1
|
Huang D, Xie F, Xiao S, Cai M, Hu D, Ling B, Wang F, Lin X, Song F, Wang Q, Zhong T. Application of rapid genotyping of Warfarin individualized pharmacogenetic variants in Warfarin therapy. Sci Rep 2024; 14:31639. [PMID: 39738187 DOI: 10.1038/s41598-024-80639-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Accepted: 11/21/2024] [Indexed: 01/01/2025] Open
Abstract
Warfarin is the most widely used oral anticoagulant in clinical practice. The cytochrome P450 2C9 (CYP2C9), vitamin K epoxide reductase complex 1 (VKORC1), and cytochrome P450 4F2 (CYP4F2) genotypes are associated with warfarin dose requirements in China. Accurate genotyping is vital for obtaining reliable genotype-guided warfarin dosing information. The current method for individualized dosing gene polymorphism detection for warfarin has the disadvantages of being easily contaminated, time-consuming, expensive, and unsuitable for clinical use. Herein, we present a novel application, a multiplex fluorescent melting curve assay of whole-blood direct amplification of nested polymerase chain reaction (PCR), to genotyping single-nucleotide polymorphism (SNPs) rapidly that affect warfarin efficacy. This method requires only 1 µL of whole blood, no DNA extraction, takes less than 2 h, costs less than $1, and is able to accurately distinguish between different SNP sites. Polymorphic loci were detected in whole blood specimens of 181 clinical warfarin-administered patients through nested blood direct PCR fluorescence melting curve analysis and gene sequencing. The results of the nested blood direct PCR multiplex fluorescence melting curve technology were 100% consistent with those of sequencing-characterized by high accuracy and high specificity. The allele frequencies were 94.5% for A and 5.5% for C at CYP2C9*3 (rs1057910), 7.5% for G and 92.5% for A at VKORC1 (rs9923231), and 77.1% for G and 22.9% for A at CYP4F2*3 (rs2108622). For CYP2C9*2 (rs1799853), only allele C was detected, with a frequency of 100%. Warfarin doses were lower in the CYP2C9*1*1 genotype population than in the CYP2C9*1*3 population, lower in the VKORC1 (AA) population than in the VKORC1 (GG) population, and higher in individuals with the CYP4F2*3 mutation (GA/AA) compared with those with wild-type (GG). In summary, the detection and genotyping of four polymorphic SNP sites using a multiplex fluorescent melting curve assay of whole blood direct amplification through nested PCR is highly importance for guiding personalized warfarin anticoagulant therapy.
Collapse
Affiliation(s)
- Defa Huang
- Laboratory Medicine, First Affiliated Hospital of Gannan Medical University, Ganzhou, 341000, China
| | - Fangfang Xie
- Laboratory Medicine, First Affiliated Hospital of Gannan Medical University, Ganzhou, 341000, China
| | | | - Minyang Cai
- Jiangxi Shiningmed Medical Technology Ltd, Ganzhou, 341000, China
| | - Die Hu
- Laboratory Medicine, First Affiliated Hospital of Gannan Medical University, Ganzhou, 341000, China
| | - Baodian Ling
- Laboratory Medicine, First Affiliated Hospital of Gannan Medical University, Ganzhou, 341000, China
| | - Fangsheng Wang
- Laboratory Medicine, First Affiliated Hospital of Gannan Medical University, Ganzhou, 341000, China
| | - Xuan Lin
- Department of Trauma Center, First Affiliated Hospital of Gannan Medical University, Ganzhou, 341000, China
| | - Fangli Song
- Jiangxi Shiningmed Medical Technology Ltd, Ganzhou, 341000, China
| | - Qi Wang
- The First School of Clinical Medicine, Gannan Medical University, Ganzhou, 341000, China
| | - Tianyu Zhong
- Laboratory Medicine, First Affiliated Hospital of Gannan Medical University, Ganzhou, 341000, China.
| |
Collapse
|
2
|
Han J, Zhuang B, Zou L, Wang D, Jiang L, Wei YL, Zhao L, Zhao L, Li C. A developmental validation of the Quick TargSeq 1.0 integrated system for automated DNA genotyping in forensic science for reference samples. Electrophoresis 2024; 45:814-828. [PMID: 38459798 DOI: 10.1002/elps.202300187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 02/07/2024] [Accepted: 02/21/2024] [Indexed: 03/10/2024]
Abstract
Analysis of short tandem repeats (STRs) is a global standard method for human identification. Insertion/Deletion polymorphisms (DIPs) can be used for biogeographical ancestry inference. Current DNA typing involves a trained forensic worker operating several specialized instruments in a controlled laboratory environment, which takes 6-8 h. We developed the Quick TargSeq 1.0 integrated system (hereinafter abbreviated to Quick TargSeq) for automated generation of STR and DIP profiles from buccal swab samples and blood stains. The system fully integrates the processes of DNA extraction, polymerase chain reaction (PCR) amplification, and electrophoresis separation using microfluidic biochip technology. Internal validation studies were performed using RTyper 21 or DIP 38 chip cartridges with single-source reference samples according to the Scientific Working Group for DNA Analysis Methods guidelines. These results indicated that the Quick TargSeq system can process reference samples and generate STR or DIP profiles in approximately 2 h, and the profiles were concordant with those determined using traditional STR or DIP analysis methods. Thus, reproducible and concordant DNA profiles were obtained from reference samples. Throughout the study, no lane-to-lane or run-to-run contamination was observed. The Quick TargSeq system produced full profiles from buccal swabs with at least eight swipes, dried blood spot cards with two 2-mm disks, or 10 ng of purified DNA. Potential PCR inhibitors (i.e., coffee, smoking tobacco, and chewing tobacco) did not appear to affect the amplification reactions of the instrument. The overall success rate and concordance rate of 153 samples were 94.12% and 93.44%, respectively, which is comparable to other commercially available rapid DNA instruments. A blind test initiated by a DNA expert group showed that the system can correctly produce DNA profiles with 97.29% genotype concordance with standard bench-processing methods, and the profiles can be uploaded into the national DNA database. These results demonstrated that the Quick TargSeq system can rapidly generate reliable DNA profiles in an automated manner and has the potential for use in the field and forensic laboratories.
Collapse
Affiliation(s)
- Junping Han
- Technology Department of Chaoyang Sub-bureau, Beijing Public Security Bureau, Beijing, P. R. China
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, National Engineering Laboratory for Forensic Science, Institute of Forensic Science, Beijing, P. R. China
| | - Bin Zhuang
- Beijing CapitalBio Technology Ltd. Co., Beijing, P. R. China
| | - Lixin Zou
- Jiangsu Key Laboratory of Phylogenomics and Comparative Genomics, Jiangsu International Joint Center of Genomics, School of Life Sciences, Jiangsu Normal University, Xuzhou, Jiangsu, P. R. China
| | - Daoyu Wang
- People's Public Security University of China, Beijing, P. R. China
| | - Li Jiang
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, National Engineering Laboratory for Forensic Science, Institute of Forensic Science, Beijing, P. R. China
| | - Yi-Liang Wei
- Jiangsu Key Laboratory of Phylogenomics and Comparative Genomics, Jiangsu International Joint Center of Genomics, School of Life Sciences, Jiangsu Normal University, Xuzhou, Jiangsu, P. R. China
| | - Lijian Zhao
- Beijing CapitalBio Technology Ltd. Co., Beijing, P. R. China
| | - Lei Zhao
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, National Engineering Laboratory for Forensic Science, Institute of Forensic Science, Beijing, P. R. China
| | - Caixia Li
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, National Engineering Laboratory for Forensic Science, Institute of Forensic Science, Beijing, P. R. China
| |
Collapse
|
3
|
Cunha ML, da Silva SS, Stracke MC, Zanette DL, Aoki MN, Blanes L. Sample Preparation for Lab-on-a-Chip Systems in Molecular Diagnosis: A Review. Anal Chem 2021; 94:41-58. [PMID: 34870427 DOI: 10.1021/acs.analchem.1c04460] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Rapid and low-cost molecular analysis is especially required for early and specific diagnostics, quick decision-making, and sparing patients from unnecessary tests and hospitals from extra costs. One way to achieve this objective is through automated molecular diagnostic devices. Thus, sample-to-answer microfluidic devices are emerging with the promise of delivering a complete molecular diagnosis system that includes nucleic acid extraction, amplification, and detection steps in a single device. The biggest issue in such equipment is the extraction process, which is normally laborious and time-consuming but extremely important for sensitive and specific detection. Therefore, this Review focuses on automated or semiautomated extraction methodologies used in lab-on-a-chip devices. More than 15 different extraction methods developed over the past 10 years have been analyzed in terms of their advantages and disadvantages to improve extraction procedures in future studies. Herein, we are able to explain the high applicability of the extraction methodologies due to the large variety of samples in which different techniques were employed, showing that their applications are not limited to medical diagnosis. Moreover, we are able to conclude that further research in the field would be beneficial because the methodologies presented can be affordable, portable, time efficient, and easily manipulated, all of which are strong qualities for point-of-care technologies.
Collapse
Affiliation(s)
- Mylena Lemes Cunha
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil 81350-010
| | - Stella Schuster da Silva
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil 81350-010
| | - Mateus Cassaboni Stracke
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil 81350-010.,Paraná Institute of Molecular Biology, Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil 81350-010
| | - Dalila Luciola Zanette
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil 81350-010
| | - Mateus Nóbrega Aoki
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil 81350-010
| | - Lucas Blanes
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil 81350-010.,Paraná Institute of Molecular Biology, Professor Algacyr Munhoz Mader 3775 St., Curitiba, Paraná, Brazil 81350-010
| |
Collapse
|
4
|
Pahattuge TN, Freed IM, Hupert ML, Vaidyanathan S, Childers K, Witek MA, Weerakoon-Ratnayake K, Park D, Kasi A, Al-Kasspooles MF, Murphy MC, Soper SA. System Modularity Chip for Analysis of Rare Targets (SMART-Chip): Liquid Biopsy Samples. ACS Sens 2021; 6:1831-1839. [PMID: 33938745 DOI: 10.1021/acssensors.0c02728] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Liquid biopsies are becoming popular for managing a variety of diseases due to the minimally invasive nature of their acquisition, thus potentially providing better outcomes for patients. Circulating tumor cells (CTCs) are among the many different biomarkers secured from a liquid biopsy, and a number of efficient platforms for their isolation and enrichment from blood have been reported. However, many of these platforms require manual sample handling, which can generate difficulties when translating CTC assays into the clinic due to potential sample loss, contamination, and the need for highly specialized operators. We report a system modularity chip for the analysis of rare targets (SMART-Chip) composed of three task-specific modules that can fully automate processing of CTCs. The modules were used for affinity selection of the CTCs from peripheral blood with subsequent photorelease, simultaneous counting, and viability determinations of the CTCs and staining/imaging of the CTCs for immunophenotyping. The modules were interconnected to a fluidic motherboard populated with valves, interconnects, pneumatic control channels, and a fluidic network. The SMART-Chip components were made from thermoplastics via microreplication, which lowers the cost of production making it amenable to clinical implementation. The utility of the SMART-Chip was demonstrated by processing blood samples secured from colorectal cancer (CRC) and pancreatic ductal adenocarcinoma (PDAC) patients. We were able to affinity-select EpCAM expressing CTCs with high purity (0-3 white blood cells/mL of blood), enumerate the selected cells, determine their viability, and immunophenotype the cells. The assay could be completed in <4 h, while manual processing required >8 h.
Collapse
Affiliation(s)
- Thilanga N. Pahattuge
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, Kansas 66045, United States
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
| | - Ian M. Freed
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, Kansas 66045, United States
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
| | - Mateusz L. Hupert
- BioFluidica, Inc., 1567 Irving Hill Road, Lawrence, Kansas 66045, United States
| | - Swarnagowri Vaidyanathan
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
- Department of BioEngineering, University of Kansas, 1530 West 15th Street, Lawrence, Kansas 66045, United States
| | - Katie Childers
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
- Department of BioEngineering, University of Kansas, 1530 West 15th Street, Lawrence, Kansas 66045, United States
| | - Malgorzata A. Witek
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, Kansas 66045, United States
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
| | - Kumuditha Weerakoon-Ratnayake
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, Kansas 66045, United States
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
| | - Daniel Park
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
- Department of Mechanical & Industrial Engineering, Louisiana State University, 3261 Patrick F. Taylor Hall, Baton Rouge, Louisiana 70803, United States
| | - Anup Kasi
- Department of Medical Oncology, University of Kansas Medical Center, Kansas City, Kansas 66160, United States
| | - Mazin F Al-Kasspooles
- Department of Medical Oncology, University of Kansas Medical Center, Kansas City, Kansas 66160, United States
| | - Michael C. Murphy
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
- Department of Mechanical & Industrial Engineering, Louisiana State University, 3261 Patrick F. Taylor Hall, Baton Rouge, Louisiana 70803, United States
| | - Steven A. Soper
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, Kansas 66045, United States
- Center of BioModular Multi-scale Systems for Precision Medicine, University of Kansas, Lawrence, Kansas 66045, United States
- BioFluidica, Inc., 1567 Irving Hill Road, Lawrence, Kansas 66045, United States
- Department of BioEngineering, University of Kansas, 1530 West 15th Street, Lawrence, Kansas 66045, United States
- Department of Mechanical Engineering, University of Kansas, 3138 Learned Hall, 1530 West 15th Street, Lawrence, Kansas 66045, United States
| |
Collapse
|
5
|
Nouwairi RL, O'Connell KC, Gunnoe LM, Landers JP. Microchip Electrophoresis for Fluorescence-Based Measurement of Polynucleic Acids: Recent Developments. Anal Chem 2020; 93:367-387. [PMID: 33351599 DOI: 10.1021/acs.analchem.0c04596] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Renna L Nouwairi
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22903, United States
| | - Killian C O'Connell
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22903, United States
| | - Leah M Gunnoe
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22903, United States
| | - James P Landers
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22903, United States.,Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, Virginia 22903, United States.,Department of Pathology, University of Virginia Health Science Center, Charlottesville, Virginia 22903, United States
| |
Collapse
|
6
|
Ikonnikova AY, Filippova MA, Surzhikov SA, Pozhitnova VO, Kazakov RE, Lisitsa TS, Belkov SA, Nasedkina TV. Biochip-based approach for comprehensive pharmacogenetic testing. Drug Metab Pers Ther 2020; 36:dmdi-2020-0155. [PMID: 33780199 DOI: 10.1515/dmpt-2020-0155] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2020] [Accepted: 11/09/2020] [Indexed: 02/05/2023]
Abstract
OBJECTIVES Individual sensitivity to many widely used drugs is significantly associated with genetic factors. The purpose of our work was to develop an instrument for simultaneous determination of the most clinically relevant pharmacogenetic markers to allow personalized treatment, mainly in patients with cardiovascular diseases. METHODS Multiplex one-step polymerase chain reaction (PCR) followed by hybridization on a low-density biochip was applied to interrogate 15 polymorphisms in the following eight genes: VKORC1 -1639 G>A, CYP4F2 1297 G>A, GGCX 2374 C>G, CYP2C9 *2,*3 (430 C>T, 1075 A>C), CYP2D6 *3,*4, *6, *9, *41 (2549delA, 1846 G>A, 1707delT, 2615_2617delAAG, 2988 G>A), CYP2C19 *2,*3,*17 (681 G>A, 636 G>A, -806 C>T), ABCB1 (3435 C>T), SLCO1B1 *5. RESULTS Two hundred nineteen patients with cardiovascular diseases (CVD) and 48 female patients with estrogen receptor (ER)-positive breast cancer (BC) were genotyped. Of the 219 CVD patients, 203 (92.7%) carried one or more actionable at-risk genotypes based on VKORC1/CYP2C9, CYP2C9, CYP2C19, SLCO1B1, and CYP2D6 genotypes. Among them, 67 patients (30.6%) carried one, 58 patients (26.5%) carried two, 51 patients (23.3%) carried three, 26 patients (11.9%) carried four, and one patient (0.4%) carried five risk actionable genotypes. In the ER-positive BC group 12 patients (25%) were CYP2D6 intermediate or poor metabolizers. CONCLUSIONS The developed biochip is applicable for rapid and robust genotyping of patients who were taking a wide spectrum of medications to optimize drugs and dosage and avoid adverse drug reactions in cardiology, oncology, psychiatry, rheumatology and gastroenterology.
Collapse
Affiliation(s)
- Anna Yu Ikonnikova
- Engelhardt Institute of Molecular Biology, Russian Academy of Sciences, Moscow, Russia
| | - Marina A Filippova
- Engelhardt Institute of Molecular Biology, Russian Academy of Sciences, Moscow, Russia
| | - Sergey A Surzhikov
- Engelhardt Institute of Molecular Biology, Russian Academy of Sciences, Moscow, Russia
| | - Victoria O Pozhitnova
- Engelhardt Institute of Molecular Biology, Russian Academy of Sciences, Moscow, Russia
| | - Ruslan E Kazakov
- Federal State Budgetary Institution "Scientific Centre for Expert Evaluation of Medicinal Products" of the Ministry of Health of the Russian Federation, Moscow, Russia
| | - Tatiana S Lisitsa
- Moscow Clinical Scientific Center named after Loginov Moscow Healthcare Department, Moscow, Russia
| | - Sergey A Belkov
- Federal State Budgetary Institution "Scientific Centre for Expert Evaluation of Medicinal Products" of the Ministry of Health of the Russian Federation, Moscow, Russia
| | - Tatiana V Nasedkina
- Engelhardt Institute of Molecular Biology, Russian Academy of Sciences, Moscow, Russia
| |
Collapse
|
7
|
Ren P, Liu J, Zhao H, Fan XP, Xu YC, Li CX. Construction of a rapid microfluidic-based SNP genotyping (MSG) chip for ancestry inference. Forensic Sci Int Genet 2019; 41:145-151. [DOI: 10.1016/j.fsigen.2019.04.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 04/27/2019] [Accepted: 04/28/2019] [Indexed: 01/20/2023]
|
8
|
Gu Y, Zhuang B, Han J, Li Y, Song X, Zhou X, Wang L, Liu P. Modular-Based Integrated Microsystem with Multiple Sample Preparation Modules for Automated Forensic DNA Typing from Reference to Challenging Samples. Anal Chem 2019; 91:7435-7443. [PMID: 31050401 DOI: 10.1021/acs.analchem.9b01560] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The realization of an automated short tandem repeat (STR) analysis for forensic investigations is facing a unique challenge, that is DNA evidence with wide disparities in sample types, quality, and quantity. We developed a fully integrated microsystem in a modular-based architecture to accept and process various forensic samples in a "sample-in-answer-out" manner for forensic STR analysis. Two sample preparation modules (SPMs), the direct and the extraction SPM, were designed to be easily assembled with a capillary array electrophoresis (CAE) chip using a chip cartridge to efficiently achieve an adequate performance to different samples at a low cost. The direct SPM processed buccal swabs to produce STR profiles without DNA extraction in about 2 h. The extraction SPM analyzed more challenging blood samples based on chitosan-modified quartz filter paper for DNA extraction. This newly developed quartz filter provided a 90% DNA extraction efficiency and the "in situ" PCR capability, which enabled DNA extraction and PCR performed within a single chamber with all the DNA concentrated in the filter. We demonstrated that minute amounts of blood (0.25 μL), highly diluted blood (0.5 μL blood in 1 mL buffer), and latent bloodstains (5-μL bloodstain on cloth washed with detergent) can be automatically analyzed using our microsystem, reliably producing full STR profiles with a 100% calling of all the alleles. This modular-based microsystem with the capability of analyzing a wide range of samples should be able to play an increasing role in both urgent situations and routine forensic investigations, dramatically extending the applications and utility of automated DNA typing.
Collapse
Affiliation(s)
- Yin Gu
- Department of Biomedical Engineering, School of Medicine, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases , Tsinghua University , Beijing , 100084 , China.,State Key Laboratory of Space Medicine Fundamentals and Application , China Astronaut Research and Training Center , Beijing , 100094 , China
| | - Bin Zhuang
- Beijing CapitalBio Technology Ltd. Co. , Beijing , 101111 , China
| | - Junping Han
- Technology Department of Chaoyang Sub-bureau , Beijing Public Security Bureau , Beijing , 100102 , China
| | - Yi Li
- Beijing CapitalBio Technology Ltd. Co. , Beijing , 101111 , China
| | - Xiaoyu Song
- Beijing CapitalBio Technology Ltd. Co. , Beijing , 101111 , China
| | - Xinying Zhou
- CapitalBio Corporation , Beijing , 102206 , China
| | - Lei Wang
- CapitalBio Corporation , Beijing , 102206 , China
| | - Peng Liu
- Department of Biomedical Engineering, School of Medicine, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases , Tsinghua University , Beijing , 100084 , China
| |
Collapse
|
9
|
Yin J, Hu J, Sun J, Wang B, Mu Y. A fast nucleic acid extraction system for point-of-care and integration of digital PCR. Analyst 2019; 144:7032-7040. [DOI: 10.1039/c9an01067j] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
This work showcases a PTFE-based nucleic acid extraction system for point-of-care and integration of digital PCR.
Collapse
Affiliation(s)
- Juxin Yin
- Research Centre for Analytical Instrumentation
- Institute of Cyber-Systems and Control
- State Key Laboratory of Industrial Control Technology
- Zhejiang University
- Hangzhou
| | - Jiumei Hu
- Research Centre for Analytical Instrumentation
- Institute of Cyber-Systems and Control
- State Key Laboratory of Industrial Control Technology
- Zhejiang University
- Hangzhou
| | - Jingjing Sun
- Research Centre for Analytical Instrumentation
- Institute of Cyber-Systems and Control
- State Key Laboratory of Industrial Control Technology
- Zhejiang University
- Hangzhou
| | - Ben Wang
- Cancer Institute (Key Laboratory of Cancer Prevention and Intervention
- National Ministry of Education)
- The Second Affiliated Hospital
- Zhejiang University School of Medicine
- Hangzhou
| | - Ying Mu
- Research Centre for Analytical Instrumentation
- Institute of Cyber-Systems and Control
- State Key Laboratory of Industrial Control Technology
- Zhejiang University
- Hangzhou
| |
Collapse
|
10
|
An automated microfluidic chemiluminescence immunoassay platform for quantitative detection of biomarkers. Biomed Microdevices 2018; 20:91. [DOI: 10.1007/s10544-018-0331-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
11
|
Hui J, Gu Y, Zhu Y, Chen Y, Guo SJ, Tao SC, Zhang Y, Liu P. Multiplex sample-to-answer detection of bacteria using a pipette-actuated capillary array comb with integrated DNA extraction, isothermal amplification, and smartphone detection. LAB ON A CHIP 2018; 18:2854-2864. [PMID: 30105321 DOI: 10.1039/c8lc00543e] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
A pipette-actuated capillary array comb (PAAC) system operated on a smartphone-based hand-held device has been successfully developed for the multiplex detection of bacteria in a "sample-to-answer" manner. The PAAC consists of eight open capillaries inserted into a cylindrical plastic base with a piece of chitosan-modified glass filter paper embedded in each capillary. During the sample preparation, a PAAC was mounted into a 1 mL pipette tip with an enlarged opening and was operated with a 1 mL pipette for liquid handling. The cell lysate was drawn and expelled through the capillaries three times to facilitate the DNA capture on the embedded filter discs. Following washes with water, the loop-mediated isothermal amplification (LAMP) reagents were aspirated into the capillaries, in which the primers were pre-fixed with chitosan. After that, the PAAC was loaded into the smartphone-based device for a one-hour amplification at 65 °C and end-point detection of calcein fluorescence in the capillaries. The DNA capture efficiency of a 1.1 mm-diameter filter disc was determined to be 97% of λ-DNA and the coefficient of variation among the eight capillaries in the PAAC was only 2.2%. The multiplex detection of genomic DNA extracted from Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus provided limits of detection of 200, 500, and 500 copies, respectively, without any cross-contamination and cross reactions. "Sample-to-answer" detection of E. coli samples was successfully completed in 85 minutes, demonstrating a sensitivity of 200 cfu per capillary. The multiplex "sample-to-answer" detection, the streamlined operation, and the compact device should facilitate a broad range of applications of our PAAC system in point-of-care testing.
Collapse
Affiliation(s)
- Junhou Hui
- Department of Biomedical Engineering, School of Medicine, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Tsinghua University, Beijing, 100084, China.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Wuethrich A, Quirino JP. A decade of microchip electrophoresis for clinical diagnostics - A review of 2008-2017. Anal Chim Acta 2018; 1045:42-66. [PMID: 30454573 DOI: 10.1016/j.aca.2018.08.009] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 07/30/2018] [Accepted: 08/03/2018] [Indexed: 01/10/2023]
Abstract
A core element in clinical diagnostics is the data interpretation obtained through the analysis of patient samples. To obtain relevant and reliable information, a methodological approach of sample preparation, separation, and detection is required. Traditionally, these steps are performed independently and stepwise. Microchip capillary electrophoresis (MCE) can provide rapid and high-resolution separation with the capability to integrate a streamlined and complete diagnostic workflow suitable for the point-of-care setting. Whilst standard clinical diagnostics methods normally require hours to days to retrieve specific patient data, MCE can reduce the time to minutes, hastening the delivery of treatment options for the patients. This review covers the advances in MCE for disease detection from 2008 to 2017. Miniaturised diagnostic approaches that required an electrophoretic separation step prior to the detection of the biological samples are reviewed. In the two main sections, the discussion is focused on the technical set-up used to suit MCE for disease detection and on the strategies that have been applied to study various diseases. Throughout these discussions MCE is compared to other techniques to create context of the potential and challenges of MCE. A comprehensive table categorised based on the studied disease using MCE is provided. We also comment on future challenges that remain to be addressed.
Collapse
Affiliation(s)
- Alain Wuethrich
- Centre for Personalised Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), University of Queensland, Building 75, Brisbane, QLD, 4072, Australia
| | - Joselito P Quirino
- Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences-Chemistry, University of Tasmania, Private Bag 75, Hobart, TAS, 7001, Australia.
| |
Collapse
|
13
|
Han J, Gan W, Zhuang B, Sun J, Zhao L, Ye J, Liu Y, Li CX, Liu P. A fully integrated microchip system for automated forensic short tandem repeat analysis. Analyst 2018; 142:2004-2012. [PMID: 28513665 DOI: 10.1039/c7an00295e] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We have successfully developed an integrated microsystem that combines two plastic microchips for DNA extraction and PCR amplification with a glass capillary array electrophoresis chip together in a compact control and detection instrument for automated forensic short tandem repeat (STR) analysis. DNA extraction followed by an "in situ PCR" was conducted in a single reaction chamber of the microchip based on a filter paper-based extraction methodology. PCR products were then mixed with sizing standards by an injection electrode and injected into the electrophoresis chip for four-color confocal fluorescence detection. The entire STR analysis can be completed in about two hours without any human intervention. Since the 15-plex STR system has a more stringent requirement for PCR efficiency, we optimized the structure of the plastic DNA extraction and amplification chip, in which the reaction chamber was formed by sandwiching a hollow structure layer with two blank cover layers, to reduce the adsorption of PCR reagents to the surfaces. In addition, PCR additives, bovine serum albumin, poly(ethylene glycol), and more magnesium chloride were included into the on-chip multiplex STR system. The limit-of-detection study demonstrated that our microsystem was able to produce full 15-plex STR profiles from 3.75 ng standard K562 DNA. Buccal swab and whole blood samples were also successfully typed by our system, validating the feasibility of performing rapid DNA typing in a "sample-in-answer-out" manner for on-site forensic human identification.
Collapse
Affiliation(s)
- Junping Han
- Department of Biomedical Engineering, School of Medicine, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Tsinghua University, Beijing, 100084, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Uehara M. Development of a Novel and Rapid Fully Automated Genetic Testing System. ANAL SCI 2018; 32:1375-1379. [PMID: 27941272 DOI: 10.2116/analsci.32.1375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
We have developed a rapid genetic testing system integrating nucleic acid extraction, purification, amplification, and detection in a single cartridge. The system performs real-time polymerase chain reaction (PCR) after nucleic acid purification in a fully automated manner. RNase P, a housekeeping gene, was purified from human nasal epithelial cells using silica-coated magnetic beads and subjected to real-time PCR using a novel droplet-real-time-PCR machine. The process was completed within 13 min. This system will be widely applicable for research and diagnostic uses.
Collapse
Affiliation(s)
- Masayuki Uehara
- Core Technology Development Center, Corporate Research and Development Div., Seiko Epson Corporation
| |
Collapse
|
15
|
Owens CE, Hart AJ. High-precision modular microfluidics by micromilling of interlocking injection-molded blocks. LAB ON A CHIP 2018; 18:890-901. [PMID: 29372201 DOI: 10.1039/c7lc00951h] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Wider use and adaptation of microfluidics is hindered by the infrastructure, knowledge, and time required to build prototype systems, especially when multiple fluid operations and measurements are required. As a result, 3D printing of microfluidics is attracting interest, yet cannot readily achieve the feature size, smoothness, and optical transparency needed for many standard microfluidic systems. Herein we present a new approach to the design and construction of high-precision modular microfluidics, using standard injection-molded blocks that are modified using micromilling and assembled via elastically averaged contacts. Desktop micromilling achieves channel dimensions as small as 50 μm depth and 150 μm width and adhesive films seal channels to allow internal fluid pressure of >400 kPa. Elastically averaged connections between bricks result in a mechanical locating repeatability of ∼1 μm, enabling fluid to pass between bricks via an O-ring seal with >99.9% reliability. We demonstrated and tested block-based systems for generating droplets at rates above 9000 min-1 and COV <3%, and integrated optical sensors. We also show how blocks can be used to build easily reconfigurable interfaces with glass microfluidic devices and imaging hardware. Microfluidic bricks fabricated by FDM and SLA 3D printing cannot achieve the dimensional quality of molded bricks, yet 3D printing allows customized bricks to be integrated with standard LEGOs. Our approach enables a wide variety of modular microfluidic units to be built using a widely available, cost-effective platform, encouraging use in both research and education.
Collapse
Affiliation(s)
- Crystal E Owens
- Department of Mechanical Engineering and Laboratory for Manufacturing and Productivity, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA.
| | | |
Collapse
|
16
|
Zizzari A, Bianco M, del Mercato L, Carraro M, Bonchio M, Frigione M, Montagna F, Gigli G, Viola I, Arima V. Self-powered catalytic microfluidic platforms for fluid delivery. Colloids Surf A Physicochem Eng Asp 2017. [DOI: 10.1016/j.colsurfa.2017.05.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
17
|
Hu B, Li J, Mou L, Liu Y, Deng J, Qian W, Sun J, Cha R, Jiang X. An automated and portable microfluidic chemiluminescence immunoassay for quantitative detection of biomarkers. LAB ON A CHIP 2017; 17:2225-2234. [PMID: 28573279 DOI: 10.1039/c7lc00249a] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Microfluidic platforms capable of automated, rapid, sensitive, and quantitative detection of biomarkers from patient samples could make a major impact on clinical or point-of-care (POC) diagnosis. In this work, we realize an automated diagnostic platform composed of two main components: (1) a disposable, self-contained, and integrated microfluidic chip and (2) a portable instrument that carries out completely automated operations. To demonstrate its potential for real-world application, we use injection molding for mass fabrication of the main components of disposable microfluidic chips. The assembled three-layered chip with on-chip mechanical valves for fluid control consists of (1) a top silicone fluidic layer with embedded zigzag microchannels, reagent reservoirs and a negative pressure port, (2) a middle tinfoil layer with patterned antibody/antigen stripes, and (3) a bottom silicone substrate layer with waste reservoirs. The versatility of the microfluidics-based system is demonstrated by implementation of a chemiluminescence immunoassay for quantitative detection of C-reactive protein (CRP) and testosterone in real clinical samples. This lab-on-a-chip platform with features of quantitation, portability and automation provides a promising strategy for POC diagnosis.
Collapse
Affiliation(s)
- Binfeng Hu
- CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, P. R. China.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Gan W, Gu Y, Han J, Li CX, Sun J, Liu P. Chitosan-Modified Filter Paper for Nucleic Acid Extraction and "in Situ PCR" on a Thermoplastic Microchip. Anal Chem 2017; 89:3568-3575. [PMID: 28230980 DOI: 10.1021/acs.analchem.6b04882] [Citation(s) in RCA: 61] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Plastic microfluidic devices with embedded chitosan-modified Fusion 5 filter paper (unmodified one purchased from GE Healthcare) have been successfully developed for DNA extraction and concentration, utilizing two different mechanisms for DNA capture: the physical entanglement of long-chain DNA molecules with the fiber matrix of the filter paper and the electrostatic adsorption of DNA to the chitosan-modified filter fibers. This new method not only provided a high DNA extraction efficiency at a pH of 5 by synergistically combining these two capture mechanisms together, but also resisted the elution of DNA from filters at a pH > 8 due to the entanglement of DNA with fibers. As a result, PCR buffers can be directly loaded into the extraction chamber for "in situ PCR", in which the captured DNA were used for downstream analysis without any loss. We demonstrated that the capture efficiencies of a 3-mm-diameter filter disc in a microchip were 98% and 95% for K562 human genomic DNA and bacteriophage λ-DNA, respectively. The washes with DI water, PCR mixture, and TE buffer cannot elute the captured DNA. In addition, the filter disc can enrich 62% of λ-DNA from a diluted sample (0.05 ng/μL), providing a concentration factor more than 30-fold. Finally, a microdevice with a simple two-chamber structure was developed for on-chip cell lysis, DNA extraction, and 15-plex short tandem repeat amplification from blood. This DNA extraction coupled with "in situ PCR" has great potential to be utilized in fully integrated microsystems for rapid, near-patient nucleic acid testing.
Collapse
Affiliation(s)
- Wupeng Gan
- Department of Biomedical Engineering, School of Medicine, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Tsinghua University , Beijing 100084, China
| | - Yin Gu
- Department of Biomedical Engineering, School of Medicine, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Tsinghua University , Beijing 100084, China
| | - Junping Han
- Technology Department of Chaoyang Sub-bureau, Beijing Public Security Bureau , Beijing 100102, China
| | - Cai-Xia Li
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, National Engineering Laboratory for Crime Scene Evidence Examination, Institute of Forensic Science , Beijing 100038, China
| | - Jing Sun
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, National Engineering Laboratory for Crime Scene Evidence Examination, Institute of Forensic Science , Beijing 100038, China
| | - Peng Liu
- Department of Biomedical Engineering, School of Medicine, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Tsinghua University , Beijing 100084, China
| |
Collapse
|
19
|
Electrode Materials in Microfluidic Systems for the Processing and Separation of DNA: A Mini Review. MICROMACHINES 2017. [PMCID: PMC6190325 DOI: 10.3390/mi8030076] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Since the advent of genetic analysis, electrode materials have played an irreplaceable role due to the easily-exploitable negatively-charged backbone of the DNA structure. Initially, the employment of electrophoretic movement lay only in the separation of DNA fragments of differing length; however, the widening utility of electrokinetic phenomena at the microscale in areas such as fluid transportation and multistep integration led researchers to capitalize further when translating processes to microfluidic or “lab-on-chip” devices. Over the following three decades, the field witnessed a plethora of ways in which the necessary voltages could be transmitted to the sample and reagents with many successes; however, additional demands were then placed on those hoping to bring their microdevices to the market place. A greater emphasis on the cost of all constituent parts along with the increased importance that fluidics be contained hermetically at all times meant groups would become more imaginative when incorporating electrode materials. This review will aim to exactly describe the evolution of how those materials have been employed in DNA-based microfluidic devices. It will focus on how developers began to explore other emerging uses and also discuss how their tactics reflected the progressive demands of their chosen industry.
Collapse
|
20
|
Han JP, Sun J, Wang L, Liu P, Zhuang B, Zhao L, Liu Y, Li CX. The Optimization of Electrophoresis on a Glass Microfluidic Chip and its Application in Forensic Science. J Forensic Sci 2017; 62:1603-1612. [PMID: 28168694 DOI: 10.1111/1556-4029.13408] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 10/23/2016] [Accepted: 11/29/2016] [Indexed: 11/29/2022]
Abstract
Microfluidic chips offer significant speed, cost, and sensitivity advantages, but numerous parameters must be optimized to provide microchip electrophoresis detection. Experiments were conducted to study the factors, including sieving matrices (the concentration and type), surface modification, analysis temperature, and electric field strengths, which all impact the effectiveness of microchip electrophoresis detection of DNA samples. Our results showed that the best resolution for ssDNA was observed using 4.5% w/v (7 M urea) lab-fabricated LPA gel, dynamic wall coating of the microchannel, electrophoresis temperatures between 55 and 60°C, and electrical fields between 350 and 450 V/cm on the microchip-based capillary electrophoresis (μCE) system. One base-pair resolution could be achieved in the 19-cm-length microchannel. Furthermore, both 9947A standard genomic DNA and DNA extracted from blood spots were demonstrated to be successfully separated with well-resolved DNA peaks in 8 min. Therefore, the microchip electrophoresis system demonstrated good potential for rapid forensic DNA analysis.
Collapse
Affiliation(s)
- Jun P Han
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China.,Forensic Science and Technology Department of Chaoyang Sub-bureau, Beijing Public Security Bureau, Beijing, 100102, China
| | - Jing Sun
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| | - Le Wang
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| | - Peng Liu
- Tsinghua University, Beijing, 100084, China
| | - Bin Zhuang
- Tsinghua University, Beijing, 100084, China
| | - Lei Zhao
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| | - Yao Liu
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| | - Cai X Li
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| |
Collapse
|
21
|
Kumar P, Kumar V, Gupta R. Detection of the anticoagulant drug warfarin by palladium complexes. Dalton Trans 2017; 46:10205-10209. [DOI: 10.1039/c7dt01811h] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This work illustrates the application of palladium complexes in the significant sensing of warfarin, a commercial anticoagulant drug, not only in organic solvents but also in aqueous medium.
Collapse
Affiliation(s)
- Pramod Kumar
- Department of Chemistry
- University of Delhi
- Delhi 110 007
- India
| | - Vijay Kumar
- Department of Chemistry
- University of Delhi
- Delhi 110 007
- India
| | - Rajeev Gupta
- Department of Chemistry
- University of Delhi
- Delhi 110 007
- India
| |
Collapse
|
22
|
Sloane HS, Carter MB, Cecil AEC, Le Roux D, Mills DL, Landers JP. Warfarin genotyping with hybridization-induced aggregation on a poly(ethylene terephthalate) microdevice. Analyst 2017; 142:366-374. [DOI: 10.1039/c6an02325h] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel genotyping method is established, using allele-specific PCR followed by hybridization-induced aggregation (HIA) of microbeads on a multiplexed microdevice.
Collapse
Affiliation(s)
| | | | | | | | - Daniel L. Mills
- Department of Chemistry
- University of Virginia
- Charlottesville
- USA
| | - James P. Landers
- Department of Chemistry
- University of Virginia
- Charlottesville
- USA
- Department of Pathology
| |
Collapse
|
23
|
Haga SB. Challenges of development and implementation of point of care pharmacogenetic testing. Expert Rev Mol Diagn 2016; 16:949-60. [PMID: 27402403 DOI: 10.1080/14737159.2016.1211934] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
INTRODUCTION Just as technology was the underlying driver of the sequencing of the human genome and subsequent generation of volumes of genome sequence data from healthy and affected individuals, animal, plant, and microbial species alike, so too will technology revolutionize diagnostic testing. One area of intense interest is the use of genetic data to inform decisions regarding drug selection and drug dosing, known as pharmacogenetic (PGx) testing, to improve likelihood of successful treatment outcomes with minimal risks. AREAS COVERED This commentary will provide an overview of implementation research of PGx testing, the benefits of point-of-care (POC) testing and overview of POC testing platforms, available PGx tests, and barriers and facilitators to the development and integration of POC-PGx testing into clinical settings. Sources include the published literature, and databases from the Centers for Medicaid and Medicare Services, Food and Drug Administration. Expert commentary: The utilization of POC PGx testing may enable more routine test use, but the development and implementation of such tests will face some barriers before personalized medicine is available to every patient. In particular, provider training, availability of clinical decision supports, and connectivity will be key areas to facilitate routine use.
Collapse
Affiliation(s)
- Susanne B Haga
- a Department of Medicine, Center for Applied Genomics and Precision Medicine , Duke University School of Medicine , Durham , NC , USA
| |
Collapse
|
24
|
Valiadi M, Kalsi S, Jones IGF, Turner C, Sutton JM, Morgan H. Simple and rapid sample preparation system for the molecular detection of antibiotic resistant pathogens in human urine. Biomed Microdevices 2016; 18:18. [PMID: 26846875 PMCID: PMC4742488 DOI: 10.1007/s10544-016-0031-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Antibiotic resistance in urinary tract infections (UTIs) can cause significant complications without quick detection and appropriate treatment. We describe a new approach to capture, concentrate and prepare amplification-ready DNA from antibiotic resistant bacteria in human urine samples. Klebsiella pneumoniae NCTC13443 (bla CTX-M-15 positive) spiked into filtered human urine was used as a model system. Bacteria were captured using anion exchange diaethylaminoethyl (DEAE) magnetic microparticles and concentrated 200-fold within ~3.5 min using a custom, valve-less microfluidic chip. Eight samples were processed in parallel, and DNA was released using heat lysis from an integrated resistive heater. The crude cell lysate was used for real time Recombinase Polymerase Amplification (RPA) of the bla CTX-M-15 gene. The end to end processing time was approximately 15 min with a limit of detection of 1000 bacteria in 1 mL urine.
Collapse
Affiliation(s)
- Martha Valiadi
- Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK
- Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ, UK
| | - Sumit Kalsi
- Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK
- Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ, UK
| | - Isaac G F Jones
- Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK
- Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ, UK
| | - Carrie Turner
- National Infections Service, Public Health England, Porton Down, Salisbury, SP4 0JG, UK
| | - J Mark Sutton
- National Infections Service, Public Health England, Porton Down, Salisbury, SP4 0JG, UK
| | - Hywel Morgan
- Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK.
- Institute for Life Sciences, University of Southampton, Southampton, SO17 1BJ, UK.
| |
Collapse
|