1
|
Juraeva M, Kang DJ. Design and Mixing Analysis of a Passive Micromixer with Circulation Promoters. MICROMACHINES 2024; 15:831. [PMID: 39064343 PMCID: PMC11278850 DOI: 10.3390/mi15070831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 06/21/2024] [Accepted: 06/23/2024] [Indexed: 07/28/2024]
Abstract
A novel passive micromixer equipped with circulation promoters is proposed, and its mixing performance is simulated over a broad range of Reynolds numbers (0.1≤Re≤100). To evaluate the effectiveness of the circulation promoters, three different configurations are analyzed in terms of the degree of mixing (DOM) at the outlet and the associated pressure drop. Compared to other typical passive micromixers, the circulation promoter is shown to significantly enhance mixing performance. Among the three configurations of circulation promoters, Case 3 demonstrates the best performance, with a DOM exceeding 0.96 across the entire range of Reynolds numbers. At Re = 1, the DOM of Case 3 is 3.7 times larger than that of a modified Tesla micromixer, while maintaining a comparable pressure drop. The mixing enhancement of the present micromixer is particularly significant in the low and intermediate ranges of Reynolds numbers (Re<40). In the low range of Reynolds numbers (Re≤1), the mixing enhancement is primarily due to circulation promoters directing fluid flow from a concave wall to the opposite convex wall. In the intermediate range of Reynolds numbers (2≤Re<40), the mixing enhancement results from fluid flowing from one concave wall to another concave wall on the opposite side.
Collapse
Affiliation(s)
| | - Dong-Jin Kang
- School of Mechanical Engineering, Yeungnam University, 280 Daehak-ro, Gyoungsan 38541, Republic of Korea
| |
Collapse
|
2
|
Wu Y, Ma X, Li K, Yue Y, Zhang Z, Meng Y, Wang S. Bipolar Electrode-based Sheath-Less Focusing and Continuous Acoustic Sorting of Particles and Cells in an Integrated Microfluidic Device. Anal Chem 2024; 96:3627-3635. [PMID: 38346846 DOI: 10.1021/acs.analchem.3c05755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
Sheath-less focusing and sorting of cells or particles is an important preprocessing step in a variety of biochemical applications. Most of the previous sorting methods depend on the use of sheath flows to realize efficient cell focusing. The sheath flow dilutes the sample and requires precise flow control via additional channels. We, for the first time, reported a method of bipolar electrode (BPE)-based sheath-less focusing, switching, and tilted-angle standing surface acoustic wave-based sorting of cells and particles in continuous flow. The device consists of a piezoelectric substrate with a pair of BPEs for focusing and switching, and a pair of interdigitated transducers for cell sorting. Smaller cells experience a weak acoustic force and reach the lower outlet, whereas larger cells are subjected to a strong acoustic force such that they are propelled toward the upper outlet. We first validate the device functionality by sorting 5 and 8 μm PS beads with a high sorting efficiency. The working and deflection regions were increased by propelling the particle beam toward the bottom edge of BPE via changing the applied voltage of BPE, further improving the sorting performance with high efficiency (94%) and purity (92%). We then conducted a verification for sorting THP-1 and yeast cells, and the efficiency and purity reached 90.7 and 91.5%, respectively. This integrated device eliminates the requirement of balancing the flow of several sheath inlets and provides a robust and unique approach for cell sorting applications, showing immense promise in various applications, such as medical diagnosis, drug delivery, and personalized medicine.
Collapse
Affiliation(s)
- Yupan Wu
- School of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, PR China
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen 518000, PR China
- Yangtze River Delta Research Institute of NPU, Taicang 215400, PR China
| | - Xun Ma
- School of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, PR China
| | - Kemu Li
- School of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, PR China
| | - Yuanbo Yue
- School of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, PR China
| | - Zhexin Zhang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, PR China
| | - Yingqi Meng
- Jiading District Central Hospital Affiliated Shanghai University of Medicine and Health Sciences, Shanghai 201800, PR China
| | - Shaoxi Wang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, PR China
| |
Collapse
|
3
|
Wang S, Zhang Z, Ma X, Yue Y, Li K, Meng Y, Wu Y. Bidirectional and Stepwise Rotation of Cells and Particles Using Induced Charge Electroosmosis Vortexes. BIOSENSORS 2024; 14:112. [PMID: 38534219 PMCID: PMC10968096 DOI: 10.3390/bios14030112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 02/08/2024] [Accepted: 02/18/2024] [Indexed: 03/28/2024]
Abstract
The rotation of cells is of significant importance in various applications including bioimaging, biophysical analysis and microsurgery. Current methods usually require complicated fabrication processes. Herein, we proposed an induced charged electroosmosis (ICEO) based on a chip manipulation method for rotating cells. Under an AC electric field, symmetric ICEO flow microvortexes formed above the electrode surface can be used to trap and rotate cells. We have discussed the impact of ICEO and dielectrophoresis (DEP) under the experimental conditions. The capabilities of our method have been tested by investigating the precise rotation of yeast cells and K562 cells in a controllable manner. By adjusting the position of cells, the rotation direction can be changed based on the asymmetric ICEO microvortexes via applying a gate voltage to the gate electrode. Additionally, by applying a pulsed signal instead of a continuous signal, we can also precisely and flexibly rotate cells in a stepwise way. Our ICEO-based rotational manipulation method is an easy to use, biocompatible and low-cost technique, allowing rotation regardless of optical, magnetic or acoustic properties of the sample.
Collapse
Affiliation(s)
- Shaoxi Wang
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Zhexin Zhang
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau, China
- Faculty of Science and Technology, University of Macau, Macau, China
| | - Xun Ma
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Yuanbo Yue
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Kemu Li
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Yingqi Meng
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
| | - Yupan Wu
- School of Microelectronics, Northwestern Polytechnical University, Xi’an 710072, China; (S.W.); (Z.Z.); (X.M.); (K.L.); (Y.M.)
- Research & Development Institute, Northwestern Polytechnical University, Shenzhen 518000, China
- Yangtze River Delta Research Institute, Northwestern Polytechnical University, Taicang 215400, China
| |
Collapse
|
4
|
Wu Y, Yue Y, Zhang H, Ma X, Zhang Z, Li K, Meng Y, Wang S, Wang X, Huang W. Three-dimensional rotation of deformable cells at a bipolar electrode array using a rotating electric field. LAB ON A CHIP 2024; 24:933-945. [PMID: 38273814 DOI: 10.1039/d3lc00882g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Three-dimensional rotation of cells is imperative in a variety of applications such as biology, medicine, and chemistry. We report for the first time a versatile approach for executing controllable 3D rotation of cells or particles at a bipolar electrode (BPE) array using a rotating electric field. The versatility of this method is demonstrated by 3D rotating various cells including yeast cells and K562 cells and the cells can be rotated to a desired orientation and immobilized for further operations. Our results demonstrate how electrorotation torque, induced charge electroosmosis (ICEO) flow and dielectrophoresis can be exerted on certain cells for modulating the rotation axis, speed, and direction. ICEO-based out-of-plane rotation is capable of rotating various cells in a vertical plane regardless of their shape and size. It can realize cell orientation by rotating cells toward a specific angle and enable cell rotation by steadily rotating multiple cells at a controllable speed. The rotation spectrum for in-plane rotation is further used to extract the cellular dielectric properties. This work offers a flexible method for controllable, contactless and precise rotation of different cells or particles, offering a rapid, high-throughput, and nondestructive rotation method for cell analysis and drug discovery.
Collapse
Affiliation(s)
- Yupan Wu
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
- Frontiers Science Center for Flexible Electronics (FSCFE) & Shaanxi Institute of Flexible Electronics (SIFE), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an, 710072, China.
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, 518000, PR China
- Yangtze River Delta Research Institute of NPU, Taicang, 215400, PR China
| | - Yuanbo Yue
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Haohao Zhang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Xun Ma
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Zhexin Zhang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Kemu Li
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Yingqi Meng
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Shaoxi Wang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Xuewen Wang
- Frontiers Science Center for Flexible Electronics (FSCFE) & Shaanxi Institute of Flexible Electronics (SIFE), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an, 710072, China.
| | - Wei Huang
- Frontiers Science Center for Flexible Electronics (FSCFE) & Shaanxi Institute of Flexible Electronics (SIFE), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an, 710072, China.
| |
Collapse
|
5
|
Wu Y, Yue Y, Zhang H, Ma X, Li K, Zeng W, Wang S, Meng Y. Label free and high-throughput discrimination of cells at a bipolar electrode array using the AC electrodynamics. Anal Chim Acta 2023; 1278:341701. [PMID: 37709447 DOI: 10.1016/j.aca.2023.341701] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 08/07/2023] [Accepted: 08/08/2023] [Indexed: 09/16/2023]
Abstract
BACKGROUND Cell characterization and manipulation play an important role in biological and medical applications. Cell viability evaluation is of significant importance for cell toxicology assay, dose test of anticancer drugs, and other biochemical stimulations. The electrical properties of cells change when cells transform from healthy to a pathological state. Current methods for evaluating cell viability usually requires a complicated chip and the throughput is limited. RESULTS In this paper, a bipolar electrode (BPE) array based microfluidic device for assessing cell viability is exploited using AC electrodynamics. The viability of various cells including yeast cells and K562 cells, can be evaluated by analyzing the electro-rotation (ROT) speed and direction of cells, as well as the dielectrophoresis (DEP) responses of cells. Firstly, the cell viability can be identified by the position of the cell captured on the BPE electrode in terms of DEP force. Besides, cell viability can also be evaluated based on both the cell rotation speed and direction using ROT. Under the action of travelling wave dielectric electrophoresis force, the cell viability can also be distinguished by the rotational motion of cells on bipolar electrode edges. SIGNIFICANCE This study demonstrates the utility of BPEs to enable scalable and high-throughput AC electrodynamics platforms by imparting a flexibility in chip design that is unparalleled by using traditional electrodes. By using BPEs, our proposed new technique owns wide application for cell characterization and viability assessment in situ detection and analysis.
Collapse
Affiliation(s)
- Yupan Wu
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China; Research & Development Institute of Northwestern Polytechnical University in Shenzhen, 518000, PR China; Yangtze River Delta Research Institute of NPU, Taicang, 215400, PR China.
| | - Yuanbo Yue
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Haohao Zhang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Xun Ma
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Kemu Li
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China
| | - Wen Zeng
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, PR China
| | - Shaoxi Wang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China.
| | - Yingqi Meng
- Jiading District Central Hospital Affiliated Shanghai University of Medicine and Health Sciences, Shanghai, 201800, PR China.
| |
Collapse
|
6
|
Juraeva M, Kang DJ. Design and Mixing Analysis of a Passive Micromixer Based on Curly Baffles. MICROMACHINES 2023; 14:1795. [PMID: 37763958 PMCID: PMC10535907 DOI: 10.3390/mi14091795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 09/15/2023] [Accepted: 09/18/2023] [Indexed: 09/29/2023]
Abstract
A novel passive micromixer based on curly baffles is proposed and optimized through the signal-to-noise analysis of various design parameters. The mixing performance of the proposed design was evaluated across a wide Reynolds number range, from 0.1 to 80. Through the analysis, the most influential parameter was identified, and its value was found to be constant regardless of the mixing mechanism. The optimized design, refined using the signal-to-noise analysis, demonstrated a significant enhancement of mixing performance, particularly in the low Reynolds number range (Re< 10). The design set obtained at the diffusion dominance range shows the highest degree of mixing (DOM) in the low Reynolds number range of Re< 10, while the design set optimized for the convection dominance range exhibited the least pressure drop across the entire Reynolds number spectrum (Re< 80). The present design approach proved to be a practical tool for identifying the most influential design parameter and achieving excellent mixing and pressure drop characteristics. The enhancement is mainly due to the curvature of the most influential design parameter.
Collapse
Affiliation(s)
| | - Dong-Jin Kang
- School of Mechanical Engineering, Yeungnam University, 280 Daehak-Ro, Gyeongsan 38541, Gyeongbuk, Republic of Korea;
| |
Collapse
|
7
|
Nai J, Zhang F, Dong P, Bai F, Fu T, Wang J, Ge A. Effect of Multiple Structural Parameters on the Performance of a Micromixer with Baffles, Obstacles, and Gaps. MICROMACHINES 2023; 14:1750. [PMID: 37763914 PMCID: PMC10534435 DOI: 10.3390/mi14091750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Revised: 09/04/2023] [Accepted: 09/05/2023] [Indexed: 09/29/2023]
Abstract
As an essential component of chip laboratories and microfluidic systems, micromixers are widely used in fields such as chemical and biological analysis. In this work, a square cavity micromixer with multiple structural parameters (baffles, obstacles, and gaps) has been proposed to further improve the mixing performance of micromixers. This study examines the comprehensive effects of various structural parameters on mixing performance. The impact of baffle length, obstacle length-to-width ratio, gap width, and obstacle shape on the mixing index and pressure drop were numerically studied at different Reynolds numbers (Re). The results show that the mixing index increases with baffle length and obstacle length-to-width ratio and decreases with gap width at Re = 0.1, 1, 10, 20, 40, and 60. The mixing index can reach more than 0.98 in the range of Re ≥ 20 when the baffle length is 150 μm, the obstacle length-to-width ratio is 600/100, and the gap width is 200 μm. The pressure drop of the microchannel is proportional to baffle length and obstacle length-to-width ratio. Combining baffles and obstacles can further improve the mixing performance of square cavity micromixers. A longer baffle length, larger obstacle length-to-width ratio, narrower gap width, and a more symmetrical structure are conducive to improving the mixing index. However, the impact of pressure drop must also be considered comprehensively. The research results provide references and new ideas for passive micromixer structural design.
Collapse
Affiliation(s)
- Jiacheng Nai
- Hubei Key Laboratory of Mechanical Transmission and Manufacturing Engineering, Wuhan University of Science and Technology, Wuhan 430081, China
| | - Feng Zhang
- Hubei Key Laboratory of Mechanical Transmission and Manufacturing Engineering, Wuhan University of Science and Technology, Wuhan 430081, China
| | - Peng Dong
- Key Laboratory of Metallurgical Equipment and Control Technology, Ministry of Education, Wuhan University of Science and Technology, Wuhan 430081, China
| | - Fan Bai
- School of Science, Wuhan University of Science and Technology, Wuhan 430081, China
| | - Ting Fu
- Precision Manufacturing Institute, Wuhan University of Science and Technology, Wuhan 430081, China
| | - Jiangbo Wang
- Precision Manufacturing Institute, Wuhan University of Science and Technology, Wuhan 430081, China
| | - Anle Ge
- Single-Cell Center, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101, China
| |
Collapse
|
8
|
Mou J, Wang C, Zhao H, Xiong C, Ren Y, Wang J, Jiang D, Zheng Z. Centrifugal Microfluidic Synthesis of Nickel Sesquioxide Nanoparticles. MICROMACHINES 2023; 14:1741. [PMID: 37763904 PMCID: PMC10538187 DOI: 10.3390/mi14091741] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 09/04/2023] [Accepted: 09/04/2023] [Indexed: 09/29/2023]
Abstract
Nickel sesquioxide (Ni2O3) nanoparticles were synthesized using centrifugal microfluidics in the present study. The obtained nanoparticles were characterized using SEM to investigate their morphology and microstructure, and XRD was employed to analyze their purity. The nanoparticle size data were measured and analyzed using ImageJ (v1.8.0) software. The flow process and mixing procedure were monitored through computational fluid dynamics simulation. Among the synthesized Ni2O3 nanoparticles, those obtained at the rotation speed of 1000 rpm for 10 min with angular acceleration of 4.2 rad/s2 showed the best performance in terms of high purity, complete shape and microstructure, small diameter, and narrow diameter distribution. The experimental results demonstrate that the rotation speed of the microfluidic chip and reaction time contribute to a decrease in particle diameter and a narrower diameter distribution range. In contrast, an increase in acceleration of the rotation speed leads to an expanded nanoparticle size range and, thus, a wider distribution. These findings contribute to a comprehensive understanding of the effects exerted by various factors in centrifugal microfluidics and will provide new insights into nanoparticle synthesis using centrifugal microfluidic technology.
Collapse
Affiliation(s)
- Jiayou Mou
- Research Group for Fluids and Thermal Engineering, University of Nottingham Ningbo China, Ningbo 315100, China;
- Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham Ningbo China, Ningbo 315100, China; (H.Z.); (C.X.)
| | - Chenxi Wang
- Chemical and Environmental Engineering, University of Nottingham Ningbo China, Ningbo 315100, China;
- New Materials Institute, University of Nottingham Ningbo China, Ningbo 315100, China
| | - Hongyi Zhao
- Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham Ningbo China, Ningbo 315100, China; (H.Z.); (C.X.)
| | - Chuwei Xiong
- Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham Ningbo China, Ningbo 315100, China; (H.Z.); (C.X.)
| | - Yong Ren
- Research Group for Fluids and Thermal Engineering, University of Nottingham Ningbo China, Ningbo 315100, China;
- Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham Ningbo China, Ningbo 315100, China; (H.Z.); (C.X.)
- Key Laboratory of Carbonaceous Wastes Processing and Process Intensification Research of Zhejiang Province, University of Nottingham Ningbo China, Ningbo 315100, China
- Nottingham Ningbo China Beacons of Excellence Research and Innovation Institute, University of Nottingham Ningbo China, Ningbo 315154, China
| | - Jing Wang
- Nottingham Ningbo China Beacons of Excellence Research and Innovation Institute, University of Nottingham Ningbo China, Ningbo 315154, China
- Department of Electrical and Electronic Engineering, University of Nottingham Ningbo China, Ningbo 315100, China
- Key Laboratory of More Electric Aircraft Technology of Zhejiang Province, University of Nottingham Ningbo China, Ningbo 315100, China
| | - Dan Jiang
- Ningbo Chemgoo Pharma Tech Co., Ltd., Ningbo 315800, China;
| | - Zansheng Zheng
- Ningbo Chemgoo Pharma Tech Co., Ltd., Ningbo 315800, China;
| |
Collapse
|
9
|
Juraeva M, Kang DJ. Mixing Performance of a Passive Micromixer Based on Multiple Baffles and Submergence Scheme. MICROMACHINES 2023; 14:mi14051078. [PMID: 37241701 DOI: 10.3390/mi14051078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 05/18/2023] [Accepted: 05/18/2023] [Indexed: 05/28/2023]
Abstract
A novel passive micromixer based on multiple baffles and a submergence scheme was designed, and its mixing performance was simulated over a wide range of Reynolds numbers ranging from 0.1 to 80. The degree of mixing (DOM) at the outlet and the pressure drop between the inlets and outlet were used to assess the mixing performance of the present micromixer. The mixing performance of the present micromixer showed a significant enhancement over a wide range of Reynolds numbers (0.1 ≤ Re ≤ 80). The DOM was further enhanced by using a specific submergence scheme. At low Reynolds numbers (Re < 5), submergence scheme Sub24 produced the highest DOM, approximately 0.57, which was 1.38 times higher than the case with no submergence. This enhancement was due to the fluid flowing from or toward the submerged space, creating strong upward or downward flow at the cross-section. At high Reynolds numbers (Re > 10), the DOM of Sub1234 became the highest, reaching approximately 0.93 for Re = 20, which was 2.75 times higher than the case with no submergence. This enhancement was caused by a large vortex formed across the whole cross-section, causing vigorous mixing between the two fluids. The large vortex dragged the interface between the two fluids along the vortex perimeter, elongating the interface. The amount of submergence was optimized in terms of DOM, and it was independent of the number of mixing units. The optimum submergence values were 90 μm for Sub24 and Re = 1, 100 μm for Sub234 and Re = 5, and 70 μm for Sub1234 and Re = 20.
Collapse
Affiliation(s)
- Makhsuda Juraeva
- School of Mechanical Engineering, Yeungnam University, Gyoungsan 38541, Republic of Korea
| | - Dong-Jin Kang
- School of Mechanical Engineering, Yeungnam University, Gyoungsan 38541, Republic of Korea
| |
Collapse
|
10
|
Gupta D, Nyande BW, Thomas KM, Li F, Mak AT, Lakerveld R. Induced-Charge Electroosmosis for Rapid Mixing of Reactive Precipitation Systems to Obtain Small and Uniform Particles. Chem Eng Res Des 2023. [DOI: 10.1016/j.cherd.2022.12.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
11
|
Ultrasonic cavitation-enabled microfluidic approach toward the continuous synthesis of cesium lead halide perovskite nanocrystals. Chin J Chem Eng 2022. [DOI: 10.1016/j.cjche.2022.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
12
|
Sun H, Li Z, Wu Y, Fan X, Zhu M, Chen T, Sun L. Analysis of Sequential Micromixing Driven by Sinusoidally Shaped Induced-Charge Electroosmotic Flow. MICROMACHINES 2022; 13:1985. [PMID: 36422414 PMCID: PMC9695967 DOI: 10.3390/mi13111985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/08/2022] [Accepted: 11/09/2022] [Indexed: 06/16/2023]
Abstract
Multi-fluid micromixing, which has rarely been explored, typically represents a highly sought-after technique in on-chip biochemical and biomedical assays. Herein, we propose a novel micromixing approach utilizing induced-charge electroosmosis (ICEO) to implement multicomplex mixing between parallel streams. The variations of ICEO microvortices above a sinusoidally shaped floating electrode (SSFE) are first investigated to better understand the microvortex development and the resultant mixing process within a confined channel. On this basis, a mathematical model of the vortex index is newly developed to predict the mixing degree along the microchannel. The negative exponential distribution obtained between the vortex index and mixing index demonstrates an efficient model to describe the mixing performance without solving the coupled diffusion and momentum equations. Specifically, sufficient mixing with a mixing index higher than 0.9 can be achieved when the vortex index exceeds 51, and the mixing efficiency reaches a plateau at an AC frequency close to 100 Hz. Further, a rectangle floating electrode (RFE) is deposited before SSFE to enhance the controlled sequence for three-fluid mixing. One side fluid can fully mix with the middle fluid with a mixing index of 0.623 above RFE in the first mixing stage and achieve entire-channel mixing with a mixing index of 0.983 above SSFE in the second mixing stage, thereby enabling on-demand sequential mixing. As a proof of concept, this work can provide a robust alternative technique for multi-objective issues and structural design related to mixers.
Collapse
Affiliation(s)
- Haizhen Sun
- School of Mechanical and Electric Engineering, Soochow University, Suzhou 215299, China
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215123, China
| | - Ziyi Li
- School of Mechanical and Electric Engineering, Soochow University, Suzhou 215299, China
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215123, China
| | - Yongji Wu
- School of Mechanical and Electric Engineering, Soochow University, Suzhou 215299, China
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215123, China
| | - Xinjian Fan
- School of Mechanical and Electric Engineering, Soochow University, Suzhou 215299, China
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215123, China
| | - Minglu Zhu
- School of Mechanical and Electric Engineering, Soochow University, Suzhou 215299, China
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215123, China
| | - Tao Chen
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215123, China
- School of Future Science and Engineering, Soochow University, Suzhou 215299, China
| | - Lining Sun
- School of Mechanical and Electric Engineering, Soochow University, Suzhou 215299, China
- Jiangsu Provincial Key Laboratory of Advanced Robotics, School of Mechanical and Electric Engineering, Soochow University, Suzhou 215123, China
| |
Collapse
|
13
|
Juraeva M, Kang DJ. Mixing Performance of the Modified Tesla Micromixer with Tip Clearance. MICROMACHINES 2022; 13:1375. [PMID: 36143998 PMCID: PMC9502868 DOI: 10.3390/mi13091375] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/10/2022] [Accepted: 08/18/2022] [Indexed: 06/01/2023]
Abstract
A passive micromixer based on the modified Tesla mixing unit was designed by embedding tip clearance above the wedge-shape divider, and its mixing performance was simulated over a wider range of the Reynolds numbers from 0.1 to 80. The mixing performance was evaluated in terms of the degree of mixing (DOM) at the outlet and the required pressure load between inlet and outlet. The height of tip clearance was varied from 40 μm to 80 μm, corresponding to 25% to 33% of the micromixer depth. The numerical results show that the mixing enhancement by the tip clearance is noticeable over a wide range of the Reynolds numbers Re < 50. The height of tip clearance is optimized in terms of the DOM, and the optimum value is roughly h = 60 μm. It corresponds to 33% of the present micromixer depth. The mixing enhancement in the molecular diffusion regime of mixing, Re ≤ 1, is obtained by drag and connection of the interface in the two sub-streams of each Tesla mixing unit. It appears as a wider interface in the tip clearance zone. In the intermediate range of the Reynolds number, 1 < Re ≤ 50, the mixing enhancement is attributed to the interaction of the flow through the tip clearance and the secondary flow in the vortex zone of each Tesla mixing unit. When the Reynolds number is larger than about 50, vortices are formed at various locations and drive the mixing in the modified Tesla micromixer. For the Reynolds number of Re = 80, a pair of vortices is formed around the inlet and outlet of each Tesla mixing unit, and it plays a role as a governing mechanism in the convection-dominant regime of mixing. This vortex pattern is little affected as long as the tip clearance remains smaller than about h = 70 μm. The DOM at the outlet is little enhanced by the presence of tip clearance for the Reynolds numbers Re ≥ 50. The tip clearance contributes to reducing the required pressure load for the same value of the DOM.
Collapse
Affiliation(s)
| | - Dong-Jin Kang
- School of Mechanical Engineering, Yeungnam University, Gyoungsan 38541, Korea
| |
Collapse
|
14
|
Qi W, Zheng L, Hou Y, Duan H, Wang L, Wang S, Liu Y, Li Y, Liao M, Lin J. A finger-actuated microfluidic biosensor for colorimetric detection of foodborne pathogens. Food Chem 2022; 381:131801. [DOI: 10.1016/j.foodchem.2021.131801] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 11/19/2021] [Accepted: 12/03/2021] [Indexed: 01/13/2023]
|
15
|
Juraeva M, Kang DJ. Mixing Enhancement of a Passive Micromixer with Submerged Structures. MICROMACHINES 2022; 13:mi13071050. [PMID: 35888870 PMCID: PMC9317626 DOI: 10.3390/mi13071050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 06/24/2022] [Accepted: 06/28/2022] [Indexed: 11/26/2022]
Abstract
A passive micromixer combined with two different mixing units was designed by submerging planar structures, and its mixing performance was simulated over a wider range of the Reynolds numbers from 0.1 to 80. The two submerged structures are a Norman window and rectangular baffles. The mixing performance was evaluated in terms of the degree of mixing (DOM) at the outlet and the required pressure load between inlet and outlet. The amount of submergence was varied from 30 μm to 70 μm, corresponding to 25% to 58% of the micromixer depth. The enhancement of mixing performance is noticeable over a wide range of the Reynolds numbers. When the Reynolds number is 10, the DOM is improved by 182% from that of no submergence case, and the required pressure load is reduced by 44%. The amount of submergence is shown to be optimized in terms of the DOM, and the optimum value is about 40 μm. This corresponds to a third of the micromixer depth. The effects of the submerged structure are most significant in the mixing regime of convection dominance from Re = 5 to 80. In a circular passage along the Norman window, one of the two Dean vortices burst into the submerged space, promoting mixing in the cross-flow direction. The submerged baffles in the semi-circular mixing units generate a vortex behind the baffles that contributes to the mixing enhancement as well as reducing the required pressure load.
Collapse
|
16
|
Enhancement of Binding Kinetics on Affinity Substrates Using Asymmetric Electroosmotic Flow on a Sinusoidal Bipolar Electrode. MICROMACHINES 2022; 13:mi13020207. [PMID: 35208334 PMCID: PMC8878551 DOI: 10.3390/mi13020207] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/18/2022] [Accepted: 01/23/2022] [Indexed: 02/04/2023]
Abstract
In the context of the COVID-19 epidemic, enhancing the transport of analyte to a sensor surface is crucial for rapid detection of biomolecules since common conditions, including low diffusion coefficients, cause inordinately long detection times. Integrated microfluidic immunoassay chips are receiving increasing attention for their low sample volume and fast response time. We herein take advantage of asymmetric ICEO flow at a bipolar sinusoidal electrode to improve the rate of antibody binding to the reaction surface based on finite element modeling. Three different microfluidic cavities are proposed by changing the positions of the surface reaction area. We further investigate the relationship between binding enhancement and reaction surface positions, Damkohler number, and the voltage and frequency of the AC signal applied to the driving electrodes. Furthermore, the influence of the AC signal applied to the sinusoidal bipolar electrode on antigen–antibody-binding performance is studied in detail. Above all, the simulation results demonstrate that the microfluidic immune-sensor with a sinusoidal bipolar electrode could not only significantly improve the heterogeneous immunoassays but also enable efficient enhancement of assays in a selected reaction region within the micro-cavity, providing a promising approach to a variety of immunoassay applications, such as medical diagnostics and environmental and food monitoring.
Collapse
|
17
|
Wu Y, Hu B, Ma X, Zhang H, Li W, Wang Y, Wang S. Generation of droplets with adjustable chemical concentrations based on fixed potential induced-charge electro-osmosis. LAB ON A CHIP 2022; 22:403-412. [PMID: 34950939 DOI: 10.1039/d1lc00983d] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The effective control of the sample concentration within droplets is essential in a broad range of assays in chemistry and biochemistry. Here we provide an electrical method for producing batches of aqueous droplets with various chemical concentrations by exploiting fixed-potential induced-charge electroosmosis (ICEO) flow around a bipolar electrode. By applying an AC electric signal to the bipolar electrode and changing the zeta potential on it, the bipolar electrode acts as a gate electrode for generating asymmetric ICEO flow. The ICEO flow induced transverse vortexes interact with two parallel laminar streams with different chemical compositions. Controlled mixing of the aqueous solutions can be achieved by adjusting the shape and size of the asymmetric vortexes via altering the electric signal applied to the gate electrode. The mixed streams are split at a bifurcation, and one of the streams with a desired controlled concentration is pumped into a flow-focusing geometry to generate droplets with adjustable chemical concentrations. The in-droplet concentration increases in the range of 0.412-1.404 mM, as the applied voltage increases in the range of 0-70 mV at 15 kHz. This approach offers a promising method for on-chip control of chemical concentrations within droplets without labor-intensive dilutions while minimizing the sample consumption, showing great potential for next generation droplet-based applications.
Collapse
Affiliation(s)
- Yupan Wu
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China.
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, 518000, PR China
- Yangtze River Delta Research Institute of NPU, Taicang, 215400, PR China
| | - Bowen Hu
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China.
| | - Xun Ma
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China.
| | - Haohao Zhang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China.
| | - Wei Li
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China.
| | - Yucheng Wang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China.
| | - Shaoxi Wang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, 710072, PR China.
| |
Collapse
|
18
|
Juraeva M, Kang DJ. Mixing Performance of a Passive Micro-Mixer with Mixing Units Stacked in Cross Flow Direction. MICROMACHINES 2021; 12:mi12121530. [PMID: 34945380 PMCID: PMC8705926 DOI: 10.3390/mi12121530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/30/2021] [Accepted: 12/06/2021] [Indexed: 12/02/2022]
Abstract
A new passive micro-mixer with mixing units stacked in the cross flow direction was proposed, and its performance was evaluated numerically. The present micro-mixer consisted of eight mixing units. Each mixing unit had four baffles, and they were arranged alternatively in the cross flow and transverse direction. The mixing units were stacked in four different ways: one step, two step, four step, and eight step stacking. A numerical study was carried out for the Reynolds numbers from 0.5 to 50. The corresponding volume flow rate ranged from 6.33 μL/min to 633 μL/min. The mixing performance was analyzed in terms of the degree of mixing (DOM) and relative mixing energy cost (MEC). The numerical results showed a noticeable enhancement of the mixing performance compared with other micromixers. The mixing enhancement was achieved by two flow characteristics: baffle wall impingement by a stream of high concentration and swirl motion within the mixing unit. The baffle wall impingement by a stream of high concentration was observed throughout all Reynolds numbers. The swirl motion inside the mixing unit was observed in the cross flow direction, and became significant as the Reynolds number increased to larger than about five. The eight step stacking showed the best performance for Reynolds numbers larger than about two, while the two step stacking was better for Reynolds numbers less than about two.
Collapse
|
19
|
Jiang T, Wu Y. Controlled generation of droplets using an electric field in a flow-focusing paper-based device. Electrophoresis 2021; 43:601-608. [PMID: 34747509 DOI: 10.1002/elps.202100245] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 11/01/2021] [Accepted: 11/03/2021] [Indexed: 11/06/2022]
Abstract
Droplet-based microfluidics is a modular platform in high-throughput single-cell and small sample analyses. However, this droplet microfluidic system was widely fabricated using soft lithography or glass capillaries, which is expensive and technically demanding for various applications, limiting use in resource-poor settings. Besides, the variation in droplet size is also restricted due to the limitations on the operating forces that the paper-based platform is able to withstand. Herein, we develop a fully integrated paper-based droplet microfluidic platform for conducting droplet generation and cell encapsulation in independent aqueous droplets dispersed in a carrier oil by incorporating electric fields. Through imposing an electric field, the droplet size would decrease with increasing the electric field and smaller droplets can be produced at high applied voltage. The droplet diameter can be adjusted by the ratio of inner and outer flow velocities as well as the applied electric field. We also demonstrated the proof of concept encapsulation application of our paper device by encapsulating yeast cells under an electric field. Using a simple wax printing method, carbon electrodes can be integrated on the paper. The integrated paper-based microfluidic platform can be fabricated easily and conducted outside of centralized laboratories. This microfluidic system shows great potential in drug and cell investigations by encapsulating cells in resource-limited environments.
Collapse
Affiliation(s)
- Tianyi Jiang
- School of Microelectronics, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Yupan Wu
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, P. R. China.,School of Microelectronics, Northwestern Polytechnical University, Xi'an, P. R. China.,Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Yangtze River Delta Research Institute of NPU, Taicang, P. R. China
| |
Collapse
|
20
|
López RR, Sánchez LM, Alazzam A, Burnier JV, Stiharu I, Nerguizian V. Numerical and Experimental Validation of Mixing Efficiency in Periodic Disturbance Mixers. MICROMACHINES 2021; 12:mi12091102. [PMID: 34577745 PMCID: PMC8469598 DOI: 10.3390/mi12091102] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 09/08/2021] [Accepted: 09/09/2021] [Indexed: 02/05/2023]
Abstract
The shape and dimensions of a micromixer are key elements in the mixing process. Accurately quantifying the mixing efficiency enables the evaluation of the performance of a micromixer and the selection of the most suitable one for specific applications. In this paper, two methods are investigated to evaluate the mixing efficiency: a numerical model and an experimental model with a software image processing technique. Using two methods to calculate the mixing efficiency, in addition to corroborating the results and increasing their reliability, creates various possible approaches that can be selected depending on the circumstances, resources, amount of data to be processed and processing time. Image processing is an easy-to-implement tool, is applicable to different programming languages, is flexible, and provides a quick response that allows the calculation of the mixing efficiency using a process of filtering of images and quantifying the intensity of the color, which is associated with the percentage of mixing. The results showed high similarity between the two methods, with a difference ranging between 0 and 6% in all the evaluated points.
Collapse
Affiliation(s)
- Rubén R. López
- Department of Electrical Engineering, École de Technologie Supérieure, 1100 Notre Dame West, Montreal, QC H3C 1K3, Canada; (A.A.); (V.N.)
- Cancer Research Program, RI-MUHC, McGill University, 1001 Decarie Boulevard, Montreal, QC H4A 3J1, Canada;
- Correspondence: (R.R.L.); (L.-M.S.); Tel.: +1-915-232-0336 (R.R.L.)
| | - Luz-María Sánchez
- Department of Engineering, Universidad Autónoma de Querétaro, Cerro de las Campanas, Santiago de Querétaro 76010, Querétaro, Mexico
- Correspondence: (R.R.L.); (L.-M.S.); Tel.: +1-915-232-0336 (R.R.L.)
| | - Anas Alazzam
- Department of Electrical Engineering, École de Technologie Supérieure, 1100 Notre Dame West, Montreal, QC H3C 1K3, Canada; (A.A.); (V.N.)
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi 127788, United Arab Emirates
| | - Julia V. Burnier
- Cancer Research Program, RI-MUHC, McGill University, 1001 Decarie Boulevard, Montreal, QC H4A 3J1, Canada;
| | - Ion Stiharu
- Department of Mechanical and Industrial Engineering, Concordia University, 1515 Saint Catherine West, Montreal, QC H3G 1M8, Canada;
| | - Vahé Nerguizian
- Department of Electrical Engineering, École de Technologie Supérieure, 1100 Notre Dame West, Montreal, QC H3C 1K3, Canada; (A.A.); (V.N.)
| |
Collapse
|
21
|
Juraeva M, Kang DJ. Optimal Combination of Mixing Units Using the Design of Experiments Method. MICROMACHINES 2021; 12:985. [PMID: 34442607 PMCID: PMC8398973 DOI: 10.3390/mi12080985] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 08/03/2021] [Accepted: 08/11/2021] [Indexed: 12/03/2022]
Abstract
A passive micromixer was designed by combining two mixing units: the cross-channel split and recombined (CC-SAR) and a mixing cell with baffles (MC-B). The passive micromixer was comprised of eight mixing slots that corresponded to four combination units; two mixing slots were grouped as one combination unit. The combination of the two mixing units was based on four combination schemes: (A) first mixing unit, (B) first combination unit, (C) first combination module, and (D) second combination module. The statistical significance of the four combination schemes was analyzed using analysis of variance (ANOVA) in terms of the degree of mixing (DOM) and mixing energy cost (MEC). The DOM and MEC were simulated numerically for three Reynolds numbers (Re = 0.5, 2, and 50), representing three mixing regimes. The combination scheme (B), using different mixing units in the first two mixing slots, was significant for Re = 2 and 50. The four combination schemes had little effect on the mixing performance of a passive micromixer operating in the mixing regime of molecular dominance. The combination scheme (B) was generalized to arbitrary mixing slots, and its significance was analyzed for Re = 2 and 50. The general combination scheme meant two different mixing units in two consecutive mixing slots. The numerical simulation results showed that the general combination scheme was statistically significant in the first three combination units for Re = 2, and significant in the first two combination units for Re = 50. The combined micromixer based on the general combination scheme throughout the entire micromixer showed the best mixing performance over a wide range of Reynolds numbers, compared to other micromixers that did not adopt completely the general combination scheme. The most significant enhancement due to the general combination scheme was observed in the transition mixing scheme and was negligible in the molecular dominance scheme. The combination order was less significant after three combination units.
Collapse
Affiliation(s)
| | - Dong-Jin Kang
- School of Mechanical Engineering, Yeungnam University, Gyoungsan 712-749, Korea;
| |
Collapse
|
22
|
Shi L, Ding H, Zhong X, Yin B, Liu Z, Zhou T. Mixing Mechanism of Microfluidic Mixer with Staggered Virtual Electrode Based on Light-Actuated AC Electroosmosis. MICROMACHINES 2021; 12:mi12070744. [PMID: 34202893 PMCID: PMC8306084 DOI: 10.3390/mi12070744] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 06/13/2021] [Accepted: 06/23/2021] [Indexed: 02/02/2023]
Abstract
In this paper, we present a novel microfluidic mixer with staggered virtual electrode based on light-actuated AC electroosmosis (LACE). We solve the coupled system of the flow field described by Navier–Stokes equations, the described electric field by a Laplace equation, and the concentration field described by a convection–diffusion equation via a finite-element method (FEM). Moreover, we study the distribution of the flow, electric, and concentration fields in the microchannel, and reveal the generating mechanism of the rotating vortex on the cross-section of the microchannel and the mixing mechanism of the fluid sample. We also explore the influence of several key geometric parameters such as the length, width, and spacing of the virtual electrode, and the height of the microchannel on mixing performance; the relatively optimal mixer structure is thus obtained. The current micromixer provides a favorable fluid-mixing method based on an optical virtual electrode, and could promote the comprehensive integration of functions in modern microfluidic-analysis systems.
Collapse
Affiliation(s)
- Liuyong Shi
- Mechanical and Electrical Engineering College, Hainan University, Haikou 570228, China; (L.S.); (H.D.); (X.Z.)
| | - Hanghang Ding
- Mechanical and Electrical Engineering College, Hainan University, Haikou 570228, China; (L.S.); (H.D.); (X.Z.)
| | - Xiangtao Zhong
- Mechanical and Electrical Engineering College, Hainan University, Haikou 570228, China; (L.S.); (H.D.); (X.Z.)
| | - Binfeng Yin
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China;
| | - Zhenyu Liu
- Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China;
| | - Teng Zhou
- Mechanical and Electrical Engineering College, Hainan University, Haikou 570228, China; (L.S.); (H.D.); (X.Z.)
- Correspondence: ; Tel.: +86-186-8963-7366
| |
Collapse
|
23
|
Ghorbani Kharaji Z, Bayareh M, Kalantar V. A review on acoustic field-driven micromixers. INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING 2021. [DOI: 10.1515/ijcre-2020-0188] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
A review on acoustic field-driven micromixers is given. This is supplemented by the governing equations, governing non-dimensional parameters, numerical simulation approaches, and fabrication techniques. Acoustically induced vibration is a kind of external energy input employed in active micromixers to improve the mixing performance. An air bubble energized by an acoustic field acts as an external energy source and induces friction forces at the interface between an air bubble and liquid, leading to the formation of circulatory flows. The current review (with 200 references) evaluates different characteristics of microfluidic devices working based on acoustic field shaking.
Collapse
Affiliation(s)
| | - Morteza Bayareh
- Department of Mechanical Engineering , Shahrekord University , Shahrekord , Iran
| | - Vali Kalantar
- Department of Mechanical Engineering , Yazd University , Yazd , Iran
| |
Collapse
|
24
|
Wu Y, Chattaraj R, Ren Y, Jiang H, Lee D. Label-Free Multitarget Separation of Particles and Cells under Flow Using Acoustic, Electrophoretic, and Hydrodynamic Forces. Anal Chem 2021; 93:7635-7646. [PMID: 34014074 DOI: 10.1021/acs.analchem.1c00312] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Multiplex separation of mixed biological samples is essential in a considerable portion of biomedical research and clinical applications. An automated and operator-independent process for the separation of samples is highly sought after. There is a significant unmet need for methods that can perform fractionation of small volumes of multicomponent mixtures. Herein, we design an integrated chip that combines acoustic and electric fields to enable efficient and label-free separation of multiple different cells and particles under flow. To facilitate the connection of multiple sorting mechanisms in tandem, we investigate the electroosmosis (EO)-induced deterministic lateral displacement (DLD) separation in a combined pressure- and DC field-driven flow and exploit the combination of the bipolar electrode (BPE) focusing and surface acoustic wave (SAW) sorting modules. We successfully integrate four sequential microfluidic modules for multitarget separation within a single platform: (i) sorting particles and cells relying on the size and surface charge by adjusting the flow rate and electric field using a DLD array; (ii) alignment of cells or particles within a microfluidic channel by a bipolar electrode; (iii) separation of particles based on compressibility and density by the acoustic force; and (iv) separation of viable and nonviable cells using dielectric properties via the dielectrophoresis (DEP) force. As a proof of principle, we demonstrate the sorting of multiple cell and particle types (polystyrene (PS) particles, oil droplets, and viable and nonviable yeast cells) with high efficiency. This integrated microfluidic platform combines multiple functional components and, with its ability to noninvasively sort multiple targeted cells in a label-free manner relying on different properties, is compatible with high-definition imaging, showing great potential in diverse diagnostic and analysis applications.
Collapse
Affiliation(s)
- Yupan Wu
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.,School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China.,School of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, P. R. China.,Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen 518000, P. R. China.,Yangtze River Delta Research Institute of NPU, Taicang 215400, P. R. China
| | - Rajarshi Chattaraj
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Yukun Ren
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China
| | - Hongyuan Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, P. R. China
| | - Daeyeon Lee
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
25
|
Modarres P, Tabrizian M. Phase-controlled field-effect micromixing using AC electroosmosis. MICROSYSTEMS & NANOENGINEERING 2020; 6:60. [PMID: 34567671 PMCID: PMC8433414 DOI: 10.1038/s41378-020-0166-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Accepted: 02/05/2020] [Indexed: 05/08/2023]
Abstract
The exploration and application of electrokinetic techniques in micro total analysis systems have become ubiquitous in recent years, and scientists are expanding the use of such techniques in areas where comparable active or passive methods are not as successful. In this work, for the first time, we utilize the concept of AC electroosmosis to design a phase-controlled field-effect micromixer that benefits from a three-finger sinusoidally shaped electrodes. Analogous to field-effect transistor devices, the principle of operation for the proposed micromixer is governed by the source-gate and source-drain voltage potentials that are modulated by introducing a phase lag between the driving electrodes. At an optimized flow rate and biasing scheme, we demonstrate that the source, gate, and drain voltage phase relations can be configured such that the micromixer switches from an unmixed state (phase shift of 0°) to a mixed state (phase shift of 180°). High mixing efficiencies beyond 90% was achieved at a volumetric flow rate of 4 µL/min corresponding to ~13.9 mm/s at optimized voltage excitation conditions. Finally, we employed the proposed micromixer for the synthesis of nanoscale lipid-based drug delivery vesicles through the process of electrohydrodynamic-mediated nanoprecipitation. The phase-controlled electrohydrodynamic mixing utilized for the nanoprecipitation technique proved that nanoparticles of improved monodispersity and concentration can be produced when mixing efficiency is enhanced by tuning the phase shifts between electrodes.
Collapse
Affiliation(s)
- Paresa Modarres
- Biomedical Engineering Department, McGill University, Montreal, QC Canada
| | - Maryam Tabrizian
- Biomedical Engineering Department, McGill University, Montreal, QC Canada
- Faculty of Dentistry, McGill University, 2001 McGill College Ave, Montreal, QC Canada
| |
Collapse
|
26
|
Inertial Micromixing in Curved Serpentine Micromixers with Different Curve Angles. FLUIDS 2019. [DOI: 10.3390/fluids4040204] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Micromixers are of considerable significance in many microfluidics system applications, from chemical reactions to biological analysis processes. Passive micromixers, which rely solely on their geometry, have the advantages of low cost and a less-complex fabrication process. Dean vortices seen in curved microchannels are one of the useful tools to enhance micromixing. In this study, the effects of curve angle on micromixing were experimentally investigated in three curved serpentine micromixers consisting of ten segments with curve angles of 180 ° , 230 ° and 280 ° , at Dean numbers between 12 and 87. To characterize and compare the performance of the micromixers, fluorescence intensity maps and mixing indices were utilized. Accordingly, the micromixer having segments with 280 ° curve angle had significantly higher mixing index values up to the Dean number 60 and outperformed the other two micromixers. This was due to the severe distortion of flow streamlines by Dean vortices and the occurrence of chaotic advection at lower Dean numbers. Beyond the Dean number of 70, no difference was observed in the performance of the micromixers and the mixing index at their outlets had the asymptotic value of 0.93 ± 0.02. Furthermore, the flow behavior of the micromixers was numerically simulated to provide further insight about the mixing phenomena.
Collapse
|
27
|
Tallapragada P, Sudarsanam S. Chaotic advection and mixing by a pair of microrotors in a circular domain. Phys Rev E 2019; 100:062207. [PMID: 31962448 DOI: 10.1103/physreve.100.062207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Indexed: 06/10/2023]
Abstract
In this work we study chaotic mixing induced by point microrotors in a bounded two-dimensional Stokes flow. The dynamics of the pair of rotors, modeled as rotlets, are non-Hamiltonian in the bounded domain and produce chaotic advection of fluid tracers in subsets of the domain. A complete parametric investigation of the fluid mixing as a function of the initial locations of the rotlets is performed based on pseudophase portraits. The mixing of fluid tracers as a function of relative positions of microrotors is studied using finite-time entropy and locational entropy. The finite-time locational entropy is used to identify regions of the fluid that produce good versus poor mixing, and this is visualized by the stretching and folding of blobs of tracer particles. Unlike the case of the classic blinking vortex dynamics, the velocity field of the flow modeled using rotlets inside a circular boundary is smooth in time and satisfies the no-slip boundary condition. This makes the considered model a more realistic case for studies of mixing in microfluidic devices using magnetic-actuated microspheres.
Collapse
Affiliation(s)
- Phanindra Tallapragada
- Department of Mechanical Engineering, Clemson University, Clemson, South Carolina 29634, USA
| | - Senbagaraman Sudarsanam
- Department of Mechanical Engineering, Mahindra École Centrale, Hyderabad, Telangana 500043, India
| |
Collapse
|
28
|
Sun H, Ren Y, Hou L, Tao Y, Liu W, Jiang T, Jiang H. Continuous Particle Trapping, Switching, and Sorting Utilizing a Combination of Dielectrophoresis and Alternating Current Electrothermal Flow. Anal Chem 2019; 91:5729-5738. [DOI: 10.1021/acs.analchem.8b05861] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
29
|
Wu Y, Ren Y, Han L, Yan Y, Jiang H. Three-dimensional paper based platform for automatically running multiple assays in a single step. Talanta 2019; 200:177-185. [PMID: 31036171 DOI: 10.1016/j.talanta.2019.03.033] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2018] [Revised: 01/19/2019] [Accepted: 03/05/2019] [Indexed: 01/19/2023]
Abstract
Paper based assays are paving the way to automated, simplified, robust and cost-effective point of care testing (POCT). We propose a method for fabricating three dimensional (3D) microfluidic paper based analytical devices (μPADs) via combining thin adhesive films and paper folding, which avoids the use of cellulose powders and the complex folding sequence and simultaneously permits assays in several layers. To demonstrate the effectiveness of this approach, a 3DμPADs was designed to conduct more assays on a small footprint, allowing dual colorimetric and electrochemical detections. More importantly, we further developed a 3D platform for implementing automated and multiplexed ELISA in parallel, since ELISA, a routine and standard laboratory method, has rarely been used in practical analyses outside of the laboratory. In this configuration, complex and multistep diagnostic assays can be carried out with the addition of the sample and buffer in a simple fashion. Using Troponin I as model, the device showed a broad dynamic range of detection with a detection limit of 0.35 ng/mL. Thus, the developed platforms allow for various assays to be cost-effectively carried out on a single 3D device, showing great potential in an academic setting and point of care testing under resource-poor conditions.
Collapse
Affiliation(s)
- Yupan Wu
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China
| | - Yukun Ren
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China; State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China.
| | - Lianhuan Han
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China
| | - Yongda Yan
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China; State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China
| | - Hongyuan Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China; State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China.
| |
Collapse
|
30
|
Gong H, Woolley AT, Nordin GP. 3D printed selectable dilution mixer pumps. BIOMICROFLUIDICS 2019; 13:014106. [PMID: 30766649 PMCID: PMC6353643 DOI: 10.1063/1.5070068] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Accepted: 01/16/2019] [Indexed: 05/03/2023]
Abstract
In this paper, we demonstrate the ability to 3D print tightly integrated structures with active valves, pumps, and mixers, and we use our compact chip-to-chip interconnects [Gong et al., Lab Chip 18, 639-647 (2018)] to move bulky world-to-chip connections to separate interface chips for both post-print flushing and post-cure device operation. As example devices, we first examine 3D printed pumps, followed by two types of selectable ratio mixer pumps, a linear dilution mixer pump (LDMP) and a parallelized dilution mixer pump (PDMP), which occupy volumes of only 1.5 mm 3 and 2.6 mm 3 , respectively. The LDMP generates a selectable dilution ratio from a linear set of possibilities, while the PDMP generates a denser set of possible dilutions with a maximum dilution ratio of 1/16. The PDMP also incorporates a new 4-to-1 valve to simultaneously control 4 inlet channels. To characterize LDMP and PDMP operation and performance, we present a new, low-cost video method to directly measure the relative concentration of an absorptive dye on a pixel-by-pixel basis for each video frame. Using this method, we find that 6 periods of the active mixer that forms the core of the LDMP and PDMP are sufficient to fully mix the fluid, and that the generated concentrations track the designed dilution ratios as expected. The LDMP mixes 20 nl per 4.6 s mixer pump period, while the PDMP uses parallelized input pumps to process the same fluid volume with greater choice of dilution ratios in a 3.6 s period.
Collapse
Affiliation(s)
- Hua Gong
- Electrical and Computer Engineering Department, Brigham Young University, Provo, Utah 84602, USA
| | - Adam T Woolley
- Chemistry and Biochemistry Department, Brigham Young University, Provo, Utah 84602, USA
| | - Gregory P Nordin
- Electrical and Computer Engineering Department, Brigham Young University, Provo, Utah 84602, USA
| |
Collapse
|
31
|
Sun H, Ren Y, Liu W, Feng X, Hou L, Tao Y, Jiang H. Flexible Continuous Particle Beam Switching via External-Field-Reconfigurable Asymmetric Induced-Charge Electroosmosis. Anal Chem 2018; 90:11376-11384. [DOI: 10.1021/acs.analchem.8b02332] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
| | | | - Weiyu Liu
- School of Electronics and Control Engineering, Chang’an University, Middle-Section of Nan’er Huan Road, Xi’an, Shaanxi 710064, People’s Republic of China
| | | | | | | | | |
Collapse
|
32
|
Wu Y, Ren Y, Tao Y, Hou L, Jiang H. High-Throughput Separation, Trapping, and Manipulation of Single Cells and Particles by Combined Dielectrophoresis at a Bipolar Electrode Array. Anal Chem 2018; 90:11461-11469. [DOI: 10.1021/acs.analchem.8b02628] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
33
|
Hu Q, Guo J, Cao Z, Jiang H. Asymmetrical Induced Charge Electroosmotic Flow on a Herringbone Floating Electrode and Its Application in a Micromixer. MICROMACHINES 2018; 9:E391. [PMID: 30424324 PMCID: PMC6187465 DOI: 10.3390/mi9080391] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 07/29/2018] [Accepted: 08/01/2018] [Indexed: 12/22/2022]
Abstract
Enhancing mixing is of significant importance in microfluidic devices characterized by laminar flows and low Reynolds numbers. An asymmetrical induced charge electroosmotic (ICEO) vortex pair generated on the herringbone floating electrode can disturb the interface of two-phase fluids and deliver the fluid transversely, which could be exploited to accomplish fluid mixing between two neighbouring fluids in a microscale system. Herein we present a micromixer based on an asymmetrical ICEO flow induced above the herringbone floating electrode array surface. We investigate the average transverse ICEO slip velocity on the Ridge/Vee/herringbone floating electrode and find that the microvortex generated on the herringbone electrode surface has good potential for mixing the miscible liquids in microfluidic systems. In addition, we explore the effect of applied frequencies and bulk conductivity on the slip velocity above the herringbone floating electrode surface. The high dependence of mixing performance on the floating electrode pair numbers is analysed simultaneously. Finally, we investigate systematically voltage intensity, applied frequencies, inlet fluid velocity and liquid conductivity on the mixing performance of the proposed device. The microfluidic micromixer put forward herein offers great opportunity for fluid mixing in the field of micro total analysis systems.
Collapse
Affiliation(s)
- Qingming Hu
- School of Mechatronics Engineering, Qiqihar University, Wenhua Street 42, Qiqihar 161006, China.
| | - Jianhua Guo
- School of Mechatronics Engineering, Qiqihar University, Wenhua Street 42, Qiqihar 161006, China.
| | - Zhongliang Cao
- School of Mechatronics Engineering, Qiqihar University, Wenhua Street 42, Qiqihar 161006, China.
| | - Hongyuan Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, China.
| |
Collapse
|
34
|
Cai G, Xue L, Zhang H, Lin J. A Review on Micromixers. MICROMACHINES 2017; 8:E274. [PMID: 30400464 PMCID: PMC6189760 DOI: 10.3390/mi8090274] [Citation(s) in RCA: 176] [Impact Index Per Article: 25.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Revised: 08/30/2017] [Accepted: 09/01/2017] [Indexed: 01/23/2023]
Abstract
Microfluidic devices have attracted increasing attention in the fields of biomedical diagnostics, food safety control, environmental protection, and animal epidemic prevention. Micromixing has a considerable impact on the efficiency and sensitivity of microfluidic devices. This work reviews recent advances on the passive and active micromixers for the development of various microfluidic chips. Recently reported active micromixers driven by pressure fields, electrical fields, sound fields, magnetic fields, and thermal fields, etc. and passive micromixers, which owned two-dimensional obstacles, unbalanced collisions, spiral and convergence-divergence structures or three-dimensional lamination and spiral structures, were summarized and discussed. The future trends for micromixers to combine with 3D printing and paper channel were brought forth as well.
Collapse
Affiliation(s)
- Gaozhe Cai
- Key Laboratory of Agricultural Information Acquisition Technology (Beijing) of Ministry of Agriculture, China Agricultural University, 17 East Qinghua Road, Beijing 100083, China.
| | - Li Xue
- Key Laboratory of Agricultural Information Acquisition Technology (Beijing) of Ministry of Agriculture, China Agricultural University, 17 East Qinghua Road, Beijing 100083, China.
| | - Huilin Zhang
- Key Laboratory of Agricultural Information Acquisition Technology (Beijing) of Ministry of Agriculture, China Agricultural University, 17 East Qinghua Road, Beijing 100083, China.
| | - Jianhan Lin
- Modern Precision Agriculture System Integration Research Key Laboratory of Ministry of Education, China Agricultural University, 17 East Qinghua Road, Beijing 100083, China.
| |
Collapse
|
35
|
Hu Q, Ren Y, Liu W, Tao Y, Jiang H. Simulation Analysis of Improving Microfluidic Heterogeneous Immunoassay Using Induced Charge Electroosmosis on a Floating Gate. MICROMACHINES 2017; 8:E212. [PMID: 30400403 PMCID: PMC6190211 DOI: 10.3390/mi8070212] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Revised: 07/02/2017] [Accepted: 07/03/2017] [Indexed: 11/16/2022]
Abstract
On-chip immuno-sensors are a hot topic in the microfluidic community, which is usually limited by slow diffusion-dominated transport of analytes in confined microchannels. Specifically, the antigen-antibody binding reaction at a functionalized area cannot be provided with enough antigen source near the reaction surface, since a small diffusion flux cannot match with the quick rate of surface reaction, which influences the response time and sensitivity of on-chip heterogeneous immunoassay. In this work, we propose a method to enhance the transportation of biomolecules to the surface of an antibody-immobilized electrode with induce charge electroosmotic (ICEO) convection in a low concentration suspension, so as to improve the binding efficiency of microfluidic heterogeneous immunoassays. The circular stirring fluid motion of ICEO on the surface of a floating gate electrode at the channel bottom accelerates the transport of freely suspended antigen towards the wall-immobilized antibodies. We investigate the dependence of binding efficiency on voltage magnitude and field frequency of the applied alternate current (AC) electrical field. The binding rate yields a factor of 5.4 higher binding for an applied voltage of 4 V at 10 Hz when the Damkohler number is 1000. The proposed microfluidic immuno-sensor technology of a simple electrode structure using ICEO convective fluid flow around floating conductors could offer exciting opportunities for diffusion-limited on-chip bio-microfluidic sensors.
Collapse
Affiliation(s)
- Qingming Hu
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
- School of Mechatronics Engineering, Qiqihar University, Wenhua Street 42, Qiqihar 161006, Heilongjiang, China.
| | - Yukun Ren
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
| | - Weiyu Liu
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
- School of Electronics and Control Engineering, Chang'an University, Middle-section of Nan'erHuan Road, Xi'an 710064, Shaanxi, China.
| | - Ye Tao
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
| | - Hongyuan Jiang
- School of Mechatronics Engineering, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin 150001, Heilongjiang, China.
| |
Collapse
|
36
|
Fluid Flow and Mixing Induced by AC Continuous Electrowetting of Liquid Metal Droplet. MICROMACHINES 2017. [PMCID: PMC6190310 DOI: 10.3390/mi8040119] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this work, we proposed a novel design of a microfluidic mixer utilizing the amplified Marangoni chaotic advection induced by alternating current (AC) continuous electrowetting of a metal droplet situated in electrolyte solution, due to the linear and quadratic voltage-dependence of flow velocity at small or large voltages, respectively. Unlike previous researchers exploiting the unidirectional surface stress with direct current (DC) bias at droplet/medium interface for pumping of electrolytes where the resulting flow rate is linearly proportional to the field intensity, dominance of another kind of dipolar flow pattern caused by local Marangoni stress at the drop surface in a sufficiently intense AC electric field is demonstrated by both theoretical analysis and experimental observation, which exhibits a quadratic growth trend as a function of the applied voltage. The dipolar shear stress merely appears at larger voltages and greatly enhances the mixing performance by inducing chaotic advection between the neighboring laminar flow. The mixer design developed herein, on the basis of amplified Marangoni chaotic advection around a liquid metal droplet at larger AC voltages, has great potential for chemical reaction and microelectromechanical systems (MEMS) actuator applications because of generating high-throughput and excellent mixing performance at the same time.
Collapse
|