1
|
Zhao H, Zhang Y, Hua D. A Review of Research Progress in Microfluidic Bioseparation and Bioassay. MICROMACHINES 2024; 15:893. [PMID: 39064404 PMCID: PMC11278910 DOI: 10.3390/mi15070893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 07/03/2024] [Accepted: 07/05/2024] [Indexed: 07/28/2024]
Abstract
With the rapid development of biotechnology, the importance of microfluidic bioseparation and bioassay in biomedicine, clinical diagnosis, and other fields has become increasingly prominent. Microfluidic technology, with its significant advantages of high throughput, automated operation, and low sample consumption, has brought new breakthroughs in the field of biological separation and bioassay. In this paper, the latest research progress in microfluidic technology in the field of bioseparation and bioassay is reviewed. Then, we focus on the methods of bioseparation including active separation, passive separation, and hybrid separation. At the same time, the latest research results of our group in particle separation are introduced. Finally, some application examples or methods for bioassay after particle separation are listed, and the current challenges and future prospects of bioseparation and bioassay are discussed.
Collapse
Affiliation(s)
| | | | - Dengxin Hua
- Center for Lidar Remote Sensing Research, School of Mechanical and Precision Instrument Engineering, Xi’an University of Technology, Xi’an 710048, China.; (H.Z.); (Y.Z.)
| |
Collapse
|
2
|
Öztürk Ö, Servantie J. Statics and dynamics of polymeric droplets on chemically homogeneous and heterogeneous substrates. Phys Rev E 2019; 100:023113. [PMID: 31574604 DOI: 10.1103/physreve.100.023113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Indexed: 06/10/2023]
Abstract
We present a molecular dynamics study of the motion of cylindrical polymer droplets on striped surfaces. We first consider the equilibrium properties of droplets on different surfaces, we show that for small stripes the Cassie-Baxter equation gives a good approximation of the equilibrium contact angle. As the stripe width becomes nonnegligible compared to the dimension of the droplet, it has to deform significantly to minimize its free energy; this results in a smaller value of the contact angle than the continuum model predicts. We then evaluate the slip length and thus the damping coefficient as a function of the stripe width. For very small stripes, the heterogeneous surface behaves as an effective surface, with the same damping as a homogeneous surface with the same contact angle. However, as the stripe width increases, damping at the surface increases until reaching a plateau. Afterwards, we study the dynamics of droplets under a bulk force. We show that if the stripes are large enough the droplets are pinned until a critical force. The critical force increases linearly with stripe width. For large enough forces, the average velocity increases linearly with the force, we show that it can then be predicted by a model depending only on droplet size, contact angle, viscosity, and slip length. We show that the velocity of the droplet varies sinusoidally as a function of its position on the substrate. However, for bulk forces just above the depinning force we observe a characteristic stick-slip motion, with successive pinnings and depinnings.
Collapse
Affiliation(s)
- Ö Öztürk
- Department of Physics, Istanbul Technical University, Maslak 34469, Istanbul, Turkey
| | - J Servantie
- Department of Physics, Istanbul Technical University, Maslak 34469, Istanbul, Turkey
| |
Collapse
|
3
|
Muhamed I, Sproul EP, Ligler FS, Brown AC. Fibrin Nanoparticles Coupled with Keratinocyte Growth Factor Enhance the Dermal Wound-Healing Rate. ACS APPLIED MATERIALS & INTERFACES 2019; 11:3771-3780. [PMID: 30604611 DOI: 10.1021/acsami.8b21056] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Expediting the wound-healing process is critical for patients chronically ill from nonhealing wounds and diseases such as hemophilia or diabetes or who have suffered trauma including easily infected open wounds. FDA-approved external tissue sealants include the topical application of fibrin gels, which can be 500 times denser than natural fibrin clots. With lower clot porosity and higher polymerization rates than physiologically formed fibrin clots, the commercial gels quickly stop blood loss but impede the later clot degradation kinetics and thus retard tissue-healing rates. The fibrin nanoparticles (FBNs) described here are constructed from physiologically relevant fibrin concentrations that support new tissue and dermal wound scaffold formation when coupled with growth factors. The FBNs, synthesized in a microfluidic droplet generator, support cell adhesion and traction generation, and when coupled to keratinocyte growth factor (KGF), support cell migration and in vivo wound healing. The FBN-KGF particles enhance cell migration in vitro greater than FBN alone or free KGF and also improve healing outcomes in a murine full thickness injury model compared to saline, bulk fibrin sealant, free KGF, or bulk fibrin mixed with KGF treatments. Furthermore, FBN can be potentially administered with other tissue-healing factors and inflammatory mediators to improve wound-healing outcomes.
Collapse
Affiliation(s)
- Ismaeel Muhamed
- Joint Department of Biomedical Engineering , North Carolina State University and University of North Carolina at Chapel Hill , Raleigh 27695 , North Carolina , United States
- Comparative Medicine Institute , North Carolina State University , Raleigh 27695 , North Carolina , United States
| | - Erin P Sproul
- Joint Department of Biomedical Engineering , North Carolina State University and University of North Carolina at Chapel Hill , Raleigh 27695 , North Carolina , United States
- Comparative Medicine Institute , North Carolina State University , Raleigh 27695 , North Carolina , United States
| | - Frances S Ligler
- Joint Department of Biomedical Engineering , North Carolina State University and University of North Carolina at Chapel Hill , Raleigh 27695 , North Carolina , United States
- Comparative Medicine Institute , North Carolina State University , Raleigh 27695 , North Carolina , United States
| | - Ashley C Brown
- Joint Department of Biomedical Engineering , North Carolina State University and University of North Carolina at Chapel Hill , Raleigh 27695 , North Carolina , United States
- Comparative Medicine Institute , North Carolina State University , Raleigh 27695 , North Carolina , United States
| |
Collapse
|
4
|
Droplet Breakup in Expansion-contraction Microchannels. Sci Rep 2016; 6:21527. [PMID: 26899018 PMCID: PMC4761913 DOI: 10.1038/srep21527] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Accepted: 01/26/2016] [Indexed: 11/28/2022] Open
Abstract
We investigate the influences of expansion-contraction microchannels on droplet breakup in capillary microfluidic devices. With variations in channel dimension, local shear stresses at the injection nozzle and focusing orifice vary, significantly impacting flow behavior including droplet breakup locations and breakup modes. We observe transition of droplet breakup location from focusing orifice to injection nozzle, and three distinct types of recently-reported tip-multi-breaking modes. By balancing local shear stresses and interfacial tension effects, we determine the critical condition for breakup location transition, and characterize the tip-multi-breaking mode quantitatively. In addition, we identify the mechanism responsible for the periodic oscillation of inner fluid tip in tip-multi-breaking mode. Our results offer fundamental understanding of two-phase flow behaviors in expansion-contraction microstructures, and would benefit droplet generation, manipulation and design of microfluidic devices.
Collapse
|
5
|
Ma S, Sherwood JM, Huck WTS, Balabani S. On the flow topology inside droplets moving in rectangular microchannels. LAB ON A CHIP 2014; 14:3611-3620. [PMID: 25072660 DOI: 10.1039/c4lc00671b] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The flow topology in moving microdroplets has a significant impact on the behaviour of encapsulated objects and hence on applications of the technology. This study reports on a systematic investigation of the flow field inside droplets moving in a rectangular microchannel, by means of micro-particle image velocimetry (μPIV). Various water/oil (w/o) fluid mixtures were studied in order to elucidate the effects of a number of parameters such as capillary number (Ca), droplet geometry, viscosity ratio and interfacial tension. A distinct change in flow topology was observed at intermediate Ca ranging from 10(-3) to 10(-1), in surfactant-laden droplets, which was attributed primarily to the viscosity ratio of the two phases rather than the Marangoni effect expected in such systems. W/o droplet systems of lower inner-to-outer viscosity ratios tend to exhibit the well-known flow pattern characterised by a parabola-like profile in the droplet bulk-volume, surrounded by two counter rotating recirculation zones on either side of the droplet axis. As the viscosity ratio between the two phases is increased, the flow pattern becomes more uniform, exhibiting low velocities in the droplet bulk-volume and higher-reversed velocities along the w/o interface. The Ca and droplet geometry had no effect on the observed flow topology change. The study highlights the complex, three-dimensional (3D) nature of the flow inside droplets in rectangular microchannels and demonstrates the ability to control the droplet flow environment by adjusting the viscosity ratio between the two phases.
Collapse
Affiliation(s)
- Shaohua Ma
- Department of Chemistry, University of Cambridge, Cambridge, CB2 1EW, UK
| | | | | | | |
Collapse
|
6
|
Dammann C, Köster S. Dynamics of counterion-induced attraction between vimentin filaments followed in microfluidic drops. LAB ON A CHIP 2014; 14:2681-7. [PMID: 24834442 DOI: 10.1039/c3lc51418h] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Intermediate filaments (IFs) are fiber-forming proteins and part of the cytoskeleton of eukaryotes. In vitro the network formation of purified IF systems is mediated, for example, by the interaction with multivalent ions. The understanding of these interaction mechanisms increases the knowledge of the cytoskeleton on a fundamental level. Here, we employ time-lapse fluorescence microscopy to directly image the evolution of network formation of vimentin IFs upon addition of divalent ions. We are thus able to follow the process starting a few seconds after the first encounter of free filaments and ions up to several minutes when the networks are in equilibrium. The local protein density in the compacted networks can reach a factor of 45 higher than the original solution concentration. The competition between mono- and divalent ion condensation onto the protein explains our observations and reveals the polyelectrolyte nature of vimentin as a reason for the protein attraction in the presence of small cations. The method for time-lapse studies in microfluidic drops presented here can be generalized to other dynamic systems.
Collapse
Affiliation(s)
- Christian Dammann
- Institute for X-Ray Physics, Georg-August-Universität Göttingen, Germany and Center for Nanoscale Microscopy and Molecular Physiology of the Brain (CNMPB), Friedrich-Hund-Platz 1, 37077 Göttingen, Germany.
| | | |
Collapse
|
7
|
Abstract
In the present paper, we review and discuss current developments and challenges in the field of droplet-based microfluidics. This discussion includes an assessment of the basic fluid dynamics of segmented flows, material requirements, fundamental unit operations and how integration of functional components can be applied to specific biological problems.
Collapse
|
8
|
Dammann C, Nöding B, Köster S. Vimentin networks at tunable ion-concentration in microfluidic drops. BIOMICROFLUIDICS 2012; 6:22009-2200910. [PMID: 22655012 PMCID: PMC3360716 DOI: 10.1063/1.4705103] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Accepted: 04/04/2012] [Indexed: 05/11/2023]
Abstract
The structure and function of biological systems, for example, cells and proteins, depend strongly on their chemical environment. To investigate such dependence, we design a polydimethylsiloxane-based microfluidic device to encapsulate biological systems in picoliter-sized drops. The content of each individual drop is tuned in a defined manner. As a key feature of our method, the individual chemical composition is determined and related to the drop content. In our case, the drop content is imaged using microscopy methods, while the drops are immobilized to allow for long-time studies. As an application of our device, we study the influence of divalent ions on vimentin intermediate filament networks in a quantitative way by tuning the magnesium concentration from drop to drop. This way we are able to directly image the effect of magnesium on the fluorescently tagged protein in a few hundreds of drops. Our study shows that with increasing magnesium concentration in the drops, the compaction of the networks becomes more pronounced. The degree of compaction is characterized by different morphologies; freely fluctuating networks are observed at comparatively low magnesium concentrations of 5-10 mM, while with increasing magnesium concentration reaching 16 mM they develop into fully aggregated networks. Our approach demonstrates how a systematic study of interactions in biological systems can benefit from the exceptional controllability of microfluidic methods.
Collapse
Affiliation(s)
- Christian Dammann
- Institute for X-Ray Physics and Courant Research Centre "Nano-Spectroscopy and X-Ray Imaging," Georg-August-Universität Göttingen, 37077 Göttingen, Germany
| | | | | |
Collapse
|
9
|
van Geffen M, van Heerde WL. Global haemostasis assays, from bench to bedside. Thromb Res 2012; 129:681-7. [PMID: 22221936 DOI: 10.1016/j.thromres.2011.12.006] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2011] [Revised: 12/02/2011] [Accepted: 12/04/2011] [Indexed: 10/14/2022]
Abstract
Bleeding and thrombosis are the ultimate clinical outcomes of aberrations in the haemostatic process. Haemostasis prevents excessive blood loss due to the effort of various compartments like the vasculature, blood cells, coagulation and fibrinolysis. The complexity of all processes involved makes the diagnosis of aberrations difficult, cumbersome and expensive. A single assay to detect any factor disturbing this haemostatic balance with high sensitivity and specificity would be of great value, especially if the outcome of this assay correlates well with clinical outcome. Despite years of research, such an assay is not yet available; however, some interesting candidates are under development and combine the effects of various compartments. This review describes the development of global haemostasis assays and summarizes the current state of the art of these haemostasis assays covering thrombin and plasmin generation, turbidity and thromboelastography/thromboelastometry. Finally, we discuss the applicability of global assays in clinical practice and we provide a future perspective on the ongoing development of automation and miniaturisation as it is our belief that these developments will benefit the standardization of global haemostasis assays.
Collapse
Affiliation(s)
- Mark van Geffen
- Laboratory of Haematology, department of Laboratory Medicine, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands
| | | |
Collapse
|
10
|
Seemann R, Brinkmann M, Pfohl T, Herminghaus S. Droplet based microfluidics. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2012; 75:016601. [PMID: 22790308 DOI: 10.1088/0034-4885/75/1/016601] [Citation(s) in RCA: 488] [Impact Index Per Article: 40.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Droplet based microfluidics is a rapidly growing interdisciplinary field of research combining soft matter physics, biochemistry and microsystems engineering. Its applications range from fast analytical systems or the synthesis of advanced materials to protein crystallization and biological assays for living cells. Precise control of droplet volumes and reliable manipulation of individual droplets such as coalescence, mixing of their contents, and sorting in combination with fast analysis tools allow us to perform chemical reactions inside the droplets under defined conditions. In this paper, we will review available drop generation and manipulation techniques. The main focus of this review is not to be comprehensive and explain all techniques in great detail but to identify and shed light on similarities and underlying physical principles. Since geometry and wetting properties of the microfluidic channels are crucial factors for droplet generation, we also briefly describe typical device fabrication methods in droplet based microfluidics. Examples of applications and reaction schemes which rely on the discussed manipulation techniques are also presented, such as the fabrication of special materials and biophysical experiments.
Collapse
Affiliation(s)
- Ralf Seemann
- Experimental Physics, Saarland University, D-66123 Saarbrücken, Germany.
| | | | | | | |
Collapse
|
11
|
Priest C, Zhou J, Sedev R, Ralston J, Aota A, Mawatari K, Kitamori T. Microfluidic extraction of copper from particle-laden solutions. ACTA ACUST UNITED AC 2011. [DOI: 10.1016/j.minpro.2010.11.005] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
12
|
Brennich ME, Nolting JF, Dammann C, Nöding B, Bauch S, Herrmann H, Pfohl T, Köster S. Dynamics of intermediate filament assembly followed in micro-flow by small angle X-ray scattering. LAB ON A CHIP 2011; 11:708-716. [PMID: 21212871 DOI: 10.1039/c0lc00319k] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The assembly of intermediate filaments (IFs) is a complex process that can be recapitulated through a series of distinct steps in vitro. The combination of microfluidics and small angle X-ray scattering (SAXS) provides a powerful tool to investigate the kinetics of this process on the relevant timescales. Microfluidic mixers based on the principle of hydrodynamic focusing allow for precise control of the mixing of proteins and smaller reagents like ions. Here, we present a multi-layer device that prevents proteins from adsorbing to the channel walls by engulfing the protein jet with a fluid layer of buffer. To ensure compatibility with SAXS, the device is fabricated from UV-curable adhesive (NOA 81). To demonstrate the successful prevention of contact between the protein jet and the channel walls we measure the distribution of a fluorescent dye in the device by confocal microscopy at various flow speeds and compare the results to finite element method (FEM) simulations. The prevention of contact enables the investigation of the assembly of IFs in flow by gradually increasing the salt concentration in the protein jet. The diffusion of salt into the jet can be determined by FEM simulations. SAXS data are collected at different positions in the jet, corresponding to different salt concentrations, and they reveal distinct differences between the earliest assembly states. We find that the mean square radius of gyration perpendicular to the filament axis increases from 13 nm(2) to 58 nm(2) upon assembly. Thereby we provide dynamic structural data of a complex assembly process that was amenable up to now only by microscopic techniques.
Collapse
Affiliation(s)
- Martha Elisabeth Brennich
- Courant Research Centre Nano-Spectroscopy and X-ray Imaging, Georg-August-Universität Göttingen, Göttingen, Germany
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Chokkalingam V, Weidenhof B, Krämer M, Maier WF, Herminghaus S, Seemann R. Optimized droplet-based microfluidics scheme for sol-gel reactions. LAB ON A CHIP 2010; 10:1700-5. [PMID: 20405061 DOI: 10.1039/b926976b] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
A droplet-based microfluidic reaction scheme is developed where the chemical reactants are dispensed with precise volume control into pairs of droplets. The reaction is activated by coalescing droplet pairs and fast mixing inside the coalesced droplets. Furthermore, the pre-processing of the chemical products is included in the microfluidic device. This reaction scheme allows the performing of precisely volume controlled reactions and long operation times without any clogging even if precipitates or sticky gels are formed during the reaction. Using this approach and optimizing the reaction parameters, we generate mesoporous silica microspheres from a rapid gelation optimized sol-gel synthesis route. The produced silica particles have a superior surface area of 820 m(2) g(-1) and a narrow pore radius distribution of around 2.4 nm.
Collapse
|
14
|
Theberge A, Courtois F, Schaerli Y, Fischlechner M, Abell C, Hollfelder F, Huck W. Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology. Angew Chem Int Ed Engl 2010; 49:5846-68. [DOI: 10.1002/anie.200906653] [Citation(s) in RCA: 833] [Impact Index Per Article: 59.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
15
|
Chokkalingam V, Weidenhof B, Krämer M, Herminghaus S, Seemann R, Maier WF. Template-free Preparation of Mesoporous Silica Spheres through Optimized Microfluidics. Chemphyschem 2010; 11:2091-5. [DOI: 10.1002/cphc.201000188] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
16
|
Arora A, Simone G, Salieb-Beugelaar GB, Kim JT, Manz A. Latest Developments in Micro Total Analysis Systems. Anal Chem 2010; 82:4830-47. [PMID: 20462185 DOI: 10.1021/ac100969k] [Citation(s) in RCA: 372] [Impact Index Per Article: 26.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Arun Arora
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Giuseppina Simone
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Georgette B. Salieb-Beugelaar
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Jung Tae Kim
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Andreas Manz
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| |
Collapse
|