1
|
Abstract
Metabolomics aims to profile the extensive array of metabolites that exists in different types of matrices using modern analytical techniques. These techniques help to separate, identify, and quantify the plethora of chemical compounds at various analytical platforms. Hence, ion mobility spectrometry (IMS) has emerged as an advanced analytical approach, exclusively owing to the 3D separation of metabolites and their isomers. Furthermore, separated metabolites are identified based on their mass fragmentation pattern and CCS (collision cross-section) values. The IMS provides an advanced alternative dimension to separate the isomeric metabolites with enhanced throughput with lesser chemical noise. Thus, the present review highlights the types, factors affecting the resolution, and applications of IMMS (Ion mobility mass spectrometry) for isomeric separations, and ionic contaminants in the plant samples. Furthermore, an overview of IMS-based applications for the identification of plant metabolites (volatile and non-volatile) over the last few decades has been discussed, followed by future assumptions for creating IM-based databases. Such approaches could be significant to accelerate and improve our knowledge of the vast chemical diversity found in plants.
Collapse
Affiliation(s)
- Robin Joshi
- Biotechnology Division, CSIR-Institute of Himalayan Bioresource Technology, Palampur, Himachal Pradesh, India
- Academy of Scientific and Innovative Research, (AcSIR), Ghaziabad, India
| | - Shruti Sharma
- Academy of Scientific and Innovative Research, (AcSIR), Ghaziabad, India
- Chemical Technology Division, CSIR-Institute of Himalayan Bioresource Technology, Palampur, Himachal Pradesh, India
| | - Dinesh Kumar
- Academy of Scientific and Innovative Research, (AcSIR), Ghaziabad, India
- Chemical Technology Division, CSIR-Institute of Himalayan Bioresource Technology, Palampur, Himachal Pradesh, India
| |
Collapse
|
2
|
Pathak P, Shvartsburg AA. Assessing the Dipole Moments and Directional Cross Sections of Proteins and Complexes by Differential Ion Mobility Spectrometry. Anal Chem 2022; 94:7041-7049. [PMID: 35500292 DOI: 10.1021/acs.analchem.2c00343] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Ion mobility spectrometry (IMS) has become a mainstream approach to fractionate complex mixtures, separate isomers, and assign the molecular geometries. All modalities were grouped into linear IMS (based on the absolute ion mobility, K) and field asymmetric waveform IMS (FAIMS) relying on the evolution of K at a high normalized electric field (E/N) that induces strong ion heating. In the recently demonstrated low-field differential (LOD) IMS, the field is too weak for significant heating but locks the macromolecular dipoles to produce novel separations controlled by the relevant directional collision cross sections (CCSs). Here, we show LODIMS for mass-selected species, exploring the dipole alignment across charge states for the monomers and dimers of an exemplary protein, the alcohol dehydrogenase. Distinct conformational families for aligned species are revealed with directional CCS estimated from the field-dependent trend lines. We set up a model to extract the fractions of pendular conformers as a function of field intensity and translate them into dipole moment distributions. These developments make a critical step toward establishing LODIMS as a new tool for top-down proteomics and integrative structural biology.
Collapse
Affiliation(s)
- Pratima Pathak
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| | - Alexandre A Shvartsburg
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| |
Collapse
|
3
|
Ruskic D, Klont F, Hopfgartner G. Clustering and Nonclustering Modifier Mixtures in Differential Mobility Spectrometry for Multidimensional Liquid Chromatography Ion Mobility-Mass Spectrometry Analysis. Anal Chem 2021; 93:6638-6645. [PMID: 33891812 DOI: 10.1021/acs.analchem.0c04889] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Modifiers provide fast and reliable tuning of separation in differential mobility spectrometry (DMS). DMS selectivity for separating isomeric molecules depends on the clustering modifier concentration, which is typically 1.5-3 mol % ratio of isopropanol or ethanol in nitrogen. Low concentrations (0.1%) of isopropanol were found to improve resolution and sensitivity but at the cost of practicality and robustness. Replacing the single-channel DMS pump with a binary high-performance liquid chromatography (HPLC) pump enabled the generation of modifier mixtures at a constant flow rate using an isocratic or gradient mode, and the analytical benefits of the system were investigated considering cyclohexane, n-hexane, or n-octane as nonclustering modifiers and isopropanol or ethanol as clustering modifiers. It was found that clustering and nonclustering modifier mixtures enable optimization of selectivity, resolution, and sensitivity for different positional isomers and diastereoisomers. Data further suggested different ion separation mechanisms depending on the modifier ratios. For 85 analytes, the absolute difference in compensation voltages (CoVs) between pure nitrogen and cyclohexane at 1.5 mol % ratio was below 4 V, demonstrating its potential as a nonclustering modifier. Cyclohexane's nonclustering behavior was further supported by molecular modeling using density functional theory (DFT) and calculated cluster binding energies, showing positive ΔG values. The ability to control analyte CoVs by adjusting modifier concentrations in isocratic and gradient modes is beneficial for optimizing multidimensional LCxDMS-MS. It is fast and effective for manipulating the DMS scanning window size to realize shorter mass spectrometry (MS) acquisition cycle times while maintaining a sufficient number of CoV steps and without compromising DMS separation performance.
Collapse
Affiliation(s)
- David Ruskic
- Life Sciences Mass Spectrometry, Department of Inorganic and Analytical Chemistry, University of Geneva, 24 Quai Ernest Ansermet, CH-1211 Geneva 4, Switzerland
| | - Frank Klont
- Life Sciences Mass Spectrometry, Department of Inorganic and Analytical Chemistry, University of Geneva, 24 Quai Ernest Ansermet, CH-1211 Geneva 4, Switzerland
| | - Gérard Hopfgartner
- Life Sciences Mass Spectrometry, Department of Inorganic and Analytical Chemistry, University of Geneva, 24 Quai Ernest Ansermet, CH-1211 Geneva 4, Switzerland
| |
Collapse
|
4
|
Eldrid C, Thalassinos K. Developments in tandem ion mobility mass spectrometry. Biochem Soc Trans 2020; 48:2457-2466. [PMID: 33336686 PMCID: PMC7752082 DOI: 10.1042/bst20190788] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 10/14/2020] [Accepted: 11/17/2020] [Indexed: 01/09/2023]
Abstract
Ion Mobility (IM) coupled to mass spectrometry (MS) is a useful tool for separating species of interest out of small quantities of heterogenous mixtures via a combination of m/z and molecular shape. While tandem MS instruments are common, instruments which employ tandem IM are less so with the first commercial IM-MS instrument capable of multiple IM selection rounds being released in 2019. Here we explore the history of tandem IM instruments, recent developments, the applications to biological systems and expected future directions.
Collapse
Affiliation(s)
- Charles Eldrid
- Institute of Structural and Molecular Biology, UCL, Gower St, London WC1E 6BT, U.K
| | - Konstantinos Thalassinos
- Institute of Structural and Molecular Biology, UCL, Gower St, London WC1E 6BT, U.K
- Institute of Structural and Molecular Biology, Birkbeck University, Malet Place, London WC1E 7HX, U.K
| |
Collapse
|
5
|
Berthias F, Wang Y, Alhajji E, Rieul B, Moussa F, Benoist JF, Maître P. Identification and quantification of amino acids and related compounds based on Differential Mobility Spectrometry. Analyst 2020; 145:4889-4900. [DOI: 10.1039/d0an00377h] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
A new metabolite descriptor allowing fast quantification for the diagnosis of metabolic diseases.
Collapse
Affiliation(s)
- Francis Berthias
- Université Paris-Saclay
- CNRS
- Institut de Chimie Physique
- Orsay
- France
| | - Yali Wang
- Université Paris-Saclay
- CNRS
- Institut de Chimie Physique
- Orsay
- France
| | - Eskander Alhajji
- Université Paris-Saclay
- CNRS
- Institut de Chimie Physique
- Orsay
- France
| | - Bernard Rieul
- Université Paris-Saclay
- CNRS
- Institut de Chimie Physique
- Orsay
- France
| | - Fathi Moussa
- Université Paris-Saclay
- CNRS
- Institut de Chimie Physique
- Orsay
- France
| | - Jean-François Benoist
- Université Paris-Saclay
- Lipides
- Systèmes Analytiques et Biologiques
- Châtenay-Malabry
- France
| | - Philippe Maître
- Université Paris-Saclay
- CNRS
- Institut de Chimie Physique
- Orsay
- France
| |
Collapse
|
6
|
Amo-González M, Pérez S, Delgado R, Arranz G, Carnicero I. Tandem Ion Mobility Spectrometry for the Detection of Traces of Explosives in Cargo at Concentrations of Parts Per Quadrillion. Anal Chem 2019; 91:14009-14018. [DOI: 10.1021/acs.analchem.9b03589] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
| | - Sergio Pérez
- SEADM, Parque Tecnológico de Boecillo 205, Valladolid, Spain
| | - Rafael Delgado
- SEADM, Parque Tecnológico de Boecillo 205, Valladolid, Spain
| | - Gonzalo Arranz
- SEADM, Parque Tecnológico de Boecillo 205, Valladolid, Spain
| | - Irene Carnicero
- SEADM, Parque Tecnológico de Boecillo 205, Valladolid, Spain
| |
Collapse
|
7
|
Bohnhorst A, Kirk AT, Yin Y, Zimmermann S. Ion Fragmentation and Filtering by Alpha Function in Ion Mobility Spectrometry for Improved Compound Differentiation. Anal Chem 2019; 91:8941-8947. [DOI: 10.1021/acs.analchem.9b00810] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Alexander Bohnhorst
- Leibniz Universität Hannover, Institute of Electrical Engineering and Measurement Technology Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Ansgar T. Kirk
- Leibniz Universität Hannover, Institute of Electrical Engineering and Measurement Technology Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Yu Yin
- Leibniz Universität Hannover, Institute of Electrical Engineering and Measurement Technology Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Leibniz Universität Hannover, Institute of Electrical Engineering and Measurement Technology Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| |
Collapse
|
8
|
Anishchenko IM, McCartney MM, Fung AG, Peirano DJ, Schirle MJ, Kenyon NJ, Davis CE. Modular and reconfigurable gas chromatography / differential mobility spectrometry (GC/DMS) package for detection of volatile organic compounds (VOCs). ACTA ACUST UNITED AC 2018; 21:125-136. [PMID: 31086501 DOI: 10.1007/s12127-018-0240-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Due to the versatility of present day microcontroller boards and open source development environments, new analytical chemistry devices can now be built outside of large industry and instead within smaller individual groups. While there are a wide range of commercial devices available for detecting and identifying volatile organic compounds (VOCs), most of these devices use their own proprietary software and complex custom electronics, making modifications or reconfiguration of the systems challenging. The development of microprocessors for general use, such as the Arduino prototyping platform, now enables custom chemical analysis instrumentation. We have created an example system using commercially available parts, centered around on differential mobility spectrometer (DMS) device. The Modular Reconfigurable Gas Chromatography - Differential Mobility Spectrometry package (MR-GC-DMS) has swappable components allowing it to be quickly reconfigured for specific application purposes as well as broad, generic use. The MR-GC-DMS has a custom user-friendly graphical user interface (GUI) and precisely tuned proportional-integral-derivative controller (PID) feedback control system managing individual temperature-sensitive components. Accurate temperature control programmed into the microcontroller greatly increases repeatability and system performance. Together, this open-source platform enables researchers to quickly combine DMS devices in customized configurations for new chemical sensing applications.
Collapse
Affiliation(s)
- Ilya M Anishchenko
- Department of Mechanical and Aerospace Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA
| | - Mitchell M McCartney
- Department of Mechanical and Aerospace Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA
| | - Alexander G Fung
- Department of Mechanical and Aerospace Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA
| | - Daniel J Peirano
- Department of Mechanical and Aerospace Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA
| | - Michael J Schirle
- Department of Mechanical and Aerospace Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA
| | - Nicholas J Kenyon
- Department of Internal Medicine, University of California, 4150 V Street, Suite 3400, Davis, Sacramento, CA 95817, USA.,Center for Comparative Respiratory Biology and Medicine, University of California, Davis, CA 95616, USA
| | - Cristina E Davis
- Department of Mechanical and Aerospace Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA
| |
Collapse
|
9
|
Amo-González M, Carnicero I, Pérez S, Delgado R, Eiceman GA, Fernández de la Mora G, Fernández de la Mora J. Ion Mobility Spectrometer-Fragmenter-Ion Mobility Spectrometer Analogue of a Triple Quadrupole for High-Resolution Ion Analysis at Atmospheric Pressure. Anal Chem 2018; 90:6885-6892. [DOI: 10.1021/acs.analchem.8b01086] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
| | - Irene Carnicero
- SEADM, Parque Tecnológico de Boecillo 205, Valladolid, Spain 47151
| | - Sergio Pérez
- SEADM, Parque Tecnológico de Boecillo 205, Valladolid, Spain 47151
| | - Rafael Delgado
- SEADM, Parque Tecnológico de Boecillo 205, Valladolid, Spain 47151
| | - Gary A. Eiceman
- Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces, New Mexico 88003, United States
- Chemistry Department, Loughborough University, Loughborough, U.K. LE11 3TU
| | | | - Juan Fernández de la Mora
- Mechanical Engineering Department, Yale University, New Haven, Connecticut 06520-8286, United States
| |
Collapse
|
10
|
Microscale differential ion mobility spectrometry for field deployable chemical analysis. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.10.011] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
11
|
Shvartsburg AA, Haris A, Andrzejewski R, Entwistle A, Giles R. Differential Ion Mobility Separations in the Low-Pressure Regime. Anal Chem 2017; 90:936-943. [DOI: 10.1021/acs.analchem.7b03925] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Alexandre A. Shvartsburg
- Department of Chemistry, Wichita State University, 1845 Fairmount, Wichita, Kansas 67260, United States
| | - Anisha Haris
- Shimadzu Research Laboratory, Wharfside, Trafford Wharf Road, Manchester M17 1GP, United Kingdom
| | - Roch Andrzejewski
- Shimadzu Research Laboratory, Wharfside, Trafford Wharf Road, Manchester M17 1GP, United Kingdom
| | - Andrew Entwistle
- Shimadzu Research Laboratory, Wharfside, Trafford Wharf Road, Manchester M17 1GP, United Kingdom
| | - Roger Giles
- Shimadzu Research Laboratory, Wharfside, Trafford Wharf Road, Manchester M17 1GP, United Kingdom
| |
Collapse
|
12
|
Santiago BG, Campbell MT, Glish GL. Variables Affecting the Internal Energy of Peptide Ions During Separation by Differential Ion Mobility Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2160-2169. [PMID: 28653242 DOI: 10.1007/s13361-017-1726-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 05/07/2017] [Accepted: 05/22/2017] [Indexed: 06/07/2023]
Abstract
Differential ion mobility spectrometry (DIMS) devices separate ions on the basis of differences in ion mobility in low and high electric fields, and can be used as a stand-alone analytical method or as a separation step before further analysis. As with other ion mobility separation techniques, the ability of DIMS separations to retain the structural characteristics of analytes has been of concern. For DIMS separations, this potential loss of ion structure originates from the fact that the separations occur at atmospheric pressure and the ions, during their transit through the device, undergo repeated collisions with the DIMS carrier gas while being accelerated by the electric field. These collisions have the ability to increase the internal energy distribution of the ions, which can cause isomerization or fragmentation. The increase in internal energy of the ions is based on a number of variables, including the dispersion field and characteristics of the carrier gas such as temperature and composition. The effects of these parameters on the intra-DIMS fragmentation of multiply charged ions of the peptides bradykinin (RPPGFSPFR) and GLISH are discussed herein. Furthermore, similarities and differences in the internal energy deposition that occur during collisional activation in tandem mass spectrometry experiments are discussed, as the fragmentation pathways accessed by both are similar. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Brandon G Santiago
- Department of Chemistry, Caudill Laboratories, The University of North Carolina at Chapel Hill, Campus Box 3290, Chapel Hill, NC, 27599-3290, USA
| | - Matthew T Campbell
- Department of Chemistry, Caudill Laboratories, The University of North Carolina at Chapel Hill, Campus Box 3290, Chapel Hill, NC, 27599-3290, USA
| | - Gary L Glish
- Department of Chemistry, Caudill Laboratories, The University of North Carolina at Chapel Hill, Campus Box 3290, Chapel Hill, NC, 27599-3290, USA.
| |
Collapse
|
13
|
Ion mobility spectrometry: Current status and application for chemical warfare agents detection. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.06.002] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
14
|
Arthur KL, Eiceman GA, Reynolds JC, Creaser CS. Analysis of Supramolecular Complexes of 3-Methylxanthine with Field Asymmetric Waveform Ion Mobility Spectrometry Combined with Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:800-809. [PMID: 26914231 DOI: 10.1007/s13361-016-1351-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 01/22/2016] [Accepted: 01/23/2016] [Indexed: 06/05/2023]
Abstract
Miniaturised field asymmetric waveform ion mobility spectrometry (FAIMS), combined with mass spectrometry (MS), has been applied to the study of self-assembling, noncovalent supramolecular complexes of 3-methylxanthine (3-MX) in the gas phase. 3-MX forms stable tetrameric complexes around an alkali metal (Na(+), K(+)) or ammonium cation, to generate a diverse array of complexes with single and multiple charge states. Complexes of (3-MX)n observed include: singly charged complexes where n = 1-8 and 12 and doubly charged complexes where n = 12-24. The most intense ions are those associated with multiples of tetrameric units, where n = 4, 8, 12, 16, 20, 24. The effect of dispersion field on the ion intensities of the self-assembled complexes indicates some fragmentation of higher order complexes within the FAIMS electrodes (in-FAIMS dissociation), as well as in-source collision induced dissociation within the mass spectrometer. FAIMS-MS enables charge state separation of supramolecular complexes of 3-MX and is shown to be capable of separating species with overlapping mass-to-charge ratios. FAIMS selected transmission also results in an improvement in signal-to-noise ratio for low intensity complexes and enables the visualization of species undetectable without FAIMS.
Collapse
Affiliation(s)
- Kayleigh L Arthur
- Center for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, LE11 3TU, UK
| | - Gary A Eiceman
- Center for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, LE11 3TU, UK
- Department of Chemistry and Biochemistry, New Mexico State University, MSC 3C, P.O. Box 3001, Las Cruces, NM, 88003-8001, USA
| | - James C Reynolds
- Center for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, LE11 3TU, UK.
| | - Colin S Creaser
- Center for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, LE11 3TU, UK.
| |
Collapse
|