1
|
Pourmadadi M, Nouralishahi A, Shalbaf M, Shabani Shayeh J, Nouralishahi A. An electrochemical aptasensor for detection of prostate-specific antigen-based on carbon quantum dots-gold nanoparticles. Biotechnol Appl Biochem 2023; 70:175-183. [PMID: 35307872 DOI: 10.1002/bab.2340] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Accepted: 02/28/2022] [Indexed: 11/11/2022]
Abstract
In this work, an electrochemical aptasensor was described for the determination of prostate-specific antigen (PSA). Aptamer chains were decorated on the surface of a glassy carbon electrode (GCE) via carbon quantum dots/Au nanoparticles (Au/CQD). Structural analysis that was used to characterize the prepared materials shows that Au/CQD nanoparticles synthesized in a spherical shape with an average size of 70 nm. Furthermore, the combination of Au nanoparticles with CQD resulted in formation of crystalline the structure of the Au/CQD composite. To study the electrochemical performance of the prepared aptasensor, cyclic voltammetry, square wave voltammetry, and electrochemical impedance spectroscopy were used. The results show that the aptasensor has a good selectivity to PSA over other biomaterials with the time optimized about 30 min. K4 [Fe(CN)6 ] was used as an electrochemical probe with the limit of detection about 2 fg⋅mL-1 . To avoid the hazardous nature of K4 [Fe(CN)6 ], a label-based aptasensor was prepared using methylene blue as an electrochemical signal producer. They provide the capability of electrochemical detection in buffer phosphate solution with high sensitivity.
Collapse
Affiliation(s)
| | | | - Mohammad Shalbaf
- Protein Research Center, Shahid Beheshti University, Tehran, Iran
| | | | - Amideddin Nouralishahi
- Energy, Environment, and Nanostructure Material Laboratory, Caspian Faculty of Engineering, College of Engineering, University of Tehran, Iran
| |
Collapse
|
2
|
Hwang EY, Lee JH, Lim DW. Janus bimetallic nanorod clusters-poly(aniline) nanocomposites with temperature-responsiveness for Raman scattering-based biosensing. J Mater Chem B 2021; 9:5293-5308. [PMID: 34137769 DOI: 10.1039/d1tb00699a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Herein, Janus bimetallic nanorod clusters-poly(aniline) nanocomposites (JRCPCs) with gold nanorod clusters (GNRCs) in side-by-side (SBS) or end-to-end (ETE) configuration are synthesized, and applied to surface-enhanced Raman scattering (SERS)-based biosensing of carcinoembryonic antigen (CEA). Taking advantage of their geometrical and chemical anisotropy, GNRCs in both SBS and ETE configurations are prepared by addition of negatively charged citrate anions and poly(acrylic acid)-block-poly(N-isopropylacrylamide) (PAAc-b-PNIPAM), respectively, to electrostatically interact with cationic cetyltrimethylammonium bromide surfactant on the side of the gold nanorods (GNRs). Subsequently, the JRCPCs are prepared by unidirectional growth of polyaniline and additional growth of Ag onto these GNRCs. JRCPCs with GNRCs in either the SBS or the ETE configuration show strong enhancement of electromagnetic field at both GNR aggregates and GNRC core-Ag shell gaps of bimetallic nanorod cluster components. In particular, because temperature-responsive PAAc-b-PNIPAM of JRCPCs is embedded at GNR junctions, interparticle gaps generated in GNRCs in ETE configuration are controlled via temperature-triggered hydration-dehydration of the PAAc-b-PNIPAM chains such that optical properties are largely changed. With distinct surface functionalities from JRCPCs, SERS-based quantitative analysis of CEA is achieved using JRCPCs as SERS nanoprobes. This work presents the great potential of advanced Janus nanocomposites for SERS-based biosensing applications.
Collapse
Affiliation(s)
- Eun Young Hwang
- Department of Bionano Engineering and Department of Bionanotechnology, Center for Bionano Intelligence Education and Research, Hanyang University, Ansan, Republic of Korea.
| | - Jae Hee Lee
- Department of Bionano Engineering and Department of Bionanotechnology, Center for Bionano Intelligence Education and Research, Hanyang University, Ansan, Republic of Korea.
| | - Dong Woo Lim
- Department of Bionano Engineering and Department of Bionanotechnology, Center for Bionano Intelligence Education and Research, Hanyang University, Ansan, Republic of Korea.
| |
Collapse
|
3
|
Zhao B, Miao P, Hu Z, Zhang X, Geng X, Chen Y, Feng L. Signal-on electrochemical aptasensors with different target-induced conformations for prostate specific antigen detection. Anal Chim Acta 2021; 1152:338282. [PMID: 33648646 DOI: 10.1016/j.aca.2021.338282] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 01/03/2021] [Accepted: 01/31/2021] [Indexed: 02/06/2023]
Abstract
Prostate specific antigen (PSA) has become a potential biomarker for detecting prostate cancer (PCa) in the early stage. Herein, we report a target-induced resolution for the detection of PSA sensitively and specifically by amperometric electrochemical measurements. To meet a satisfactory performance, three conformations of pre-design DNA aptamers including two stem-loop structures and a double strand structure have been investigated and compared. All of them are immobilized on gold electrode as capture probes with redox-active molecular. The mechanism of signal transduction depends on molecular recognition events involving aptamer conformational changes, thus influencing the charge transfer. A short, single-stranded DNA (ssDNA) pseudoknot forming two stem-loop structural aptamers with labeled MB at the 3' -terminus was found to posse the highest signal variation than other structure when induced by PSA due to the strong conformational change. With the optimized capture strand, the aptasensor showed the peak current increase of MB by the binding relationship between PSA and the sensor over a wide concentration range of 4 magnitude orders. The proposed aptasensor exhibited a wide detection range from 10 pg/mL to 500 ng/mL with a low detection limit of 1.24 pg/mL (S/N = 3). Moreover, the electrochemical aptasensor demonstrated good reproducibility, sensitivity, selectivity, and reliability for the detection of PSA. We also found the aptasensor had a good response in the human serum samples, making this device easy to operate for the detection of the PSA physiological concentration.
Collapse
Affiliation(s)
- Biying Zhao
- Materials Genome Institute, Shanghai University, China
| | - Ping Miao
- Renji Hospital, Shanghai Jiaotong University School of Medicine, 160th Pujian Road, Shanghai, China
| | - Ziheng Hu
- Materials Genome Institute, Shanghai University, China
| | - Xinying Zhang
- Materials Genome Institute, Shanghai University, China
| | - Xue Geng
- Nanjing Normal University, Coll Chem & Mat Sci, Nanjing, 210046, Jiangsu, China
| | - Yingying Chen
- Materials Genome Institute, Shanghai University, China
| | - Lingyan Feng
- Materials Genome Institute, Shanghai University, China.
| |
Collapse
|
4
|
Usman A. Nanoparticle enhanced optical biosensing technologies for Prostate Specific Antigen biomarker detection. IEEE Rev Biomed Eng 2020; 15:122-137. [PMID: 33136544 DOI: 10.1109/rbme.2020.3035273] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Prostate Cancer (PCa) is one of the deadliest forms of Cancer among men. Early screening process for PCa is primarily conducted with the help of a FDA approved biomarker known as Prostate Specific Antigen (PSA). The PSA-based screening is challenged with the inability to differentiate between the cancerous PSA and Benign Prostatic Hyperplasia (BPH), resulting in high rates of false-positives. Optical techniques such as optical absorbance, scattering, surface plasmon resonance (SPR), and fluorescence have been extensively employed for Cancer diagnostic applications. One of the most important diagnostic applications involves utilization of nanoparticles (NPs) for highly specific, sensitive, rapid, multiplexed, and high performance Cancer detection and quantification. The incorporation of NPs with these optical biosensing techniques allow realization of low cost, point-of-care, highly sensitive, and specific early cancer detection technologies, especially for PCa. In this work, the current state-of-the-art, challenges, and efforts made by the researchers for realization of low cost, point-of-care (POC), highly sensitive, and specific NP enhanced optical biosensing technologies for PCa detection using PSA biomarker are discussed and analyzed.
Collapse
|
5
|
Chen Y, Liu H, Jiang J, Gu C, Zhao Z, Jiang T. Immunoassay of Tumor Markers Based on Graphene Surface-Enhanced Raman Spectroscopy. ACS APPLIED BIO MATERIALS 2020; 3:8012-8022. [DOI: 10.1021/acsabm.0c01098] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Ying Chen
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, P. R. China
| | - Hongmei Liu
- Institute of Solid State Physics, Shanxi Datong University, Datong 037009, Shanxi, P. R. China
| | - Jiamin Jiang
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, P. R. China
| | - Chenjie Gu
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, P. R. China
| | - Ziqi Zhao
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, P. R. China
| | - Tao Jiang
- Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, P. R. China
| |
Collapse
|
6
|
Blanco-Formoso M, Pazos-Perez N, Alvarez-Puebla RA. Fabrication and SERS properties of complex and organized nanoparticle plasmonic clusters stable in solution. NANOSCALE 2020; 12:14948-14956. [PMID: 32643745 DOI: 10.1039/d0nr04167j] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
SERS activity can be increased by the formation of hot spots at the interparticle junctions of plasmonic nanoparticles in very close proximity, dramatically improving the enhancement factors in comparison with isolated nanoparticles. Controlling the number and geometrical architecture of hot spots, while endowing the clusters with colloidal stability, results in feasible optical sensors, able to provide quantitative SERS responses. Here, we review the approaches proposed to date to produce colloidal stable clusters, focusing on the control of the coordination number of nanoparticle assemblies and interparticle gaps. Clusters of spherical nanoparticles of the same size and rods of the same size are described to subsequently outline core-satellite constructs of nanoparticles of different sizes. Besides, purification processes for nanoparticle clusters are revised to provide efficient production in high yields.
Collapse
Affiliation(s)
- Maria Blanco-Formoso
- Department of Physical Chemistry, Universitat Rovira i Virgili, 43007 Tarragona, Spain.
| | - Nicolas Pazos-Perez
- Department of Physical Chemistry, Universitat Rovira i Virgili, 43007 Tarragona, Spain.
| | - Ramon A Alvarez-Puebla
- Department of Physical Chemistry, Universitat Rovira i Virgili, 43007 Tarragona, Spain. and ICREA, Passeig Lluis Companys 23, 08010 Barcelona, Spain
| |
Collapse
|
7
|
Zou S, Ma L, Li J, Liu Y, Zhao D, Zhang Z. Ag Nanorods-Based Surface-Enhanced Raman Scattering: Synthesis, Quantitative Analysis Strategies, and Applications. Front Chem 2019; 7:376. [PMID: 31214564 PMCID: PMC6558050 DOI: 10.3389/fchem.2019.00376] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Accepted: 05/08/2019] [Indexed: 12/16/2022] Open
Abstract
Surface-Enhanced Raman Scattering (SERS) is a powerful technology that provides abundant chemical fingerprint information with advantages of high sensitivity and time-saving. Advancements in SERS substrates fabrication allow Ag nanorods (AgNRs) possess superior sensitivity, high uniformity, and excellent reproducibility. To further promote AgNRs as a promising SERS substrate candidate to a broader application scope, oxides are integrated with AgNRs by virtue of their unique properties which endow the AgNRs-oxide hybrid with high stability and recyclability. Aside from SERS substrates fabrication, significant developments in quantitative analysis strategies offer enormous approaches to minimize influences resulted from variations of measuring conditions and to provide the reasonable data analysis. In this review, we discuss various fabrication approaches for AgNRs and AgNRs-oxide hybrids to achieve efficient SERS platforms. Then, we introduce three types of strategies which are commonly employed in chemical quantitative analysis to reach a reliable result. Further, we highlight SERS applications including food safety, environment safety, biosensing, and vapor sensing, demonstrating the potential of SERS as a powerful and promising technique. Finally, we conclude with the current challenges and future prospects toward efficient SERS manipulations for broader real-world applications.
Collapse
Affiliation(s)
- Sumeng Zou
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, China
| | - Lingwei Ma
- Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing, China
| | - Jianghao Li
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, China
| | - Yuehua Liu
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, China
| | - Dongliang Zhao
- Department of Functional Material Research, Central Iron and Steel Research Institute, Beijing, China
| | - Zhengjun Zhang
- Key Laboratory of Advanced Materials (MOE), School of Materials Science and Engineering, Tsinghua University, Beijing, China
| |
Collapse
|
8
|
Damborska D, Bertok T, Dosekova E, Holazova A, Lorencova L, Kasak P, Tkac J. Nanomaterial-based biosensors for detection of prostate specific antigen. Mikrochim Acta 2017; 184:3049-3067. [PMID: 29109592 PMCID: PMC5669453 DOI: 10.1007/s00604-017-2410-1] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Screening serum for the presence of prostate specific antigen (PSA) belongs to the most common approach for the detection of prostate cancer. This review (with 156 refs.) addresses recent developments in PSA detection based on the use of various kinds of nanomaterials. It starts with an introduction into the field, the significance of testing for PSA, and on current limitations. A first main section treats electrochemical biosensors for PSA, with subsections on methods based on the use of gold electrodes, graphene or graphene-oxide, carbon nanotubes, hybrid nanoparticles, and other types of nanoparticles. It also covers electrochemical methods based on the enzyme-like activity of PSA, on DNA-, aptamer- and biofuel cell-based methods, and on the detection of PSA via its glycan part. The next main section covers optical biosensors, with subsections on methods making use of surface plasmon resonance (SPR), localized SPR and plasmonic ELISA-like schemes. This is followed by subsections on methods based on the use of fiber optics, fluorescence, chemiluminescence, Raman scattering and SERS, electrochemiluminescence and cantilever-based methods. The most sensitive biosensors are the electrochemical ones, with lowest limits of detection (down to attomolar concentrations), followed by mass cantilever sensing and electrochemilumenescent strategies. Optical biosensors show lower performance, but are still more sensitive compared to standard ELISA. The most commonly applied nanomaterials are metal and carbon-based ones and their hybrid composites used for different amplification strategies. The most attractive sensing schemes are summarized in a Table. The review ends with a section on conclusions and perspectives.
Collapse
Affiliation(s)
- Dominika Damborska
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Tomas Bertok
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Erika Dosekova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Alena Holazova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Lenka Lorencova
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| | - Peter Kasak
- Center for Advanced Materials, Qatar University, P.O. Box 2713, Doha, Qatar
| | - Jan Tkac
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 38 Bratislava, Slovakia
| |
Collapse
|
9
|
Blanco-Covián L, Montes-García V, Girard A, Fernández-Abedul MT, Pérez-Juste J, Pastoriza-Santos I, Faulds K, Graham D, Blanco-López MC. Au@Ag SERRS tags coupled to a lateral flow immunoassay for the sensitive detection of pneumolysin. NANOSCALE 2017; 9:2051-2058. [PMID: 28112761 DOI: 10.1039/c6nr08432j] [Citation(s) in RCA: 70] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Establishing a definitive diagnosis of pneumonia using conventional tests is difficult and expensive. Lateral flow immunoassays (LFIAs) are an advantageous point of care (POC) test option, but they have some limitations in terms of detection and quantification. In this work we have developed a lateral flow immunoassay for the ultrasensitive detection of penumolysin employing plasmonic Surface-Enhanced Resonance Raman Scattering (SERRS) tag as labelled probe. The combination of Au@Ag core-shell nanoparticles as plasmonic platform and Rhodamine B Isothiocyanate as Raman reporter has allowed us to fabricate a SERRS tag with high efficiency and reliability. The limit of detection of the SERRS-based LFIA was 1 pg mL-1. This could be a strong foundation for a pneumonia diagnosis test based on pneumolysin detection.
Collapse
Affiliation(s)
- Lucía Blanco-Covián
- Departamento de Química Física y Analítica, Universidad de Oviedo, 33006 Oviedo, Spain.
| | | | - Alexandre Girard
- Centre for Molecular Nanometrology, Department of Pure and Applied Chemistry, WestCHEM, University of Strathclyde, Glasgow G1 1RD, UK
| | | | - Jorge Pérez-Juste
- Departamento de Química Física and CINBIO, Universidade de Vigo, 36310 Vigo, Spain.
| | | | - Karen Faulds
- Centre for Molecular Nanometrology, Department of Pure and Applied Chemistry, WestCHEM, University of Strathclyde, Glasgow G1 1RD, UK
| | - Duncan Graham
- Centre for Molecular Nanometrology, Department of Pure and Applied Chemistry, WestCHEM, University of Strathclyde, Glasgow G1 1RD, UK
| | - M Carmen Blanco-López
- Departamento de Química Física y Analítica, Universidad de Oviedo, 33006 Oviedo, Spain.
| |
Collapse
|
10
|
Khlebtsov B, Pylaev T, Khanadeev V, Bratashov D, Khlebtsov N. Quantitative and multiplex dot-immunoassay using gap-enhanced Raman tags. RSC Adv 2017. [DOI: 10.1039/c7ra08113h] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
A highly specific, quantitative, and multiplex dot immunoassay has been developed. The immunoassay utilizes functionalized plasmonic gap-enhanced Raman tags (GERTs) as labels and nitrocellulose membrane as a substrate.
Collapse
Affiliation(s)
- Boris Khlebtsov
- Institute of Biochemistry and Physiology of Plants and Microorganisms
- Russian Academy of Sciences
- Saratov 410049
- Russia
| | - Timophey Pylaev
- Institute of Biochemistry and Physiology of Plants and Microorganisms
- Russian Academy of Sciences
- Saratov 410049
- Russia
| | - Vitaly Khanadeev
- Institute of Biochemistry and Physiology of Plants and Microorganisms
- Russian Academy of Sciences
- Saratov 410049
- Russia
| | | | - Nikolai Khlebtsov
- Institute of Biochemistry and Physiology of Plants and Microorganisms
- Russian Academy of Sciences
- Saratov 410049
- Russia
- National Research Saratov State University
| |
Collapse
|
11
|
Affiliation(s)
- Xiuli Fu
- School
of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong 264005, China
| | - Lingxin Chen
- School
of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong 264005, China
- Key
Laboratory of Coastal Environmental Processes and Ecological Remediation,
Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, Shandong 264003, China
| | - Jaebum Choo
- Department
of Bionanotechnology, Hanyang University, Ansan, Gyeonggi 426-791, South Korea
| |
Collapse
|
12
|
Chao J, Cao W, Su S, Weng L, Song S, Fan C, Wang L. Nanostructure-based surface-enhanced Raman scattering biosensors for nucleic acids and proteins. J Mater Chem B 2016; 4:1757-1769. [PMID: 32263053 DOI: 10.1039/c5tb02135a] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Detection of nucleic acid and protein targets related to human health and safety has attracted widespread attention. Surface-enhanced Raman scattering (SERS) is a powerful tool for biomarker detection because of its ultrahigh detection sensitivity and unique fingerprinting spectra. In this review, we first introduce the development of nanostructure-based SERS-active substrates and SERS nanotags, which greatly influence the performance of SERS biosensors. We then focus on recent advances in SERS biosensors for DNA, microRNA and protein determination, including label-free, labeled and multiplex analyses as well as in vivo imaging. Finally, the prospects and challenges of such nanostructure-based SERS biosensors are discussed.
Collapse
Affiliation(s)
- Jie Chao
- Key Laboratory for Organic Electronics and Information Displays & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts & Telecommunications, 9 Wenyuan Road, Nanjing 210023, China.
| | | | | | | | | | | | | |
Collapse
|
13
|
Pihíková D, Belicky Š, Kasák P, Bertok T, Tkac J. Sensitive detection and glycoprofiling of a prostate specific antigen using impedimetric assays. Analyst 2015; 141:1044-51. [PMID: 26647853 DOI: 10.1039/c5an02322j] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
This study presents a proof-of-concept for the development of an impedimetric biosensor for ultra-sensitive glycoprofiling of prostate specific antigen (PSA). The biosensor exhibits three unique characteristics: (1) analysis of PSA with limit of detection (LOD) down to 4 aM; (2) analysis of the glycan part of PSA with LOD down to 4 aM level and; (3) both assays (i.e., PSA quantification and PSA glycoprofiling) can be performed on the same interface due to label-free analysis.
Collapse
Affiliation(s)
- D Pihíková
- Department of Glycobiotechnology, Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, Bratislava, 845 38, Slovak Republic.
| | | | | | | | | |
Collapse
|
14
|
Fahimi-Kashani N, Shadabipour P, Hormozi-Nezhad MR. Colorimetric detection of glutathione based on transverse overgrowth of high aspect ratio gold nanorods investigated by MCR-ALS. RSC Adv 2015. [DOI: 10.1039/c5ra14784k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
In this paper, we present a simple platform for colorimetric detection of glutathione using gold nanorods (AR ∼ 6.5 ± 0.2) as a plasmonic sensor.
Collapse
Affiliation(s)
| | - Parisa Shadabipour
- Department of Chemistry
- Sharif University of Technology
- Tehran 11155-9516
- Iran
| | - M. Reza Hormozi-Nezhad
- Department of Chemistry
- Sharif University of Technology
- Tehran 11155-9516
- Iran
- Institute of Nanoscience and Nanotechnology
| |
Collapse
|