1
|
Rasekh M, Harrison S, Schobesberger S, Ertl P, Balachandran W. Reagent storage and delivery on integrated microfluidic chips for point-of-care diagnostics. Biomed Microdevices 2024; 26:28. [PMID: 38825594 DOI: 10.1007/s10544-024-00709-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/02/2024] [Indexed: 06/04/2024]
Abstract
Microfluidic-based point-of-care diagnostics offer several unique advantages over existing bioanalytical solutions, such as automation, miniaturisation, and integration of sensors to rapidly detect on-site specific biomarkers. It is important to highlight that a microfluidic POC system needs to perform a number of steps, including sample preparation, nucleic acid extraction, amplification, and detection. Each of these stages involves mixing and elution to go from sample to result. To address these complex sample preparation procedures, a vast number of different approaches have been developed to solve the problem of reagent storage and delivery. However, to date, no universal method has been proposed that can be applied as a working solution for all cases. Herein, both current self-contained (stored within the chip) and off-chip (stored in a separate device and brought together at the point of use) are reviewed, and their merits and limitations are discussed. This review focuses on reagent storage devices that could be integrated with microfluidic devices, discussing further issues or merits of these storage solutions in two different sections: direct on-chip storage and external storage with their application devices. Furthermore, the different microvalves and micropumps are considered to provide guidelines for designing appropriate integrated microfluidic point-of-care devices.
Collapse
Affiliation(s)
- Manoochehr Rasekh
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.
| | - Sam Harrison
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK
| | - Silvia Schobesberger
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9, 1060, Vienna, Austria
| | - Peter Ertl
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9, 1060, Vienna, Austria
| | - Wamadeva Balachandran
- College of Engineering, Design and Physical Sciences, Brunel University London, Uxbridge, UB8 3PH, UK.
| |
Collapse
|
2
|
Heidari-Bafroui H, Kumar A, Hahn C, Scholz N, Charbaji A, Rahmani N, Anagnostopoulos C, Faghri M. Development of a New Lab-on-Paper Microfluidics Platform Using Bi-Material Cantilever Actuators for ELISA on Paper. BIOSENSORS 2023; 13:310. [PMID: 36979522 PMCID: PMC10046564 DOI: 10.3390/bios13030310] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 02/16/2023] [Accepted: 02/22/2023] [Indexed: 06/18/2023]
Abstract
In this paper, we present a novel and cost-effective lab-on-paper microfluidics platform for performing ELISA autonomously, with no user intervention beyond adding the sample. The platform utilizes two Bi-Material Cantilever Valves placed in a specially designed housing. The integration of these valves in a specific channel network forms a complete fluidic logic circuit for performing ELISA on paper. The housing also incorporates an innovative reagent storage and release mechanism that minimizes variability in the volume of reagents released into the reagent pads. The platform design was optimized to minimize variance in the time of fluid wicking from the reagent pad, using a randomized design of experiment. The platform adheres to the World Health Organization's ASSURED principles. The optimized design was used to conduct an ELISA for detecting rabbit immunoglobulin G (IgG) in a buffer, with a limit of detection of 2.27 ng/mL and a limit of quantification of 8.33 ng/mL. This represents a 58% improvement over previous ELISA methods for detecting rabbit IgG in buffer using portable microfluidic technology.
Collapse
Affiliation(s)
- Hojat Heidari-Bafroui
- Microfluidics Laboratory, Department of Mechanical, Industrial, and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA
| | - Ashutosh Kumar
- Microfluidics Laboratory, Department of Mechanical, Industrial, and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA
| | - Cameron Hahn
- Microfluidics Laboratory, Department of Mechanical, Industrial, and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA
| | - Nicholas Scholz
- Microfluidics Laboratory, Department of Mechanical, Industrial, and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA
| | - Amer Charbaji
- Microfluidics Laboratory, Department of Mechanical, Industrial, and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA
| | - Nassim Rahmani
- Microfluidics Laboratory, Department of Mechanical, Industrial, and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA
| | - Constantine Anagnostopoulos
- Microfluidics Laboratory, Department of Mechanical, Industrial, and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA
| | - Mohammad Faghri
- Microfluidics Laboratory, Department of Mechanical, Industrial, and Systems Engineering, University of Rhode Island, 2 East Alumni Avenue, Kingston, RI 02881, USA
| |
Collapse
|
3
|
Zhang Q, Chen J, Zhong Z, Li B, Gai H. Aqueous two-phase systems evolved double-layer film for enzymatic activity preservation: A universal protein storage strategy for paper based microdevice. Anal Chim Acta 2022; 1197:339540. [DOI: 10.1016/j.aca.2022.339540] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 01/18/2022] [Accepted: 01/20/2022] [Indexed: 11/30/2022]
|
4
|
Boegner DJ, Everitt ML, White IM. Thermally Responsive Alkane Partitions for Assay Automation. ACS APPLIED MATERIALS & INTERFACES 2022; 14:8865-8875. [PMID: 35147027 PMCID: PMC10044609 DOI: 10.1021/acsami.2c00493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
For point-of-care diagnostic tools to be impactful, they must be inexpensive, equipment-free, and sample-to-answer (i.e., require no user intervention). Here, we report a new approach to enable sample-to-answer diagnostics that utilizes thermally responsive alkane partitions (TRAPs) as automated pseudo-valves. When combined with the magnetic manipulation of microbeads, TRAPs enable the pumpless automation of all steps in complex assays. We demonstrate that in relatively narrow channel geometries, liquified alkane partitions continue to separate reagents on each side of the partition while enabling the transition of magnetic beads from one reagent to the next, replacing manual pipetting steps in conventional assays. In addition, we show that in relatively broader geometries, liquified partitions breach, enabling the addition/mixing of preloaded reagents. Through calculation and experimentation, we determine the geometric design rules for implementing the stationary and removable partitions in fluidic channels. In addition, we demonstrate that magnetic microbeads can be pulled through liquified stationary TRAPs without disrupting partition integrity and without disrupting bound protein complexes attached at the microbead surface. The TRAP technology introduced here can enable a new low-cost and equipment-free approach for fully automated sample-to-answer diagnostics.
Collapse
Affiliation(s)
- David J Boegner
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| | - Micaela L Everitt
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| | - Ian M White
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| |
Collapse
|
5
|
Gu J, Norquist A, Brooks C, Repin M, Mukherjee S, Lacombe J, Yang J, Brenner DJ, Amundson S, Zenhausern F. Development of an integrated fingerstick blood self-collection device for radiation countermeasures. PLoS One 2019; 14:e0222951. [PMID: 31618210 PMCID: PMC6795524 DOI: 10.1371/journal.pone.0222951] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 09/10/2019] [Indexed: 01/22/2023] Open
Abstract
We report the development of system for packaging critical components of the traditional collection kit to make an integrated fingerstick blood collector for self-collecting blood samples of 100 μl or more for radiation countermeasures. A miniaturized vacuum tube system (VacuStor system) has been developed to facilitate liquid reagent storage, simple operation and reduced sample contamination. Vacuum shelf life of the VacuStor tube has been analyzed by the ideal gas law and gas permeation theory, and multiple ways to extend vacuum shelf life beyond one year have been demonstrated, including low temperature storage, Parylene barrier coating and container vacuum bag sealing. Self-collection was also demonstrated by healthy donors without any previous fingerstick collection experience. The collected blood samples showed similar behavior in terms of gene expression and cytogenetic biodosimetry assays comparing to the traditionally collected samples. The integrated collector may alleviate the sample collection bottleneck for radiation countermeasures following a large-scale nuclear event, and may be useful in other applications with its self-collection and liquid reagent sample preprocessing capabilities.
Collapse
Affiliation(s)
- Jian Gu
- Center for Applied NanoBioscience and Medicine, The University of Arizona, College of Medicine, Phoenix, AZ, United States of America
- * E-mail: (JG); (FZ)
| | - Alan Norquist
- Center for Applied NanoBioscience and Medicine, The University of Arizona, College of Medicine, Phoenix, AZ, United States of America
| | - Carla Brooks
- Center for Applied NanoBioscience and Medicine, The University of Arizona, College of Medicine, Phoenix, AZ, United States of America
| | - Mikhail Repin
- Center for Radiological Research, Columbia University, Vagelos College of Physicians and Surgeons, New York, NY, United States of America
| | - Sanjay Mukherjee
- Center for Radiological Research, Columbia University, Vagelos College of Physicians and Surgeons, New York, NY, United States of America
| | - Jerome Lacombe
- Center for Applied NanoBioscience and Medicine, The University of Arizona, College of Medicine, Phoenix, AZ, United States of America
| | - Jianing Yang
- Center for Applied NanoBioscience and Medicine, The University of Arizona, College of Medicine, Phoenix, AZ, United States of America
| | - David J. Brenner
- Center for Radiological Research, Columbia University, Vagelos College of Physicians and Surgeons, New York, NY, United States of America
| | - Sally Amundson
- Center for Radiological Research, Columbia University, Vagelos College of Physicians and Surgeons, New York, NY, United States of America
| | - Frederic Zenhausern
- Center for Applied NanoBioscience and Medicine, The University of Arizona, College of Medicine, Phoenix, AZ, United States of America
- * E-mail: (JG); (FZ)
| |
Collapse
|
6
|
Mauk MG, Song J, Liu C, Bau HH. Simple Approaches to Minimally-Instrumented, Microfluidic-Based Point-of-Care Nucleic Acid Amplification Tests. BIOSENSORS 2018; 8:E17. [PMID: 29495424 PMCID: PMC5872065 DOI: 10.3390/bios8010017] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 01/29/2018] [Accepted: 02/09/2018] [Indexed: 01/10/2023]
Abstract
Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges ('chips') that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed.
Collapse
Affiliation(s)
- Michael G Mauk
- Mechanical Engineering and Applied Mechanics (MEAM), School of Engineering and Applied Science, University of Pennsylvania, Towne Building, 220 33rd Street, Philadelphia, PA 19104, USA.
| | - Jinzhao Song
- Mechanical Engineering and Applied Mechanics (MEAM), School of Engineering and Applied Science, University of Pennsylvania, Towne Building, 220 33rd Street, Philadelphia, PA 19104, USA.
| | - Changchun Liu
- Mechanical Engineering and Applied Mechanics (MEAM), School of Engineering and Applied Science, University of Pennsylvania, Towne Building, 220 33rd Street, Philadelphia, PA 19104, USA.
| | - Haim H Bau
- Mechanical Engineering and Applied Mechanics (MEAM), School of Engineering and Applied Science, University of Pennsylvania, Towne Building, 220 33rd Street, Philadelphia, PA 19104, USA.
| |
Collapse
|
7
|
Zhang X, Wasserberg D, Breukers C, Terstappen LWMM, Beck M. Controlled antibody release from gelatin for on-chip sample preparation. Analyst 2016; 141:3068-76. [DOI: 10.1039/c5an02090e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Gelatin layers tailored for controlled release of antibody allow for optimized on-chip immunostaining of leukocytes in whole blood.
Collapse
Affiliation(s)
- Xichen Zhang
- Medical Cell Biophysics
- MIRA Institute for Biomedical Technology and Technical Medicine
- Faculty of Science and Technology
- 7500 AE Enschede
- The Netherlands
| | - Dorothee Wasserberg
- Medical Cell Biophysics
- MIRA Institute for Biomedical Technology and Technical Medicine
- Faculty of Science and Technology
- 7500 AE Enschede
- The Netherlands
| | - Christian Breukers
- Medical Cell Biophysics
- MIRA Institute for Biomedical Technology and Technical Medicine
- Faculty of Science and Technology
- 7500 AE Enschede
- The Netherlands
| | - Leon W. M. M. Terstappen
- Medical Cell Biophysics
- MIRA Institute for Biomedical Technology and Technical Medicine
- Faculty of Science and Technology
- 7500 AE Enschede
- The Netherlands
| | - Markus Beck
- Medical Cell Biophysics
- MIRA Institute for Biomedical Technology and Technical Medicine
- Faculty of Science and Technology
- 7500 AE Enschede
- The Netherlands
| |
Collapse
|