1
|
Plekhanova YV, Rai M, Reshetilov AN. Nanomaterials in bioelectrochemical devices: on applications enhancing their positive effect. 3 Biotech 2022; 12:231. [PMID: 35996672 PMCID: PMC9391563 DOI: 10.1007/s13205-022-03260-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 07/17/2022] [Indexed: 11/01/2022] Open
Abstract
Electrochemical biosensors and biofuel cells are finding an ever-increasing practical application due to several advantages. Biosensors are miniature measuring devices, which can be used for on-the-spot analyses, with small assay times and sample volumes. Biofuel cells have dual benefits of environmental cleanup and electric energy generation. Application of nanomaterials in biosensor and biofuel-cell devices increases their functioning efficiency and expands spheres of use. This review discusses the potential of nanomaterials in improving the basic parameters of bioelectrochemical systems, including the sensitivity increase, detection lower-limit decrease, detection-range change, lifetime increase, substrate-specificity control. In most cases, the consideration of the role of nanomaterials links a certain type of nanomaterial with its effect on the bioelectrochemical device upon the whole. The review aims at assessing the effects of nanomaterials on particular analytical parameters of a biosensor/biofuel-cell bioelectrochemical device.
Collapse
Affiliation(s)
- Yulia V. Plekhanova
- G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Pushchino Center for Biological Research of the Russian Academy of Sciences, 142290 Pushchino, Russian Federation
| | - Mahendra Rai
- Nanobiotechnology Laboratory, Department of Biotechnology, Sant Gadge Baba Amravati University, Amravati, MH 444602 India
| | - Anatoly N. Reshetilov
- G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Pushchino Center for Biological Research of the Russian Academy of Sciences, 142290 Pushchino, Russian Federation
- Tula State University, 300012 Tula, Russian Federation
| |
Collapse
|
2
|
Filik H, Avan AA. Electrochemical and Electrochemiluminescence Dendrimer-based Nanostructured Immunosensors for Tumor Marker Detection: A Review. Curr Med Chem 2021; 28:3490-3513. [PMID: 33076797 DOI: 10.2174/0929867327666201019143647] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 09/06/2020] [Accepted: 09/09/2020] [Indexed: 01/27/2023]
Abstract
The usage of dendrimers or cascade molecules in the biomedical area has recently attracted much attention worldwide. Furthermore, dendrimers are interesting in clinical and pre-clinical applications due to their unique characteristics. Cancer is one of the most widespread challenges and important diseases, which has the highest mortality rate. In this review, the recent advances and developments (from 2009 up to 2019) in the field of electrochemical and electroluminescence immunosensors for detection of the cancer markers are presented. Moreover, this review covers the basic fabrication principles and types of electrochemical and electrochemiluminescence dendrimer-based immunosensors. In this review, we have categorized the current dendrimer based-electrochemical/ electroluminescence immunosensors into five groups: dendrimer/ magnetic particles, dendrimer/ferrocene, dendrimer/metal nanoparticles, thiol-containing dendrimer, and dendrimer/quantum dots based-immunosensors.
Collapse
Affiliation(s)
- Hayati Filik
- Istanbul University-Cerrahpasa, Faculty of Engineering, Department of Chemistry, 34320 Avcilar, Istanbul, Turkey
| | - Asiye Aslıhan Avan
- Istanbul University-Cerrahpasa, Faculty of Engineering, Department of Chemistry, 34320 Avcilar, Istanbul, Turkey
| |
Collapse
|
3
|
Dendrimers as Soft Nanomaterials for Electrochemical Immunosensors. NANOMATERIALS 2019; 9:nano9121745. [PMID: 31817938 PMCID: PMC6955849 DOI: 10.3390/nano9121745] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 12/01/2019] [Accepted: 12/03/2019] [Indexed: 11/17/2022]
Abstract
Electrochemical immunosensors are antibody-based affinity biosensors with a high impact on clinical, environmental, food, and pharmaceutical analysis. In general, the analytical performance of these devices is critically determined by the materials and reagents used for their construction, signal production and amplification. Dendrimers are monodisperse and highly branched polymers with three-dimensional structures widely employed as “soft” nanomaterials in electrochemical immunosensor technology. This review provides an overview on the state-of-the-art in dendrimer-based electrochemical immunosensors, focusing on those using polyamidoamine and poly (propylene imine) dendrimers. Special emphasis is given to the most original methods recently reported for the construction of immunosensor architectures incorporating dendrimers, as well as to novel sensing approaches based on dendrimer-assisted signal enhancement strategies.
Collapse
|
4
|
Lee Y, Kim SS, Lee JH. Chemiluminescent dual-enzyme immunoassays capable of simultaneously quantifying carbohydrate antigen 19–9 and carcinoma embryonic antigen in a sample. Anal Chim Acta 2019; 1060:88-96. [DOI: 10.1016/j.aca.2019.01.048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 11/21/2018] [Accepted: 01/23/2019] [Indexed: 12/22/2022]
|
5
|
Advances in drug delivery, gene delivery and therapeutic agents based on dendritic materials. Future Med Chem 2019; 11:1791-1810. [DOI: 10.4155/fmc-2018-0452] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Dendrimers are synthetic polymers that grow in three dimensions into well-defined structures. Their morphological appearance resembles a number of trees connected by a common point. Dendritic nanoparticles have been studied for a large number of pharmaceutical and biomedical applications including gene and drug delivery, clinical diagnosis and MRI. Despite the application of dendrimers, research is still in its childhood in comparison with liposomes and other nanomaterials. They are now playing a key role in several therapeutic strategies, with dendrimer-based products in clinical trials. The aim of this review is to describe the state-of-the-art of biomedical applications of dendrimers – and dendrimer conjugates – such as drug and gene delivery and antiviral activity.
Collapse
|
6
|
Sun AL. A potentiometric immunosensor for enterovirus 71 based on bis-MPA-COOH dendrimer-doped AgCl nanospheres with a silver ion-selective electrode. Analyst 2018; 143:487-492. [PMID: 29227478 DOI: 10.1039/c7an01305a] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Herein a new potentiometric immunoassay for the point-of-care detection of enterovirus 71 (EV71) was developed by using a silver (Ag+) ion-selective electrode (ISE). Initially, the carboxylated dendrimer-doped AgCl nanospheres were synthesized by the reverse micelle method. Then the synthesized nanospheres were used to label a polyclonal mouse anti-EV71 antibody via a typical carbodiimide coupling method. The immunoreaction was executed on a monoclonal anti-EV71 antibody-coated microplate by using biofunctional AgCl nanospheres as the detection antibody. With a sandwich-type immunoassay format, the carried AgCl nanospheres could be dissolved in the presence of NH3·H2O, and the released silver ions were determined with an external silver ion-selective electrode. Under optimal conditions, the shift in the potential increased with the increase in the EV71 concentration, in a wide linear range of 0.3-300 ng mL-1, with a detection limit of 0.058 ng mL-1. Intra- and inter-assay relative standard deviations with identical batches were less than 4.15% and 6.15%, respectively. By validating the spiked serum samples, our system shows consistency with the enzyme-linked immunosorbent assay (ELISA) kit.
Collapse
Affiliation(s)
- Ai-Li Sun
- Department of Chemistry and Chemical Engineering, Xinxiang University, Xinxiang 453000, People's Republic of China.
| |
Collapse
|
7
|
Rama EC, Costa-García A. Screen-printed Electrochemical Immunosensors for the Detection of Cancer and Cardiovascular Biomarkers. ELECTROANAL 2016. [DOI: 10.1002/elan.201600126] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Estefanía Costa Rama
- Departamento de Química Física y Analítica, Facultad de Química; Universidad de Oviedo; 33006 Oviedo Spain
| | - Agustín Costa-García
- Departamento de Química Física y Analítica, Facultad de Química; Universidad de Oviedo; 33006 Oviedo Spain
| |
Collapse
|
8
|
Sun AL, Qi QA. Silver-functionalized g-C3N4 nanohybrids as signal-transduction tags for electrochemical immunoassay of human carbohydrate antigen 19-9. Analyst 2016; 141:4366-72. [PMID: 27183220 DOI: 10.1039/c6an00696e] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A simple and feasible electrochemical immunosensing platform was developed for highly efficient screening of a disease-related protein (human carbohydrate antigen 19-9, CA 19-9 used in this case) using silver-functionalized g-C3N4 nanosheets (Ag/g-C3N4) as signal-transduction tags. Initially, Ag/g-C3N4 nanohybrids were synthesized by combining thermal polymerization of the melamine precursor with the photo-assisted reduction method. Thereafter, the as-synthesized Ag/g-C3N4 nanohybrids were utilized for the labeling of the anti-CA 19-9 detection antibody by using a typical carbodiimide coupling method. The assay was carried out on a capture antibody-modified glassy carbon electrode in a sandwich-type detection mode. The detectable signal mainly derived from the voltammetric characteristics of the immobilized nanosilver particles on the g-C3N4 nanosheets within the applied potentials. Under the optimal conditions, the voltammetric peak currents increased with the increasing amount of target CA 19-9, and exhibited a wide linear range from 5.0 mU mL(-1) to 50 U mL(-1) with a detection limit of 1.2 mU mL(-1). Our strategy also displayed good reproducibility, precision and specificity. The results of the analysis of clinical serum specimens were in good accordance with the results obtained by an enzyme-linked immunosorbent assay (ELISA) method. The newly developed immunosensing system is promising for enzyme-free and cost-effective analysis of low-abundance proteins.
Collapse
Affiliation(s)
- Ai-Li Sun
- Department of Chemistry and Chemical Engineering, Xinxiang University, Xinxiang 453000, P.R. China.
| | | |
Collapse
|
9
|
Sun AL, Zhang YF, Sun GP, Wang XN, Tang D. Homogeneous electrochemical detection of ochratoxin A in foodstuff using aptamer-graphene oxide nanosheets and DNase I-based target recycling reaction. Biosens Bioelectron 2015; 89:659-665. [PMID: 26707001 DOI: 10.1016/j.bios.2015.12.032] [Citation(s) in RCA: 102] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2015] [Revised: 12/06/2015] [Accepted: 12/14/2015] [Indexed: 12/15/2022]
Abstract
A simple and feasible homogeneous electrochemical sensing protocol was developed for the detection of ochratoxin A (OTA) in foodstuff on the immobilization-free aptamer-graphene oxide nanosheets coupling with DNase I-based cycling signal amplification. Thionine-labeled OTA aptamers were attached to the surface of nanosheets because of the strong noncovalent binding of graphene oxide nanosheets with nucleobases and aromatic compounds. The electronic signal was acquired via negatively charged screen-printed carbon electrode (SPCE) toward free thionine molecules. Initially, the formed thionine-aptamer/graphene nanocomposites were suspended in the detection solution and far away from the electrode, thereby resulting in a weak electronic signal. Upon addition of target OTA, the analyte reacted with the aptamer and caused the dissociation of thionine-aptamer from the graphene oxide nanosheets. The newly formed thionine-aptamer/OTA could be readily cleaved by DNase I and released target OTA, which could retrigger thionine-aptamer/graphene nanocomposites with target recycling to generate numerous free thionine molecules. Free thionine molecules were captured by negatively charged SPCE, each of which could produce an electrochemical signal within the applied potentials. Under optimal conditions, graphene-based aptasensing platform could exhibit good electrochemical responses for the detection of OTA at a concentration as low as 5.6pg/mL. The reproducibility, precision and selectivity of the system were acceptable. Importantly, the method accuracy was comparable with commercialized OTA ELISA kit when using for quantitative monitoring of contaminated wheat samples.
Collapse
Affiliation(s)
- Ai-Li Sun
- Department of Chemistry and Chemical Engineering, Institute of Biotechnology, Xinxiang University, Xinxiang 453000, PR China.
| | - Yan-Fang Zhang
- Department of Chemistry and Chemical Engineering, Institute of Biotechnology, Xinxiang University, Xinxiang 453000, PR China; Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, PR China
| | - Guo-Peng Sun
- Department of Chemistry and Chemical Engineering, Institute of Biotechnology, Xinxiang University, Xinxiang 453000, PR China; Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, PR China
| | - Xuan-Nian Wang
- Department of Chemistry and Chemical Engineering, Institute of Biotechnology, Xinxiang University, Xinxiang 453000, PR China
| | - Dianping Tang
- Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, PR China
| |
Collapse
|