1
|
Cao Y, Wang Q, Han M, Zhang Y, Yuan Z, Zhuo K, Zhang H, Xing Z, Jin H, Zhao C. A smartphone-based multichannel magnetoelastic immunosensor for acute aortic dissection supplementary diagnosis. Talanta 2025; 281:126915. [PMID: 39305762 DOI: 10.1016/j.talanta.2024.126915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 09/03/2024] [Accepted: 09/17/2024] [Indexed: 10/25/2024]
Abstract
Some biomarkers of acute aortic dissection (AAD) can be used for the potential supplementary diagnosis of AAD, such as C-reactive protein (CRP), smooth muscle myosin heavy chain (SmMHC), and D-dimer (D-D). However, the current measurement methods for common markers primarily rely on sophisticated instruments. The operation process is complicated, and the reagents used are expensive. To provide chronic disease monitoring and home self-examination services for potential AAD patients in real time, we developed a smartphone-based multichannel magnetoelastic (ME) immunosensing device to detect protein levels. Our immunosensor reduced the aforementioned restrictions and demonstrated excellent performance for the supplementary diagnosis of AAD. In this paper, we successfully combined the intelligent terminal with the hardware system to sample the resonance frequency shift (RFS) on the multichannel ME immunosensor. According to the target detection objects with their respective antibodies in the immune binding response, multiple experiments were conducted to detect multiple groups of samples, and we found that a CRP concentration, a SmMHC concentration, and a D-D concentration in the range of 0.1-100μg/mL, 1-4ng/mL, and 0.25-5μg/mL were linearly proportional to the RFS of the ME immunosensor, respectively. For CRP, SmMHC, and D-D, the sensitivities were 13.37Hz/μg∙mL-1, 155.19Hz/ng∙mL-1, and 332.72Hz/μg∙mL-1, respectively, and the detection limits were 2.634×10-3μg/mL, 1.155×10-2ng/mL, and 3.687×10-3μg/mL, respectively. The experiments demonstrated that the accuracy and stability of our device were comparable to those of the vector network analyzer (VNA, Calibration instrument).
Collapse
Affiliation(s)
- Yunmei Cao
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China; Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Qiannan Wang
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China; Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Mengshu Han
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China; Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Yunxuan Zhang
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China; Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Zhongyun Yuan
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China; Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China.
| | - Kai Zhuo
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China; Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Hongpeng Zhang
- Department of Vascular Surgery, Chinese PLA General Hospital, 100853, Beijing, China.
| | - Zhijin Xing
- Department of ultrasound medicine, Shenzhen Hospital of the University of Hong Kong, 518053, Shenzhen, China
| | - Hu Jin
- Division of Electrical Engineering, Hanyang University, 15588, Ansan, Republic of Korea
| | - Chun Zhao
- College of Information and Communication Engineering, Sungkyunkwan University, Chunchun-Dong, Changan-Ku, 440746, Suwon, Republic of Korea.
| |
Collapse
|
2
|
Khaligh SS, Khalid-Salako F, Kurt H, Yüce M. Exploring the Interaction of Biotinylated FcGamma RI and IgG1 Monoclonal Antibodies on Streptavidin-Coated Plasmonic Sensor Chips for Label-Free VEGF Detection. BIOSENSORS 2024; 14:634. [PMID: 39727899 DOI: 10.3390/bios14120634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2024] [Revised: 12/16/2024] [Accepted: 12/19/2024] [Indexed: 12/28/2024]
Abstract
Vascular endothelial growth factor (VEGF) is a critical angiogenesis biomarker associated with various pathological conditions, including cancer. This study leverages pre-biotinylated FcγRI interactions with IgG1-type monoclonal antibodies to develop a sensitive VEGF detection method. Utilizing surface plasmon resonance (SPR) technology, we characterized the binding dynamics of immobilized biotinylated FcγRI to an IgG1-type antibody, Bevacizumab (AVT), through kinetic studies and investigated suitable conditions for sensor surface regeneration. Subsequently, we characterized the binding of FcγRI-captured AVT to VEGF, calculating kinetic constants and binding affinity. A calibration curve was established to analyze the VEGF quantification capacity and accuracy of the biosensor, computing the limits of blank, detection, and quantification at a 95% confidence interval. Additionally, the specificity of the biosensor for VEGF over other protein analytes was assessed. This innovative biomimetic approach enabled FcγRI-mediated site-specific AVT capture, establishing a stable and reusable platform for detecting and accurately quantifying VEGF. The results indicate the effectiveness of the plasmonic sensor platform for VEGF detection, making it suitable for research applications and, potentially, clinical diagnostics. Utilizing FcγRI-IgG1 antibody binding, this study highlights the industrial and clinical value of advanced biosensing technologies, offering insights to enhance therapeutic monitoring and improve outcomes in anti-VEGF therapies.
Collapse
Affiliation(s)
- Soodeh Salimi Khaligh
- SUNUM Nanotechnology Research and Application Centre, Sabanci University, Istanbul 34956, Türkiye
| | - Fahd Khalid-Salako
- SUNUM Nanotechnology Research and Application Centre, Sabanci University, Istanbul 34956, Türkiye
| | - Hasan Kurt
- Department of Bioengineering, Royal School of Mines, Imperial College London, London SW7 2AZ, UK
| | - Meral Yüce
- SUNUM Nanotechnology Research and Application Centre, Sabanci University, Istanbul 34956, Türkiye
- Department of Bioengineering, Royal School of Mines, Imperial College London, London SW7 2AZ, UK
| |
Collapse
|
3
|
Tang C, Zhou K, Wu D, Zhu H. Nanoparticles as a Novel Platform for Cardiovascular Disease Diagnosis and Therapy. Int J Nanomedicine 2024; 19:8831-8846. [PMID: 39220195 PMCID: PMC11365508 DOI: 10.2147/ijn.s474888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Accepted: 08/18/2024] [Indexed: 09/04/2024] Open
Abstract
Cardiovascular disease (CVD) is a major global health issue with high mortality and morbidity rates. With the advances in nanotechnology, nanoparticles are receiving increasing attention in diagnosing and treating CVD. Previous studies have explored the use of nanoparticles in noninvasive diagnostic technologies, such as magnetic resonance imaging and computed tomography. Nanoparticles have been extensively studied as drug carriers and prognostic factors, demonstrating synergistic efficacy. This review summarized the current applications of nanoparticles in CVD and discussed their opportunities and challenges for further exploration.
Collapse
Affiliation(s)
- Chuanyun Tang
- The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, People’s Republic of China
| | - Kexun Zhou
- Department of Medical Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, People’s Republic of China
| | - Di Wu
- The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, People’s Republic of China
| | - Hong Zhu
- Department of Medical Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, People’s Republic of China
| |
Collapse
|
4
|
Chen SJ, Lu SY, Tseng CC, Huang KH, Chen TL, Fu LM. Rapid Microfluidic Immuno-Biosensor Detection System for the Point-of-Care Determination of High-Sensitivity Urinary C-Reactive Protein. BIOSENSORS 2024; 14:283. [PMID: 38920587 PMCID: PMC11201708 DOI: 10.3390/bios14060283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/20/2024] [Accepted: 05/28/2024] [Indexed: 06/27/2024]
Abstract
A microfluidic immuno-biosensor detection system consisting of a microfluidic spectrum chip and a micro-spectrometer detection device is presented for the rapid point-of-care (POC) detection and quantification of high-sensitivity C-reactive protein (hs-CRP) in urine. The detection process utilizes a highly specific enzyme-linked immunosorbent assay (ELISA) method, in which capture antibodies and detection antibodies are pre-deposited on the substrate of the microchip and used to form an immune complex with the target antigen. Horseradish peroxidase (HRP) is added as a marker enzyme, followed by a colorimetric reaction using 3,3',5,5'-tetramethylbenzidine (TMB). The absorbance values (a.u.) of the colorimetric reaction compounds are measured using a micro-spectrometer device and used to measure the corresponding hs-CRP concentration according to the pre-established calibration curve. It is shown that the hs-CRP concentration can be determined within 50 min. In addition, the system achieves recovery rates of 93.8-106.2% in blind water samples and 94.5-104.6% in artificial urine. The results showed that the CRP detection results of 41 urine samples from patients with chronic kidney disease (CKD) were highly consistent with the conventional homogeneous particle-enhanced turbidimetric immunoassay (PETIA) method's detection results (R2 = 0.9910). The experimental results showed its applicability in the detection of CRP in both urine and serum. Overall, the results indicate that the current microfluidic ELISA detection system provides an accurate and reliable method for monitoring the hs-CRP concentration in point-of-care applications.
Collapse
Affiliation(s)
- Szu-Jui Chen
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| | - Song-Yu Lu
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| | - Chin-Chung Tseng
- Division of Nephrology, Department of Internal Medicine, National Cheng Kung University Hospital, Tainan 70101, Taiwan;
- College of Medicine, National Cheng Kung University, Tainan 70101, Taiwan
| | - Kuan-Hsun Huang
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| | - To-Lin Chen
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| |
Collapse
|
5
|
Borg KN, Jaffiol R, Ho YP, Zeng S. Enhanced biosensing of tumor necrosis factor-alpha based on aptamer-functionalized surface plasmon resonance substrate and Goos-Hänchen shift. Analyst 2024; 149:3017-3025. [PMID: 38606503 DOI: 10.1039/d4an00194j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2024]
Abstract
Tumor necrosis factor-alpha (TNF-α) serves as a crucial biomarker in various diseases, necessitating sensitive detection methodologies. This study introduces an innovative approach utilizing an aptamer-functionalized surface plasmon resonance (SPR) substrate together with an ultrasensitive measure, the Goos-Hänchen (GH) shift, to achieve sensitive detection of TNF-α. The developed GH-aptasensing platform has shown a commendable figure-of-merit of 1.5 × 104 μm per RIU, showcasing a maximum detectable lateral position shift of 184.7 ± 1.2 μm, as characterized by the glycerol measurement. Employing aptamers as the recognition unit, the system exhibits remarkable biomolecule detection capabilities, including the experimentally obtained detection limit of 1 aM for the model protein bovine serum albumin (BSA), spanning wide dynamic ranges. Furthermore, the system successfully detects TNF-α, a small cytokine, with an experimental detection limit of 1 fM, comparable to conventional SPR immunoassays. This achievement represents one of the lowest experimentally derived detection limits for cytokines in aptamer-based SPR sensing. Additionally, the application of the GH shift marks a ground breaking advancement in aptamer-based biosensing, holding significant promise for pushing detection limits further, especially for small cytokine targets.
Collapse
Affiliation(s)
- Kathrine Nygaard Borg
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China.
- Light, Nanomaterials & Nanotechnologies (L2n), CNRS-UMR 7076, University of Technology of Troyes, 10000, Troyes, France.
| | - Rodolphe Jaffiol
- Light, Nanomaterials & Nanotechnologies (L2n), CNRS-UMR 7076, University of Technology of Troyes, 10000, Troyes, France.
| | - Yi-Ping Ho
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China.
- Centre for Biomaterials, The Chinese University of Hong Kong, Hong Kong SAR, China
- Hong Kong Branch of CAS Center for Excellence in Animal Evolution and Genetics, Hong Kong SAR, China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong SAR, China
| | - Shuwen Zeng
- Light, Nanomaterials & Nanotechnologies (L2n), CNRS-UMR 7076, University of Technology of Troyes, 10000, Troyes, France.
| |
Collapse
|
6
|
Dhar A, Gupta SL, Saini P, Sinha K, Khandelwal A, Tyagi R, Singh A, Sharma P, Jaiswal RK. Nanotechnology-based theranostic and prophylactic approaches against SARS-CoV-2. Immunol Res 2024; 72:14-33. [PMID: 37682455 DOI: 10.1007/s12026-023-09416-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 08/15/2023] [Indexed: 09/09/2023]
Abstract
SARS-CoV-2 (COVID-19) pandemic has been an unpredicted burden on global healthcare system by infecting over 700 million individuals, with approximately 6 million deaths worldwide. COVID-19 significantly impacted all sectors, but it very adversely affected the healthcare system. These effects were much more evident in the resource limited part of the world. Individuals with acute conditions were also severely impacted. Although classical COVID-19 diagnostics such as RT-PCR and rapid antibody testing have played a crucial role in reducing the spread of infection, these diagnostic techniques are associated with certain limitations. For instance, drawback of RT-PCR diagnostics is that due to degradation of viral RNA during shipping, it can give false negative results. Also, rapid antibody testing majorly depends on the phase of infection and cannot be performed on immune compromised individuals. These limitations in current diagnostic tools require the development of nanodiagnostic tools for early detection of COVID-19 infection. Therefore, the SARS-CoV-2 outbreak has necessitated the development of specific, responsive, accurate, rapid, low-cost, and simple-to-use diagnostic tools at point of care. In recent years, early detection has been a challenge for several health diseases that require prompt attention and treatment. Disease identification at an early stage, increased imaging of inner health issues, and ease of diagnostic processes have all been established using a new discipline of laboratory medicine called nanodiagnostics, even before symptoms have appeared. Nanodiagnostics refers to the application of nanoparticles (material with size equal to or less than 100 nm) for medical diagnostic purposes. The special property of nanomaterials compared to their macroscopic counterparts is a lesser signal loss and an enhanced electromagnetic field. Nanosize of the detection material also enhances its sensitivity and increases the signal to noise ratio. Microchips, nanorobots, biosensors, nanoidentification of single-celled structures, and microelectromechanical systems are some of the most modern nanodiagnostics technologies now in development. Here, we have highlighted the important roles of nanotechnology in healthcare sector, with a detailed focus on the management of the COVID-19 pandemic. We outline the different types of nanotechnology-based diagnostic devices for SARS-CoV-2 and the possible applications of nanomaterials in COVID-19 treatment. We also discuss the utility of nanomaterials in formulating preventive strategies against SARS-CoV-2 including their use in manufacture of protective equipment, formulation of vaccines, and strategies for directly hindering viral infection. We further discuss the factors hindering the large-scale accessibility of nanotechnology-based healthcare applications and suggestions for overcoming them.
Collapse
Affiliation(s)
- Atika Dhar
- National Institute of Immunology, New Delhi, India, 110067
| | | | - Pratima Saini
- National Institute of Immunology, New Delhi, India, 110067
| | - Kirti Sinha
- Department of Zoology, Patna Science College, Patna University, Patna, Bihar, India
| | | | - Rohit Tyagi
- College of Veterinary Medicine, Huazhong Agricultural University, Wuhan, 430070, China
| | - Alka Singh
- Department of Chemistry, Feroze Gandhi College, Raebareli, U.P, India, 229001
| | - Priyanka Sharma
- Department of Zoology, Patna Science College, Patna University, Patna, Bihar, India.
| | - Rishi Kumar Jaiswal
- Department of Cancer Biology, Cardinal Bernardin Cancer Center, Loyola University Chicago, Stritch School of Medicine, Maywood, IL, 60153, USA.
| |
Collapse
|
7
|
Zhu S, Jaffiol R, Crunteanu A, Vézy C, Chan ST, Yuan W, Ho HP, Zeng S. Label-free biosensing with singular-phase-enhanced lateral position shift based on atomically thin plasmonic nanomaterials. LIGHT, SCIENCE & APPLICATIONS 2024; 13:2. [PMID: 38161210 PMCID: PMC10757996 DOI: 10.1038/s41377-023-01345-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 11/18/2023] [Accepted: 11/24/2023] [Indexed: 01/03/2024]
Abstract
Rapid plasmonic biosensing has attracted wide attention in early disease diagnosis and molecular biology research. However, it was still challenging for conventional angle-interrogating plasmonic sensors to obtain higher sensitivity without secondary amplifying labels such as plasmonic nanoparticles. To address this issue, we developed a plasmonic biosensor based on the enhanced lateral position shift by phase singularity. Such singularity presents as a sudden phase retardation at the dark point of reflection from resonating plasmonic substrate, leading to a giant position shift on reflected beam. Herein, for the first time, the atomically thin layer of Ge2Sb2Te5 (GST) on silver nanofilm was demonstrated as a novel phase-response-enhancing plasmonic material. The GST layer was not only precisely engineered to singularize phase change but also served as a protective layer for active silver nanofilm. This new configuration has achieved a record-breaking largest position shift of 439.3 μm measured in calibration experiments with an ultra-high sensitivity of 1.72 × 108 nm RIU-1 (refractive index unit). The detection limit was determined to be 6.97 × 10-7 RIU with a 0.12 μm position resolution. Besides, a large figure of merit (FOM) of 4.54 × 1011 μm (RIU∙°)-1 was evaluated for such position shift interrogation, enabling the labelfree detection of trace amounts of biomolecules. In targeted biosensing experiments, the optimized sensor has successfully detected small cytokine biomarkers (TNF-α and IL-6) with the lowest concentration of 1 × 10-16 M. These two molecules are the key proinflammatory cancer markers in clinical diagnosis, which cannot be directly screened by current clinical techniques. To further validate the selectivity of our sensing systems, we also measured the affinity of integrin binding to arginylglycylaspartic acid (RGD) peptide (a key protein interaction in cell adhesion) with different Mn2+ ion concentrations, ranging from 1 nM to 1 mM.
Collapse
Affiliation(s)
- Shaodi Zhu
- Light, Nanomaterials & Nanotechnologies (L2n), CNRS-EMR 7004, University of Technology of Troyes, 10000, Troyes, France
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Rodolphe Jaffiol
- Light, Nanomaterials & Nanotechnologies (L2n), CNRS-EMR 7004, University of Technology of Troyes, 10000, Troyes, France
| | - Aurelian Crunteanu
- XLIM Research Institute, UMR 7252 CNRS/University of Limoges, 123, Avenue Albert Thomas, Limoges, France
| | - Cyrille Vézy
- Light, Nanomaterials & Nanotechnologies (L2n), CNRS-EMR 7004, University of Technology of Troyes, 10000, Troyes, France
| | - Sik-To Chan
- Light, Nanomaterials & Nanotechnologies (L2n), CNRS-EMR 7004, University of Technology of Troyes, 10000, Troyes, France
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Wu Yuan
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Ho-Pui Ho
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China.
| | - Shuwen Zeng
- Light, Nanomaterials & Nanotechnologies (L2n), CNRS-EMR 7004, University of Technology of Troyes, 10000, Troyes, France.
| |
Collapse
|
8
|
Han L, Xu W, Liu T, Zhang Y, Ma Y, Jin M, Xu C. Improved Differential Evolution Algorithm for Sensitivity Enhancement of Surface Plasmon Resonance Biosensor Based on Two-Dimensional Material for Detection of Waterborne Bacteria. BIOSENSORS 2023; 13:600. [PMID: 37366965 DOI: 10.3390/bios13060600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 05/29/2023] [Accepted: 05/29/2023] [Indexed: 06/28/2023]
Abstract
Due to the large number of waterborne bacteria presenting in drinking water, their rapid and accurate identification has become a global priority. The surface plasmon resonance (SPR) biosensor with prism (BK7)-silver(Ag)-MXene(Ti3T2Cx)-graphene- affinity-sensing medium is examined in this paper, in which the sensing medium includes pure water, vibrio cholera (V. cholera), and escherichia coli (E. coli). For the Ag-affinity-sensing medium, the maximum sensitivity is obtained by E. coli, followed by V. cholera, and the minimum is pure water. Based on the fixed-parameter scanning (FPS) method, the highest sensitivity is 246.2 °/RIU by the MXene and graphene with monolayer, and with E. coli sensing medium. Therefore, the algorithm of improved differential evolution (IDE) is obtained. By the IDE algorithm, after three iterations, the maximum fitness value (sensitivity) of the SPR biosensor achieves 246.6 °/RIU by using the structure of Ag (61 nm)-MXene (monolayer)-graphene (monolayer)-affinity (4 nm)-E. coli. Compared with the FPS and differential evolution (DE) algorithm, the highest sensitivity is more accurate and efficient, and with fewer iterations. The performance optimization of multilayer SPR biosensors provides an efficient platform.
Collapse
Affiliation(s)
- Lei Han
- College of Mechanical and Electrical Engineering, Inner Mongolia Agricultural University, Hohhot 010018, China
| | - Wentao Xu
- College of Mechanical and Electrical Engineering, Inner Mongolia Agricultural University, Hohhot 010018, China
| | - Tao Liu
- College of Mechanical and Electrical Engineering, Inner Mongolia Agricultural University, Hohhot 010018, China
| | - Yong Zhang
- College of Mechanical and Electrical Engineering, Inner Mongolia Agricultural University, Hohhot 010018, China
| | - Yanhua Ma
- College of Mechanical and Electrical Engineering, Inner Mongolia Agricultural University, Hohhot 010018, China
| | - Min Jin
- College of Mechanical and Electrical Engineering, Inner Mongolia Agricultural University, Hohhot 010018, China
| | - Chaoyu Xu
- School of Mechanical Engineering and Electronic Information, China University of Geosciences (Wuhan), Wuhan 430074, China
| |
Collapse
|
9
|
Yuan Z, Han M, Li D, Hao R, Guo X, Sang S, Zhang H, Ma X, Jin H, Xing Z, Zhao C. A cost-effective smartphone-based device for rapid C-reaction protein (CRP) detection using magnetoelastic immunosensor. LAB ON A CHIP 2023; 23:2048-2056. [PMID: 36916284 DOI: 10.1039/d2lc01065h] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
C-Reaction protein (CRP) is a marker of nonspecific immunity for vital signs and wound assessment, and it can be used to diagnose infections in clinical medicine. However, measuring CRP level currently requires hospital-based instruments, high-cost reagents, and a complex process, all of which have limited its full capabilities for self-detection, a growing trend in modern medicine. In this study, we developed a novel smartphone-based device using advanced methods of magnetoelastic immunosensing to mitigate these limitations. We combined a system-on-chip (SoC) hardware architecture with smartphone apps to realize the sampling of resonance frequency shift on magnetoelastic chips, which can determine the ultra-sensitivity to mass change caused by the binding of anti-CRP antibody and CRP. Through detecting a multi-group of samples, we found that the resonance frequency shift was linearly proportional to the CRP concentration in the range from 0.1 to 100 μg mL-1, with a sensitivity of 12.90 Hz μg-1 mL-1 and a detection limit of 2.349 × 10-4 μg mL-1. Meanwhile, compared with the large-scale instrument used in clinical settings, the performance of our device was stable and significantly more portable, rapid and cost-effective, offering excellent potential for modern home-based diagnosis.
Collapse
Affiliation(s)
- Zhongyun Yuan
- Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Information and Computer, Taiyuan University of Technology, Taiyuan, 030024, China.
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Mengshu Han
- Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Information and Computer, Taiyuan University of Technology, Taiyuan, 030024, China.
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Donghao Li
- Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Information and Computer, Taiyuan University of Technology, Taiyuan, 030024, China.
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Runfang Hao
- Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Information and Computer, Taiyuan University of Technology, Taiyuan, 030024, China.
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Xing Guo
- Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Information and Computer, Taiyuan University of Technology, Taiyuan, 030024, China.
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Shengbo Sang
- Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Information and Computer, Taiyuan University of Technology, Taiyuan, 030024, China.
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Hongpeng Zhang
- Department of Vascular Surgery, Chinese PLA General Hospital, 100853, Beijing, China
| | - Xingyi Ma
- School of Science, Harbin Institute of Technology, Shenzhen, Guangdong 518055, China
| | - Hu Jin
- Division of Electrical Engineering, Hanyang University, 15588 Ansan, Republic of Korea
| | - Zhijin Xing
- Department of Ultrasound Medicine, Shenzhen Hospital of the University of Hong Kong, 518053, Shenzhen, China
| | - Chun Zhao
- College of Information and Communication Engineering, Sungkyunkwan University, Chunchun-Dong, Changan-Ku, 440746 Suwon, Republic of Korea.
| |
Collapse
|
10
|
Amoresi RAC, Roza NAV, Mazon T. Applying CeO2 nanorods in flexible electrochemical immunosensor to detect C-reactive protein. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
|
11
|
Smith BR, Edelman ER. Nanomedicines for cardiovascular disease. NATURE CARDIOVASCULAR RESEARCH 2023; 2:351-367. [PMID: 39195953 DOI: 10.1038/s44161-023-00232-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 01/25/2023] [Indexed: 08/29/2024]
Abstract
The leading cause of death in the world, cardiovascular disease (CVD), remains a formidable condition for researchers, clinicians and patients alike. CVD comprises a broad collection of diseases spanning the heart, the vasculature and the blood that runs through and interconnects them. Limitations in CVD therapeutic and diagnostic landscapes have generated excitement for advances in nanomedicine, a field focused on improving patient outcomes through transformative therapies, imaging agents and ex vivo diagnostics. CVD nanomedicines are fundamentally shaped by their intended clinical application, including (1) cardiac or heart-related biomaterials, which can be functionally (for example, mechanically, immunologically, electrically) improved by incorporating nanomaterials; (2) the vasculature, involving systemically injected nanotherapeutics and imaging nanodiagnostics, nano-enabled biomaterials or tissue-nanoengineered solutions; and (3) improving the sensitivity and/or specificity of ex vivo diagnostic devices for patient samples. While immunotherapy has developed into a key pillar of oncology in the past dozen years, CVD immunotherapy and immunoimaging are recently emergent and likely to factor substantially in CVD management in the coming decade. The nanomaterials in CVD-related clinical trials and many promising preclinical strategies indicate that nanomedicine is on the cusp of greatly impacting patients with CVD. Here we review these recent advances, highlighting key clinical opportunities in the rapidly emerging field of CVD nanomedicine.
Collapse
Affiliation(s)
- Bryan Ronain Smith
- Department of Biomedical Engineering and Institute for Quantitative Health Science and Engineering (IQ), Michigan State University, East Lansing, MI, USA.
| | - Elazer R Edelman
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
- Cardiovascular Division, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
12
|
Zhou L, Kato F, Iijima M, Nonaka T, Kuroda S, Ogi H. Mass-Fabrication Scheme of Highly Sensitive Wireless Electrodeless MEMS QCM Biosensor with Antennas on Inner Walls of Microchannel. Anal Chem 2023; 95:5507-5513. [PMID: 36961992 DOI: 10.1021/acs.analchem.3c00139] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2023]
Abstract
Quartz-crystal-microbalance (QCM) biosensor is a typical label-free biosensor, and its sensitivity can be greatly improved by removing electrodes and wires that would be otherwise attached to the surfaces of the quartz resonator. The wireless-electrodeless QCM biosensor was then developed using a microelectro-mechanical systems (MEMS) process, although challenges remain in the sensitivity, the coupling efficiency, and the miniaturization (or mass production). In this study, we establish a MEMS process to obtain a large number of identical ultrasensitive and highly efficient sensor chips with dimensions of 6 mm square. The fundamental shear resonance frequency of the thinned AT-cut quartz resonator packaged in the microchannel exceeds 160 MHz, which is excited by antennas deposited on inner walls of the microchannel, significantly improving the electro-mechanical coupling efficiency in the wireless operation. The high sensitivity of the developed MEMS QCM biosensors is confirmed by the immunoglobulin G (IgG) detection using protein A and ZZ-tag displaying a bionanocapsule (ZZ-BNC), where we find that the ZZ-BNC can provide more effective binding sites and higher affinity to the target molecules, indicating a further enhancement in the sensitivity of the MEMS QCM biosensor. We then perform the label-free C-reactive protein (CRP) detection using the ZZ-BNC-functionalized MEMS QCM biosensor, which achieves a detection limit of 1 ng mL-1 or less even with direct detection.
Collapse
Affiliation(s)
- Lianjie Zhou
- Graduate School of Engineering, Osaka University, Yamadaoka 2-1, Suita, Osaka 565-0871, Japan
| | - Fumihito Kato
- Department of Mechanical Engineering, Nippon Institute of Technology, Gakuendai 4-1, Miyashiro-machi, Minamisaitama, Saitama 345-8501, Japan
| | - Masumi Iijima
- Department of Nutritional Science and Food Safety, Tokyo University of Agriculture, Sakuragaoka 1-1-1, Setagaya-ku, Tokyo 156-8502, Japan
| | - Tomoyuki Nonaka
- Samco Inc., Waraya-cho 36, Takeda, Fushimi-ku, Kyoto 612-8443, Japan
| | - Shun'ichi Kuroda
- SANKEN, Osaka University, Mihogaoka 8-1, Ibaraki, Osaka 567-0047, Japan
| | - Hirotsugu Ogi
- Graduate School of Engineering, Osaka University, Yamadaoka 2-1, Suita, Osaka 565-0871, Japan
| |
Collapse
|
13
|
Das S, Devireddy R, Gartia MR. Surface Plasmon Resonance (SPR) Sensor for Cancer Biomarker Detection. BIOSENSORS 2023; 13:396. [PMID: 36979608 PMCID: PMC10046379 DOI: 10.3390/bios13030396] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/12/2023] [Accepted: 03/15/2023] [Indexed: 06/18/2023]
Abstract
A biomarker is a physiological observable marker that acts as a stand-in and, in the best-case scenario, forecasts a clinically significant outcome. Diagnostic biomarkers are more convenient and cost-effective than directly measuring the ultimate clinical outcome. Cancer is among the most prominent global health problems and a major cause of morbidity and death globally. Therefore, cancer biomarker assays that are trustworthy, consistent, precise, and verified are desperately needed. Biomarker-based tumor detection holds a lot of promise for improving disease knowledge at the molecular scale and early detection and surveillance. In contrast to conventional approaches, surface plasmon resonance (SPR) allows for the quick and less invasive screening of a variety of circulating indicators, such as circulating tumor DNA (ctDNA), microRNA (miRNA), circulating tumor cells (CTCs), lipids, and proteins. With several advantages, the SPR technique is a particularly beneficial choice for the point-of-care identification of biomarkers. As a result, it enables the timely detection of tumor markers, which could be used to track cancer development and suppress the relapse of malignant tumors. This review emphasizes advancements in SPR biosensing technologies for cancer detection.
Collapse
|
14
|
Wei Y, Ren Z, Ran Z, Wang R, Liu CB, Shi C, Liu CL, Wang C, Zhang YH. All-fiber SPR microfluidic chip for GDF11 detection. BIOMEDICAL OPTICS EXPRESS 2022; 13:6659-6670. [PMID: 36589582 PMCID: PMC9774855 DOI: 10.1364/boe.477303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 11/10/2022] [Accepted: 11/20/2022] [Indexed: 06/17/2023]
Abstract
In order to perform microfluidic detection of cytokines with low concentration, such as growth differentiation factor 11 (GDF11), the most common method is to construct microfluidic channels and integrate them with SPR sensing units. In this paper, we proposed a novel all-fiber SPR microfluidic chip for GDF11 detection. The method was to construct the SPR sensing area on a designed D-shaped multimode fiber, which was nested inside a quartz tube to form a semi-cylindrical microfluidic channel. The surface of the SPR sensing area experienced sensitization and specifically modification to achieve the specific detection of GDF11. When the sensitivity of detection was 1.38 nm/lg(g/mL) and the limit of detection was 0.52 pg/mL, the sample consumption was only 0.4 µL for a single detection. The novel all-fiber SPR microfluidic detection chip has the advantages of flexible design, compact structure and low sample consumption, which is expected to be used in wearable biosensing devices for real-time online monitoring of trace cytokines in vivo.
Collapse
Affiliation(s)
- Yong Wei
- College of Electronic & Information Engineering, Chongqing Three Gorges University, Chongqing 404100, China
| | - Zhuo Ren
- College of Electronic & Information Engineering, Chongqing Three Gorges University, Chongqing 404100, China
| | - Ze Ran
- College of Electronic & Information Engineering, Chongqing Three Gorges University, Chongqing 404100, China
| | - Rui Wang
- College of Electronic & Information Engineering, Chongqing Three Gorges University, Chongqing 404100, China
| | - Chun-Biao Liu
- College of Electronic & Information Engineering, Chongqing Three Gorges University, Chongqing 404100, China
| | - Chen Shi
- College of Electronic & Information Engineering, Chongqing Three Gorges University, Chongqing 404100, China
| | - Chun-Lan Liu
- College of Electronic & Information Engineering, Chongqing Three Gorges University, Chongqing 404100, China
| | - Chen Wang
- Chongqing Key Laboratory of Development and Utilization of Genuine Medicinal Materials in Three Gorges Reservoir Area, Chongqing Three Gorges Medical College, Chongqing 404120, China
| | - Yong-Hui Zhang
- Chongqing Key Laboratory of Development and Utilization of Genuine Medicinal Materials in Three Gorges Reservoir Area, Chongqing Three Gorges Medical College, Chongqing 404120, China
| |
Collapse
|
15
|
Singh MM, Satija J. Enzyme-assisted metal nanoparticles etching based plasmonic ELISA: Progress and insights. Anal Biochem 2022; 654:114820. [PMID: 35850200 DOI: 10.1016/j.ab.2022.114820] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 07/07/2022] [Accepted: 07/12/2022] [Indexed: 11/24/2022]
Abstract
The unique size and shape tunable localized surface plasmon resonance (LSPR) properties of the noble metal nanoparticle have been extensively exploited to realize a variety of enzyme-based optical biosensors. Although approaches like metal film deposition, nanoparticle aggregation, and synthesis & growth of metal nanoparticles are quite useful, metal nanoparticle etching-based biosensors offer greater sensitivity, selectivity, and stability against various environmental factors which makes this strategy easy to use for field applications. This review discusses the current state-of-art of plasmonic nanoparticle etching-based enzyme-linked immunosorbent assay (ELISA) realized for visual detection of various analytes. The naked eye detection, i.e. without any optical readout device, is the additional advantage of this sensing approach that reduces the analysis cost significantly making it feasible under resource-constrained settings. This review paper provides deeper insights into biocatalytic etching mechanisms of various plasmonic nanoparticles resulting in vivid color change as a function of analyte concentration. Although nanoparticle etching-based ELISA has huge potential, steps need to be taken to realize a point-of-care (POC) nanodiagnostic before its translation to a commercial technique or product that can be achieved in near future by integrating it with microfluidics technology and other technological avenues.
Collapse
Affiliation(s)
| | - Jitendra Satija
- Centre for Nanobiotechnology, VIT, Vellore, Tamil Nadu, 632014, India.
| |
Collapse
|
16
|
Mobed A, Dolati S, Shakouri SK, Eftekharsadat B, Izadseresht B. Recent advances in biosensors for detection of osteoarthritis and rheumatoid arthritis biomarkers. SENSORS AND ACTUATORS A: PHYSICAL 2021; 331:112975. [DOI: 10.1016/j.sna.2021.112975] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/07/2023]
|
17
|
Thao NT, Hoang TX, Phan TB, Kim JY, Ta HKT, Trinh KTL, Tran NHT. Metal-enhanced sensing platform for the highly sensitive detection of C-reactive protein antibody and rhodamine B with applications in cardiovascular diseases and food safety. Dalton Trans 2021; 50:6962-6974. [PMID: 33929466 DOI: 10.1039/d0dt04353b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The potential applications of metal-enhanced fluorescence (MEF) devices include biosensors for the detection of trace amounts in biosciences, biotechnology, and pathogens that are relevant to medical diagnostics and food control. In the present study, the silver (Ag) film thickness (56 nm) of an MEF system was calibrated to maximize the depth-to-width ratio (Γ) of the surface plasmon resonance (SPR) active metal from reflectance dip curves. Upon plasmon coupling with thermally evaporated Ag, we demonstrated a 2.21-fold enhancement compared to the pristine flat substrate with the coefficient of variation (CV) ≈0.22% and the limit of detection (LOD) 0.001 mg L-1 of the concentration of an Alexa Fluor 488-labeled anti-C-reactive protein antibody (CRP@Alexa fluor 488). The structure was developed to simplify the in situ generation of biosensors for the surface-enhanced Raman spectroscopy (SERS) to determine Rhodamine B (RhB) with a highly robust performance. The procedure presented a simple and rapid sample pretreatment for the determination of RhB with a limit of quantification of 10-10 M and a satisfactory linear response (0.98). The results showed the excellent performance of the surface plasmon coupled emission (SPCE), which opens up possibilities for the accurate detection of small-volume and low-concentration target analytes due to the improved sensitivity and signal-to-noise ratio (SNR).
Collapse
Affiliation(s)
- Nguyen Thanh Thao
- Faculty of Materials Science and Technology, University of Science, Ho Chi Minh City, Viet Nam.
| | | | | | | | | | | | | |
Collapse
|
18
|
Letchumanan I, Arshad MKM, Gopinath SCB. Nanodiagnostic Attainments and Clinical Perspectives on C-Reactive Protein: Cardiovascular Disease Risks Assessment. Curr Med Chem 2021; 28:986-1002. [PMID: 31971105 DOI: 10.2174/0929867327666200123092648] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 10/12/2019] [Accepted: 10/18/2019] [Indexed: 01/08/2023]
Abstract
Cardiovascular disease (CVD) has become one of the leading causes of morbidity and mortality in both men and women. According to the World Health Organization (WHO), ischemic heart disease is the major issue due to the narrowing of the coronary artery by plaque formation on the artery wall, which causes an inadequate flow of oxygen and blood to the heart and is called 'coronary artery disease'. The CVD death rate increased by up to 15% in 2016 (~17.6 million) compared to the past decade. This tremendous increment urges the development of a suitable biomarker for rapid and early diagnosis. Currently, C-reactive protein (CRP) is considered an outstanding biomarker for quick and accurate outcomes in clinical analyses. Various techniques have also been used to diagnose CVD, including surface plasmon resonance (SPR), colorimetric assay, enzyme-linked immunosorbent assay (ELISA), fluoro-immunoassays, chemiluminescent assays, and electrical measurements. This review discusses such diagnostic strategies and how current, cutting-edge technologies have enabled the development of high-performance detection methodologies. Concluding remarks have been made concerning the clinical significance and the use of nanomaterial in medical diagnostics towards nanotheranostics.
Collapse
Affiliation(s)
- Iswary Letchumanan
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| | - M K Md Arshad
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| |
Collapse
|
19
|
Li M, Xia X, Meng S, Ma Y, Yang T, Yang Y, Hu R. An electrochemical immunosensor coupling a bamboo-like carbon nanostructure substrate with toluidine blue-functionalized Cu(ii)-MOFs as signal probes for a C-reactive protein assay. RSC Adv 2021; 11:6699-6708. [PMID: 35423224 PMCID: PMC8694918 DOI: 10.1039/d0ra09496j] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Accepted: 01/18/2021] [Indexed: 12/13/2022] Open
Abstract
In this paper, a novel sandwich immunosensor based on a toluidine blue (Tb) loaded metal organic framework (Cu(ii)-HKUST-1/Tb) as the signal element and a nitrogen-doped 3D carbon nanostructure as the electrode substrate was constructed for the detection of C-reactive protein (CRP). Tb as an electrochemically active agent usually forms a polymer by aggregation in the solvent, causing a poor electrochemical response. Therefore, in order to overcome this obstacle, Cu(ii)-HKUST-1 with a porous nanostructure and large specific surface area as a carrier could adsorb a large number of Tb molecules on its surface to improve its electrochemical performance. In addition, the high electron transfer efficiency of the N-doped bamboo-like carbon nanotubes (CoFe/N-GCT) improves the sensitivity of the biosensor. Differential pulse voltammetry (DPV) was used to detect the current signal of Tb at -0.2 V. The current response increased with the increase in concentration of CRP, ranging from 0.5 to 200 ng mL-1. The detection limit is 166.7 pg mL-1 (S/N = 3). Moreover, the proposed biosensor can be applied in real serum sample detection. It has potential applications in the field of biomedicine assays.
Collapse
Affiliation(s)
- Mei Li
- College of Chemistry and Chemical Engineering, Yunnan Normal University Kunming 650500 China +86 871 65941086
| | - Xiaojuan Xia
- College of Chemistry and Chemical Engineering, Yunnan Normal University Kunming 650500 China +86 871 65941086
| | - Shuang Meng
- College of Chemistry and Chemical Engineering, Yunnan Normal University Kunming 650500 China +86 871 65941086
| | - YuChan Ma
- College of Chemistry and Chemical Engineering, Yunnan Normal University Kunming 650500 China +86 871 65941086
| | - Tong Yang
- College of Chemistry and Chemical Engineering, Yunnan Normal University Kunming 650500 China +86 871 65941086
| | - Yunhui Yang
- College of Chemistry and Chemical Engineering, Yunnan Normal University Kunming 650500 China +86 871 65941086
| | - Rong Hu
- College of Chemistry and Chemical Engineering, Yunnan Normal University Kunming 650500 China +86 871 65941086
| |
Collapse
|
20
|
|
21
|
Surface Acoustic Wave Sensor for C-Reactive Protein Detection. SENSORS 2020; 20:s20226640. [PMID: 33228249 PMCID: PMC7699588 DOI: 10.3390/s20226640] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/17/2020] [Accepted: 11/18/2020] [Indexed: 12/21/2022]
Abstract
A surface acoustic wave (SAW) sensor was investigated for its application in C-reactive protein (CRP) detection. Piezoelectric lithium niobate (LiNbO3) substrates were used to study their frequency response characteristics in a SAW sensor with a CRP sensing area. After the fabrication of the SAW sensor, the immobilization process was performed for CRP/anti-CRP interaction. The CRP/anti-CRP interaction can be detected as mass variations in the sensing area. These mass variations may produce changes in the amplitude of sensor response. It was clearly observed that a CRP concentration of 0.1 μg/mL can be detected in the proposed SAW sensor. A good fitting linear relationship between the detected insertion loss (amplitude) and the concentrations of CRP from 0.1 μg/mL to 1 mg/mL was obtained. The detected shifts in the amplitude of insertion loss in SAW sensors for different CRP concentrations may be useful in the diagnosis of risk of cardiovascular diseases.
Collapse
|
22
|
Imas JJ, Ruiz Zamarreño C, Zubiate P, Sanchez-Martín L, Campión J, Matías IR. Optical Biosensors for the Detection of Rheumatoid Arthritis (RA) Biomarkers: A Comprehensive Review. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6289. [PMID: 33158306 PMCID: PMC7663853 DOI: 10.3390/s20216289] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 10/23/2020] [Accepted: 10/29/2020] [Indexed: 12/13/2022]
Abstract
A comprehensive review of optical biosensors for the detection of biomarkers associated with rheumatoid arthritis (RA) is presented here, including microRNAs (miRNAs), C-reactive protein (CRP), rheumatoid factor (RF), anti-citrullinated protein antibodies (ACPA), interleukin-6 (IL-6) and histidine, which are biomarkers that enable RA detection and/or monitoring. An overview of the different optical biosensors (based on fluorescence, plasmon resonances, interferometry, surface-enhanced Raman spectroscopy (SERS) among other optical techniques) used to detect these biomarkers is given, describing their performance and main characteristics (limit of detection (LOD) and dynamic range), as well as the connection between the respective biomarker and rheumatoid arthritis. It has been observed that the relationship between the corresponding biomarker and rheumatoid arthritis tends to be obviated most of the time when explaining the mechanism of the optical biosensor, which forces the researcher to look for further information about the biomarker. This review work attempts to establish a clear association between optical sensors and rheumatoid arthritis biomarkers as well as to be an easy-to-use tool for the researchers working in this field.
Collapse
Affiliation(s)
- José Javier Imas
- Electrical, Electronics and Communications Engineering Department, Public University of Navarra, 31006 Pamplona, Spain; (J.J.I.); (P.Z.); (I.R.M.)
- Institute of Smart Cities (ISC), Public University of Navarra, 31006 Pamplona, Spain
| | - Carlos Ruiz Zamarreño
- Electrical, Electronics and Communications Engineering Department, Public University of Navarra, 31006 Pamplona, Spain; (J.J.I.); (P.Z.); (I.R.M.)
- Institute of Smart Cities (ISC), Public University of Navarra, 31006 Pamplona, Spain
| | - Pablo Zubiate
- Electrical, Electronics and Communications Engineering Department, Public University of Navarra, 31006 Pamplona, Spain; (J.J.I.); (P.Z.); (I.R.M.)
| | | | - Javier Campión
- Making Genetics S.L., Plaza CEIN 5, 31110 Noáin, Spain; (L.S.-M.); (J.C.)
| | - Ignacio Raúl Matías
- Electrical, Electronics and Communications Engineering Department, Public University of Navarra, 31006 Pamplona, Spain; (J.J.I.); (P.Z.); (I.R.M.)
- Institute of Smart Cities (ISC), Public University of Navarra, 31006 Pamplona, Spain
| |
Collapse
|
23
|
Choi JH, Lee JH, Son J, Choi JW. Noble Metal-Assisted Surface Plasmon Resonance Immunosensors. SENSORS 2020; 20:s20041003. [PMID: 32069896 PMCID: PMC7071002 DOI: 10.3390/s20041003] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 02/05/2020] [Accepted: 02/11/2020] [Indexed: 02/06/2023]
Abstract
For the early diagnosis of several diseases, various biomarkers have been discovered and utilized through the measurement of concentrations in body fluids such as blood, urine, and saliva. The most representative analytical method for biomarker detection is an immunosensor, which exploits the specific antigen-antibody immunoreaction. Among diverse analytical methods, surface plasmon resonance (SPR)-based immunosensors are emerging as a potential detection platform due to high sensitivity, selectivity, and intuitive features. Particularly, SPR-based immunosensors could detect biomarkers without labeling of a specific detection probe, as typical immunosensors such as enzyme-linked immunosorbent assay (ELISA) use enzymes like horseradish peroxidase (HRP). In this review, SPR-based immunosensors utilizing noble metals such as Au and Ag as SPR-inducing factors for the measurement of different types of protein biomarkers, including viruses, microbes, and extracellular vesicles (EV), are briefly introduced.
Collapse
Affiliation(s)
- Jin-Ha Choi
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Korea; (J.-H.C.); (J.S.)
| | - Jin-Ho Lee
- School of Biomedical Convergence Engineering, Pusan National University, Yangsan 50612, Korea;
| | - Joohyung Son
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Korea; (J.-H.C.); (J.S.)
| | - Jeong-Woo Choi
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Korea; (J.-H.C.); (J.S.)
- Department of Biomedical Engineering, Sogang University, Seoul 04107, Korea
- Correspondence: ; Tel.: +(82)-2-705-8480; Fax: +(82)-2-718-1976
| |
Collapse
|
24
|
Ma Y, Yang J, Yang T, Deng Y, Gu M, Wang M, Hu R, Yang Y. Electrochemical detection of C-reactive protein using functionalized iridium nanoparticles/graphene oxide as a tag. RSC Adv 2020; 10:9723-9729. [PMID: 35497247 PMCID: PMC9050126 DOI: 10.1039/c9ra10386d] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Accepted: 02/20/2020] [Indexed: 11/21/2022] Open
Abstract
C-reactive protein (CRP) has become a recognized indicator of inflammation. CRP concentration in serum is an important indicator for monitoring early heart damage, and it is also a newly discovered coronary heart disease-associated inflammatory factor. A conductive nano-hybrid material composed of Au NPs and ionic liquid functionalized molybdenum disulfide (Au NPs/IL-MoS2) was prepared and utilized to immobilize primary CRP antibodies. Subsequently, 1,5-diaminonaphthalene (DN) was adsorbed onto graphene oxide (GO) through π–π stacking, which was used to load iridium nanoparticles (Ir NPs) as a tag to label secondary CRP antibodies. The large surface area of Au NPs/IL-MoS2 and the excellent electrocatalytic properties of Ir NPs/GO-DN toward the reduction of H2O2 resulted in a highly sensitive assay for CRP antigens. This immunosensor exhibited wide linear ranges from 0.01 to 100 ng mL−1 and a lower detection of limit of 3.3 pg mL−1 (S/N = 3). This CRP immunosensor can be applied in real serum sample analysis with satisfactory results, indicating that the immunosensor has potential applications in biomedical detection. Ir NPs@GO-DN was used as a tag to label CRP antibody to construct a sandwich CRP immunosensor.![]()
Collapse
Affiliation(s)
- Yuchan Ma
- College of Chemistry and Chemical Engineering
- Yunnan Normal University
- Kunming
- P. R. China
| | - Jiao Yang
- College of Chemistry and Chemical Engineering
- Yunnan Normal University
- Kunming
- P. R. China
| | - Tong Yang
- College of Chemistry and Chemical Engineering
- Yunnan Normal University
- Kunming
- P. R. China
| | - Yan Deng
- College of Chemistry and Chemical Engineering
- Yunnan Normal University
- Kunming
- P. R. China
| | - Mengqiao Gu
- College of Chemistry and Chemical Engineering
- Yunnan Normal University
- Kunming
- P. R. China
| | - Min Wang
- College of Chemistry and Chemical Engineering
- Yunnan Normal University
- Kunming
- P. R. China
| | - Rong Hu
- College of Chemistry and Chemical Engineering
- Yunnan Normal University
- Kunming
- P. R. China
| | - Yunhui Yang
- College of Chemistry and Chemical Engineering
- Yunnan Normal University
- Kunming
- P. R. China
| |
Collapse
|
25
|
Phosphorylcholine-based hydrogel for immobilization of biomolecules. Application to fluorometric microarrays for use in hybridization assays and immunoassays, and nanophotonic biosensing. Mikrochim Acta 2019; 186:570. [DOI: 10.1007/s00604-019-3691-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 07/07/2019] [Indexed: 12/11/2022]
|
26
|
Nishiyama K, Kasama T, Nakamata S, Ishikawa K, Onoshima D, Yukawa H, Maeki M, Ishida A, Tani H, Baba Y, Tokeshi M. Ultrasensitive detection of disease biomarkers using an immuno-wall device with enzymatic amplification. Analyst 2019; 144:4589-4595. [PMID: 31237262 DOI: 10.1039/c9an00480g] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
We present an ultrasensitive immunoassay system for disease biomarkers utilizing the immuno-wall device and an enzymatic amplification reaction. The immuno-wall device consisted of 40 microchannels, each of which contained an antibody-modified wall-like structure along the longitudinal axis of the microchannel. The wall was fabricated with a water-soluble photopolymer containing streptavidin by photolithography, and biotinylated capture antibodies were immobilized on the sides through streptavidin-biotin interaction. For an assay, introducing the target biomarker and secondary and labeled antibodies produced a sandwich complex anchored on the sides of the wall. A conventional immuno-wall device uses a fluorescence-labeled antibody as a labeling antibody. To achieve an ultrasensitive detection of a trace biomarker, we used an enzyme label and amplified the signal with the enzymatic reaction with a fluorogenic substrate in the microchannel. The highest signal/background ratio was obtained by using alkaline phosphatase-labeled antibody and 9H-(1,3-dichloro-9,9-dimethylacridin-2-one-7-yl) phosphate. To evaluate the device performance, we detected human C-reactive protein (CRP) as a model biomarker. The detection limit (LOD) of CRP in phosphate-buffered saline was 2.5 pg mL-1 with a sample volume of 0.25 μL. This LOD was approximately 3 orders of magnitude lower than that obtained with fluorescent-dye (DyLight 650)-labeled antibody. In addition, the present device provided a wide detection range of 0.0025-10 ng mL-1 for CRP. We successfully developed an ultrasensitive immunoassay system with simple operation and only a small sample volume.
Collapse
Affiliation(s)
- Keine Nishiyama
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan
| | - Toshihiro Kasama
- Department of Bioengineering, School of Engineering, The University of Tokyo, Shinkawasaki, Saiwai-ku, Kawasaki-shi, Kanagawa, 212-0032, Japan and ImPACT Research Center for Advanced Nanobiodevices, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
| | - Seiya Nakamata
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan
| | - Koya Ishikawa
- Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
| | - Daisuke Onoshima
- ImPACT Research Center for Advanced Nanobiodevices, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan and Institute of Nano-Life-Systems, Institutes of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
| | - Hiroshi Yukawa
- ImPACT Research Center for Advanced Nanobiodevices, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan and Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan and Institute of Nano-Life-Systems, Institutes of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
| | - Masatoshi Maeki
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.
| | - Akihiko Ishida
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.
| | - Hirofumi Tani
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.
| | - Yoshinobu Baba
- ImPACT Research Center for Advanced Nanobiodevices, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan and Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan and Institute of Nano-Life-Systems, Institutes of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
| | - Manabu Tokeshi
- ImPACT Research Center for Advanced Nanobiodevices, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan and Institute of Nano-Life-Systems, Institutes of Innovation for Future Society, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan and Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan. and Innovative Research Centre for Preventive Medical Engineering, Nagoya University, Furo-cho Chikusa-ku, Nagoya 464-8603, Japan
| |
Collapse
|
27
|
Mauriz E, Dey P, Lechuga LM. Advances in nanoplasmonic biosensors for clinical applications. Analyst 2019; 144:7105-7129. [DOI: 10.1039/c9an00701f] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Plasmonic biosensors can be conveniently used as portable diagnostic devices for attaining timely and cost-effective clinical outcomes. Nanoplasmonics technology opens the way for sensor miniaturization, multiplexing and point of care testing.
Collapse
Affiliation(s)
- Elba Mauriz
- Department of Nursing and Physiotherapy
- Universidad de León
- 24071 León
- Spain
| | - Priyanka Dey
- Nanobiosensors and Bioanalytical Applications Group
- Catalan Institute of Nanoscience and Nanotechnology (ICN2)
- CSIC
- BIST
- and CIBER-BBN
| | - Laura M. Lechuga
- Nanobiosensors and Bioanalytical Applications Group
- Catalan Institute of Nanoscience and Nanotechnology (ICN2)
- CSIC
- BIST
- and CIBER-BBN
| |
Collapse
|
28
|
Barbosa AI, Reis NM. A critical insight into the development pipeline of microfluidic immunoassay devices for the sensitive quantitation of protein biomarkers at the point of care. Analyst 2018; 142:858-882. [PMID: 28217778 DOI: 10.1039/c6an02445a] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
The latest clinical procedures for the timely and cost-effective diagnosis of chronic and acute clinical conditions, such as cardiovascular diseases, cancer, chronic respiratory diseases, diabetes or sepsis (i.e. the biggest causes of death worldwide), involve the quantitation of specific protein biomarkers released into the blood stream or other physiological fluids (e.g. urine or saliva). The clinical thresholds are usually in the femtomolar to picolomar range, and consequently the measurement of these protein biomarkers heavily relies on highly sophisticated, bulky and automated equipment in centralised pathology laboratories. The first microfluidic devices capable of measuring protein biomarkers in miniaturised immunoassays were presented nearly two decades ago and promised to revolutionise point-of-care (POC) testing by offering unmatched sensitivity and automation in a compact POC format; however, the development and adoption of microfluidic protein biomarker tests has fallen behind expectations. This review presents a detailed critical overview into the pipeline of microfluidic devices developed in the period 2005-2016 capable of measuring protein biomarkers from the pM to fM range in formats compatible with POC testing, with a particular focus on the use of affordable microfluidic materials and compact low-cost signal interrogation. The integration of these two important features (essential unique selling points for the successful microfluidic diagnostic products) has been missed in previous review articles and explain the poor adoption of microfluidic technologies in this field. Most current miniaturised devices compromise either on the affordability, compactness and/or performance of the test, making current tests unsuitable for the POC measurement of protein biomarkers. Seven core technical areas, including (i) the selected strategy for antibody immobilisation, (ii) the surface area and surface-area-to-volume ratio, (iii) surface passivation, (iv) the biological matrix interference, (v) fluid control, (vi) the signal detection modes and (vii) the affordability of the manufacturing process and detection system, were identified as the key to the effective development of a sensitive and affordable microfluidic protein biomarker POC test.
Collapse
Affiliation(s)
- Ana I Barbosa
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK
| | - Nuno M Reis
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK and Department of Chemical Engineering, University of Bath, Claverton Down, Bath, BA2 7AY, UK.
| |
Collapse
|
29
|
Wang S, Luo J, He Y, Chai Y, Yuan R, Yang X. Combining Porous Magnetic Ni@C Nanospheres and CaCO 3 Microcapsule as Surface-Enhanced Raman Spectroscopy Sensing Platform for Hypersensitive C-Reactive Protein Detection. ACS APPLIED MATERIALS & INTERFACES 2018; 10:33707-33712. [PMID: 30182714 DOI: 10.1021/acsami.8b13061] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
In this work, we have designed an efficient and rapid surface-enhanced Raman spectroscopy (SERS) immunosensor for a supersensitive analysis of hypersensitive C-reactive protein (hs-CRP) with a label-free method by combining porous magnetic Ni@C nanospheres to aggregate together for simplifying the experiment operation and CaCO3 microcapsule to encapsulate rhodamine B as the Raman signal. The final solution containing the signal molecule was dropped on the Ag nanoparticle substrate, and the signal could be enhanced by Ag particles. First, rhodamine B was encapsulated in the CaCO3 microcapsule when it precipitated to form microcubes. Subsequently, the porous CaCO3 microcapsule was assembled layer by layer with poly(ether imide) (PEI) and a second antibody to obtain rhodamine B@CaCO3@PEI@Ab2. Then, the functionalized magnetic Ni@C nanospheres were prepared to immobilize the primary antibody (Ab1). Finally, the immunosensor was fabricated by the sandwiched antibody-antigen interactions. Compared to the DNA hydrogel, the low-cost CaCO3 microcapsule would be rapidly dissolved by ethylene diamine tetraacetic acid, releasing rhodamine B to produce a strong Raman signal for a rapid and efficient detection of hs-CRP. With the hs-CRP concentration ranging from 0.1 pg mL-1 to 1 μg mL-1, the SERS intensity of the platform has a linear relationship with the logarithm of hs-CRP concentration, and the detection limit was 0.01 pg mL-1. By this smart design, this work can give a direction for a rapid label-free SERS analysis.
Collapse
Affiliation(s)
- Shufan Wang
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemistry and Chemical Engineering , Southwest University , Chongqing 400715 , People's Republic of China
| | - Jiajia Luo
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemistry and Chemical Engineering , Southwest University , Chongqing 400715 , People's Republic of China
| | - Yi He
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemistry and Chemical Engineering , Southwest University , Chongqing 400715 , People's Republic of China
| | - Yaqin Chai
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemistry and Chemical Engineering , Southwest University , Chongqing 400715 , People's Republic of China
| | - Ruo Yuan
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemistry and Chemical Engineering , Southwest University , Chongqing 400715 , People's Republic of China
| | - Xia Yang
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemistry and Chemical Engineering , Southwest University , Chongqing 400715 , People's Republic of China
| |
Collapse
|
30
|
António M, Nogueira J, Vitorino R, Daniel-da-Silva AL. Functionalized Gold Nanoparticles for the Detection of C-Reactive Protein. NANOMATERIALS 2018; 8:nano8040200. [PMID: 29597295 PMCID: PMC5923530 DOI: 10.3390/nano8040200] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Revised: 03/21/2018] [Accepted: 03/26/2018] [Indexed: 02/07/2023]
Abstract
C-reactive protein (CRP) is a very important biomarker of infection and inflammation for a number of diseases. Routine CRP measurements with high sensitivity and reliability are highly relevant to the assessment of states of inflammation and the efficacy of treatment intervention, and require the development of very sensitive, selective, fast, robust and reproducible assays. Gold nanoparticles (Au NPs) are distinguished for their unique electrical and optical properties and the ability to conjugate with biomolecules. Au NP-based probes have attracted considerable attention in the last decade in the analysis of biological samples due to their simplicity, high sensitivity and selectivity. Thus, this article aims to be a critical and constructive analysis of the literature of the last three years regarding the advances made in the development of bioanalytical assays based on gold nanoparticles for the in vitro detection and quantification of C-reactive protein from biological samples. Current methods for Au NP synthesis and the strategies for surface modification aiming at selectivity towards CRP are highlighted.
Collapse
Affiliation(s)
- Maria António
- CICECO-Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193 Aveiro, Portugal.
| | - João Nogueira
- CICECO-Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193 Aveiro, Portugal.
| | - Rui Vitorino
- iBiMED-Institute of Biomedicine, Department of Medical Sciences, University of Aveiro, 3810-193 Aveiro, Portugal.
| | - Ana L Daniel-da-Silva
- CICECO-Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193 Aveiro, Portugal.
| |
Collapse
|
31
|
Ferhan AR, Jackman JA, Park JH, Cho NJ, Kim DH. Nanoplasmonic sensors for detecting circulating cancer biomarkers. Adv Drug Deliv Rev 2018; 125:48-77. [PMID: 29247763 DOI: 10.1016/j.addr.2017.12.004] [Citation(s) in RCA: 69] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 09/29/2017] [Accepted: 12/08/2017] [Indexed: 12/20/2022]
Abstract
The detection of cancer biomarkers represents an important aspect of cancer diagnosis and prognosis. Recently, the concept of liquid biopsy has been introduced whereby diagnosis and prognosis are performed by means of analyzing biological fluids obtained from patients to detect and quantify circulating cancer biomarkers. Unlike conventional biopsy whereby primary tumor cells are analyzed, liquid biopsy enables the detection of a wide variety of circulating cancer biomarkers, including microRNA (miRNA), circulating tumor DNA (ctDNA), proteins, exosomes and circulating tumor cells (CTCs). Among the various techniques that have been developed to detect circulating cancer biomarkers, nanoplasmonic sensors represent a promising measurement approach due to high sensitivity and specificity as well as ease of instrumentation and operation. In this review, we discuss the relevance and applicability of three different categories of nanoplasmonic sensing techniques, namely surface plasmon resonance (SPR), localized surface plasmon resonance (LSPR) and surface-enhanced Raman scattering (SERS), for the detection of different classes of circulating cancer biomarkers.
Collapse
Affiliation(s)
- Abdul Rahim Ferhan
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Joshua A Jackman
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Jae Hyeon Park
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore
| | - Nam-Joon Cho
- School of Materials Science and Engineering, Nanyang Technological University, Singapore, 639798, Singapore.
| | - Dong-Hwan Kim
- School of Chemical Engineering, Sungkyunkwan University, 16419, Republic of Korea.
| |
Collapse
|
32
|
Booth MA, Gowers SAN, Leong CL, Rogers ML, Samper IC, Wickham AP, Boutelle MG. Chemical Monitoring in Clinical Settings: Recent Developments toward Real-Time Chemical Monitoring of Patients. Anal Chem 2017; 90:2-18. [PMID: 29083872 DOI: 10.1021/acs.analchem.7b04224] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Marsilea A Booth
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Sally A N Gowers
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Chi Leng Leong
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Michelle L Rogers
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Isabelle C Samper
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Aidan P Wickham
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| | - Martyn G Boutelle
- Department of Bioengineering, Imperial College London , London, SW7 2AZ, United Kingdom
| |
Collapse
|
33
|
Rational Design of Peptide-Functionalized Surface Plasmon Resonance Sensor for Specific Detection of TNT Explosive. SENSORS 2017; 17:s17102249. [PMID: 28973962 PMCID: PMC5676640 DOI: 10.3390/s17102249] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Revised: 09/25/2017] [Accepted: 09/28/2017] [Indexed: 12/14/2022]
Abstract
In this study, a rationally-designed 2,4,6-trinitrotoluene (TNT) binding peptide derived from an amino acid sequence of the complementarity-determining region (CDR) of an anti-TNT monoclonal antibody was used for TNT detection based on a maleimide-functionalized surface plasmon resonance (SPR) sensor. By antigen-docking simulation and screening, the TNT binding candidate peptides were obtained as TNTHCDR1 derived from the heavy chain of CDR1, TNTHCDR2 derived from CDR2, and TNTHCDR3 from CDR3 of an anti-TNT antibody. The binding events between candidate peptides and TNT were evaluated using the SPR sensor by direct determination based on the 3-aminopropyltriethoxysilane (APTES) surface. The TNT binding peptide was directly immobilized on the maleimide-functionalized sensor chip surface from N-γ-maleimidobutyryl-oxysuccinimide ester (GMBS). The results demonstrated that peptide TNTHCDR3 was identified and selected as a TNT binding peptide among the other two candidate peptides. Five kinds of TNT analogues were also investigated to testify the selectivity of TNT binding peptide TNTHCDR3. Furthermore, the results indicated that the APTES-GMBS-based SPR sensor chip procedure featured a great potential application for the direct detection of TNT.
Collapse
|
34
|
Psarouli A, Botsialas A, Salapatas A, Stefanitsis G, Nikita D, Jobst G, Chaniotakis N, Goustouridis D, Makarona E, Petrou PS, Raptis I, Misiakos K, Kakabakos SE. Fast label-free detection of C-reactive protein using broad-band Mach-Zehnder interferometers integrated on silicon chips. Talanta 2017; 165:458-465. [DOI: 10.1016/j.talanta.2017.01.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 12/30/2016] [Accepted: 01/02/2017] [Indexed: 11/28/2022]
|
35
|
Abstract
The design and application of sensors for monitoring biomolecules in clinical samples is a common goal of the sensing research community. Surface plasmon resonance (SPR) and other plasmonic techniques such as localized surface plasmon resonance (LSPR) and imaging SPR are reaching a maturity level sufficient for their application in monitoring biomolecules in clinical samples. In recent years, the first examples for monitoring antibodies, proteins, enzymes, drugs, small molecules, peptides, and nucleic acids in biofluids collected from patients afflicted with a series of medical conditions (Alzheimer's, hepatitis, diabetes, leukemia, and cancers such as prostate and breast cancers, among others) demonstrate the progress of SPR sensing in clinical chemistry. This Perspective reviews the current status of the field, showcasing a series of early successes in the application of SPR for clinical analysis and detailing a series of considerations regarding sensing schemes, exposing issues with analysis in biofluids, and comparing SPR with ELISA, while providing an outlook of the challenges currently associated with plasmonic materials, instrumentation, microfluidics, bioreceptor selection, selection of a clinical market, and validation of a clinical assay for applying SPR sensors to clinical samples. Research opportunities are proposed to further advance the field and transition SPR biosensors from research proof-of-concept stage to actual clinical applications.
Collapse
Affiliation(s)
- Jean-Francois Masson
- Département
de chimie, Université de Montréal, C.P. 6128 Succ. Centre-Ville, Montreal, Quebec H3C 3J7, Canada
- Centre
for self-assembled chemical structures (CSACS), McGill University, 801
Sherbrooke Street West, Montreal, Quebec H3A 2K6, Canada
| |
Collapse
|
36
|
Zhang Z, Xie J, Yu J, Lu Z, Liu Y. A novel colorimetric immunoassay strategy using iron(iii) oxide magnetic nanoparticles as a label for signal generation and amplification. J Mater Chem B 2017; 5:1454-1460. [DOI: 10.1039/c6tb02696f] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
A novel colorimetric immunoassay strategy has been developed using an iron oxide magnetic nanoparticle as a label for both signal generation and amplification.
Collapse
Affiliation(s)
- Zeying Zhang
- Institute for Clean Energy & Advanced Materials
- Faculty of Materials & Energy
- Southwest University
- Chongqing 400715
- China
| | - Jin Xie
- Institute for Clean Energy & Advanced Materials
- Faculty of Materials & Energy
- Southwest University
- Chongqing 400715
- China
| | - Jie Yu
- Institute for Clean Energy & Advanced Materials
- Faculty of Materials & Energy
- Southwest University
- Chongqing 400715
- China
| | - Zhisong Lu
- Institute for Clean Energy & Advanced Materials
- Faculty of Materials & Energy
- Southwest University
- Chongqing 400715
- China
| | - Yingshuai Liu
- Institute for Clean Energy & Advanced Materials
- Faculty of Materials & Energy
- Southwest University
- Chongqing 400715
- China
| |
Collapse
|
37
|
Goda T, Toya M, Matsumoto A, Miyahara Y. Poly(3,4-ethylenedioxythiophene) Bearing Phosphorylcholine Groups for Metal-Free, Antibody-Free, and Low-Impedance Biosensors Specific for C-Reactive Protein. ACS APPLIED MATERIALS & INTERFACES 2015; 7:27440-27448. [PMID: 26588324 DOI: 10.1021/acsami.5b09325] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Conducting polymers possessing biorecognition elements are essential for developing electrical biosensors sensitive and specific to clinically relevant biomolecules. We developed a new 3,4-ethylenedioxythiophene (EDOT) derivative bearing a zwitterionic phosphorylcholine group via a facile synthesis through the Michael-type addition thiol-ene "click" reaction for the detection of an acute-phase biomarker human C-reactive protein (CRP). The phosphorylcholine group, a major headgroup in phospholipid, which is the main constituent of plasma membrane, was also expected to resist nonspecific adsorption of other proteins at the electrode/solution interface. The biomimetic EDOT derivative was randomly copolymerized with EDOT, via an electropolymerization technique with a dopant sodium perchlorate, onto a glassy carbon electrode to make the synthesized polymer film both conductive and target-responsive. The conducting copolymer films were characterized by cyclic voltammetry, scanning electron microscopy, attenuated total reflection Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and electrochemical impedance spectroscopy. The specific interaction of CRP with phosphorylcholine in a calcium-containing buffer solution was determined by differential pulse voltammetry, which measures the altered redox reaction between the indicators ferricyanide/ferrocyanide as a result of the binding event. The conducting polymer-based protein sensor achieved a limit of detection of 37 nM with a dynamic range of 10-160 nM, covering the dynamically changing CRP levels in circulation during the acute phase. The results will enable the development of metal-free, antibody-free, and low-impedance electrochemical biosensors for the screening of nonspecific biomarkers of inflammation and infection.
Collapse
Affiliation(s)
- Tatsuro Goda
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University , 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062, Japan
| | - Masahiro Toya
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University , 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062, Japan
| | - Akira Matsumoto
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University , 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062, Japan
| | - Yuji Miyahara
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University , 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062, Japan
| |
Collapse
|