1
|
Naula Duchi EA, Betancourt Cervantes HA, Yañez Espinosa CR, Rodríguez CA, Garza-Castañon LE, Martínez López JI. Particle Tracking and Micromixing Performance Characterization with a Mobile Device. SENSORS (BASEL, SWITZERLAND) 2023; 23:9900. [PMID: 38139748 PMCID: PMC10747875 DOI: 10.3390/s23249900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/05/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
Strategies to stir and mix reagents in microfluid devices have evolved concomitantly with advancements in manufacturing techniques and sensing. While there is a large array of reported designs to combine and homogenize liquids, most of the characterization has been focused on setups with two inlets and one outlet. While this configuration is helpful to directly evaluate the effects of features and parameters on the mixing degree, it does not portray the conditions for experiments that involve more than two substances required to be subsequently combined. In this work, we present a mixing characterization methodology based on particle tracking as an alternative to the most common approach to measure homogeneity using the standard deviation of pixel intensities from a grayscale image. The proposed algorithm is implemented on a free and open-source mobile application (MIQUOD) for Android devices, numerically tested on COMSOL Multiphysics, and experimentally tested on a bidimensional split and recombine micromixer and a three-dimensional micromixer with sinusoidal grooves for different Reynolds numbers and geometrical features for samples with fluids seeded with red, blue, and green microparticles. The application uses concentration field data and particle track data to evaluate up to eleven performance metrics. Furthermore, with the insights from the experimental and numerical data, a mixing index for particles (mp) is proposed to characterize mixing performance for scenarios with multiple input reagents.
Collapse
Affiliation(s)
- Edisson A. Naula Duchi
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey 64849, Mexico; (E.A.N.D.); (H.A.B.C.); (C.R.Y.E.); (C.A.R.); (L.E.G.-C.)
| | - Héctor Andrés Betancourt Cervantes
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey 64849, Mexico; (E.A.N.D.); (H.A.B.C.); (C.R.Y.E.); (C.A.R.); (L.E.G.-C.)
| | - Christian Rodrigo Yañez Espinosa
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey 64849, Mexico; (E.A.N.D.); (H.A.B.C.); (C.R.Y.E.); (C.A.R.); (L.E.G.-C.)
| | - Ciro A. Rodríguez
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey 64849, Mexico; (E.A.N.D.); (H.A.B.C.); (C.R.Y.E.); (C.A.R.); (L.E.G.-C.)
- Laboratorio Nacional de Manufactura Aditiva y Digital MADiT, Apodaca 64629, Mexico
| | - Luis E. Garza-Castañon
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey 64849, Mexico; (E.A.N.D.); (H.A.B.C.); (C.R.Y.E.); (C.A.R.); (L.E.G.-C.)
| | - J. Israel Martínez López
- Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey 64849, Mexico; (E.A.N.D.); (H.A.B.C.); (C.R.Y.E.); (C.A.R.); (L.E.G.-C.)
- Laboratorio Nacional de Manufactura Aditiva y Digital MADiT, Apodaca 64629, Mexico
| |
Collapse
|
2
|
Zhou Z, Chen Y, Zhu S, Liu L, Ni Z, Xiang N. Inertial microfluidics for high-throughput cell analysis and detection: a review. Analyst 2021; 146:6064-6083. [PMID: 34490431 DOI: 10.1039/d1an00983d] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Since it was first proposed in 2007, inertial microfluidics has been extensively studied in terms of theory, design, fabrication, and application. In recent years, with the rapid development of microfabrication technologies, a variety of channel structures that can focus, concentrate, separate, and capture bioparticles or fluids have been designed and manufactured to extend the range of potential biomedical applications of inertial microfluidics. Due to the advantages of high throughput, simplicity, and low device cost, inertial microfluidics is a promising candidate for rapid sample processing, especially for large-volume samples with low-abundance targets. As an approach to cellular sample pretreatment, inertial microfluidics has been widely employed to ensure downstream cell analysis and detection. In this review, a comprehensive summary of the application of inertial microfluidics for high-throughput cell analysis and detection is presented. According to application areas, the recent advances can be sorted into label-free cell mechanical phenotyping, sheathless flow cytometric counting, electrical impedance cytometer, high-throughput cellular image analysis, and other methods. Finally, the challenges and prospects of inertial microfluidics for cell analysis and detection are summarized.
Collapse
Affiliation(s)
- Zheng Zhou
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Yao Chen
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Shu Zhu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Linbo Liu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| |
Collapse
|
3
|
Daguerre H, Solsona M, Cottet J, Gauthier M, Renaud P, Bolopion A. Positional dependence of particles and cells in microfluidic electrical impedance flow cytometry: origin, challenges and opportunities. LAB ON A CHIP 2020; 20:3665-3689. [PMID: 32914827 DOI: 10.1039/d0lc00616e] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Microfluidic electrical impedance flow cytometry is now a well-known and established method for single-cell analysis. Given the richness of the information provided by impedance measurements, this non-invasive and label-free approach can be used in a wide field of applications ranging from simple cell counting to disease diagnostics. One of its major limitations is the variation of the impedance signal with the position of the cell in the sensing area. Indeed, identical particles traveling along different trajectories do not result in the same data. The positional dependence can be considered as a challenge for the accuracy of microfluidic impedance cytometers. On the other hand, it has recently been regarded by several groups as an opportunity to estimate the position of particles in the microchannel and thus take a further step in the logic of integrating sensors in so-called "Lab-on-a-chip" devices. This review provides a comprehensive overview of the physical grounds of the positional dependence of impedance measurements. Then, both the developed strategies to reduce position influence in impedance-based assays and the recent reported technologies exploiting that dependence for the integration of position detection in microfluidic devices are reviewed.
Collapse
Affiliation(s)
- Hugo Daguerre
- FEMTO-ST Institute, CNRS, Univ. Bourgogne Franche-Comté, AS2M Department, 24 rue Alain Savary, F-25000 Besançon, France.
| | | | | | | | | | | |
Collapse
|
4
|
3D particle transport in multichannel microfluidic networks with rough surfaces. Sci Rep 2020; 10:13848. [PMID: 32796948 PMCID: PMC7427810 DOI: 10.1038/s41598-020-70728-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Accepted: 08/03/2020] [Indexed: 12/25/2022] Open
Abstract
The transport of particles and fluids through multichannel microfluidic networks is influenced by details of the channels. Because channels have micro-scale textures and macro-scale geometries, this transport can differ from the case of ideally smooth channels. Surfaces of real channels have irregular boundary conditions to which streamlines adapt and with which particle interact. In low-Reynolds number flows, particles may experience inertial forces that result in trans-streamline movement and the reorganization of particle distributions. Such transport is intrinsically 3D and an accurate measurement must capture movement in all directions. To measure the effects of non-ideal surface textures on particle transport through complex networks, we developed an extended field-of-view 3D macroscope for high-resolution tracking across large volumes ([Formula: see text]) and investigated a model multichannel microfluidic network. A topographical profile of the microfluidic surfaces provided lattice Boltzmann simulations with a detailed feature map to precisely reconstruct the experimental environment. Particle distributions from simulations closely reproduced those observed experimentally and both measurements were sensitive to the effects of surface roughness. Under the conditions studied, inertial focusing organized large particles into an annular distribution that limited their transport throughout the network while small particles were transported uniformly to all regions.
Collapse
|
5
|
Yang Y, Huang HY, Guo CS. Polarization holographic microscope slide for birefringence imaging of anisotropic samples in microfluidics. OPTICS EXPRESS 2020; 28:14762-14773. [PMID: 32403511 DOI: 10.1364/oe.389973] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Accepted: 03/11/2020] [Indexed: 05/27/2023]
Abstract
Birefringence is an important optical property of anisotropic materials arising from anisotropies of tissue microstructures. Birefringence parameters have been found to be important to understand optical anisotropic architecture of many materials and polarization imaging has been applied in many researches in the field of biology and medicine. Here, we propose a scheme to miniaturize a double-channel polarization holographic interferometer optics to create a polarization holographic microscope slide (P-HMS) suitable for integrating with microfluidic lab-on-a-chip (LoC) systems. Based on the P-HMS combined with a simple reconstruction algorithm described in the paper, we can not only simultaneously realize holographic imaging of two orthogonal polarization components of dynamic samples in a microfluidic channel but also quantitative measurement of 2D birefringence information, both including the birefringence phase retardation and optic-axis orientation. This chip interferometer allows for off-axis double-channel polarization digital holographic recording using only a single illumination beam without need of any beam splitter or mirror. Its quasi-common path configuration and self-aligned design also make it tolerant to vibrations and misalignment. This work about the P-HMS could play a positive role in promoting the application of birefringence imaging in microfluidic LoC technology.
Collapse
|
6
|
Arandian A, Bagheri Z, Ehtesabi H, Najafi Nobar S, Aminoroaya N, Samimi A, Latifi H. Optical Imaging Approaches to Monitor Static and Dynamic Cell-on-Chip Platforms: A Tutorial Review. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1900737. [PMID: 31087503 DOI: 10.1002/smll.201900737] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 04/14/2019] [Indexed: 06/09/2023]
Abstract
Miniaturized laboratories on chip platforms play an important role in handling life sciences studies. The platforms may contain static or dynamic biological cells. Examples are a fixed medium of an organ-on-a-chip and individual cells moving in a microfluidic channel, respectively. Due to feasibility of control or investigation and ethical implications of live targets, both static and dynamic cell-on-chip platforms promise various applications in biology. To extract necessary information from the experiments, the demand for direct monitoring is rapidly increasing. Among different microscopy methods, optical imaging is a straightforward choice. Considering light interaction with biological agents, imaging signals may be generated as a result of scattering or emission effects from a sample. Thus, optical imaging techniques could be categorized into scattering-based and emission-based techniques. In this review, various optical imaging approaches used in monitoring static and dynamic platforms are introduced along with their optical systems, advantages, challenges, and applications. This review may help biologists to find a suitable imaging technique for different cell-on-chip studies and might also be useful for the people who are going to develop optical imaging systems in life sciences studies.
Collapse
Affiliation(s)
- Alireza Arandian
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Zeinab Bagheri
- Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Hamide Ehtesabi
- Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Shima Najafi Nobar
- Faculty of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, 1969764499, Iran
| | - Neda Aminoroaya
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Ashkan Samimi
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Hamid Latifi
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, 1983969411, Iran
- Department of Physics, Shahid Beheshti University, Tehran, 1983969411, Iran
| |
Collapse
|
7
|
Reale R, De Ninno A, Businaro L, Bisegna P, Caselli F. High-throughput electrical position detection of single flowing particles/cells with non-spherical shape. LAB ON A CHIP 2019; 19:1818-1827. [PMID: 30997463 DOI: 10.1039/c9lc00071b] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
We present an innovative impedance cytometer for the measurement of the cross-sectional position of single particles or cells flowing in a microchannel. As predicted by numerical simulations and experimentally validated, the proposed approach is applicable to particles/cells with either spherical or non-spherical shape. In particular, the optics-free high-throughput position detection of individual flowing red blood cells (RBCs) is demonstrated and applied to monitor RBCs hydrodynamic focusing under different sheath flow conditions. Moreover, the device provides multiparametric information useful for lab-on-a-chip applications, including particle inter-arrival times and velocity profile, as well as RBCs mean corpuscular volume, distribution width and electrical opacity.
Collapse
Affiliation(s)
- Riccardo Reale
- Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, 00133 Rome, Italy.
| | | | | | | | | |
Collapse
|
8
|
Solsona M, Westerbeek EY, Bomer JG, Olthuis W, van den Berg A. Gradient in the electric field for particle position detection in microfluidic channels. LAB ON A CHIP 2019; 19:1054-1059. [PMID: 30768116 DOI: 10.1039/c8lc01333k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In this work, a new method to track particles in microfluidic channels is presented. Particle position tracking in microfluidic systems is crucial to characterize sorting systems or to improve the analysis of cells in impedance flow cytometry studies. By developing an electric field gradient in a two parallel electrode array the position of the particles can be tracked in one axis by impedance analysis. This method can track the particle's position at lower frequencies and measure the conductivity of the system at higher frequencies. A 3-D simulation was performed showing particle position detection and conductivity analysis. To experimentally validate the technique, a microfluidic chip that develops a gradient in the electric field was fabricated and used to detect the position of polystyrene particles in one axis and measure their conductivity at low and high frequencies, respectively.
Collapse
Affiliation(s)
- Miguel Solsona
- BIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, University of Twente, Drienerlolaan 5, Enschede, The Netherlands.
| | | | | | | | | |
Collapse
|
9
|
Morley ST, Walsh MT, Newport DT. Opportunities for Studying the Hydrodynamic Context for Breast Cancer Cell Spread Through Lymph Flow. Lymphat Res Biol 2017; 15:204-219. [PMID: 28749743 DOI: 10.1089/lrb.2017.0005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The lymphatic system serves as the primary route for the metastatic spread of breast cancer cells (BCCs). A scarcity of information exists with regard to the advection of BCCs in lymph flow and a fundamental understanding of the response of BCCs to the forces in the lymphatics needs to be established. This review summarizes the flow environment metastatic BCCs are exposed to in the lymphatics. Special attention is paid to the behavior of cells/particles in microflows in an attempt to elucidate the behavior of BCCs under lymph flow conditions (Reynolds number <1).
Collapse
Affiliation(s)
- Sinéad T Morley
- 1 Faculty of Science & Engineering, School of Engineering, Bernal Institute, University of Limerick , Limerick, Ireland
| | - Michael T Walsh
- 1 Faculty of Science & Engineering, School of Engineering, Bernal Institute, University of Limerick , Limerick, Ireland .,2 Health Research Institute, University of Limerick , Limerick, Ireland
| | - David T Newport
- 1 Faculty of Science & Engineering, School of Engineering, Bernal Institute, University of Limerick , Limerick, Ireland
| |
Collapse
|
10
|
Morley ST, Newport DT, Walsh MT. Towards the prediction of flow-induced shear stress distributions experienced by breast cancer cells in the lymphatics. Biomech Model Mechanobiol 2017; 16:2051-2062. [PMID: 28741084 DOI: 10.1007/s10237-017-0937-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Accepted: 07/11/2017] [Indexed: 01/28/2023]
Abstract
Tumour metastasis in the lymphatics is a crucial step in the progression of breast cancer. The dynamics by which breast cancer cells (BCCs) travel in the lymphatics remains poorly understood. The goal of this work is to develop a model capable of predicting the shear stresses metastasising BCCs experience using numerical and experimental techniques. This paper models the fluidic transport of large particles ([Formula: see text] where [Formula: see text] is the particle diameter and W is the channel width) subjected to lymphatic flow conditions ([Formula: see text]), in a [Formula: see text] microchannel. The feasibility of using the dynamic fluid body interaction (DFBI) method to predict particle motion was assessed, and particle tracking experiments were performed. The experiments found that particle translational velocity decreased from the undisturbed fluid velocity with increasing particle size (5-14% velocity lag for [Formula: see text]). DFBI simulations were found to better predict particle behaviour than theoretical predictions; however, mesh restrictions in the near-wall region ([Formula: see text]) result in computationally expensive models. The simulations were in good agreement with the experiments ([Formula: see text] difference) across the channel ([Formula: see text]), with differences up to 25% in the near-wall region. Particles experience a range of shear stresses (0.002-0.12 Pa) and spatial shear gradients ([Formula: see text]) depending on their size and radial position. The predicted shear gradients are far in excess of values associated with BCC apoptosis ([Formula: see text]). Increasing our understanding of the shear stress magnitudes and gradients experienced by BCCs could be leveraged to elucidate whether a particular BCC size or location exists that encourages metastasis within the lymphatics.
Collapse
Affiliation(s)
- S T Morley
- School of Engineering, Bernal Institute, University of Limerick, Limerick, Ireland
| | - D T Newport
- School of Engineering, Bernal Institute, University of Limerick, Limerick, Ireland
| | - M T Walsh
- School of Engineering, Bernal Institute, University of Limerick, Limerick, Ireland. .,Health Research Institute, University of Limerick, Limerick, Ireland.
| |
Collapse
|
11
|
Morley ST, Walsh MT, Newport DT. The advection of microparticles, MCF-7 and MDA-MB-231 breast cancer cells in response to very low Reynolds numbers. BIOMICROFLUIDICS 2017; 11:034105. [PMID: 28529671 PMCID: PMC5419862 DOI: 10.1063/1.4983149] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Accepted: 04/26/2017] [Indexed: 05/05/2023]
Abstract
The lymphatic system is an extensive vascular network that serves as the primary route for the metastatic spread of breast cancer cells (BCCs). The dynamics by which BCCs travel in the lymphatics to distant sites, and eventually establish metastatic tumors, remain poorly understood. Particle tracking techniques were employed to analyze the behavior of MCF-7 and MDA-MB-231 BCCs which were exposed to lymphatic flow conditions in a 100 μm square microchannel. The behavior of the BCCs was compared to rigid particles of various diameters (η = dp/H= 0.05-0.32) that have been used to simulate cell flow in lymph. Parabolic velocity profiles were recorded for all particle sizes. All particles were found to lag the fluid velocity, the larger the particle the slower its velocity relative to the local flow (5%-15% velocity lag recorded). A distinct difference between the behavior of BCCs and particles was recorded. The BCCs travelled approximately 40% slower than the undisturbed flow, indicating that morphology and size affects their response to lymphatic flow conditions (Re < 1). BCCs adhered together, forming aggregates whose behavior was irregular. At lymphatic flow rates, MCF-7s were distributed uniformly across the channel in comparison to the MDA-MB-231 cells which travelled in the central region (88% of cells found within 0.35 ≤ W ≤ 0.64), indicating that metastatic MDA-MB-231 cells are subjected to a lower range of shear stresses in vivo. This suggests that both size and deformability need to be considered when modelling BCC behavior in the lymphatics. This finding will inform the development of in vitro lymphatic flow and metastasis models.
Collapse
Affiliation(s)
- Sinéad T Morley
- School of Engineering, Bernal Institute, Faculty of Science and Engineering, University of Limerick, Limerick, Ireland
| | | | - David T Newport
- School of Engineering, Bernal Institute, Faculty of Science and Engineering, University of Limerick, Limerick, Ireland
| |
Collapse
|
12
|
Campos Marin A, Grossi T, Bianchi E, Dubini G, Lacroix D. 2D µ-Particle Image Velocimetry and Computational Fluid Dynamics Study Within a 3D Porous Scaffold. Ann Biomed Eng 2016; 45:1341-1351. [PMID: 27957607 PMCID: PMC5397455 DOI: 10.1007/s10439-016-1772-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Accepted: 12/02/2016] [Indexed: 01/14/2023]
Abstract
Transport properties of 3D scaffolds under fluid flow are critical for tissue development. Computational fluid dynamics (CFD) models can resolve 3D flows and nutrient concentrations in bioreactors at the scaffold-pore scale with high resolution. However, CFD models can be formulated based on assumptions and simplifications. μ-Particle image velocimetry (PIV) measurements should be performed to improve the reliability and predictive power of such models. Nevertheless, measuring fluid flow velocities within 3D scaffolds is challenging. The aim of this study was to develop a μPIV approach to allow the extraction of velocity fields from a 3D additive manufacturing scaffold using a conventional 2D μPIV system. The μ-computed tomography scaffold geometry was included in a CFD model where perfusion conditions were simulated. Good agreement was found between velocity profiles from measurements and computational results. Maximum velocities were found at the centre of the pore using both techniques with a difference of 12% which was expected according to the accuracy of the μPIV system. However, significant differences in terms of velocity magnitude were found near scaffold substrate due to scaffold brightness which affected the μPIV measurements. As a result, the limitations of the μPIV system only permits a partial validation of the CFD model. Nevertheless, the combination of both techniques allowed a detailed description of velocity maps within a 3D scaffold which is crucial to determine the optimal cell and nutrient transport properties.
Collapse
Affiliation(s)
- A Campos Marin
- Insigneo Institute for in silico Medicine, Department of Mechanical Engineering, University of Sheffield, Pam Liversidge Building, Mappin Street, Sheffield, S1 3JD, UK
| | - T Grossi
- Laboratory of Biological Structure Mechanics, Politecnico di Milano, Milan, Italy
| | - E Bianchi
- Laboratory of Biological Structure Mechanics, Politecnico di Milano, Milan, Italy
| | - G Dubini
- Laboratory of Biological Structure Mechanics, Politecnico di Milano, Milan, Italy
| | - D Lacroix
- Insigneo Institute for in silico Medicine, Department of Mechanical Engineering, University of Sheffield, Pam Liversidge Building, Mappin Street, Sheffield, S1 3JD, UK.
| |
Collapse
|