.09.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 09/04/2021] [Accepted: 09/20/2021] [Indexed: 01/01/2023] Open
Abstract
The formation of a heterogeneous oxidized layer, also called scale, on metallic surfaces is widely recognized as a rapid manufacturing event for metals and their alloys. Partial or total removal of the scale represents a mandatory integrated step for the industrial fabrication processes of medical devices. For biodegradable metals, acid pickling has already been reported as a preliminary surface preparation given further processes, such as electropolishing. Unfortunately, biodegradable medical prototypes presented discrepancies concerning acid pickling studies based on samples with less complex geometry (e.g., non-uniform scale removal and rougher surface). Indeed, this translational knowledge lacks a detailed investigation on this process, deep characterization of treated surfaces properties, as well as a comprehensive discussion of the involved mechanisms. In this study, the effects of different acidic media (HCl, HNO3, H3PO4, CH3COOH, H2SO4 and HF), maintained at different temperatures (21 and 60 °C) for various exposition time (15-240 s), on the chemical composition and surface properties of a Fe-13Mn-1.2C biodegradable alloy were investigated. Changes in mass loss, morphology and wettability evidenced the combined effect of temperature and time for all conditions. Pickling in HCl and HF solutions favor mass loss (0.03-0.1 g/cm2) and effectively remove the initial scale.
Collapse
Affiliation(s)
- Letícia Marin de Andrade
- Laboratory for Biomaterials and Bioengineering, Canada Research Chair I in Biomaterials and Bioengineering for the Innovation in Surgery, Department of Min-Met-Materials Engineering, Research Center of CHU de Quebec, Division of Regenerative Medicine, Laval University, Quebec City, QC, G1V 0A6, Canada
| | - Carlo Paternoster
- Laboratory for Biomaterials and Bioengineering, Canada Research Chair I in Biomaterials and Bioengineering for the Innovation in Surgery, Department of Min-Met-Materials Engineering, Research Center of CHU de Quebec, Division of Regenerative Medicine, Laval University, Quebec City, QC, G1V 0A6, Canada
| | - Pascale Chevallier
- Laboratory for Biomaterials and Bioengineering, Canada Research Chair I in Biomaterials and Bioengineering for the Innovation in Surgery, Department of Min-Met-Materials Engineering, Research Center of CHU de Quebec, Division of Regenerative Medicine, Laval University, Quebec City, QC, G1V 0A6, Canada
| | - Sofia Gambaro
- Laboratory for Biomaterials and Bioengineering, Canada Research Chair I in Biomaterials and Bioengineering for the Innovation in Surgery, Department of Min-Met-Materials Engineering, Research Center of CHU de Quebec, Division of Regenerative Medicine, Laval University, Quebec City, QC, G1V 0A6, Canada
- National Research Council, Institute of Condensed Matter Chemistry and Technologies for Energy CNR-ICMATE, Genoa, 16149, Italy
| | | | - Diego Mantovani
- Laboratory for Biomaterials and Bioengineering, Canada Research Chair I in Biomaterials and Bioengineering for the Innovation in Surgery, Department of Min-Met-Materials Engineering, Research Center of CHU de Quebec, Division of Regenerative Medicine, Laval University, Quebec City, QC, G1V 0A6, Canada
| |
Collapse
|
22
|
Li Y, Wang Y, Shen Z, Miao F, Wang J, Sun Y, Zhu S, Zheng Y, Guan S. A biodegradable magnesium alloy vascular stent structure: Design, optimisation and evaluation. Acta Biomater 2022; 142:402-412. [PMID: 35085798 DOI: 10.1016/j.actbio.2022.01.045] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 01/05/2022] [Accepted: 01/18/2022] [Indexed: 02/07/2023]
Abstract
The existing biodegradable magnesium alloy stent (BMgS) structure is prone to problems, such as insufficient support capacity and early fracture at areas of concentrated stress. Herein, a stent structural design, which reduced the cross section of the traditional sin-wave stent by nearly 30% and introduces a regular arc structure in the middle of the support ring. The influence of the dual-parameter design of bending radius (r) and ring length (L) on plastic deformation, expansion and compression resistance performances are discussed. The non-dominated sorting genetic algorithm II (NSGA-II) was used to search for the optimal solution. It was found that the introduction of parameter r effectively improved the plastic deformation and expansion performance, and the reduction of L improved stent compression resistance. Finally, an optimized stent configuration was obtained. In vitro mechanical tests, including balloon inflation, radial strength and flexibility, verified the simulation results. The radial strength for the optimised stent increases by approximately 40% compared with that for the sinusoidal stent. Microarea X-ray diffraction result shows that the circumferential residual stress for the optimised stent decreases by half compared with that for the sinusoidal stent, thus effectively reducing the stress concentration phenomenon. STATEMENT OF SIGNIFICANCE: Despite current progress in BMgS research, the optimal design of the structure is limited. We present a new type of structurally designed stent. The performance of this stent was analysed by a finite element method and experimentally verified. The structural design positively influenced stent performance.
Collapse
Affiliation(s)
- Yafei Li
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China
| | - Yan Wang
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China
| | - Zhenquan Shen
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Fulong Miao
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China
| | - Jianfeng Wang
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China
| | - Yufeng Sun
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China
| | - Shijie Zhu
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China
| | - Yufeng Zheng
- School of Materials Science and Engineering, College of Engineering, Peking University, Beijing 100871, China
| | - Shaokang Guan
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China.
| |
Collapse
|
23
|
Yu H, Hou Z, Chen N, Luo R, Yang L, Miao M, Ma X, Zhou L, He F, Shen Y, Liu X, Wang Y. Yes-associated Protein Contributes to Magnesium Alloy-derived Inflammation in Endothelial Cells. Regen Biomater 2022; 9:rbac002. [PMID: 35480861 PMCID: PMC9039498 DOI: 10.1093/rb/rbac002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 12/25/2021] [Accepted: 01/04/2022] [Indexed: 11/19/2022] Open
Abstract
Magnesium alloy (Mg alloy) has attracted massive attention in the potential applications of cardiovascular stents because of its good biocompatibility and degradability. However, whether and how the Mg alloy induces inflammation in endothelial cells remains unclear. In the present work, we investigated the activation of Yes-associated protein (YAP) upon Mg alloy stimuli and unveiled the transcriptional function in Mg alloy-induced inflammation. Quantitative RT–PCR, western blotting and immunofluorescence staining showed that Mg alloy inhibited the Hippo pathway to facilitate nuclear shuttling and activation of YAP in human coronary artery endothelial cells (HCAECs). Chromatin immunoprecipitation followed sequencing was carried out to explore the transcriptional function of YAP in Mg alloy-derived inflammation. This led to the observation that nuclear YAP further bonded to the promoter region of inflammation transcription factors and co-transcription factors. This binding event activated their transcription and modified mRNA methylation of inflammation-related genes through regulating the expression of N6-methyladenosine modulators (METTL3, METTL14, FTO and WTAP). This then promoted inflammation-related gene expression and aggravated inflammation in HCAECs. In YAP deficiency cells, Mg alloy-induced inflammation was reduced. Collectively, our data suggest that YAP contributes to the Mg alloy-derived inflammation in HCAECs and may provide a potential therapeutic target that alleviates inflammation after Mg alloy stent implantation.
Collapse
Affiliation(s)
- Hongchi Yu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
- Institute of Biomedical Engineering, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China
| | - Zhe Hou
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| | - Nuoya Chen
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| | - Rifang Luo
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| | - Li Yang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| | - Michael Miao
- Division of Oral & Craniofacial Health Sciences, University of North Carolina Adams School of Dentistry, Chapel Hill, NC,27599, USA
| | - Xiaoyi Ma
- Beijing Key Laboratory of Cardiac Drug Device Technology and Evidence Based Medicine, Beijing 100021, China
| | - Lifeng Zhou
- Beijing Key Laboratory of Cardiac Drug Device Technology and Evidence Based Medicine, Beijing 100021, China
| | - Fugui He
- Beijing Key Laboratory of Cardiac Drug Device Technology and Evidence Based Medicine, Beijing 100021, China
| | - Yang Shen
- Institute of Biomedical Engineering, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China
| | - Xiaoheng Liu
- Institute of Biomedical Engineering, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| |
Collapse
|
24
|
Current status and outlook of biodegradable metals in neuroscience and their potential applications as cerebral vascular stent materials. Bioact Mater 2021; 11:140-153. [PMID: 34938919 PMCID: PMC8665265 DOI: 10.1016/j.bioactmat.2021.09.025] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Revised: 09/01/2021] [Accepted: 09/18/2021] [Indexed: 12/12/2022] Open
Abstract
Over the past two decades, biodegradable metals (BMs) have emerged as promising materials to fabricate temporary biomedical devices, with the purpose of avoiding potential side effects of permanent implants. In this review, we first surveyed the current status of BMs in neuroscience, and briefly summarized the representative stents for treating vascular stenosis. Then, inspired by the convincing clinical evidence on the in vivo safety of Mg alloys as cardiovascular stents, we analyzed the possibility of producing biodegradable cerebrovascular Mg alloy stents for treating ischemic stroke. For these novel applications, some key factors should also be considered in designing BM brain stents, including the anatomic features of the cerebral vasculature, hemodynamic influences, neuro-cytocompatibility and selection of alloying elements. This work may provide insights into the future design and fabrication of BM neurological devices, especially for brain stents. The current status of the application of biodegradable metals (BM) in neuroscience was presented. We analyzed the possibility of producing biodegradable cerebrovascular Mg alloy stents for ischemic stroke treatment. Key factors in designing BM brain stents were discussed. This work may provide insights into the future design and fabrication of BM neurological devices, especially for brain stents.
Collapse
|
25
|
Fallesen CO, Antonsen L, Maehara A, Noori M, Hougaard M, Hansen KN, Ellert J, Ahlehoff O, Veien KT, Lassen JF, Junker AB, Hansen HS, Jensen LO. Optical coherence tomography versus angiography guided magnesium bioresorbable scaffold implantation in NSTEMI patients. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2021; 40:101-110. [PMID: 34949544 DOI: 10.1016/j.carrev.2021.12.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 11/30/2021] [Accepted: 12/06/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND The purpose of a bioresorbable scaffold (BRS) is to provide radial support during coronary healing. In this study, coronary artery healing after optical coherence tomography (OCT)- versus angiography-guided magnesium BRS (MBRS) implantation in patients with non-ST-segment-elevation myocardial infarction (NSTEMI) is compared. METHODS 75 patients were randomized 1:1 to OCT- or angiography-guided implantation of a MBRS with protocolled pre- and post-dilation. In the OCT-guided group, prespecified criteria indicating additional intervention were (1) scaffold under-expansion, (2) strut malapposition, (3) edge dissection, and (4) residual stenosis at distal or proximal reference segments. The primary endpoint was OCT-derived healing stage at 6 months. RESULTS At 6 months, there was no difference in average healing stage between OCT- and angiography-guided intervention (4.6 [interquartile range (IQR): 4.5-4.7] versus 4.5 [IQR: 4.3-4.7]; p = 0.54). The MBRSs were completely resolved in 77.0% [IQR: 68.5-85.5] versus 76.5% [IQR: 67.9-85.5]; (p = 0.97). Minimal lumen area (MLA) was reduced at 6 months in both the OCT- (32.3%; p < 0.01) and the angiography-guided group (21.3%; p < 0.01), however OCT-guided implantation was associated with a greater reduction of total lumen volume (-27.1 ± 32.5 mm3 versus -5.0 ± 32.9 mm3; p < 0.01) and MLA (-2.3 ± 1.6 mm2 vs. -1.4 ± 1.4 mm2; p = 0.02). CONCLUSIONS In NSTEMI patients, OCT-guidance with protocolled pre- and post-dilation of MBRS implantation showed similar healing pattern at 6 months compared to angiography-guidance alone. CLINICAL TRIAL REGISTRATION The Coronary Artery Healing Process after Optical Coherence Tomography Guided Percutaneous Coronary Intervention with Magmaris Bioresorbable Scaffold in Patients with Non-ST-Segment-Elevation Myocardial Infarction: (HONEST) trial is registered with ClinicalTrials.gov, NCT03016624.
Collapse
Affiliation(s)
| | - Lisbeth Antonsen
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | - Akiko Maehara
- Cardiovascular Research Foundation, NY Presbyterian Hospital, New York, USA
| | - Manijeh Noori
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | - Mikkel Hougaard
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | - Julia Ellert
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | - Ole Ahlehoff
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | | | - Anders Bo Junker
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | | |
Collapse
|
26
|
Dong J, Pacella M, Liu Y, Zhao L. Surface engineering and the application of laser-based processes to stents - A review of the latest development. Bioact Mater 2021; 10:159-184. [PMID: 34901537 PMCID: PMC8636930 DOI: 10.1016/j.bioactmat.2021.08.023] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 08/04/2021] [Accepted: 08/20/2021] [Indexed: 12/21/2022] Open
Abstract
Late in-stent thrombus and restenosis still represent two major challenges in stents’ design. Surface treatment of stent is attracting attention due to the increasing importance of stenting intervention for coronary artery diseases. Several surface engineering techniques have been utilised to improve the biological response in vivo on a wide range of biomedical devices. As a tailorable, precise, and ultra-fast process, laser surface engineering offers the potential to treat stent materials and fabricate various 3D textures, including grooves, pillars, nanowires, porous and freeform structures, while also modifying surface chemistry through nitridation, oxidation and coatings. Laser-based processes can reduce the biodegradable materials' degradation rate, offering many advantages to improve stents’ performance, such as increased endothelialisation rate, prohibition of SMC proliferation, reduced platelet adhesion and controlled corrosion and degradation. Nowadays, adequate research has been conducted on laser surface texturing and surface chemistry modification. Laser texturing on commercial stents has been also investigated and a promotion of performance of laser-textured stents has been proved. In this critical review, the influence of surface texture and surface chemistry on stents performance is firstly reviewed to understand the surface characteristics of stents required to facilitate cellular response. This is followed by the explicit illustration of laser surface engineering of stents and/or related materials. Laser induced periodic surface structure (LIPSS) on stent materials is then explored, and finally the application of laser surface modification techniques on latest generation of stent devices is highlighted to provide future trends and research direction on laser surface engineering of stents. Compared conventional surface engineering with laser-based methods for biomedical devices. Explained the influence of texture geometry and surface chemistry on stents biological response. Reviewed state of the art in laser surface engineering of stents for improved biological response. Reviewed state of the art in laser surface engineering to control degradation of bioresorbable stents. Highlighted novel laser surface engineering designs for improved stents'performance.
Collapse
Affiliation(s)
- J Dong
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU, UK
| | - M Pacella
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU, UK
| | - Y Liu
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU, UK.,Centre for Biological Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU, UK
| | - L Zhao
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU, UK
| |
Collapse
|
27
|
Zhang ZQ, Yang YX, Li JA, Zeng RC, Guan SK. Advances in coatings on magnesium alloys for cardiovascular stents - A review. Bioact Mater 2021; 6:4729-4757. [PMID: 34136723 PMCID: PMC8166647 DOI: 10.1016/j.bioactmat.2021.04.044] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/27/2021] [Accepted: 04/27/2021] [Indexed: 12/15/2022] Open
Abstract
Magnesium (Mg) and its alloys, as potential biodegradable materials, have drawn wide attention in the cardiovascular stent field because of their appropriate mechanical properties and biocompatibility. Nevertheless, the occurrence of thrombosis, inflammation, and restenosis of implanted Mg alloy stents caused by their poor corrosion resistance and insufficient endothelialization restrains their anticipated clinical applications. Numerous surface treatment tactics have mainly striven to modify the Mg alloy for inhibiting its degradation rate and enduing it with biological functionality. This review focuses on highlighting and summarizing the latest research progress in functionalized coatings on Mg alloys for cardiovascular stents over the last decade, regarding preparation strategies for metal oxide, metal hydroxide, inorganic nonmetallic, polymer, and their composite coatings; and the performance of these strategies in regulating degradation behavior and biofunction. Potential research direction is also concisely discussed to help guide biological functionalized strategies and inspire further innovations. It is hoped that this review can give assistance to the surface modification of cardiovascular Mg-based stents and promote future advancements in this emerging research field.
Collapse
Affiliation(s)
- Zhao-Qi Zhang
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou, 450001, PR China
| | - Yong-Xin Yang
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou, 450001, PR China
| | - Jing-An Li
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou, 450001, PR China
| | - Rong-Chang Zeng
- Corrosion Laboratory for Light Metals, College of Material Science and Engineering, Shandong University of Science and Technology, Qingdao, 266590, China
| | - Shao-Kang Guan
- School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, 100 Science Road, Zhengzhou, 450001, PR China
| |
Collapse
|
28
|
Lu Y, Deshmukh S, Jones I, Chiu YL. Biodegradable magnesium alloys for orthopaedic applications. BIOMATERIALS TRANSLATIONAL 2021; 2:214-235. [PMID: 35836650 PMCID: PMC9255811 DOI: 10.12336/biomatertransl.2021.03.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 07/14/2021] [Accepted: 08/16/2021] [Indexed: 12/04/2022]
Abstract
There is increasing interest in the development of bone repair materials for biomedical applications. Magnesium (Mg)-based alloys have a natural ability to biodegrade because they corrode in aqueous media; they are thus promising materials for orthopaedic device applications in that the need for a secondary surgical operation to remove the implant can be eliminated. Notably, Mg has superior biocompatibility because Mg is found in the human body in abundance. Moreover, Mg alloys have a low elastic modulus, close to that of natural bone, which limits stress shielding. However, there are still some challenges for Mg-based fracture fixation. The degradation of Mg alloys in biological fluids can be too rapid, resulting in a loss of mechanical integrity before complete healing of the bone fracture. In order to achieve an appropriate combination of bio-corrosion and mechanical performance, the microstructure needs to be tailored properly by appropriate alloy design, as well as the use of strengthening processes and manufacturing techniques. This review covers the evolution, current strategies and future perspectives of Mg-based orthopaedic implants.
Collapse
Affiliation(s)
- Yu Lu
- School of Metallurgy and Materials, University of Birmingham, Birmingham, UK
| | - Subodh Deshmukh
- Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK
| | - Ian Jones
- School of Metallurgy and Materials, University of Birmingham, Birmingham, UK
| | - Yu-Lung Chiu
- School of Metallurgy and Materials, University of Birmingham, Birmingham, UK,Corresponding author: Yu-Lung Chiu,
| |
Collapse
|
29
|
Recent advances in cardiovascular stent for treatment of in-stent restenosis: Mechanisms and strategies. Chin J Chem Eng 2021. [DOI: 10.1016/j.cjche.2020.11.025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
30
|
Li W, Su Y, Ma L, Zhu S, Zheng Y, Guan S. Sol-gel coating loaded with inhibitor on ZE21B Mg alloy for improving corrosion resistance and endothelialization aiming at potential cardiovascular application. Colloids Surf B Biointerfaces 2021; 207:111993. [PMID: 34364249 DOI: 10.1016/j.colsurfb.2021.111993] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 07/05/2021] [Accepted: 07/16/2021] [Indexed: 12/31/2022]
Abstract
To improve the service performance of vascular stents, we designed/selected a series of organic compounds from commercial drugs, natural plants, and marine life as the potential corrosion inhibitors for ZE21B alloy. Paeonol condensation tyrosine (PCTyr) Schiff base was found to be the most efficient inhibitor among them. The biocompatible, self-healing, anti-corrosive sol-gel coating loaded with corrosion inhibitor was fabricated on the Mg substrate through a convenient dip-coating tactic. The corrosion resistance, self-healing ability, cytotoxicity, and hemocompatibility of the coated sample were evaluated. These results suggested the potentiality of Schiff base inhibitor-loaded sol-gel coating for enhanced corrosion protection and desired biocompatibility of bioabsorbable cardiovascular implants.
Collapse
Affiliation(s)
- Weijie Li
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China
| | - Ya Su
- Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China
| | - Liang Ma
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China
| | - Shijie Zhu
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China
| | - Yufeng Zheng
- College of Engineering, State Key Laboratory for Turbulence and Complex System, Department of Materials Science and Engineering, Peking University, Beijing 100871, China
| | - Shaokang Guan
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Magnesium Alloys, Zhengzhou 450002, China; Key Laboratory of Advanced Materials Processing & Mold Ministry of Education, Zhengzhou 450002, China.
| |
Collapse
|
31
|
Hassan HW, Grasso V, Korostynska O, Khan H, Jose J, Mirtaheri P. An overview of assessment tools for determination of biological Magnesium implant degradation. Med Eng Phys 2021; 93:49-58. [PMID: 34154775 DOI: 10.1016/j.medengphy.2021.05.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 04/22/2021] [Accepted: 05/19/2021] [Indexed: 12/14/2022]
Abstract
Medical implants made of biodegradable materials are advantageous for short-term applications as fracture fixation and mechanical support during bone healing. After completing the healing process, the implant biodegrades without any long-term side effects nor any need for surgical removal. In particular, Magnesium (Mg) implants, while degrading, can cause physiological changes in the tissues surrounding the implant. The evaluation of structural remodeling is relevant, however, the functional assessment is crucial to provide information about physiological changes in tissues, which can be applied as an early marker during the healing process. Hence, non-invasive monitoring of structural and functional changes in the surrounding tissue during the healing process is essential, and the need for new assessing methods is emerging. This paper provides an assessment of Mg based implants, and an extensive review of the literature is presented with the focus on the imaging techniques for investigation of the Mg implants' biodegradation. The potential of a hybrid analysis, including Near-Infrared Spectroscopy (NIRS) and photoacoustic imaging (PAI) technology, is further discussed. A hybrid solution may play a significant role in monitoring implants and have several advantages for monitoring tissue oxygenation in addition to tissue's acidity, which is directly connected to the Mg implants degradation process. Such a hybrid assessment system can be a simple, ambulant, and less costly technology with the potential for clinically monitoring of Mg implants at site.
Collapse
Affiliation(s)
- Hafiz Wajahat Hassan
- Oslo Metropolitan University, Faculty of Technology, Art and Design, Department of Mechanical, Electronic and Chemical Engineering, Oslo, Norway
| | | | - Olga Korostynska
- Oslo Metropolitan University, Faculty of Technology, Art and Design, Department of Mechanical, Electronic and Chemical Engineering, Oslo, Norway
| | - Haroon Khan
- Oslo Metropolitan University, Faculty of Technology, Art and Design, Department of Mechanical, Electronic and Chemical Engineering, Oslo, Norway
| | - Jithin Jose
- FUJIFILM VisualSonics, Amsterdam, The Netherlands
| | - Peyman Mirtaheri
- Oslo Metropolitan University, Faculty of Technology, Art and Design, Department of Mechanical, Electronic and Chemical Engineering, Oslo, Norway.
| |
Collapse
|
32
|
Park S, Lee H, Kim HE, Jung HD, Jang TS. Bifunctional poly (l-lactic acid)/hydrophobic silica nanocomposite layer coated on magnesium stents for enhancing corrosion resistance and endothelial cell responses. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 127:112239. [PMID: 34225879 DOI: 10.1016/j.msec.2021.112239] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 05/25/2021] [Accepted: 06/02/2021] [Indexed: 11/28/2022]
Abstract
Biodegradable magnesium (Mg)-based vascular stents can overcome the limitations of conventional permanent metallic stents, such as late in-stent restenosis and thrombosis, but still have difficulty retarding degradation while providing adequate mechanical support to the blood vessel. We incorporated silica nanoparticles surface-functionalized with hexadecyltrimethoxysilane (mSiNP) into a poly (l-lactic acid) (PLLA) coating as a physical barrier to disturb the penetration of the corrosive medium as well as a bioactive source that releases silicon ions capable of stimulating endothelial cells. The corrosion resistance and biocompatibility of this bifunctional PLLA/mSiNP nanocomposite coating were investigated using different weight ratios of mSiNP. The nanocomposite coating containing more than 10 wt% of the mSiNP (PLLA/10mSiNP and PLLA/20mSiNP) significantly delayed the corrosion of the Mg substrate and exhibited favorable endothelial cell responses, compared to the pure PLLA coating. Specifically, the calculated corrosion rates of PLLA/10mSiNP and PLLA/20mSiNP decreased by half, indicating the durability of the coating after immersion in simulated body fluid for 12 days. Based on the in vitro cellular response, the incorporation of the mSiNPs into the PLLA coating significantly improved the endothelial cell responses to the Mg substrate, showing better initial cell surface coverage, migration, and proliferation rate than those of pure PLLA. These results indicate that the PLLA/mSiNP nanocomposite coatings have significant potential to improve the corrosion resistance and vascular compatibility of biodegradable Mg-based vascular stents.
Collapse
Affiliation(s)
- Suhyung Park
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea
| | - Hyun Lee
- Department of Biomedical-Chemical Engineering, Catholic University of Korea, Bucheon, Republic of Korea; Department of Biotechnology, The Catholic University of Korea, Bucheon 14662, Republic of Korea
| | - Hyoun-Ee Kim
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea; Biomedical Implant Convergence Research lab, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| | - Hyun-Do Jung
- Department of Biomedical-Chemical Engineering, Catholic University of Korea, Bucheon, Republic of Korea; Department of Biotechnology, The Catholic University of Korea, Bucheon 14662, Republic of Korea.
| | - Tae-Sik Jang
- Department of Materials Science and Engineering, Chosun University, Gwangju, Republic of Korea.
| |
Collapse
|
33
|
Amukarimi S, Mozafari M. Biodegradable magnesium-based biomaterials: An overview of challenges and opportunities. MedComm (Beijing) 2021; 2:123-144. [PMID: 34766139 PMCID: PMC8491235 DOI: 10.1002/mco2.59] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 01/10/2021] [Accepted: 01/14/2021] [Indexed: 12/26/2022] Open
Abstract
As promising biodegradable materials with nontoxic degradation products, magnesium (Mg) and its alloys have received more and more attention in the biomedical field very recently. Having excellent biocompatibility and unique mechanical properties, magnesium-based alloys currently cover a broad range of applications in the biomedical field. The use of Mg-based biomedical devices eliminates the need for biomaterial removal surgery after the healing process and reduces adverse effects induced by the implantation of permanent biomaterials. However, the high corrosion rate of Mg-based implants leads to unexpected degradation, structural failure, hydrogen evolution, alkalization, and cytotoxicity. To overcome these limitations, alloying Mg with suitable alloying elements and surface treatment come highly recommended. In this area, open questions remain on the behavior of Mg-based biomaterials in the human body and the effects of different factors that have resulted in these challenges. In addition to that, many techniques are yet to be verified to turn these challenges into opportunities. Accordingly, this article aims to review major challenges and opportunities for Mg-based biomaterials to minimize the challenges for the development of novel biomaterials made of Mg and its alloys.
Collapse
Affiliation(s)
- Shukufe Amukarimi
- Department of Tissue Engineering & Regenerative Medicine, Faculty of Advanced Technologies in MedicineIran University of Medical Sciences (IUMS)TehranIran
| | - Masoud Mozafari
- Department of Tissue Engineering & Regenerative Medicine, Faculty of Advanced Technologies in MedicineIran University of Medical Sciences (IUMS)TehranIran
| |
Collapse
|
34
|
Hou Z, Xiang M, Chen N, Cai X, Zhang B, Luo R, Yang L, Ma X, Zhou L, He F, Yu H, Wang Y. The biological responses and mechanisms of endothelial cells to magnesium alloy. Regen Biomater 2021; 8:rbab017. [PMID: 34211729 PMCID: PMC8240605 DOI: 10.1093/rb/rbab017] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 03/22/2021] [Accepted: 04/05/2021] [Indexed: 12/03/2022] Open
Abstract
Due to its good biocompatibility and degradability, magnesium alloy (Mg alloy) has shown great promise in cardiovascular stent applications. Rapid stent re-endothelialization is derived from migrated and adhered endothelial cells (ECs), which is an effective way to reduce late thrombosis and inhibit hyperplasia. However, fundamental questions regarding Mg alloy affecting migration and adhesion of ECs are not fully understood. Here, we evaluated the effects of Mg alloy on the ECs proliferation, adhesion and migration. A global gene expression profiling of ECs co-culturing with Mg alloy was conducted, and the adhesion- and migration-related genes were examined. We found that Mg alloy had no adverse effects on ECs viability but significantly affected ECs migration and adhesion. Co-cultured with Mg alloy extract, ECs showed contractive adhesion morphology and decreased motility, which was supported by the down-regulation of adhesion-related genes (Paxillin and Vinculin) and migration-related genes (RAC 1, Rho A and CDC 42). Accordingly, the re-endothelialization of Mg alloy stent was inhibited in vivo. Our results may provide new inspiration for improving the broad application of Mg alloy stents.
Collapse
Affiliation(s)
- Zhe Hou
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Maolong Xiang
- College of Life Sciences, Sichuan University, Chengdu 610064, China
| | - Nuoya Chen
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Xiao Cai
- The Fourth People's Hospital of Chengdu, Chengdu 610036, China
| | - Bo Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Rifang Luo
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Li Yang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| | - Xiaoyi Ma
- Beijing Key Laboratory of Cardiac Drug Device Technology and Evidence Based Medicine, Beijing 100021, China
| | - Lifeng Zhou
- Beijing Key Laboratory of Cardiac Drug Device Technology and Evidence Based Medicine, Beijing 100021, China
| | - Fugui He
- Beijing Key Laboratory of Cardiac Drug Device Technology and Evidence Based Medicine, Beijing 100021, China
| | - Hongchi Yu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
- Institute of Biomedical Engineering, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China
| |
Collapse
|
35
|
Controlled biodegradation of magnesium alloy in physiological environment by metal organic framework nanocomposite coatings. Sci Rep 2021; 11:8645. [PMID: 33883594 PMCID: PMC8060305 DOI: 10.1038/s41598-021-87783-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 04/05/2021] [Indexed: 11/17/2022] Open
Abstract
Magnesium-based implants (MBIs) have recently attracted great attention in bone regeneration due to elastic modulus similar to bone. Nevertheless, the degradation rate and hydrogen release of MBIs in the body have to be tackled for practical applications. In the present study, we present a metal–organic framework (MOF) nanoplates to reduce the degradation rate of AZ91 magnesium alloy. Zeolitic imidazolate frameworks (ZIF-8) with a specific surface area of 1789 m2 g−1 were prepared by solvothermal methods, and after dispersion in a chitosan solution (10% w/w), the suspension was electrospun on the surface of AZ91 alloy. Studying the degradation rate in simulated body fluid (SBF) by electrochemical analysis including potentiodynamic polarization and electrochemical impedance spectroscopy reveals that the degradation rate of the surface-modified implants decreases by ~ 80% as compared with the unmodified specimens. The reduced alkalization of the physiological environment and hydrogen release due to the implant degradation are shown. In vitro studies by fibroblasts and MG63 osteosarcoma cells exhibit improved cell adhesion and viability. The mechanisms behind the improved degradation resistance and enhanced bioactivity are presented and discussed. Surface modification of MBIs by MOF-chitosan coatings is a promising strategy to control the biodegradation of magnesium implants for bone regeneration.
Collapse
|
36
|
Odashima K, Shimizu Y, Sano Y, Yamamoto A, Mukai T, Takada Y, Yanagisawa Y, Imai Y, Takahashi T, Kumamoto H. Osteogenic response under the periosteum by magnesium implantation in rat tibia. Dent Mater J 2021; 40:498-507. [PMID: 33642444 DOI: 10.4012/dmj.2020-011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study was designed to examine osteoconductive effects of Mg in rats tibia. The animals were sacrificed after 1, 2, and 8 weeks. The elemental analysis was performed using SEM/EDX at week 1. Following X-ray micrography at weeks 2 and 8, samples were embedded in paraffin. The expression of osteocalcin was observed by immunohistochemical staining. The element concentrations of fibrous capsules around the specimens were also measured by ICP-MS. The concentrations of Ca and P on the surface of the Mg specimen increased in SEM/EDX. The tissue specimen showed new bone formation on the bone surface near the implanted area. The concentrations of Mg, Ca, and P were high in the fibrous capsules surrounding Mg. Implantation induced differentiation of osteoblasts, and this process was considered to be associated with new bone formation. Induction of cell differentiation may be influenced by corrosion products in addition to corroding magnesium.
Collapse
Affiliation(s)
- Kenji Odashima
- Division of Oral and Maxillofacial Surgery, Department of Oral and Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Yoshinaka Shimizu
- Division of Oral Pathology, Department of Oral Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Yuya Sano
- Division of Oral Pathology, Department of Oral Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Akiko Yamamoto
- Biometals Group, Biomaterials Unit, Nano-life Field, International Center for Materials Nanoarchitectonics, National Institute for Materials Science
| | - Toshiji Mukai
- Department of Mechanical Engineering, Kobe University
| | - Yukyo Takada
- Division of Dental Biomaterials, Tohoku University Graduate School of Dentistry, Tohoku University
| | - Yuta Yanagisawa
- Division of Oral and Maxillofacial Surgery, Department of Oral and Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Yoshimichi Imai
- Department of Plastic and Reconstructive Surgery, Tohoku University Graduate School of Medicine
| | - Tetsu Takahashi
- Division of Oral and Maxillofacial Surgery, Department of Oral and Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| | - Hiroyuki Kumamoto
- Division of Oral Pathology, Department of Oral Medicine and Surgery, Graduate School of Dentistry, Tohoku University
| |
Collapse
|
37
|
Guo L, Yu L, Zhao Q, Gong X, Xie H, Yuan G, Li B, Wan X. Biodegradable JDBM coating stent has potential to be used in the treatment of benign biliary strictures. Biomed Mater 2021; 16:025010. [PMID: 33429375 DOI: 10.1088/1748-605x/abda88] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
In our previous study, to find out the optimal alloy suitable for biliary surgery, magnesium alloy Jiao Da Bio-magnesium (denoted as JDBM) alloy, Zn-3Cu alloys, and their respective coating (MgF2-PDLLA) products were produced for our research. We found that JDBM seems to be a potential material for clinical biliary stent application due to its uniform degradation and good compatibility. In order to apply the JDBM alloy to treat benign bile duct stricture, our group prepared the bare JDBM and its coating product into finished stents by mesh weaving carving technology and conducted the mechanical property tests, degradation tests and biocompatibility tests. During the mechanical property tests, we found the bare JDBM stent was more suitable than titanium alloy stent when applies to the bile duct, and the coating of the JDBM coating stent has no effect on its mechanical properties. Our in vitro and in vivo experiments revealed that the degradation rate of the JDBM coating stent is lower than that of the JDBM stent, and both stents were biosafe. Thus, there is promise for JDBM coating stents for the treatment of benign biliary strictures.
Collapse
Affiliation(s)
- Lili Guo
- Shanghai Key Laboratory of Pancreatic Diseases, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 201620, People's Republic of China. Department of Gastroenterology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, New Songjiang Road No. 650, Shanghai 201620, People's Republic of China
| | | | | | | | | | | | | | | |
Collapse
|
38
|
Fallesen CO, Maehara A, Antonsen L, Nørregaard Hansen K, Noori M, Flensted Lassen J, Junker A, Hansen HS, Okkels Jensen L. Coronary Artery Healing Process after Bioresorbable Scaffold in Patients with Non-ST-Segment Elevation Myocardial Infarction: Rationale, Design, and Methodology of the HONEST Study. Cardiology 2021; 146:161-171. [PMID: 33524985 DOI: 10.1159/000512417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 09/30/2020] [Indexed: 11/19/2022]
Abstract
BACKGROUND Bioresorbable scaffolds (BRSs) is a relatively new approach in treating coronary artery stenosis. The initial results of the first commercially available scaffolds consisting of a backbone of poly-L-lactide raised safety concerns related to delayed resorption and healing. The magnesium alloy-based scaffold degrades via bio-corrosion within months, whereas it often takes several years for polymer scaffolds to degrade. The aim of the study was to assess the healing stage by optical coherence tomography (OCT) after 6 months in patients with non-ST-segment elevation myocardial infarct (NSTEMI) randomized to OCT or angiography-guided percutaneous coronary intervention with implantation of a magnesium sirolimus-eluting Magmaris scaffold (Magmaris; Biotronik, Bülach, Switzerland). METHODS We analyzed the healing process by comparing OCT at baseline and after 6 months. Five stages of healing were defined with stage 1 being the least healed and stage 5 demonstrating complete resorption and healing with no visible scaffold/remnant. The primary end point is a calculated healing score that is based on 5 subtypes of healing stage: (1) malapposed, (2) uncovered with no detection of smooth surface tissue on top of struts or remnants, (3) covered protruding, (4) covered embedded, and (5) complete healing with a smooth neointimal surface and no sign of struts or visible remnants assessed by OCT 6 months after the index procedure. RESULTS The impact of OCT-guided compared to angiography-guided scaffold implantation will be illuminated. CONCLUSION The present study will provide new information on midterm healing properties of the magnesium BRS in patients with NSTEMI.
Collapse
Affiliation(s)
| | - Akiko Maehara
- Cardiovascular Research Foundation, New York Presbyterian Hospital, New York, New York, USA
| | - Lisbeth Antonsen
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | - Manijeh Noori
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | - Anders Junker
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | | |
Collapse
|
39
|
Magnetron sputtered magnesium-based thin film metallic glasses for bioimplants. Biointerphases 2021; 16:011005. [PMID: 33706531 DOI: 10.1116/6.0000535] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Mg-based thin film metallic glasses (TFMGs) can viably decrease stress shielding caused by mismatch of the modulus of elasticity between the implant material and human bone. Here, Mg-based TFMGs were fabricated onto implantable substrates by ion assisted pulsed DC magnetron sputtering. The microstructure assessment and the impact of the principle constituents of the coatings were determined utilizing an x-ray diffractometer, a transmission electron microscope, and x-ray photoelectron spectroscopy. The hardness of these thin films was estimated to be 5.1 GPa. In vitro degradation tests including electrochemical studies and immersion tests in simulated body fluid revealed that the presence of zinc could raise the corrosion resistance of Mg-based TFMG. Indirect in vitro cytotoxicity using L929 fibroblast cells revealed that the TFMGs did not induce any toxicity in cells. Biomineralization experiments using Saos-2 cells promoted the formation of calcium phosphate on its surface.
Collapse
|
40
|
Thermo-Fluid-Dynamic Modeling of the Melt Pool during Selective Laser Melting for AZ91D Magnesium Alloy. MATERIALS 2020; 13:ma13184157. [PMID: 32962085 PMCID: PMC7560334 DOI: 10.3390/ma13184157] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 09/09/2020] [Accepted: 09/15/2020] [Indexed: 11/17/2022]
Abstract
A three dimensional finite element model (FEM) was established to simulate the temperature distribution, flow activity, and deformation of the melt pool of selective laser melting (SLM) AZ91D magnesium alloy powder. The latent heat in phase transition, Marangoni effect, and the movement of laser beam power with a Gaussian energy distribution were taken into account. The influence of the applied linear laser power on temperature distribution, flow field, and the melt-pool dimensions and shape, as well as resultant densification activity, was investigated and is discussed in this paper. Large temperature gradients and high cooling rates were observed during the process. A violent flow occurred in the melt pool, and the divergent flow makes the melt pool wider and longer but shallower. With the increase of laser power, the melt pool’s size increases, but the shape becomes longer and narrower. The width of the melt pool in single-scan experiment is acquired, which is in good agreement with the results predicted by the simulation (with error of 1.49%). This FE model provides an intuitive understanding of the complex physical phenomena that occur during SLM process of AZ91D magnesium alloy. It can help to select the optimal parameters to improve the quality of final parts and reduce the cost of experimental research.
Collapse
|
41
|
Controlling the dissolution of iron through the development of nanostructured Fe-Mg for biomedical applications. Acta Biomater 2020; 113:660-676. [PMID: 32553917 DOI: 10.1016/j.actbio.2020.06.014] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 06/05/2020] [Accepted: 06/09/2020] [Indexed: 01/25/2023]
Abstract
In the field of biodegradable metallic materials, rapid and non-uniform biodegradation, caused by uncontrolled corrosion rates, is a potential shortcoming. Among the prominent biodegradable materials, magnesium is an attractive choice, however, it is prone to rapid dissolution. In contrast, iron possesses a slow dissolution rate. To approach the middle ground, instead of making magnesium more corrosion-resistant, the less-explored approach of making iron less corrosion-resistant is employed here. In this study, iron, and magnesium, having contrasting corrosion rates, are combined via magnetron co-sputtering. The idea of combinatorial synthesis is employed to fabricate two model nanostructured Fe-Mg samples, i.e. CSFM-1 (Fe85Mg15), and CSFM-2 (Fe65Mg35), exhibiting a controlled and uniform degradation in phosphate-buffer saline solution. The structural characterization of the two samples demonstrates a substitutional solid solution of bcc-Fe-Mg in CSFM-1 and an amorphous short-range-ordered structure in the CSFM-2 sample. Electrochemical investigation shows increased corrosion rates for the two Fe-Mg samples in comparison to pure Fe, validated by relatively active corrosion potentials, higher corrosion current densities, faster anodic dissolution, and lower charge transfer resistances, governed by chemical composition and non-equilibrium nanostructures. Finally, nano-indentation testing of the two samples reveals relatively higher hardness and lower elastic moduli, a suitable combination for bio-implants. STATEMENT OF SIGNIFICANCE: The use of Mg as a biodegradable in-vivo implant material is problematic because of its high dissolution rate and potential for hydrogen gas generation. This is the first time that the idea of combinatorial synthesis is employed to fabricate two model nanostructured Fe-Mg systems, i.e. CSFM-1 (Fe85Mg15), and CSFM-2 (Fe65Mg35), exhibiting a controlled and uniform degradation. The structural characterization of the two systems demonstrates a substitutional solid solution of bcc-Fe-Mg in CSFM-1 and an amorphous short-range-ordered structure in the CSFM-2 system. Electrochemical investigation shows increased biodegradation rates for the two Fe-Mg systems in comparison to pure Fe, validated by relatively active corrosion potentials, higher corrosion current densities, faster anodic dissolution, and lower charge transfer resistances, governed by chemical composition and non-equilibrium nanostructures.
Collapse
|
42
|
Li P, Li X, Cai W, Chen H, Chen H, Wang R, Zhao Y, Wang J, Huang N. Phospholipid-based multifunctional coating via layer-by-layer self-assembly for biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 116:111237. [PMID: 32806322 DOI: 10.1016/j.msec.2020.111237] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 05/29/2020] [Accepted: 06/23/2020] [Indexed: 11/28/2022]
Abstract
As an important class of biomaterials,bionics inspired materials has been widely used in creating extracorporeal and implantable medical devices. However, specific service environment is often faced with multiple requirements rather than single function. Herein, we designed a phospholipid-based multifunctional coating with phospholipids-based polymers, type I collagen (Col-I) and Arg-Glu-Asp-Val (REDV) peptide, via layer-by-layer assembly. The successful synthesis of the polymers and the coating is proved by a series of characterization methods including Fourier transforming infrared spectra (FTIR), proton nuclear magnetic resonance (1H NMR), ultraviolet-visible spectra (UV) and X-ray photoelectron spectroscopy (XPS), while the assembly process and quality change of the coating were monitored via quartz crystal microbalance (QCM). Besides, hydrophilicity and roughness of this coating was analyzed via water contact angle (WCA) and atomic force microscope (AFM), respectively. Finally, results from platelet adhesion, activation assay, smooth muscle cells (SMCs) and endothelial cells (ECs) cultures indicated that the multifunctional coating could strongly inhibit platelet adhesion and SMCs proliferation, hence provide practical application of the coating with good biocompatibility, especially the anticoagulant property and cell compatibility. It is expected that this coating may be used in blood-contacting fields such as cardiovascular stent or other devices in the future.
Collapse
Affiliation(s)
- Peichuang Li
- Key Lab. of Advanced Technology for Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Xiaojing Li
- Key Lab. of Advanced Technology for Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Wanhao Cai
- Institute of Physical Chemistry, Albert-Ludwigs-Universität Freiburg, Albertstraße 23a, 79104 Freiburg, Germany
| | - Huiqing Chen
- Key Lab. of Advanced Technology for Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Hang Chen
- Key Lab. of Advanced Technology for Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Rui Wang
- Key Lab. of Advanced Technology for Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Yuancong Zhao
- Key Lab. of Advanced Technology for Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
| | - Jin Wang
- Key Lab. of Advanced Technology for Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
| | - Nan Huang
- Key Lab. of Advanced Technology for Materials of Education Ministry, Southwest Jiaotong University, Chengdu 610031, China; School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| |
Collapse
|
43
|
Jin L, Chen C, Jia G, Li Y, Zhang J, Huang H, Kang B, Yuan G, Zeng H, Chen T. The bioeffects of degradable products derived from a biodegradable Mg-based alloy in macrophages via heterophagy. Acta Biomater 2020; 106:428-438. [PMID: 32044459 DOI: 10.1016/j.actbio.2020.02.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 01/30/2020] [Accepted: 02/04/2020] [Indexed: 01/09/2023]
Abstract
Biodegradable magnesium alloys are promising candidates for use in biomedical applications. However, degradable particles (DPs) derived from Mg-based alloys have been observed in tissue in proximity to sites of implantation, which might result in unexpected effects. Although previous in vitro studies have found that macrophages can take up DPs, little is known about the potential phagocytic pathway and the mechanism that processes DPs in cells. Additionally, it is necessary to estimate the potential bioeffects of DPs on macrophages. Thus, in this study, DPs were generated from a Mg-2.1Nd-0.2Zn-0.5Zr alloy (JDBM) by an electrochemical method, and then macrophages were incubated with the DPs to reveal the potential impact. The results showed that the cell viability of macrophages decreased in a concentration-dependent manner in the presence of DPs due to effects of an apoptotic pathway. However, the DPs were phagocytosed into the cytoplasm of macrophages and further degraded in phagolysosomes, which comprised lysosomes and phagosomes, by heterophagy instead of autophagy. Furthermore, several pro-inflammatory cytokines in macrophages were upregulated by DPs through the induction of reactive oxygen species (ROS) production. To the best of our knowledge, this is the first study to show that DPs derived from a Mg-based alloy are consistently degraded in phagolysosomes after phagocytosis by macrophages via heterophagy, which results in an inflammatory response owing to ROS overproduction. Thus, our research has increased the knowledge of the metabolism of biodegradable Mg metal, which will contribute to an understanding of the health effects of biodegradable magnesium metal implants used for tissue repair. STATEMENT OF SIGNIFICANCE: Biomedical degradable Mg-based alloys have great promise in applied medicine. Although previous studies have found that macrophages can uptake degradable particles (DPs) in vitro and observed in the sites of implantation in vivoin vivo, few studies have been carried out on the potential bioeffects relationship between DPs and macrophages. In this study, we analyzed the bioeffects of DPs derived from a Mg-based alloy on the macrophages. We illustrated that the DPs were size-dependently engulfed by macrophages via heterophagy and further degraded in the phagolysosome rather than autophagosome. Furthermore, DPs were able to induce a slight inflammatory response in macrophages by inducing ROS production. Thus, our research enhances the knowledge of the interaction between DPs of Mg-based alloy and cells, and offers a new perspective regarding the use of biodegradable alloys.
Collapse
|
44
|
The Functional Properties of Mg-Zn-X Biodegradable Magnesium Alloys. MATERIALS 2020; 13:ma13030544. [PMID: 31979227 PMCID: PMC7040658 DOI: 10.3390/ma13030544] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2019] [Revised: 01/17/2020] [Accepted: 01/20/2020] [Indexed: 11/17/2022]
Abstract
The implantation of metallic devices in orthopaedic surgical procedures and coronary angioplasty is associated with the risk of various adverse events: (i) mechanical (premature failure), (ii) chemo-mechanical (corrosion and corrosion-fatigue degradation) and (iii) biomedical (chronic local inflammatory reactions, tissue necrosis, etc.). In this regard, the development of biodegradable implants/stents, which provide the necessary mechanical support for the healing period of the bone or the vessel wall and then are completely resorbed, has bright prospects. Magnesium alloys are the most suitable candidates for that purpose due to their superior mechanical performance, bioresorbability and biocompatibility. This article presents the results of the comparative research on several wrought biodegradable alloys, assessing their potential for biomedical applications. The Mg-Zn-X alloys with different chemical compositions and microstructures were produced using severe plastic deformation techniques. Functional properties pivotal for biomedical applications-mechanical strength, in vitro corrosion resistance and cytotoxic activity-were included in the focus of the study. Excellent mechanical performance and low cytotoxic effects are documented for all alloys with a notable exception for one of two Mg-Zn-Zr alloys. The in vitro corrosion resistance is, however, below expectations due to critical impurities, and this property has yet to be drastically improved through the cleaner materials fabrication processing before they can be considered for biomedical applications.
Collapse
|
45
|
Chalisgaonkar R. Insight in applications, manufacturing and corrosion behaviour of magnesium and its alloys – A review. ACTA ACUST UNITED AC 2020. [DOI: 10.1016/j.matpr.2020.02.211] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
46
|
Khan MM, Rahman ZU, Deen KM, Shabib I, Haider W. Sputtered Mg100-xZnx (0 ≤ x ≤ 100) systems as anode materials for a biodegradable battery aimed for transient bioelectronics. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2019.135129] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
47
|
Adhikari U, An X, Rijal N, Hopkins T, Khanal S, Chavez T, Tatu R, Sankar J, Little KJ, Hom DB, Bhattarai N, Pixley SK. Embedding magnesium metallic particles in polycaprolactone nanofiber mesh improves applicability for biomedical applications. Acta Biomater 2019; 98:215-234. [PMID: 31059833 DOI: 10.1016/j.actbio.2019.04.061] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 04/28/2019] [Accepted: 04/30/2019] [Indexed: 12/19/2022]
Abstract
Magnesium (Mg) metal is of great interest in biomedical applications, especially in tissue engineering. Mg exhibits excellent in vivo biocompatibility, biodegradability and, during degradation, releases Mg ions (Mg2+) with the potential to improve tissue repair. We used electrospinning technology to incorporate Mg particles into nanofibers. Various ratios of Mg metal microparticles (<44 µm diameter) were incorporated into nanofiber polycaprolactone (PCL) meshes. Physicochemical properties of the meshes were analyzed by scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), mechanical tensile testing, X-ray diffractometry and UV-VIS spectrophotometry. Biological properties of meshes were evaluated in vitro and in vivo. Under mammalian cell culture conditions, Mg-containing meshes released hydrogen gas and relative amounts of free Mg2+ that reflected the Mg/PCL ratios. All meshes were non-cytotoxic for 3T3 fibroblasts and PC-12 pheochromocytoma cells. In vivo implantation under the skin of mice for 3, 8 and 28 days showed that Mg-containing meshes were well vascularized, with improved measures of inflammation and healing compared to meshes without Mg. Evidence included an earlier appearance and infiltration of tissue repairing macrophages and, after 28 days, evidence of more mature tissue remodeling. Thus, these new composite nanofiber meshes have promising material properties that mitigated inflammatory tissue responses to PCL alone and improved tissue healing, thus providing a suitable matrix for use in clinically relevant tissue engineering applications. STATEMENT OF SIGNIFICANCE: The biodegradable metal, magnesium, safely biodegrades in the body, releasing beneficial byproducts. To improve tissue delivery, magnesium metal particles were incorporated into electrospun nanofiber meshes composed of a biodegradable, biocompatible polymer, polycaprolactone (PCL). Magnesium addition, at several concentrations, did not alter PCL chemistry, but did alter physical properties. Under cell culture conditions, meshes released magnesium ions and hydrogen gas and were not cytotoxic for two cell types. After implantation in mice, the mesh with magnesium resulted in earlier appearance of M2-like, reparative macrophages and improved tissue healing versus mesh alone. This is in agreement with other studies showing beneficial effects of magnesium metal and provides a new type of scaffold material that will be useful in clinically relevant tissue engineering applications.
Collapse
|
48
|
Magnesium matrix nanocomposites for orthopedic applications: A review from mechanical, corrosion, and biological perspectives. Acta Biomater 2019; 96:1-19. [PMID: 31181263 DOI: 10.1016/j.actbio.2019.06.007] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 05/28/2019] [Accepted: 06/05/2019] [Indexed: 02/06/2023]
Abstract
Magnesium (Mg) and some of its alloys have attracted extensive interests for biomedical applications as they exhibit biodegradability and low elastic modulus that is closer to natural bones than the currently used metallic implant materials such as titanium (Ti) and its alloys, stainless steels, and cobalt-chromium (Co-Cr) alloys. However, the rapid degradation of Mg alloys and loss of their mechanical integrity before sufficient bone healing impede their clinical application. Our literature review shows that magnesium matrix nanocomposites (MMNCs) reinforced with nanoparticles possess enhanced strength, high corrosion resistance, and good biocompatibility. This article provides a detailed analysis of the effects of nanoparticle reinforcements on the mechanical properties, corrosion behavior, and biocompatibility of MMNCs as promising biodegradable implant materials. The governing equations to quantitatively predict the mechanical properties and underlying synergistic strengthening mechanisms in MMNCs are elucidated. The potential, recent advances, challenges and future research directions in relation to nanoparticles reinforced MMNCs are highlighted. STATEMENT OF SIGNIFICANCE: Critically reviewing magnesium metal matrix nanocomposites (MMNCs) for the biomedical application. Clear definitions of strengthening mechanisms using reinforcement particle in the magnesium matrix, as there were controversial in governing equations of strengthening parameters. Providing better understanding of the effect of particle size, volume fraction, interfacial bonding, and uniform dispersion of reinforcement particles on MMNCs.
Collapse
|
49
|
Abstract
Absorbable metals have been introduced as materials to fabricate temporary medical implants. Iron, magnesium and zinc have been considered as major base elements of such metals. The metallurgical characterization and in-vitro corrosion assessment of these metals have been covered by the new ASTM standards F3160 and F3268. However, the in-vivo corrosion characterization and assessment of absorbable metal implants are not yet well established. The corrosion of metals in the in-vivo environment leads to metal ion release and corrosion product formation that may cause excessive toxicity. The aim of this work is to introduce the techniques to assess absorbable metal implants and their in-vivo corrosion behavior. This contains the existing approaches, e.g., implant retrieval and histological analysis, ultrasonography and radiography, and the new techniques for real-time in-vivo corrosion monitoring.
Collapse
|
50
|
Xue B, Liang B, Yuan G, Zhu L, Wang H, Lu Z, Xu Z. A pilot study of a novel biodegradable magnesium alloy airway stent in a rabbit model. Int J Pediatr Otorhinolaryngol 2019; 117:88-95. [PMID: 30579096 DOI: 10.1016/j.ijporl.2018.10.047] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 10/30/2018] [Accepted: 10/30/2018] [Indexed: 12/20/2022]
Abstract
OBJECTIVE To preliminarily investigate the feasibility of bioabsorption tracheal stenting for the therapeutic application of congenital tracheal stenosis (CTS). STUDY DESIGN Experimental research. SETTING Shanghai Children Medical Center, National Children's Medical Center. SUBJECTS AND METHODS Five kinds of magnesium alloys with different compositions were studied in this paper, a patented Mg-Nd-Zn-Zr alloy series namely JDBM (JiaoDa BioMg) and four Mg-Ca-Zn alloys. The cytotoxicity of alloys was evaluated by the MTS ([3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium) assay in rabbit tracheal epithelial cells. Specific magnesium alloys had been immersed in the cell culture medium for 24 h. The tracheal stents that were made of magnesium alloy were implanted into the trachea of New Zealand rabbits and the ablation of the stent was monitored by fiber bronchoscopy. The routine blood examination was conducted prior to and following the stent placement. The rabbits were euthanized following 2-3 months of stenting. H&E staining of the main organs was conducted and the induction of apoptosis of the tracheal tissues was monitored. RESULTS The cytotoxicity of the JDBM magnesium alloy was mild and lower than the remaining 4 alloys. The stents were placed successfully in five animals. The tracheal stents were successfully placed and gradually biodegradated as monitored by fiber bronchoscopy; no significant systemic inflammatory response was noted. No significant differences in the liver and/or kidney function prior to and following stent placement were noted. H&E staining indicated the absence of pathological changes in the trachea, liver, heart and/or kidney tissues. The apoptotic assay indicated that the apoptosis ratio of the tracheal tissues was comparable between rabbits with and without tracheal stenting. CONCLUSION The results suggested the feasibility of bioabsorption stents made of biodegradable magnesium alloys using in patients with tracheal stenosis, especially in infants.
Collapse
Affiliation(s)
- Bangde Xue
- Shanghai Children's Medical Center, National Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Department of Cardiovascular Surgery, Shanghai, China; Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Department of Cardiovascular Surgery, Shanghai, China
| | - Beibei Liang
- Shanghai University of Medicine and Health Sciences, Shanghai, China; Biology Research Center, University of Shanghai for Science and Technology, Shanghai, China
| | - Guangyin Yuan
- School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Limin Zhu
- Shanghai Children's Medical Center, National Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Department of Cardiovascular Surgery, Shanghai, China
| | - Hao Wang
- Shanghai Children's Medical Center, National Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Department of Cardiovascular Surgery, Shanghai, China
| | - Zhaohui Lu
- Shanghai Children's Medical Center, National Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Department of Cardiovascular Surgery, Shanghai, China.
| | - Zhiwei Xu
- Shanghai Children's Medical Center, National Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Department of Cardiovascular Surgery, Shanghai, China.
| |
Collapse
|