1
|
Smith de Diego A, Griffiths OV, Johnson MP, de Montis M, Hughes MP. Optimization of upstream particle concentration from flow using AC electro-osmosis and dielectrophoresis. BIOMICROFLUIDICS 2024; 18:024105. [PMID: 38585002 PMCID: PMC10997383 DOI: 10.1063/5.0189137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Accepted: 03/18/2024] [Indexed: 04/09/2024]
Abstract
There are many applications where upstream sample processing is required to concentrate dispersed particles in flow; this may be to increase the concentration (e.g., to enhance biosensor accuracy) or to decrease it (e.g., by removing contaminants from flow). The AC electrokinetic phenomenon, dielectrophoresis (DEP), has been used widely for particle trapping for flow, but the magnitude of the force drops reduces rapidly with distance from electrode edges, so that nm-scale particles such as viruses and bacteria are only trapped when near the electrode surface. This limits the usable flow rate in the device and can render the final device unusable for practical applications. Conversely, another electrokinetic phenomenon, AC electro-osmosis (ACEO), can be used to move particles to electrode surfaces but is unable to trap them from flow, limiting their ability for sample cleanup or trap-and-purge concentration. In this paper, we describe the optimization of ACEO electrodes aligned parallel to pressure-driven flow as a precursor/preconditioner to capture particles from a flow stream and concentrate them adjacent to the channel wall to enhance DEP capture. This is shown to be effective at flow rates of up to 0.84 ml min-1. Furthermore, the analysis of the 3D flow structure in the ACEO device by both simulation and confocal microscopy suggests that while the system offers significant benefits, the flow structure in the volume near the channel lid is such that while substantial trapping can occur, particles in this part of the chamber cannot be trapped, independent of the chamber height.
Collapse
Affiliation(s)
| | - Oreoluwa V. Griffiths
- Centre for Biomedical Engineering, University of Surrey, Guildford, Surrey GU2 7XH, United Kingdom
| | - Matthew P. Johnson
- Centre for Biomedical Engineering, University of Surrey, Guildford, Surrey GU2 7XH, United Kingdom
| | - Marco de Montis
- Kromek Ltd, Thomas Wright Way, Sedgefield, County Durham, TS21 3FD, United Kingdom
| | | |
Collapse
|
2
|
Vishwanathan G, Juarez G. Synchronous oscillatory electro-inertial focusing of microparticles. BIOMICROFLUIDICS 2023; 17:064105. [PMID: 38098691 PMCID: PMC10718650 DOI: 10.1063/5.0162368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 11/22/2023] [Indexed: 12/17/2023]
Abstract
Here, results are presented on the focusing of 1 μ m polystyrene particle suspensions using a synchronous oscillatory pressure-driven flow and oscillatory electric field in a microfluidic device. The effect of the phase difference between the oscillatory fields on the focusing position and focusing efficiency was investigated. The focusing position of negatively charged polystyrene particles could be tuned anywhere between the channel centerline to the channel walls. Similarly, the focusing efficiency could range from 20% up to 90%, depending on the phase difference, for particle Reynolds numbers of order O ( 10 - 4 ) . The migration velocity profile was measured and the peak velocity was found to scale linearly with both the oscillatory pressure-driven flow amplitude and the oscillatory electric field amplitude. Furthermore, the average migration velocity was observed to scale with the cosine of the phase difference between the fields, indicating the coupled non-linear nature of the phenomenon. Last, the peak migration velocity was measured for different particle radii and found to have an inverse relation, where the velocity increased with decreasing particle radius for identical conditions.
Collapse
Affiliation(s)
- Giridar Vishwanathan
- Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois 61801, USA
| | - Gabriel Juarez
- Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois 61801, USA
| |
Collapse
|
3
|
Mehta SK, Mondal PK. AC Electrothermal Effect Promotes Enhanced Solute Mixing in a Wavy Microchannel. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:16797-16806. [PMID: 37882459 DOI: 10.1021/acs.langmuir.3c02150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
For liquids used in biological applications, a smaller diffusion coefficient results in a longer mixing time. We discuss, in this endeavor, the promising potential of the AC electrothermal (ACET) effect toward modulating enhanced mixing of electrolytic liquids with higher convective strength in a novel wavy micromixer. To this end, we develop a modeling framework and numerically solve the pertinent transport equations in a three-dimensional (3D) configuration numerically. By benchmarking the developed modeling framework with the experimental results available in this paradigm, we aptly demonstrate the maximum temperature rise, flow topology, species concentration field, and mixing efficiency in the proposed configuration for a set of parameters pertinent to this analysis. We find that the maximum temperature increase in the wavy micromixer, owing to the electrothermal effect, is less than 10 K even for the higher strength of the applied voltage, implying nondegradation of biological substances within the liquid sample. We report that the formation of significant lateral flow closer to the electrodes leads to a highly three-dimensional ACET flow field, which has a significant impact on the mixing efficiency for the range of diffusive Peclet numbers considered. We also report that the wave amplitude of the mixer, when intervening with the diffusive Peclet number, strongly impacts the mixing efficiency. As witnessed in this endeavor, for the smaller diffusive Peclet number, the mixing efficiency increases with amplitude, while the effect becomes the opposite for the higher Peclet number. The results of this study seem to provide an adequate basis for the design of a novel micromixer intended for enhanced solute mixing in realistic microfluidic applications.
Collapse
Affiliation(s)
- Sumit Kumar Mehta
- Microfluidics and Microscale Transport Processes Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India
| | - Pranab Kumar Mondal
- Microfluidics and Microscale Transport Processes Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India
- School of Agro and Rural Technology, Indian Institute of Technology Guwahati, Guwahati 781039, India
| |
Collapse
|
4
|
Wang X, Liu Z, Wang B, Cai Y, Song Q. An overview on state-of-art of micromixer designs, characteristics and applications. Anal Chim Acta 2023; 1279:341685. [PMID: 37827660 DOI: 10.1016/j.aca.2023.341685] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 07/31/2023] [Accepted: 08/01/2023] [Indexed: 10/14/2023]
Abstract
Micromixers are characterized based on characteristics such as excellent mixing efficiency, low reagent cost and flexible controllability compared with conventional reactors in terms of macro size. A variety of designs and applications of micromixers have been proposed. The focus of current reviews is restricted to micromixer structures. Each type of micromixer has characteristics corresponding to its structure, which determines the suitable application areas. This paper provides an overview connecting micromixer designs and their applications. First, the typical designs and mixing mechanisms of both passive and active micromixers are summarized. Then, application cases of micromixers, including chemical, biological and medical applications, are presented. The characteristics, including the advantages and restrictions of different micromixers, are discussed. Finally, the future perspective of micromixer design is proposed. It is predictable that micromixers will have widespread applications by integrating two or more different mixing methods together. This review would be beneficial to guide the design of micromixers applied for specific purposes.
Collapse
Affiliation(s)
- Xin Wang
- School of Mechanical Engineering, Shandong University, Jinan 250061, Shandong, China; Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE/Key National Demonstration Center for Experimental Mechanical Engineering Education, Jinan 250061, Shandong, China
| | - Zhanqiang Liu
- School of Mechanical Engineering, Shandong University, Jinan 250061, Shandong, China; Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE/Key National Demonstration Center for Experimental Mechanical Engineering Education, Jinan 250061, Shandong, China.
| | - Bing Wang
- School of Mechanical Engineering, Shandong University, Jinan 250061, Shandong, China; Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE/Key National Demonstration Center for Experimental Mechanical Engineering Education, Jinan 250061, Shandong, China
| | - Yukui Cai
- School of Mechanical Engineering, Shandong University, Jinan 250061, Shandong, China; Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE/Key National Demonstration Center for Experimental Mechanical Engineering Education, Jinan 250061, Shandong, China
| | - Qinghua Song
- School of Mechanical Engineering, Shandong University, Jinan 250061, Shandong, China; Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE/Key National Demonstration Center for Experimental Mechanical Engineering Education, Jinan 250061, Shandong, China
| |
Collapse
|
5
|
Draz MS, Dupouy D, Gijs MAM. Acoustofluidic large-scale mixing for enhanced microfluidic immunostaining for tissue diagnostics. LAB ON A CHIP 2023. [PMID: 37365861 DOI: 10.1039/d3lc00312d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2023]
Abstract
The usage of microfluidics for automated and fast immunoassays has gained a lot of interest in the last decades. This integration comes with certain challenges, like the reconciliation of laminar flow patterns of micro-scale systems with diffusion-limited mass transport. Several methods have been investigated to enhance microfluidic mixing in microsystems, including acoustic-based fluidic streaming. Here, we report both by numerical simulation and experiments on the beneficiary effect of acoustic agitation on the uniformity of immunostaining in large-size and thin microfluidic chambers. Moreover, we investigate by numerical simulation the impact of reducing the incubation times and the concentrations of the biochemical detection reagents on the obtained immunoassay signal. Finally, acoustofluidic mixing was successfully used to reduce by 80% the incubation time of the Her2 (human epidermal growth factor receptor 2) and CK (cytokeratins) biomarkers for the spatial immunostaining of breast cancer cell pellets, or reducing their concentration by 66% and achieving a higher signal-to-background ratio than comparable spatially resolved immunostaining with static incubation.
Collapse
Affiliation(s)
- Muaz S Draz
- Laboratory of Microsystems 2, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland.
- Lunaphore Technologies SA, CH-1131 Tolochenaz, Switzerland
| | - Diego Dupouy
- Lunaphore Technologies SA, CH-1131 Tolochenaz, Switzerland
| | - Martin A M Gijs
- Laboratory of Microsystems 2, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland.
| |
Collapse
|
6
|
Draz MS, Uning K, Dupouy D, Gijs MAM. Efficient AC electrothermal flow (ACET) on-chip for enhanced immunoassays. LAB ON A CHIP 2023; 23:1637-1648. [PMID: 36644814 DOI: 10.1039/d2lc01147f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Biochemical reaction rates in microfluidic systems are known to be limited by the diffusional transport of reagents, leading often to lowered sensitivity and/or longer detection times in immunoassays. Several methods, including electrically powering electrodes to generate AC electrothermal flow (ACET) on-chip, have been adopted to enhance the mass transport of the reagents and improve microfluidic mixing. Here, we report a novel ACET electrode design concept for generating in-plane microfluidic mixing vortices that act over a large volume close to the reaction surface of interest. This is different from the traditional ACET parallel electrode design that provides rather local vertical mixing vortices directly above the electrodes. Both numerical simulation and experimental studies were performed to validate the new design. Moreover, numerical simulation was carried out to show the effects of experimental factors such as the reaction kinetics (association constant) and the reagent concentration on the ACET-enhanced surface-based assays. As a proof of concept, the new design for the ACET-enhanced immunoassays was used to improve the immunostaining signal of the HER2 (human epidermal growth factor receptor 2) cancer biomarker on breast cancer cells. Finally, the concept of scaling up the design has been validated by experiments (immunoassays on breast cancer cells for different ACET power and different assay times). In particular, we show that larger ACET in-plane designs can agitate and mix the fluid over large microfluidic volumes, which further enhances the immunoassay's output. We have achieved a 6-times enhancement in the assay signal with a 75% reduction in assay time.
Collapse
Affiliation(s)
- Muaz S Draz
- Laboratory of Microsystems 2, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland.
- Lunaphore Technologies SA, CH-1131 Tolochenaz, Switzerland
| | - Kevin Uning
- Laboratory of Microsystems 2, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland.
| | - Diego Dupouy
- Lunaphore Technologies SA, CH-1131 Tolochenaz, Switzerland
| | - Martin A M Gijs
- Laboratory of Microsystems 2, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland.
| |
Collapse
|
7
|
Gupta D, Nyande BW, Thomas KM, Li F, Mak AT, Lakerveld R. Induced-Charge Electroosmosis for Rapid Mixing of Reactive Precipitation Systems to Obtain Small and Uniform Particles. Chem Eng Res Des 2023. [DOI: 10.1016/j.cherd.2022.12.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
8
|
Electro-thermal actuated micromixer with VU/VIU/VUVIU/VIUVU patterned microgrooves. BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING 2022. [DOI: 10.1007/s43153-022-00293-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
9
|
Katzmeier F, Altaner B, List J, Gerland U, Simmel FC. Emergence of Colloidal Patterns in ac Electric Fields. PHYSICAL REVIEW LETTERS 2022; 128:058002. [PMID: 35179936 DOI: 10.1103/physrevlett.128.058002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 11/03/2021] [Accepted: 01/10/2022] [Indexed: 06/14/2023]
Abstract
Suspended microparticles subjected to ac electrical fields collectively organize into band patterns perpendicular to the field direction. The bands further develop into zigzag shaped patterns, in which the particles are observed to circulate. We demonstrate that this phenomenon can be observed quite generically by generating such patterns with a wide range of particles: silica spheres, fatty acid, oil, and coacervate droplets, bacteria, and ground coffee. We show that the phenomenon can be well understood in terms of second order electrokinetic flow, which correctly predicts the hydrodynamic interactions required for the pattern formation process. Brownian particle simulations based on these interactions accurately recapitulate all of the observed pattern formation and symmetry-breaking events, starting from a homogeneous particle suspension. The emergence of the formed patterns can be predicted quantitatively within a parameter-free theory.
Collapse
Affiliation(s)
- Florian Katzmeier
- Physics Department E14 and T37, TU Munich, D-85748 Garching, Germany
| | - Bernhard Altaner
- Physics Department E14 and T37, TU Munich, D-85748 Garching, Germany
| | - Jonathan List
- Physics Department E14 and T37, TU Munich, D-85748 Garching, Germany
| | - Ulrich Gerland
- Physics Department E14 and T37, TU Munich, D-85748 Garching, Germany
| | | |
Collapse
|
10
|
Bolze H, Riewe J, Bunjes H, Dietzel A, Burg TP. Continuous Production of Lipid Nanoparticles by Ultrasound‐Assisted Microfluidic Antisolvent Precipitation. Chem Eng Technol 2021. [DOI: 10.1002/ceat.202100149] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Holger Bolze
- Max-Planck Institute for Biophysical Chemisty Research Group Biological Micro- and Nanotechnology Am Fassberg 11 37077 Göttingen Germany
- Technische Universität Darmstadt Department of Electrical Engineering and Information Technology Merckstr. 25 64283 Darmstadt Germany
| | - Juliane Riewe
- Technische Universität Braunschweig Institut für Pharmazeutische Technologie und Biopharmazie Mendelssohnstr. 1 38106 Braunschweig Germany
- Technische Universität Braunschweig PVZ – Center of Pharmaceutical Engineering Franz-Liszt-Str. 35a 38106 Braunschweig Germany
| | - Heike Bunjes
- Technische Universität Braunschweig Institut für Pharmazeutische Technologie und Biopharmazie Mendelssohnstr. 1 38106 Braunschweig Germany
- Technische Universität Braunschweig PVZ – Center of Pharmaceutical Engineering Franz-Liszt-Str. 35a 38106 Braunschweig Germany
| | - Andreas Dietzel
- Technische Universität Braunschweig Institute of Microtechnology Alte Salzdahlumer Str. 203 38124 Braunschweig Germany
- Technische Universität Braunschweig PVZ – Center of Pharmaceutical Engineering Franz-Liszt-Str. 35a 38106 Braunschweig Germany
| | - Thomas P. Burg
- Max-Planck Institute for Biophysical Chemisty Research Group Biological Micro- and Nanotechnology Am Fassberg 11 37077 Göttingen Germany
- Technische Universität Darmstadt Department of Electrical Engineering and Information Technology Merckstr. 25 64283 Darmstadt Germany
- Technische Universität Darmstadt Centre for Synthetic Biology Rundeturmstraße 12 64283 Darmstadt Germany
| |
Collapse
|
11
|
Shi L, Ding H, Zhong X, Yin B, Liu Z, Zhou T. Mixing Mechanism of Microfluidic Mixer with Staggered Virtual Electrode Based on Light-Actuated AC Electroosmosis. MICROMACHINES 2021; 12:mi12070744. [PMID: 34202893 PMCID: PMC8306084 DOI: 10.3390/mi12070744] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 06/13/2021] [Accepted: 06/23/2021] [Indexed: 02/02/2023]
Abstract
In this paper, we present a novel microfluidic mixer with staggered virtual electrode based on light-actuated AC electroosmosis (LACE). We solve the coupled system of the flow field described by Navier–Stokes equations, the described electric field by a Laplace equation, and the concentration field described by a convection–diffusion equation via a finite-element method (FEM). Moreover, we study the distribution of the flow, electric, and concentration fields in the microchannel, and reveal the generating mechanism of the rotating vortex on the cross-section of the microchannel and the mixing mechanism of the fluid sample. We also explore the influence of several key geometric parameters such as the length, width, and spacing of the virtual electrode, and the height of the microchannel on mixing performance; the relatively optimal mixer structure is thus obtained. The current micromixer provides a favorable fluid-mixing method based on an optical virtual electrode, and could promote the comprehensive integration of functions in modern microfluidic-analysis systems.
Collapse
Affiliation(s)
- Liuyong Shi
- Mechanical and Electrical Engineering College, Hainan University, Haikou 570228, China; (L.S.); (H.D.); (X.Z.)
| | - Hanghang Ding
- Mechanical and Electrical Engineering College, Hainan University, Haikou 570228, China; (L.S.); (H.D.); (X.Z.)
| | - Xiangtao Zhong
- Mechanical and Electrical Engineering College, Hainan University, Haikou 570228, China; (L.S.); (H.D.); (X.Z.)
| | - Binfeng Yin
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China;
| | - Zhenyu Liu
- Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China;
| | - Teng Zhou
- Mechanical and Electrical Engineering College, Hainan University, Haikou 570228, China; (L.S.); (H.D.); (X.Z.)
- Correspondence: ; Tel.: +86-186-8963-7366
| |
Collapse
|
12
|
Hu Z, Zhao T, Zhao W, Yang F, Wang H, Wang K, Bai J, Wang G. Transition from periodic to chaotic
AC
electroosmotic flows near electric double layer. AIChE J 2021. [DOI: 10.1002/aic.17148] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Zhongyan Hu
- State Key Laboratory of Photon‐Technology in Western China Energy, International Scientific and Technological Cooperation Base of Photoelectric Technology and Functional Materials and Application, Institute of Photonics and Photon‐Technology Northwest University Xi'an 710127 China
| | - Tianyun Zhao
- School of Automation Northwestern Polytechnical University Xi'an China
| | - Wei Zhao
- State Key Laboratory of Photon‐Technology in Western China Energy, International Scientific and Technological Cooperation Base of Photoelectric Technology and Functional Materials and Application, Institute of Photonics and Photon‐Technology Northwest University Xi'an 710127 China
- Department of Mechanical Engineering & Biomedical Engineering Program University of South Carolina Columbia South Carolina USA
| | - Fang Yang
- Key Laboratory for Molecular Enzymology and Engineering of Ministry of Education Jilin University Changchun P.R. China
| | - Hongxun Wang
- Aeronautics Engineering College Air Force Engineering University Xi'an China
| | - Kaige Wang
- State Key Laboratory of Photon‐Technology in Western China Energy, International Scientific and Technological Cooperation Base of Photoelectric Technology and Functional Materials and Application, Institute of Photonics and Photon‐Technology Northwest University Xi'an 710127 China
| | - Jintao Bai
- State Key Laboratory of Photon‐Technology in Western China Energy, International Scientific and Technological Cooperation Base of Photoelectric Technology and Functional Materials and Application, Institute of Photonics and Photon‐Technology Northwest University Xi'an 710127 China
| | - Guiren Wang
- State Key Laboratory of Photon‐Technology in Western China Energy, International Scientific and Technological Cooperation Base of Photoelectric Technology and Functional Materials and Application, Institute of Photonics and Photon‐Technology Northwest University Xi'an 710127 China
- Department of Mechanical Engineering & Biomedical Engineering Program University of South Carolina Columbia South Carolina USA
| |
Collapse
|
13
|
Sun H, Ren Y, Tao Y, Jiang T, Jiang H. Three-Fluid Sequential Micromixing-Assisted Nanoparticle Synthesis Utilizing Alternating Current Electrothermal Flow. Ind Eng Chem Res 2020. [DOI: 10.1021/acs.iecr.0c02068] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Haizhen Sun
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China
| | - Yukun Ren
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China
| | - Ye Tao
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China
| | - Tianyi Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China
| | - Hongyuan Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China
| |
Collapse
|
14
|
Huo X, Chen X. A review on modeling, simulation and experiment of electrokinetic micromixers. J DISPER SCI TECHNOL 2020. [DOI: 10.1080/01932691.2020.1773847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Xuyao Huo
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| | - Xueye Chen
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| |
Collapse
|
15
|
Zhang K, Ren Y, Tao Y, Deng X, Liu W, Jiang T, Jiang H. Efficient particle and droplet manipulation utilizing the combined thermal buoyancy convection and temperature-enhanced rotating induced-charge electroosmotic flow. Anal Chim Acta 2020; 1096:108-119. [DOI: 10.1016/j.aca.2019.10.044] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2019] [Revised: 09/09/2019] [Accepted: 10/21/2019] [Indexed: 01/04/2023]
|
16
|
Lijnse T, Cenaiko S, Dalton C. Numerical simulation of a tuneable reversible flow design for practical ACET devices. SN APPLIED SCIENCES 2020. [DOI: 10.1007/s42452-020-2098-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
AbstractAlternating Current Electrothermal (ACET) micropumps are a well-documented flow induction and mixing method. This phenomenon has significant promise as a reliable microfluidic pumping method for high conductivity biofluids, such as cerebrospinal fluid, urine, or blood. Practical implementations so far have been limited by complex designs focused on maximized flow rates, typically in only one direction at a time. This paper describes a device geometry demonstrating, and quantifying for the first time, fully reversible flow, that is, going from 100% flow in one direction to fully symmetrical 100% flow in the opposite direction. This design incorporates multiple features targeted at practical fabrication and applications. The design enables fine-tuning of flow speeds via adjustable signal strengths in a unique manner compared to traditional ACET devices. A full numerical simulation of this device has been performed within this work. Additionally, this paper reports several methods for increasing usability of ACET devices, including proposing coatings to prevent electrolysis and increase flow rates without the risk of fluid reactions, manufacturing methods for ease of handling, and specific device parameters for implementation in microdevices. The development of an ACET device that can precisely and efficiently pump and extract fluids allows for new applications in integrated biological systems and monitoring devices.
Collapse
|
17
|
Modarres P, Tabrizian M. Phase-controlled field-effect micromixing using AC electroosmosis. MICROSYSTEMS & NANOENGINEERING 2020; 6:60. [PMID: 34567671 PMCID: PMC8433414 DOI: 10.1038/s41378-020-0166-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Accepted: 02/05/2020] [Indexed: 05/08/2023]
Abstract
The exploration and application of electrokinetic techniques in micro total analysis systems have become ubiquitous in recent years, and scientists are expanding the use of such techniques in areas where comparable active or passive methods are not as successful. In this work, for the first time, we utilize the concept of AC electroosmosis to design a phase-controlled field-effect micromixer that benefits from a three-finger sinusoidally shaped electrodes. Analogous to field-effect transistor devices, the principle of operation for the proposed micromixer is governed by the source-gate and source-drain voltage potentials that are modulated by introducing a phase lag between the driving electrodes. At an optimized flow rate and biasing scheme, we demonstrate that the source, gate, and drain voltage phase relations can be configured such that the micromixer switches from an unmixed state (phase shift of 0°) to a mixed state (phase shift of 180°). High mixing efficiencies beyond 90% was achieved at a volumetric flow rate of 4 µL/min corresponding to ~13.9 mm/s at optimized voltage excitation conditions. Finally, we employed the proposed micromixer for the synthesis of nanoscale lipid-based drug delivery vesicles through the process of electrohydrodynamic-mediated nanoprecipitation. The phase-controlled electrohydrodynamic mixing utilized for the nanoprecipitation technique proved that nanoparticles of improved monodispersity and concentration can be produced when mixing efficiency is enhanced by tuning the phase shifts between electrodes.
Collapse
Affiliation(s)
- Paresa Modarres
- Biomedical Engineering Department, McGill University, Montreal, QC Canada
| | - Maryam Tabrizian
- Biomedical Engineering Department, McGill University, Montreal, QC Canada
- Faculty of Dentistry, McGill University, 2001 McGill College Ave, Montreal, QC Canada
| |
Collapse
|
18
|
Kunti G, Agarwal T, Bhattacharya A, Maiti TK, Chakraborty S. On-Chip Concentration and Patterning of Biological Cells Using Interplay of Electrical and Thermal Fields. Anal Chem 2019; 92:838-844. [PMID: 31769657 DOI: 10.1021/acs.analchem.9b03364] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Golak Kunti
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal - 721302, India
| | - Tarun Agarwal
- Department of Biotechnology, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal - 721302, India
| | - Anandaroop Bhattacharya
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal - 721302, India
| | - Tapas Kumar Maiti
- Department of Biotechnology, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal - 721302, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal - 721302, India
| |
Collapse
|
19
|
Li J, Hill EH, Lin L, Zheng Y. Optical Nanoprinting of Colloidal Particles and Functional Structures. ACS NANO 2019; 13:3783-3795. [PMID: 30875190 PMCID: PMC6482071 DOI: 10.1021/acsnano.9b01034] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Recent advances in chemical sciences have enabled the tailorable synthesis of colloidal particles with variable composition, size, shape, and properties. Building superstructures with colloidal particles as building blocks is appealing for the fabrication of functional metamaterials and nanodevices. Optical nanoprinting provides a versatile platform to print various particles into arbitrary configurations with nanometric precision. In this review, we summarize recent progress in optical nanoprinting of colloidal particles and its related applications. Diverse techniques based on different physical mechanisms, including optical forces, light-controlled electric fields, optothermal effects, laser-directed thermocapillary flows, and photochemical reactions, are discussed in detail. With its flexible and versatile capabilities, optical nanoprinting will find promising applications in numerous fields such as nanophotonics, energy, microelectronics, and nanomedicine.
Collapse
Affiliation(s)
- Jingang Li
- Department of Mechanical Engineering, Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Eric H. Hill
- Institute of Advanced Ceramics, Hamburg University of Technology, 21073 Hamburg, Germany
| | - Linhan Lin
- Department of Mechanical Engineering, Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Yuebing Zheng
- Department of Mechanical Engineering, Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
20
|
Lee S, Lee W, Kim H, Bae PK, Park J, Kim J. Oscillatory flow-assisted efficient target enrichment with small volumes of sample by using a particle-based microarray device. Biosens Bioelectron 2019; 131:280-286. [PMID: 30849728 DOI: 10.1016/j.bios.2019.01.067] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 01/21/2019] [Accepted: 01/27/2019] [Indexed: 01/03/2023]
Abstract
In the study, we describe an oscillatory flow-assisted efficient target enrichment method by using a particle-based microarray device. Periodic oscillating flow effectively increased the mixing and binding performance between the target molecules in the sample solution and surface functionalized microparticles. Particles were trapped, secured, and released with an elastic microvalve structure operated via differences in the flow conditions. Single particle (20-µm diameter) trapping efficiency exceeded 95%. Secured particles can freely move inside each array element based on oscillating sample flow. Furthermore, the particles can be released from the array and collected at the outlet of the device, and this provides an opportunity for further off-chip analysis. As a proof-of-concept, we used the interaction between streptavidin-coated microparticles and fluorescence labeled biotin solution and demonstrated that target enrichment and detection based on oscillatory flow were significantly more efficient than that based on unidirectional or static flow. The applicability of the method was further examined by conducting an on-chip immunoassay to detect the presence of anti-Zika nonstructural protein 1 (NS1) monoclonal antibody. The limit of detection (LOD) was as low as 1 ng/mL with an assay time of only 10 min and less than 10 µL of sample consumption.
Collapse
Affiliation(s)
- Sanghyun Lee
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Wonhyung Lee
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Hojin Kim
- BioMEMS Lab., RadianQbio, 53 Gasan Digital 2-Ro, Geumcheon-Gu, Seoul 08588, Republic of Korea
| | - Pan Kee Bae
- BioNano Health Guard Research Center, 125 Gwahak-Ro, Yuseong-Gu, Daejeon 34141, Republic of Korea
| | - Jaechan Park
- Department of Neurosurgery, School of Medicine, Kyungpook National University, 680 Gukchaebosang-Ro, Jung-Gu, Daegu 41944, Republic of Korea
| | - Joonwon Kim
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk 37673, Republic of Korea.
| |
Collapse
|
21
|
Sakurai R, Yamamoto K, Motosuke M. Concentration-adjustable micromixers using droplet injection into a microchannel. Analyst 2019; 144:2780-2787. [PMID: 30869661 DOI: 10.1039/c8an02310g] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel micromixing technique that exploits a thrust of droplets into the mixing interface is developed. The technique enhances the mixing by injecting immiscible droplets into a mixing channel and the methodology enables control of the mixing level simply by changing the droplet injection frequency. We experimentally characterize the mixing performance with various droplet injection frequencies, channel geometries, and diffusion coefficients. Consequently, it is revealed that the mixing level increases with the injection frequency, the droplet-diameter-to-channel-width ratio, and the diffusion coefficient. Moreover, the mixing level is found to be a linear function of the droplet volume fraction in the mixing section. The results suggest that the developed device can produce a large amount of sample solution whose concentration is arbitrary and precisely controllable with a simple and stable operation.
Collapse
Affiliation(s)
- Ryosuke Sakurai
- Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan.
| | - Ken Yamamoto
- Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan. and Research Institute for Science and Technology, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| | - Masahiro Motosuke
- Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan. and Research Institute for Science and Technology, Tokyo University of Science, 6-3-1 Niijuku, Katsushika-ku, Tokyo 125-8585, Japan
| |
Collapse
|
22
|
Salari A, Dalton C. Simultaneous Pumping and Mixing of Biological Fluids in a Double-Array Electrothermal Microfluidic Device. MICROMACHINES 2019; 10:mi10020092. [PMID: 30696037 PMCID: PMC6413218 DOI: 10.3390/mi10020092] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Revised: 01/18/2019] [Accepted: 01/25/2019] [Indexed: 11/29/2022]
Abstract
Transport and mixing of minute amounts of biological fluids are significantly important in lab-on-a-chip devices. It has been shown that the electrothermal technique is a suitable candidate for applications involving high-conductivity biofluids, such as blood, saliva, and urine. Here, we introduce a double-array AC electrothermal (ACET) device consisting of two opposing microelectrode arrays, which can be used for simultaneous mixing and pumping. First, in a 2D simulation, an optimum electrode-pair configuration capable of achieving fast transverse mixing at a microfluidic channel cross-section is identified by comparing different electrode geometries. The results show that by adjusting the applied voltage pattern and position of the asymmetrical microelectrodes in the two arrays, due to the resultant circular flow streamlines, the time it takes for the analytes to be convected across the channel cross-section is reduced by 95% compared to a diffusion-only-based transport regime, and by 80% compared to a conventional two-layer ACET device. Using a 3D simulation, the fluid transport (pumping and mixing) capabilities of such an electrode pair placed at different angles longitudinally relative to the channel was studied. It was found that an asymmetrical electrode configuration placed at an angle in the range of 30°≤θ≤45° can significantly increase transversal mixing efficiency while generating strong longitudinal net flow. These findings are of interest for lab-on-a-chip applications, especially for biosensors and immunoassays, where mixing analyte solutions while simultaneously moving them through a microchannel can greatly enhance the sensing efficiency.
Collapse
Affiliation(s)
- Alinaghi Salari
- Biomedical Engineering Graduate Program, Ryerson University, Toronto, ON M5B 2K3, Canada.
- Institute for Biomedical Engineering, Science and Technology (iBEST), St. Michael's Hospital, Toronto, ON M5B 1T8, Canada.
- Keenan Research Centre, St. Michael's Hospital, Toronto, ON M5B 1T8, Canada.
| | - Colin Dalton
- Electrical and Computer Engineering Department, University of Calgary, Calgary, AB T2N 1N4, Canada.
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB T2N 1N4, Canada.
| |
Collapse
|
23
|
Mukherjee S, Dhar J, DasGupta S, Chakraborty S. Patterned surface charges coupled with thermal gradients may create giant augmentations of solute dispersion in electro-osmosis of viscoelastic fluids. Proc Math Phys Eng Sci 2019; 475:20180522. [PMID: 30760958 DOI: 10.1098/rspa.2018.0522] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 11/29/2018] [Indexed: 12/14/2022] Open
Abstract
Augmenting the dispersion of a solute species and fluidic mixing remains a challenging proposition in electrically actuated microfluidic devices, primarily due to an inherent plug-like nature of the velocity profile under uniform surface charge conditions. While a judicious patterning of surface charges may obviate some of the concerning challenges, the consequent improvement in solute dispersion may turn out to be marginal. Here, we show that by exploiting a unique coupling of patterned surface charges with intrinsically induced thermal gradients, it may be possible to realize giant augmentations in solute dispersion in electro-osmotic flows. This is effectively mediated by the phenomena of Joule heating and surface heat dissipation, so as to induce local variations in electrical properties. Combined with the rheological premises of a viscoelastic fluid that are typically reminiscent of common biofluids handled in lab-on-a-chip-based micro-devices, our results demonstrate that the consequent electro-hydrodynamic forcing may open up favourable windows for augmented hydrodynamic dispersion, which has not yet been unveiled.
Collapse
Affiliation(s)
- Siddhartha Mukherjee
- Advanced Technology Development Center, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Jayabrata Dhar
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Sunando DasGupta
- Advanced Technology Development Center, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.,Department of Chemical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Suman Chakraborty
- Advanced Technology Development Center, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.,Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
24
|
Mi S, Li B, Yi X, Xu Y, Du Z, Yang S, Li W, Sun W. An AC electrothermal self-circulating system with a minimalist process to construct a biomimetic liver lobule model for drug testing. RSC Adv 2018; 8:36987-36998. [PMID: 35557806 PMCID: PMC9089443 DOI: 10.1039/c8ra03724h] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Accepted: 09/27/2018] [Indexed: 01/09/2023] Open
Abstract
Liver-on-chip, due to its precision and low cost for constructing in vitro models, has tremendous potential for drug toxicity testing and pathological studies. By applying APAP (acetaminophen) treatment of different concentrations, a dynamic self-circulating liver lobule model for drug testing was proven useful for emulating the human physiological system. However, the demand for a dynamic system of on-chip organs is difficult to fulfil due to the relatively cumbersome fabrication processes. In this paper, the design and fabrication of an AC electrothermal self-circulating system combined with a 3D biomimetic liver lobule is described. The system was fabricated using a low-cost ITO laser etching process within a few seconds. A large number of interdigital electrodes were arranged in a limited space to increase the fluid flow-driven efficiency. The liver lobule consists of two parts, a hepatocyte cell-laden layer and an endothelial layer, which exhibit a sandwich radial shaped pattern that is more bionic in structure and function. By evaluating the velocity and temperature in the self-circulating system at various voltages and frequencies, we obtained a set of reliable input parameters to provide an adequate supply of culture fluid without cell damage. The metabolism of the liver lobule in dynamic culture and static culture was compared based on cell viability, albumin secretion and urea synthesis.
Collapse
Affiliation(s)
- Shengli Mi
- Graduate School at Shenzhen, Tsinghua University Shenzhen P. R. China +8675526036356 +8675526036329
- Open FIESTA Center, Tsinghua University Shenzhen 518055 PR China
| | - Baihan Li
- Graduate School at Shenzhen, Tsinghua University Shenzhen P. R. China +8675526036356 +8675526036329
| | - Xiaoman Yi
- Graduate School at Shenzhen, Tsinghua University Shenzhen P. R. China +8675526036356 +8675526036329
| | - Yuanyuan Xu
- Tsinghua-Berkeley Shenzhen Institute Shenzhen P. R. China
| | - Zhichang Du
- Graduate School at Shenzhen, Tsinghua University Shenzhen P. R. China +8675526036356 +8675526036329
| | - Shuaitao Yang
- Graduate School at Shenzhen, Tsinghua University Shenzhen P. R. China +8675526036356 +8675526036329
| | - Wei Li
- Department of Mechanical Engineering, The University of Texas at Austin Austin Texas 78712 USA
| | - Wei Sun
- Graduate School at Shenzhen, Tsinghua University Shenzhen P. R. China +8675526036356 +8675526036329
- Department of Mechanical Engineering and Mechanics, Tsinghua University Beijing China
- Department of Mechanical Engineering, Drexel University Philadelphia PA USA
- Tsinghua-Berkeley Shenzhen Institute Shenzhen P. R. China
| |
Collapse
|
25
|
Ren Y, Song C, Liu W, Jiang T, Song J, Wu Q, Jiang H. On hybrid electroosmotic kinetics for field-effect-reconfigurable nanoparticle trapping in a four-terminal spiral microelectrode array. Electrophoresis 2018; 40:979-992. [DOI: 10.1002/elps.201800325] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Revised: 09/09/2018] [Accepted: 09/22/2018] [Indexed: 01/16/2023]
Affiliation(s)
- Yukun Ren
- State Key Laboratory of Robotics and System; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
- The State Key Laboratory of Nonlinear Mechanics (LNM); Institute of Mechanics; Chinese Academy of Sciences; Beijing P. R. China
| | - Chunlei Song
- State Key Laboratory of Robotics and System; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| | - Weiyu Liu
- School of Electronics and Control Engineering, and School of Highway; Chang'an University; Xi'an Shaanxi P. R. China
| | - Tianyi Jiang
- State Key Laboratory of Robotics and System; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| | - Jingni Song
- School of Electronics and Control Engineering, and School of Highway; Chang'an University; Xi'an Shaanxi P. R. China
| | - Qisheng Wu
- School of Electronics and Control Engineering, and School of Highway; Chang'an University; Xi'an Shaanxi P. R. China
| | - Hongyuan Jiang
- State Key Laboratory of Robotics and System; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| |
Collapse
|
26
|
Lee HB, Inoue S, Kim JH, Jeong M, Chung JH. Electrokinetic Behavior of Heat-Treated Mycobacterium Bacillus Calmette-Guérin Cells. J Med Device 2018. [DOI: 10.1115/1.4040677] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Dielectrophoresis (DEP) can be an effective tool to show the physiological change of bacterial cells. The behavior of bacterial cells under an electric field is complicated due to the combined effects of electrokinetic phenomena. This paper presents the study of the electrokinetic behavior of heat-treated Mycobacterium bovis Bacillus Calmette-Guérin (BCG) cells for a cell counting method. Through numerical and experimental study, heat-treated BCG cells are compared with control BCG cells. At various frequencies with the medium conductivity of 0.07 S/m, the equilibrium positions of both control- and heat-treated cells are analyzed in the combined fields of DEP and AC electroosmosis (ACEO). As DEP changes from negative to positive in electroosmotic flow, the equilibrium position of cells is bifurcated from the upper center between two electrodes onto the edges of both electrodes. It was found that the cells floating on electrodes should not be counted as attracted cells because the floating was resulted from the combined effect of the negative DEP and ACEO. According to the analysis, an optimum frequency is proposed to differentiate control cells from heat-treated cells using a cell counting method. The presented study will offer physical insight for the cell counting to differentiate live and dead Mycobacterium bovis BCG cells treated with heat and drugs.
Collapse
Affiliation(s)
- Hyun-Boo Lee
- Department of Mechanical Engineering, University of Washington, P.O. Box 352600, Seattle, WA 98195 e-mail:
| | - Shinnosuke Inoue
- Department of Mechanical Engineering, University of Washington, P.O. Box 352600, Seattle, WA 98195 e-mail:
| | - Jong-Hoon Kim
- School of Engineering and Computer Science, Washington State University, Vancouver, WA 98686 e-mail:
| | - Minjoong Jeong
- National Supercomputing Center, Korea Institute of Science and Technology Information, Daejeon 34141, South Korea e-mail:
| | - Jae-Hyun Chung
- Department of Mechanical Engineering, University of Washington, P.O. Box 352600, Seattle, WA 98195 e-mail:
| |
Collapse
|
27
|
Gao X, Li Y. Biofluid pumping and mixing by an AC electrothermal micropump embedded with a spiral microelectrode pair in a cylindrical microchannel. Electrophoresis 2018; 39:3156-3170. [PMID: 30194859 DOI: 10.1002/elps.201800162] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 08/20/2018] [Accepted: 08/31/2018] [Indexed: 11/10/2022]
Abstract
In this paper, we numerically investigated a multifunctional AC electrothermal (ACET) micropump embedded with an asymmetric spiral microelectrode pair in a cylindrical microchannel for simultaneous pumping and mixing in high-conductivity fluids, which makes the pump useful for biofluid applications. When an AC signal was applied to the asymmetric spiral electrode pair, the vortices induced on the electrode surfaces with centerlines along the corresponding spiral electrode length exhibit a spiral distribution, and the net flow in the cylindrical microchannel is generated by the ACET effect. The vorticity field distribution can explain the mechanism of simultaneous pumping and mixing. Because the vorticity field is inclined against the microchannel direction, vortices on top of the spiral electrodes can affect the ACET flow in the following two aspects at the same time: one is pumping the flow in the microchannel direction, and the other is mixing the samples by stirring the flow. We also determined that the geometric ratios of the electrode width to the gap or slant angle of the spiral electrodes can feasibly be used to control the relative strength of the pumping and mixing capabilities, and we achieved an optimal design that gives both desirable pumping and mixing efficiencies. This study shows that the spiral ACET micropump design can rapidly drive the high-conductivity fluids and efficiently mix samples simultaneously. The numerical simulation of the spiral ACET micropump is of significant importance for practical, chemical and biological applications, and feasible fabrication techiniques should be experimentally investigated in future studies.
Collapse
Affiliation(s)
- Xiaobo Gao
- School of Physics and Engineering, Zhengzhou University, Zhengzhou, Henan, P. R. China
| | - Yuxiao Li
- School of Physics and Engineering, Zhengzhou University, Zhengzhou, Henan, P. R. China
| |
Collapse
|
28
|
Park S, Yossifon G. Electrothermal based active control of ion transport in a microfluidic device with an ion-permselective membrane. NANOSCALE 2018; 10:11633-11641. [PMID: 29896609 DOI: 10.1039/c8nr02389a] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The ability to induce regions of high and low ionic concentrations adjacent to a permselective membrane or a nanochannel subject to an externally applied electric field (a phenomenon termed concentration-polarization) has been used for a broad spectrum of applications ranging from on-chip desalination, bacteria filtration to biomolecule preconcentration. But these applications have been limited by the ability to control the length of the diffusion layer that is commonly indirectly prescribed by the fixed geometric and surface properties of a nanofluidic system. Here, we demonstrate that the depletion layer can be dynamically varied by inducing controlled electrothermal flow driven by the interaction of temperature gradients with the applied electric field. To this end, a series of microscale heaters, which can be individually activated on demand are embedded at the bottom of the microchannel and the relationship between their activation and ionic concentration is characterized. Such spatio-temporal control of the diffusion layer can be used to enhance on-chip electro-dialysis by producing shorter depletion layers, to dynamically reduce the microchannel resistance relative to that of the nanochannel for nanochannel based (bio)sensing, to generate current rectification reminiscent of a diode like behavior and control the location of the preconcentrated plug of analytes or the interface of brine and desalted streams.
Collapse
Affiliation(s)
- Sinwook Park
- Faculty of Mechanical Engineering, Micro- and Nanofluidics Laboratory, Technion - Israel Institute of Technology, Technion City 3200000, Israel.
| | | |
Collapse
|
29
|
Zhao W, Liu X, Yang F, Wang K, Bai J, Qiao R, Wang G. Study of Oscillating Electroosmotic Flows with High Temporal and Spatial Resolution. Anal Chem 2018; 90:1652-1659. [PMID: 29256244 DOI: 10.1021/acs.analchem.7b02985] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Near-wall velocity of oscillating electroosmotic flow (OEOF) driven by an AC electric field has been investigated using a laser-induced fluorescence photobleaching anemometer (LIFPA). For the first time, an up to 3 kHz velocity response of OEOF has been successfully measured experimentally, even though the oscillating velocity is as low as 600 nm/s. It is found that the oscillating velocity decays with the forcing frequency ff as ff-0.66. In the investigated range of electric field intensity (EA), below 1 kHz, the linear relation between oscillating velocity and EA is also observed. Because the oscillating velocity at high frequency is very small, the contribution of noise to velocity measurement is significant, and it is discussed in this manuscript. The investigation reveals the instantaneous response of OEOF to the temporal change of electric fields, which exists in almost all AC electrokinetic flows. Furthermore, the experimental observations are important for designing OEOF-based micro/nanofluidics systems.
Collapse
Affiliation(s)
- Wei Zhao
- Institute of Photonics and Photon-technology, International Scientific and Technological Cooperation Base of Photoelectric Technology and Functional Materials and Application, Northwest University , 229 North Taibai Road, Xi'an 710069, People's Republic of China.,Department of Mechanical Engineering & Biomedical Engineering Program, University of South Carolina , Columbia, South Carolina 29208, United States
| | - Xin Liu
- Department of Mechanical Engineering & Biomedical Engineering Program, University of South Carolina , Columbia, South Carolina 29208, United States
| | - Fang Yang
- Key Laboratory for Molecular Enzymology and Engineering of Ministry of Education, Jilin University , Changchun 130012, People's Republic of China
| | - Kaige Wang
- Institute of Photonics and Photon-technology, International Scientific and Technological Cooperation Base of Photoelectric Technology and Functional Materials and Application, Northwest University , 229 North Taibai Road, Xi'an 710069, People's Republic of China
| | - Jintao Bai
- Institute of Photonics and Photon-technology, International Scientific and Technological Cooperation Base of Photoelectric Technology and Functional Materials and Application, Northwest University , 229 North Taibai Road, Xi'an 710069, People's Republic of China
| | - Rui Qiao
- Department of Mechanical Engineering, Virginia Tech , Blacksburg, Virginia 24061, United States
| | - Guiren Wang
- Department of Mechanical Engineering & Biomedical Engineering Program, University of South Carolina , Columbia, South Carolina 29208, United States
| |
Collapse
|
30
|
Bachman H, Huang PH, Zhao S, Yang S, Zhang P, Fu H, Huang TJ. Acoustofluidic devices controlled by cell phones. LAB ON A CHIP 2018; 18:433-441. [PMID: 29302660 PMCID: PMC5989538 DOI: 10.1039/c7lc01222e] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Acoustofluidic devices have continuously demonstrated their potential to impact medical diagnostics and lab-on-a-chip applications. To bring these technologies to real-world applications, they must be made more accessible to end users. Herein, we report on the effort to provide an easy-to-use and portable system for controlling sharp-edge-based acoustofluidic devices. With the use of a cell phone and a modified Bluetooth® speaker, on-demand and hands-free pumping and mixing are achieved. Additionally, a novel design for a sharp-edge-based acoustofluidic device is proposed that combines both pumping and mixing functions into a single device, thus removing the need for external equipment typically needed to accomplish these two tasks. These applications serve to demonstrate the potential function that acoustofluidic devices can provide in point-of-care platforms. To further this point-of-care goal, we also design a portable microscope that combines with the cell phone and Bluetooth® power supply, providing a completely transportable acoustofluidic testing station. This work serves to bolster the promising position that acoustofluidic devices have within the rapidly changing research and diagnostics fields.
Collapse
Affiliation(s)
- Hunter Bachman
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA.
| | | | | | | | | | | | | |
Collapse
|
31
|
Funaki M, Suwa M, Watarai H. Electromagnetophoretic Micro-convection around a Droplet in a Capillary. ANAL SCI 2018; 33:1013-1019. [PMID: 28890484 DOI: 10.2116/analsci.33.1013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The electromagnetophoretic behavior of organic droplets in an electrolyte solution was investigated in a silica capillary cell using a superconducting bulk magnet (3.5 T) and a magnetic circuit (2.7 T). The initially dispersed emulsion droplets of dodecane migrated to the wall of the capillary, responding to the direction of an electric current, and coalesced to form smaller and larger droplets after some repeated migrations. When the electric current was applied continuously, the larger droplets became arranged with regular intervals on the wall, and smaller droplets rotated around the larger droplets. These interesting behaviors were analyzed while taking into account the local electric current density determined by the flow velocity of the ionic current around a droplet, which was lowest on the electrode sides of the droplet. The difference in the local electric current density generated the Lorentz-force difference in the medium, which lead to local micro-convection around the droplet, and also the alignment of larger droplets by a repelling effect between the adjacent micro-convections.
Collapse
Affiliation(s)
- Masuro Funaki
- Department of Chemistry, Graduate School of Science, Osaka University
| | - Masayori Suwa
- Department of Chemistry, Graduate School of Science, Osaka University
| | | |
Collapse
|
32
|
Ren Y, Liu X, Liu W, Tao Y, Jia Y, Hou L, Li W, Jiang H. Flexible particle flow-focusing in microchannel driven by droplet-directed induced-charge electroosmosis. Electrophoresis 2017; 39:597-607. [DOI: 10.1002/elps.201700305] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 10/25/2017] [Accepted: 10/25/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Yukun Ren
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
- State Key Laboratory of Robotics and System; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| | - Xianyu Liu
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| | - Weiyu Liu
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
- School of Electronics and Control Engineering; Chang'an University; Xi'an Shaanxi P. R. China
| | - Ye Tao
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| | - Yankai Jia
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| | - Likai Hou
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| | - Wenying Li
- Center for Applied Solid State Chemistry Research; Ningbo University; Ningbo P. R. China
| | - Hongyuan Jiang
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
- State Key Laboratory of Robotics and System; Harbin Institute of Technology; Harbin Heilongjiang P. R. China
| |
Collapse
|
33
|
Zhao W, Yang F, Wang K, Bai J, Wang G. Rapid mixing by turbulent-like electrokinetic microflow. Chem Eng Sci 2017. [DOI: 10.1016/j.ces.2017.02.027] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
34
|
Kunti G, Bhattacharya A, Chakraborty S. Rapid mixing with high-throughput in a semi-active semi-passive micromixer. Electrophoresis 2017; 38:1310-1317. [PMID: 28256732 DOI: 10.1002/elps.201600393] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Revised: 01/30/2017] [Accepted: 02/25/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Golak Kunti
- Department of Mechanical Engineering; Indian Institute of Technology Kharagpur; Kharagpur West Bengal India
| | - Anandaroop Bhattacharya
- Department of Mechanical Engineering; Indian Institute of Technology Kharagpur; Kharagpur West Bengal India
| | - Suman Chakraborty
- Department of Mechanical Engineering; Indian Institute of Technology Kharagpur; Kharagpur West Bengal India
| |
Collapse
|
35
|
Das D, Phan DT, Zhao Y, Kang Y, Chan V, Yang C. A multi-module microfluidic platform for continuous pre-concentration of water-soluble ions and separation of oil droplets from oil-in-water (O/W) emulsions using a DC-biased AC electrokinetic technique. Electrophoresis 2017; 38:645-652. [DOI: 10.1002/elps.201600477] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 12/02/2016] [Accepted: 12/03/2016] [Indexed: 11/06/2022]
Affiliation(s)
- Dhiman Das
- School of Chemical and Biomedical Engineering; Nanyang Technological University; Singapore
| | - Dinh-Tuan Phan
- School of Mechanical and Aerospace Engineering; Nanyang Technological University; Singapore
| | - Yugang Zhao
- School of Mechanical and Aerospace Engineering; Nanyang Technological University; Singapore
| | - Yuejun Kang
- Faculty of Materials and Energy; Southwest University; Chongqing P. R. China
| | - Vincent Chan
- Department of Chemical Engineering; Khalifa University; Abu Dhabi Campus United Arab Emirates
| | - Chun Yang
- School of Mechanical and Aerospace Engineering; Nanyang Technological University; Singapore
| |
Collapse
|
36
|
Wu Y, Ren Y, Tao Y, Hou L, Hu Q, Jiang H. A novel micromixer based on the alternating current-flow field effect transistor. LAB ON A CHIP 2016; 17:186-197. [PMID: 27934980 DOI: 10.1039/c6lc01346e] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Induced-charge electroosmosis (ICEO) phenomena have been attracting considerable attention as a means for pumping and mixing in microfluidic systems with the advantage of simple structures and low-energy consumption. We propose the first effort to exploit a fixed-potential ICEO flow around a floating electrode for microfluidic mixing. In analogy with the field effect transistor (FET) in microelectronics, the floating electrode act as a "gate" electrode for generating asymmetric ICEO flow and thus the device is called an AC-flow FET (AC-FFET). We take advantage of a tandem electrode configuration containing two biased center metal strips arranged in sequence at the bottom of the channel to generate asymmetric vortexes. The current device is manufactured on low-cost glass substrates via an easy and reliable process. Mixing experiments were conducted in the proposed device and the comparison between simulation and experimental results was also carried out, which indicates that the micromixer permits an efficient mixing effect. The mixing performance can be further enhanced by the application of a suitable phase difference between the driving electrode and the gate electrode or a square wave signal. Finally, we performed a critical analysis of the proposed micromixer in comparison with different mixer designs using a comparative mixing index (CMI). The novel methods put forward here offer a simple solution to mixing issues in microfluidic systems.
Collapse
Affiliation(s)
- Yupan Wu
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang, 150001 PR China.
| | - Yukun Ren
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang, 150001 PR China. and State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang, 150001 PR China
| | - Ye Tao
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang, 150001 PR China.
| | - Likai Hou
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang, 150001 PR China.
| | - Qingming Hu
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang, 150001 PR China.
| | - Hongyuan Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang, 150001 PR China. and State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang, 150001 PR China
| |
Collapse
|
37
|
Lang Q, Ren Y, Hobson D, Tao Y, Hou L, Jia Y, Hu Q, Liu J, Zhao X, Jiang H. In-plane microvortices micromixer-based AC electrothermal for testing drug induced death of tumor cells. BIOMICROFLUIDICS 2016; 10:064102. [PMID: 27917250 PMCID: PMC5106430 DOI: 10.1063/1.4967455] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Accepted: 10/28/2016] [Indexed: 05/20/2023]
Abstract
Herein, we first describe a perfusion chip integrated with an AC electrothermal (ACET) micromixer to supply a uniform drug concentration to tumor cells. The in-plane fluid microvortices for mixing were generated by six pairs of reconstructed novel ACET asymmetric electrodes. To enhance the mixing efficiency, the novel ACET electrodes with rotating angles of 0°, 30°, and 60° were investigated. The asymmetric electrodes with a rotating angle of 60° exhibited the highest mixing efficiency by both simulated and experimental results. The length of the mixing area is 7 mm, and the mixing efficiency is 89.12% (approximate complete mixing) at a voltage of 3 V and a frequency of 500 kHz. The applicability of our micromixer with electrodes rotating at 60° was demonstrated by the drug (tamoxifen) test of human breast cancer cells (MCF-7) for five days, which implies that our ACET in-plane microvortices micromixer has great potential for the application of drug induced rapid death of tumor cells and mixing of biomaterials in organs-on-a-chip systems.
Collapse
Affiliation(s)
| | | | - Divia Hobson
- Interdisciplinary division of Biomedical Engineering, the Hong King Polytechnique University , Hunghom, Hong Kong, China
| | - Ye Tao
- School of Mechatronics Engineering, Harbin Institute of Technology , Harbin 150001, China
| | - Likai Hou
- School of Mechatronics Engineering, Harbin Institute of Technology , Harbin 150001, China
| | - Yankai Jia
- School of Mechatronics Engineering, Harbin Institute of Technology , Harbin 150001, China
| | - Qingming Hu
- School of Mechatronics Engineering, Harbin Institute of Technology , Harbin 150001, China
| | - Jiangwei Liu
- School of Mechatronics Engineering, Harbin Institute of Technology , Harbin 150001, China
| | - Xin Zhao
- Interdisciplinary division of Biomedical Engineering, the Hong King Polytechnique University , Hunghom, Hong Kong, China
| | | |
Collapse
|
38
|
Wu Y, Ren Y, Jiang H. Enhanced model-based design of a high-throughput three dimensional micromixer driven by alternating-current electrothermal flow. Electrophoresis 2016; 38:258-269. [DOI: 10.1002/elps.201600106] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 06/28/2016] [Accepted: 06/29/2016] [Indexed: 01/13/2023]
Affiliation(s)
- Yupan Wu
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin P. R. China
| | - Yukun Ren
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin P. R. China
| | - Hongyuan Jiang
- School of Mechatronics Engineering; Harbin Institute of Technology; Harbin P. R. China
| |
Collapse
|
39
|
Abstract
As the future of health care diagnostics moves toward more portable and personalized techniques, there is immense potential to harness the power of electrical signals for biological sensing and diagnostic applications at the point of care. Electrical biochips can be used to both manipulate and sense biological entities, as they can have several inherent advantages, including on-chip sample preparation, label-free detection, reduced cost and complexity, decreased sample volumes, increased portability, and large-scale multiplexing. The advantages of fully integrated electrical biochip platforms are particularly attractive for point-of-care systems. This review summarizes these electrical lab-on-a-chip technologies and highlights opportunities to accelerate the transition from academic publications to commercial success.
Collapse
Affiliation(s)
- Bobby Reddy
- Department of Electrical and Computer Engineering,
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana–Champaign, Urbana, Illinois 61801
| | - Eric Salm
- Department of Bioengineering, and
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana–Champaign, Urbana, Illinois 61801
| | - Rashid Bashir
- Department of Electrical and Computer Engineering,
- Department of Bioengineering, and
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana–Champaign, Urbana, Illinois 61801
| |
Collapse
|
40
|
Lu Y, Ren Q, Liu T, Leung SL, Gau V, Liao JC, Chan CL, Wong PK. Long-range electrothermal fluid motion in microfluidic systems. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER 2016; 98:341-349. [PMID: 27127306 PMCID: PMC4843167 DOI: 10.1016/j.ijheatmasstransfer.2016.03.034] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
AC electrothermal flow (ACEF) is the fluid motion created as a result of Joule heating induced temperature gradients. ACEF is capable of performing major microfluidic operations, such as pumping, mixing, concentration, separation and assay enhancement, and is effective in biological samples with a wide range of electrical conductivity. Here, we report long-range fluid motion induced by ACEF, which creates centimeter-scale vortices. The long-range fluid motion displays a strong voltage dependence and is suppressed in microchannels with a characteristic length below ~300 μm. An extended computational model of ACEF, which considers the effects of the density gradient and temperature-dependent parameters, is developed and compared experimentally by particle image velocimetry. The model captures the essence of ACEF in a wide range of channel dimensions and operating conditions. The combined experimental and computational study reveals the essential roles of buoyancy, temperature rise, and associated changes in material properties in the formation of the long-range fluid motion. Our results provide critical information for the design and modeling of ACEF based microfluidic systems toward various bioanalytical applications.
Collapse
Affiliation(s)
- Yi Lu
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
- Departments of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802 USA
| | - Qinlong Ren
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
| | - Tingting Liu
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
| | - Siu Ling Leung
- Departments of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802 USA
- College of Medicine, The University of Arizona, Tucson, 85724, USA
| | - Vincent Gau
- GeneFluidics Inc., Irwindale, California, 91010, USA
| | - Joseph C. Liao
- Department of Urology, Stanford University, Stanford, California, 94305, USA
| | - Cho Lik Chan
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
| | - Pak Kin Wong
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, Arizona, 85721, USA
- Departments of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802 USA
- Departments of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802 USA
- Department of Surgery, Milton S. Hershey Medical Center, The Pennsylvania State University, Hershey, PA 17033 USA
| |
Collapse
|
41
|
Impacts of electrical parameters on the electroformation of giant vesicles on ITO glass chips. Colloids Surf B Biointerfaces 2016; 140:560-566. [DOI: 10.1016/j.colsurfb.2015.11.020] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Revised: 11/06/2015] [Accepted: 11/10/2015] [Indexed: 11/20/2022]
|
42
|
Ward K, Fan ZH. Mixing in microfluidic devices and enhancement methods. JOURNAL OF MICROMECHANICS AND MICROENGINEERING : STRUCTURES, DEVICES, AND SYSTEMS 2015; 25:094001. [PMID: 26549938 PMCID: PMC4634658 DOI: 10.1088/0960-1317/25/9/094001] [Citation(s) in RCA: 158] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Mixing in microfluidic devices presents a challenge due to laminar flows in microchannels, which result from low Reynolds numbers determined by the channel's hydraulic diameter, flow velocity, and solution's kinetic viscosity. To address this challenge, novel methods of mixing enhancement within microfluidic devices have been explored for a variety of applications. Passive mixing methods have been created, including those using ridges or slanted wells within the microchannels, as well as their variations with improved performance by varying geometry and patterns, by changing the properties of channel surfaces, and by optimization via simulations. In addition, active mixing methods including microstirrers, acoustic mixers, and flow pulsation have been investigated and integrated into microfluidic devices to enhance mixing in a more controllable manner. In general, passive mixers are easy to integrate, but difficult to control externally by users after fabrication. Active mixers usually take efforts to integrate within a device and they require external components (e.g. power sources) to operate. However, they can be controlled by users to a certain degree for tuned mixing. In this article, we provide a general overview of a number of passive and active mixers, discuss their advantages and disadvantages, and make suggestions on choosing a mixing method for a specific need as well as advocate possible integration of key elements of passive and active mixers to harness the advantages of both types.
Collapse
Affiliation(s)
- Kevin Ward
- Department of Chemical Engineering, University of Florida, Gainesville, Florida 32611-2023, USA
| | - Z Hugh Fan
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611–6250, USA
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611–6131, USA
- Department of Chemistry, University of Florida, Gainesville, FL 32611–7200, USA
| |
Collapse
|
43
|
Lu Y, Liu T, Lamanda AC, Sin MLY, Gau V, Liao JC, Wong PK. AC Electrokinetics of Physiological Fluids for Biomedical Applications. ACTA ACUST UNITED AC 2014; 20:611-20. [PMID: 25487557 DOI: 10.1177/2211068214560904] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Indexed: 12/13/2022]
Abstract
Alternating current (AC) electrokinetics is a collection of processes for manipulating bulk fluid mass and embedded objects with AC electric fields. The ability of AC electrokinetics to implement the major microfluidic operations, such as pumping, mixing, concentration, and separation, makes it possible to develop integrated systems for clinical diagnostics in nontraditional health care settings. The high conductivity of physiological fluids presents new challenges and opportunities for AC electrokinetics-based diagnostic systems. In this review, AC electrokinetic phenomena in conductive physiological fluids are described followed by a review of the basic microfluidic operations and the recent biomedical applications of AC electrokinetics. The future prospects of AC electrokinetics for clinical diagnostics are presented.
Collapse
Affiliation(s)
- Yi Lu
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ, USA
| | - Tingting Liu
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ, USA
| | - Ariana C Lamanda
- Biomedical Engineering, The University of Arizona, Tucson, AZ, USA
| | - Mandy L Y Sin
- Department of Urology, Stanford University, Stanford, CA, USA Veterans Affairs Palo Alto Health Care System, Palo Alto, CA, USA
| | | | - Joseph C Liao
- Department of Urology, Stanford University, Stanford, CA, USA Veterans Affairs Palo Alto Health Care System, Palo Alto, CA, USA
| | - Pak Kin Wong
- Department of Aerospace and Mechanical Engineering, The University of Arizona, Tucson, AZ, USA Biomedical Engineering, The University of Arizona, Tucson, AZ, USA
| |
Collapse
|
44
|
Salamanzadeh A, Davalos RV. Electrokinetics and Rare-Cell Detection. MICROFLUIDICS IN DETECTION SCIENCE 2014. [DOI: 10.1039/9781849737609-00061] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Lab-on-a-chip devices perform functions which are not feasible or difficult to achieve with macroscale devices. Importantly, isolating and enriching rare cells is key in health and environmental applications, such as detecting circulating tumor cells from body fluid biopsies, or pathogens from water. Within a microdevice, the dominant mechanical force on a suspended particle is the drag force as it flows through the fluid. Electrokinetic forces such as dielectrophoresis - the motion of a particle due to its polarization in the presence of a non-uniform electric field - may also be applied to manipulate particles. For instance, separation of particles can be achieved using a combination of drag and dielectrophoretic forces to precisely manipulate a particle. Understanding the interaction of electrokinetic forces, particles, and fluid flow is critical for engineering novel microsystems used for cell sorting. Determining this interaction is even more complicated when dealing with bioparticles, especially cells, due to their intrinsic complex biological properties which influence their electrical and mechanical behaviors. In order to design novel and more practical microdevices for medical, biological, and chemical applications, it is essential to have a comprehensive understanding of the mechanics of particle-fluid interaction and the dynamics of particle movement. This chapter will describe the role of electrokinetic techniques in rare cell detection and the behavior of electrokinetic microsystems.
Collapse
|
45
|
Huang YH, Chang JS, Chao SD, Wu KC, Huang LS. Improving the binding efficiency of quartz crystal microbalance biosensors by applying the electrothermal effect. BIOMICROFLUIDICS 2014; 8:054116. [PMID: 25538808 PMCID: PMC4241767 DOI: 10.1063/1.4898633] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2014] [Accepted: 10/06/2014] [Indexed: 05/06/2023]
Abstract
A quartz crystal microbalance (QCM) serving as a biosensor to detect the target biomolecules (analytes) often suffers from the time consuming process, especially in the case of diffusion-limited reaction. In this experimental work, we modify the reaction chamber of a conventional QCM by integrating into the multi-microelectrodes to produce electrothermal vortex flow which can efficiently drive the analytes moving toward the sensor surface, where the analytes were captured by the immobilized ligands. The microelectrodes are placed on the top surface of the chamber opposite to the sensor, which is located on the bottom of the chamber. Besides, the height of reaction chamber is reduced to assure that the suspended analytes in the fluid can be effectively drived to the sensor surface by induced electrothermal vortex flow, and also the sample costs are saved. A series of frequency shift measurements associated with the adding mass due to the specific binding of the analytes in the fluid flow and the immobilized ligands on the QCM sensor surface are performed with or without applying electrothermal effect (ETE). The experimental results show that electrothermal vortex flow does effectively accelerate the specific binding and make the frequency shift measurement more sensible. In addition, the images of the binding surfaces of the sensors with or without applying electrothermal effect are taken through the scanning electron microscopy. By comparing the images, it also clearly indicates that ETE does raise the specific binding of the analytes and ligands and efficiently improves the performance of the QCM sensor.
Collapse
Affiliation(s)
- Yao-Hung Huang
- Institute of Applied Mechanics, National Taiwan University , Taipei, Taiwan
| | - Jeng-Shian Chang
- Institute of Applied Mechanics, National Taiwan University , Taipei, Taiwan
| | - Sheng D Chao
- Institute of Applied Mechanics, National Taiwan University , Taipei, Taiwan
| | - Kuang-Chong Wu
- Institute of Applied Mechanics, National Taiwan University , Taipei, Taiwan
| | - Long-Sun Huang
- Institute of Applied Mechanics, National Taiwan University , Taipei, Taiwan
| |
Collapse
|
46
|
Nama N, Huang PH, Huang TJ, Costanzo F. Investigation of acoustic streaming patterns around oscillating sharp edges. LAB ON A CHIP 2014; 14:2824-36. [PMID: 24903475 PMCID: PMC4096312 DOI: 10.1039/c4lc00191e] [Citation(s) in RCA: 85] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Oscillating sharp edges have been employed to achieve rapid and homogeneous mixing in microchannels using acoustic streaming. Here, we used a perturbation approach to study the flow around oscillating sharp edges in a microchannel. This work extends prior experimental studies to numerically characterize the effect of various parameters on the acoustically induced flow. Our numerical results match well with the experimental results. We investigated multiple device parameters such as the tip angle, oscillation amplitude, and channel dimensions. Our results indicate that, due to the inherent nonlinearity of acoustic streaming, the channel dimensions could significantly impact the flow patterns and device performance.
Collapse
Affiliation(s)
- Nitesh Nama
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
| | - Po-Hsun Huang
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
| | - Tony Jun Huang
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
- Department of Bioengineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Francesco Costanzo
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA
- Center for Neural Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| |
Collapse
|
47
|
Huang PH, Xie Y, Ahmed D, Rufo J, Nama N, Chen Y, Chan CY, Huang TJ. An acoustofluidic micromixer based on oscillating sidewall sharp-edges. LAB ON A CHIP 2013; 13:3847-52. [PMID: 23896797 PMCID: PMC3988907 DOI: 10.1039/c3lc50568e] [Citation(s) in RCA: 140] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Rapid and homogeneous mixing inside a microfluidic channel is demonstrated via the acoustic streaming phenomenon induced by the oscillation of sidewall sharp-edges. By optimizing the design of the sharp-edges, excellent mixing performance and fast mixing speed can be achieved in a simple device, making our sharp-edge-based acoustic micromixer a promising candidate for a wide variety of applications.
Collapse
Affiliation(s)
- Po-Hsun Huang
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA 16802, USA.
| | | | | | | | | | | | | | | |
Collapse
|
48
|
Washe AP, Lozano P, Bejarano D, Katakis I. Eletrochemically actuated stop-go valves for capillary force-operated diagnostic microsystems. Chemphyschem 2013; 14:2164-73. [PMID: 23592401 DOI: 10.1002/cphc.201300042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Indexed: 11/10/2022]
Abstract
Lateral-flow immunosensing devices continue to be the most successful commercial realization of analytical microdevices. They owe their success to their simplicity, which significantly depends on the capillary-driven flow and versatile technological platform that lends itself to fast and low-cost product development. To compete with such a convenient product, microsystems can benefit from simple-to-operate fluid manipulation. We show that the capillary-driven flow in microchannels can be manipulated with electrochemically activated valves with no moving parts. These valves consist of screen-printed electrode pairs that are transversal to the flow. One of the electrodes is solvent-etched to produce a superhydrophobic surface that provides passive stopping and facilitates low-voltage (~1 V) actuation of the flow via electrowetting. The operation of such valves in the stop-go mode, with a response time between 2 and 45 sec depending on the type and concentration of salt, is demonstrated. Mechanistic investigations indicated that the response depends on at least three phenomena that contribute to electrocapillarity: the electrochemical double-layer capacitance, specific counterion adsorption, and possible electrohydrodynamic effects.
Collapse
Affiliation(s)
- Alemayehu P Washe
- Bioengineering and Bioelectrochemistry Group, Department of Chemical Engineering, Universitat Rovira i Virgili, Avinguda Països Catalans, 26, 43007, Tarragona, Spain
| | | | | | | |
Collapse
|
49
|
Deng Y, Liu Z, Zhang P, Liu Y, Gao Q, Wu Y. A flexible layout design method for passive micromixers. Biomed Microdevices 2013; 14:929-45. [PMID: 22736305 DOI: 10.1007/s10544-012-9672-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
This paper discusses a flexible layout design method of passive micromixers based on the topology optimization of fluidic flows. Being different from the trial and error method, this method obtains the detailed layout of a passive micromixer according to the desired mixing performance by solving a topology optimization problem. Therefore, the dependence on the experience of the designer is weaken, when this method is used to design a passive micromixer with acceptable mixing performance. Several design disciplines for the passive micromixers are considered to demonstrate the flexibility of the layout design method for passive micromixers. These design disciplines include the approximation of the real 3D micromixer, the manufacturing feasibility, the spacial periodic design, and effects of the Péclet number and Reynolds number on the designs obtained by this layout design method. The capability of this design method is validated by several comparisons performed between the obtained layouts and the optimized designs in the recently published literatures, where the values of the mixing measurement is improved up to 40.4% for one cycle of the micromixer.
Collapse
Affiliation(s)
- Yongbo Deng
- Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, 130033, Changchun, China
| | | | | | | | | | | |
Collapse
|
50
|
Numerical study of a novel induced-charge electrokinetic micro-mixer. Anal Chim Acta 2013; 763:28-37. [DOI: 10.1016/j.aca.2012.12.010] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2012] [Revised: 09/27/2012] [Accepted: 12/04/2012] [Indexed: 11/23/2022]
|