1
|
Wu T, Wu Y, Yan J, Zhang J, Wang S. Microfluidic chip as a promising evaluation method in assisted reproduction: A systematic review. Bioeng Transl Med 2024; 9:e10625. [PMID: 38435817 PMCID: PMC10905557 DOI: 10.1002/btm2.10625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 10/26/2023] [Accepted: 11/09/2023] [Indexed: 03/05/2024] Open
Abstract
The aim of assisted reproductive technology (ART) is to select the high-quality sperm, oocytes, and embryos, and finally achieve a successful pregnancy. However, functional evaluation is hindered by intra- and inter-operator variability. Microfluidic chips emerge as the one of the most powerful tools to analyze biological samples for reduced size, precise control, and flexible extension. Herein, a systematic search was conducted in PubMed, Scopus, Web of Science, ScienceDirect, and IEEE Xplore databases until March 2023. We displayed and prospected all detection strategies based on microfluidics in the ART field. After full-text screening, 71 studies were identified as eligible for inclusion. The percentages of human and mouse studies equaled with 31.5%. The prominent country in terms of publication number was the USA (n = 13). Polydimethylsiloxane (n = 49) and soft lithography (n = 28) were the most commonly used material and fabrication method, respectively. All articles were classified into three types: sperm (n = 38), oocytes (n = 20), and embryos (n = 13). The assessment contents included motility, counting, mechanics, permeability, impedance, secretion, oxygen consumption, and metabolism. Collectively, the microfluidic chip technology facilitates more efficient, accurate, and objective evaluation in ART. It can even be combined with artificial intelligence to assist the daily activities of embryologists. More well-designed clinical studies and affordable integrated microfluidic chips are needed to validate the safety, efficacy, and reproducibility. Trial registration: The protocol was registered in the Open Science Frame REGISTRIES (identification: osf.io/6rv4a).
Collapse
Affiliation(s)
- Tong Wu
- National Clinical Research Center for Obstetrical and Gynecological DiseasesTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Key Laboratory of Cancer Invasion and Metastasis, Ministry of EducationTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Department of Obstetrics and GynecologyTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
| | - Yangyang Wu
- College of Animal Science and TechnologySichuan Agricultural UniversityYa'anSichuanChina
| | - Jinfeng Yan
- National Clinical Research Center for Obstetrical and Gynecological DiseasesTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Key Laboratory of Cancer Invasion and Metastasis, Ministry of EducationTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Department of Obstetrics and GynecologyTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- School of Materials Science and EngineeringHuazhong University of Science and TechnologyWuhanChina
| | - Jinjin Zhang
- National Clinical Research Center for Obstetrical and Gynecological DiseasesTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Key Laboratory of Cancer Invasion and Metastasis, Ministry of EducationTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Department of Obstetrics and GynecologyTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
| | - Shixuan Wang
- National Clinical Research Center for Obstetrical and Gynecological DiseasesTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Key Laboratory of Cancer Invasion and Metastasis, Ministry of EducationTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
- Department of Obstetrics and GynecologyTongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhanChina
| |
Collapse
|
2
|
Papkovsky DB, Kerry JP. Oxygen Sensor-Based Respirometry and the Landscape of Microbial Testing Methods as Applicable to Food and Beverage Matrices. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094519. [PMID: 37177723 PMCID: PMC10181535 DOI: 10.3390/s23094519] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/19/2023] [Accepted: 04/27/2023] [Indexed: 05/15/2023]
Abstract
The current status of microbiological testing methods for the determination of viable bacteria in complex sample matrices, such as food samples, is the focus of this review. Established methods for the enumeration of microorganisms, particularly, the 'gold standard' agar plating method for the determination of total aerobic viable counts (TVC), bioluminescent detection of total ATP, selective molecular methods (immunoassays, DNA/RNA amplification, sequencing) and instrumental methods (flow cytometry, Raman spectroscopy, mass spectrometry, calorimetry), are analyzed and compared with emerging oxygen sensor-based respirometry techniques. The basic principles of optical O2 sensing and respirometry and the primary materials, detection modes and assay formats employed are described. The existing platforms for bacterial cell respirometry are then described, and examples of particular assays are provided, including the use of rapid TVC tests of food samples and swabs, the toxicological screening and profiling of cells and antimicrobial sterility testing. Overall, O2 sensor-based respirometry and TVC assays have high application potential in the food industry and related areas. They detect viable bacteria via their growth and respiration; the assay is fast (time to result is 2-8 h and dependent on TVC load), operates with complex samples (crude homogenates of food samples) in a simple mix-and-measure format, has low set-up and instrumentation costs and is inexpensive and portable.
Collapse
Affiliation(s)
- Dmitri B Papkovsky
- School of Biochemistry and Cell Biology, University College Cork, Pharmacy Building, College Road, T12 YT20 Cork, Ireland
| | - Joseph P Kerry
- School of Food and Nutritional Sciences, University College Cork, Microbiology Building, College Road, T12 YT20 Cork, Ireland
| |
Collapse
|
3
|
Palacio-Castañeda V, Velthuijs N, Le Gac S, Verdurmen WPR. Oxygen control: the often overlooked but essential piece to create better in vitro systems. LAB ON A CHIP 2022; 22:1068-1092. [PMID: 35084420 DOI: 10.1039/d1lc00603g] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Variations in oxygen levels play key roles in numerous physiological and pathological processes, but are often not properly controlled in in vitro models, introducing a significant bias in experimental outcomes. Recent developments in microfluidic technology have introduced a paradigm shift by providing new opportunities to better mimic physiological and pathological conditions, which is achieved by both regulating and monitoring oxygen levels at the micrometre scale in miniaturized devices. In this review, we first introduce the nature and relevance of oxygen-dependent pathways in both physiological and pathological contexts. Subsequently, we discuss strategies to control oxygen in microfluidic devices, distinguishing between engineering approaches that operate at the device level during its fabrication and chemical approaches that involve the active perfusion of fluids oxygenated at a precise level or supplemented with oxygen-producing or oxygen-scavenging materials. In addition, we discuss readout approaches for monitoring oxygen levels at the cellular and tissue levels, focusing on electrochemical and optical detection schemes for high-resolution measurements directly on-chip. An overview of different applications in which microfluidic devices have been utilized to answer biological research questions is then provided. In the final section, we provide our vision for further technological refinements of oxygen-controlling devices and discuss how these devices can be employed to generate new fundamental insights regarding key scientific problems that call for emulating oxygen levels as encountered in vivo. We conclude by making the case that ultimately emulating physiological or pathological oxygen levels should become a standard feature in all in vitro cell, tissue, and organ models.
Collapse
Affiliation(s)
- Valentina Palacio-Castañeda
- Department of Biochemistry, Radboud Institute for Molecular Life Sciences (RIMLS), Radboud University Medical Center, Geert Grooteplein 28, 6525 GA Nijmegen, The Netherlands.
| | - Niels Velthuijs
- Department of Biochemistry, Radboud Institute for Molecular Life Sciences (RIMLS), Radboud University Medical Center, Geert Grooteplein 28, 6525 GA Nijmegen, The Netherlands.
| | - Séverine Le Gac
- Applied Microfluidics for BioEngineering Research, MESA+ Institute for Nanotechnology & TechMed Centre, Organ-on-a-chip Centre, University of Twente, Postbus 217, 7500 AE Enschede, The Netherlands.
| | - Wouter P R Verdurmen
- Department of Biochemistry, Radboud Institute for Molecular Life Sciences (RIMLS), Radboud University Medical Center, Geert Grooteplein 28, 6525 GA Nijmegen, The Netherlands.
| |
Collapse
|
4
|
Anagnostopoulou C, Rosas IM, Singh N, Gugnani N, Chockalingham A, Singh K, Desai D, Darbandi M, Manoharan M, Darbandi S, Leonardi Diaz SI, Gupta S, Henkel R, Sallam HN, Boitrelle F, Wirka KA, Agarwal A. Oocyte quality and embryo selection strategies: a review for the embryologists, by the embryologists. Panminerva Med 2022; 64:171-184. [PMID: 35179016 DOI: 10.23736/s0031-0808.22.04680-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
With the advance of assisted reproduction techniques, and the trend towards blastocyst culture and single embryo transfer, gamete and embryo assessment have gained greater importance in ART treatment. Embryo quality depends mainly on gamete quality and culture conditions. Oocyte maturity identification is necessary in order to plan fertilization timing. Mature oocytes at the metaphase II stage show a higher fertilization rate compared to immature oocytes. Morphology assessment is a critical yet challenging task that may serve as a good prognostic tool for future development and implantation potential if done effectively. Various grading systems have been suggested to assess embryos at pronuclear, cleavage, and blastocyst stages. By identifying the embryo with the highest implantation potential, it is possible to reduce the number of embryos transferred without compromising the chances of a successful pregnancy. Apart from the conventional morphology assessment, there are several invasive or non-invasive methods for embryo selection such as preimplantation genetic testing, morphokinetics, proteomics, metabolomics, oxygen consumption, and measurement of oxidative stress in culture medium. Morphokinetics is a method based on time-lapse technology and continuous monitoring of embryos. In this review, we aim to describe and compare the most effective and widely used methods for gamete and embryo assessment as well as embryo selection.
Collapse
Affiliation(s)
| | - Israel M Rosas
- Citmer Reproductive Medicine, IVF LAB, Mexico City, Mexico
| | | | - Nivita Gugnani
- Milann-The Fertility Centre, Delhi, India.,All India Institute of Medical Sciences, Delhi, India
| | | | - Keerti Singh
- Faculty of Medical Sciences, The University of the West Indies, Cave Hill Campus, Barbados
| | - Dimple Desai
- DPU IVF & ENDOSCOPY CENTER, Dr. D. Y. Patil Hospital & Research Centre, Pune, India
| | - Mahsa Darbandi
- Fetal Health Research Center, Hope Generation Foundation, Tehran, Iran.,Gene Therapy and Regenerative Medicine Research Center, Hope Generation Foundation, Tehran, Iran
| | | | - Sara Darbandi
- Fetal Health Research Center, Hope Generation Foundation, Tehran, Iran.,Gene Therapy and Regenerative Medicine Research Center, Hope Generation Foundation, Tehran, Iran
| | | | - Sajal Gupta
- American Center for Reproductive Medicine, Cleveland, OH, USA
| | - Ralf Henkel
- American Center for Reproductive Medicine, Cleveland, OH, USA.,Department of Metabolism, Digestion and Reproduction, Imperial College London, London, UK.,Department of Medical Bioscience, University of the Western Cape, Bellville, South Africa.,Logix X Pharma, Theale, Berkshire, UK
| | - Hassan N Sallam
- Department of Obstetrics and Gynaecology, Alexandria University Faculty of Medicine, Alexandria, Egypt
| | - Florence Boitrelle
- Reproductive Biology, Fertility Preservation, Andrology, CECOS, Poissy Hospital, Poissy, France.,Department of Biology, Reproduction, Epigenetics, Environment and Development, ParisSaclay University, UVSQ, INRAE, BREED, Jouyen-Josas, France
| | - Kelly A Wirka
- Fertility & Endocrinology, Medical Affairs, EMD Serono, USA
| | - Ashok Agarwal
- American Center for Reproductive Medicine, Cleveland, OH, USA -
| |
Collapse
|
5
|
Schneider L, Tripathi A. Progress and Challenges in Laboratory-Based Diagnostic and Screening Approaches for Aneuploidy Detection during Pregnancy. SLAS Technol 2021; 26:425-440. [PMID: 34148381 DOI: 10.1177/24726303211021787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Aneuploidy is caused by problems during cellular division and segregation errors during meiosis that lead to an abnormal number of chromosomes and initiate significant genetic abnormalities during pregnancy or the loss of a fetus due to miscarriage. Screening and diagnostic technologies have been developed to detect this genetic condition and provide parents with critical information about their unborn child. In this review, we highlight the complexities of aneuploidy as a disease as well as multiple technological advancements in testing that help to identify aneuploidy at various time points throughout pregnancy. We focus on aneuploidy diagnosis during preimplantation genetic testing that is performed during in vitro fertilization as well as prenatal screening and diagnosis during pregnancy. This review focuses on DNA-based analysis and laboratory techniques for aneuploidy detection through reviewing molecular- and engineering-based technical advancements. We also present key challenges in aneuploidy detection during pregnancy, including sample collection, mosaic embryos, economic factors, and the social implications of this testing. The goal of this review is to synthesize broad information about aneuploidy screening and diagnostic sample collection and analysis during pregnancy and discuss major challenges the field is still facing despite decades of advancements.
Collapse
Affiliation(s)
- Lindsay Schneider
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, RI, USA
| | - Anubhav Tripathi
- Center for Biomedical Engineering, School of Engineering, Brown University, Providence, RI, USA
| |
Collapse
|
6
|
Sequeira RC, Criswell T, Atala A, Yoo JJ. Microfluidic Systems for Assisted Reproductive Technologies: Advantages and Potential Applications. Tissue Eng Regen Med 2020; 17:787-800. [PMID: 33237567 PMCID: PMC7710813 DOI: 10.1007/s13770-020-00311-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 09/16/2020] [Accepted: 10/16/2020] [Indexed: 12/18/2022] Open
Abstract
Microfluidic technologies have emerged as a powerful tool that can closely replicate the in-vivo physiological conditions of organ systems. Assisted reproductive technology (ART), while being able to achieve successful outcomes, still faces challenges related to technical error, efficiency, cost, and monitoring/assessment. In this review, we provide a brief overview of the uses of microfluidic devices in the culture, maintenance and study of ovarian follicle development for experimental and therapeutic applications. We discuss existing microfluidic platforms for oocyte and sperm selection and maintenance, facilitation of fertilization by in-vitro fertilization/intracytoplastimc sperm injection, and monitoring, selection and maintenance of resulting embryos. Furthermore, we discuss the possibility of future integration of these technologies onto a single platform and the limitations facing the development of these systems. In spite of these challenges, we envision that microfluidic systems will likely evolve and inevitably revolutionize both fundamental, reproductive physiology/toxicology research as well as clinically applicable ART.
Collapse
Affiliation(s)
- Russel C Sequeira
- Wake Forest Institute for Regenerative Medicine, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC, 27157, USA
| | - Tracy Criswell
- Wake Forest Institute for Regenerative Medicine, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC, 27157, USA
| | - Anthony Atala
- Wake Forest Institute for Regenerative Medicine, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC, 27157, USA
| | - James J Yoo
- Wake Forest Institute for Regenerative Medicine, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC, 27157, USA.
| |
Collapse
|
7
|
Microfluidic Devices for Gamete Processing and Analysis, Fertilization and Embryo Culture and Characterization. Bioanalysis 2019. [DOI: 10.1007/978-981-13-6229-3_7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
|
8
|
Smith GD, Takayama S. Application of microfluidic technologies to human assisted reproduction. Mol Hum Reprod 2017; 23:257-268. [PMID: 28130394 DOI: 10.1093/molehr/gaw076] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Accepted: 01/11/2017] [Indexed: 12/11/2022] Open
Abstract
Microfluidics can be considered both a science and a technology. It is defined as the study of fluid behavior at a sub-microliter level and the investigation into its application to cell biology, chemistry, genetics, molecular biology and medicine. There are at least two characteristics of microfluidics, mechanical and biochemical, which can be influential in the field of mammalian gamete and preimplantation embryo biology. These microfluidic characteristics can assist in basic biological studies on sperm, oocyte and preimplantation embryo structure, function and environment. The mechanical and biochemical characteristics of microfluidics may also have practical and/or technical application(s) to assisted reproductive technologies (ART) in rodents, domestic species, endangered species and humans. This review will consider data in mammals, and when available humans, addressing the potential application(s) of microfluidics to assisted reproduction. There are numerous sequential steps in the clinical assisted reproductive laboratory process that work, yet could be improved. Cause and effect relations of procedural inefficiencies can be difficult to identify and/or remedy. Data will be presented that consider microfluidic applications to sperm isolation, oocyte cumulus complex isolation, oocyte denuding, oocyte mechanical manipulation, conventional insemination, intracytoplasmic sperm injection, embryo culture, embryo analysis and oocyte and embryo cryopreservation. While these studies have progressed in animal models, data with human gametes and embryos are significantly lacking. These data from clinical trials are requisite for making future evidence-based decisions regarding the application of microfluidics in human ART.
Collapse
Affiliation(s)
- Gary D Smith
- Departments of Obstetrics and Gynecology, Physiology and Urology, University of Michigan, 6428 Medical Sciences I, 1301 E Catherine Street, Ann Arbor, MI 48108-1649, USA
| | - Shuichi Takayama
- Departments of Biomedical Engineering and Macromolecular Science and Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
9
|
Le Gac S, Nordhoff V. Microfluidics for mammalian embryo culture and selection: where do we stand now? Mol Hum Reprod 2016; 23:213-226. [DOI: 10.1093/molehr/gaw061] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Accepted: 09/02/2016] [Indexed: 12/26/2022] Open
|
10
|
Swain JE, Lai D, Takayama S, Smith GD. Thinking big by thinking small: application of microfluidic technology to improve ART. LAB ON A CHIP 2013; 13:1213-24. [PMID: 23400523 DOI: 10.1039/c3lc41290c] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
In Vitro Fertilization (IVF) laboratories often carry a penchant to resist change while in the pursuit of maintaining consistency in laboratory conditions. However, implementation of new technology is often critical to expand scientific discoveries and to improve upon prior successes to advance the field. Microfluidic platforms represent a technology that has the potential to revolutionize the fundamental processes of IVF. While the focus of microfluidic application in IVF has centered on embryo culture, the innovative platforms carry tremendous potential to improve other procedural steps and represents a possible paradigm shift in how we handle gametes and embryos. The following review will highlight application of various microfluidic platforms in IVF for use in maturation, manipulation, culture, cryopreservation and non-invasive quality assessment; pointing out new insights gained into functions of sperm, oocytes and embryos. Platform design and function will also be discussed, focusing on limitations, advancements and future refinements that can further aid in their clinical implementation.
Collapse
Affiliation(s)
- J E Swain
- Department of Obstetrics & Gynecology, University of Michigan, Ann Arbor, MI, USA
| | | | | | | |
Collapse
|
11
|
Esteves TC, van Rossem F, Nordhoff V, Schlatt S, Boiani M, Le Gac S. A microfluidic system supports single mouse embryo culture leading to full-term development. RSC Adv 2013. [DOI: 10.1039/c3ra44453h] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
|
12
|
Heo YS, Cabrera LM, Bormann CL, Smith GD, Takayama S. Real time culture and analysis of embryo metabolism using a microfluidic device with deformation based actuation. LAB ON A CHIP 2012; 12:2240-2246. [PMID: 22402469 DOI: 10.1039/c2lc21050a] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We report a computerized microfluidic real time embryo culture and assay device that can perform automated periodic analyses of embryo metabolism. This automated program uses a modified "gated injection" scheme (sample injection, reagent mixing, enzyme reaction of 15 min incubation, and sample detection) to sequentially measure fluorescence from sample, reference, and background (without any analyte) every hour. Measurements assessed with reference solutions demonstrated the stability of these microfluidic measurements over a 24 h period. Furthermore, this system was able to measure time dependent nutrient consumption by single or multiple (10) live mouse blastocyst-stage embryos with pmol h(-1) sensitivity. Mechanical deformation-based microfluidic actuation created by computerized movement of Braille pins enables automated fluid pumping and valving sequences without unwanted gravity-driven backflow or exposure to electrical fields as would be required in electrokinetic schemes. The convenient, non-invasive, and automated nature of these assays open the way for the development of integrated microfluidic platforms for practical single embryo culture and real time biochemical analysis to assess embryo viability and select embryos with the greatest implantation potential, thus improving success in clinical assisted reproductive technology laboratories.
Collapse
Affiliation(s)
- Yun Seok Heo
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | | | | | | | | |
Collapse
|
13
|
Swain JE, Smith GD. Advances in embryo culture platforms: novel approaches to improve preimplantation embryo development through modifications of the microenvironment. Hum Reprod Update 2011; 17:541-57. [PMID: 21454356 DOI: 10.1093/humupd/dmr006] [Citation(s) in RCA: 81] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND The majority of research aimed at improving embryo development in vitro has focused on manipulation of the chemical environment, examining details such as energy substrate composition and impact of various growth factors or other supplements. In comparison, relatively little work has been done examining the physical requirements of preimplantation embryos and the role culture platforms or devices can play in influencing embryo development. METHODS Electronic searches were performed using keywords centered on embryo culture techniques using PUBMED through June 2010 and references were searched for additional research articles. RESULTS Various approaches to in vitro embryo culture that involve manipulations of the physical culture environment are emerging. Novel culture platforms being developed examine issues such as media volume and embryo spacing. Furthermore, methods to permit dynamic embryo culture with fluid flow and embryo movement are now available, and novel culture surfaces are being tested. CONCLUSIONS Although several factors remain to be studied to optimize efficiency, manipulations of the embryo culture microenvironment through novel culture devices may offer a means to improve embryo development in vitro. Reduced volume systems that reduce embryo spacing, such as the well-of-the-well approach, appear beneficial, although more work is needed to verify the source of their true benefit in human embryos. Emerging microfluidic technology appears to be a promising approach. However, along with the work on specialized culture surfaces, more information is required to determine the impact on human embryo development.
Collapse
Affiliation(s)
- J E Swain
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI 48108, USA
| | | |
Collapse
|
14
|
Strovas TJ, McQuaide SC, Anderson JB, Nandakumar V, Kalyuzhnaya MG, Burgess LW, Holl MR, Meldrum DR, Lidstrom ME. Direct measurement of oxygen consumption rates from attached and unattached cells in a reversibly sealed, diffusionally isolated sample chamber. ACTA ACUST UNITED AC 2010; 5:398-408. [PMID: 21546993 DOI: 10.4236/abb.2010.15053] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Oxygen consumption is a fundamental component of metabolic networks, mitochondrial function, and global carbon cycling. To date there is no method available that allows for replicate measurements on attached and unattached biological samples without compensation for extraneous oxygen leaking into the system. Here we present the Respiratory Detection System, which is compatible with virtually any biological sample. The RDS can be used to measure oxygen uptake in microliter-scale volumes with a reversibly sealed sample chamber, which contains a porphyrin-based oxygen sensor. With the RDS, one can maintain a diffusional seal for up to three hours, allowing for the direct measurement of respiratory function of samples with fast or slow metabolic rates. The ability to easily measure oxygen uptake in small volumes with small populations or dilute samples has implications in cell biology, environmental biology, and clinical diagnostics.
Collapse
Affiliation(s)
- Timothy J Strovas
- Department of Electrical Engineering, University of Washington, Seattle, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Le Gac S, van den Berg A. Single cells as experimentation units in lab-on-a-chip devices. Trends Biotechnol 2009; 28:55-62. [PMID: 19914725 DOI: 10.1016/j.tibtech.2009.10.005] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2009] [Revised: 10/12/2009] [Accepted: 10/22/2009] [Indexed: 12/12/2022]
Abstract
'Lab-on-a-chip' technology (LOC) has now reached a mature state and is employed commonly in research in the life sciences. LOC devices make novel experimentation possible while providing a sophisticated environment for cellular investigation. As a next step, we introduce here the concept of a 'lab-in-a-cell': the use of a single cell as a minimal and highly confined experimental unit, or experimentation in the simple, but still unequalled, platform provided by nature itself. LOC provides the appropriate format and set of tools for LIC experimentation, and we discuss here three types of LIC investigation: the elucidation of signaling pathways; the creation of novel production units; and the use of microfluidics for assisted reproduction techniques.
Collapse
Affiliation(s)
- Séverine Le Gac
- BIOS The Lab-on-a-Chip Group, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | | |
Collapse
|