1
|
Douma C, Bowser MT. Assessing Surface Adsorption in Cyclic Olefin Copolymer Microfluidic Devices Using Two-Dimensional Nano Liquid Chromatography-Micro Free Flow Electrophoresis Separations. Anal Chem 2023; 95:18379-18387. [PMID: 38060457 PMCID: PMC10733905 DOI: 10.1021/acs.analchem.3c03014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 10/11/2023] [Accepted: 10/18/2023] [Indexed: 12/20/2023]
Abstract
Surface interactions are a concern in microscale separations, where analyte adsorption can decrease the speed, sensitivity, and resolution otherwise achieved by miniaturization. Here, we functionally characterize the surface adsorption of hot-embossed cyclic olefin copolymer (COC) micro free-flow electrophoresis (μFFE) devices using two-dimensional nLC × μFFE separations, which introduce a 3- to 5 s plug of analyte into the device and measure temporal broadening that arises from surface interactions. COC is an attractive material for microfluidic devices, but little is known about its potential for surface adsorption in applications with continuous fluid flow and temporal measurements. Adsorption was minimal for three small molecule dyes: positively charged rhodamine 123, negatively charged fluorescein, and neutral rhodamine 110. Temporal peak widths for the three dyes ranged from 3 to 7 s and did not change significantly with increasing transit distance. Moderate adsorption was observed for Chromeo P503-labeled myoglobin and cytochrome c with temporal peak widths around 20 s. Overall, the COC surface adsorption was low compared to traditional glass devices, where peak widths are on the order of minutes. Improvements in durability, long-term performance, and ease of fabrication, combined with low overall adsorption, make the COC μFFE devices a practical choice for applications involving time-resolved continuous detection.
Collapse
Affiliation(s)
- Cecilia
C. Douma
- Department of Chemistry, University
of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Michael T. Bowser
- Department of Chemistry, University
of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
2
|
LeMon MB, Douma CC, Burke GS, Bowser MT. Fabrication of µFFE Devices in COC via Hot Embossing with a 3D-Printed Master Mold. MICROMACHINES 2023; 14:1728. [PMID: 37763891 PMCID: PMC10534651 DOI: 10.3390/mi14091728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 08/19/2023] [Accepted: 08/25/2023] [Indexed: 09/29/2023]
Abstract
The fabrication of high-performance microscale devices in substrates with optimal material properties while keeping costs low and maintaining the flexibility to rapidly prototype new designs remains an ongoing challenge in the microfluidics field. To this end, we have fabricated a micro free-flow electrophoresis (µFFE) device in cyclic olefin copolymer (COC) via hot embossing using a PolyJet 3D-printed master mold. A room-temperature cyclohexane vapor bath was used to clarify the device and facilitate solvent-assisted thermal bonding to fully enclose the channels. Device profiling showed 55 µm deep channels with no detectable feature degradation due to solvent exposure. Baseline separation of fluorescein, rhodamine 110, and rhodamine 123, was achieved at 150 V. Limits of detection for these fluorophores were 2 nM, 1 nM, and 10 nM, respectively, and were comparable to previously reported values for glass and 3D-printed devices. Using PolyJet 3D printing in conjunction with hot embossing, the full design cycle, from initial design to production of fully functional COC µFFE devices, could be completed in as little as 6 days without the need for specialized clean room facilities. Replicate COC µFFE devices could be produced from an existing embossing mold in as little as two hours.
Collapse
Affiliation(s)
| | | | | | - Michael T. Bowser
- Department of Chemistry, University of Minnesota, Minneapolis, MN 55455, USA
| |
Collapse
|
3
|
Zhang A, Xu J, Li X, Lin Z, Song Y, Li X, Wang Z, Cheng Y. High-Throughput Continuous-Flow Separation in a Micro Free-Flow Electrophoresis Glass Chip Based on Laser Microfabrication. SENSORS (BASEL, SWITZERLAND) 2022; 22:1124. [PMID: 35161869 PMCID: PMC8838507 DOI: 10.3390/s22031124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 01/20/2022] [Accepted: 01/28/2022] [Indexed: 06/14/2023]
Abstract
Micro free-flow electrophoresis (μFFE) provides a rapid and straightforward route for the high-performance online separation and purification of targeted liquid samples in a mild manner. However, the facile fabrication of a μFFE device with high throughput and high stability remains a challenge due to the technical barriers of electrode integration and structural design for the removal of bubbles for conventional methods. To address this, the design and fabrication of a high-throughput μFFE chip are proposed using laser-assisted chemical etching of glass followed by electrode integration and subsequent low-temperature bonding. The careful design of the height ratio of the separation chamber and electrode channels combined with a high flow rate of buffer solution allows the efficient removal of electrolysis-generated bubbles along the deep electrode channels during continuous-flow separation. The introduction of microchannel arrays further enhances the stability of on-chip high-throughput separation. As a proof-of-concept, high-performance purification of fluorescein sodium solution with a separation purity of ~97.9% at a voltage of 250 V from the mixture sample solution of fluorescein sodium and rhodamine 6G solution is demonstrated.
Collapse
Affiliation(s)
- Aodong Zhang
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Jian Xu
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Xiaolong Li
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Zijie Lin
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Yunpeng Song
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Xin Li
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
| | - Zhenhua Wang
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
| | - Ya Cheng
- Engineering Research Center for Nanophotonics and Advanced Instrument, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (A.Z.); (Z.W.); (Y.C.)
- State Key Laboratory of Precision Spectroscopy, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China; (X.L.); (Z.L.); (Y.S.)
- XXL—The Extreme Optoelectromechanics Laboratory, School of Physics and Electronic Science, East China Normal University, Shanghai 200241, China
- State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
| |
Collapse
|
4
|
Kochmann S, Ivanov NA, Lucas KS, Krylov SN. Topino: A Graphical Tool for Quantitative Assessment of Molecular Stream Separations. Anal Chem 2021; 93:9980-9985. [PMID: 34255479 DOI: 10.1021/acs.analchem.1c01229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In molecular-stream separation (MSS), a stream of a multicomponent mixture is separated into multiple streams of individual components. Quantitative evaluation of MSS data has been a bottleneck in MSS for decades as there was no conventional way to present the data in a reproducible and uniform fashion. The roots of the problem were in the multidimensional nature of MSS data; even in the ideal case of steady-state separation, the data is three-dimensional: intensity and two spatial coordinates. We recently found a way to reduce the dimensionality via presenting the MSS data in a polar coordinate system and convoluting the data via integration of intensity along the radius axis. The result of this convolution is an angulagram, a simple 2D plot presenting integrated intensity vs angle. Not only does an angulagram simplify the visual assessment, but it also allows the determination of three quantitative parameters characterizing the quality of MSS: stream width, stream linearity, and stream deflection. Reliably converting an MSS image into an angulagram and accurately determining the stream parameters requires an advanced and user-friendly software tool. In this technical note, we introduce such a tool: the open-source software Topino available at https://github.com/Schallaven/topino. Topino is a stand-alone program with a modern graphical user interface that allows processing an MSS image in a fast (<2 min) and straightforward way. The robustness and ruggedness of Topino were confirmed by comparing the results obtained by three users. Topino removes the analytical bottleneck in MSS and will be an indispensable tool for MSS users with varying levels of experience.
Collapse
Affiliation(s)
- Sven Kochmann
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Nikita A Ivanov
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Kevin S Lucas
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Sergey N Krylov
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| |
Collapse
|
5
|
Preuss JA, Nguyen GN, Berk V, Bahnemann J. Miniaturized free-flow electrophoresis: production, optimization, and application using 3D printing technology. Electrophoresis 2020; 42:305-314. [PMID: 33128392 DOI: 10.1002/elps.202000149] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 10/22/2020] [Accepted: 10/25/2020] [Indexed: 12/11/2022]
Abstract
The increasing resolution of three-dimensional (3D) printing offers simplified access to, and development of, microfluidic devices with complex 3D structures. Therefore, this technology is increasingly used for rapid prototyping in laboratories and industry. Microfluidic free flow electrophoresis (μFFE) is a versatile tool to separate and concentrate different samples (such as DNA, proteins, and cells) to different outlets in a time range measured in mere tens of seconds and offers great potential for use in downstream processing, for example. However, the production of μFFE devices is usually rather elaborate. Many designs are based on chemical pretreatment or manual alignment for the setup. Especially for the separation chamber of a μFFE device, this is a crucial step which should be automatized. We have developed a smart 3D design of a μFFE to pave the way for a simpler production. This study presents (1) a robust and reproducible way to build up critical parts of a μFFE device based on high-resolution MultiJet 3D printing; (2) a simplified insertion of commercial polycarbonate membranes to segregate separation and electrode chambers; and (3) integrated, 3D-printed wells that enable a defined sample fractionation (chip-to-world interface). In proof of concept experiments both a mixture of fluorescence dyes and a mixture of amino acids were successfully separated in our 3D-printed μFFE device.
Collapse
Affiliation(s)
- John-Alexander Preuss
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, Hannover, 30167, Germany
| | - Gia Nam Nguyen
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, Hannover, 30167, Germany
| | - Virginia Berk
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, Hannover, 30167, Germany
| | - Janina Bahnemann
- Institute of Technical Chemistry, Leibniz University Hannover, Callinstraße 5, Hannover, 30167, Germany
| |
Collapse
|
6
|
Wu XQ, Liu Y, Feng PQ, Wei XH, Yang GM, Qiu XH, Ma JG. Design of a Zn-MOF biosensor via a ligand “lock” for the recognition and distinction of S-containing amino acids. Chem Commun (Camb) 2019; 55:4059-4062. [DOI: 10.1039/c9cc01701a] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
A new method of introducing a ‘lock’ ligand into the frame of MOFs is described to achieve the first example of a MOF-based biosensor for the recognition and distinction of S-containing amino acids.
Collapse
Affiliation(s)
- Xiao-Qin Wu
- Scientific Instrument Center
- Shanxi University
- Taiyuan
- China
- Department of Chemistry and Key Laboratory of Advanced Energy Materials Chemistry (MOE)
| | - Yan Liu
- Department of Chemistry and Key Laboratory of Advanced Energy Materials Chemistry (MOE)
- College of Chemistry
- Nankai University
- Tianjin 300071
- China
| | - Pei-Qi Feng
- Scientific Instrument Center
- Shanxi University
- Taiyuan
- China
| | - Xue-Hong Wei
- Scientific Instrument Center
- Shanxi University
- Taiyuan
- China
| | - Guang-Ming Yang
- Department of Chemistry and Key Laboratory of Advanced Energy Materials Chemistry (MOE)
- College of Chemistry
- Nankai University
- Tianjin 300071
- China
| | - Xiao-Hang Qiu
- Department of Chemistry and Key Laboratory of Advanced Energy Materials Chemistry (MOE)
- College of Chemistry
- Nankai University
- Tianjin 300071
- China
| | - Jian-Gong Ma
- Department of Chemistry and Key Laboratory of Advanced Energy Materials Chemistry (MOE)
- College of Chemistry
- Nankai University
- Tianjin 300071
- China
| |
Collapse
|
7
|
Kochmann S, Krylov SN. Quantitative Characterization of Molecular-Stream Separation. Anal Chem 2018; 90:9504-9509. [DOI: 10.1021/acs.analchem.8b02186] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Sven Kochmann
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| | - Sergey N. Krylov
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada
| |
Collapse
|
8
|
Continuous purification of reaction products by micro free-flow electrophoresis enabled by large area deep-UV fluorescence imaging. Anal Bioanal Chem 2017; 410:853-862. [DOI: 10.1007/s00216-017-0697-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Revised: 09/18/2017] [Accepted: 10/06/2017] [Indexed: 10/18/2022]
|
9
|
Nagl S. Micro free-flow isoelectric focusing with integrated optical pH sensors. Eng Life Sci 2017; 18:114-123. [PMID: 32624893 DOI: 10.1002/elsc.201700035] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Revised: 02/07/2017] [Accepted: 07/13/2017] [Indexed: 01/12/2023] Open
Abstract
Recently, a new observation method for monitoring of pH gradients in microfluidic free-flow electrophoresis has emerged. It is based on the use of chip-integrated fluorescent or luminescent micro sensor layers. These are able to monitor pH gradients in miniaturized separations in real time and spatially resolved; this is particularly useful in isoelectric focusing. Here these multifunctional microdevices that feature continuous separation, monitoring, and in some instances other functionalities, are reviewed. The employed microfabrication procedures to produce these devices are discussed and the different pH sensor matrices that were integrated and their applications in the separation of different types of biomolecules. The procedures for obtaining spatially resolved information about the separated molecules and the pH at the same time and different detection modalities to achieve this such as deep UV fluorescence as well as time-resolved referenced pH sensing and the integration of a precolumn labeling step into these platforms are also highlighted.
Collapse
Affiliation(s)
- Stefan Nagl
- Department of Chemistry The Hong Kong University of Science and Technology Kowloon Hong Kong SAR P. R. China
| |
Collapse
|
10
|
Kochmann S, Krylov SN. Image processing and analysis system for development and use of free flow electrophoresis chips. LAB ON A CHIP 2017; 17:256-266. [PMID: 27957577 DOI: 10.1039/c6lc01381c] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We present an image processing and analysis system to facilitate detailed performance analysis of free flow electrophoresis (FFE) chips. It consists of a cost-effective self-built imaging setup and a comprehensive customizable software suite. Both components were designed modularly to be accessible, adaptable, versatile, and automatable. The system provides tools for i) automated identification of chip features (e.g. separation zone and flow markers), ii) extraction and analysis of stream trajectories, and iii) evaluation of flow profiles and separation quality (e.g. determination of resolution). Equipped with these tools, the presented image processing and analysis system will enable faster development of FFE chips and applications. It will also serve as a robust detector for fluorescence-based analytical applications of FFE.
Collapse
Affiliation(s)
- Sven Kochmann
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada.
| | - Sergey N Krylov
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University, Toronto, Ontario M3J 1P3, Canada.
| |
Collapse
|
11
|
Kochmann S, Agostino FJ, LeBlanc JCY, Krylov SN. Hyphenation of Production-Scale Free-Flow Electrophoresis to Electrospray Ionization Mass Spectrometry Using a Highly Conductive Background Electrolyte. Anal Chem 2016; 88:8415-20. [PMID: 27462727 DOI: 10.1021/acs.analchem.6b02235] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In this technical note, we demonstrate the hyphenation of production-scale free-flow electrophoresis (FFE) and sheathless electrospray ionization mass spectrometry (ESI-MS). In contrast to previous hyphenation approaches, we used a highly conductive background electrolyte (BGE) required for production-scale FFE. We found that this kind of BGE as well as a production-scale setup leads to significant electric interference between FFE and MS. This interference prevents steady-state FFE operation. We examine this interference in detail and discuss possible solutions to this issue. We demonstrate that the straightforward grounding of the transfer line removes the influence of ESI-MS on FFE, but creates a current leak from the ESI interface, which adversely affects the ESI spray. Furthermore, we show that only the electrical disconnection of the ESI probe from the FFE-MS transfer line suppresses this undesirable current. In order to facilitate the electrical disconnection we used a low conductivity, silica-based ESI probe with withdrawn inner capillary. This approach allowed the interference-free hyphenation of production-scale FFE (using a highly conductive BGE) with ESI-MS.
Collapse
Affiliation(s)
- Sven Kochmann
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University , Toronto, Ontario M3J 1P3, Canada
| | - Fletcher J Agostino
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University , Toronto, Ontario M3J 1P3, Canada
| | | | - Sergey N Krylov
- Department of Chemistry and Centre for Research on Biomolecular Interactions, York University , Toronto, Ontario M3J 1P3, Canada
| |
Collapse
|
12
|
Dietze C, Schulze S, Ohla S, Gilmore K, Seeberger PH, Belder D. Integrated on-chip mass spectrometry reaction monitoring in microfluidic devices containing porous polymer monolithic columns. Analyst 2016; 141:5412-6. [PMID: 27373801 DOI: 10.1039/c6an01467d] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Chip-based microfluidics enable the seamless integration of different functions into single devices. Here, we present microfluidic chips containing porous polymer monolithic columns as a means to facilitate chemical transformations as well as both downstream chromatographic separation and mass spectrometric analysis. Rapid liquid phase lithography prototyping creates the multifunctional device economically.
Collapse
Affiliation(s)
- C Dietze
- Institut für Analytische Chemie, Universität Leipzig, Linnéstr. 3, D-04103 Leipzig, Germany.
| | | | | | | | | | | |
Collapse
|
13
|
Herzog C, Poehler E, Peretzki AJ, Borisov SM, Aigner D, Mayr T, Nagl S. Continuous on-chip fluorescence labelling, free-flow isoelectric focusing and marker-free isoelectric point determination of proteins and peptides. LAB ON A CHIP 2016; 16:1565-1572. [PMID: 27064144 DOI: 10.1039/c6lc00055j] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present a microfluidic platform that contains a micro flow reactor for on-chip biomolecule labelling that is directly followed by a separation bed for continuous free-flow electrophoresis and has an integrated hydrogel-based near-infrared fluorescent pH sensor layer. Using this assembly, labelling of protein and peptide mixtures, their separation via free-flow isoelectric focusing and the determination of the isoelectric point (pI) of the separated products via the integrated sensor layer could be carried out within typically around 5 minutes. Spatially-resolved immobilization of fluidic and sensing structures was carried out via multistep photolithography. The assembly was characterized and optimized with respect to their fluidic and pH sensing properties and applied in the IEF of model proteins, peptides and a tryptic digest from physalaemine. We have therefore realized continuous sample preparation and preparative separation, analyte detection, process observation and analyte assignment capability based on pI on a single platform the size of a microscope slide.
Collapse
Affiliation(s)
- Christin Herzog
- Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103 Leipzig, Germany.
| | - Elisabeth Poehler
- Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103 Leipzig, Germany.
| | - Andrea J Peretzki
- Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103 Leipzig, Germany.
| | - Sergey M Borisov
- Institut für Analytische Chemie und Lebensmittelchemie, Technische Universität Graz, Stremayrgasse 9/III, 8010 Graz, Austria
| | - Daniel Aigner
- Institut für Analytische Chemie und Lebensmittelchemie, Technische Universität Graz, Stremayrgasse 9/III, 8010 Graz, Austria
| | - Torsten Mayr
- Institut für Analytische Chemie und Lebensmittelchemie, Technische Universität Graz, Stremayrgasse 9/III, 8010 Graz, Austria
| | - Stefan Nagl
- Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103 Leipzig, Germany.
| |
Collapse
|
14
|
Kašička V. Recent developments in capillary and microchip electroseparations of peptides (2013-middle 2015). Electrophoresis 2015; 37:162-88. [DOI: 10.1002/elps.201500329] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2015] [Revised: 08/25/2015] [Accepted: 08/25/2015] [Indexed: 12/16/2022]
Affiliation(s)
- Václav Kašička
- Institute of Organic Chemistry and Biochemistry, v.v.i; The Czech Academy of Sciences; Prague Czech Republic
| |
Collapse
|
15
|
Agostino FJ, Krylov SN. Advances in steady-state continuous-flow purification by small-scale free-flow electrophoresis. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.03.023] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
16
|
Dietze C, Scholl T, Ohla S, Appun J, Schneider C, Belder D. Rapid prototyping of microfluidic chips for dead-volume-free MS coupling. Anal Bioanal Chem 2015; 407:8735-43. [DOI: 10.1007/s00216-015-9027-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2015] [Revised: 08/20/2015] [Accepted: 09/03/2015] [Indexed: 11/30/2022]
|
17
|
Stockinger S, Troendlin J, Rominger F, Trapp O. On-Column Reaction Set-Up for High-Throughput Screenings and Mechanistic Investigations. Adv Synth Catal 2015. [DOI: 10.1002/adsc.201500311] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
18
|
Glasnov T. Highlights from the Flow Chemistry Literature 2013 (Part 4). J Flow Chem 2015. [DOI: 10.1556/jfc-d-14-00002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
19
|
Benz C, Boomhoff M, Appun J, Schneider C, Belder D. Chip-Based Free-Flow Electrophoresis with Integrated Nanospray Mass-Spectrometry. Angew Chem Int Ed Engl 2015; 54:2766-70. [DOI: 10.1002/anie.201409663] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Revised: 11/12/2014] [Indexed: 11/07/2022]
|
20
|
Benz C, Boomhoff M, Appun J, Schneider C, Belder D. Chip-basierte Freiflusselektrophorese mit integrierter Nanospray-Massenspektrometrie-Kopplung. Angew Chem Int Ed Engl 2015. [DOI: 10.1002/ange.201409663] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
21
|
Ley SV, Fitzpatrick DE, Ingham RJ, Myers RM. Organic synthesis: march of the machines. Angew Chem Int Ed Engl 2015; 54:3449-64. [PMID: 25586940 DOI: 10.1002/anie.201410744] [Citation(s) in RCA: 309] [Impact Index Per Article: 30.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2014] [Indexed: 12/12/2022]
Abstract
Organic synthesis is changing; in a world where budgets are constrained and the environmental impacts of practice are scrutinized, it is increasingly recognized that the efficient use of human resource is just as important as material use. New technologies and machines have found use as methods for transforming the way we work, addressing these issues encountered in research laboratories by enabling chemists to adopt a more holistic systems approach in their work. Modern developments in this area promote a multi-disciplinary approach and work is more efficient as a result. This Review focuses on the concepts, procedures and methods that have far-reaching implications in the chemistry world. Technologies have been grouped as topics of opportunity and their recent applications in innovative research laboratories are described.
Collapse
Affiliation(s)
- Steven V Ley
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW (UK).
| | | | | | | |
Collapse
|
22
|
Ley SV, Fitzpatrick DE, Ingham RJ, Myers RM. Organische Synthese: Vormarsch der Maschinen. Angew Chem Int Ed Engl 2015. [DOI: 10.1002/ange.201410744] [Citation(s) in RCA: 76] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
23
|
Meier TA, Beulig RJ, Klinge E, Fuss M, Ohla S, Belder D. On-chip monitoring of chemical syntheses in microdroplets via surface-enhanced Raman spectroscopy. Chem Commun (Camb) 2015; 51:8588-91. [DOI: 10.1039/c4cc09595b] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
An approach for inline monitoring of organic syntheses in a microfluidic droplet chip via surface-enhanced Raman spectroscopy is presented. In a proof of concept it was successfully applied to follow thiazole syntheses in real-time.
Collapse
Affiliation(s)
- T.-A. Meier
- Institut für Analytische Chemie
- Universität Leipzig
- D-04103 Leipzig
- Germany
| | - R. J. Beulig
- Institut für Analytische Chemie
- Universität Leipzig
- D-04103 Leipzig
- Germany
| | - E. Klinge
- Institut für Analytische Chemie
- Universität Leipzig
- D-04103 Leipzig
- Germany
| | - M. Fuss
- Institut für Analytische Chemie
- Universität Leipzig
- D-04103 Leipzig
- Germany
| | - S. Ohla
- Institut für Analytische Chemie
- Universität Leipzig
- D-04103 Leipzig
- Germany
| | - D. Belder
- Institut für Analytische Chemie
- Universität Leipzig
- D-04103 Leipzig
- Germany
| |
Collapse
|
24
|
Present state of microchip electrophoresis: state of the art and routine applications. J Chromatogr A 2014; 1382:66-85. [PMID: 25529267 DOI: 10.1016/j.chroma.2014.11.034] [Citation(s) in RCA: 130] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 11/07/2014] [Accepted: 11/12/2014] [Indexed: 12/20/2022]
Abstract
Microchip electrophoresis (MCE) was one of the earliest applications of the micro-total analysis system (μ-TAS) concept, whose aim is to reduce analysis time and reagent and sample consumption while increasing throughput and portability by miniaturizing analytical laboratory procedures onto a microfluidic chip. More than two decades on, electrophoresis remains the most common separation technique used in microfluidic applications. MCE-based instruments have had some commercial success and have found application in many disciplines. This review will consider the present state of MCE including recent advances in technology and both novel and routine applications in the laboratory. We will also attempt to assess the impact of MCE in the scientific community and its prospects for the future.
Collapse
|
25
|
|
26
|
Herzog C, Beckert E, Nagl S. Rapid Isoelectric Point Determination in a Miniaturized Preparative Separation Using Jet-Dispensed Optical pH Sensors and Micro Free-Flow Electrophoresis. Anal Chem 2014; 86:9533-9. [DOI: 10.1021/ac501783r] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Christin Herzog
- Institut
für Analytische Chemie, Universität Leipzig, Linnéstrasse
3, 04103 Leipzig, Germany
| | - Erik Beckert
- Fraunhofer-Institut für Angewandte Optik und Feinmechanik (IOF), Albert-Einstein-Strasse 7, 07745 Jena, Germany
| | - Stefan Nagl
- Institut
für Analytische Chemie, Universität Leipzig, Linnéstrasse
3, 04103 Leipzig, Germany
| |
Collapse
|
27
|
Thürmann S, Belder D. Phase-optimized chip-based liquid chromatography. Anal Bioanal Chem 2014; 406:6599-606. [DOI: 10.1007/s00216-014-8087-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Revised: 07/25/2014] [Accepted: 07/30/2014] [Indexed: 11/30/2022]
|
28
|
Hackl C, Beyreiss R, Geissler D, Jezierski S, Belder D. Rapid prototyping of electrochromatography chips for improved two-photon excited fluorescence detection. Anal Chem 2014; 86:3773-9. [PMID: 24666258 DOI: 10.1021/ac500793e] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In the present study, we introduce two-photon excitation at 532 nm for label-free fluorescence detection in chip electrochromatography. Two-photon excitation at 532 nm offers a promising alternative to one-photon excitation at 266 nm, as it enables the use of economic chip materials instead of fused silica. In order to demonstrate these benefits, one-photon and two-photon induced fluorescence detection are compared in different chip layouts and materials with respect to the achievable sensitivity in the detection of polycyclic aromatic hydrocarbons (PAHs). Customized chromatography chips with cover or bottom slides of different material and thickness are produced by means of a rapid prototyping method based on liquid-phase lithography. The design of thin bottom chips (180 μm) enables the use of high-performance immersion objectives with low working distances, which allows one to exploit the full potential of two-photon excitation for a sensitive detection. The developed method is applied for label-free analysis of PAHs separated on a polymer monolith inside polymer glass sandwich chips made from fused silica or soda-lime glass. The obtained limits of detection range from 40 nM to 1.95 μM, with similar sensitivities in fused silica thin bottom chips for one-photon and two-photon excitation. In deep-UV non- or less-transparent devices two-photon excitation is mandatory for label-free detection of aromatics with high sensitivity.
Collapse
Affiliation(s)
- Claudia Hackl
- Institut für Analytische Chemie, Universität Leipzig , Linnéstraße 3, 04103 Leipzig, Germany
| | | | | | | | | |
Collapse
|