1
|
Ayazi Z, Farshineh Saei S, Pashayi Sarnaghi S. A novel self-supportive thin film based on graphene oxide reinforced chitosan nano-biocomposite for thin film microextraction of fluoxetine in biological and environmental samples. J Pharm Biomed Anal 2023; 236:115678. [PMID: 37672904 DOI: 10.1016/j.jpba.2023.115678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 08/15/2023] [Accepted: 08/22/2023] [Indexed: 09/08/2023]
Abstract
In this research, for the first time, graphene oxide doped chitosan (GO/CS) nano-biocomposite (NBC) is designed and prepared as a novel self-supportive thin layer for thin film microextraction (TFME) of fluoxetine (FLX) followed by determination applying HPLC-UV-Vis. The properties of the prepared self-supportive thin film were characterized applying ATR-FTIR, FESEM, and XRD techniques. The extraction capability of GO/CS NBC toward FLX has been evaluated, and the obtained results revealed that incorporation of GO into CS has led to higher extraction efficiency in comparison to the CS thin film. After optimizing the effective factors on the extraction efficiency, the figures of merit for the developed method have been evaluated for determination of FLX in various samples. Accordingly, the method's linearity is in the range of 0.4-800 ng mL-1 (R2 = 0.996), 4-1000 ng mL-1 (R2 = 0.994), 4-1000 ng mL-1 (R2 = 0.990), and 6-1000 ng mL-1 (R2 = 0.993) for deionized water, wastewater, urine and plasma samples, respectively. The limits of detection based on 3 S/N definition was 0.1, 1, 1 and 1.6 ng mL-1 for deionized water, wastewater, urine, and plasma samples, respectively. The repeatability of the developed method has been investigated in the term of intra-day, inter-day and inter-thin film precision and RSD% values for six replicate experiments were obtained 8.6%, 8.4% and 5.7%, respectively. The accuracy of the developed method has been investigated by extraction of FLX from spiked wastewater, plasma and urine samples and the relative recoveries of 104.4%, 87.3% and 82.4% have been resulted, respectively.
Collapse
Affiliation(s)
- Zahra Ayazi
- Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, P.O. Box 53714- l6l, Tabriz, Iran; Molecular Science and Engineering Research Group (MSERG), Azarbaijan Shahid Madani University, Tabriz, Iran.
| | - Sima Farshineh Saei
- Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, P.O. Box 53714- l6l, Tabriz, Iran
| | - Samira Pashayi Sarnaghi
- Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, P.O. Box 53714- l6l, Tabriz, Iran
| |
Collapse
|
2
|
Liu YJ, Zhang Y, Bian Y, Sang Q, Ma J, Li PY, Zhang JH, Feng XS. The environmental sources of benzophenones: Distribution, pretreatment, analysis and removal techniques. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2023; 267:115650. [PMID: 37939555 DOI: 10.1016/j.ecoenv.2023.115650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 10/21/2023] [Accepted: 10/27/2023] [Indexed: 11/10/2023]
Abstract
Benzophenones (BPs) have wide practical applications in real human life due to its presence in personal care products, UV-filters, drugs, food packaging bags, etc. It enters the wastewater by daily routine activities such as showering, impacting the whole aquatic system, then posing a threat to human health. Due to this fact, the monitoring and removal of BPs in the environment is quite important. In the past decade, various novel analytical and removal techniques have been developed for the determination of BPs in environmental samples including wastewater, municipal landfill leachate, sewage sludge, and aquatic plants. This review provides a critical summary and comparison of the available cutting-edge pretreatment, determination and removal techniques of BPs in environment. It also focuses on novel materials and techniques in keeping with the concept of "green chemistry", and describes on challenges associated with the analysis of BPs, removal technologies, suggesting future development strategies.
Collapse
Affiliation(s)
- Ya-Jie Liu
- School of Pharmacy, China Medical University, Shenyang 110122, China
| | - Yuan Zhang
- School of Pharmacy, China Medical University, Shenyang 110122, China
| | - Yu Bian
- School of Pharmacy, China Medical University, Shenyang 110122, China
| | - Qi Sang
- Hematology Laboratory, Shengjing Hospital of China Medical University, Shenyang 110022, China
| | - Jing Ma
- School of Pharmacy, China Medical University, Shenyang 110122, China
| | - Peng-Yun Li
- National Engineering Research Center for Strategic Drugs, Beijing Institute of Pharmacology and Toxicology Institution, Beijing 100850, China
| | - Ji-Hong Zhang
- Hematology Laboratory, Shengjing Hospital of China Medical University, Shenyang 110022, China.
| | - Xue-Song Feng
- School of Pharmacy, China Medical University, Shenyang 110122, China.
| |
Collapse
|
3
|
Osooli P, Yamini Y, Tabibpour M, Moosavi NS. Functionalized carbon nanotube-polyaniline composite coating for on-line microextraction on a screw coupled with high performance liquid chromatography to determine opium alkaloids. Mikrochim Acta 2023; 190:464. [PMID: 37947885 DOI: 10.1007/s00604-023-06045-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 10/17/2023] [Indexed: 11/12/2023]
Abstract
A novel and efficient on-line microextraction on a screw coupled with high-performance liquid chromatography with an ultraviolet-visible detector was developed to extract and determine trace quantities of five opium alkaloids. All detections of the analytes were achieved at 210 nm. The surface of the screw grooves was electrochemically coated with the carbon nanotubes-COOH/polyaniline composite. The surface characterization was assessed by Fourier transform infrared spectroscopy and field emission scanning electron microscopy. The prepared screw was inserted into a cartridge of a guard column, and then the constructed microextraction on a screw device was placed in the loop of a six-port HPLC injection valve. The parameters affecting the extraction efficiency of the analytes were optimized using the one variable-at-a-time method. The effective parameters for the extraction efficiency of the analytes, including sample volume, extraction time, sampling flow rate, desorption solvent type, ionic strength, and pH were investigated and optimized. Under optimal conditions, the detection limits were 3-10 μg L-1, and the linear dynamic ranges were 10-2000 μg L-1 with a coefficient of determination greater than 0.9940. The inter-day and intra-day (n = 3) relative standard deviations were less than 7% and 5%, respectively. The proposed method was simple and reproducible, with an acceptable relative recovery (90-108%) for determining opium alkaloids in water and urine samples.
Collapse
Affiliation(s)
- Payam Osooli
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
| | - Mahmoud Tabibpour
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Negar Sabahi Moosavi
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| |
Collapse
|
4
|
Rahmani S, Aibaghi B. Synthesis and application of new silver and sulfur decorated S-doped reduced graphene oxide in ultra-trace analysis of pesticides by ion mobility spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3493-3500. [PMID: 36004576 DOI: 10.1039/d2ay00852a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In this research study, a novel, facile, and affordable method is presented for the synthesis of a Ag/S/S-RGO nanocomposite. The resulting new nanocomposite was identified by FT-IR, XRD, FESEM, XPS, BET and EDX and employed as a rapid and effective adsorbent with acceptable absorption capacity for the analysis of various pesticides by dispersive solid-phase microextraction combined with ion mobility spectrometry. The main experimental parameters of the method were optimized such as the type of desorption solvent, pH of the sample solution, type of buffer, amount of the sorbent (Ag/S/S-RGO), sorption/desorption time, etc. Under the optimized conditions, linear dynamic ranges of 0.5-110.0, 1.0-110.0, and 0.8-90.0 ng mL-1 were achieved, with limits of detection of 0.25, 0.35, and 0.25 ng mL-1 for simazine, alachlor, and haloxyfop, respectively. The relative standard deviations (RSD%) were obtained as <5.0%. Eventually, the method was utilized for the simultaneous determination of simazine, alachlor, and haloxyfop in environmental and agricultural samples with recoveries between 95.0 and 104.6%.
Collapse
Affiliation(s)
- Sedigheh Rahmani
- School of Chemistry, Damghan University, Damghan 3671641167, Iran.
| | - Behzad Aibaghi
- School of Chemistry, Damghan University, Damghan 3671641167, Iran.
| |
Collapse
|
5
|
Preconcentration and determination of four antibiotics in biological samples using nanofluid-assisted magnetic dispersive micro-solid-phase extraction coupled with high-performance liquid chromatography. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-021-01903-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
Application of ZnS/S/S-RGO three-component nanocomposites in dispersive solid-phase microextraction coupled with ion mobility spectrometry for ultra-trace determination of multiclass pesticides. Mikrochim Acta 2021; 189:9. [PMID: 34862930 DOI: 10.1007/s00604-021-05116-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 11/19/2021] [Indexed: 01/21/2023]
Abstract
A fast, effective, and sensitive dispersive solid-phase microextraction method coupled with ion mobility spectrometry for the simultaneous determination of bendiocarb, butachlor, and diazinon was developed using zinc sulfide/sulfur/sulfur-doped reduced graphene oxide (ZnS/S/S-RGO) nanocomposites. ZnS/S/S-RGO three-component nanocomposites were synthesized through a single-step solvothermal procedure, and their properties were characterized by FT-IR, XRD, X-ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), and energy-dispersive x-ray spectroscopy (EDX). The influence of different parameters was optimized on the efficiency of the extraction including the type and the volume of desorption solvent, pH, type and the volume of buffer, the amount of absorbent, sorption and desorption times. Under the optimal conditions, linear ranges were achieved 0.8-110, 1.0-110, and 0.5-100 ng mL-1 with detection limits of 0.32±0.01, 0.40±0.02, and 0.27±0.02 ng mL-1 for bendiocarb, butachlor, and diazinon, respectively. The method was employed for the ultra-trace determination of the three pesticides in water, rice, and soil samples with acceptable recovery values within the range 96.6±4.8-104.4±6.4%.
Collapse
|
7
|
Ayazi Z, Shekari Esfahlan F. A monolithic mixed matrix membrane based on silver nanoparticle/nylon‐6 nanocomposite: A novel coating for stir bar sorptive extraction of organophosphorus pesticides. SEPARATION SCIENCE PLUS 2021. [DOI: 10.1002/sscp.202000108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Zahra Ayazi
- Department of Chemistry, Faculty of Sciences Azarbaijan Shahid Madani University Tabriz Iran
| | | |
Collapse
|
8
|
Mohammadi P, Masrournia M, Es'haghi Z, Pordel M. Determination of four antiepileptic drugs with solvent assisted dispersive solid phase microextraction – Gas chromatography–mass spectrometry in human urine samples. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105542] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
9
|
Dozein SV, Masrournia M, Es’haghi Z, Bozorgmehr MR. Development of a New Magnetic Dispersive Solid-Phase Microextraction Coupled with GC-MS for the Determination of Five Organophosphorus Pesticides from Vegetable Samples. FOOD ANAL METHOD 2020. [DOI: 10.1007/s12161-020-01906-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
10
|
Ghorbani M, Aghamohammadhassan M, Ghorbani H, Zabihi A. Trends in sorbent development for dispersive micro-solid phase extraction. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105250] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
11
|
Beiranvand M, Ghiasvand A. An ultrasound-assisted pressure-regulated solid-phase microextraction setup for fast and sensitive analysis of volatile pollutants in contaminated soil. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:36306-36315. [PMID: 32556985 DOI: 10.1007/s11356-020-09620-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 06/04/2020] [Indexed: 06/11/2023]
Abstract
Release of analytes from their native matrix and diffusion into the gas phase is the rate-limiting step for the sampling of volatiles in complex solid samples. This limitation is more serious in the solvent-less and solvent-free microextraction sampling strategies. In this research, a three-stage reinforced sampling strategy including high-pressure/sonication/low-pressure was introduced for fast and efficient release of analytes in soil samples. For this purpose, a novel ultrasound-assisted pressure-regulated solid-phase microextraction (UA-PR-SPME) device was developed. It was coupled with gas chromatography-flame ionization detection (GC-FID) and carried out for the determination of benzene, toluene, ethylbenzene, and xylenes (BTEX, as the model analytes) in complex solid samples. Graphene oxide/3-aminopropyltriethoxysilane (GO-APTES) nanocomposite was synthesized and used as the SPME fiber coating. Under optimal conditions, the limits of detection (LODs) were obtained 0.1-0.4 ng/g. The calibration curves were linear over the range of 2.4-5000 ng/g. Relative standard deviations (RSDs%) were calculated 5.1-7.0% (n = 6). The developed technique was employed for the analysis of BTEX in contaminated soil samples.
Collapse
Affiliation(s)
| | - Alireza Ghiasvand
- Department of Chemistry, Lorestan University, Khoramabad, Iran.
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia.
| |
Collapse
|
12
|
Figueira JA, Porto-Figueira P, Pereira JA, Câmara JS. A comprehensive methodology based on NTME/GC-MS data and chemometric tools for lemons discrimination according to geographical origin. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104933] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
13
|
Jahed FS, Hamidi S, Galehassadi M. Dispersive Micro-Solid Phase Extraction for Sensitive Determination of Methotrexate from Human Saliva Followed by Spectrophotometric Method. Asian Pac J Cancer Prev 2020; 21:1531-1538. [PMID: 32592345 PMCID: PMC7568869 DOI: 10.31557/apjcp.2020.21.6.1531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2018] [Indexed: 11/25/2022] Open
Abstract
For biological assessing of hospital personnel occupationally exposed to antineoplastic drugs, highly sensitive and accurate methods are required. Methotrexate (MTX) is an anticancer agent that is widely used in a variety of human cancers. For the first time, dispersive-micro solid phase extraction (D-µ-SPE) has been applied for determination of low levels of MTX in saliva samples. The method is based on rapid extraction of MTX using graphene oxide adsorbent. The sample preparation time is decreased by the fact that the adsorbent dispersed in the sample solution and extraction equilibrium can be reached very fast. This significant feature which obtained with this method is of key interest for routine trace laboratory analysis. The influence of different variables on D-µ-SPE was investigated. Under optimum conditions, the calibration graph was linear over the range of 10-1000 ng/ml. The relative standard deviations are better than 9.0%. The proposed method was successfully applied for the determination of MTX in patient samples.
Collapse
Affiliation(s)
- Fatemeh Soghra Jahed
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
| | - Samin Hamidi
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
| | - Mohammad Galehassadi
- Department of Organic Chemistry, Azarbaijan Shahid Madani University, Tabriz, Iran
| |
Collapse
|
14
|
Abdolmohammad-Zadeh H, Ayazi Z, Hosseinzadeh S. Application of Co3O4 nanoparticles as an efficient nano-sorbent for solid-phase extraction of zinc(II) ions. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104268] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
15
|
Jalili V, Barkhordari A, Ghiasvand A. New extraction media in microextraction techniques. A review of reviews. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104386] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
16
|
|
17
|
Magnetic Polyamide Nanocomposites for the Microextraction of Benzophenones from Water Samples. MOLECULES (BASEL, SWITZERLAND) 2019; 24:molecules24050953. [PMID: 30857139 PMCID: PMC6429122 DOI: 10.3390/molecules24050953] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 02/18/2019] [Accepted: 03/01/2019] [Indexed: 11/30/2022]
Abstract
In this article, the influence of the monomers on the extraction efficiency and the effect of the addition of surfactants during the synthesis have also been considered. The sorption capacity of the resulting nanocomposites has been evaluated, in the dispersive micro-solid phase extraction format, by determining that of six benzophenones in water using ultra performance liquid chromatography (UPLC) combined with photodiode array detection. Under the optimum conditions, the limits of detection were in the range of 0.5–4.3 ng/mL and the repeatability, expressed as the relative standard deviation (RSD), varied between 1.5% and 5.6%. The proposed method has been applied for the analysis of real water samples, providing relative recoveries in the interval of 84–105%
Collapse
|
18
|
Hamidi S, Azami A, Mehdizadeh Aghdam E. A novel mixed hemimicelles dispersive micro-solid phase extraction using ionic liquid functionalized magnetic graphene oxide/polypyrrole for extraction and pre-concentration of methotrexate from urine samples followed by the spectrophotometric method. Clin Chim Acta 2018; 488:179-188. [PMID: 30419220 DOI: 10.1016/j.cca.2018.11.006] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 10/31/2018] [Accepted: 11/02/2018] [Indexed: 11/30/2022]
Abstract
Methotrexate (MTX) is an anticancer drug that is widely used in a variety of cancers including primary central nervous system lymphoma. It is also administrated in the treatment of some autoimmune diseases. A simple, accurate, sensitive, and precise mixed hemimicelles dispersive micro-solid phase extraction was proposed for MTX quantification in human urine samples. MTX was quantified by spectrophotometer after dispersive micro-solid phase extraction using ionic liquid functionalized magnetic graphene oxide/polypyrrole. Interactions of adsorbent and MTX were modeled by molecular docking and the interaction energy was predicted to be -8.35 kcal/mol. A larger absolute value of binding energy represents larger adsorption strength, indicating that graphene oxide nanosheets could perform higher adsorption strength toward MTX. The concentrations of MTX were proportional to analytical response in amounts ranging from 10 to 1000 ng/mL with a good correlation (R2 = 0.99). Inter- and intra-day precisions and accuracies were within the acceptable limit according to FDA guideline (15% for biological determination). The recoveries were ranging from 89 to 93% and the method was specific for routine analysis of MTX. This protocol was applied to the urine of two patients under MTX therapy received an intravenous administration of 1 mg/kg/dose of MTX with acute lymphoblastic leukemia. The accuracy of the method was confirmed by HPLC measurements.
Collapse
Affiliation(s)
- Samin Hamidi
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz 51664, Iran.
| | - Ayda Azami
- Drug Applied Research Center, Tabriz University o f Medical Sciences, Tabriz, Iran
| | - Elnaz Mehdizadeh Aghdam
- Research Center of Molecular Medicine, Tabriz University of Medical Sciences, Tabriz, Iran; Department of Pharmaceutical Biotechnology, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
19
|
Tahmasebi E. Adsorption efficiency enhancing of electrospun polycaprolactone nanofibers towards acidic polar drugs through the incorporation of a composite of graphene oxide nanosheets and Al 30 polyoxocations: a comparative study. Analyst 2018; 143:4684-4698. [PMID: 30179241 DOI: 10.1039/c8an01066h] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The main objective of this study focuses on exploration of the feasibility of Al30 polyoxocations for preparation of a novel sorbent material for a solid-phase extraction (SPE) method by selective adsorption and extraction of a class of compounds considering the type of interactions involved in the adsorption process. Accordingly, first Al30 polyoxocations were synthesized and their composite was prepared with graphene oxide (GO) nanosheets as a suitable substrate to be introduced as a SPE sorbent material. Then, the prepared composite was incorporated into polycaprolactone (PCL) nanofibers via electrospinning to present an alternative sorbent for SPE-based on a GO/Al30 nanocomposite (GO/Al30 NC) creating no need for filtering or centrifuging steps. Intercalation of Al30 polyoxocations into the GO layers and the incorporation of GO/Al30 NC into PCL nanofibers was successfully confirmed through FE-SEM, TEM, EDX, XRD, BET, TGA, IR spectroscopy, and zeta potential determination. For investigating the types of probable interactions involved in the adsorption process of different compounds on the proposed sorbents, four statin drugs, cholesterol-lowering agents with various polarity and ionization properties, were selected as model analytes. Factors affecting the extraction efficiency of dispersive SPE and immersed SPE methods using GO/Al30 NC and GO/Al30 NC-PCL nanofibers, respectively, were investigated and optimized. Under optimal conditions, acceptable analytical figures of merit were obtained for both SPE methods. A comparison of extraction efficiencies of the target drugs by the two proposed sorbents, as well as GO nanosheets and PCL nanofibers, was accomplished to study the types of interactions as well as the adsorption mechanism. The results revealed that GO/Al30 NC, having many polar and anion exchange sites caused by Al30 polyoxocations, is a good selective sorbent for acidic polar compounds which their extraction by nonpolar sorbents is not desirable. Additionally, GO/Al30 NC-PCL nanofibers exhibited extraction capability for a wide range of compounds from acidic polar to nonpolar and nonionizable ones.
Collapse
Affiliation(s)
- Elham Tahmasebi
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), P.O. Box 45195-1159, Zanjan, Iran.
| |
Collapse
|
20
|
On-Line Fabric Disk Sorptive Extraction via a Flow Preconcentration Platform Coupled with Atomic Absorption Spectrometry for the Determination of Essential and Toxic Elements in Biological Samples. SEPARATIONS 2018. [DOI: 10.3390/separations5030034] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
|
21
|
Wang G, Morrin A, Li M, Liu N, Luo X. Nanomaterial-doped conducting polymers for electrochemical sensors and biosensors. J Mater Chem B 2018; 6:4173-4190. [DOI: 10.1039/c8tb00817e] [Citation(s) in RCA: 114] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
This review summarizes recent advances in the development of electrochemical sensors and biosensors based on nanomaterial doped conducting polymers.
Collapse
Affiliation(s)
- Guixiang Wang
- Key Laboratory of Sensor Analysis of Tumor Marker
- Ministry of Education
- College of Chemistry and Molecular Engineering
- Qingdao University of Science and Technology
- Qingdao 266042
| | - Aoife Morrin
- School of Chemical Sciences
- National Centre for Sensor Research
- INSIGHT Centre for Data Analytics
- Dublin City University
- Dublin 9
| | - Mengru Li
- Key Laboratory of Sensor Analysis of Tumor Marker
- Ministry of Education
- College of Chemistry and Molecular Engineering
- Qingdao University of Science and Technology
- Qingdao 266042
| | - Nianzu Liu
- Key Laboratory of Sensor Analysis of Tumor Marker
- Ministry of Education
- College of Chemistry and Molecular Engineering
- Qingdao University of Science and Technology
- Qingdao 266042
| | - Xiliang Luo
- Key Laboratory of Sensor Analysis of Tumor Marker
- Ministry of Education
- College of Chemistry and Molecular Engineering
- Qingdao University of Science and Technology
- Qingdao 266042
| |
Collapse
|
22
|
Efficient extraction method using magnetic carbon nanotubes to analyze cocaine and benzoylecgonine in breast milk by GC/MS. Bioanalysis 2017; 9:1655-1666. [DOI: 10.4155/bio-2017-0140] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
Aim: The increasing use of cocaine (COC) during breastfeeding has led to growing concern about exposure of infants. Therefore, to study this exposure, a new method to analyze COC and benzoylecgonine in breast milk was developed. Methodology: A new extraction method was used for the first time to analyze COC and its major metabolite, benzoylecgonine, in breast milk using magnetic carbon nanotubes partially doped with nitrogen. Results: The calibration curves were linear in the range 5.0–180.0 ng ml-1. The limit of quantification was 5.0 ng ml-1. Coefficients of variation were between 3.2 and 13.9%. Recovery was between 89.6 and 99.2%. Conclusion: The proposed method is simple, efficient and suitable to determine analytes in breast milk.
Collapse
|
23
|
Kędziora K, Wasiak W. Extraction media used in needle trap devices—Progress in development and application. J Chromatogr A 2017; 1505:1-17. [DOI: 10.1016/j.chroma.2017.05.030] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 05/10/2017] [Accepted: 05/12/2017] [Indexed: 12/13/2022]
|
24
|
Adhikari BR, Schraft H, Chen A. A high-performance enzyme entrapment platform facilitated by a cationic polymer for the efficient electrochemical sensing of ethanol. Analyst 2017; 142:2595-2602. [DOI: 10.1039/c7an00594f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
An efficient enzyme entrapment approach using a cationic polymer has been demonstrated for the development of a high-performance ethanol biosensor.
Collapse
Affiliation(s)
| | - Heidi Schraft
- Department of Biology
- Lakehead University
- Thunder Bay
- Canada
| | - Aicheng Chen
- Department of Chemistry
- Lakehead University
- Thunder Bay
- Canada
| |
Collapse
|