1
|
Lai X, Zhang G, Deng S, Zhang G, Xiao X, He W, Su L, Liu C, Lai W. Triple strategy-enhanced immunochromatographic assay based on APCB and AIEFM for the ultrasensitive detection of AFM1. JOURNAL OF HAZARDOUS MATERIALS 2023; 460:132438. [PMID: 37666170 DOI: 10.1016/j.jhazmat.2023.132438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 08/08/2023] [Accepted: 08/28/2023] [Indexed: 09/06/2023]
Abstract
Aflatoxin M1 (AFM1) is highly toxic, widely distributed, and difficult to monitor, posing a serious threat to human health. Therefore, a highly sensitive, rapid, convenient, and low-cost detection method must be urgently established. In this study, a triple strategy-enhanced immunochromatographic assay (ICA) was developed to satisfy these detection requirements. First, a turn-on signal output mode of the fluorescence quenching ICA substituted the turn-off mode of the traditional ICA for sensitive response to trace AFM1, with the limit of detection (LOD) reduced by approximately 4.9-fold. Then, a novel Au and polydopamine (PDA) cogrowth chrysanthemum-like blackbody was prepared as the quenching probe to reduce the background signal. This probe combined the excellent properties of Au nanoparticles with PDA. Thus, its fluorescence quenching constant was higher than that of single Au and PDA nanoparticles by 25.8- and 4.9-fold, respectively. Furthermore, an aggregation-induced emission fluorescence microsphere with a 5.7-fold higher relative quantum yield than a commercial fluorescence microsphere was selected as the signal output carrier to improve the signal-to-noise ratio. The integration of the above triple strategies established a 53.4-fold sensitivity-enhanced fluorescence quenching ICA (LOD = 0.9 pg/mL) for detecting AFM1 in milk, providing a strong technical guarantee for the safety monitoring of milk products.
Collapse
Affiliation(s)
- Xiaocui Lai
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China
| | - Ganggang Zhang
- Institute of Microbiology, Jiangxi Academy of Sciences, Nanchang 330096, China
| | - Shengliang Deng
- Institute of Microbiology, Jiangxi Academy of Sciences, Nanchang 330096, China.
| | - Gan Zhang
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China
| | - Xiaoyue Xiao
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China
| | - Weihua He
- Institute of Microbiology, Jiangxi Academy of Sciences, Nanchang 330096, China
| | - Liu Su
- Institute of Microbiology, Jiangxi Academy of Sciences, Nanchang 330096, China
| | - Cong Liu
- Institute of Microbiology, Jiangxi Academy of Sciences, Nanchang 330096, China
| | - Weihua Lai
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China.
| |
Collapse
|
2
|
Pan Y, Wang Z, Duan C, Dou L, Wen K, Wang Z, Yu X, Shen J. Comparison of two fluorescence quantitative immunochromatographic assays for the detection of amantadine in chicken muscle. Food Chem 2022; 377:131931. [PMID: 34998149 DOI: 10.1016/j.foodchem.2021.131931] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 12/16/2021] [Accepted: 12/20/2021] [Indexed: 11/18/2022]
Abstract
The two sensitive fluorescence quantitative immunochromatographic assays (FQICAs), background fluorescence quenching immunochromatographic assay (bFQICA) and time-resolved fluorescent immunochromatographic assay (TRFICA), play an important role increasingly in rapid detection technology for food safety. Amantadine (AMD), used extensively in virus infections in livestock and poultry, has been prohibited due to hazard concerns over public human health. Therefore, AMD was used as a model molecule in the FQICAs establishment and comparison based on the same bioreagents. The outstanding performance in technical parameters of the two FQICAs indicated that they could provide rapid, precise, reliable technical support for large-scale on-site screening for AMD detection. What's more, the systematic and comprehensive comparison of the two FQICAs would give useful suggestions for scientists and users in monitoring the harmful compounds.
Collapse
Affiliation(s)
- Yantong Pan
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing 100193, People's Republic of China
| | - Zhaopeng Wang
- College of Food Science and Pharmaceutical Engineering, Zaozhuang University, Zaozhuang 277160, Shandong, People's Republic of China
| | - Changfei Duan
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing 100193, People's Republic of China
| | - Leina Dou
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing 100193, People's Republic of China
| | - Kai Wen
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing 100193, People's Republic of China
| | - Zhanhui Wang
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing 100193, People's Republic of China
| | - Xuezhi Yu
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing 100193, People's Republic of China.
| | - Jianzhong Shen
- College of Veterinary Medicine, China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing 100193, People's Republic of China.
| |
Collapse
|
3
|
Ensuring food safety using fluorescent nanoparticles-based immunochromatographic test strips. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.10.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
4
|
Xiao W, Liang J, Zhang Y, Zhang Y, Teng P, Cao D, Zou S, Xu T, Zhao J, Tang Y. CD8 cell counting in whole blood by a paper-based time-resolved fluorescence lateral flow immunoassay. Anal Chim Acta 2021; 1179:338820. [PMID: 34535251 DOI: 10.1016/j.aca.2021.338820] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 06/28/2021] [Accepted: 06/30/2021] [Indexed: 12/11/2022]
Abstract
The number of CD8+ T lymphocytes (CD8 cells) in peripheral blood can directly reflect the immune status of the body and is widely used for auxiliary diagnosis and prognostic evaluation of diseases. There is an urgent need to develop a simple CD8 cell-counting platform to meet clinical needs. Our group designed a paper-based cell-counting method based on a blocking competition strategy. In addition, we developed a time-resolved fluorescence-blocking competitive lateral flow immunoassay (TRF-BCLFIA) for point-of-care CD8 cell counting that functions by measuring europium nanoparticle (EuNP)-labeled CD8 antibody probes that are not captured by CD8 cells, and we indirectly calculated the concentration of CD8 cells in samples. Within 30 min, four operation steps can provide an accurate CD8 cell count for a 75-μL whole-blood sample, and this approach can be implemented on a handheld device. The TRF-BCLFIA reliably quantified CD8 cells in whole-blood samples, in which the assay exhibited a linear correlation (R2 = 0.989) readout for CD8 cell concentrations ranging from 137 to 821 cells/μL. To validate this approach, our newly developed CD8 cell-counting tool was used to assess 33 tumor patient blood samples. The results showed a high consistency with a flow cytometry-based absolute count. This analysis approach is a promising alternative for the costly standard flow cytometry-based tools for CD8 cell counting in tumor patients in community clinics, small hospitals, and low medical resource regions. This technology would deliver simple diagnostics to patients anywhere in the world, regardless of geography or socioeconomic status.
Collapse
Affiliation(s)
- Wei Xiao
- Department of Laboratory Medicine, Guangdong Second Provincial General Hospital, Guangzhou, 510317, PR China
| | - Jiajie Liang
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Ying Zhang
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Yan Zhang
- Department of Oncology, The First Affiliated Hospital, Jinan University, Guangzhou, Guangdong, 510630, PR China
| | - Peijun Teng
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Dongni Cao
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Siyi Zou
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Tao Xu
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China
| | - Jianfu Zhao
- Department of Oncology, The First Affiliated Hospital, Jinan University, Guangzhou, Guangdong, 510630, PR China.
| | - Yong Tang
- Department of Bioengineering, Guangdong Province Engineering Research Center of Antibody Drug and Immunoassay, Jinan University, Guangzhou, 510632, PR China.
| |
Collapse
|
5
|
Zhu J, Dou L, Mi J, Bai Y, Liu M, Shen J, Yu W, Zhang S, Yu X, Wang Z. Production of highly sensitive monoclonal antibody and development of lateral flow assays for phallotoxin detection in urine. Anal Bioanal Chem 2021; 413:4979-4987. [PMID: 34240228 DOI: 10.1007/s00216-021-03457-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/18/2021] [Accepted: 06/07/2021] [Indexed: 10/20/2022]
Abstract
Phallotoxins, toxic cyclopeptides found in wild poisonous mushrooms, are predominant causes of fatal food poisoning. For the early and rapid diagnosis mushroom toxin poisoning, a highly sensitive and robust monoclonal antibody (mAb) against phallotoxins was produced for the first time. The half-maximum inhibition concentration (IC50) values of the mAb-based indirect competitive ELISAs for phallacidin (PCD) and phalloidin (PHD) detection were 0.31 ng mL-1 and 0.35 ng mL-1, respectively. In response to the demand for rapid screening of the type of poisoning and accurate determination of the severity of poisoning, colloidal gold nanoparticle (GNP) and time-resolved fluorescent nanosphere (TRFN) based lateral flow assays (LFA) were developed. The GNP-LFA has a visual cut-off value of 3.0 ng mL-1 for phallotoxins in human urine sample. The TRFN-LFA provides a quantitative readout signal with detection limit of 0.1 ng mL-1 in human urine sample. In this study, urine samples without pretreatment were used directly for the LFA strip tests, and both two LFAs were able to accomplish analysis within 10 min. The results demonstrated that LFAs based on the newly produced, highly sensitive, and robust mAb were able to be used for both rapid qualitative screening of the type of poisoning and accurate quantitative determination of the severity of poisoning after accidental ingestion by patients of toxic mushrooms.
Collapse
Affiliation(s)
- Jianyu Zhu
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Leina Dou
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Jiafei Mi
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Yuchen Bai
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Minggang Liu
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Jianzhong Shen
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Wenbo Yu
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| | - Suxia Zhang
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China.
| | - Xuezhi Yu
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China.
| | - Zhanhui Wang
- College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China
| |
Collapse
|
6
|
Rapid, on-site, and sensitive detection of aflatoxin M1 in milk products by using time-resolved fluorescence microsphere test strip. Food Control 2021. [DOI: 10.1016/j.foodcont.2020.107616] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
7
|
Miklós G, Angeli C, Ambrus Á, Nagy A, Kardos V, Zentai A, Kerekes K, Farkas Z, Jóźwiak Á, Bartók T. Detection of Aflatoxins in Different Matrices and Food-Chain Positions. Front Microbiol 2020; 11:1916. [PMID: 32983001 PMCID: PMC7480073 DOI: 10.3389/fmicb.2020.01916] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 07/21/2020] [Indexed: 12/21/2022] Open
Abstract
Aflatoxins, produced mainly by filamentous fungi Aspergillus flavus and Aspergillus parasiticus, are one of the most carcinogenic compounds that have adverse health effects on both humans and animals consuming contaminated food and feed, respectively. Aflatoxin B1 (AFB1) and aflatoxin B2 (AFB2) as well as aflatoxin G1(AFG1) and aflatoxin G2 (AFG2) occur in the contaminated foods and feed. In the case of dairy ruminants, after the consumption of feed contaminated with aflatoxins, aflatoxin metabolites [aflatoxin M1 (AFM1) and aflatoxin M2 (AFM2)] may appear in milk. Because of the health risk and the official maximum limits of aflatoxins, there is a need for application of fast and accurate testing methods. At present, there are several analytical methods applied in practice for determination of aflatoxins. The aim of this review is to provide a guide that summarizes worldwide aflatoxin regulations and analytical methods for determination of aflatoxins in different food and feed matrices, that helps in the decision to choose the most appropriate method that meets the practical requirements of fast and sensitive control of their contamination. Analytical options are outlined from the simplest and fastest methods with the smallest instrument requirements, through separation methods, to the latest hyphenated techniques.
Collapse
Affiliation(s)
- Gabriella Miklós
- Székesfehérvár Regional Food Chain Laboratory, National Food Chain Safety Office, Székesfehérvár, Hungary
| | | | - Árpád Ambrus
- University of Debrecen Doctoral School of Nutrition and Food Sciences, Debrecen, Hungary
| | - Attila Nagy
- Food Chain Safety Laboratory Directorate, National Food Chain Safety Office, Budapest, Hungary
| | - Valéria Kardos
- Food Chain Safety Laboratory Directorate, National Food Chain Safety Office, Budapest, Hungary
| | - Andrea Zentai
- System Management and Supervision Directorate, National Food Chain Safety Office, Budapest, Hungary
| | - Kata Kerekes
- System Management and Supervision Directorate, National Food Chain Safety Office, Budapest, Hungary
| | - Zsuzsa Farkas
- Digital Food Institute, University of Veterinary Medicine Budapest, Budapest, Hungary
| | - Ákos Jóźwiak
- Digital Food Institute, University of Veterinary Medicine Budapest, Budapest, Hungary
| | | |
Collapse
|
8
|
Dual fluorescent immunochromatographic assay for simultaneous quantitative detection of citrinin and zearalenone in corn samples. Food Chem 2020; 336:127713. [PMID: 32768909 DOI: 10.1016/j.foodchem.2020.127713] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 07/23/2020] [Accepted: 07/28/2020] [Indexed: 12/30/2022]
Abstract
The presence of multiple mycotoxins in the agricultural products poses a serious threat to the health of humans and animals. Citrinin (CIT) causes slow growth in animals and damages the kidney function. Zearalenone (ZEN) causes chronic poisoning, abnormal functioning and even death in animals. Herein, a dual fluorescent immunochromatographic assay (DF-ICA) based on europium nanoparticles (EuNPs) was developed for the simultaneous detection of CIT and ZEN in the corn samples. After optimization, the limits of detection (LODs), IC50 and average recoveries for the simultaneous determination of CIT and ZEN were 0.06 and 0.11 ng/mL, 0.35 and 0.76 ng/mL, from 86.3% to 111.6% and from 86.6% to 114.4%, respectively. Moreover, the DF-ICA was validated by high performance liquid chromatography (HPLC) analyses, and a satisfactory consistency was obtained. In brief, this work demonstrates the feasibility of DF-ICA for simultaneous monitoring of CIT and ZEN in the corn samples.
Collapse
|
9
|
Li H, Wang D, Tang X, Zhang W, Zhang Q, Li P. Time-Resolved Fluorescence Immunochromatography Assay (TRFICA) for Aflatoxin: Aiming at Increasing Strip Method Sensitivity. Front Microbiol 2020; 11:676. [PMID: 32435234 PMCID: PMC7219281 DOI: 10.3389/fmicb.2020.00676] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 03/24/2020] [Indexed: 12/19/2022] Open
Abstract
Aflatoxin is the most harmful mycotoxin that is ubiquitous in foods and agro-products. Because of its high toxicity, maximum admissible levels of aflatoxins (AF) is regulated worldwide, and monitoring of their occurrence in several commodities is mandatory for assuring food safety and consumers' health. Considering that the strip method is very simple and convenient for users, in order to enhance strip assay's sensitivity, a lot of time-resolved fluorescence immunochromatography assays (TRFICAs) were developed recently with increasing several times of assay sensitivity compared with traditional gold nanoparticle-based strip assay (GNP-SA). This review briefly describes the newly developed TRFICA for aflatoxin determination, including TRFICA for aflatoxin B1 (AFB1) detection, TRFICA for aflatoxin M1 (AFM1) detection, TRFICA for total aflatoxins (AFB1 + B2 + G1 + G2) detection and the latest identification-nanobody-based TRFICA for aflatoxin detection. The application of TRFICA for aflatoxin detection in different agro-products is also concluded in this review. Reasonably, TRFICA has been becoming one of the most important tool for monitoring aflatoxin in foods and agro-products.
Collapse
Affiliation(s)
- Hui Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, China
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan, China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, China
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, China
| | - Du Wang
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, China
| | - Xiaoqian Tang
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, China
| | - Wen Zhang
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, China
| | - Qi Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, China
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan, China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, China
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, China
| | - Peiwu Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, China
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan, China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, China
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, China
| |
Collapse
|
10
|
Tang X, Zhang Q, Zhang Z, Ding X, Jiang J, Zhang W, Li P. Rapid, on-site and quantitative paper-based immunoassay platform for concurrent determination of pesticide residues and mycotoxins. Anal Chim Acta 2019; 1078:142-150. [PMID: 31358212 DOI: 10.1016/j.aca.2019.06.015] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 06/05/2019] [Accepted: 06/06/2019] [Indexed: 02/02/2023]
Abstract
Mycotoxins and pesticides are prevalent in cereal food. It is difficult to detect these two kinds of hazard factors simultaneously in rapid assay. In order to find a solution to the problem, carbamates and aflatoxins were selected in this study to establish a rapid, on-site, and quantitative paper sensor. Two novel monoclonal antibodies (mAbs) against carbaryl and carbofuran (1D2 and G11) were developed. The IC50 values (half maximal inhibitory concentration) were 0.8 ng/mL and 217.6 ng/mL for carbaryl and carbofuran, respectively. Based on the sensitive and specific mAbs, a multi-TRFICA (time-resolved fluorescence) paper sensor was developed, which simultaneously detected six types of hazardous chemicals, including AFB1, AFB2, AFG1, AFG2, carbaryl, and carbofuran. A universal sample pretreatment method for mycotoxins and pesticides was explored to apply on established competitive indirect enzyme-linked immunosorbent assay (icELISA) and multi-TRFICA-paper sensor. The established paper sensor can be easily observed with naked eyes, qualitatively under a UV lamp, and quantitated using a home-made device. It exhibited a calculated limit of quantity for AFTs, carbaryl, and carbofuran of 0.03, 0.02, and 60.2 ng/mL in corn samples, respectively. The spiking-recoveries and real sample studies proved that multi-TRFICA-paper sensor is an accurate, sensitive, and high throughput detection method for simple and low-cost analysis in corn samples.
Collapse
Affiliation(s)
- Xiaoqian Tang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, 430062, China; Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, 430062, China; Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan, 430062, China; Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, 430062, China; Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, 430062, China
| | - Qi Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, 430062, China; Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan, 430062, China; Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, 430062, China
| | - Zhaowei Zhang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, 430062, China; Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, 430062, China
| | - Xiaoxia Ding
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan, 430062, China
| | - Jun Jiang
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, 430062, China
| | - Wen Zhang
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, 430062, China
| | - Peiwu Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, 430062, China; Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, 430062, China; Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan, 430062, China; Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, 430062, China; Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan, 430062, China.
| |
Collapse
|
11
|
Li Y, Zhou Y, Chen X, Huang X, Xiong Y. Comparison of three sample addition methods in competitive and sandwich colloidal gold immunochromatographic assay. Anal Chim Acta 2019; 1094:90-98. [PMID: 31761051 DOI: 10.1016/j.aca.2019.09.079] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 09/23/2019] [Accepted: 09/28/2019] [Indexed: 01/08/2023]
Abstract
Immunochromatographic assays (ICAs) are mainstream point-of-care diagnostic tools in disease control, food safety, and environmental monitoring. However, the important issue pertaining to the influence of sample addition methods on the detection performance of ICAs has not been addressed, and related information is still lacking. Herein, we selected the well-accepted gold nanoparticles (AuNPs) as visual labels. AuNP-based ICA was then used to explore the effects of three sample addition methods (i.e., dry, wet, and insert) on the analytical performance of ICAs by using competitive and sandwich models. Under optimized conditions, the competitive ICA with clenbuterol as an analyte showed a negligible difference (p > 0.05) in the detection performance of the three methods in ideal phosphate buffered saline solution. However, the wet method demonstrated the worst performance in pork samples (p < 0.05). The sandwich ICA strip with human chorionic gonadotropin as an analyte revealed the significantly different analytical performances of the three approaches in phosphate buffer (PB) solution and spiked serum (p < 0.05). Two independent linear correlations were observed with the increase in target concentration. However, for the wet method in the PB solution and serum, the first linear correlation was at a relatively narrow target concentration range, and the second linear correlation was at a wider concentration range compared with those for the dry and insert methods. Our findings demonstrated that sample addition methods slightly influence competitive ICAs (p > 0.05) but remarkably affect sandwich ICAs (p < 0.05). We believe that this study can further explain the differences in detection results for the same target analyte in actual ICA detection. The results may serve as a reference in the rational selection of the appropriate sample addition method for succeeding ICA works.
Collapse
Affiliation(s)
- Yu Li
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China; School of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Yaofeng Zhou
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China; School of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Xirui Chen
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China; School of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Xiaolin Huang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China; School of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China.
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China; School of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China; Jiangxi-OAI Joint Research Institute, Nanchang University, Nanchang, 330047, PR China.
| |
Collapse
|
12
|
Chen Y, Huang Z, Hu S, Zhang G, Peng J, Xia J, Lai W. Integrated immunochromatographic assay for qualitative and quantitative detection of clenbuterol. Anal Biochem 2019; 577:45-51. [PMID: 31022377 DOI: 10.1016/j.ab.2019.04.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 01/25/2019] [Accepted: 04/16/2019] [Indexed: 01/08/2023]
Abstract
In this study, colloidal gold (CG) and time-resolved fluorescent nanobead (TRFN) probes were used to establish an integrated immunochromatographic assay (ICA) to qualitatively and quantitatively detect clenbuterol (CLE). The best experimental conditions for the two probes in separate ICAs were obtained by optimizing the antibody labeling concentration, the amount of antigen, and the concentration of probe. When the CG and TRFN probes co-existed in the ICA, the latter had no effect on the sensitivity of qualitative detection of the CG probe-based ICA. However, the CG probe optimized the linear range of quantitative detection in the TRFN probe-based ICA. The integrated test strip can be used for qualitative and quantitative detection of CLE in one step. When the amount of antigen reached 0.4 mg/mL, the CG probe concentration reached 1.2 μg/mL, and the TRFN probe concentration reached 0.68 μg/mL. The qualitative sensitivity of the integrated ICA was 0.5 ng/mL and its quantitative limit of detection was 0.04 ng/mL with a detection range of 0.1-2.7 ng/mL. This developed method is of great significance for large-scale samples screening and positive monitoring in the field of food safety testing.
Collapse
Affiliation(s)
- Yuan Chen
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Zhen Huang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Song Hu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Ganggang Zhang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Juan Peng
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China
| | - Jun Xia
- Jiangxi Province Institute of Veterinary Drug and Food Control, China.
| | - Weihua Lai
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, China.
| |
Collapse
|
13
|
Wang D, Zhang Z, Zhang Q, Wang Z, Zhang W, Yu L, Li H, Jiang J, Li P. Rapid and sensitive double-label based immunochromatographic assay for zearalenone detection in cereals. Electrophoresis 2019; 39:2125-2130. [PMID: 29808596 DOI: 10.1002/elps.201800055] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Revised: 05/05/2018] [Accepted: 05/16/2018] [Indexed: 12/30/2022]
Abstract
A double-label immunochromatographic based assay (DL-ICA) was developed to monitor zearalenone (ZEN) levels in cereals, based on Eu3+ nanoparticles (EuNP). The DL-ICA exhibited excellent sensitivity, reliability and selectivity in real samples. It showed low limits of detection (0.21-0.25 μg/kg) and broad analytical ranges (up to 120 μg/kg). The total analytical time, including sample preparation and DL-ICA execution, was reduced by 15 min compared with HPLC. The recovery rates ranged from 95.0-118.4%, with relative standard deviations (RSD) <11.6%. Inter- and intra-day validations were assessed, recovery rates of 89.3-106.9% and RSD of 2.3-9.7% were obtained, suggesting considerable stability and reliability for the assay. An excellent correlation was observed between DL-ICA and a reference HPLC method (R2 = 0.9899). Compared to current immunoassays, the current DL-ICA is inexpensive, highly sensitive, and rapid. Therefore, DL-ICA constitutes a novel tool for monitoring mycotoxins in food and feed to ensure safety.
Collapse
Affiliation(s)
- Du Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China.,National Reference Laboratory for Biotoxin Test, Wuhan, P. R. China
| | - Zhaowei Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China.,Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, P. R. China
| | - Qi Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China.,Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, P. R. China.,Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, P. R. China
| | - Zhongzheng Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China
| | - Wen Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China.,Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, P. R. China.,National Reference Laboratory for Biotoxin Test, Wuhan, P. R. China
| | - Li Yu
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China.,National Reference Laboratory for Biotoxin Test, Wuhan, P. R. China
| | - Hui Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China.,Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, P. R. China
| | - Jun Jiang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China.,Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan, P. R. China
| | - Peiwu Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan, P. R. China.,Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan, P. R. China.,Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan, P. R. China.,Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan, P. R. China
| |
Collapse
|
14
|
|
15
|
Wang D, Zhu J, Zhang Z, Zhang Q, Zhang W, Yu L, Jiang J, Chen X, Wang X, Li P. Simultaneous Lateral Flow Immunoassay for Multi-Class Chemical Contaminants in Maize and Peanut with One-Stop Sample Preparation. Toxins (Basel) 2019; 11:E56. [PMID: 30669515 PMCID: PMC6356774 DOI: 10.3390/toxins11010056] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 01/17/2019] [Accepted: 01/17/2019] [Indexed: 12/26/2022] Open
Abstract
Multi-class chemical contaminants, such as pesticides and mycotoxins, are recognized as the major risk factors in agro products. It is thus necessary to develop rapid and simple sensing methods to fulfill the on-site monitoring of multi-class chemical contaminants with different physicochemical properties. Herein, a lateral flow immunoassay via time-resolved fluorescence was developed for the rapid, on-site, simultaneous, and quantitative sensing aflatoxin B₁ (AFB₁), zearalenone (ZEA), and chlorothalonil (CTN) in maize and peanut. The sample preparation was optimized to a single step, combining the grinding and extraction. Under optimal conditions, the sensing method lowered the limits of detection (LOD) to 0.16, 0.52, and 1.21 µg/kg in maize and 0.18, 0.57, and 1.47 µg/kg in peanut with an analytical range of 0.48⁻20, 1.56⁻200, and 3.63⁻300 µg/kg for AFB₁, ZEA and CTN, respectively. The protocol could be completed within 15 min, including sample preparation and lateral flow immunoassay. The recovery range was 83.24⁻110.80%. An excellent correlation was observed between this approach and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) for mycotoxins and gas chromatography-tandem mass spectrometry (GC-MS/MS) for pesticide in maize and peanut. This work could be applied in on-site multi-class sensing for food safety.
Collapse
Affiliation(s)
- Du Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Quality Inspection and Test Center for Oilseeds Products, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
| | - Jianguo Zhu
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
| | - Zhaowei Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
| | - Qi Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
| | - Wen Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Quality Inspection and Test Center for Oilseeds Products, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
| | - Li Yu
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
| | - Jun Jiang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
| | - Xiaomei Chen
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
| | - Xuefang Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
| | - Peiwu Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture and Rural Affairs, Wuhan 430062, China.
| |
Collapse
|
16
|
Chen W, Huang Z, Hu S, Peng J, Liu D, Xiong Y, Xu H, Wei H, Lai W. Invited review: Advancements in lateral flow immunoassays for screening hazardous substances in milk and milk powder. J Dairy Sci 2019; 102:1887-1900. [PMID: 30660416 DOI: 10.3168/jds.2018-15462] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2018] [Accepted: 11/11/2018] [Indexed: 12/17/2022]
Abstract
Dairy-related food safety outbreaks, such as food-borne pathogen contamination, mycotoxin contamination, and veterinary drug contamination, sometimes happen and have been reported all over the world, affecting human health and, in some cases, leading to death. Thus, rapid yet robust detection methods are needed to monitor milk and milk powder for the presence of hazardous substances. The lateral flow immunoassay (LFI) is widely used in onsite testing because of its rapidity, simplicity, and convenience. In this review, we describe some traditional LFI used to detect hazardous substances in milk and milk powder. Furthermore, we discuss recent advances in LFI that aim to improve sensitivity or detection efficiency. These advances include the use of novel label materials, development of signal amplification systems, design of multiplex detection systems, and the use of nucleic acid-based LFI.
Collapse
Affiliation(s)
- Wenyao Chen
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Zheng Huang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Song Hu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Juan Peng
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Daofeng Liu
- Jiangxi Province Center for Disease Control and Prevention, Nanchang 330047, China
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Hengyi Xu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Hua Wei
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Weihua Lai
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China.
| |
Collapse
|
17
|
Thin Films Sensor Devices for Mycotoxins Detection in Foods: Applications and Challenges. CHEMOSENSORS 2019. [DOI: 10.3390/chemosensors7010003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Mycotoxins are a group of secondary metabolites produced by different species of filamentous fungi and pose serious threats to food safety due to their serious human and animal health impacts such as carcinogenic, teratogenic and hepatotoxic effects. Conventional methods for the detection of mycotoxins include gas chromatography and high-performance liquid chromatography coupled with mass spectrometry or other detectors (fluorescence or UV detection), thin layer chromatography and enzyme-linked immunosorbent assay. These techniques are generally straightforward and yield reliable results; however, they are time-consuming, require extensive preparation steps, use large-scale instruments, and consume large amounts of hazardous chemical reagents. Rapid detection of mycotoxins is becoming an increasingly important challenge for the food industry in order to effectively enforce regulations and ensure the safety of food and feed. In this sense, several studies have been done with the aim of developing strategies to detect mycotoxins using sensing devices that have high sensitivity and specificity, fast analysis, low cost and portability. The latter include the use of microarray chips, multiplex lateral flow, Surface Plasmon Resonance, Surface Enhanced Raman Scattering and biosensors using nanoparticles. In this perspective, thin film sensors have recently emerged as a good candidate technique to meet such requirements. This review summarizes the application and challenges of thin film sensor devices for detection of mycotoxins in food matrices.
Collapse
|
18
|
Li G, Xu L, Wu W, Wang D, Jiang J, Chen X, Zhang W, Poapolathep S, Poapolathep A, Zhang Z, Zhang Q, Li P. On-Site Ultrasensitive Detection Paper for Multiclass Chemical Contaminants via Universal Bridge-Antibody Labeling: Mycotoxin and Illegal Additives in Milk as an Example. Anal Chem 2018; 91:1968-1973. [PMID: 30509070 DOI: 10.1021/acs.analchem.8b04290] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Guanghua Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, People’s Republic of China
| | - Lin Xu
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, People’s Republic of China
| | - Wenqin Wu
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, People’s Republic of China
| | - Du Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, People’s Republic of China
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
- Natonal Reference for Biotoxin Detection, Wuhan 430062, People’s Republic of China
| | - Jun Jiang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, People’s Republic of China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
| | - Xiaomei Chen
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, People’s Republic of China
| | - Wen Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, People’s Republic of China
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
- Natonal Reference for Biotoxin Detection, Wuhan 430062, People’s Republic of China
| | - Saranya Poapolathep
- Department of Pharmacology, Faculty of Veterinary Medicine, Kasetsart University, Bangkok 10900, Thailand
| | - Amnart Poapolathep
- Department of Pharmacology, Faculty of Veterinary Medicine, Kasetsart University, Bangkok 10900, Thailand
| | - Zhaowei Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, People’s Republic of China
| | - Qi Zhang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
- Natonal Reference for Biotoxin Detection, Wuhan 430062, People’s Republic of China
| | - Peiwu Li
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, People’s Republic of China
- Natonal Reference for Biotoxin Detection, Wuhan 430062, People’s Republic of China
| |
Collapse
|
19
|
Pérez E, Marco FM, Martínez-Peinado P, Mora J, Grindlay G. Evaluation of different competitive immunoassays for aflatoxin M 1 determination in milk samples by means of inductively coupled plasma mass spectrometry. Anal Chim Acta 2018; 1049:10-19. [PMID: 30612640 DOI: 10.1016/j.aca.2018.11.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 11/09/2018] [Accepted: 11/12/2018] [Indexed: 11/29/2022]
Abstract
Haptens (i.e. biomolecules which molecular weight is lower than 10 kDa) determination by inductively coupled plasma mass spectrometry (ICP-MS) is usually performed by means of competitive immunoassays. In these immunoassays, analyte quantification is indirectly carried out using two different tracer species (i.e. antibodies or antigen-protein conjugates). However, the benefits (and drawbacks) derived from using a given tracer species have not been systematically investigated so far. The goal of this work is to evaluate the influence of the tracer species employed in competitive immunoassays on the analytical figures of merit for aflatoxin M1 (AFM1) determination in milk samples. To this end, three different strategies have been developed and evaluated, namely: (i) antibody binding inhibition assay (ABIA); (ii) capture inhibition assay (CIA); and (iii) capture bridge inhibition assay (CBIA). Experimental results show that the use of the antibody as tracer species (as in the ABIA approach) affords better analytical figures of merit for AFM1 determination than using the antigen-protein conjugate as the tracer one (as in the CIA and CBIA strategies). The limit of detection afforded by ABIA strategy (i.e. 0.1 ng kg-1) for AFM1 determination was 1000-fold and 50-fold lower regarding the CIA and CBIA strategies, respectively. In the case of the ABIA approach, the characteristics of the metal nanoparticle label employed to detect the tracer species is critical on the analytical figures of merit. However, when the hapten-protein conjugates are used as tracer species, immunocomplex formation is severely hampered by steric effects caused by the protein moiety and, consequently, the characteristics of the metal nanoparticle label is not critical in the immunoassay performance. The different immunoassay strategies were successfully validated for AFM1 determination in milk samples using a certified reference material of whole milk powder (ERM-BD283) according to European Conformity guidelines for analytical methods of food contaminants and mycotoxins. Compared to ELISA, the immunoassay developed for AFM1 determination in milk samples improve limits of detection up to 10-fold.
Collapse
Affiliation(s)
- Emma Pérez
- Department of Analytical Chemistry, Nutrition and Food Sciences, University of Alicante, PO Box 99, 03080, Alicante, Spain
| | - Francisco M Marco
- Department of Biotechnology, University of Alicante, PO Box 99, 03080, Alicante, Spain
| | | | - Juan Mora
- Department of Analytical Chemistry, Nutrition and Food Sciences, University of Alicante, PO Box 99, 03080, Alicante, Spain
| | - Guillermo Grindlay
- Department of Analytical Chemistry, Nutrition and Food Sciences, University of Alicante, PO Box 99, 03080, Alicante, Spain.
| |
Collapse
|
20
|
Li G, Wang D, Zhou A, Sun Y, Zhang Q, Poapolathep A, Zhang L, Fan Z, Zhang Z, Li P. Rapid, On-Site, Ultrasensitive Melamine Quantitation Method for Protein Beverages Using Time-Resolved Fluorescence Detection Paper. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2018; 66:5671-5676. [PMID: 29719144 DOI: 10.1021/acs.jafc.8b01016] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
To ensure protein beverage safety and prevent illegal melamine use to artificially increase protein content, a rapid, on-site, ultrasensitive detection method for melamine must be developed because melamine is detrimental to human health. Herein, an ultrasensitive time-resolved fluorescence detection paper (TFDP) was developed to detect melamine in protein beverages within 15 min using a one-step sample preparation. The lower limits of detection were 0.89, 0.94, and 1.05 ng/mL, and the linear ranges were 2.67-150, 2.82-150, and 3.15-150 ng/mL (R2 > 0.982) for peanut, walnut, and coconut beverages, respectively. The recovery rates were 85.86-110.60% with a coefficient of variation <7.80% in the spiking experiment. A high specificity was observed in the interferent experiment. When detecting real protein beverage samples, the TFDP and ultraperformance liquid chromatography-tandem mass spectrometer (UPLC-MS/MS) results were consistent. This method is a promising alternative for rapid, on-site detection of melamine in beverages.
Collapse
Affiliation(s)
- Guanghua Li
- School of Materials Science and Engineering , Wuhan Institute of Technology , Wuhan 430074 , P. R. China
| | - Du Wang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, Laboratory of Risk Assessment for Oilseeds Products, and National Reference Laboratory for Biotoxin Test , Ministry of Agriculture, Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences , Wuhan 430062 , P. R. China
| | - Aijun Zhou
- School of Materials Science and Engineering , Wuhan Institute of Technology , Wuhan 430074 , P. R. China
| | - Yimin Sun
- School of Materials Science and Engineering , Wuhan Institute of Technology , Wuhan 430074 , P. R. China
| | - Qi Zhang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, Laboratory of Risk Assessment for Oilseeds Products, and National Reference Laboratory for Biotoxin Test , Ministry of Agriculture, Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences , Wuhan 430062 , P. R. China
| | - Amnart Poapolathep
- Department of Pharmacology, Faculty of Veterinary Medicine , Kasetsart University , Bangkok , 10900 , Thailand
| | - Li Zhang
- Hubei Provincial Institute for Food Supervision , Wuhan 430075 , P. R. China
| | - Zhiyong Fan
- Hubei Provincial Institute for Food Supervision , Wuhan 430075 , P. R. China
| | - Zhaowei Zhang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, Laboratory of Risk Assessment for Oilseeds Products, and National Reference Laboratory for Biotoxin Test , Ministry of Agriculture, Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences , Wuhan 430062 , P. R. China
| | - Peiwu Li
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Key Laboratory of Detection for Mycotoxins, Laboratory of Risk Assessment for Oilseeds Products, and National Reference Laboratory for Biotoxin Test , Ministry of Agriculture, Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences , Wuhan 430062 , P. R. China
| |
Collapse
|
21
|
Li H, Yang D, Li P, Zhang Q, Zhang W, Ding X, Mao J, Wu J. Palladium Nanoparticles-Based Fluorescence Resonance Energy Transfer Aptasensor for Highly Sensitive Detection of Aflatoxin M₁ in Milk. Toxins (Basel) 2017; 9:toxins9100318. [PMID: 29027938 PMCID: PMC5666365 DOI: 10.3390/toxins9100318] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 10/05/2017] [Accepted: 10/06/2017] [Indexed: 12/21/2022] Open
Abstract
A highly sensitive aptasensor for aflatoxin M1 (AFM1) detection was constructed based on fluorescence resonance energy transfer (FRET) between 5-carboxyfluorescein (FAM) and palladium nanoparticles (PdNPs). PdNPs (33 nm) were synthesized through a seed-mediated growth method and exhibited broad and strong absorption in the whole ultraviolet-visible (UV-Vis) range. The strong coordination interaction between nitrogen functional groups of the AFM1 aptamer and PdNPs brought FAM and PdNPs in close proximity, which resulted in the fluorescence quenching of FAM to a maximum extent of 95%. The non-specific fluorescence quenching caused by PdNPs towards fluorescein was negligible. After the introduction of AFM1 into the FAM-AFM1 aptamer-PdNPs FRET system, the AFM1 aptamer preferentially combined with AFM1 accompanied by conformational change, which greatly weakened the coordination interaction between the AFM1 aptamer and PdNPs. Thus, fluorescence recovery of FAM was observed and a linear relationship between the fluorescence recovery and the concentration of AFM1 was obtained in the range of 5–150 pg/mL in aqueous buffer with the detection limit of 1.5 pg/mL. AFM1 detection was also realized in milk samples with a linear detection range from 6 pg/mL to 150 pg/mL. The highly sensitive FRET aptasensor with simple configuration shows promising prospect in detecting a variety of food contaminants.
Collapse
Affiliation(s)
- Hui Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
| | - Daibin Yang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| | - Peiwu Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan 430062, China.
| | - Qi Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan 430062, China.
| | - Wen Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan 430062, China.
| | - Xiaoxia Ding
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan 430062, China.
| | - Jin Mao
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
| | - Jing Wu
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
| |
Collapse
|
22
|
Tang X, Li P, Zhang Q, Zhang Z, Zhang W, Jiang J. Time-Resolved Fluorescence Immunochromatographic Assay Developed Using Two Idiotypic Nanobodies for Rapid, Quantitative, and Simultaneous Detection of Aflatoxin and Zearalenone in Maize and Its Products. Anal Chem 2017; 89:11520-11528. [PMID: 28901744 DOI: 10.1021/acs.analchem.7b02794] [Citation(s) in RCA: 100] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Xiaoqian Tang
- Oil
Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
- Key
Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China
- Key
Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan 430062, China
| | - Peiwu Li
- Oil
Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
- Key
Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China
- Key
Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China
- Quality Inspection & Test Center for Oilseed Products, Ministry of Agriculture, Wuhan 430062, China
| | - Qi Zhang
- Key
Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China
| | - Zhaowei Zhang
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China
| | - Wen Zhang
- Oil
Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
- Key
Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China
- Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China
| | - Jun Jiang
- Oil
Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
| |
Collapse
|
23
|
Ouyang S, Zhang Z, He T, Li P, Zhang Q, Chen X, Wang D, Li H, Tang X, Zhang W. An On-Site, Ultra-Sensitive, Quantitative Sensing Method for the Determination of Total Aflatoxin in Peanut and Rice Based on Quantum Dot Nanobeads Strip. Toxins (Basel) 2017; 9:137. [PMID: 28406451 PMCID: PMC5408211 DOI: 10.3390/toxins9040137] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 03/23/2017] [Accepted: 04/06/2017] [Indexed: 12/16/2022] Open
Abstract
An on-site, ultra-sensitive, and quantitative sensing method was developed based on quantum dot nanobeads (QDNBs) and a test strip for the determination of total aflatoxins (AFTs) in rice and peanuts. The monoclonal antibody against AFT (mAbAFT) was homemade and labeled with QDNB. After the pre-coating of the AFT antigen on the test line (T line), the competitive immunoreactions were conducted between AFT and AFT antigen on the T line with QDNBs-mAbAFT. Under optimal conditions, this approach allowed a rapid response towards AFT with a considerable sensitivity of 1.4 pg/mL and 2.9 pg/mL in rice and peanut matrices, respectively. The put-in and put-out durations were within 10 min. The recoveries for AFT in rice and peanut sample matrices were recorded from 86.25% to 118.0%, with relative deviations (RSD) below 12%. The assay was further validated via the comparison between this QDNB strip and the conventional HPLC method using spiked samples. Thus, the design provided a potential alternative for on-site, ultra-sensitive, and quantitative sensing of AFT that could also be expanded to other chemical contaminants for food safety.
Collapse
Affiliation(s)
- Suiyan Ouyang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| | - Zhaowei Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| | - Ting He
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
| | - Peiwu Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| | - Qi Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
| | - Xiaomei Chen
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| | - Du Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
| | - Hui Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
| | - Xiaoqian Tang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| | - Wen Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| |
Collapse
|
24
|
Guo M, Zhou B, Huang Z, Zhao C, Zhang J, Huang B. A New Method for Determination of Alfatoxin M1 in Milk by Ultrasensitive Time-Resolved Fluoroimmunoassay. FOOD ANAL METHOD 2017. [DOI: 10.1007/s12161-017-0850-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
25
|
Gong X, Cai J, Zhang B, Zhao Q, Piao J, Peng W, Gao W, Zhou D, Zhao M, Chang J. A review of fluorescent signal-based lateral flow immunochromatographic strips. J Mater Chem B 2017; 5:5079-5091. [DOI: 10.1039/c7tb01049d] [Citation(s) in RCA: 104] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Fluorescent signal-based lateral flow immunochromatographic strips (FLFICS) have received great expectations since they combine the quantitative sensitivity of fluorescence analysis and the simplicity, rapidness, and portability of a common lateral flow immunochromatographic strip (LFICS).
Collapse
|
26
|
Hu LM, Luo K, Xia J, Xu GM, Wu CH, Han JJ, Zhang GG, Liu M, Lai WH. Advantages of time-resolved fluorescent nanobeads compared with fluorescent submicrospheres, quantum dots, and colloidal gold as label in lateral flow assays for detection of ractopamine. Biosens Bioelectron 2016; 91:95-103. [PMID: 28006689 DOI: 10.1016/j.bios.2016.12.030] [Citation(s) in RCA: 108] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 12/06/2016] [Accepted: 12/12/2016] [Indexed: 01/12/2023]
Abstract
Label selection is a critical factor for improving the sensitivity of lateral flow assay. Time-resolved fluorescent nanobeads, fluorescent submicrospheres, quantum dots, and colloidal gold-based lateral flow assay (TRFN-LFA, FM-LFA, QD-LFA, and CG-LFA) were first systematically compared for the quantitative detection of ractopamine in swine urine based on competitive format. The limits of detection (LOD) of TRFN-LFA, FM-LFA, QD-LFA, and CG-LFA were 7.2, 14.7, 23.6, and 40.1pg/mL in swine urine samples, respectively. The sensitivity of TRFN-LFA was highest. In the quantitative determination of ractopamine (RAC) in swine urine samples, TRFN-LFA exhibited a wide linear range of 5pg/mL to 2500pg/mL with a reliable coefficient of correlation (R2=0.9803). Relatively narrow linear ranges of 10-500pg/mL (FM-LFA) and 25-2500pg/mL (QD-LFA and CG-LFA) were acquired. Approximately 0.005µg of anti-RAC poly antibody (pAb) was used in each TRFN-LFA test strip, whereas 0.02, 0.054, and 0.15µg of pAb were used in each of the FM-LFA, QD-LFA, and CG-LFA test strips, respectively. In addition, TRFN-LFA required the least RAC-BSA antigens and exhibited the shortest detection time compared with the other lateral flow assays. Analysis of the RAC in swine urine samples showed that the result of TRFN-LFA was consistent with that of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and a commercial enzyme-linked immunosorbent assay (ELISA) kit.
Collapse
Affiliation(s)
- Li-Ming Hu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Kai Luo
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Jun Xia
- Jiangxi Institute of Veterinary Drug and Feedstuff Control, Nanchang 330047, China
| | - Guo-Mao Xu
- Jiangxi Institute of Veterinary Drug and Feedstuff Control, Nanchang 330047, China
| | - Cheng-Hui Wu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Jiao-Jiao Han
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Gang-Gang Zhang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Miao Liu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Wei-Hua Lai
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China.
| |
Collapse
|
27
|
Direct and ultrasensitive optofluidic-based immunosensing assay of aflatoxin M1 in dairy products using organic solvent extraction. Anal Chim Acta 2016; 940:120-7. [DOI: 10.1016/j.aca.2016.08.020] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 08/01/2016] [Accepted: 08/09/2016] [Indexed: 02/07/2023]
|
28
|
Xu L, Zhang Z, Zhang Q, Li P. Mycotoxin Determination in Foods Using Advanced Sensors Based on Antibodies or Aptamers. Toxins (Basel) 2016; 8:239. [PMID: 27529281 PMCID: PMC4999855 DOI: 10.3390/toxins8080239] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2015] [Revised: 07/08/2016] [Accepted: 07/08/2016] [Indexed: 12/24/2022] Open
Abstract
Mycotoxin contamination threatens health and life of humans and animals throughout the food supply chains. Many of the mycotoxins have been proven to be carcinogens, teratogens and mutagens. The reliable and sensitive sensing methods are requested to monitor mycotoxin contamination. Advanced sensors based on antibodies or aptamers boast the advantages of high sensitivity and rapidity, and have been used in the mycotoxin sensing. These sensors are miniaturized, thereby lowering costs, and are applicable to high-throughput modes. In this work, the latest developments in sensing strategies for mycotoxin determination were critically discussed. Optical and electrochemical sensing modes were compared. The sensing methods for single mycotoxin or multiple mycotoxins in food samples were reviewed, along with the challenges and the future of antibody or aptamer-based sensors. This work might promote academic studies and industrial applications for mycotoxin sensing.
Collapse
Affiliation(s)
- Lin Xu
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
| | - Zhaowei Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
| | - Qi Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Laboratory of Risk Assessment for oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| | - Peiwu Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Laboratory of Risk Assessment for oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
- Quality Inspection and Test Center for oilseeds Products, Ministry of Agriculture, Wuhan 430062, China.
| |
Collapse
|
29
|
Wang D, Zhang Z, Li P, Zhang Q, Zhang W. Time-Resolved Fluorescent Immunochromatography of Aflatoxin B1 in Soybean Sauce: A Rapid and Sensitive Quantitative Analysis. SENSORS 2016; 16:s16071094. [PMID: 27428975 PMCID: PMC4970140 DOI: 10.3390/s16071094] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/01/2016] [Revised: 06/08/2016] [Accepted: 07/06/2016] [Indexed: 12/22/2022]
Abstract
Rapid and quantitative sensing of aflatoxin B1 with high sensitivity and specificity has drawn increased attention of studies investigating soybean sauce. A sensitive and rapid quantitative immunochromatographic sensing method was developed for the detection of aflatoxin B1 based on time-resolved fluorescence. It combines the advantages of time-resolved fluorescent sensing and immunochromatography. The dynamic range of a competitive and portable immunoassay was 0.3-10.0 µg·kg(-1), with a limit of detection (LOD) of 0.1 µg·kg(-1) and recoveries of 87.2%-114.3%, within 10 min. The results showed good correlation (R² > 0.99) between time-resolved fluorescent immunochromatographic strip test and high performance liquid chromatography (HPLC). Soybean sauce samples analyzed using time-resolved fluorescent immunochromatographic strip test revealed that 64.2% of samples contained aflatoxin B1 at levels ranging from 0.31 to 12.5 µg·kg(-1). The strip test is a rapid, sensitive, quantitative, and cost-effective on-site screening technique in food safety analysis.
Collapse
Affiliation(s)
- Du Wang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Quality Inspection and Test Center for Oilseeds Products, Ministry of Agriculture, Wuhan 430062, China.
| | - Zhaowei Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
| | - Peiwu Li
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture, Wuhan 430062, China.
| | - Qi Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China.
| | - Wen Zhang
- Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Wuhan 430062, China.
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China.
- Quality Inspection and Test Center for Oilseeds Products, Ministry of Agriculture, Wuhan 430062, China.
| |
Collapse
|
30
|
Zhang Z, Hu X, Zhang Q, Li P. Determination for multiple mycotoxins in agricultural products using HPLC–MS/MS via a multiple antibody immunoaffinity column. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1021:145-152. [PMID: 26948441 DOI: 10.1016/j.jchromb.2016.02.035] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Revised: 02/23/2016] [Accepted: 02/23/2016] [Indexed: 12/29/2022]
|
31
|
Wang D, Zhang Z, Li P, Zhang Q, Ding X, Zhang W. Europium Nanospheres-Based Time-Resolved Fluorescence for Rapid and Ultrasensitive Determination of Total Aflatoxin in Feed. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2015; 63:10313-10318. [PMID: 26565941 DOI: 10.1021/acs.jafc.5b03746] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Immunochromatographic (IC) assays are considered suitable diagnostic tools for the determination of mycotoxins. A europium nanospheres-based time-resolved fluorescence immunoassay (Eu-Nano-TRFIA), based on a monoclonal antibody and a portable TRFIA reader, was developed to determine total aflatoxin (including aflatoxins B1, B2, G1, and G2) levels in feed samples. Under optimized conditions, the Eu-Nano-TRFIA method detected total aflatoxin within 12 min. It showed good linearity (R(2) > 0.985), LOD of 0.16 μg/kg, a wide dynamic range of 0.48-30.0 μg/kg, recovery rates of 83.9-113.9%, and coefficients of variation (CVs) of 3.5-8.8%. In the 397 samples from company and livestock farms throughout China, the detection rate was 78.3%, concentrations were 0.50-145.30 μg/kg, the highest total aflatoxin content was found in cottonseed meal, and corn was found to be the most commonly contaminated feed. This method could be a powerful alternative for the rapid and ultrasensitive determination of total aflatoxin in quality control and meet the required Chinese maximum residue limits.
Collapse
Affiliation(s)
- Du Wang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences , Wuhan 430062, China
| | - Zhaowei Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences , Wuhan 430062, China
| | - Peiwu Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences , Wuhan 430062, China
| | - Qi Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences , Wuhan 430062, China
| | - Xiaoxia Ding
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences , Wuhan 430062, China
| | - Wen Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences , Wuhan 430062, China
| |
Collapse
|
32
|
Quesada-González D, Merkoçi A. Nanoparticle-based lateral flow biosensors. Biosens Bioelectron 2015; 73:47-63. [DOI: 10.1016/j.bios.2015.05.050] [Citation(s) in RCA: 316] [Impact Index Per Article: 35.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Revised: 05/15/2015] [Accepted: 05/22/2015] [Indexed: 12/14/2022]
|
33
|
Luo L, Yang JY, Xiao ZL, Zeng DP, Li YJ, Shen YD, Sun YM, Lei HT, Wang H, Xu ZL. A sensitivity-enhanced heterologous immunochromatographic assay based on a monoclonal antibody for the rapid detection of histamine in saury samples. RSC Adv 2015. [DOI: 10.1039/c5ra15925c] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
An immunochromatograhic strip for rapid detection of histamine based on a sensitive monoclonal antibody against p-nitrobenzoylated histamine was firstly reported.
Collapse
Affiliation(s)
- Lin Luo
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
| | - Jin-Yi Yang
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
| | - Zhi-Li Xiao
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
| | - Dao-Ping Zeng
- Guangzhou Wanlian Biotechnologies Co. Ltd
- Guangzhou 510670
- China
| | - Yong-Jun Li
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
- Zhongshan Quality Supervision & Inspection Institute of Agricultural Products
| | - Yu-Dong Shen
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
| | - Yuan-Ming Sun
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
| | - Hong-Tao Lei
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
| | - Hong Wang
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
| | - Zhen-Lin Xu
- Guangdong Provincial Key Laboratory of Food Quality and Safety
- South China Agricultural University
- Guangzhou 510642
- China
| |
Collapse
|