1
|
Xu X, Valavanis D, Ciocci P, Confederat S, Marcuccio F, Lemineur JF, Actis P, Kanoufi F, Unwin PR. The New Era of High-Throughput Nanoelectrochemistry. Anal Chem 2023; 95:319-356. [PMID: 36625121 PMCID: PMC9835065 DOI: 10.1021/acs.analchem.2c05105] [Citation(s) in RCA: 34] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Indexed: 01/11/2023]
Affiliation(s)
- Xiangdong Xu
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, U.K.
| | | | - Paolo Ciocci
- Université
Paris Cité, ITODYS, CNRS, F-75013 Paris, France
| | - Samuel Confederat
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, U.K.
- Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, U.K.
| | - Fabio Marcuccio
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, U.K.
- Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, U.K.
- Faculty
of Medicine, Imperial College London, London SW7 2AZ, United Kingdom
| | | | - Paolo Actis
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, U.K.
- Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, U.K.
| | | | - Patrick R. Unwin
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, U.K.
| |
Collapse
|
2
|
Caniglia G, Tezcan G, Meloni GN, Unwin PR, Kranz C. Probing and Visualizing Interfacial Charge at Surfaces in Aqueous Solution. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2022; 15:247-267. [PMID: 35259914 DOI: 10.1146/annurev-anchem-121521-122615] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Surface charge density and distribution play an important role in almost all interfacial processes, influencing, for example, adsorption, colloidal stability, functional material activity, electrochemical processes, corrosion, nanoparticle toxicity, and cellular processes such as signaling, absorption, and adhesion. Understanding the heterogeneity in, and distribution of, surface and interfacial charge is key to elucidating the mechanisms underlying reactivity, the stability of materials, and biophysical processes. Atomic force microscopy (AFM) and scanning ion conductance microscopy (SICM) are highly suitable for probing the material/electrolyte interface at the nanoscale through recent advances in probe design, significant instrumental (hardware and software) developments, and the evolution of multifunctional imaging protocols. Here, we assess the capability of AFM and SICM for surface charge mapping, covering the basic underpinning principles alongside experimental considerations. We illustrate and compare the use of AFM and SICM for visualizing surface and interfacial charge with examples from materials science, geochemistry, and the life sciences.
Collapse
Affiliation(s)
- Giada Caniglia
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Ulm, Germany;
| | - Gözde Tezcan
- Department of Chemistry, University of Warwick, Coventry, United Kingdom;
| | - Gabriel N Meloni
- Department of Chemistry, University of Warwick, Coventry, United Kingdom;
| | - Patrick R Unwin
- Department of Chemistry, University of Warwick, Coventry, United Kingdom;
| | - Christine Kranz
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Ulm, Germany;
| |
Collapse
|
3
|
McPherson IJ, Brown P, Meloni GN, Unwin PR. Visualization of Ion Fluxes in Nanopipettes: Detection and Analysis of Electro-osmosis of the Second Kind. Anal Chem 2021; 93:16302-16307. [PMID: 34846865 DOI: 10.1021/acs.analchem.1c02371] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Nanopipettes are finding increasing use as nano "test tubes", with reactions triggered through application of an electrochemical potential between electrodes in the nanopipette and a bathing solution (bath). Key to this application is an understanding of how the applied potential induces mixing of the reagents from the nanopipette and the bath. Here, we demonstrate a laser scanning confocal microscope (LSCM) approach to tracking the ingress of dye into a nanopipette (20-50 nm diameter end opening). We examine the case of dianionic fluorescein under alkaline conditions (pH 11) and large applied tip potentials (±10 V), with respect to the bath, and surprisingly find that dye ingress from the bath into the nanopipette is not observed under either sign of potential. Finite element method (FEM) simulations indicate this is due to the dominance of electro-osmosis in mass transport, with electro-osmotic flow in the conventional direction at +10 V and electro-osmosis of the second kind acting in the same direction at -10 V, caused by the formation of significant space charge in the center of the orifice. The results highlight the significant deviation in mass transport behavior that emerges at the nanoscale and the utility of the combined LSCM and FEM approach in deepening understanding, which in turn should promote new applications of nanopipettes.
Collapse
Affiliation(s)
- Ian J McPherson
- Department of Chemistry, University of Warwick, Gibbet Hill, Coventry CV4 7AL, United Kingdom
| | - Peter Brown
- Department of Chemistry, University of Warwick, Gibbet Hill, Coventry CV4 7AL, United Kingdom
| | - Gabriel N Meloni
- Department of Chemistry, University of Warwick, Gibbet Hill, Coventry CV4 7AL, United Kingdom
| | - Patrick R Unwin
- Department of Chemistry, University of Warwick, Gibbet Hill, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
4
|
Zhang D, Zhang X. Bioinspired Solid-State Nanochannel Sensors: From Ionic Current Signals, Current, and Fluorescence Dual Signals to Faraday Current Signals. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2100495. [PMID: 34117705 DOI: 10.1002/smll.202100495] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 02/21/2021] [Indexed: 06/12/2023]
Abstract
Inspired from bioprotein channels of living organisms, constructing "abiotic" analogues, solid-state nanochannels, to achieve "smart" sensing towards various targets, is highly seductive. When encountered with certain stimuli, dynamic switch of terminal modified probes in terms of surface charge, conformation, fluorescence property, electric potential as well as wettability can be monitored via transmembrane ionic current, fluorescence intensity, faraday current signals of nanochannels and so on. Herein, the modification methodologies of nanochannels and targets-detecting application are summarized in ions, small molecules, as well as biomolecules, and systematically reviewed are the nanochannel-based detection means including 1) by transmembrane current signals; 2) by the coordination of current- and fluorescence-dual signals; 3) by faraday current signals from nanochannel-based electrode. The coordination of current and fluorescence dual signals offers great benefits for synchronous temporal and spatial monitoring. Faraday signals enable the nanoelectrode to monitor both redox and non-redox components. Notably, by incorporation with confined effect of tip region of a needle-like nanopipette, glorious in-vivo monitoring is conferred on the nanopipette detector at high temporal-spatial resolution. In addition, some outlooks for future application in reliable practical samples analysis and leading research endeavors in the related fantastic fields are provided.
Collapse
Affiliation(s)
- Dan Zhang
- Cancer Centre and Centre of Reproduction, Development and Aging, Faculty of Health Sciences, University of Macau, Macau, SAR, 999078, China
| | - Xuanjun Zhang
- Cancer Centre and Centre of Reproduction, Development and Aging, Faculty of Health Sciences, University of Macau, Macau, SAR, 999078, China
| |
Collapse
|
5
|
Teahan J, Perry D, Chen B, McPherson IJ, Meloni GN, Unwin PR. Scanning Ion Conductance Microscopy: Surface Charge Effects on Electroosmotic Flow Delivery from a Nanopipette. Anal Chem 2021; 93:12281-12288. [PMID: 34460243 DOI: 10.1021/acs.analchem.1c01868] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Scanning ion conductance microscopy (SICM) is a powerful and versatile technique that allows an increasingly wide range of interfacial properties and processes to be studied. SICM employs a nanopipette tip that contains electrolyte solution and a quasi-reference counter electrode (QRCE), to which a potential is applied with respect to a QRCE in a bathing solution, in which the tip is placed. The work herein considers the potential-controlled delivery of uncharged electroactive molecules (solute) from an SICM tip to a working electrode substrate to determine the effect of the substrate on electroosmotic flow (EOF). Specifically, the local delivery of hydroquinone from the tip to a carbon fiber ultramicroelectrode (CF UME) provides a means of quantifying the rate of mass transport from the nanopipette and mapping electroactivity via the CF UME current response for hydroquinone oxidation to benzoquinone. EOF, and therefore species delivery, has a particularly strong dependence on the charge of the substrate surface at close nanopipette-substrate surface separations, with implications for retaining neutral solute within the tip predelivery and for the delivery process itself, both controlled via the applied tip potential. Finite element method (FEM) simulations of mass transport and reactivity are used to explain the experimental observations and identify the nature of EOF, including unusual flow patterns under certain conditions. The combination of experimental results with FEM simulations provides new insights on mass transport in SICM that will enhance quantitative applications and enable new possibilities for the use of nanopipettes for local delivery.
Collapse
Affiliation(s)
- James Teahan
- MAS Centre for Doctoral Training, University of Warwick, Coventry CV4 7AL, United Kingdom.,Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Baoping Chen
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Ian J McPherson
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Gabriel N Meloni
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R Unwin
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
6
|
Sato K, Sato F, Kumano M, Kamijo T, Sato T, Zhou Y, Korchev Y, Fukuma T, Fujimura T, Takahashi Y. Electrochemical Quantitative Evaluation of the Surface Charge of a Poly(1‐Vinylimidazole) Multilayer Film and Application to Nanopore pH Sensor. ELECTROANAL 2021. [DOI: 10.1002/elan.202100041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Katsuhiko Sato
- Faculty of Pharmaceutical Science Tohoku Medical and Pharmaceutical University 4-4-1 Komatsushima, Aoba Sendai Miyagi 981-8558 Japan
- Department of Creative Engineering National Institute of Technology Tsuruoka College 104 Sawada, Inooka Tsuruoka Yamagata 997-8511 Japan
| | - Fumiya Sato
- Graduate School of Pharmaceutical Sciences Tohoku University 6-3 Aoba, Aramaki, Aoba-ku Sendai 980-8578 Japan
| | - Masayuki Kumano
- Graduate School of Pharmaceutical Sciences Tohoku University 6-3 Aoba, Aramaki, Aoba-ku Sendai 980-8578 Japan
| | - Toshio Kamijo
- Department of Creative Engineering National Institute of Technology Tsuruoka College 104 Sawada, Inooka Tsuruoka Yamagata 997-8511 Japan
| | - Takaya Sato
- Department of Creative Engineering National Institute of Technology Tsuruoka College 104 Sawada, Inooka Tsuruoka Yamagata 997-8511 Japan
| | - Yuanshu Zhou
- Nano Life Science Institute (WPI-NanoLSI) Kanazawa University, Kakuma-machi Kanazawa 920-1192 Japan
| | - Yuri Korchev
- Nano Life Science Institute (WPI-NanoLSI) Kanazawa University, Kakuma-machi Kanazawa 920-1192 Japan
- Imperial College London Department of Medicine W12 0NN London United Kingdom
| | - Takeshi Fukuma
- Nano Life Science Institute (WPI-NanoLSI) Kanazawa University, Kakuma-machi Kanazawa 920-1192 Japan
| | - Tsutomu Fujimura
- Faculty of Pharmaceutical Science Tohoku Medical and Pharmaceutical University 4-4-1 Komatsushima, Aoba Sendai Miyagi 981-8558 Japan
| | - Yasufumi Takahashi
- Nano Life Science Institute (WPI-NanoLSI) Kanazawa University, Kakuma-machi Kanazawa 920-1192 Japan
- Precursory Research for Embryonic Science and Technology (PRESTO) Japan Science and Technology Agency (JST) Saitama 332-0012 Japan
| |
Collapse
|
7
|
Liu X, Liu C, Yang J, Zhang R, Zeng Q, Wang L. Detection and FEM studies of dichromate (Cr2O72−) by allyltriethoxysilane modified nanochannel. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.113818] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
8
|
Huang L, Wang Z, Cupp-Sutton KA, Smith K, Wu S. Spray-Capillary: An Electrospray-Assisted Device for Quantitative Ultralow-Volume Sample Handling. Anal Chem 2020; 92:640-646. [PMID: 31793760 PMCID: PMC7558432 DOI: 10.1021/acs.analchem.9b04131] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
The analysis of low-volume samples provides valuable insight into complex biological systems. However, the proteomic and metabolomic analysis of low-volume samples remains challenging due to the lack of simple, efficient, and reproducible microsampling techniques. We have developed an electrospray-assisted device for quantitative low-volume sample extraction, referred to here as "Spray-Capillary". Stable electrospray was achieved through a chemically etched tip from a long (e.g., 50 cm) capillary with a conductive sheath flow. This electrospray provided the driving force to quantitatively draw low-volume samples into the capillary. We evaluated the precision and accuracy of sample injection volumes using our spray-capillary as the electrospray voltage, capillary ID, and column length were varied. Our results demonstrate that spray-capillary allows for reproducible and quantitative microsampling with low injection flow rates (as low as 15 pL/s). Furthermore, spray-capillary can be directly coupled with capillary zone electrophoresis (CZE) for separation. Overall, spray-capillary is a simple microsampling device that holds great potential for high-throughput quantitative omics analysis of ultralow-volume samples.
Collapse
Affiliation(s)
- Lushuang Huang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Zhe Wang
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Kellye A. Cupp-Sutton
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| | - Kenneth Smith
- Department of Arthritis and Clinical Immunology, Oklahoma Medical Research Foundation, Oklahoma City, Oklahoma 73104, United States
| | - Si Wu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, Oklahoma 73019, United States
| |
Collapse
|
9
|
Chen B, Perry D, Page A, Kang M, Unwin PR. Scanning Ion Conductance Microscopy: Quantitative Nanopipette Delivery-Substrate Electrode Collection Measurements and Mapping. Anal Chem 2019; 91:2516-2524. [PMID: 30608117 DOI: 10.1021/acs.analchem.8b05449] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Scanning ion conductance microscopy (SICM) is becoming a powerful multifunctional tool for probing and analyzing surfaces and interfaces. This work outlines methodology for the quantitative controlled delivery of ionic redox-active molecules from a nanopipette to a substrate electrode, with a high degree of spatial and temporal precision. Through control of the SICM bias applied between a quasi-reference counter electrode (QRCE) in the SICM nanopipette probe and a similar electrode in bulk solution, it is shown that ionic redox species can be held inside the nanopipette, and then pulse-delivered to a defined region of a substrate positioned beneath the nanopipette. A self-referencing hopping mode imaging protocol is implemented, where reagent is released in bulk solution (reference measurement) and near the substrate surface at each pixel in an image, with the tip and substrate currents measured throughout. Analysis of the tip and substrate current data provides an improved understanding of mass transport and nanoscale delivery in SICM and a new means of synchronously mapping electrode reactivity, surface topography, and charge. Experiments on Ru(NH3)63+ reduction to Ru(NH3)62+ and dopamine oxidation in aqueous solution at a carbon fiber ultramicroelectrode (UME), used as the substrate, illustrate these aspects. Finite element method (FEM) modeling provides quantitative understanding of molecular delivery in SICM. The approach outlined constitutes a new methodology for electrode mapping and provides improved insights on the use of SICM for controlled delivery to interfaces generally.
Collapse
|
10
|
Wang Y, Shan X, Tao N. Emerging tools for studying single entity electrochemistry. Faraday Discuss 2018; 193:9-39. [PMID: 27722354 DOI: 10.1039/c6fd00180g] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Electrochemistry studies charge transfer and related processes at various microscopic structures (atomic steps, islands, pits and kinks on electrodes), and mesoscopic materials (nanoparticles, nanowires, viruses, vesicles and cells) made by nature and humans, involving ions and molecules. The traditional approach measures averaged electrochemical quantities of a large ensemble of these individual entities, including the microstructures, mesoscopic materials, ions and molecules. There is a need to develop tools to study single entities because a real system is usually heterogeneous, e.g., containing nanoparticles with different sizes and shapes. Even in the case of "homogeneous" molecules, they bind to different microscopic structures of an electrode, assume different conformations and fluctuate over time, leading to heterogeneous reactions. Here we highlight some emerging tools for studying single entity electrochemistry, discuss their strengths and weaknesses, and provide personal views on the need for tools with new capabilities for further advancing single entity electrochemistry.
Collapse
Affiliation(s)
- Yixian Wang
- Center for Biosensors and Bioelectronics, Biodesign Institute and School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287, USA.
| | - Xiaonan Shan
- Center for Biosensors and Bioelectronics, Biodesign Institute and School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287, USA.
| | - Nongjian Tao
- Center for Biosensors and Bioelectronics, Biodesign Institute and School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287, USA. and State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| |
Collapse
|
11
|
Kirkpatrick DC, McKinney CJ, Manis PB, Wightman RM. Expanding neurochemical investigations with multi-modal recording: simultaneous fast-scan cyclic voltammetry, iontophoresis, and patch clamp measurements. Analyst 2018; 141:4902-11. [PMID: 27314130 DOI: 10.1039/c6an00933f] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Multi-modal recording describes the simultaneous collection of information across distinct domains. Compared to isolated measurements, such studies can more easily determine relationships between varieties of phenomena. This is useful for neurochemical investigations which examine cellular activity in response to changes in the local chemical environment. In this study, we demonstrate a method to perform simultaneous patch clamp measurements with fast-scan cyclic voltammetry (FSCV) using optically isolated instrumentation. A model circuit simulating concurrent measurements was used to predict the electrical interference between instruments. No significant impact was anticipated between methods, and predictions were largely confirmed experimentally. One exception was due to capacitive coupling of the FSCV potential waveform into the patch clamp amplifier. However, capacitive transients measured in whole-cell current clamp recordings were well below the level of biological signals, which allowed the activity of cells to be easily determined. Next, the activity of medium spiny neurons (MSNs) was examined in the presence of an FSCV electrode to determine how the exogenous potential impacted nearby cells. The activities of both resting and active MSNs were unaffected by the FSCV waveform. Additionally, application of an iontophoretic current, used to locally deliver drugs and other neurochemicals, did not affect neighboring cells. Finally, MSN activity was monitored during iontophoretic delivery of glutamate, an excitatory neurotransmitter. Membrane depolarization and cell firing were observed concurrently with chemical changes around the cell resulting from delivery. In all, we show how combined electrophysiological and electrochemical measurements can relate information between domains and increase the power of neurochemical investigations.
Collapse
Affiliation(s)
- D C Kirkpatrick
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, USA.
| | - C J McKinney
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, USA.
| | - P B Manis
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA and The Curriculum of Neurobiology, University of North Carolina, Chapel Hill, NC, USA and Department of Cell Biology and Physiology, University of North Carolina, Chapel Hill, NC, USA
| | - R M Wightman
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, USA. and Neuroscience Center, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3290, USA
| |
Collapse
|
12
|
Advances and Perspectives in Chemical Imaging in Cellular Environments Using Electrochemical Methods. CHEMOSENSORS 2018. [DOI: 10.3390/chemosensors6020024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
13
|
Ion concentration in micro and nanoscale electrospray emitters. Anal Bioanal Chem 2018; 410:3639-3648. [PMID: 29704029 DOI: 10.1007/s00216-018-1043-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2018] [Revised: 03/19/2018] [Accepted: 03/22/2018] [Indexed: 10/17/2022]
Abstract
Solution-phase ion transport during electrospray has been characterized for nanopipettes, or glass capillaries pulled to nanoscale tip dimensions, and micron-sized electrospray ionization emitters. Direct visualization of charged fluorophores during the electrospray process is used to evaluate impacts of emitter size, ionic strength, analyte size, and pressure-driven flow on heterogeneous ion transport during electrospray. Mass spectrometric measurements of positively- and negatively-charged proteins were taken for micron-sized and nanopipette emitters under low ionic strength conditions to further illustrate a discrepancy in solution-driven transport of charged analytes. A fundamental understanding of analyte electromigration during electrospray, which is not always considered, is expected to provide control over selective analyte depletion and enrichment, and can be harnessed for sample cleanup. Graphical abstract Fluorescence micrographs of ion migration in nanoscale pipettes while solution is electrosprayed.
Collapse
|
14
|
Yang JM, Pan ZQ, Qin FF, Chen M, Wang K, Xia XH. Anin situSERS study of ionic transport and the Joule heating effect in plasmonic nanopores. Chem Commun (Camb) 2018; 54:13236-13239. [DOI: 10.1039/c8cc07153e] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The ionic transport behaviour as well as temperature change caused by the Joule heating effect in plasmonic nanopores is studied byin situSERS measurement.
Collapse
Affiliation(s)
- Jin-Mei Yang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University
- Nanjing 210023
- China
| | - Zhong-Qin Pan
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University
- Nanjing 210023
- China
| | - Fei-Fei Qin
- Department of Physics, Southeast University
- Nanjing 210096
- China
| | - Ming Chen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University
- Nanjing 210023
- China
| | - Kang Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University
- Nanjing 210023
- China
| | - Xing-Hua Xia
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University
- Nanjing 210023
- China
| |
Collapse
|
15
|
Oskooei A, Kaigala GV. Deep-Reaching Hydrodynamic Flow Confinement: Micrometer-Scale Liquid Localization for Open Substrates With Topographical Variations. IEEE Trans Biomed Eng 2017; 64:1261-1269. [PMID: 28541189 DOI: 10.1109/tbme.2016.2597297] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We present a method for nonintrusive localization and reagent delivery on immersed biological samples with topographical variation on the order of hundreds of micrometers. Our technique, which we refer to as the deep-reaching hydrodynamic flow confinement (DR-HFC), is simple and passive: it relies on a deep-reaching hydrodynamic confinement delivered through a simple microfluidic probe design to perform localized microscale alterations on substrates as deep as 600 μm. Designed to scan centimeter-scale areas of biological substrates, our method passively prevents sample intrusion by maintaining a large gap between the probe and the substrate. The gap prevents collision of the probe and the substrate and reduces the shear stress experienced by the sample. We present two probe designs: linear and annular DR-HFC. Both designs comprise a reagent-injection aperture and aspiration apertures that serve to confine the reagent. We identify the design parameters affecting reagent localization and depth by DR-HFC and study their individual influence on the operation of DR-HFC numerically. Using DR-HFC, we demonstrate localized binding of antihuman immunoglobulin G (IgG) onto an activated substrate at various depths from 50 to 600 μm. DR-HFC provides a readily implementable approach for noninvasive processing of biological samples applicable to the next generation of diagnostic and bioanalytical devices.
Collapse
|
16
|
Page A, Perry D, Unwin PR. Multifunctional scanning ion conductance microscopy. Proc Math Phys Eng Sci 2017; 473:20160889. [PMID: 28484332 PMCID: PMC5415692 DOI: 10.1098/rspa.2016.0889] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 03/13/2017] [Indexed: 12/21/2022] Open
Abstract
Scanning ion conductance microscopy (SICM) is a nanopipette-based technique that has traditionally been used to image topography or to deliver species to an interface, particularly in a biological setting. This article highlights the recent blossoming of SICM into a technique with a much greater diversity of applications and capability that can be used either standalone, with advanced control (potential-time) functions, or in tandem with other methods. SICM can be used to elucidate functional information about interfaces, such as surface charge density or electrochemical activity (ion fluxes). Using a multi-barrel probe format, SICM-related techniques can be employed to deposit nanoscale three-dimensional structures and further functionality is realized when SICM is combined with scanning electrochemical microscopy (SECM), with simultaneous measurements from a single probe opening up considerable prospects for multifunctional imaging. SICM studies are greatly enhanced by finite-element method modelling for quantitative treatment of issues such as resolution, surface charge and (tip) geometry effects. SICM is particularly applicable to the study of living systems, notably single cells, although applications extend to materials characterization and to new methods of printing and nanofabrication. A more thorough understanding of the electrochemical principles and properties of SICM provides a foundation for significant applications of SICM in electrochemistry and interfacial science.
Collapse
Affiliation(s)
- Ashley Page
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
- MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, UK
| | - David Perry
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
- MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, UK
| | - Patrick R. Unwin
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
| |
Collapse
|
17
|
Yao H, Zeng J, Zhai P, Li Z, Cheng Y, Liu J, Mo D, Duan J, Wang L, Sun Y, Liu J. Large Rectification Effect of Single Graphene Nanopore Supported by PET Membrane. ACS APPLIED MATERIALS & INTERFACES 2017; 9:11000-11008. [PMID: 28262018 DOI: 10.1021/acsami.6b16736] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Graphene is an ideal candidate for the development of solid state nanopores due to its thickness at the atomic scale and its high chemical and mechanical stabilities. A facile method was adopted to prepare single graphene nanopore supported by PET membrane (G/PET nanopore) within the three steps assisted by the swift heavy ion irradiation and asymmetric etching technology. The inversion of the ion rectification effect was confirmed in G/PET nanopore while comparing with bare PET nanopore in KCl electrolyte solution. By modifying the wall charge state of PET conical nanopore with hydrochloric acid from negative to positive, the ion rectification effect of G/PET nanopore was found to be greatly enhanced and the large rectification ratio up to 190 was obtained during this work. Moreover, the high ionic flux and high ion separation efficiency was also observed in the G/PET nanopore system. By comparing the "on" and "off" state conductance of G/PET nanopore while immersed in the solution with pH value lower than the isoelectric point of the etched PET (IEP, pH = 3.8), the voltage dependence of the off conductance was established and it was confirmed that the large rectification effect was strongly dependent on the particularly low off conductance at higher applied voltage.
Collapse
Affiliation(s)
- Huijun Yao
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
| | - Jian Zeng
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
| | - Pengfei Zhai
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
| | - Zongzhen Li
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
- University of Chinese Academy of Sciences , Beijing 100049, China
| | - Yaxiong Cheng
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
- University of Chinese Academy of Sciences , Beijing 100049, China
| | - Jiande Liu
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
| | - Dan Mo
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
| | - Jinglai Duan
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
| | - Lanxi Wang
- Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics , Feiyan Street 100, Lanzhou 730000, China
| | - Youmei Sun
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
| | - Jie Liu
- Institute of Modern Physics, Chinese Academy of Sciences , Lanzhou 730000, China
| |
Collapse
|
18
|
Wang Y, Wang D, Mirkin MV. Resistive-pulse and rectification sensing with glass and carbon nanopipettes. Proc Math Phys Eng Sci 2017; 473:20160931. [PMID: 28413354 DOI: 10.1098/rspa.2016.0931] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Accepted: 02/08/2017] [Indexed: 11/12/2022] Open
Abstract
Along with more prevalent solid-state nanopores, glass or quartz nanopipettes have found applications in resistive-pulse and rectification sensing. Their advantages include the ease of fabrication, small physical size and needle-like geometry, rendering them useful for local measurements in small spaces and delivery of nanoparticles/biomolecules. Carbon nanopipettes fabricated by depositing a thin carbon layer on the inner wall of a quartz pipette provide additional means for detecting electroactive species and fine-tuning the current rectification properties. In this paper, we discuss the fundamentals of resistive-pulse sensing with nanopipettes and our recent studies of current rectification in carbon pipettes.
Collapse
Affiliation(s)
- Yixian Wang
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA 90032, USA
| | - Dengchao Wang
- Department of Chemistry and Biochemistry, Queens College, City University of New York, Flushing, NY 11367, USA
| | - Michael V Mirkin
- Department of Chemistry and Biochemistry, Queens College, City University of New York, Flushing, NY 11367, USA
| |
Collapse
|
19
|
Affiliation(s)
- Wenqing Shi
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Alicia K. Friedman
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Lane A. Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|
20
|
Affiliation(s)
- David Perry
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Dmitry Momotenko
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Robert A. Lazenby
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Minkyung Kang
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry CV4 7AL, United Kingdom
| |
Collapse
|
21
|
Cai H, Wang Y, Yu Y, Mirkin MV, Bhakta S, Bishop GW, Joshi AA, Rusling JF. Resistive-Pulse Measurements with Nanopipettes: Detection of Vascular Endothelial Growth Factor C (VEGF-C) Using Antibody-Decorated Nanoparticles. Anal Chem 2015; 87:6403-10. [PMID: 26040997 PMCID: PMC4598329 DOI: 10.1021/acs.analchem.5b01468] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Quartz nanopipettes have recently been employed for resistive-pulse sensing of Au nanoparticles (AuNP) and nanoparticles with bound antibodies. The analytical signal in such experiments is the change in ionic current caused by the nanoparticle translocation through the pipette orifice. This paper describes resistive-pulse detection of cancer biomarker (Vascular Endothelial Growth Factor-C, VEGF-C) through the use of antibody-modified AuNPs and nanopipettes. The main challenge was to differentiate between AuNPs with attached antibodies for VEGF-C and antigen-conjugated particles. The zeta-potentials of these types of particles are not very different, and, therefore, carefully chosen pipettes with well-characterized geometry were necessary for selective detection of VEGF-C.
Collapse
Affiliation(s)
- Huijing Cai
- Department of Chemistry and Biochemistry, Queens College—CUNY, Flushing, New York 11367, United States
| | - Yixian Wang
- Department of Chemistry and Biochemistry, Queens College—CUNY, Flushing, New York 11367, United States
| | - Yun Yu
- Department of Chemistry and Biochemistry, Queens College—CUNY, Flushing, New York 11367, United States
| | - Michael V. Mirkin
- Department of Chemistry and Biochemistry, Queens College—CUNY, Flushing, New York 11367, United States
| | - Snehasis Bhakta
- Department of Chemistry, U-60, University of Connecticut, 55 N. Eagleville Rd., Storrs, Connecticut 06269-3060, United States
| | - Gregory W. Bishop
- Department of Chemistry, U-60, University of Connecticut, 55 N. Eagleville Rd., Storrs, Connecticut 06269-3060, United States
| | - Amit A. Joshi
- Department of Chemistry, U-60, University of Connecticut, 55 N. Eagleville Rd., Storrs, Connecticut 06269-3060, United States
| | - James F. Rusling
- Department of Chemistry, U-60, University of Connecticut, 55 N. Eagleville Rd., Storrs, Connecticut 06269-3060, United States
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut, United States
- School of Chemistry, National University of Ireland at Galway, Galway, Ireland
| |
Collapse
|
22
|
Saha-Shah A, Weber AE, Karty JA, Ray SJ, Hieftje GM, Baker LA. Nanopipettes: probes for local sample analysis. Chem Sci 2015; 6:3334-3341. [PMID: 28706697 PMCID: PMC5490420 DOI: 10.1039/c5sc00668f] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Accepted: 04/02/2015] [Indexed: 01/02/2023] Open
Abstract
Nanopipettes are demonstrated as probes for local mass spectrometric analysis with potential for small-scale extraction of analytes from single cells, tissue and organisms.
Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.
Collapse
Affiliation(s)
- Anumita Saha-Shah
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , IN 47405 , USA .
| | - Anna E Weber
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , IN 47405 , USA .
| | - Jonathan A Karty
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , IN 47405 , USA .
| | - Steven J Ray
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , IN 47405 , USA .
| | - Gary M Hieftje
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , IN 47405 , USA .
| | - Lane A Baker
- Department of Chemistry , Indiana University , 800 E. Kirkwood Avenue , Bloomington , IN 47405 , USA .
| |
Collapse
|
23
|
Abstract
Accelerated aging experiments of Nafion® 212 (N212) membranes were carried out. Characterization of degraded N212 membrane samples was performed by microscopy, spectroscopy and electrochemical methods.
Collapse
Affiliation(s)
- Wenqing Shi
- Department of Chemistry
- Indiana University
- Bloomington
- USA
| | - Lane A. Baker
- Department of Chemistry
- Indiana University
- Bloomington
- USA
| |
Collapse
|
24
|
Haywood DG, Saha-Shah A, Baker LA, Jacobson SC. Fundamental studies of nanofluidics: nanopores, nanochannels, and nanopipets. Anal Chem 2014; 87:172-87. [PMID: 25405581 PMCID: PMC4287834 DOI: 10.1021/ac504180h] [Citation(s) in RCA: 157] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Daniel G Haywood
- Department of Chemistry, Indiana University , Bloomington, Indiana 47405-7102, United States
| | | | | | | |
Collapse
|