1
|
Gosset-Erard C, Aubriet F, Leize-Wagner E, François YN, Chaimbault P. Hyphenation of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) with separation methods: The art of compromises and the possible - A review. Talanta 2023; 257:124324. [PMID: 36780779 DOI: 10.1016/j.talanta.2023.124324] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 01/31/2023] [Accepted: 02/02/2023] [Indexed: 02/05/2023]
Abstract
This review provides an overview of the online hyphenation of Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) with separation methods to date. The online coupling between separation techniques (gas and liquid chromatography, capillary electrophoresis) and FT-ICR MS essentially raises questions of compromise and is not look as straightforward as hyphenation with other analyzers (QTOF-MS for instance). FT-ICR MS requires time to reach its highest resolving power and accuracy in mass measurement capabilities whereas chromatographic and electrophoretic peaks are transient. In many applications, the strengths and the weaknesses of each technique are balanced by their hyphenation. Untargeted "Omics" (e.g. proteomics, metabolomics, petroleomics, …) is one of the main areas of application for FT-ICR MS hyphenated to online separation techniques because of the complexity of the sample. FT-ICR MS achieves the required high mass measurement accuracy to determine accurate molecular formulae and resolution for isobar distinction. Meanwhile separation techniques highlight isomers and reduce the ion suppression effects extending the dynamic range. Even if the implementation of FT-ICR MS hyphenated with online separation methods is a little trickier (the art of compromise), this review shows that it provides unparalleled results to the scientific community (the art of the possible), along with raising the issue of its future in the field with the relentless technological progress.
Collapse
Affiliation(s)
- Clarisse Gosset-Erard
- Université de Lorraine, LCP-A2MC, F-57000, Metz, France; Laboratoire de Spectrométrie de Masse des Interactions et des Systèmes (LSMIS) UMR 7140 (Unistra-CNRS), Université de, Strasbourg, France.
| | | | - Emmanuelle Leize-Wagner
- Laboratoire de Spectrométrie de Masse des Interactions et des Systèmes (LSMIS) UMR 7140 (Unistra-CNRS), Université de, Strasbourg, France.
| | - Yannis-Nicolas François
- Laboratoire de Spectrométrie de Masse des Interactions et des Systèmes (LSMIS) UMR 7140 (Unistra-CNRS), Université de, Strasbourg, France.
| | | |
Collapse
|
2
|
Stolz A, Neusüß C. Characterisation of a new online nanoLC-CZE-MS platform and application for the glycosylation profiling of alpha-1-acid glycoprotein. Anal Bioanal Chem 2022; 414:1745-1757. [PMID: 34881393 PMCID: PMC8791864 DOI: 10.1007/s00216-021-03814-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 11/19/2021] [Accepted: 11/30/2021] [Indexed: 11/22/2022]
Abstract
The ever-increasing complexity of biological samples to be analysed by mass spectrometry has led to the necessity of sophisticated separation techniques, including multidimensional separation. Despite a high degree of orthogonality, the coupling of liquid chromatography (LC) and capillary zone electrophoresis (CZE) has not gained notable attention in research. Here, we present a heart-cut nanoLC-CZE-ESI-MS platform to analyse intact proteins. NanoLC and CZE-MS are coupled using a four-port valve with an internal nanoliter loop. NanoLC and CZE-MS conditions were optimised independently to find ideal conditions for the combined setup. The valve setup enables an ideal transfer efficiency between the dimensions while maintaining good separation conditions in both dimensions. Due to the higher loadability, the nanoLC-CZE-MS setup exhibits a 280-fold increased concentration sensitivity compared to CZE-MS. The platform was used to characterise intact human alpha-1-acid glycoprotein (AGP), an extremely heterogeneous N-glycosylated protein. With the nanoLC-CZE-MS approach, 368 glycoforms can be assigned at a concentration of 50 μg/mL as opposed to the assignment of only 186 glycoforms from 1 mg/mL by CZE-MS. Additionally, we demonstrate that glycosylation profiling is accessible for dried blood spot analysis (25 μg/mL AGP spiked), indicating the general applicability of our setup to biological matrices. The combination of high sensitivity and orthogonal selectivity in both dimensions makes the here-presented nanoLC-CZE-MS approach capable of detailed characterisation of intact proteins and their proteoforms from complex biological samples and in physiologically relevant concentrations.
Collapse
Affiliation(s)
- Alexander Stolz
- Faculty of Chemistry, Aalen University, Beethovenstr. 1, 73430, Aalen, Germany
- Department of Pharmaceutical and Medicinal Chemistry, Friedrich Schiller University, 07743, Jena, Germany
| | - Christian Neusüß
- Faculty of Chemistry, Aalen University, Beethovenstr. 1, 73430, Aalen, Germany.
| |
Collapse
|
3
|
Yang Z, Shen X, Chen D, Sun L. Improved Nanoflow RPLC-CZE-MS/MS System with High Peak Capacity and Sensitivity for Nanogram Bottom-up Proteomics. J Proteome Res 2019; 18:4046-4054. [PMID: 31610113 DOI: 10.1021/acs.jproteome.9b00545] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Novel mass spectrometry (MS)-based proteomic tools with extremely high sensitivity and high peak capacity are required for comprehensive characterization of protein molecules in mass-limited samples. We reported a nanoRPLC-CZE-MS/MS system for deep bottom-up proteomics of low micrograms of human cell samples in previous work. In this work, we improved the sensitivity of the nanoRPLC-CZE-MS/MS system drastically via employing bovine serum albumin (BSA)-treated sample vials, improving the nanoRPLC fraction collection procedure, and using a short capillary for fast CZE separation. The improved nanoRPLC-CZE produced a peak capacity of 8500 for peptide separation. The improved system identified 6500 proteins from a MCF7 proteome digest starting with only 500 ng of peptides using a Q-Exactive HF mass spectrometer. The system produced a comparable number of protein identifications (IDs) to our previous system and the two-dimensional (2D) nanoRPLC-MS/MS system developed by Mann's group with 10-fold and 4-fold less sample consumption, respectively. We coupled the single-spot solid phase sample preparation (SP3) method to the improved nanoRPLC-CZE-MS/MS for bottom-up proteomics of 5000 HEK293T cells, resulting in 3689 protein IDs with the consumption of a peptide amount that corresponded to only roughly 1000 cells.
Collapse
Affiliation(s)
- Zhichang Yang
- Department of Chemistry , Michigan State University , 578 S Shaw Lane , East Lansing , Michigan 48824 , United States
| | - Xiaojing Shen
- Department of Chemistry , Michigan State University , 578 S Shaw Lane , East Lansing , Michigan 48824 , United States
| | - Daoyang Chen
- Department of Chemistry , Michigan State University , 578 S Shaw Lane , East Lansing , Michigan 48824 , United States
| | - Liangliang Sun
- Department of Chemistry , Michigan State University , 578 S Shaw Lane , East Lansing , Michigan 48824 , United States
| |
Collapse
|
4
|
Jooß K, Scholz N, Meixner J, Neusüß C. Heart-cut nano-LC-CZE-MS for the characterization of proteins on the intact level. Electrophoresis 2019; 40:1061-1065. [PMID: 30575976 DOI: 10.1002/elps.201800411] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2018] [Revised: 12/15/2018] [Accepted: 12/17/2018] [Indexed: 11/08/2022]
Abstract
Multidimensional separation techniques play an increasingly important role in separation science, especially for the analysis of complex samples such as proteins. The combination of reversed-phase liquid chromatography in the nanoscale and CZE is especially beneficial due to their nearly orthogonal separation mechanism and well-suited geometries/dimensions. Here, a heart-cut nano-LC-CZE-MS setup was developed utilizing for the first time a mechanical 4-port valve as LC-CE interface. A model protein mixture containing four different protein species was first separated by nano LC followed by a heart-cut transfer of individual LC peaks and subsequent CZE-MS analysis. In the CZE dimension, various glycoforms of one protein species were separated. Improved separation capabilities were achieved compared to the 1D methods, which was exemplarily shown for ribonuclease B and its different glycosylated forms. LODs in the lower μg/mL range were determined, which are considerably lower compared to traditional CZE-MS. In addition, this study represents the first application of an LC-CE-MS system for intact protein analysis. The nano-LC-CZE-MS system is expected to be applicable to various other analytical challenges.
Collapse
Affiliation(s)
- Kevin Jooß
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Research Unit Analytical BioGeoChemistry, Helmholtz Zentrum München, Neuherberg, Germany
| | - Nico Scholz
- Faculty of Chemistry, Aalen University, Aalen, Germany
| | - Jens Meixner
- Faculty of Chemistry, Aalen University, Aalen, Germany
| | | |
Collapse
|
5
|
Beutner A, Herl T, Matysik FM. Selectivity enhancement in capillary electrophoresis by means of two-dimensional separation or dual detection concepts. Anal Chim Acta 2018; 1057:18-35. [PMID: 30832915 DOI: 10.1016/j.aca.2018.11.042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 11/01/2018] [Accepted: 11/19/2018] [Indexed: 12/18/2022]
Abstract
For the identification and quantification of analytes in complex samples, highly selective analytical strategies are required. The selectivity of single separation techniques such as gas chromatography (GC), liquid chromatography (LC), or capillary electrophoresis (CE) with common detection principles can be enhanced by hyphenating orthogonal separation techniques but also by using complementary detection systems. In this review, two-dimensional systems containing CE in at least one dimension are reviewed, namely LC-CE or 2D CE systems. Particular attention is paid to the aspect of selectivity enhancement due to the orthogonality of the different separation mechanisms. As an alternative concept, dual detection approaches are reviewed using the common detectors of CE such as UV/VIS, laser-induced fluorescence, capacitively coupled contactless conductivity (C4D), electrochemical detection, and mass spectrometry. Special emphasis is given to dual detection systems implementing the highly flexible C4D as one detection component. Selectivity enhancement can be achieved in case of complementarity of the different detection techniques.
Collapse
Affiliation(s)
- Andrea Beutner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstrasse 31, 93053, Regensburg, Germany
| | - Thomas Herl
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstrasse 31, 93053, Regensburg, Germany
| | - Frank-Michael Matysik
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitaetsstrasse 31, 93053, Regensburg, Germany.
| |
Collapse
|
6
|
Ranjbar L, Foley JP, Breadmore MC. Multidimensional liquid-phase separations combining both chromatography and electrophoresis – A review. Anal Chim Acta 2017; 950:7-31. [DOI: 10.1016/j.aca.2016.10.025] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Revised: 10/17/2016] [Accepted: 10/20/2016] [Indexed: 01/31/2023]
|
7
|
Česla P, Křenková J. Fraction transfer process in on-line comprehensive two-dimensional liquid-phase separations. J Sep Sci 2016; 40:109-123. [DOI: 10.1002/jssc.201600921] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2016] [Revised: 11/15/2016] [Accepted: 11/20/2016] [Indexed: 01/19/2023]
Affiliation(s)
- Petr Česla
- Faculty of Chemical Technology, Department of Analytical Chemistry; University of Pardubice; Pardubice Czech Republic
| | - Jana Křenková
- Institute of Analytical Chemistry of the CAS; v.v.i.; Brno Czech Republic
| |
Collapse
|
8
|
Kohl FJ, Sánchez-Hernández L, Neusüß C. Capillary electrophoresis in two-dimensional separation systems: Techniques and applications. Electrophoresis 2014; 36:144-58. [DOI: 10.1002/elps.201400368] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Revised: 09/16/2014] [Accepted: 09/17/2014] [Indexed: 12/24/2022]
Affiliation(s)
- Felix J. Kohl
- Department of Chemistry; Aalen University; Aalen Germany
| | | | | |
Collapse
|
9
|
Kler PA, Sydes D, Huhn C. Column–coupling strategies for multidimensional electrophoretic separation techniques. Anal Bioanal Chem 2014; 407:119-38. [DOI: 10.1007/s00216-014-8099-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Revised: 08/06/2014] [Accepted: 08/08/2014] [Indexed: 10/24/2022]
|
10
|
Mellors JS, Black WA, Chambers AG, Starkey JA, Lacher NA, Ramsey JM. Hybrid Capillary/Microfluidic System for Comprehensive Online Liquid Chromatography-Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry. Anal Chem 2013; 85:4100-6. [DOI: 10.1021/ac400205a] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Affiliation(s)
| | | | | | - Jason A. Starkey
- Pfizer Biotherapuetics R&D, Pfizer Inc., Chesterfield, Missouri 63017, United States
| | - Nathan A. Lacher
- Pfizer Biotherapuetics R&D, Pfizer Inc., Chesterfield, Missouri 63017, United States
| | | |
Collapse
|
11
|
Abstract
Microscale 2D separation systems have been implemented in capillaries and microfabricated channels. They offer advantages of faster analysis, higher separation efficiency and less sample consumption than the conventional methods, such as liquid chromatography (LC) in a column and slab gel electrophoresis. In this article, we review their recent advancement, focusing on three types of platforms, including 2D capillary electrophoresis (CE), CE coupling with capillary LC, and microfluidic devices. A variety of CE and LC modes have been employed to construct 2D separation systems via sophistically designed interfaces. Coupling of different separation modes has also been realized in a number of microfluidic devices. These separation systems have been applied for the proteomic analysis of various biological samples, ranging from a single cell to tumor tissues.
Collapse
Affiliation(s)
- Xin Xu
- Interdisciplinary Microsystems Group, Department of Mechanical & Aerospace Engineering, University of Florida, Gainesville, FL 32611-6250, USA
| | - Ke Liu
- Interdisciplinary Microsystems Group, Department of Mechanical & Aerospace Engineering, University of Florida, Gainesville, FL 32611-6250, USA
| | - Z. Hugh Fan
- Interdisciplinary Microsystems Group, Department of Mechanical & Aerospace Engineering, University of Florida, Gainesville, FL 32611-6250, USA
- J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131, USA
| |
Collapse
|
12
|
Lee WH, Wang CW, Her GR. Staggered multistep elution solid-phase extraction capillary electrophoresis/tandem mass spectrometry: a high-throughput approach in protein analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:2124-2130. [PMID: 21710592 DOI: 10.1002/rcm.5091] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
An approach based on staggered multistep elution solid-phase extraction (SPE) capillary electrophoresis/tandem mass spectrometry (CE/MS/MS) was developed in the analysis of digested protein mixtures. On-line coupling of SPE with CE/MS was achieved using a two-leveled two-cross polydimethylsiloxane (PDMS)-based interface. Multistep elution SPE was used prior to CE to provide an additional dimension of separation, thus extending the separation capacity for the peptide mixture analysis. By decreasing in the number of co-eluting peptides, problems stemming from ionization suppression and finite MS/MS duty cycle were reduced. As a result, sequence coverage increased significantly using multistep elution SPE-CE/MS/MS compared to one-step elution SPE-CE/MS/MS in the analysis of a single protein tryptic digest (49% vs. 18%) and a six protein tryptic digest (22-71% vs. 10-44%). A staggered CE method was incorporated to increase the throughput. The electropherograms of consecutive CE runs were partially overlapped by injecting the sample plug at a fixed time interval. With the use of a 5 min injection interval, slightly poor results were obtained in comparison with the sequential CE method while the total analysis time was reduced to 28%.
Collapse
Affiliation(s)
- Wei-Han Lee
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | |
Collapse
|
13
|
Chambers AG, Mellors JS, Henley WH, Ramsey JM. Monolithic integration of two-dimensional liquid chromatography-capillary electrophoresis and electrospray ionization on a microfluidic device. Anal Chem 2011; 83:842-9. [PMID: 21214194 PMCID: PMC3059363 DOI: 10.1021/ac102437z] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A microfluidic device capable of two-dimensional reversed-phase liquid chromatography-capillary electrophoresis with integrated electrospray ionization (LC-CE-ESI) for mass spectrometry (MS)-based proteomic applications is described. Traditional instrumentation was used for the LC sample injection and delivery of the LC mobile phase. The glass microfabricated device incorporated a sample-trapping region and an LC channel packed with reversed-phase particles. Rapid electrokinetic injections of the LC effluent into the CE dimension were performed at a cross-channel intersection. The CE separation channel terminated at a corner of the square device, which functioned as an integrated electrospray tip. In addition to LC-CE-ESI, this device was used for LC-ESI without any instrumental modifications. To evaluate the system, LC-MS and LC-CE-MS analyses of protein digests were performed and compared.
Collapse
MESH Headings
- Animals
- Cattle
- Chromatography, Reverse-Phase/instrumentation
- Chromatography, Reverse-Phase/methods
- Electrophoresis, Capillary/instrumentation
- Electrophoresis, Capillary/methods
- Escherichia coli/chemistry
- Microfluidic Analytical Techniques/instrumentation
- Microfluidic Analytical Techniques/methods
- Microscopy, Electron, Scanning
- Peptide Fragments/analysis
- Serum Albumin, Bovine/analysis
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
Collapse
Affiliation(s)
- Andrew G Chambers
- Department of Chemistry, University of North Carolina, Chapel Hill, North Carolina 27599, USA
| | | | | | | |
Collapse
|
14
|
Skinner CD. A liquid chromatography to capillary array electrophoresis interface for two-dimensional separations. Analyst 2010; 135:358-67. [DOI: 10.1039/b915586d] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Zuberovic A, Wetterhall M, Hanrieder J, Bergquist J. CE MALDI-TOF/TOF MS for multiplexed quantification of proteins in human ventricular cerebrospinal fluid. Electrophoresis 2009; 30:1836-43. [DOI: 10.1002/elps.200800714] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
16
|
Palmblad M, Tiss A, Cramer R. Mass spectrometry in clinical proteomics - from the present to the future. Proteomics Clin Appl 2008; 3:6-17. [DOI: 10.1002/prca.200800090] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2008] [Indexed: 12/15/2022]
|
17
|
Herrero M, Ibañez E, Cifuentes A. Capillary electrophoresis-electrospray-mass spectrometry in peptide analysis and peptidomics. Electrophoresis 2008; 29:2148-60. [DOI: 10.1002/elps.200700404] [Citation(s) in RCA: 107] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
18
|
Gaspar A, Englmann M, Fekete A, Harir M, Schmitt-Kopplin P. Trends in CE-MS 2005–2006. Electrophoresis 2008; 29:66-79. [DOI: 10.1002/elps.200700721] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
19
|
Abstract
The article brings a comprehensive survey of recent developments and applications of high-performance capillary electromigration methods, zone electrophoresis, ITP, IEF, affinity electrophoresis, EKC, and electrochromatography, to analysis, preparation, and physicochemical characterization of peptides. New approaches to the theoretical description and experimental verification of electromigration behavior of peptides and to methodology of their separations, such as sample preparation, adsorption suppression, and detection, are presented. Novel developments in individual CE and CEC modes are shown and several types of their applications to peptide analysis are presented: conventional qualitative and quantitative analysis, purity control, determination in biomatrices, monitoring of chemical and enzymatical reactions and physical changes, amino acid and sequence analysis, and peptide mapping of proteins. Some examples of micropreparative peptide separations are given and capabilities of CE and CEC techniques to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- Václav Kasicka
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Prague, Czech Republic.
| |
Collapse
|
20
|
Kusý P, Klepárník K, Aturki Z, Fanali S, Foret F. Optimization of a pressurized liquid junction nanoelectrospray interface between CE and MS for reliable proteomic analysis. Electrophoresis 2007; 28:1964-9. [PMID: 17486659 DOI: 10.1002/elps.200600640] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A pressurized liquid junction nanoelectrospray interface was designed and optimized for reliable on-line CE-MS coupling. The system was constructed as an integrated device for highly sensitive and selective analyses of proteins and peptides with the separation and spray capillaries fixed in a pressurized spray liquid reservoir equipped with the electrode for connection of the electrospray potential. The electrode chamber on the injection side of the separation capillary and the spray liquid reservoir were pneumatically connected by a Teflon tube filled with pressurized nitrogen. This arrangement provided precisely counterbalanced pressures at the inlet and outlet of the separation capillary. The pressure control system was driven by an electrically operated valve and maintained the optimum flow rate for the electrospray stability. All parts of the interface being in contact with the CEBGE, spray liquid and/or sample were made of glass or Teflon. The use of these materials minimized the electrospray chemical noise often caused by plastic softeners or material degradation. During optimization, the transfer of the separated zones between the separation and electrospray capillaries was monitored by UV absorbance and contactless conductivity detectors placed at the outlet of the separation capillary and inlet of the electrospray tip, respectively. This arrangement allowed independent monitoring of the effects of pressure, CE voltage and geometry of the liquid junction on the spreading and dilution of the separated zones after passage through the interface.
Collapse
Affiliation(s)
- Petr Kusý
- Department of Bioanalytical Instrumentation, Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Brno, Czech Republic
| | | | | | | | | |
Collapse
|
21
|
Fournier ML, Gilmore JM, Martin-Brown SA, Washburn MP. Multidimensional Separations-Based Shotgun Proteomics. Chem Rev 2007; 107:3654-86. [PMID: 17649983 DOI: 10.1021/cr068279a] [Citation(s) in RCA: 171] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
22
|
Pierce KM, Hoggard JC, Mohler RE, Synovec RE. Recent advancements in comprehensive two-dimensional separations with chemometrics. J Chromatogr A 2007; 1184:341-52. [PMID: 17697686 DOI: 10.1016/j.chroma.2007.07.059] [Citation(s) in RCA: 134] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2007] [Revised: 07/17/2007] [Accepted: 07/18/2007] [Indexed: 11/30/2022]
Abstract
Comprehensive two-dimensional (2D) separations provide the analyst with a tremendous amount of complex data. In order to glean useful information from this complex data, advancements in commercially available software that implement chemometrics are currently available and continue to evolve. Future advancements will no doubt involve commercializing (or adapting) specialized, in-house chemometric techniques that are currently found only in the hands of technical experts and researchers in industry, government, and academia. In order to make timely advancements, future commercialization of novel chemometric techniques should involve collaborations among instrument software manufacturers, professional programmers, technical experts, and researchers. During the last decade, this field has seen a steady advancement from single analyte target analysis to comprehensive non-target analysis of entire multidimensional sample profiles (involving sample classification and/or data mining for discovery-based sample comparisons). The advancements in instrumentation and chemometric software tools have a tremendous impact in various applications: fuels, food, environmental, pharmaceuticals, metabolomics, etc. Most of the development has been for software to apply with gas chromatography-based instrumentation, such as comprehensive two-dimensional gas chromatography (GC x GC) and comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GC x GC-TOF-MS). More recently there have been notable advancements in liquid-phase instrumentation as well.
Collapse
Affiliation(s)
- Karisa M Pierce
- Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98195-1700 USA
| | | | | | | |
Collapse
|
23
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2007; 42:407-418. [PMID: 17326037 DOI: 10.1002/jms.1072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
|