1
|
García-Azuma R, Werner K, Revilla-Monsalve C, Trinidad O, Altamirano-Bustamante NF, Altamirano-Bustamante MM. Unveiling the state of the art: a systematic review and meta-analysis of paper-based microfluidic devices. Front Bioeng Biotechnol 2024; 12:1421831. [PMID: 39234268 PMCID: PMC11372461 DOI: 10.3389/fbioe.2024.1421831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 07/29/2024] [Indexed: 09/06/2024] Open
Abstract
Introduction This systematic review and meta-analysis present a comprehensive evaluation of paper-based microfluidic devices, focusing on their applications in immunoassays. These devices are emerging as innovative solutions to democratize access to diagnostic technologies, especially in resource-limited settings. Our review consolidates findings from diverse studies to outline advancements in paper-based microfluidic technology, including design intricacies and operational efficacy. Key advantages such as low cost, portability, and ease of use are highlighted. Materials and Methods The review categorizes literature based on the design and operational nuances of these diagnostic tools, exploring various methodologies, fabrication techniques, detection methods, and applications, particularly in protein science. The meta-analysis extends to the diverse applications of these technologies, providing a framework for classifying and stratifying their uses in diagnostics. Results and discussion Notable findings include a critical analysis of performance metrics, such as sensitivity and specificity. The review addresses challenges, including the need for further validation and optimization for broader clinical applications. A critical discussion on the validation processes, including cross-validation and rigorous control testing, is provided to ensure the robustness of microfluidic devices. This study offers novel insights into the computational strategies underpinning these technologies and serves as a comprehensive roadmap for future research, potentially broadening the impact across the protein science universe.
Collapse
Affiliation(s)
- Rodrigo García-Azuma
- Unidad de Investigación en Enfermedades Metabólicas, Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Ciudad de México, Mexico
| | - Karen Werner
- Unidad de Investigación en Enfermedades Metabólicas, Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Ciudad de México, Mexico
| | - Cristina Revilla-Monsalve
- Unidad de Investigación en Enfermedades Metabólicas, Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Ciudad de México, Mexico
| | - Oscar Trinidad
- Unidad de Investigación en Enfermedades Metabólicas, Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Ciudad de México, Mexico
| | | | - Myriam M Altamirano-Bustamante
- Unidad de Investigación en Enfermedades Metabólicas, Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Ciudad de México, Mexico
| |
Collapse
|
2
|
Gradisteanu Pircalabioru G, Raileanu M, Dionisie MV, Lixandru-Petre IO, Iliescu C. Fast detection of bacterial gut pathogens on miniaturized devices: an overview. Expert Rev Mol Diagn 2024; 24:201-218. [PMID: 38347807 DOI: 10.1080/14737159.2024.2316756] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 02/06/2024] [Indexed: 03/23/2024]
Abstract
INTRODUCTION Gut microbes pose challenges like colon inflammation, deadly diarrhea, antimicrobial resistance dissemination, and chronic disease onset. Development of early, rapid and specific diagnosis tools is essential for improving infection control. Point-of-care testing (POCT) systems offer rapid, sensitive, low-cost and sample-to-answer methods for microbe detection from various clinical and environmental samples, bringing the advantages of portability, automation, and simple operation. AREAS COVERED Rapid detection of gut microbes can be done using a wide array of techniques including biosensors, immunological assays, electrochemical impedance spectroscopy, mass spectrometry and molecular biology. Inclusion of Internet of Things, machine learning, and smartphone-based point-of-care applications is an important aspect of POCT. In this review, the authors discuss various fast diagnostic platforms for gut pathogens and their main challenges. EXPERT OPINION Developing effective assays for microbe detection can be complex. Assay design must consider factors like target selection, real-time and multiplex detection, sample type, reagent stability and storage, primer/probe design, and optimizing reaction conditions for accuracy and sensitivity. Mitigating these challenges requires interdisciplinary collaboration among scientists, clinicians, engineers, and industry partners. Future efforts are essential to enhance sensitivity, specificity, and versatility of POCT systems for gut microbe detection and quantification, advancing infectious disease diagnostics and management.
Collapse
Affiliation(s)
- Gratiela Gradisteanu Pircalabioru
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
- Division of Earth, Environmental and Life Sciences, The Research Institute of University of Bucharest (ICUB), Bucharest, Romania
- Academy of Romanian Scientists, Bucharest, Romania
| | - Mina Raileanu
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
- Department of Life and Environmental Physics, Horia Hulubei National Institute of Physics and Nuclear Engineering, Magurele, Romania
| | - Mihai Viorel Dionisie
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
| | - Irina-Oana Lixandru-Petre
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
| | - Ciprian Iliescu
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
- Academy of Romanian Scientists, Bucharest, Romania
- Microsystems in Biomedical and Environmental Applications, National Research and Development Institute for Microtechnology, Bucharest, Romania
| |
Collapse
|
3
|
Santhosh M, Park T. Smartphone-integrated paper-based biosensor for sensitive fluorometric ethanol quantification. Mikrochim Acta 2023; 190:477. [PMID: 37993705 DOI: 10.1007/s00604-023-06063-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 10/21/2023] [Indexed: 11/24/2023]
Abstract
The development of fluorometric paper-based analytical devices (fPADs) integrated with smartphone for fluorometric quantification of ethanol in an instrument-free and portable setup is described. The NAD+-dependent alcohol dehydrogenase immobilized within chitosan modified paper substate was utilized as a bio-recognition element and enzymatically generated NADH was used as a fluorescent probe. 3D-printed imaging setup which houses a paper chip holder and UV-light emitting device (LED) was developed for rapid, accurate capture of the fluorescent images. The biocompatible chitosan layer covering the paper provides a feasible environment for enzyme immobilization and enhances the fluorescence signal. The developed fPADs exhibited high sensitivity for ethanol detection and has a linear range for ethanol detection from 17 µM to 8.75 mM (R2 =0.99). Additionally, the fPADs were applied to quantify ethanol in four different wine samples including red, white, rose, and sparkling wines successfully. Moreover, the fPADs produce reproducible signals without loss of enzyme activity for at least 14 days and ~80% activity remained till 28 days. Thus, the proposed approach can provide a facile, affordable, portable, and instrument-free tool for the onsite quantification of ethanol in real samples and is applicable for food quality controls.
Collapse
Affiliation(s)
- Mallesh Santhosh
- Smart Agriculture Innovation Center, Kyungpook National University, Daegu, Republic of Korea
| | - Tusan Park
- Smart Agriculture Innovation Center, Kyungpook National University, Daegu, Republic of Korea.
- Major in Bio-industrial Machinery Engineering, Kyungpook National University, Daegu, Republic of Korea.
| |
Collapse
|
4
|
Ebrahimi G, Pakchin PS, Mota A, Omidian H, Omidi Y. Electrochemical microfluidic paper-based analytical devices for cancer biomarker detection: From 2D to 3D sensing systems. Talanta 2023; 257:124370. [PMID: 36858013 DOI: 10.1016/j.talanta.2023.124370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 02/06/2023] [Accepted: 02/13/2023] [Indexed: 02/18/2023]
Abstract
Microfluidic paper-based analytical devices (μPADs) offer a unique possibility for a cost-effective portable and rapid detection of a wide range of small molecules and macromolecules and even microorganisms. In this line, electrochemical detection methods are key techniques for the qualitative analysis of different types of ligands. The electrochemical sensing μPADs have been devised for the rapid, accurate, and quantitative detection of oncomarkers through two-/three-dimensional (2D/3D) approaches. The 2D μPADs were first developed and then transformed into 3D systems via folding and/or twisting of paper. The microfluidic channels and connections were created within the layers of paper. Based on the fabrication methods, 3D μPADs can be classified into origami and stacking devices. Various fabrication methods and materials have been used to create hydrophilic channels in μPADs, among which the wax printing technique is the most common method in fabricating μPADs. In this review, we discuss the fabrication and design strategies of μPADs, elaborate on their detection modes, and highlight their applications in affinity-based electrochemical μPADs methods for the detection of oncomarkers.
Collapse
Affiliation(s)
- Ghasem Ebrahimi
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran; Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Parvin Samadi Pakchin
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ali Mota
- Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hossein Omidian
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA
| | - Yadollah Omidi
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA.
| |
Collapse
|
5
|
Mitrogiannopoulou AM, Tselepi V, Ellinas K. Polymeric and Paper-Based Lab-on-a-Chip Devices in Food Safety: A Review. MICROMACHINES 2023; 14:986. [PMID: 37241610 PMCID: PMC10223399 DOI: 10.3390/mi14050986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 04/27/2023] [Accepted: 04/28/2023] [Indexed: 05/28/2023]
Abstract
Food quality and safety are important to protect consumers from foodborne illnesses. Currently, laboratory scale analysis, which takes several days to complete, is the main way to ensure the absence of pathogenic microorganisms in a wide range of food products. However, new methods such as PCR, ELISA, or even accelerated plate culture tests have been proposed for the rapid detection of pathogens. Lab-on-chip (LOC) devices and microfluidics are miniaturized devices that can enable faster, easier, and at the point of interest analysis. Nowadays, methods such as PCR are often coupled with microfluidics, providing new LOC devices that can replace or complement the standard methods by offering highly sensitive, fast, and on-site analysis. This review's objective is to present an overview of recent advances in LOCs used for the identification of the most prevalent foodborne and waterborne pathogens that put consumer health at risk. In particular, the paper is organized as follows: first, we discuss the main fabrication methods of microfluidics as well as the most popular materials used, and then we present recent literature examples for LOCs used for the detection of pathogenic bacteria found in water and other food samples. In the final section, we summarize our findings and also provide our point of view on the challenges and opportunities in the field.
Collapse
Affiliation(s)
| | | | - Kosmas Ellinas
- Department of Food Science and Nutrition, School of the Environment, University of the Aegean, Ierou Lochou & Makrygianni St, GR 81400 Myrina, Greece
| |
Collapse
|
6
|
Nodi SS, Paul M, Robinson N, Wang L, Rehman SU. Determination of Munsell Soil Colour Using Smartphones. SENSORS (BASEL, SWITZERLAND) 2023; 23:3181. [PMID: 36991891 PMCID: PMC10058488 DOI: 10.3390/s23063181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/11/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
Soil colour is one of the most important factors in agriculture for monitoring soil health and determining its properties. For this purpose, Munsell soil colour charts are widely used by archaeologists, scientists, and farmers. The process of determining soil colour from the chart is subjective and error-prone. In this study, we used popular smartphones to capture soil colours from images in the Munsell Soil Colour Book (MSCB) to determine the colour digitally. These captured soil colours are then compared with the true colour determined using a commonly used sensor (Nix Pro-2). We have observed that there are colour reading discrepancies between smartphone and Nix Pro-provided readings. To address this issue, we investigated different colour models and finally introduced a colour-intensity relationship between the images captured by Nix Pro and smartphones by exploring different distance functions. Thus, the aim of this study is to determine the Munsell soil colour accurately from the MSCB by adjusting the pixel intensity of the smartphone-captured images. Without any adjustment when the accuracy of individual Munsell soil colour determination is only 9% for the top 5 predictions, the accuracy of the proposed method is 74%, which is significant.
Collapse
Affiliation(s)
- Sadia Sabrin Nodi
- School of Computing, Mathematics and Engineering, Charles Sturt University, Bathurst, NSW 2795, Australia
| | - Manoranjan Paul
- School of Computing, Mathematics and Engineering, Charles Sturt University, Bathurst, NSW 2795, Australia
| | - Nathan Robinson
- Centre for eResearch and Digital Innovation, Federation University, Mount Helen, VIC 3350, Australia
| | - Liang Wang
- Global Centre for Environmental Remediation, The University of Newcastle, Callaghan, NSW 2308, Australia
| | - Sabih ur Rehman
- School of Computing, Mathematics and Engineering, Charles Sturt University, Port Macquarie, NSW 2444, Australia
| |
Collapse
|
7
|
Yu Q, Chen X, Qi L, Yang H, Wang Y, Zhang M, Huang K, Yuan X. Smartphone readable colorimetry and ICP-MS dual-mode sensing platform for ultrasensitive and label-free detection of Escherichia coli based on filter-assisted separation. Talanta 2022; 251:123760. [DOI: 10.1016/j.talanta.2022.123760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 10/16/2022]
|
8
|
Rodoplu D, Chang C, Kao C, Hsu C. A micro-pupil device for point-of-care testing of viable Escherichia coli in tap water. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
9
|
Schaumburg F, Vidocevich JP, Gerlero GS, Pujato N, Macagno J, Kler PA, Berli CLA. A free customizable tool for easy integration of microfluidics and smartphones. Sci Rep 2022; 12:8969. [PMID: 35624294 PMCID: PMC9142529 DOI: 10.1038/s41598-022-13099-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 03/30/2022] [Indexed: 12/04/2022] Open
Abstract
The integration of smartphones and microfluidics is nowadays the best possible route to achieve effective point-of-need testing (PONT), a concept increasingly demanded in the fields of human health, agriculture, food safety, and environmental monitoring. Nevertheless, efforts are still required to integrally seize all the advantages of smartphones, as well as to share the developments in easily adoptable formats. For this purpose, here we present the free platform appuente that was designed for the easy integration of microfluidic chips, smartphones, and the cloud. It includes a mobile app for end users, which provides chip identification and tracking, guidance and control, processing, smart-imaging, result reporting and cloud and Internet of Things (IoT) integration. The platform also includes a web app for PONT developers, to easily customize their mobile apps and manage the data of administered tests. Three application examples were used to validate appuente: a dummy grayscale detector that mimics quantitative colorimetric tests, a root elongation assay for pesticide toxicity assessment, and a lateral flow immunoassay for leptospirosis detection. The platform openly offers fast prototyping of smartphone apps to the wide community of lab-on-a-chip developers, and also serves as a friendly framework for new techniques, IoT integration and further capabilities. Exploiting these advantages will certainly help to enlarge the use of PONT with real-time connectivity in the near future.
Collapse
Affiliation(s)
- Federico Schaumburg
- Instituto de Desarrollo Tecnológico para la Industria Química (INTEC, UNL-CONICET), Colectora RN 168, S3000GLN, Santa Fe, Argentina.
| | - Juan P Vidocevich
- Instituto de Desarrollo Tecnológico para la Industria Química (INTEC, UNL-CONICET), Colectora RN 168, S3000GLN, Santa Fe, Argentina
| | - Gabriel S Gerlero
- Centro de Investigación de Métodos Computacionales (CIMEC, UNL-CONICET), Colectora RN 168, S3000GLN, Santa Fe, Argentina
| | - Nazarena Pujato
- Laboratorio de Tecnología Inmunológica (FBCB, UNL), Colectora RN 168, S3000GLN, Santa Fe, Argentina
| | - Joana Macagno
- Instituto de Desarrollo Tecnológico para la Industria Química (INTEC, UNL-CONICET), Colectora RN 168, S3000GLN, Santa Fe, Argentina
| | - Pablo A Kler
- Centro de Investigación de Métodos Computacionales (CIMEC, UNL-CONICET), Colectora RN 168, S3000GLN, Santa Fe, Argentina
| | - Claudio L A Berli
- Instituto de Desarrollo Tecnológico para la Industria Química (INTEC, UNL-CONICET), Colectora RN 168, S3000GLN, Santa Fe, Argentina.
| |
Collapse
|
10
|
Tan W, Zhang L, Jarujamrus P, C G Doery J, Shen W. Improvement Strategies on Colorimetric Performance and Practical Applications of Paper-based Analytical Devices. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107562] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
11
|
Kim S, Day AS, Yoon JY. Machine learning classification of bacterial species using mix-and-match reagents on paper microfluidic chips and smartphone-based capillary flow analysis. Anal Bioanal Chem 2022; 414:3895-3904. [DOI: 10.1007/s00216-022-04031-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 03/15/2022] [Accepted: 03/18/2022] [Indexed: 11/01/2022]
|
12
|
Resmi PE, Suneesh PV, Ramachandran T, Babu TGS. Paper based micro/nanofluidics devices for biomedical applications. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:159-190. [PMID: 35033283 DOI: 10.1016/bs.pmbts.2021.07.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
This chapter details the significance, fabrication and biomedical applications of paper-based microfluidic devices. The first part of the chapter describes the importance of paper diagnostic devices, highlighting pretreatment, dipsticks, lateral flow assays, and microPADs. Various methods followed for the fabrication of the paper analytical devices are discussed in the second part. The last part is about some of the important biomedical applications of paper analytical devices. Finally, the challenges and research gaps in the paper microfluidics for biomedical applications are presented.
Collapse
Affiliation(s)
- P E Resmi
- Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India
| | - P V Suneesh
- Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India; Department of Sciences, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India
| | - T Ramachandran
- Department of Sciences, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India
| | - T G Satheesh Babu
- Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India; Department of Sciences, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India.
| |
Collapse
|
13
|
Kholafazad-Kordasht H, Hasanzadeh M, Seidi F. Smartphone based immunosensors as next generation of healthcare tools: Technical and analytical overview towards improvement of personalized medicine. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116455] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
14
|
Walia S, Bhatnagar I, Liu J, Mitra SK, Asthana A. A novel method for fabrication of paper-based microfluidic devices using BSA-ink. Int J Biol Macromol 2021; 193:1617-1622. [PMID: 34774599 DOI: 10.1016/j.ijbiomac.2021.10.224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 09/28/2021] [Accepted: 10/30/2021] [Indexed: 10/19/2022]
Abstract
This paper describes the fabrication of paper-based microfluidic devices using a novel, inexpensive ink composed of bovine serum albumin (BSA), utilizing BSA's thermal denaturation and aggregation to create a hydrophobic barrier on Whatman® Grade 4 filter paper. A 20% aqueous solution of BSA was inked onto the paper using a pen plotter at moderate speed (5 cm/s) with desired shape and size followed by heating at 80 °C to denature the BSA leading to hydrophobic barriers formation, whereas below 80 °C the barrier layer is prone to collapse. The minimum line gap and line width of ~1 mm and ~1.3 mm were achieved. Finally, a proof-of-concept glucose sensing was shown while addressing the issue of the coffee ring effect using the biopolymer NanoCheck-ATH® from ChitoLytic Inc. The glucose concentration limit of detection (LOD) as low as 0.2 mg/mL was estimated. The developed technique offers ease of fabrication, high reproducibility, cost-effectiveness, and is environmentally friendly.
Collapse
Affiliation(s)
- Sunil Walia
- Micro & Nano-scale Transport Laboratory, Waterloo Institute for Nanotechnology, Department of Mechanical & Mechatronics Engineering, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Ira Bhatnagar
- CSIR-Centre for Cellular & Molecular Biology, Habsiguda, Uppal Road, Hyderabad 500 007, Telangana, India
| | - Juewen Liu
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Sushanta K Mitra
- Micro & Nano-scale Transport Laboratory, Waterloo Institute for Nanotechnology, Department of Mechanical & Mechatronics Engineering, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
| | - Amit Asthana
- Department of Medical Devices, National Institute of Pharmaceutical Education and Research (NIPER), Hyderabad 500039, India; CSIR-Centre for Cellular & Molecular Biology, Habsiguda, Uppal Road, Hyderabad 500 007, Telangana, India.
| |
Collapse
|
15
|
Fu X, Sun J, Liang R, Guo H, Wang L, Sun X. Application progress of microfluidics-integrated biosensing platforms in the detection of foodborne pathogens. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.07.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
16
|
Schackart KE, Yoon JY. Machine Learning Enhances the Performance of Bioreceptor-Free Biosensors. SENSORS (BASEL, SWITZERLAND) 2021; 21:5519. [PMID: 34450960 PMCID: PMC8401027 DOI: 10.3390/s21165519] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 08/09/2021] [Accepted: 08/13/2021] [Indexed: 01/06/2023]
Abstract
Since their inception, biosensors have frequently employed simple regression models to calculate analyte composition based on the biosensor's signal magnitude. Traditionally, bioreceptors provide excellent sensitivity and specificity to the biosensor. Increasingly, however, bioreceptor-free biosensors have been developed for a wide range of applications. Without a bioreceptor, maintaining strong specificity and a low limit of detection have become the major challenge. Machine learning (ML) has been introduced to improve the performance of these biosensors, effectively replacing the bioreceptor with modeling to gain specificity. Here, we present how ML has been used to enhance the performance of these bioreceptor-free biosensors. Particularly, we discuss how ML has been used for imaging, Enose and Etongue, and surface-enhanced Raman spectroscopy (SERS) biosensors. Notably, principal component analysis (PCA) combined with support vector machine (SVM) and various artificial neural network (ANN) algorithms have shown outstanding performance in a variety of tasks. We anticipate that ML will continue to improve the performance of bioreceptor-free biosensors, especially with the prospects of sharing trained models and cloud computing for mobile computation. To facilitate this, the biosensing community would benefit from increased contributions to open-access data repositories for biosensor data.
Collapse
Affiliation(s)
- Kenneth E. Schackart
- Department of Biosystems Engineering, The University of Arizona, Tucson, AZ 85721, USA;
| | - Jeong-Yeol Yoon
- Department of Biosystems Engineering, The University of Arizona, Tucson, AZ 85721, USA;
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| |
Collapse
|
17
|
[Applications of microfluidic paper-based chips in environmental analysis and detection]. Se Pu 2021; 39:802-815. [PMID: 34212581 PMCID: PMC9404056 DOI: 10.3724/sp.j.1123.2020.09004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
近年来,微流控纸芯片由于低成本、便携化、检测快等优点,在需要快速检测的环境分析领域中展现出了巨大的应用前景。该综述从微流控纸芯片在环境分析中的应用角度,总结归纳了微流控纸芯片在环境分析中的最新研究进展,并展望了其在未来的发展趋势与挑战。论文内容引用150余篇源于科学引文索引(SCI)与中文核心期刊中的相关论文。该综述包括微流控纸芯片在环境检测中的优势与制造方法介绍;电化学法、荧光法、比色法、表面增强拉曼法、集成传感法等基于纸芯片的先进分析方法介绍;根据环境分析目标物种类,如重金属离子、营养盐、农药、微生物、抗生素以及其他污染物等,对纸芯片的最新应用现状进行了举例评述;基于微流控纸芯片的环境分析研究的未来发展趋势和前景展望。通过综述近期相关研究,表明微流控纸芯片从提出至今虽然只有十几年的发展历程,但其在环境分析研究中的发展却十分迅速。微流控纸芯片可以根据不同的环境条件和检测要求灵活选择制作与分析方法,实现最佳的检测效果。但是微流控纸芯片也面临一些挑战,如纸张机械强度不足、流体控制程度不佳等问题。这些问题指出了微流控纸芯片在环境检测领域的发展趋势,相信随着不断深入的研究,纸芯片将会在未来的环境分析中发挥更大作用。
Collapse
|
18
|
Ruttanakorn K, Phadungcharoen N, Laiwattanapaisal W, Chinsriwongkul A, Rojanarata T. Smartphone-based technique for the determination of a titration equivalence point from an RGB linear-segment curve with an example application to miniaturized titration of sodium chloride injections. Talanta 2021; 233:122602. [PMID: 34215090 DOI: 10.1016/j.talanta.2021.122602] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 06/07/2021] [Accepted: 06/08/2021] [Indexed: 12/29/2022]
Abstract
A smartphone-based technique for determining the titration equivalence point from a linear-segment curve was developed for the first time. In this method, a titrant in an increasing microliter-volume was added to a set of sample aliquots containing an indicator covering both sides of the equivalence point. The solutions were subsequently photographed in one shot, in a dark box using a smartphone camera and an illuminating screen of a tablet or light emitting diode lamps arranged below a white acrylic sheet as a light source. After the colors of the solutions were delineated to Red, Green, and Blue (RGB) values, 1/log G was used to construct a plot in which the equivalence point was located at the intersection of the two lines in the region before and after the equivalence point. The technique was successfully applied to the miniaturized titration of sodium chloride injections, showing the good linear relationship of equivalence points to the sodium chloride concentration in the range of 0.4163-0.9675% w/v (R2 of 0.9998). The assay was accurate (% recovery of 98.92-100.52), precise (% relative standard deviation ≤ 1.20), and unaffected by the use of different types of microplates, smartphones, and RGB analysis tools. Additionally, it required no expensive nor complicated equipment and offered the possibility of performing analysis on a single smartphone device when it was used with a mobile application developed to aid data processing and immediate production of reports of analytical results.
Collapse
Affiliation(s)
- Kanong Ruttanakorn
- Pharmaceutical Development of Green Innovations Group (PDGIG) and Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Silpakorn University, Sanam Chandra Palace Campus, Nakhon Pathom, 73000, Thailand
| | - Noppharat Phadungcharoen
- Pharmaceutical Development of Green Innovations Group (PDGIG) and Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Silpakorn University, Sanam Chandra Palace Campus, Nakhon Pathom, 73000, Thailand
| | - Wanida Laiwattanapaisal
- Biosensors and Bioanalytical Technology for Cells and Innovative Testing Device Research Unit, Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| | | | - Theerasak Rojanarata
- Pharmaceutical Development of Green Innovations Group (PDGIG) and Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Silpakorn University, Sanam Chandra Palace Campus, Nakhon Pathom, 73000, Thailand.
| |
Collapse
|
19
|
Kim S, Lee MH, Wiwasuku T, Day AS, Youngme S, Hwang DS, Yoon JY. Human sensor-inspired supervised machine learning of smartphone-based paper microfluidic analysis for bacterial species classification. Biosens Bioelectron 2021; 188:113335. [PMID: 34030093 DOI: 10.1016/j.bios.2021.113335] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 05/06/2021] [Accepted: 05/10/2021] [Indexed: 12/27/2022]
Abstract
Bacteria identification has predominantly been conducted using specific bioreceptors such as antibodies or nucleic acid sequences. This approach may be inappropriate for environmental monitoring when the user does not know the target bacterial species and for screening complex water samples with many unknown bacterial species. In this work, we investigate the supervised machine learning of the bacteria-particle aggregation pattern induced by the peptide sets identified from the biofilm-bacteria interface. Each peptide is covalently conjugated to polystyrene particles and loaded together with bacterial suspensions onto paper microfluidic chips. Each peptide interacts with bacterial species to a different extent, leading to varying sizes of particle aggregation. This aggregation changes the surface tension and viscosity of the liquid flowing through the paper pores, altering the flow velocity at different extents. A smartphone camera captures this flow velocity without being affected by ambient and environmental conditions, towards a low-cost, rapid, and field-ready assay. A collection of such flow velocity data generates a unique fingerprinting profile for each bacterial species. Support vector machine is utilized to classify the species. At optimized conditions, the training model can predict the species at 93.3% accuracy out of five bacteria: Escherichia coli, Staphylococcus aureus, Salmonella Typhimurium, Enterococcus faecium, and Pseudomonas aeruginosa. Flow rates are monitored for less than 6 s and the sample-to-answer assay time is less than 10 min. The demonstrated method can open a new way of analyzing complex biological and environmental samples in a biomimetic manner with machine learning classification.
Collapse
Affiliation(s)
- Sangsik Kim
- Department of Biosystems Engineering, The University of Arizona, Tucson, AZ, 85721, United States
| | - Min Hee Lee
- Division of Environmental Science and Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Gyeongsangbuk-do, 37673, Republic of Korea
| | - Theanchai Wiwasuku
- Materials Chemistry Research Centre, Department of Chemistry and Centre of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Alexander S Day
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States
| | - Sujittra Youngme
- Materials Chemistry Research Centre, Department of Chemistry and Centre of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Dong Soo Hwang
- Division of Environmental Science and Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Gyeongsangbuk-do, 37673, Republic of Korea.
| | - Jeong-Yeol Yoon
- Department of Biosystems Engineering, The University of Arizona, Tucson, AZ, 85721, United States; Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States.
| |
Collapse
|
20
|
Rager TL, Koepfli C, Khan WA, Ahmed S, Mahmud ZH, Clayton KN. Usability of Rapid Cholera Detection Device (OmniVis) for Water Quality Workers in Bangladesh: Iterative Convergent Mixed Methods Study. J Med Internet Res 2021; 23:e22973. [PMID: 33978590 PMCID: PMC8156127 DOI: 10.2196/22973] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 01/22/2021] [Accepted: 04/04/2021] [Indexed: 01/30/2023] Open
Abstract
BACKGROUND Cholera poses a significant global health burden. In Bangladesh, cholera is endemic and causes more than 100,000 cases each year. Established environmental reservoirs leave millions at risk of infection through the consumption of contaminated water. The Global Task Force for Cholera Control has called for increased environmental surveillance to detect contaminated water sources prior to human infection in an effort to reduce cases and deaths. The OmniVis rapid cholera detection device uses loop-mediated isothermal amplification and particle diffusometry detection methods integrated into a handheld hardware device that attaches to an iPhone 6 to identify and map contaminated water sources. OBJECTIVE The aim of this study was to evaluate the usability of the OmniVis device with targeted end users to advance the iterative prototyping process and ultimately design a device that easily integrates into users' workflow. METHODS Water quality workers were trained to use the device and subsequently completed an independent device trial and usability questionnaire. Pretraining and posttraining knowledge assessments were administered to ensure training quality did not confound trial and questionnaire. RESULTS Device trials identified common user errors and device malfunctions including incorrect test kit insertion and device powering issues. We did not observe meaningful differences in user errors or device malfunctions accumulated per participant across demographic groups. Over 25 trials, the mean time to complete a test was 47 minutes, a significant reduction compared with laboratory protocols, which take approximately 3 days. Overall, participants found the device easy to use and expressed confidence and comfort in using the device independently. CONCLUSIONS These results are used to advance the iterative prototyping process of the OmniVis rapid cholera detection device so it can achieve user uptake, workflow integration, and scale to ultimately impact cholera control and elimination strategies. We hope this methodology will promote robust usability evaluations of rapid pathogen detection technologies in device development.
Collapse
Affiliation(s)
- Theresa L Rager
- Eck Institute for Global Health, University of Notre Dame, Notre Dame, IN, United States
| | - Cristian Koepfli
- Eck Institute for Global Health, University of Notre Dame, Notre Dame, IN, United States
| | - Wasif A Khan
- Infectious Diseases Division, International Centre for Diarrhoeal Disease Research, Bangladesh, Dhaka, Bangladesh
| | - Sabeena Ahmed
- Infectious Diseases Division, International Centre for Diarrhoeal Disease Research, Bangladesh, Dhaka, Bangladesh
| | - Zahid Hayat Mahmud
- Laboratory Sciences and Services Division, International Centre for Diarrhoeal Disease Research, Bangladesh, Dhaka, Bangladesh
| | | |
Collapse
|
21
|
Banik S, Melanthota SK, Arbaaz, Vaz JM, Kadambalithaya VM, Hussain I, Dutta S, Mazumder N. Recent trends in smartphone-based detection for biomedical applications: a review. Anal Bioanal Chem 2021; 413:2389-2406. [PMID: 33586007 PMCID: PMC7882471 DOI: 10.1007/s00216-021-03184-z] [Citation(s) in RCA: 65] [Impact Index Per Article: 21.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 12/14/2020] [Accepted: 01/18/2021] [Indexed: 11/06/2022]
Abstract
Smartphone-based imaging devices (SIDs) have shown to be versatile and have a wide range of biomedical applications. With the increasing demand for high-quality medical services, technological interventions such as portable devices that can be used in remote and resource-less conditions and have an impact on quantity and quality of care. Additionally, smartphone-based devices have shown their application in the field of teleimaging, food technology, education, etc. Depending on the application and imaging capability required, the optical arrangement of the SID varies which enables them to be used in multiple setups like bright-field, fluorescence, dark-field, and multiple arrays with certain changes in their optics and illumination. This comprehensive review discusses the numerous applications and development of SIDs towards histopathological examination, detection of bacteria and viruses, food technology, and routine diagnosis. Smartphone-based devices are complemented with deep learning methods to further increase the efficiency of the devices. Graphical Abstract.
Collapse
Affiliation(s)
- Soumyabrata Banik
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Sindhoora Kaniyala Melanthota
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Arbaaz
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Joel Markus Vaz
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Vishak Madhwaraj Kadambalithaya
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Iftak Hussain
- Center for Healthcare Entrepreneurship, Indian Institute of Technology, Hyderabad, Telangana, 502285, India
| | - Sibasish Dutta
- Department of Physics, Pandit Deendayal Upadhyaya Adarsha Mahavidyalaya (PDUAM), Eraligool, Karimganj, Assam, 788723, India
| | - Nirmal Mazumder
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
| |
Collapse
|
22
|
Komatsu T, Maeda R, Maeki M, Ishida A, Tani H, Tokeshi M. Dip-Type Paper-Based Analytical Device for Straightforward Quantitative Detection without Precise Sample Introduction. ACS Sens 2021; 6:1094-1102. [PMID: 33660502 DOI: 10.1021/acssensors.0c02367] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The development of low-cost, user-friendly paper-based analytical devices (PADs) that can easily measure target chemicals is attracting attention. However, most PADs require manipulation of the sample using sophisticated micropipettes for quantitative analyses, which restricts their user-friendliness. In addition, immobilization of detection molecules to cellulose fibers is essential for achieving good measuring ability as it ensures the homogeneity of color development. Here, we have described a dip-type PAD that does not require pipette manipulation for sample introduction and immobilization of detection molecules to cellulose fibers and its application to ascorbic acid (AA) and pH assays. The PAD consisted of a dipping area and two channels, each with two detection zones. The developed PADs show color distribution in the two detection zones depending on the sample flow from the dipping area. In comparison with a PAD that has one detection zone at the end of the channel, our developed device achieved higher sensitivity (limit of detection (LOD), 0.22 mg/mL) and reproducibility (maximum coefficient of variation (CV), 2.4%) in AA detection. However, in pH detection, the reproducibility of the PAD with one detection zone at the end of the channel (maximum CV, 21%) was worse than that with two zones (maximum CV, 11%). Furthermore, a dipping time over 3 s did not affect color formation or calibration curves in AA detection: LODs at 3 and 30 s dipping time were 18 and 5.8 μg/mL, respectively. The simultaneous determination of AA and pH in various beverages was performed with no significant difference compared to results of the conventional method.
Collapse
Affiliation(s)
- Takeshi Komatsu
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Sapporo 060-8628, Japan
| | - Ryoga Maeda
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Sapporo 060-8628, Japan
| | - Masatoshi Maeki
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Akihiko Ishida
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Hirofumi Tani
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
| | - Manabu Tokeshi
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita, Sapporo 060-8628, Japan
- Innovative Research Centre for Preventive Medical Engineering, Nagoya University, Furo-cho, Chikusa, Nagoya 464-8601, Japan
- Institute of Nano-Life-Systems, Institute of Innovation for Future Society, Nagoya University, Furo-cho,
Chikusa, Nagoya 464-8601, Japan
| |
Collapse
|
23
|
Vinoth R, Nakagawa T, Mathiyarasu J, Mohan AMV. Fully Printed Wearable Microfluidic Devices for High-Throughput Sweat Sampling and Multiplexed Electrochemical Analysis. ACS Sens 2021; 6:1174-1186. [PMID: 33517662 DOI: 10.1021/acssensors.0c02446] [Citation(s) in RCA: 61] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Although the recent advancement in wearable biosensors provides continuous, noninvasive assessment of physiologically relevant chemical markers from human sweat, several bottlenecks still exist for its practical use. There were challenges in developing a multiplexed biosensing system with rapid microfluidic sampling and transport properties, as well as its integration with a portable potentiostat for improved interference-free data collection. Here, we introduce a clean-room free fabrication of wearable microfluidic sensors, using a screen-printed carbon master, for the electrochemical monitoring of sweat biomarkers during exercise activities. The sweat sampling is enhanced by introducing low-dimensional sensing compartments and lowering the hydrophilicity of channel layers via facile silane functionalization. The fluidic channel captures sweat at the inlet and directs the real-time sweat through the active sensing electrodes (within 40 s) for subsequent decoding and selective analyses. For proof of concept, simultaneous amperometric lactate and potentiometric ion sensing (Na+, K+, and pH) are carried out by a miniature circuit board capable of cross-talk-free signal collection and wireless signal transduction characteristics. All of the sensors demonstrated appreciable sensitivity, selectivity, stability, carryover efficiency, and repeatability. The floating potentiometric circuits eliminate the signal interference from the adjacent amperometric transducers. The fully integrated pumpless microfluidic device is mounted on the epidermis and employed for multiplexed real-time decoding of sweat during stationary biking. The regional variations in sweat composition are analyzed by human trials at the underarm and upperback locations. The presented method offers a large-scale fabrication of inexpensive high-throughput wearable sensors for personalized point-of-care and athletic applications.
Collapse
Affiliation(s)
- Rajendran Vinoth
- Electrodics and Electrocatalysis Division, CSIR—Central Electrochemical Research Institute (CECRI), Karaikudi 630003, Tamil Nadu, India
- Academy of Scientific and Innovative Research (AcSIR)—CSIR, Ghaziabad 201002, Uttar Pradesh, India
| | - Tatsuo Nakagawa
- Research & Development Group, Hitachi, Ltd., 1-280 Higashi-koigakubo, Kokubunji-shi, Tokyo1858601, Japan
| | - Jayaraman Mathiyarasu
- Electrodics and Electrocatalysis Division, CSIR—Central Electrochemical Research Institute (CECRI), Karaikudi 630003, Tamil Nadu, India
- Academy of Scientific and Innovative Research (AcSIR)—CSIR, Ghaziabad 201002, Uttar Pradesh, India
| | - A. M. Vinu Mohan
- Electrodics and Electrocatalysis Division, CSIR—Central Electrochemical Research Institute (CECRI), Karaikudi 630003, Tamil Nadu, India
- Academy of Scientific and Innovative Research (AcSIR)—CSIR, Ghaziabad 201002, Uttar Pradesh, India
| |
Collapse
|
24
|
Needs SH, Osborn HMI, Edwards AD. Counting bacteria in microfluidic devices: Smartphone compatible 'dip-and-test' viable cell quantitation using resazurin amplified detection in microliter capillary arrays. J Microbiol Methods 2021; 187:106199. [PMID: 33771524 DOI: 10.1016/j.mimet.2021.106199] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 03/05/2021] [Accepted: 03/05/2021] [Indexed: 11/29/2022]
Abstract
Viable bacterial cell counting is fundamental to analytical microbiology and agar plate colony counting remains common yet laborious and slow. Here, we demonstrate two methods for counting bacteria using commercially available microfluidic devices. We show that accurate viable cell counting is possible using simple and easy 'dip and test' arrays of microcapillaries. Colorimetric and fluorescent growth detection both permit viable cell counting in microcapillaries either by limiting dilution into multiple microfluidic compartments using a single endpoint measurement, or alternatively by quantifying growth kinetics. The microcapillary devices are compatible with conventional 96 well plates and multichannel pipettes, expanding each microplate row into 120 individual 1 or 2 μL samples. At limiting dilution, counting the proportion of positive compartments permitted accurate calculation of gram-negative and gram-positive bacteria (E. coli and S. saprophyticus) at concentrations down to as low as 10 CFU/mL with almost 1:1 agreement with agar plate colony counts over four orders of magnitude. A smartphone camera was sufficient to record endpoint images of resazurin growth detection both colorimetrically and fluorescently. Viable cell counting of E. coli and S. saprophyticus was also possible through recording growth kinetics and determining the time taken to detect resazurin conversion. However, only the limiting dilution method remained consistent in the presence of urine matrix, as some interference in growth rate was observed when bacteria were spiked into higher concentrations of normal urine to simulate urinary tract infection patient samples. However, with the limiting dilution counting method endpoint growth was always detected even in the presence of 90% urine matrix, suggesting that this method might permit bacterial pathogen counting directly in clinical samples without agar plating.
Collapse
Affiliation(s)
- Sarah H Needs
- School of Pharmacy, University of Reading, Whiteknights Campus, Reading RG6 6DX, UK.
| | - Helen M I Osborn
- School of Pharmacy, University of Reading, Whiteknights Campus, Reading RG6 6DX, UK
| | - Alexander D Edwards
- School of Pharmacy, University of Reading, Whiteknights Campus, Reading RG6 6DX, UK; Capillary Film Technology Ltd, Daux Road, Billingshurst RH14 9SJ, UK.
| |
Collapse
|
25
|
Ng JS, Hashimoto M. 3D-PAD: Paper-Based Analytical Devices with Integrated Three-Dimensional Features. BIOSENSORS 2021; 11:84. [PMID: 33802637 PMCID: PMC8002416 DOI: 10.3390/bios11030084] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 02/14/2021] [Accepted: 02/16/2021] [Indexed: 11/16/2022]
Abstract
This paper describes the use of fused deposition modeling (FDM) printing to fabricate paper-based analytical devices (PAD) with three-dimensional (3D) features, which is termed as 3D-PAD. Material depositions followed by heat reflow is a standard approach for the fabrication of PAD. Such devices are primarily two-dimensional (2D) and can hold only a limited amount of liquid samples in the device. This constraint can pose problems when the sample consists of organic solvents that have low interfacial energies with the hydrophobic barriers. To overcome this limitation, we developed a method to fabricate PAD integrated with 3D features (vertical walls as an example) by FDM 3D printing. 3D-PADs were fabricated using two types of thermoplastics. One thermoplastic had a low melting point that formed hydrophobic barriers upon penetration, and another thermoplastic had a high melting point that maintained 3D features on the filter paper without reflowing. We used polycaprolactone (PCL) for the former, and polylactic acid (PLA) for the latter. Both PCL and PLA were printed with FDM without gaps at the interface, and the resulting paper-based devices possessed hydrophobic barriers consisting of PCL seamlessly integrated with vertical features consisting of PLA. We validated the capability of 3D-PAD to hold 30 μL of solvents (ethanol, isopropyl alcohol, and acetone), all of which would not be retained on conventional PADs fabricated with solid wax printers. To highlight the importance of containing an increased amount of liquid samples, a colorimetric assay for the formation of dimethylglyoxime (DMG)-Ni (II) was demonstrated using two volumes (10 μL and 30 μL) of solvent-based dimethylglyoxime (DMG). FDM printing of 3D-PAD enabled the facile construction of 3D structures integrated with PAD, which would find applications in paper-based chemical and biological assays requiring organic solvents.
Collapse
Affiliation(s)
- James S. Ng
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore;
| | - Michinao Hashimoto
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore;
- SUTD-MIT International Design Centre, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore
- Digital Manufacturing and Design Centre, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore
| |
Collapse
|
26
|
Liu Y, Rollins AM, Levenson RM, Fereidouni F, Jenkins MW. Pocket MUSE: an affordable, versatile and high-performance fluorescence microscope using a smartphone. Commun Biol 2021; 4:334. [PMID: 33712728 PMCID: PMC7955119 DOI: 10.1038/s42003-021-01860-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 02/02/2021] [Indexed: 12/11/2022] Open
Abstract
Smartphone microscopes can be useful tools for a broad range of imaging applications. This manuscript demonstrates the first practical implementation of Microscopy with Ultraviolet Surface Excitation (MUSE) in a compact smartphone microscope called Pocket MUSE, resulting in a remarkably effective design. Fabricated with parts from consumer electronics that are readily available at low cost, the small optical module attaches directly over the rear lens in a smartphone. It enables high-quality multichannel fluorescence microscopy with submicron resolution over a 10× equivalent field of view. In addition to the novel optical configuration, Pocket MUSE is compatible with a series of simple, portable, and user-friendly sample preparation strategies that can be directly implemented for various microscopy applications for point-of-care diagnostics, at-home health monitoring, plant biology, STEM education, environmental studies, etc.
Collapse
Affiliation(s)
- Yehe Liu
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Andrew M Rollins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Richard M Levenson
- Department of Pathology and Laboratory Medicine, University of California Davis Medical Center, Sacramento, CA, USA
| | - Farzad Fereidouni
- Department of Pathology and Laboratory Medicine, University of California Davis Medical Center, Sacramento, CA, USA
| | - Michael W Jenkins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
- Department of Pediatrics, Case Western Reserve University, Cleveland, OH, USA.
| |
Collapse
|
27
|
Han X, Liu Y, Yin J, Yue M, Mu Y. Microfluidic devices for multiplexed detection of foodborne pathogens. Food Res Int 2021; 143:110246. [PMID: 33992358 DOI: 10.1016/j.foodres.2021.110246] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 02/02/2021] [Accepted: 02/16/2021] [Indexed: 01/10/2023]
Abstract
The global burden of foodborne diseases is substantial and foodborne pathogens are the major cause for human illnesses. In order to prevent the spread of foodborne pathogens, detection methods are constantly being updated towards rapid, portable, inexpensive, and multiplexed on-site detection. Due to the nature of the small size and low volume, microfluidics has been applied to rapid, time-saving, sensitive, and portable devices to meet the requirements of on-site detection. Simultaneous detection of multiple pathogens is another key parameter to ensure food safety. Multiplexed detection technology, including microfluidic chip design, offers a new opportunity to achieve this goal. In this review, we introduced several sample preparation and corresponding detection methods on microfluidic devices for multiplexed detection of foodborne pathogens. In the sample preparation section, methods of cell capture and enrichment, as well as nucleic acid sample preparation, were described in detail, and in the section of detection methods, amplification, immunoassay, surface plasmon resonance and impedance spectroscopy were exhaustively illustrated. The limitations and advantages of all available experimental options were also summarized and discussed in order to form a comprehensive understanding of cutting-edge technologies and provide a comparative assessment for future investigation and in-field application.
Collapse
Affiliation(s)
- Xiaoying Han
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310023, PR China; College of Life Sciences, Zhejiang University, Hangzhou 310058, PR China
| | - Yuanhui Liu
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310023, PR China; College of Life Sciences, Zhejiang University, Hangzhou 310058, PR China
| | - Juxin Yin
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310023, PR China
| | - Min Yue
- Department of Veterinary Medicine & Institute of Preventive Veterinary Sciences, Zhejiang University College of Animal Sciences, Hangzhou 310058, PR China; State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, National Clinical Research Center for Infectious Diseases, National Medical Center for Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003, PR China; Hainan Institute of Zhejiang University, Sanya 572025, PR China.
| | - Ying Mu
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310023, PR China.
| |
Collapse
|
28
|
Norovirus detection in water samples at the level of single virus copies per microliter using a smartphone-based fluorescence microscope. Nat Protoc 2021; 16:1452-1475. [PMID: 33514945 DOI: 10.1038/s41596-020-00460-7] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 11/05/2020] [Indexed: 11/08/2022]
Abstract
Norovirus is a widespread public health threat and has a very low infectious dose. This protocol presents the extremely sensitive mobile detection of norovirus from water samples using a custom-built smartphone-based fluorescence microscope and a paper microfluidic chip. Antibody-conjugated fluorescent particles are immunoagglutinated and spread over the paper microfluidic chip by capillary action for individual counting using a smartphone-based fluorescence microscope. Smartphone images are analyzed using intensity- and size-based thresholding for the elimination of background noise and autofluorescence as well as for the isolation of immunoagglutinated particles. The resulting pixel counts of particles are correlated with the norovirus concentration of the tested sample. This protocol provides detailed guidelines for the construction and optimization of the smartphone- and paper-based assay. In addition, a 3D-printed enclosure is presented to incorporate all components in a dark environment. On-chip concentration and the assay of higher concentrations are presented to further broaden the assay range. This method is the first to be presented as a highly sensitive mobile platform for norovirus detection using low-cost materials. With all materials and reagents prepared, a single standard assay takes under 20 min. Although the method described is used for detection of norovirus, the same protocol could be adapted for detection of other pathogens by using different antibodies.
Collapse
|
29
|
FEAST of biosensors: Food, environmental and agricultural sensing technologies (FEAST) in North America. Biosens Bioelectron 2021; 178:113011. [PMID: 33517232 DOI: 10.1016/j.bios.2021.113011] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 01/04/2021] [Accepted: 01/16/2021] [Indexed: 02/08/2023]
Abstract
We review the challenges and opportunities for biosensor research in North America aimed to accelerate translational research. We call for platform approaches based on: i) tools that can support interoperability between food, environment and agriculture, ii) open-source tools for analytics, iii) algorithms used for data and information arbitrage, and iv) use-inspired sensor design. We summarize select mobile devices and phone-based biosensors that couple analytical systems with biosensors for improving decision support. Over 100 biosensors developed by labs in North America were analyzed, including lab-based and portable devices. The results of this literature review show that nearly one quarter of the manuscripts focused on fundamental platform development or material characterization. Among the biosensors analyzed for food (post-harvest) or environmental applications, most devices were based on optical transduction (whether a lab assay or portable device). Most biosensors for agricultural applications were based on electrochemical transduction and few utilized a mobile platform. Presently, the FEAST of biosensors has produced a wealth of opportunity but faces a famine of actionable information without a platform for analytics.
Collapse
|
30
|
Han S, Chopra M, Rubino I, Choi HJ. Paper-Based Applications for Bacteria/Virus. Bioanalysis 2021. [DOI: 10.1007/978-981-15-8723-8_7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
31
|
Abstract
Previous studies from our lab have created a simple procedure for single-cell count of bacteria on a paper chip platform using optical detection from a smartphone. The procedure and steps employed are outlined along with the lessons learned and details of certain steps and how the design was optimized. Smartphone optical detection is easy to use, low cost, and potentially field deployable, which can be useful for early and rapid detection of pathogens. Smartphone imaging of a paper microfluidic chip preloaded with antibody-conjugated particles provides an adaptable platform for detection of different bacterial targets. The paper microfluidic chip was fabricated with a multichannel design. Each channel was preloaded with either a negative control of bovine serum albumin (BSA) conjugated particles, anti-Salmonella Typhimurium-conjugated particles with varying amounts (to cover different ranges of assay), or anti-Escherichia coli-conjugated particles. Samples were introduced to the paper microfluidic chip using pipetting. Antigens of Salmonella Typhimurium traveled through the channel by capillary action confined within the paper fibers surrounded by the hydrophobic barrier. The paper channel was observed to act as a filter for unwanted particles and contaminants found in field samples. Serial dilutions of known concentrations of bacterial targets were also tested using this procedure to construct a standard curve prior to the assays. The antibody-conjugated particles were able to immunoagglutinate which was quantified through evaluation of Mie scatter intensity. This Mie scattering was quantified in images taken with a smartphone at an optimized angle and distance. Mie scatter simulation provided a method of optimizing the experimental setup and could translate easily to other types of target sample matrices. A smartphone application was developed to help the user position the smartphone optimally in relation to the paper microfluidic chip. The application integrated both image capturing capability and a simple image processing algorithm that calculated bacteria concentrations. The detection limit was at a single-cell level with a total assay time ranging from 90 to less than 60 s depending on the target.
Collapse
|
32
|
Shen Y, Xu L, Li Y. Biosensors for rapid detection of Salmonella in food: A review. Compr Rev Food Sci Food Saf 2020; 20:149-197. [PMID: 33443806 DOI: 10.1111/1541-4337.12662] [Citation(s) in RCA: 91] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 09/04/2020] [Accepted: 10/01/2020] [Indexed: 12/13/2022]
Abstract
Salmonella is one of the main causes of foodborne infectious diseases, posing a serious threat to public health. It can enter the food supply chain at various stages of production, processing, distribution, and marketing. High prevalence of Salmonella necessitates efficient and effective approaches for its identification, detection, and monitoring at an early stage. Because conventional methods based on plate counting and real-time polymerase chain reaction are time-consuming and laborious, novel rapid detection methods are urgently needed for in-field and on-line applications. Biosensors provide many advantages over conventional laboratory assays in terms of sensitivity, specificity, and accuracy, and show superiority in rapid response and potential portability. They are now recognized as promising alternative tools and one of the most on-site applicable and end user-accessible methods for rapid detection. In recent years, we have witnessed a flourishing of studies in the development of robust and elaborate biosensors for detection of Salmonella in food. This review aims to provide a comprehensive overview on Salmonella biosensors by highlighting different signal-transducing mechanisms (optical, electrochemical, piezoelectric, etc.) and critically analyzing its recent trends, particularly in combination with nanomaterials, microfluidics, portable instruments, and smartphones. Furthermore, current challenges are emphasized and future perspectives are discussed.
Collapse
Affiliation(s)
- Yafang Shen
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China.,Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, Arkansas
| | - Lizhou Xu
- Department of Materials, Imperial College London, London, UK
| | - Yanbin Li
- Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, Arkansas
| |
Collapse
|
33
|
Spence A, Bangay S. Side-Channel Sensing: Exploiting Side-Channels to Extract Information for Medical Diagnostics and Monitoring. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE-JTEHM 2020; 8:4900213. [PMID: 33094036 PMCID: PMC7571867 DOI: 10.1109/jtehm.2020.3028996] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 08/09/2020] [Accepted: 09/27/2020] [Indexed: 11/24/2022]
Abstract
Information within systems can be extracted through side-channels; unintended communication channels that leak information. The concept of side-channel sensing is explored, in which sensor data is analysed in non-trivial ways to recover subtle, hidden or unexpected information. Practical examples of side-channel sensing are well known in domains such as cybersecurity (CYB), but are not formally recognised within the domain of medical diagnostics and monitoring (MDM). This article reviews side-channel usage within CYB and MDM, identifying techniques and methodologies applicable to both domains. We establish a systematic structure for the use of side-channel sensing in MDM that is comparable to existing structures in CYB, and promote cross-domain transferability of knowledge, mindsets, and techniques.
Collapse
Affiliation(s)
- Aaron Spence
- School of Information TechnologyDeakin UniversityGeelongVIC3216Australia
| | - Shaun Bangay
- School of Information TechnologyDeakin UniversityGeelongVIC3216Australia
| |
Collapse
|
34
|
Imanbekova M, Perumal AS, Kheireddine S, Nicolau DV, Wachsmann-Hogiu S. Lensless, reflection-based dark-field microscopy (RDFM) on a CMOS chip. BIOMEDICAL OPTICS EXPRESS 2020; 11:4942-4959. [PMID: 33014592 PMCID: PMC7510856 DOI: 10.1364/boe.394615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 06/02/2020] [Accepted: 06/04/2020] [Indexed: 06/11/2023]
Abstract
We present for the first time a lens-free, oblique illumination imaging platform for on-sensor dark- field microscopy and shadow-based 3D object measurements. It consists of an LED point source that illuminates a 5-megapixel, 1.4 µm pixel size, back-illuminated CMOS sensor at angles between 0° and 90°. Analytes (polystyrene beads, microorganisms, and cells) were placed and imaged directly onto the sensor. The spatial resolution of this imaging system is limited by the pixel size (∼1.4 µm) over the whole area of the sensor (3.6×2.73 mm). We demonstrated two imaging modalities: (i) shadow imaging for estimation of 3D object dimensions (on polystyrene beads and microorganisms) when the illumination angle is between 0° and 85°, and (ii) dark-field imaging, at >85° illumination angles. In dark-field mode, a 3-4 times drop in background intensity and contrast reversal similar to traditional dark-field imaging was observed, due to larger reflection intensities at those angles. With this modality, we were able to detect and analyze morphological features of bacteria and single-celled algae clusters.
Collapse
Affiliation(s)
- Meruyert Imanbekova
- Department of Bioengineering, McGill University, Montreal, Quebec, H3A 0E9, Canada
- Equal contributions
| | | | - Sara Kheireddine
- Department of Bioengineering, McGill University, Montreal, Quebec, H3A 0E9, Canada
| | - Dan V. Nicolau
- Department of Bioengineering, McGill University, Montreal, Quebec, H3A 0E9, Canada
| | | |
Collapse
|
35
|
Tokunaga Y, Yamaguchi N. Rapid quantification of
Escherichia coli
O157
:
H7
in lettuce and beef using an on‐chip staining microfluidic device. J Food Saf 2020. [DOI: 10.1111/jfs.12851] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Yusuke Tokunaga
- Division of Hygienic Chemistry Osaka Institute of Public Health Osaka Japan
| | - Nobuyasu Yamaguchi
- Division of Hygienic Chemistry Osaka Institute of Public Health Osaka Japan
| |
Collapse
|
36
|
Bills MV, Yoon JY. Label-free Mie Scattering Identification of Tumor Tissue Using an Angular Photodiode Array. IEEE SENSORS LETTERS 2020; 4:4500704. [PMID: 33748652 PMCID: PMC7974318 DOI: 10.1109/lsens.2020.3001489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Tumors differ from normal tissues in several meaningful ways including cellular size, morphology, and protein expression, which will accordingly change the refractive index and the size/morphology of cells. There are also important differences in tissue organization and unique tissue specific cell densities. Instead of time-consuming and labor-intensive histology involving the use of a benchtop microscope, a plot of Mie scattering intensities at fixed wavelength against scattering angle, which we referred to as "Mie spectrum," is suggested as an alternative to identify tumor from normal tissues. An angular photodiode array is developed to measure this Mie spectrum with three different light emitting diodes (blue, green and red) as light sources. The resulting Mie spectra show characteristic peaks for rat colonic tissues, and substantial differences can be found between tumor vs. normal tissues. Two peaks were identified at 120° and 150° scattering angles, potentially representing capillaries and colon cells, respectively. Contributions from crypts and goblet cells, represented by the scattering at 140°, were minimal. Substantial differences between tumor and normal tissues were found with 45°-70° light irradiation angles.
Collapse
Affiliation(s)
- Matthew V Bills
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| | - Jeong-Yeol Yoon
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721, USA
| |
Collapse
|
37
|
Rajendran VK, Bakthavathsalam P, Bergquist PL, Sunna A. Smartphone technology facilitates point-of-care nucleic acid diagnosis: a beginner's guide. Crit Rev Clin Lab Sci 2020; 58:77-100. [PMID: 32609551 DOI: 10.1080/10408363.2020.1781779] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
The reliable detection of nucleic acids at low concentrations in clinical samples like blood, urine and saliva, and in food can be achieved by nucleic acid amplification methods. Several portable and hand-held devices have been developed to translate these laboratory-based methods to point-of-care (POC) settings. POC diagnostic devices could potentially play an important role in environmental monitoring, health, and food safety. Use of a smartphone for nucleic acid testing has shown promising progress in endpoint as well as real-time analysis of various disease conditions. The emergence of smartphone-based POC devices together with paper-based sensors, microfluidic chips and digital droplet assays are used currently in many situations to provide quantitative detection of nucleic acid targets. State-of-the-art portable devices are commercially available and rapidly emerging smartphone-based POC devices that allow the performance of laboratory-quality colorimetric, fluorescent and electrochemical detection are described in this review. We present a comprehensive review of smartphone-based POC sensing applications, specifically on microbial diagnostics, assess their performance and propose recommendations for the future.
Collapse
Affiliation(s)
| | - Padmavathy Bakthavathsalam
- School of Chemistry and Australian Centre for Nanomedicine, University of New South Wales, Sydney, Australia
| | - Peter L Bergquist
- Department of Molecular Sciences, Macquarie University, Sydney, Australia.,Department of Molecular Medicine & Pathology, University of Auckland, Auckland, New Zealand.,Biomolecular Discovery Research Centre, Macquarie University, Sydney, Australia
| | - Anwar Sunna
- Department of Molecular Sciences, Macquarie University, Sydney, Australia.,Biomolecular Discovery Research Centre, Macquarie University, Sydney, Australia
| |
Collapse
|
38
|
Zhao Y, Gu H, Li H, Huang L, Cen X. Accuracy improvement of electrochemical whole blood ketone sensor based on HCT compensation algorithm. Electrophoresis 2020; 41:1446-1449. [PMID: 32333412 DOI: 10.1002/elps.201900472] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Revised: 04/11/2020] [Accepted: 04/17/2020] [Indexed: 02/05/2023]
Abstract
In this manuscript, we demonstrated an electrochemical test strip with HCT (hematocrit) compensation algorithm to improve the accuracy of blood ketone sensor. In the conventional electrochemical sensor, the electrochemical current was directly resolved into the concentration value of the determinant without HCT compensation. For lower or higher HCT blood sample, the measured result was inaccurate. In the proposed design, the blood impedance can be measured to estimate the HCT, which was utilized to compensate the electrochemical current to resolve the more accurate concentration of determinant. The practical blood sample tests demonstrated the proposed design can provide more believable and reliable measured result in clinical point-of-care setting.
Collapse
Affiliation(s)
- Ying Zhao
- National Chengdu Center for Safety Evaluation of Drugs, West China Hospital of Sichuan University, Chengdu, P. R. China
| | - Hui Gu
- National Chengdu Center for Safety Evaluation of Drugs, West China Hospital of Sichuan University, Chengdu, P. R. China
| | - Hongchun Li
- National Chengdu Center for Safety Evaluation of Drugs, West China Hospital of Sichuan University, Chengdu, P. R. China
| | - Lei Huang
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Xiaobo Cen
- National Chengdu Center for Safety Evaluation of Drugs, West China Hospital of Sichuan University, Chengdu, P. R. China
| |
Collapse
|
39
|
de Haan K, Ceylan Koydemir H, Rivenson Y, Tseng D, Van Dyne E, Bakic L, Karinca D, Liang K, Ilango M, Gumustekin E, Ozcan A. Automated screening of sickle cells using a smartphone-based microscope and deep learning. NPJ Digit Med 2020; 3:76. [PMID: 32509973 PMCID: PMC7244537 DOI: 10.1038/s41746-020-0282-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 04/28/2020] [Indexed: 12/13/2022] Open
Abstract
Sickle cell disease (SCD) is a major public health priority throughout much of the world, affecting millions of people. In many regions, particularly those in resource-limited settings, SCD is not consistently diagnosed. In Africa, where the majority of SCD patients reside, more than 50% of the 0.2-0.3 million children born with SCD each year will die from it; many of these deaths are in fact preventable with correct diagnosis and treatment. Here, we present a deep learning framework which can perform automatic screening of sickle cells in blood smears using a smartphone microscope. This framework uses two distinct, complementary deep neural networks. The first neural network enhances and standardizes the blood smear images captured by the smartphone microscope, spatially and spectrally matching the image quality of a laboratory-grade benchtop microscope. The second network acts on the output of the first image enhancement neural network and is used to perform the semantic segmentation between healthy and sickle cells within a blood smear. These segmented images are then used to rapidly determine the SCD diagnosis per patient. We blindly tested this mobile sickle cell detection method using blood smears from 96 unique patients (including 32 SCD patients) that were imaged by our smartphone microscope, and achieved ~98% accuracy, with an area-under-the-curve of 0.998. With its high accuracy, this mobile and cost-effective method has the potential to be used as a screening tool for SCD and other blood cell disorders in resource-limited settings.
Collapse
Affiliation(s)
- Kevin de Haan
- Electrical and Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
| | - Hatice Ceylan Koydemir
- Electrical and Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
| | - Yair Rivenson
- Electrical and Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
| | - Derek Tseng
- Electrical and Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
| | - Elizabeth Van Dyne
- Department of Pediatrics, Division of Hematology-Oncology, David Geffen School of Medicine, University of California, Los Angeles, CA 90095 USA
| | - Lissette Bakic
- Department of Pathology and Laboratory Medicine, David Geffen School of Medicine, University of California, Los Angeles, CA 90095 USA
| | - Doruk Karinca
- Department of Computer Science, University of California, Los Angeles, CA 90095 USA
| | - Kyle Liang
- Department of Computer Science, University of California, Los Angeles, CA 90095 USA
| | - Megha Ilango
- Department of Computer Science, University of California, Los Angeles, CA 90095 USA
| | - Esin Gumustekin
- Department of Neuroscience, University of California, Los Angeles, CA 90095 USA
| | - Aydogan Ozcan
- Electrical and Computer Engineering Department, University of California, Los Angeles, CA 90095 USA
- Bioengineering Department, University of California, Los Angeles, CA 90095 USA
- California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095 USA
- Department of Surgery, David Geffen School of Medicine, University of California, Los Angeles, CA 90095 USA
| |
Collapse
|
40
|
Puiu M, Bala C. Microfluidics-integrated biosensing platforms as emergency tools for on-site field detection of foodborne pathogens. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115831] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
41
|
Paper-based point-of-care immunoassays: Recent advances and emerging trends. Biotechnol Adv 2020; 39:107442. [DOI: 10.1016/j.biotechadv.2019.107442] [Citation(s) in RCA: 95] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 07/04/2019] [Accepted: 08/26/2019] [Indexed: 01/23/2023]
|
42
|
Shrivastava S, Trung TQ, Lee NE. Recent progress, challenges, and prospects of fully integrated mobile and wearable point-of-care testing systems for self-testing. Chem Soc Rev 2020; 49:1812-1866. [PMID: 32100760 DOI: 10.1039/c9cs00319c] [Citation(s) in RCA: 217] [Impact Index Per Article: 54.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The rapid growth of research in the areas of chemical and biochemical sensors, lab-on-a-chip, mobile technology, and wearable electronics offers an unprecedented opportunity in the development of mobile and wearable point-of-care testing (POCT) systems for self-testing. Successful implementation of such POCT technologies leads to minimal user intervention during operation to reduce user errors; user-friendly, easy-to-use and simple detection platforms; high diagnostic sensitivity and specificity; immediate clinical assessment; and low manufacturing and consumables costs. In this review, we discuss recent developments in the field of highly integrated mobile and wearable POCT systems. In particular, aspects of sample handling platforms, recognition elements and sensing methods, and new materials for signal transducers and powering devices for integration into mobile or wearable POCT systems will be highlighted. We also summarize current challenges and future prospects for providing personal healthcare with sample-in result-out mobile and wearable POCT.
Collapse
Affiliation(s)
- Sajal Shrivastava
- School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do 16419, Korea.
| | | | | |
Collapse
|
43
|
Solanki S, Pandey CM, Gupta RK, Malhotra BD. Emerging Trends in Microfluidics Based Devices. Biotechnol J 2020; 15:e1900279. [PMID: 32045505 DOI: 10.1002/biot.201900279] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 01/28/2020] [Indexed: 01/03/2023]
Abstract
One of the major challenges for scientists and engineers today is to develop technologies for the improvement of human health in both developed and developing countries. However, the need for cost-effective, high-performance diagnostic techniques is very crucial for providing accessible, affordable, and high-quality healthcare devices. In this context, microfluidic-based devices (MFDs) offer powerful platforms for automation and integration of complex tasks onto a single chip. The distinct advantage of MFDs lies in precise control of the sample quantities and flow rate of samples and reagents that enable quantification and detection of analytes with high resolution and sensitivity. With these excellent properties, microfluidics (MFs) have been used for various applications in healthcare, along with other biological and medical areas. This review focuses on the emerging demands of MFs in different fields such as biomedical diagnostics, environmental analysis, food and agriculture research, etc., in the last three or so years. It also aims to reveal new opportunities in these areas and future prospects of commercial MFDs.
Collapse
Affiliation(s)
- Shipra Solanki
- Department of Biotechnology, Delhi Technological University, Shahbad Daulatpur, Delhi, 110042, India.,Department of Applied Chemistry, Delhi Technological University, Shahbad Daulatpur, Delhi, 110042, India
| | - Chandra M Pandey
- Department of Applied Chemistry, Delhi Technological University, Shahbad Daulatpur, Delhi, 110042, India
| | - Rajinder K Gupta
- Department of Applied Chemistry, Delhi Technological University, Shahbad Daulatpur, Delhi, 110042, India
| | - Bansi D Malhotra
- Department of Biotechnology, Delhi Technological University, Shahbad Daulatpur, Delhi, 110042, India
| |
Collapse
|
44
|
Aydindogan E, Ceylan AE, Timur S. Paper-based colorimetric spot test utilizing smartphone sensing for detection of biomarkers. Talanta 2020; 208:120446. [DOI: 10.1016/j.talanta.2019.120446] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Revised: 10/01/2019] [Accepted: 10/04/2019] [Indexed: 01/27/2023]
|
45
|
Qu Z, Wang K, Alfranca G, de la Fuente JM, Cui D. A plasmonic thermal sensing based portable device for lateral flow assay detection and quantification. NANOSCALE RESEARCH LETTERS 2020; 15:10. [PMID: 31933217 PMCID: PMC6957652 DOI: 10.1186/s11671-019-3240-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Accepted: 12/24/2019] [Indexed: 06/10/2023]
Abstract
Point-of-care testing (POCT) is widely used for early diagnosis and monitoring of diseases. Lateral flow assay (LFA) is a successfully commercial tool for POCT. However, LFA often suffers from a lack of quantification and analytical sensitivity. To solve these drawbacks, we have previously developed a thermal LFA using plasmonic gold nanoparticles for thermal contrast into a portable device. Although this methodology significantly improves the analytical sensitivity compared with conventional visual detection, quantification problems are still remaining. In this study, we optimized the operating conditions for the device using conduction and radiation thermal sensing modes allowing the quantification of LFA. The limit of detection of the strips merely containing nanoparticles was decreased by 5-fold (conduction mode) and 12-fold (radiation mode) compared to traditional visual detection. The effect of the ambient temperature was studied for both methods of detection showing that the radiation mode was more affected by the ambient temperature than the conduction mode. To validate the thermal sensing method, human chorionic gonadotropin (HCG) biomarker was quantified using our LFA strips, obtaining a detection limit of 2.8 mIU/mL when using the radiation method of detection.
Collapse
Affiliation(s)
- Zhuo Qu
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Rd, Shanghai, 200240, China
| | - Kan Wang
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Rd, Shanghai, 200240, China
| | - Gabriel Alfranca
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Rd, Shanghai, 200240, China.
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales Nanomedicina (CIBER-BBN), 50018, Madrid, Spain.
| | - Jesús M de la Fuente
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Rd, Shanghai, 200240, China.
- Instituto de Ciencia de Materiales de Aragón (ICMA), CSIC/Universidad de Zaragoza, C/Pedro Cerbuna 12, 50009, Zaragoza, Spain.
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales Nanomedicina (CIBER-BBN), 50018, Madrid, Spain.
| | - Daxiang Cui
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Rd, Shanghai, 200240, China.
| |
Collapse
|
46
|
Hassan SU, Zhang X. Microfluidics as an Emerging Platform for Tackling Antimicrobial Resistance (AMR): A Review. CURR ANAL CHEM 2020. [DOI: 10.2174/1573411015666181224145845] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Background:
Antimicrobial resistance (AMR) occurs when microbes become resistant to
antibiotics causing complications and limited treatment options. AMR is more significant where antibiotics
use is excessive or abusive and the strains of bacteria become resistant to antibiotic treatments.
Current technologies for bacteria and its resistant strains identification and antimicrobial susceptibility
testing (AST) are mostly central-lab based in hospitals, which normally take days to
weeks to get results. These tools and procedures are expensive, laborious and skills based. There is
an ever-increasing demand for developing point-of-care (POC) diagnostics tools for rapid and near
patient AMR testing. Microfluidics, an important and fundamental technique to develop POC devices,
has been utilized to tackle AMR in healthcare. This review mainly focuses on the current development
in the field of microfluidics for rapid AMR testing.
Method:
Due to the limitations of conventional AMR techniques, microfluidic-based platforms have
been developed for better understandings of bacterial resistance, smart AST and minimum inhibitory
concentration (MIC) testing tools and development of new drugs. This review aims to summarize the
recent development of AST and MIC testing tools in different formats of microfluidics technology.
Results:
Various microfluidics devices have been developed to combat AMR. Miniaturization and
integration of different tools has been attempted to produce handheld or standalone devices for rapid
AMR testing using different formats of microfluidics technology such as active microfluidics, droplet
microfluidics, paper microfluidics and capillary-driven microfluidics.
Conclusion:
Current conventional AMR detection technologies provide time-consuming, costly,
labor-intensive and central lab-based solutions, limiting their applications. Microfluidics has been
developed for decades and the technology has emerged as a powerful tool for POC diagnostics of antimicrobial
resistance in healthcare providing, simple, robust, cost-effective and portable diagnostics.
The success has been reported in research articles; however, the potential of microfluidics technology
in tackling AMR has not been fully achieved in clinical settings.
Collapse
Affiliation(s)
- Sammer-ul Hassan
- Department of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, United Kingdom
| | - Xunli Zhang
- Department of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, United Kingdom
| |
Collapse
|
47
|
Jung Y, Heo Y, Lee JJ, Deering A, Bae E. Smartphone-based lateral flow imaging system for detection of food-borne bacteria E.coli O157:H7. J Microbiol Methods 2020; 168:105800. [DOI: 10.1016/j.mimet.2019.105800] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 12/02/2019] [Accepted: 12/02/2019] [Indexed: 10/25/2022]
|
48
|
Wlodarczyk KL, Hand DP, Maroto-Valer MM. Maskless, rapid manufacturing of glass microfluidic devices using a picosecond pulsed laser. Sci Rep 2019; 9:20215. [PMID: 31882878 PMCID: PMC6934552 DOI: 10.1038/s41598-019-56711-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Accepted: 12/10/2019] [Indexed: 12/20/2022] Open
Abstract
Conventional manufacturing of glass microfluidic devices is a complex, multi-step process that involves a combination of different fabrication techniques, typically photolithography, chemical/dry etching and thermal/anodic bonding. As a result, the process is time-consuming and expensive, in particular when developing microfluidic prototypes or even manufacturing them in low quantity. This report describes a fabrication technique in which a picosecond pulsed laser system is the only tool required to manufacture a microfluidic device from transparent glass substrates. The laser system is used for the generation of microfluidic patterns directly on glass, the drilling of inlet/outlet ports in glass covers, and the bonding of two glass plates together in order to enclose the laser-generated patterns from the top. This method enables the manufacturing of a fully-functional microfluidic device in a few hours, without using any projection masks, dangerous chemicals, and additional expensive tools, e.g., a mask writer or bonding machine. The method allows the fabrication of various types of microfluidic devices, e.g., Hele-Shaw cells and microfluidics comprising complex patterns resembling up-scaled cross-sections of realistic rock samples, suitable for the investigation of CO2 storage, water remediation and hydrocarbon recovery processes. The method also provides a route for embedding small 3D objects inside these devices.
Collapse
Affiliation(s)
- Krystian L Wlodarczyk
- Research Centre for Carbon Solutions (RCCS), Institute of Mechanical, Process and Energy Engineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom. .,Institute of Photonics and Quantum Sciences, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom.
| | - Duncan P Hand
- Institute of Photonics and Quantum Sciences, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom
| | - M Mercedes Maroto-Valer
- Research Centre for Carbon Solutions (RCCS), Institute of Mechanical, Process and Energy Engineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, United Kingdom
| |
Collapse
|
49
|
Lee K, Park H, Baek S, Han S, Kim D, Chung S, Yoon JY, Seo J. Colorimetric array freshness indicator and digital color processing for monitoring the freshness of packaged chicken breast. Food Packag Shelf Life 2019. [DOI: 10.1016/j.fpsl.2019.100408] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
50
|
Kumar S, Nehra M, Mehta J, Dilbaghi N, Marrazza G, Kaushik A. Point-of-Care Strategies for Detection of Waterborne Pathogens. SENSORS (BASEL, SWITZERLAND) 2019; 19:E4476. [PMID: 31623064 PMCID: PMC6833035 DOI: 10.3390/s19204476] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 10/11/2019] [Accepted: 10/13/2019] [Indexed: 12/31/2022]
Abstract
Waterborne diseases that originated due to pathogen microorganisms are emerging as a serious global health concern. Therefore, rapid, accurate, and specific detection of these microorganisms (i.e., bacteria, viruses, protozoa, and parasitic pathogens) in water resources has become a requirement of water quality assessment. Significant research has been conducted to develop rapid, efficient, scalable, and affordable sensing techniques to detect biological contaminants. State-of-the-art technology-assisted smart sensors have improved features (high sensitivity and very low detection limit) and can perform in a real-time manner. However, there is still a need to promote this area of research, keeping global aspects and demand in mind. Keeping this view, this article was designed carefully and critically to explore sensing technologies developed for the detection of biological contaminants. Advancements using paper-based assays, microfluidic platforms, and lateral flow devices are discussed in this report. The emerging recent trends, mainly point-of-care (POC) technologies, of water safety analysis are also discussed here, along with challenges and future prospective applications of these smart sensing technologies for water health diagnostics.
Collapse
Affiliation(s)
- Sandeep Kumar
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India.
| | - Monika Nehra
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India.
| | - Jyotsana Mehta
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India.
| | - Neeraj Dilbaghi
- Department of Bio and Nano Technology, Guru Jambheshwar University of Science and Technology, Hisar-Haryana 125001, India.
| | - Giovanna Marrazza
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence, Italy.
| | - Ajeet Kaushik
- Department of Natural Sciences, Florida Polytechnic University, Lakeland, FL 33805-8531, USA.
| |
Collapse
|