1
|
Sathishkumar N, Toley BJ. Direct comparison of colorimetric signal amplification techniques in lateral flow immunoassays. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:7200-7209. [PMID: 39315859 DOI: 10.1039/d4ay01416b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/25/2024]
Abstract
The lateral flow immunoassay (LFIA) is widely adopted for point-of-care testing, but its limit of detection (LoD) falls short of that of laboratory-based immunoassays. Several techniques have been proposed to enhance the LoD of LFIAs using visual colorimetric readouts, yet a direct comparison of the LoDs achieved by these techniques has not been performed. In this work, we measure the LoDs of LFIAs designed for the detection of a malaria protein, PfHRP2, using four different colorimetric signal generation techniques: (i) AuNP(40 nm)-tagged detection antibodies (base case), (ii) AuNP-based enhancement of AuNP(40 nm) signal, (iii) oxidation of chloronaphthol/diaminobenzidine (CN/DAB) using HRP-tagged detection antibodies, and (iv) oxidation of CN/DAB using polyHRP(400)-tagged detection antibodies. The LoDs and the 95% confidence intervals of the LoDs achieved by the 4 techniques were 19.34 (13.37-27.62) ng mL-1, 9.57 (6.76-13.28) ng mL-1, 21.57 (14.26-32.18) ng mL-1, and 6.09 (2.23-13.47) ng mL-1, respectively. Contrary to popular perception, enzymatic signal generation using HRP-tagged detection antibodies did not improve the LoD compared to the base case of AuNP-based signal generation. Further studies revealed that the very high extinction coefficient of gold nanoparticles renders them an excellent choice for colorimetric detection, surpassing the performance of enzymatic signal generation using HRP-tagged antibodies. However, enzymatic signal generation using polyHRP-tagged antibodies improved the LoD compared to the base case. These results show that enzymatic signal amplification should not be a priori assumed to be superior to AuNP-based signal generation; and provide a reference point to LFIA developers to select an appropriate signal generation modality.
Collapse
Affiliation(s)
- N Sathishkumar
- Department of Chemical Engineering, Indian Institute of Science, Malleswaram, Bengaluru, Karnataka 560012, India.
| | - Bhushan J Toley
- Department of Chemical Engineering, Indian Institute of Science, Malleswaram, Bengaluru, Karnataka 560012, India.
- Department of Bioengineering, Indian Institute of Science, Bengaluru, Karnataka 560012, India
| |
Collapse
|
2
|
Kakkar S, Gupta P, Singh Yadav SP, Raj D, Singh G, Chauhan S, Mishra MK, Martín-Ortega E, Chiussi S, Kant K. Lateral flow assays: Progress and evolution of recent trends in point-of-care applications. Mater Today Bio 2024; 28:101188. [PMID: 39221210 PMCID: PMC11364909 DOI: 10.1016/j.mtbio.2024.101188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 07/20/2024] [Accepted: 08/05/2024] [Indexed: 09/04/2024] Open
Abstract
Paper based point-of-care (PoC) detection platforms applying lateral flow assays (LFAs) have gained paramount approval in the diagnostic domain as well as in environmental applications owing to their ease of utility, low cost, and rapid signal readout. It has centralized the aspect of self-evaluation exhibiting promising potential in the last global pandemic era of Covid-19 implementing rapid management of public health in remote areas. In this perspective, the present review is focused towards landscaping the current framework of LFAs along with integration of components and characteristics for improving the assay by pushing the detection limits. The review highlights the synergistic aspects of assay designing, sample enrichment strategies, novel nanomaterials-based signal transducers, and high-end analytical techniques that contribute significantly towards sensitivity and specificity enhancement. Various recent studies are discussed supporting the innovations in LFA systems that focus upon the accuracy and reliability of rapid PoC testing. The review also provides a comprehensive overview of all the possible difficulties in commercialization of LFAs subjecting its applicability to pathogen surveillance, water and food testing, disease diagnostics, as well as to agriculture and environmental issues.
Collapse
Affiliation(s)
- Saloni Kakkar
- Council of Scientific and Industrial Research (CSIR)- Centre for Cellular & Molecular Biology (CCMB), Hyderabad, 500007, India
| | - Payal Gupta
- Department of Biotechnology, Graphic Era (Deemed to be University), Dehradun, 248002, India
| | - Shiv Pratap Singh Yadav
- Council of Scientific and Industrial Research (CSIR)- Centre for Cellular & Molecular Biology (CCMB), Hyderabad, 500007, India
| | - Divakar Raj
- Department of Allied Sciences, School of Health Sciences and Technology, UPES, Dehradun, 248007, India
| | - Garima Singh
- Department of Allied Sciences, School of Health Sciences and Technology, UPES, Dehradun, 248007, India
| | - Sakshi Chauhan
- Dept. of Cardiothoracic and Vascular Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | | | - Elena Martín-Ortega
- IFCAE, Research Institute of Physics and Aerospace Science, Universidade de Vigo, Ourense, 32004, Spain
| | - Stefano Chiussi
- CINTECX, Universidade de Vigo, New Materials Group, Vigo, 36310, Spain
| | - Krishna Kant
- CINBIO, Universidade de Vigo, Campus Universitario As Lagoas Marcosende, Vigo, 36310, Spain
- Department of Biotechnology, School of Engineering and Applied Sciences, Bennett University, Greater Noida, U.P., India
| |
Collapse
|
3
|
Strohmaier-Nguyen D, Horn C, Baeumner AJ. Innovations in one-step point-of-care testing within microfluidics and lateral flow assays for shaping the future of healthcare. Biosens Bioelectron 2024; 267:116795. [PMID: 39332251 DOI: 10.1016/j.bios.2024.116795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 08/31/2024] [Accepted: 09/17/2024] [Indexed: 09/29/2024]
Abstract
Point-of-care testing (POCT) technology, using lateral flow assays and microfluidic systems, facilitates cost-effective diagnosis, timely treatment, ongoing monitoring, and prevention of life-threatening outcomes. Aside from significant advancements demonstrated in academic research, implementation in real-world applications remains frustratingly limited. The divergence between academic developments and practical utility is often due to factors such as operational complexity, low sensitivity and the need for trained personnel. Taking this into consideration, our objective is to present a critical and objective overview of the latest advancements in fully integrated one-step POCT assays for home-testing which would be commercially viable. In particular, aspects of signal amplification, assay design modification, and sample preparation are critically evaluated and their features and medical applications along with future perspective and challenges with respect to minimal user intervention are summarized. Associated with and very important for the one-step POCT realization are also readout devices and fabrication processes. Critical analysis of available and useful technologies are presented in the SI section.
Collapse
Affiliation(s)
- Dan Strohmaier-Nguyen
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany
| | - Carina Horn
- Roche Diagnostics GmbH, 68305, Mannheim, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany.
| |
Collapse
|
4
|
Wang MW, Chen ZM, Hsieh YC, Su YK, Lin CY, Yang SM, Li BR, Chan YH. Trimodal Multiplexed Lateral Flow Test Strips Assisted with a Portable Microfluidic Centrifugation Device. Anal Chem 2024. [PMID: 39276068 PMCID: PMC11428082 DOI: 10.1021/acs.analchem.4c02432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/16/2024]
Abstract
During the COVID-19 pandemic, the use of lateral flow assays (LFAs) expanded significantly, offering testing beyond traditional health care. Their appeal lies in the ease of use, affordability, and quick results. However, LFAs often have lower sensitivity and specificity compared with ELISA and PCR tests. Efforts to improve LFAs have increased detection times and complexity, limiting their use in large-scale point-of-care settings. To address this, we propose a novel approach using probes that generate multiple signals to enhance the sensitivity and selectivity. This concept also allows multiplexed LFAs to detect multiple analytes concurrently. We developed a trimodal probe that integrates fluorescence, color, and magnetism into a single nanohybrid. The strong plasmonic absorption and high fluorescence of Au nanoparticles and polymer dots enable qualitative and semiquantitative diagnosis, while the magnetic signal facilitates accurate quantitative measurements. As proof-of-concept targets, we selected CYFRA 21-1 and CA15-3, biomarkers for lung and breast cancer, respectively. This trimodal LFA demonstrated a remarkable detection limit of 0.26 ng/mL for CYFRA 21-1 and 2.8 U/mL for CA15-3. To the best of our knowledge, this is the first platform of a trimodal LFA with multiplexing ability. The platform's accuracy and reliability were validated using clinical serum samples, showing excellent consistency with electrochemiluminescence immunoassay results. This universal concept can be applied to other targets, paving the way for the next-generation LFAs.
Collapse
Affiliation(s)
- Man-Wen Wang
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Zong-Min Chen
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Yung-Chun Hsieh
- Department of Surgery, National Taiwan University Hospital, Hsinchu Branch, Hsinchu 30010, Taiwan
| | - Yi-Kai Su
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Chun-Yi Lin
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Shun-Mao Yang
- Department of Surgery, National Taiwan University Hospital, Hsinchu Branch, Hsinchu 30010, Taiwan
| | - Bor-Ran Li
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Yang-Hsiang Chan
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
- Center for Emergent Functional Matter Science, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| |
Collapse
|
5
|
Zha Y, Li Y, Zhou J, Liu X, Park KS, Zhou Y. Dual-Mode Fluorescent/Intelligent Lateral Flow Immunoassay Based on Machine Learning Algorithm for Ultrasensitive Analysis of Chloroacetamide Herbicides. Anal Chem 2024; 96:12197-12204. [PMID: 38990191 DOI: 10.1021/acs.analchem.4c02500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/12/2024]
Abstract
Given the harmful effect of pesticide residues, it is essential to develop portable and accurate biosensors for the analysis of pesticides in agricultural products. In this paper, we demonstrated a dual-mode fluorescent/intelligent (DM-f/DM-i) lateral flow immunoassay (LFIA) for chloroacetamide herbicides, which utilized horseradish peroxidase-IgG conjugated time-resolved fluorescent nanoparticle probes as both a signal label and amplification tool. With the newly developed LFIA in the DM-f mode, the limits of detection (LODs) were 0.08 ng/mL of acetochlor, 0.29 ng/mL of metolachlor, 0.51 ng/mL of Propisochlor, and 0.13 ng/mL of their mixture. In the DM-i mode, machine learning (ML) algorithms were used for image segmentation, feature extraction, and correlation analysis to obtain multivariate fitted equations, which had high reliability in the regression model with R2 of 0.95 in the range of 2 × 102-2 × 105 pg/mL. Importantly, the practical applicability was successfully validated by determining chloroacetamide herbicides in the corn sample with good recovery rates (85.4 to 109.3%) that correlate well with the regression model. The newly developed dual-mode LFIA with reduced detection time (12 min) holds great potential for pesticide monitoring in equipment-limited environments using a portable test strip reader and laboratory conditions using ML algorithms.
Collapse
Affiliation(s)
- Yonghong Zha
- State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Key Laboratory for Zoonosis Research of the Ministry of Education, Institute of Zoonosis, and College of Veterinary Medicine, Jilin University, Changchun 130062, China
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China
| | - Yansong Li
- State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Key Laboratory for Zoonosis Research of the Ministry of Education, Institute of Zoonosis, and College of Veterinary Medicine, Jilin University, Changchun 130062, China
| | - Jianhua Zhou
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen 518107, China
| | - Xiaolan Liu
- Shenzhen Media Digital Technology Co. Ltd, Shenzhen 518038, China
| | - Ki Soo Park
- Department of Biological Engineering, Konkuk University, Seoul 05029, Republic of Korea
| | - Yu Zhou
- State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Key Laboratory for Zoonosis Research of the Ministry of Education, Institute of Zoonosis, and College of Veterinary Medicine, Jilin University, Changchun 130062, China
- College of Animal Science and Technology, Yangtze University, Jingzhou 434025, China
| |
Collapse
|
6
|
Kourentzi K, Brosamer K, Vu B, Willson RC. Accelerated Development of a COVID-19 Lateral Flow Test in an Academic Setting: Lessons Learned. Acc Chem Res 2024; 57:1372-1383. [PMID: 38590049 PMCID: PMC11080997 DOI: 10.1021/acs.accounts.4c00075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 03/26/2024] [Accepted: 03/29/2024] [Indexed: 04/10/2024]
Abstract
The COVID-19 pandemic further demonstrated the need for usable, reliable, and cost-effective point-of-care diagnostics that can be broadly deployed, ideally for self-testing at home. Antigen tests using more-detectable reporter labels (usually at the cost of reader complexity) achieve better diagnostic sensitivity, supporting the value of higher-analytical-sensitivity reporter technologies in lateral flow.We developed a new approach to simple, inexpensive lateral flow assays (LFAs) of great sensitivity, based on the glow stick peroxyoxalate chemistry widely used in emergency settings and in children's toys. At the peak of the COVID-19 pandemic, we had the opportunity to participate in the pandemic-driven NIH Rapid Acceleration of Diagnostics (RADx) initiative aiming to develop a deployable lateral flow diagnostic for SARS-CoV-2 nucleoprotein based on our novel glow stick-inspired light-emitting reporter technology. During this project, we screened more than 250 antibody pairs for analytical sensitivity and specificity directly in LFA format, using recombinant nucleoprotein and then gamma-irradiated virions spiked into negative nasal swab extracts. Membranes and other LFA materials and swabs and extraction reagent components also were screened and selected. Optimization of conjugate preparation and spraying as well as pretreatment/conditioning of the sample pad led to the final optimized LFA strip. Technology development also included optimization of excitation liquid enclosed in disposable droppers, design of a custom cartridge and smartphone-based reader, and app development, even a prototype reader usable with any mobile phone. Excellent preclinical performance was first demonstrated with contrived samples and then with leftover clinical samples. Moving beyond traditional academic focus areas, we were able to establish a quality management system (QMS), produce large numbers of customized LFA cassettes by contract injection molding, build in-house facilities to assemble and store thousands of complete tests for verification and validation and usability studies, and source kitting/packaging services and quality standard reagents and build partnerships for clinical translation, regulatory guidance, scale up, and market deployment. We were not able to bring this early stage technology to the point of commercialization within the limited time and resources available, but we did achieve strong proof-of-concept and advance translational aspects of the platform including initial high-performance LFAs, reading by the iPhone app using only a $2 plastic dark box with no lens, and convenient, usable excitation liquid packaging in droppers manufacturable in very large numbers.In this Account, we aim to provide a concise overview of our 18-month sprint toward the practical development of a deployable antigen lateral flow assay under pandemic conditions and the challenges and successes experienced by our team. We highlight what it takes to coach a technically savvy but commercially inexperienced academic team through the accelerated translation of an early stage technology into a useful product. Finally, we provide a guided tutorial and workflow to empower others interested in the rapid development of translatable LFAs.
Collapse
Affiliation(s)
- Katerina Kourentzi
- William
A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77004, United States
| | - Kristen Brosamer
- Department
of Biomedical Engineering, University of
Houston, Houston, Texas 77004, United States
| | - Binh Vu
- William
A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77004, United States
| | - Richard C. Willson
- William
A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77004, United States
- Department
of Biomedical Engineering, University of
Houston, Houston, Texas 77004, United States
- Department
of Biology and Biochemistry, University
of Houston, Houston, Texas 77004, United States
- Escuela
de Medicina y Ciencias de Salud, Tecnológico
de Monterrey, 64849 Monterrey, Nuevo León, México
| |
Collapse
|
7
|
Li J, Zhang P, Xu Q, Nie Y, Shao S, Wang Z, Jiang Y. Preparation of dyed polymer microspheres by a physical-chemical dual-binding method and their application in lateral flow immunoassay. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2033-2043. [PMID: 38497428 DOI: 10.1039/d3ay02279j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/19/2024]
Abstract
Lateral flow immunoassay (LFIA) has shown great competitiveness in point-of-care testing due to its flexibility and simplicity. Dyed polymer microspheres are one of the most widely used marker particles for signal presentation as they are very convenient for visual interpretation, which is one of the most attractive features of LFIA. The color intensity, as the most critical factor, is directly related to the visual effect. In this work, a physical-chemical dual-binding strategy was proposed for the preparation of functionalized dyed microspheres. Bifunctional seed microspheres were synthesized by introducing 4-vinylbenzyl chloride (VBC) into the soap-free emulsion polymerization process, and the effective immobilization of dyes inside and on the surface of the polymer microspheres was achieved by covalent bonding and swelling methods. The microspheres were characterized by SEM, FT-IR spectroscopy and UV-vis spectroscopy. The results showed that the microspheres containing VBC were spherical with an average particle size of 300 nm. When the microspheres were prepared by adding 10 wt% VBC relative to the total monomer, the immobilization amount of 1-[[4-[(dimethylphenyl)azo]dimethyl phenyl]azo]-2-naphthol (Red-27) was increased to 180 mg g-1, which was 1.8 times that of the microspheres without VBC. The resulting nanomaterials were successfully used to establish a lateral flow immunoassay for the detection of COVID-19 virus N protein. The linear response concentration range was 2.64-87.84 COI, and the detection limit was 14.95 COI.
Collapse
Affiliation(s)
- Jiatong Li
- Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, School of Chemistry and Chemical Engineering, Southeast University, China.
| | - Pengfei Zhang
- Getein Biotechnology Co., Ltd., Nanjing 210000, PR China
| | - Qianrui Xu
- Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, School of Chemistry and Chemical Engineering, Southeast University, China.
| | - Yingrui Nie
- Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, School of Chemistry and Chemical Engineering, Southeast University, China.
| | - Shimin Shao
- Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, School of Chemistry and Chemical Engineering, Southeast University, China.
| | - Zhifei Wang
- Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, School of Chemistry and Chemical Engineering, Southeast University, China.
| | - Yong Jiang
- Jiangsu Province Hi-Tech Key Laboratory for Biomedical Research, School of Chemistry and Chemical Engineering, Southeast University, China.
| |
Collapse
|
8
|
Wang X, Huang H, Zhong S, Shentu X, Ye Z, Yu X. Carboxymethyl chitosan-modified UiO-66 for the rapid detection of fenpropathrin in grains. Int J Biol Macromol 2024; 265:131032. [PMID: 38521295 DOI: 10.1016/j.ijbiomac.2024.131032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 03/15/2024] [Accepted: 03/19/2024] [Indexed: 03/25/2024]
Abstract
Fenpropathrin residues in grain are potentially harmful to humans. Therefore, a fluorimetric lateral flow immunoassay using a zirconium-based organic skeleton (UiO-66) as a signal marker was developed for detecting fenpropathrin. Herein, carboxymethyl chitosan (CMCS) was used to modify UiO-66 and improve its water solubility to facilitate stable binding with sodium fluorescein (NaFL). This resulted in formation of a new fluorescent probe that is more suitable for lateral flow immunoassay (LFIA). The materials were characterized via electron microscopy, Fourier-transform infrared spectroscopy, and powder X-ray diffraction. CMCS and NaFL were successfully bound to UiO-66. Under optimized conditions, the constructed NaFL/UiO-66@CMCS-LFIA exhibited a good linear relationship within the range of 0.98-62.5 μg/L, with a detection limit of 3.91 μg/L. This probe was fourfold more sensitive than traditional colloidal gold nanoparticle-based LFIA. Finally, NaFL/UiO-66@CMCS-LFIA was successfully applied to detect fenpropathrin in wheat and maize samples. The detection limit was 1.56 μg/kg and recoveries ranged from 96.58 % to 118.56 %. This study provides a sensitive, stable, and convenient method for the rapid detection of pesticide residues.
Collapse
Affiliation(s)
- Xiaoyao Wang
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection and Quarantine, China Jiliang University, Hangzhou 310018, Zhejiang, People's Republic of China
| | - Haizhi Huang
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection and Quarantine, China Jiliang University, Hangzhou 310018, Zhejiang, People's Republic of China.
| | - Siyao Zhong
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection and Quarantine, China Jiliang University, Hangzhou 310018, Zhejiang, People's Republic of China
| | - Xuping Shentu
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection and Quarantine, China Jiliang University, Hangzhou 310018, Zhejiang, People's Republic of China
| | - Zihong Ye
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection and Quarantine, China Jiliang University, Hangzhou 310018, Zhejiang, People's Republic of China
| | - Xiaoping Yu
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection and Quarantine, China Jiliang University, Hangzhou 310018, Zhejiang, People's Republic of China.
| |
Collapse
|
9
|
Gui Y, Zhao Y, Liu P, Wang Y, Mao X, Peng C, Hammock BD, Zhang C. Colorimetric and Reverse Fluorescence Dual-Signal Readout Immunochromatographic Assay for the Sensitive Determination of Sibutramine. ACS OMEGA 2024; 9:7075-7084. [PMID: 38371773 PMCID: PMC10870287 DOI: 10.1021/acsomega.3c09050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/24/2023] [Accepted: 01/15/2024] [Indexed: 02/20/2024]
Abstract
Later flow immunochromatographic assay has been widely used in clinical, environmental, and other diagnostic applications owing to its high sensitivity and throughput. However, most immunoassays operate in the "turn-off" mode for detecting targets of low molecular weight. The signal intensity decreases as the analyte concentration increases, which poses a challenge for achieving ultrasensitive detection at low concentrations and is counterintuitive to new users. In this work, a fluorometric immunochromatographic assay (FICA) is developed to simultaneously read "turn-on" fluorescent and "turn-off" colorimetric signals, where ZnCdSe/ZnS quantum dots act as fluorescence donors and gold nanoparticles (AuNPs) act as quenchers. The fluorescent signal (excitation/emission wavelengths of 365/525 nm) is positively correlated with analytes' concentration. Taking sibutramine (SBT) as the analysis target, the visual limit of detection for SBT reached 3.9 ng/mL, and the limit of Quantitation was 5.0 ng/mg in spiked samples. The developed FICA achieves a high sensitivity in SBT detection, which is much lower than that of the colloidal gold-based immunochromatographic assay. This dual-function detection mode has great potential to be used as a rapid on-site semiquantitative method, providing an alternative mode for the determination of low levels of target analytes.
Collapse
Affiliation(s)
- Yun Gui
- State
Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- Jiangsu
Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation
Base of Ministry of Science and Technology, Institute of Food Safety
and Nutrition, Jiangsu Academy of Agricultural
Sciences, Nanjing 210014, P. R. China
| | - Yun Zhao
- Jiangsu
Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation
Base of Ministry of Science and Technology, Institute of Food Safety
and Nutrition, Jiangsu Academy of Agricultural
Sciences, Nanjing 210014, P. R. China
- State
Key Lab of Food Science and Technology, Jiangnan University, Wuxi 214122, P. R. China
| | - Pengyan Liu
- Jiangsu
Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation
Base of Ministry of Science and Technology, Institute of Food Safety
and Nutrition, Jiangsu Academy of Agricultural
Sciences, Nanjing 210014, P. R. China
| | - Yulong Wang
- Jiangsu
Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation
Base of Ministry of Science and Technology, Institute of Food Safety
and Nutrition, Jiangsu Academy of Agricultural
Sciences, Nanjing 210014, P. R. China
| | - Xinxin Mao
- Jiangsu
Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation
Base of Ministry of Science and Technology, Institute of Food Safety
and Nutrition, Jiangsu Academy of Agricultural
Sciences, Nanjing 210014, P. R. China
- College
of Plant Protection, Nanjing Agricultural
University, Nanjing 210095, P. R. China
| | - Chifang Peng
- State
Key Lab of Food Science and Technology, Jiangnan University, Wuxi 214122, P. R. China
| | - Bruce D. Hammock
- Department
of Entomology and Nematology and UCD Comprehensive Cancer Center, University of California, Davis, California 95616, United States
| | - Cunzheng Zhang
- State
Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, P. R. China
- Jiangsu
Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation
Base of Ministry of Science and Technology, Institute of Food Safety
and Nutrition, Jiangsu Academy of Agricultural
Sciences, Nanjing 210014, P. R. China
- College
of Plant Protection, Nanjing Agricultural
University, Nanjing 210095, P. R. China
| |
Collapse
|
10
|
Yu Q, Wu T, Tian B, Li J, Liu Y, Wu Z, Jin X, Wang C, Wang C, Gu B. Recent advances in SERS-based immunochromatographic assay for pathogenic microorganism diagnosis: A review. Anal Chim Acta 2024; 1286:341931. [PMID: 38049231 DOI: 10.1016/j.aca.2023.341931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/02/2023] [Accepted: 10/17/2023] [Indexed: 12/06/2023]
Abstract
Infectious diseases caused by bacteria, viruses, fungi, and other pathogenic microorganisms are among the most harmful public health problems in the world, causing tens of millions of deaths and incalculable economic losses every year. The establishment of rapid, simple, and highly sensitive diagnostic methods for pathogenic microorganisms is important for the prevention and control of infectious diseases, guidance of timely treatment, and the reduction of public safety risks. Lateral flow immunoassay (LFA) based on the colorimetric signal of colloidal gold is the most popular point-of-care testing technology at present, but it is limited by poor sensitivity and low throughput and hardly meets the needs of the highly sensitive screening of pathogenic microorganisms. In recent years, the combination of surface-enhanced Raman scattering (SERS) and LFA technology has developed into a novel analytical platform with high sensitivity and multiple detection capabilities and has shown great advantages in the detection of pathogenic microorganisms and infectious diseases. This review summarizes the working principle, design ideas, and application of the existing SERS-based LFA methods in pathogenic microorganism detection and further introduces the effect of new technologies such as Raman signal encoding, magnetic enrichment, novel membrane nanotags, and integrated Raman reading equipment on the performance of SERS-LFA. Finally, the main challenges and the future direction of development in this field of SERS-LFA are discussed.
Collapse
Affiliation(s)
- Qing Yu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, China
| | - Ting Wu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Benshun Tian
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Jiaxuan Li
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Yun Liu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Zelan Wu
- Guangzhou Labway Clinical Laboratory Co., Ltd, Guangdong, 510000, China
| | - Xiong Jin
- Guangzhou Labway Clinical Laboratory Co., Ltd, Guangdong, 510000, China
| | - Chaoguang Wang
- College of Intelligence Science and Technology, National University of Defense Technology, Changsha, 410073, China.
| | - Chongwen Wang
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, China.
| | - Bing Gu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China.
| |
Collapse
|
11
|
Zhang Y. 3D Printing for Cancer Diagnosis: What Unique Advantages Are Gained? ACS MATERIALS AU 2023; 3:620-635. [PMID: 38089653 PMCID: PMC10636786 DOI: 10.1021/acsmaterialsau.3c00046] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 08/19/2023] [Accepted: 08/21/2023] [Indexed: 09/20/2024]
Abstract
Cancer is a complex disease with global significance, necessitating continuous advancements in diagnostics and treatment. 3D printing technology has emerged as a revolutionary tool in cancer diagnostics, offering immense potential in detection and monitoring. Traditional diagnostic methods have limitations in providing molecular and genetic tumor information that is crucial for personalized treatment decisions. Biomarkers have become invaluable in cancer diagnostics, but their detection often requires specialized facilities and resources. 3D printing technology enables the fabrication of customized sensor arrays, enhancing the detection of multiple biomarkers specific to different types of cancer. These 3D-printed arrays offer improved sensitivity, allowing the detection of low levels of biomarkers, even in complex samples. Moreover, their specificity can be fine-tuned, reducing false-positive and false-negative results. The streamlined and cost-effective fabrication process of 3D printing makes these sensor arrays accessible, potentially improving cancer diagnostics on a global scale. By harnessing 3D printing, researchers and clinicians can enhance early detection, monitor treatment response, and improve patient outcomes. The integration of 3D printing in cancer diagnostics holds significant promise for the future of personalized cancer care.
Collapse
Affiliation(s)
- Yu Zhang
- Division
of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, The University of Texas at Austin, Austin, Texas 78705, United States
- Pharmaceutics
and Drug Delivery, School of Pharmacy, The
University of Mississippi, Oxford, Mississippi 38677-1848, United States
| |
Collapse
|
12
|
Natarajan S, Priye A. Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification. MICROMACHINES 2023; 14:1993. [PMID: 38004850 PMCID: PMC10673117 DOI: 10.3390/mi14111993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 10/22/2023] [Accepted: 10/24/2023] [Indexed: 11/26/2023]
Abstract
Accurate quantification of immunoglobulin G (IgG) levels is vital for understanding immune status and diagnosing various medical conditions. Lateral flow assays (LFAs) offer rapid and convenient diagnostic tools, but their sensitivity has been a limitation. Our research introduces a refined method incorporating europium nanoparticles, enhancing both sensitivity and accuracy of LFAs in human IgG measurement. Utilizing a unique sandwich format, carboxylate-modified polystyrene Eu (III) chelate microparticles (CM-EUs) acted as the primary reporters. The concentrations of both detection and capture antibodies on the strip were optimized to bolster the LFA's quantitative performance. The subsequent calibration curve between the IgG concentration and the measured intensity ratio (VR) established the linearity and analytical sensitivity of our method with a high correlation coefficient (r = 0.99) and an impressively low limit of detection (LoD = 0.04 ng/mL). Our precision assessment, segmented into intra-assay and inter-assay evaluations, showcases the method's consistency and reproducibility. The LFA assay's stability was established by demonstrating its resistance to degradation and affirming its potential for extended storage without a dip in performance. The study's findings underscore the potential of this method to contribute to diagnostic medicine and improve patient care.
Collapse
Affiliation(s)
- Satheesh Natarajan
- Healthcare Technology Innovation Center, Indian Institute of Technology, Chennai 600113, India;
| | - Aashish Priye
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
- Digital Futures, University of Cincinnati, Cincinnati, OH 45221, USA
| |
Collapse
|
13
|
Sun Q, Ning Q, Li T, Jiang Q, Feng S, Tang N, Cui D, Wang K. Immunochromatographic enhancement strategy for SARS-CoV-2 detection based on nanotechnology. NANOSCALE 2023; 15:15092-15107. [PMID: 37676509 DOI: 10.1039/d3nr02396f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
The global outbreak of coronavirus disease 2019 (COVID-19) has been catastrophic to both human health and social development. Therefore, developing highly reliable and sensitive point-of-care testing (POCT) for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has become a priority. Among all available POCTs, the lateral flow immunoassay (LFIA, also known as immunochromatography) has proved to be effective due to its accuracy, portability, convenience, and speed. In areas with a scarcity of laboratory resources and medical personnel, the LFIA provides an affordable option for the diagnosis of COVID-19. This review offers a comprehensive overview of methods for improving the sensitivity of SARS-CoV-2 detection using immunochromatography based on nanotechnology, sorted according to the different detection targets (antigens, antibodies, and nucleic acids). It also looks into the performance and properties of the various sensitivity enhancement strategies, before delving into the remaining challenges in COVID-19 diagnosis through LFIA. Ultimately, it seeks to provide helpful guidance in selecting an appropriate strategy for SARS-CoV-2 immunochromatographic detection based on nanotechnology.
Collapse
Affiliation(s)
- Qingwen Sun
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai, 200240, China.
| | - Qihong Ning
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai, 200240, China.
| | - Tangan Li
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai, 200240, China.
| | - Qixia Jiang
- Department of Cardiology, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, 1111 XianXia Road, Shanghai, 200336, China
| | - Shaoqing Feng
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, 200011, China
| | - Ning Tang
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai, 200240, China.
| | - Daxiang Cui
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai, 200240, China.
| | - Kan Wang
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai, 200240, China.
| |
Collapse
|
14
|
Panferov VG, Zherdev AV, Dzantiev BB. Post-Assay Chemical Enhancement for Highly Sensitive Lateral Flow Immunoassays: A Critical Review. BIOSENSORS 2023; 13:866. [PMID: 37754100 PMCID: PMC10526817 DOI: 10.3390/bios13090866] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/15/2023] [Accepted: 08/23/2023] [Indexed: 09/28/2023]
Abstract
Lateral flow immunoassay (LFIA) has found a broad application for testing in point-of-care (POC) settings. LFIA is performed using test strips-fully integrated multimembrane assemblies containing all reagents for assay performance. Migration of liquid sample along the test strip initiates the formation of labeled immunocomplexes, which are detected visually or instrumentally. The tradeoff of LFIA's rapidity and user-friendliness is its relatively low sensitivity (high limit of detection), which restricts its applicability for detecting low-abundant targets. An increase in LFIA's sensitivity has attracted many efforts and is often considered one of the primary directions in developing immunochemical POC assays. Post-assay enhancements based on chemical reactions facilitate high sensitivity. In this critical review, we explain the performance of post-assay chemical enhancements, discuss their advantages, limitations, compared limit of detection (LOD) improvements, and required time for the enhancement procedures. We raise concerns about the performance of enhanced LFIA and discuss the bottlenecks in the existing experiments. Finally, we suggest the experimental workflow for step-by-step development and validation of enhanced LFIA. This review summarizes the state-of-art of LFIA with chemical enhancement, offers ways to overcome existing limitations, and discusses future outlooks for highly sensitive testing in POC conditions.
Collapse
Affiliation(s)
- Vasily G. Panferov
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
- Department of Chemistry, York University, Toronto, ON M3J 1P3, Canada
| | - Anatoly V. Zherdev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
| | - Boris B. Dzantiev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
| |
Collapse
|
15
|
Chen YC, Syu YH, Huang JY, Lin CY, Chan YH. Hybrid polymer dot-magnetic nanoparticle based immunoassay for dual-mode multiplexed detection of two mycotoxins. Chem Commun (Camb) 2023; 59:9968-9971. [PMID: 37501643 DOI: 10.1039/d3cc02586a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
We designed polymer dot-magnetic nanoparticle nanohybrids for signal enhancement in a test strip platform. Besides, the multicolor emissions of the Pdots embed multiplexing ability for this test strip. Two mycotoxins, aflatoxin B1 and zearalenone, were tested with the determined limits of detection of 2.15 ng mL-1 and 4.87 ng mL-1, respectively.
Collapse
Affiliation(s)
- Yi-Chen Chen
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
| | - Yu-Han Syu
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
| | - Jhen-Yan Huang
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
| | - Chun-Yi Lin
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
| | - Yang-Hsiang Chan
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
- Center for Emergent Functional Matter Science, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, 80708, Taiwan
| |
Collapse
|
16
|
Brosamer K, Kourentzi K, Willson RC, Vu BV. Glowstick-inspired smartphone-readable reporters for sensitive, multiplexed lateral flow immunoassays. COMMUNICATIONS ENGINEERING 2023; 2:31. [PMID: 38586601 PMCID: PMC10955955 DOI: 10.1038/s44172-023-00075-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 04/25/2023] [Indexed: 04/09/2024]
Abstract
The COVID-19 pandemic has increased demand for point-of-care (POC) screening tests such as lateral flow assays (LFAs) and highlighted the need for sensitive and cost-effective POC diagnostic platforms. Here, we demonstrate an LFA platform using standard fluorescent nanoparticle reporters in which optical excitation is replaced by chemical excitation using the peroxyoxalate-based chemistry of inexpensive, shelf-stable glowsticks. The one-step chemi-excitation of fluorescent particles produces visible light readable by an unmodified smartphone, enhancing sensitivity while preserving simplicity and cost-effectiveness. Our Glow LFA detected the common model analyte human chorionic gonadotropin with a limit of detection (LoD) of 39 pg/mL-over ten times more sensitive than standard gold nanoparticles using the same antibodies. We also demonstrate its application to the detection of SARS-CoV-2 nucleoprotein at 100 pg/mL in nasal swab extract. Multiple fluorescent dyes can be chemi-excited by a single reagent, allowing for color multiplexing on a single LFA strip with a smartphone camera. The detection of three analytes on a single LFA test line was demonstrated using red, green, and blue fluorescent reporter particles, making glow LFA a promising platform for multiplexed detection.
Collapse
Affiliation(s)
- Kristen Brosamer
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Katerina Kourentzi
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
| | - Richard C. Willson
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
- Escuela de Medicina y Ciencias de Salud, Tecnológico de Monterrey, Monterrey, Nuevo León 64710, Mexico
| | - Binh V. Vu
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
| |
Collapse
|
17
|
Liu Z, Yang Y, Zhao X, Wang T, He L, Nan X, Vidović D, Bai P. A universal mass tag based on polystyrene nanoparticles for single-cell multiplexing with mass cytometry. J Colloid Interface Sci 2023; 639:434-443. [PMID: 36822043 DOI: 10.1016/j.jcis.2023.02.092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 02/16/2023] [Accepted: 02/17/2023] [Indexed: 02/21/2023]
Abstract
Mass cytometry (MC) is an emerging bioanalytical technique for high-dimensional biomarkers interrogation simultaneously on individual cells. However, the sensitivity and multiplexed analysis ability of MC was highly restricted by the current metal chelating polymer (MCP) mass tags. Herein, a new design strategy for MC mass tags by using a commercial available and low cost classical material, polystyrene nanoparticle (PS-NP) to carry metals was reported. Unlike inorganic materials, sub-micron-grade metal-loaded polystyrene can be easily detected by MC, thus it is not essential to pursue extremely small particle size in this mass tag design strategy. An altered cell staining buffer can significantly lower the nonspecific binding (NSB) of non-functionalized PS-NPs, revealing another method to lower NSB beside surface modification. The metal doped PS-NP_Abs mass tags showed high compatibility with MCP mass tags and 5-fold higher sensitivity. By using Hf doped PS-NP_Abs as mass tags, four new MC detection channels (177Hf, 178Hf, 179Hf and 180Hf) were developed. In general, this work provides a new strategy in designing MC mass tags and lowering NSB, opening up possibility of introducing more potential MC mass tag candidates.
Collapse
Affiliation(s)
- Zhizhou Liu
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China; Jinan Guoke Medical Technology Development Co., Ltd, Shandong 250013, People's Republic of China.
| | - Yu Yang
- School of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, China
| | - Xiang Zhao
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China; College of Mechanics and Materials, Hohai University, 8 Focheng West Road, Nanjing, 210098, China
| | - Tong Wang
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China
| | - Liang He
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China; Jinan Guoke Medical Technology Development Co., Ltd, Shandong 250013, People's Republic of China
| | - Xueyan Nan
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China
| | - Dragoslav Vidović
- School of Chemistry, Faculty of Sciences, Monash University, 3800 Clayton, Australia
| | - Pengli Bai
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
| |
Collapse
|
18
|
Jiang H, Lv X, Li A, Peng Z, Deng Y, Li X. A dual-labeled fluorescence quenching lateral flow assay based on one-pot enzyme-free isothermal cascade amplification for the rapid and sensitive detection of pathogens. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023. [PMID: 37203352 DOI: 10.1039/d3ay00526g] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Rapid detection of nucleic acids is integral for clinical diagnostics, especially if a major public-health emergency occurs. However, such detection cannot be carried out efficiently in remote areas limited by medical resources. Herein, a dual-labeled fluorescence resonance energy transfer (FRET) lateral flow assay (LFA) based on one-pot enzyme-free cascade amplification was developed for rapid, convenient, and sensitive detection of open reading frame (ORF)1ab of severe acute respiratory syndrome-coronavirus-2. The catalyzed hairpin assembly (CHA) reaction of two well-designed hairpin probes was initiated by a target sequence and generated a hybridization chain reaction (HCR) initiator. Then, HCR probes modified with biotin were initiated to produce long DNA nanowires. After two-level amplification, the cascade-amplified product was detected by dual-labeled lateral flow strips. Gold nanoparticles (AuNPs)-streptavidin combined with the product and then ran along a nitrocellulose membrane under the action of capillary force. After binding with fluorescent microsphere-labeled-specific probes on the T line, a positive signal (red color) could be observed. Meanwhile, AuNPs could quench the fluorescence of the T line, and an inverse relationship between fluorescence intensity and the concentration of the CHA-HCR-amplified product was formed. The proposed strategy achieved a satisfactory limit of detection of 2.46 pM for colorimetric detection and 174 fM for fluorescent detection, respectively. Benefitting from the features of being one-pot, enzyme-free, low background, high sensitivity, and selectivity, this strategy shows great potential in bioanalysis and clinical diagnostics upon further development.
Collapse
Affiliation(s)
- Hao Jiang
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Xuefei Lv
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Anyi Li
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Zhao Peng
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Yulin Deng
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Xiaoqiong Li
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| |
Collapse
|
19
|
Seo SE, Ryu E, Kim J, Shin CJ, Kwon OS. Fluorophore-encapsulated nanobeads for on-site, rapid, and sensitive lateral flow assay. SENSORS AND ACTUATORS. B, CHEMICAL 2023; 381:133364. [PMID: 36684645 PMCID: PMC9838036 DOI: 10.1016/j.snb.2023.133364] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 01/12/2023] [Accepted: 01/12/2023] [Indexed: 05/09/2023]
Abstract
Since December 2019, the rapid and sensitive detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has become a priority for public health. Although the lateral flow assay (LFA) sensor has emerged as a rapid and on-site SARS-CoV-2 detection technique, the conventional approach of using gold nanoparticles for the signaling probe had limitations in increasing the sensitivity of the sensor. Herein, our newly suggested methodology to improve the performance of the LFA system could amplify the sensor signal with a facile fabrication method by concentrating fluorescent organic molecules. A large Stokes shift fluorophore (single benzene) was encapsulated into polystyrene nanobeads to enhance the fluorescence intensity of the probe for LFA sensor, which was detected on the test line with a longpass filter under ultraviolet light irradiation. This approach provides comparatively high sensitivity with the limit of detection of 1 ng mL-1 for the SARS-CoV-2 spike protein and a fast detection process, which takes less than 20 min. Furthermore, our sensor showed higher performance than gold nanoparticle-based commercial rapid diagnostics test kits in clinical tests, proving that this approach is more suitable and reliable for the sensitive and rapid detection of viruses, bacteria, and other hazardous materials.
Collapse
Key Words
- Ab, Antibody
- Ag, Antigen
- AuNP, Gold nanoparticle
- CL, Control line
- CT, Threshold cycle
- LFA, Lateral flow assay
- LOD, Limit of detection
- PCR, Polymerase chain reaction
- PS, Polystyrene
- RDT, Rapid diagnostic test
- SARS-CoV-2, Severe acute respiratory syndrome coronavirus 2
- SB, Single Benzene
- TL, Test line
Collapse
Affiliation(s)
- Sung Eun Seo
- Infectious Disease Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, South Korea
| | - Eunsu Ryu
- Infectious Disease Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, South Korea
| | - Jinyeong Kim
- Infectious Disease Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, South Korea
| | - Chan Jae Shin
- Infectious Disease Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, South Korea
- Department of Biotechnology, University of Science & Technology (UST), Daejeon 34141, South Korea
- SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon 16419, South Korea
| | - Oh Seok Kwon
- Infectious Disease Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, South Korea
- Department of Biotechnology, University of Science & Technology (UST), Daejeon 34141, South Korea
- College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, South Korea
- SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon 16419, South Korea
- Department of Nano Engineering, Sungkyunkwan University, Suwon 16419, South Korea
| |
Collapse
|
20
|
Lv Y, Fan J, Zhao M, Wu R, Li LS. Recent advances in quantum dot-based fluorescence-linked immunosorbent assays. NANOSCALE 2023; 15:5560-5578. [PMID: 36866747 DOI: 10.1039/d2nr07247e] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Fluorescence immunoassays have been given considerable attention among the quantitative detection methods in the clinical medicine and food safety testing fields. In particular, semiconductor quantum dots (QDs) have become ideal fluorescent probes for highly sensitive and multiplexed detection due to their unique photophysical properties, and the QD fluorescence-linked immunosorbent assay (FLISA) with high sensitivity, high accuracy, and high throughput has been greatly developed recently. In this manuscript, the advantages of applying QDs to FLISA platforms and some strategies for their application to in vitro diagnostics and food safety are discussed. Given the rapid development of this field, we classify these strategies based on the combination of QD types and detection targets, including traditional QDs or QD micro/nano-spheres-FLISA, and multiple FLISA platforms. In addition, some new sensors based on the QD-FLISA are introduced; this is one of the hot spots in this field. The current focus and future direction of QD-FLISA are also discussed, which provides important guidance for the further development of FLISA.
Collapse
Affiliation(s)
- Yanbing Lv
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Jinjin Fan
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Man Zhao
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Ruili Wu
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| | - Lin Song Li
- Key Lab for Special Functional Materials of the Ministry of Education, and School of Materials, Henan University, Kaifeng, 475004, China.
| |
Collapse
|
21
|
Wang Z, Guo Y, Xianyu Y. Applications of self-assembly strategies in immunoassays: A review. Coord Chem Rev 2023. [DOI: 10.1016/j.ccr.2022.214974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
22
|
Chabi M, Vu B, Brosamer K, Smith M, Chavan D, Conrad JC, Willson RC, Kourentzi K. Smartphone-read phage lateral flow assay for point-of-care detection of infection. Analyst 2023; 148:839-848. [PMID: 36645184 PMCID: PMC10503656 DOI: 10.1039/d2an01499h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
The COVID-19 pandemic has highlighted the urgent need for sensitive, affordable, and widely accessible testing at the point of care. Here we demonstrate a new, universal LFA platform technology using M13 phage conjugated with antibodies and HRP enzymes that offers high analytical sensitivity and excellent performance in a complex clinical matrix. We also report its complete integration into a sensitive chemiluminescence-based smartphone-readable lateral flow assay for the detection of SARS-CoV-2 nucleoprotein. We screened 84 anti-nucleoprotein monoclonal antibody pairs in phage LFA and identified an antibody pair that gave an LoD of 25 pg mL-1 nucleoprotein in nasal swab extract using a FluorChem gel documentation system and 100 pg mL-1 when the test was imaged and analyzed by an in-house-developed smartphone reader. The smartphone-read LFA signals for positive clinical samples tested (N = 15, with known Ct) were statistically different (p < 0.001) from signals for negative clinical samples (N = 11). The phage LFA technology combined with smartphone chemiluminescence imaging can enable the timely development of ultrasensitive, affordable point-of-care testing platforms for SARS-CoV-2 and beyond.
Collapse
Affiliation(s)
- Maede Chabi
- Department of Biomedical Engineering, University of Houston, Houston, Texas 77204, USA.
| | - Binh Vu
- Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77204, USA.
| | - Kristen Brosamer
- Department of Biomedical Engineering, University of Houston, Houston, Texas 77204, USA.
| | - Maxwell Smith
- Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77204, USA.
| | - Dimple Chavan
- Department of Biology and Biochemistry, University of Houston, Houston, Texas 77204, USA
| | - Jacinta C Conrad
- Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77204, USA.
| | - Richard C Willson
- Department of Biomedical Engineering, University of Houston, Houston, Texas 77204, USA.
- Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77204, USA.
- Department of Biology and Biochemistry, University of Houston, Houston, Texas 77204, USA
- Escuela de Medicina y Ciencias de Salud, Tecnológico de Monterrey, Monterrey, Nuevo León 64710, Mexico
| | - Katerina Kourentzi
- Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77204, USA.
| |
Collapse
|
23
|
Aggregation-Induced Red Emission Nanoparticle-Based Lateral Flow Immunoassay for Highly Sensitive Detection of Staphylococcal Enterotoxin A. Toxins (Basel) 2023; 15:toxins15020113. [PMID: 36828428 PMCID: PMC9964500 DOI: 10.3390/toxins15020113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/17/2023] [Accepted: 01/19/2023] [Indexed: 01/31/2023] Open
Abstract
Staphylococcal enterotoxin A (SEA) has presented enormous difficulties in dairy food safety and the sensitive detection of SEA provides opportunities for effective food safety controls and staphylococcal food poisoning tracebacks. Herein, a novel aggregation-induced emission (AIE)-based sandwich lateral flow immunoassay (LFIA) was introduced to detect SEA by using red-emissive AIE nanoparticles (AIENPs) as the fluorescent nanoprobe. The nanoprobe was constructed by directly immobilising antibodies on boronate-tagged AIENPs (PBA-AIENPs) via a boronate affinity reaction, which exhibited a high SEA-specific affinity and remarkable fluorescent performance. Under optimal conditions, the ultrasensitive detection of SEA in pasteurised milk was achieved within 20 min with a limit of detection of 0.04 ng mL-1. The average recoveries of the PBA-AIENP-LFIA ranged from 91.3% to 117.6% and the coefficient of variation was below 15%. It was also demonstrated that the PBA-AIENP-LFIA had an excellent selectivity against other SE serotypes. Taking advantage of the excellent sensitivity of this approach, real chicken and salad samples were further analysed, with a high versatility and accuracy. The proposed PBA-AIENP-LFIA platform shows promise as a potent tool for the identification of additional compounds in food samples as well as an ideal test method for on-site detections.
Collapse
|
24
|
Xu G, Fan X, Chen X, Liu Z, Chen G, Wei X, Li X, Leng Y, Xiong Y, Huang X. Ultrasensitive Lateral Flow Immunoassay for Fumonisin B1 Detection Using Highly Luminescent Aggregation-Induced Emission Microbeads. Toxins (Basel) 2023; 15:79. [PMID: 36668898 PMCID: PMC9861643 DOI: 10.3390/toxins15010079] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 01/05/2023] [Accepted: 01/09/2023] [Indexed: 01/18/2023] Open
Abstract
Lateral flow immunoassay (LFIA) based on fluorescent microbeads has attracted much attention for its use in rapid and accurate food safety monitoring. However, conventional fluorescent microbeads are limited by the aggregation-caused quenching effect of the loaded fluorophores, thus resulting in low signal intensity and insufficient sensitivity of fluorescent LFIA. In this study, a green-emitting fluorophore with an aggregation-induced emission (AIE) characteristic was encapsulated in polymer nanoparticles via an emulsification technique to form ultrabright fluorescent microbeads (denoted as AIEMBs). The prepared AIEMBs were then applied in a competitive LFIA (AIE-LFIA) as signal reporters for the rapid and highly sensitive screening of fumonisin B1 (FB1) in real corn samples. High sensitivity with a detection limit of 0.024 ng/mL for FB1 was achieved by the developed AIE-LFIA. Excellent selectivity, good accuracy, and high reliability of the AIE-LFIA were demonstrated, indicating a promising platform for FB1 screening.
Collapse
Affiliation(s)
- Ge Xu
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Xiaojing Fan
- School of Future Technology, Nanchang University, Nanchang 330047, China
| | - Xirui Chen
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Zilong Liu
- School of Food Science and Engineering, Hainan University, Haikou 570228, China
| | - Guoxin Chen
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Xiaxia Wei
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Xiangmin Li
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Yuankui Leng
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Xiaolin Huang
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| |
Collapse
|
25
|
Wang Y, Li Y, Zhou X, Zhang W, Zhang S, Xi D. Detection of Tobacco Bacterial Wilt Caused by Ralstonia solanacearum by Combining Polymerase Chain Reaction with an α-Hemolysin Nanopore. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:332. [PMID: 36678085 PMCID: PMC9863824 DOI: 10.3390/nano13020332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 01/10/2023] [Accepted: 01/11/2023] [Indexed: 06/17/2023]
Abstract
Tobacco bacterial wilt is a serious disease caused by the soil-borne bacterium Ralstonia solanacearum (R. solanacearum). Herein, a rapid and purification-free α-hemolysin (α-HL) nanopore-sensing strategy based on polymerase chain reaction (PCR) and lambda exonuclease digestion was established to detect R. solanacearum. A 198-nucleotide-long single-stranded DNA was obtained via asymmetric PCR or the lambda exonuclease-mediated digestion of the PCR product. The DNA fragment produced unique long-lived, current-blocking signals when it passed through the α-HL nanopore. This sensing approach can allow for the determination of R. solanacearum in tobacco samples and can be conveniently extended to other DNA monitoring because of the extremely wide range of PCR applications.
Collapse
Affiliation(s)
- Ying Wang
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, College of Life Science, Linyi University, Linyi 276005, China
| | - Yusen Li
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, College of Life Science, Linyi University, Linyi 276005, China
| | - Xin Zhou
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, College of Life Science, Linyi University, Linyi 276005, China
| | - Wenna Zhang
- Shandong (Linyi) Institute of Modern Agriculture, Zhejiang University, Linyi 276000, China
| | - Shusheng Zhang
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, College of Life Science, Linyi University, Linyi 276005, China
| | - Dongmei Xi
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, College of Life Science, Linyi University, Linyi 276005, China
| |
Collapse
|
26
|
Chai H, Ma Y, Yuan Z, Li Y, Liu G, Chen L, Tian Y, Tan W, Ma J, Zhang G. A ratiometric fluorescence sensor based on carbon dots and two-dimensional porphyrinic MOFs for on-site monitoring of sulfide. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
27
|
Xu ZH, Liu J, Li B, Wang JK, Zeng X, Chen ZJ, Hongsibsong S, Huang W, Lei HT, Sun YM, Xu ZL. The Simultaneous Determination of Chlorpyrifos-Ethyl and -Methyl with a New Format of Fluorescence-Based Immunochromatographic Assay. BIOSENSORS 2022; 12:1006. [PMID: 36421124 PMCID: PMC9688337 DOI: 10.3390/bios12111006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 11/07/2022] [Accepted: 11/08/2022] [Indexed: 06/16/2023]
Abstract
The improper and excessive use in agriculture of chlorpyrifos-methyl (CPSM) and chlorpyrifos-ethyl (CPSE) may affect the health of human beings. Herein, a fluorescence-based immunochromatographic assay (FICA) was developed for the simultaneous determination of CPSM and CPSE. A monoclonal antibody (mAb) with equal recognition of CPSM and CPSE was generated by the careful designing of haptens and screening of hybridoma cells. Instead of labeling fluorescence with mAb, the probe was labeled with goat-anti-mouse IgG (GAM-IgG) and pre-incubated with mAb in the sample. The complex could compete with CPS by coating antigen in the test line. The new format of FICA used goat-anti-rabbit IgG (GAR-IgG) conjugated with rabbit IgG labeled with fluorescence microspheres as an independent quality control line (C line). The novel strategy significantly reduced nonspecific reactions and increased assay sensitivity. Under the optimal conditions, the proposed FICA showed a linear range of 0.015-64 mg/L and limit of detection (LOD) of 0.015 mg/L for both CPSE and CPSM. The average recoveries of CPS from spiked food samples by FICA were 82.0-110.0%. The accuracy was similar to the gas chromatography-tandem mass spectrometry (GC-MS/MS) results. The developed FICA was an ideal on-site tool for rapid screening of CPS residues in foods.
Collapse
Affiliation(s)
- Zi-Hong Xu
- Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642, China
| | - Jia Liu
- Guangzhou Institute of Food Inspection, Guangzhou 510410, China
| | - Bin Li
- Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642, China
- Guangdong Dayuanlvzhou Food Safety Technology Co., Ltd., Guangzhou 510530, China
| | - Jun-Kai Wang
- Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642, China
| | - Xi Zeng
- Guangzhou Institute of Food Inspection, Guangzhou 510410, China
| | - Zi-Jian Chen
- Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642, China
| | - Surat Hongsibsong
- School of Health Sciences Research, Research Institute for Health Science, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Wei Huang
- Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642, China
| | - Hong-Tao Lei
- Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642, China
| | - Yuan-Ming Sun
- Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642, China
| | - Zhen-Lin Xu
- Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou 510642, China
| |
Collapse
|
28
|
Ghasemi F, Fahimi-Kashani N, Bigdeli A, Alshatteri AH, Abbasi-Moayed S, Al-Jaf SH, Merry MY, Omer KM, Hormozi-Nezhad MR. Paper-based optical nanosensors – A review. Anal Chim Acta 2022; 1238:340640. [DOI: 10.1016/j.aca.2022.340640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022]
|
29
|
Portable Plasmonic Paper-Based Biosensor for Simple and Rapid Indirect Detection of CEACAM5 Biomarker via Metal-Enhanced Fluorescence. Int J Mol Sci 2022; 23:ijms231911982. [PMID: 36233297 PMCID: PMC9569726 DOI: 10.3390/ijms231911982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 10/05/2022] [Accepted: 10/07/2022] [Indexed: 11/07/2022] Open
Abstract
Rapid, simple, and sensitive analysis of relevant proteins is crucial in many research areas, such as clinical diagnosis and biomarker detection. In particular, clinical data on cancer biomarkers show great promise in forming reliable predictions for early cancer diagnostics, although the current analytical systems are difficult to implement in regions of limited recourses. Paper-based biosensors, in particular, have recently received great interest because they meet the criteria for point-of-care (PoC) devices; the main drawbacks with these devices are the low sensitivity and efficiency in performing quantitative measurements. In this work, we design a low-cost paper-based nanosensor through plasmonic calligraphy by directly drawing individual plasmonic lines on filter paper using a ballpoint pen filled with gold nanorods (AuNR) as the colloidal ink. The plasmonic arrays were further successively coated with negatively and positively charged polyelectrolyte layers employed as dielectric spacers to promote the enhancement of the emission of carboxyl-functionalized quantum dots (QD)—previously conjugated with specific antibodies—for indirect detection of the carcinoembryonic antigen-related cell adhesion molecule 5 (CEACAM5). The efficiency, sensitivity, as well as the specificity of our portable nanosensor were validated by recording the luminescence of the QD@Ab complex when different concentrations of CEACAM5 were added dropwise onto the calligraphed plasmonic arrays.
Collapse
|
30
|
Sensitive and simultaneous detection of ractopamine and salbutamol using multiplex lateral flow immunoassay based on polyethyleneimine-mediated SiO2@QDs nanocomposites: Comparison and application. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
31
|
Current Trends and Challenges in Point-of-care Urinalysis of Biomarkers in Trace Amounts. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
32
|
Song T, Zhang L, Guo Z, Hong Q, Zheng K, Wu Y, Cao H, Liao M, Fang Q. Sensitive Immunochromatographic Assay (ICA) for the Determination of Thiamethoxam in Fruit, Vegetables, and Natural Water. ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2110257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Tianwei Song
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| | - Linwei Zhang
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
| | - Zhihui Guo
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| | - Qiwen Hong
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
| | - Kang Zheng
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
| | - Yancan Wu
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Hefei Inspection Center for Agricultural Products Quality, Anhui Province, Hefei, China
| | - Haiqun Cao
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| | - Min Liao
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| | - Qingkui Fang
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| |
Collapse
|
33
|
Zhang R, Liao T, Wang X, Zhai H, Yang D, Wang X, Wang H, Feng F. Second near-infrared fluorescent dye for lateral flow immunoassays rapid detection of influenza A/B virus. Anal Biochem 2022; 655:114847. [PMID: 35964731 DOI: 10.1016/j.ab.2022.114847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 07/29/2022] [Accepted: 08/02/2022] [Indexed: 11/19/2022]
Abstract
Sensitive and rapid diagnostic point of care testing (POCT) system is of great significance to prevent and control human virus infection. Here reported an immunochromatographic strip technology. The second near-infrared (NIR-II) fluorescent dye encapsulated into polystyrene (PS) nanoparticles, was integrated into a lateral flow assay platform to achieve excellent detection of influenza A/B. This surface-functionalized and mono-dispersed PS nanoparticles has been conjugated with influenza nucleoprotein monoclonal antibody as targets for influenza antigen-detection. This assay achieved the detection limit of 0.015 ng/mL for influenza A nucleoprotein and 4.3*10-5 HAU/mL (102.08 TCID50/mL) influenza A virus (influenza B: 0.037 ng/mL, 9.7*10-7 HAU/mL (100.43 TCID50/mL)). Compared with an Au-based lateral flow test strip, the strip's sensitivity is about 16-fold higher than it. Strip detection properties remain stable for 6 months under 4 °C to 30 °C storage. The assay's intra assay variation is 5.14% and the inter assay variation is 7.74%. Other potential endogenous and exogenous interfering substances (whole blood, nasal mucin, saliva, antipyretics, antihistamines and neuraminidase inhibitors) showed negative results, which verified the excellent specificity of this method. This assay was successfully applied to the POCT quantitative detection of influenza A/B virus, the sensitivity to influenza A and B viruses was 70% and 87.5% respectively, and the specificity was 100%. Therefore, these microspheres can be used as an effective material for rapid POCT detection in clinical specimens.
Collapse
Affiliation(s)
- Runxuan Zhang
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| | - Tao Liao
- WWHS Biotech, Inc, China, Shenzhen, 518000, China
| | - Xiao Wang
- Institute of Public Security, Northwest University of Political Science and Law, China, Xi'an, 710122, China
| | - Hong Zhai
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| | - Di Yang
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| | - Xin Wang
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| | - Haiyan Wang
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China.
| | - Feng Feng
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| |
Collapse
|
34
|
Bian L, Li Z, He A, Wu B, Yang H, Wu Y, Hu F, Lin G, Zhang D. Ultrabright nanoparticle-labeled lateral flow immunoassay for detection of anti-SARS-CoV-2 neutralizing antibodies in human serum. Biomaterials 2022; 288:121694. [PMID: 35977850 PMCID: PMC9360774 DOI: 10.1016/j.biomaterials.2022.121694] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 07/13/2022] [Accepted: 07/20/2022] [Indexed: 11/02/2022]
Abstract
The level of anti-SARS-CoV-2 neutralizing antibodies (NAb) is an indispensable reference for evaluating the acquired protective immunity against SARS-CoV-2. Here, we established an ultrabright nanoparticles-based lateral flow immunoassay (LFIA) for one-step rapid semi-quantitative detection of anti-SARS-CoV-2 NAb in vaccinee's serum. Once embedded in polystyrene (PS) nanoparticles, the aggregation-induced emission (AIE) luminogen, AIE490, exhibited ultrabright fluorescence due to the rigidity of PS and severe inhibition of intramolecular motions. The ultrabright AIE490-PS nanoparticle was used as a fluorescent marker of LFIA. Upon optimized conditions including incubation time, concentrations of coated proteins and conjugated nanoparticles, amounts of antigens modified on the surface of nanoparticles, dilution rate of serum samples, and so on, the ultrabright nanoparticles-based LFIA could accurately identify 70 negative samples and 63 positive samples from human serum (p < 0.0001). The intra- and inter-assay precisions of the established method are above 13% and 16%, respectively. The established LFIA has tremendous practical value of generalization as a rapid semi-quantitative detection method of anti-SARS-CoV-2 NAb. Meanwhile, the AIE490-PS nanoparticle is also promising to detect many other analytes by altering the protein on the surface.
Collapse
Affiliation(s)
- Lun Bian
- Guangdong Province Key Laboratory of Construction and Detection in Tissue Engineering, Biomaterials Research Center, School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Zhaoyue Li
- Key Laboratory of Antibody Engineering of Guangdong Higher Education Institutes, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China
| | - An He
- The First People's Hospital of Chenzhou City, Chenzhou, China
| | - Biru Wu
- Guangdong Province Key Laboratory of Construction and Detection in Tissue Engineering, Biomaterials Research Center, School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Hui Yang
- Guangdong Province Key Laboratory of Construction and Detection in Tissue Engineering, Biomaterials Research Center, School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Yingsong Wu
- Key Laboratory of Antibody Engineering of Guangdong Higher Education Institutes, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China.
| | - Fang Hu
- Guangdong Province Key Laboratory of Construction and Detection in Tissue Engineering, Biomaterials Research Center, School of Biomedical Engineering, Southern Medical University, Guangzhou, China.
| | - Guanfeng Lin
- Experimental Center of Teaching and Scientific Research, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China.
| | - Deqing Zhang
- Beijing National Laboratory for Molecular Sciences, CAS Key Laboratory of Organic Solids, Institute of Chemistry, Chinese Academy of Sciences, Beijing, China
| |
Collapse
|
35
|
Hofmann A, Saft B, Reich P, Grabmann M, Glaser G, Trubenbach M, Rolapp A, Reinhard M, Scholz F, Schafer E. Lock-In Pixel CMOS Image Sensor for Time-Resolved Fluorescence Readout of Lateral-Flow Assays. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:535-544. [PMID: 35862324 DOI: 10.1109/tbcas.2022.3192926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
We present a CMOS image sensor (CIS) based time-resolved fluorescence (TRF) measurement system for filter-less, highly sensitive readout of lateral-flow assay (LFA) test strips. The CIS contains a 256 × 128 lock-in pixel (LIP) sensor array. Each pixel has a size of 10 μm × 10 μm and includes a photodiode acting as signal transducer. The LIP CIS was designed in a standard 0.18 μ m CMOS technology specifically for TRF applications. The LIP architecture blocks interfering light when fluorophores are excited and accumulates the emitted fluorescence light to be measured over multiple cycles after excitation. This allows to detect even small amounts of fluorescence light over a wide analyte concentration range. The LIP CIS based TRF reader was characterized in terms of reproducible and uniform signal intensities with use of appropriate Europium(III) [Eu 3+] chelate particles as fluorescence standards. We measured different concentrations of Eu-based nanoparticles (NP) on test strips with the TRF reader. The sensor system shows 5.1 orders of magnitude of detection dynamic range (DDR) with a limit of detection (LoD) of [Formula: see text]. In addition, using human C-reactive protein (hCRP) as a model analyte, we compared the developed TRF reader with a commercial colorimetric LFA reader. For the quantification of CRP, the LIP CIS based TRF reader demonstrates a DDR of 3.6 orders of magnitude with an excellent LoD of [Formula: see text], which is 14 times better than the LoD of the commercial LFA reader.
Collapse
|
36
|
Comparison of lateral flow immunoassays based on oriented and nonoriented immobilization of antibodies for the detection of aflatoxin B1. Anal Chim Acta 2022; 1221:340135. [DOI: 10.1016/j.aca.2022.340135] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 06/25/2022] [Accepted: 06/27/2022] [Indexed: 12/20/2022]
|
37
|
Zhuang H, Xu C, Gao F, Li Y, Lei C, Yu C. Recent Advances in Silica-Nanomaterial-Assisted Lateral Flow Assay. Bioengineering (Basel) 2022; 9:bioengineering9070266. [PMID: 35877318 PMCID: PMC9311751 DOI: 10.3390/bioengineering9070266] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/18/2022] [Accepted: 06/19/2022] [Indexed: 12/20/2022] Open
Abstract
Lateral flow assays (LFAs) have attracted much attention as rapid and affordable point-of-care devices for medical diagnostics. The global SARS-CoV-2 pandemic has further highlighted the importance of LFAs. Many efforts have been made to enhance the sensitivity of LFAs. In recent years, silica nanomaterials have been used to either amplify the signal of label materials or provide stability, resulting in better detection performance. In this review, the recent progress of silica-nanomaterial-assisted LFAs is summarized. The impact of the structure of silica nanomaterials on LFA performance, the challenges and prospects in this research area are also discussed.
Collapse
Affiliation(s)
- Han Zhuang
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
| | - Chun Xu
- School of Dentistry, The University of Queensland, Brisbane, QLD 4006, Australia;
| | - Fang Gao
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
| | - Yiwei Li
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
| | - Chang Lei
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
- Correspondence: (C.L.); (C.Y.)
| | - Chengzhong Yu
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St Lucia, QLD 4072, Australia; (H.Z.); (F.G.); (Y.L.)
- Correspondence: (C.L.); (C.Y.)
| |
Collapse
|
38
|
Hui YY, Tang Y, Azuma T, Lin H, Liao F, Chen Q, Kuo J, Wang Y, Chang H. Design and implementation of a low‐cost portable reader for thermometric lateral flow immunoassay. J CHIN CHEM SOC-TAIP 2022. [DOI: 10.1002/jccs.202200124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Yuen Yung Hui
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Yi‐Xiu Tang
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Terumitsu Azuma
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Department of Physics National Taiwan University Taipei Taiwan
| | - Hsin‐Hung Lin
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Fang‐Zhen Liao
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
| | - Qing‐Ying Chen
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Department of Chemical Engineering National Taiwan University of Science and Technology Taipei Taiwan
| | - Jen‐Hwa Kuo
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Institute of Brain Sciences National Yang Ming Chiao Tung University Taipei Taiwan
| | - Yuh‐Lin Wang
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Department of Physics National Taiwan University Taipei Taiwan
| | - Huan‐Cheng Chang
- Institute of Atomic and Molecular Sciences Academia Sinica Taipei Taiwan
- Department of Chemical Engineering National Taiwan University of Science and Technology Taipei Taiwan
- Department of Chemistry National Taiwan Normal University Taipei Taiwan
| |
Collapse
|
39
|
Emergence of dyestuff chemistry-encoded signal tracers in immunochromatographic assays: Fundamentals and recent food applications. Trends Food Sci Technol 2022. [DOI: 10.1016/j.tifs.2022.05.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
40
|
Zherdev AV, Dzantiev BB. Detection Limits of Immunoanalytical Systems: Limiting Factors and Methods of Reduction. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822040141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
41
|
Azuma T, Hui YY, Chen OY, Wang YL, Chang HC. Thermometric lateral flow immunoassay with colored latex beads as reporters for COVID-19 testing. Sci Rep 2022; 12:3905. [PMID: 35273286 PMCID: PMC8913781 DOI: 10.1038/s41598-022-07963-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Accepted: 02/28/2022] [Indexed: 12/16/2022] Open
Abstract
Temperature sensing is a promising method of enhancing the detection sensitivity of lateral flow immunoassay (LFIA) for point-of-care testing. A temperature increase of more than 100 °C can be readily achieved by photoexcitation of reporters like gold nanoparticles (GNPs) or colored latex beads (CLBs) on LFIA strips with a laser power below 100 mW. Despite its promise, processes involved in the photothermal detection have not yet been well-characterized. Here, we provide a fundamental understanding of this thermometric assay using non-fluorescent CLBs as the reporters deposited on nitrocellulose membrane. From a measurement for the dependence of temperature rises on the number density of membrane-bound CLBs, we found a 1.3-fold (and 3.2-fold) enhancement of the light absorption by red (and black) latex beads at 520 nm. The enhancement was attributed to the multiple scattering of light in this highly porous medium, a mechanism that could make a significant impact on the sensitivity improvement of LFIA. The limit of detection was measured to be 1 × 105 particles/mm2. In line with previous studies using GNPs as the reporters, the CLB-based thermometric assay provides a 10× higher sensitivity than color visualization. We demonstrated a practical use of this thermometric immunoassay with rapid antigen tests for COVID-19.
Collapse
Affiliation(s)
- Terumitsu Azuma
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC.,Department of Physics, National Taiwan University, Taipei, 106, Taiwan, ROC
| | - Yuen Yung Hui
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC
| | - Oliver Y Chen
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC
| | - Yuh-Lin Wang
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC.,Department of Physics, National Taiwan University, Taipei, 106, Taiwan, ROC
| | - Huan-Cheng Chang
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei, 106, Taiwan, ROC. .,Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei, 106, Taiwan, ROC. .,Department of Chemistry, National Taiwan Normal University, Taipei, 106, Taiwan, ROC.
| |
Collapse
|
42
|
Jia J, Ao L, Luo Y, Liao T, Huang L, Zhuo D, Jiang C, Wang J, Hu J. Quantum dots assembly enhanced and dual-antigen sandwich structured lateral flow immunoassay of SARS-CoV-2 antibody with simultaneously high sensitivity and specificity. Biosens Bioelectron 2022; 198:113810. [PMID: 34840014 PMCID: PMC8595965 DOI: 10.1016/j.bios.2021.113810] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 10/27/2021] [Accepted: 11/13/2021] [Indexed: 12/13/2022]
Abstract
Exploring reliable and highly-sensitive SARS-CoV-2 antibody diagnosis by point-of-care (POC) manner, holds great public health significance for extensive COVID-19 screening and controlling. Unfortunately, the currently applied gold based lateral flow immunoassay (GLFIA) may expose both false-negative and false-positive interpretations owing to the sensitivity and specificity limitations, which may cause significant risk and waste of public resources for large population screening. To simultaneously overcome the drawbacks of GLFIA, a novel fluorescent LFIA based on signal amplification and dual-antigen sandwich structure was established with largely improved sensitivity and specificity. The compact three-dimensional incorporation of hydrophobic quantum dots within dendritic affinity templates and multilayer surface derivation guaranteed a high and robust fluorescence of single label, which lowered the false negative rate of GLFIA prominently. A dual-antigen sandwich structure using labeled/immobilized SARS-CoV-2 spike receptor binding domain antigen for capturing total human SARS-CoV-2 antibody was developed, instead of general indirect antibody capturing approach, to reduce the false positive rate of GLFIA. Over 300 cases of COVID-19 negative and 97 cases of COVID-19 positive samples, the current assay revealed a 100% sensitivity and 100% specificity confirmed by both polymerase chain reaction (PCR) and chemiluminescence immunoassay (CLIA), compared with the considerable misinterpretation cases by currently applied GLFIA. The quantitative results verified by receiver operating characteristic curve and other statistical analysis indicated a well-distinguished positive/negative sample groups. The proposed strategy is highly sensitive towards low concentrated SARS-CoV-2 antibody serums and highly specific towards serums from COVID-19 negative persons and patients infected by other viruses.
Collapse
Affiliation(s)
- Jianghua Jia
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China; Medicalsystem Biotechnology Co., Ltd, Ningbo, 315104, China
| | - Lijiao Ao
- Institute of Biomedical Engineering, The Second Clinical Medical College (Shenzhen People's Hospital) of Jinan University, Shenzhen, 518020, China
| | - Yongxin Luo
- Xinyu People's Hospital, Xinyu, 338000, China
| | - Tao Liao
- Shenzhen WWHS Biotech. Inc, Shenzhen, 518100, China
| | - Liang Huang
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China.
| | - Dinglv Zhuo
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Chenxing Jiang
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Jing Wang
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China.
| | - Jun Hu
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China.
| |
Collapse
|
43
|
Li D, Huang M, Shi Z, Huang L, Jin J, Jiang C, Yu W, Guo Z, Wang J. Ultrasensitive Competitive Lateral Flow Immunoassay with Visual Semiquantitative Inspection and Flexible Quantification Capabilities. Anal Chem 2022; 94:2996-3004. [PMID: 35107983 DOI: 10.1021/acs.analchem.1c05364] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Antibiotics abuse has caused various problems threatening human health and ecological environment. Monitoring antibiotics residual levels is of great significance, yet still challenging for quantitative point-of-need testing with high-sensitivity and visual capability. Here we developed a competitive lateral flow immunoassay (CLFIA) platform with flexible readout for enrofloxacin (ENR), a regularly added antibiotic. To overcome the limitation of low sensitivity of traditional colloidal gold-based CLFIA, the three-dimensionally assembled gold nanoparticles (AuNPs) within dendritic silica scaffold were fabricated as signal reporters. The assembly structure effectively retained the intrinsic absorption features of hydrophobic AuNPs and greatly enhanced the light extinction ability of a single label for signal amplification. The obtained CLFIA strips can not only achieve qualitative screening of ENR at a very low concentration by naked eye (cutoff value: 0.125 ng/mL), but also enable ultrasensitive quantification of ENR by an optical scanner (limit of detection: 0.00195 ng/mL) or a smartphone (limit of detection: 0.0078 ng/mL). Moreover, to elaborate the visual inspection degree of CLFIA against traditional yes/no interpretation, a novel multirange gradient CLFIA strip was prepared for visually semiquantitative identification of ENR with four concentration ranges. The novel CLFIA platform demonstrated sensitive, specific, and reliable determination of ENR with flexible signal readout and provides a potential and invigorating pathway to point-of-need immunoassay of antibiotics.
Collapse
Affiliation(s)
- Daquan Li
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Mei Huang
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Ziyu Shi
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Liang Huang
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Jiening Jin
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Chenxing Jiang
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Wenbo Yu
- College of Veterinary Medicine, China Agricultural University. Beijing 100193 (PR China)
| | - Zhiyong Guo
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211(PR China)
| | - Jing Wang
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| |
Collapse
|
44
|
Chen H, Wang Y, Wei H, Rong Z, Wang S. A rapid water bath PCR combined with lateral flow assay for the simultaneous detection of SARS-CoV-2 and influenza B virus. RSC Adv 2022; 12:3437-3444. [PMID: 35425347 PMCID: PMC8979286 DOI: 10.1039/d1ra07756b] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 01/15/2022] [Indexed: 12/12/2022] Open
Abstract
The outbreak of the coronavirus disease 2019 caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in significant global health and economic threats to the human society. Thus, a rapid and accurate detection method for early testing and diagnosis should be established. In this study, a rapid water bath polymerase chain reaction (PCR) combined with lateral flow assay was developed to detect SARS-CoV-2 and influenza B virus simultaneously. A homemade automated transfer device equipped with reaction tube shuttled rapidly between two water baths at 98 °C and 53 °C to realize rapid PCR. After amplification, two-ended labeled PCR products were detected using the lateral flow strip with two test lines and streptavidin-conjugated quantum dot nanobeads. The fluorescence value was read using a handheld instrument. The established assay could complete reverse-transcription PCR amplification and lateral flow detection in 45 minutes. The detection limits were 8.44 copies per μL and 14.23 copies per μL for SARS-CoV-2 and influenza B virus, respectively. The coefficients of variation of the test strip were 10.10% for the SARS-CoV-2 and 4.94% for the influenza B virus, demonstrating the excellent repeatability of the experiment. These results indicated that the rapid PCR combined with lateral flow assay could detect SARS-CoV-2 and influenza B virus simultaneously at a short assay time and low cost, thereby showing the remarkable potential for the rapid and multiplex detection of respiratory viruses in resource-limited settings. Rapid and highly sensitive multiplex detection of SARS-CoV-2 and influenza B virus using water bath PCR-combined fluorescent lateral flow assay.![]()
Collapse
Affiliation(s)
- Hong Chen
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| | - Yunxiang Wang
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| | - Hongjuan Wei
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| | - Zhen Rong
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| |
Collapse
|
45
|
Danthanarayana AN, Brgoch J, Willson RC. Photoluminescent Molecules and Materials as Diagnostic Reporters in Lateral Flow Assays. ACS APPLIED BIO MATERIALS 2022; 5:82-96. [PMID: 35014811 PMCID: PMC9798899 DOI: 10.1021/acsabm.1c01051] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The lateral flow assay (LFA) is a point-of-care diagnostic test commonly available in an over-the-counter format because of its simplicity, speed, low cost, and portability. The reporter particles in these assays are among their most significant components because they perform the diagnostic readout and dictate the test's sensitivity. Today, gold nanoparticles are frequently used as reporters, but recent work focusing on photoluminescent-based reporter technologies has pushed LFAs to better performance. These efforts have focused specifically on reporters made of organic fluorophores, quantum dots, lanthanide chelates, persistent luminescent phosphors, and upconversion phosphors. In most cases, photoluminescent reporters show enhanced sensitivity compared to conventional gold nanoparticle-based assays. Here, we examine the advantages and disadvantages of these different reporters and highlight their potential benefits in LFAs. Our assessment shows that photoluminescent-based LFAs can not only reach lower detection limits than LFAs with traditional reporters, but they also can be capable of quantitative and multiplex analyte detection. As a result, the photoluminescent reporters make LFAs well-suited for medical diagnostics, the food and agricultural industry, and environmental testing.
Collapse
Affiliation(s)
| | - Jakoah Brgoch
- Department of Chemistry, University of Houston, Houston, Texas 77204, United States
| | - Richard C Willson
- Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77204, United States
- Department of Biology and Biochemistry, University of Houston, Houston, Texas 77204, United States
| |
Collapse
|
46
|
Wang Z, Zhao J, Xu X, Guo L, Xu L, Sun M, Hu S, Kuang H, Xu C, Li A. An Overview for the Nanoparticles-Based Quantitative Lateral Flow Assay. SMALL METHODS 2022; 6:e2101143. [PMID: 35041285 DOI: 10.1002/smtd.202101143] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/27/2021] [Indexed: 06/14/2023]
Abstract
The development of the lateral flow assay (LFA) has received much attention in both academia and industry because of their broad applications to food safety, environmental monitoring, clinical diagnosis, and so forth. The user friendliness, low cost, and easy operation are the most attractive advantages of the LFA. In recent years, quantitative detection has become another focus of LFA development. Here, the most recent studies of quantitative LFAs are reviewed. First, the principles and corresponding formats of quantitative LFAs are introduced. In the biomaterial and nanomaterial sections, the detection, capture, and signal amplification biomolecules and the optical, fluorescent, luminescent, and magnetic labels used in LFAs are described. The invention of dedicated strip readers has drawn further interest in exploiting the better performance of LFAs. Therefore, next, the development of dedicated reader devices is described and the usefulness and specifications of these devices for LFAs are discussed. Finally, the applications of LFAs in the detection of metal ions, biotoxins, pathogenic microorganisms, veterinary drugs, and pesticides in the fields of food safety and environmental health and the detection of nucleic acids, biomarkers, and viruses in clinical analyses are summarized.
Collapse
Affiliation(s)
- Zhongxing Wang
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Jing Zhao
- Department of Radiology, Affiliated Hospital, Jiangnan University, No. 1000, Hefeng Road, Wuxi, Jiangsu, 214122, China
| | - Xinxin Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Lingling Guo
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Liguang Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Maozhong Sun
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Shudong Hu
- Department of Radiology, Affiliated Hospital, Jiangnan University, No. 1000, Hefeng Road, Wuxi, Jiangsu, 214122, China
| | - Hua Kuang
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Chuanlai Xu
- State Key Laboratory of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, No. 1800, Lihu Road, Wuxi, Jiangsu, 214122, P. R. China
| | - Aike Li
- Academy of National Food and Strategic Reserves Administration, No. 11, Baiwanzhuang Street, Beijing, 100037, P. R. China
| |
Collapse
|
47
|
Xu X, Guo L, Kuang H, Xu L, Xu C, Liu L. Preparation of a broad-specific monoclonal antibody and development of an immunochromatographic assay for monitoring of anthranilic diamides in vegetables and fruits. Analyst 2022; 147:5149-5160. [DOI: 10.1039/d2an01366e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A mAb-based lateral flow immunochromatographic strip for the detection of anthranilic diamides in vegetables and fruits was developed. The strip provided cut-off values of 2.5, 5, 10, and 10 ng g−1 for CHL, CYA, CYC, and TEA, respectively.
Collapse
Affiliation(s)
- Xinxin Xu
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
| | - Lingling Guo
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
| | - Hua Kuang
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
| | - Liguang Xu
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
| | - Chuanlai Xu
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
| | - Liqiang Liu
- International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu 214122, P. R. China
| |
Collapse
|
48
|
Li N, Xi X, Zhu J, Wu X, Zhang X, Wang S, Wen W. High sensitivity and rapid detection of hepatitis B virus DNA using lateral flow biosensors based on Au@Pt nanorods in the absence of hydrogen peroxide. Analyst 2022; 147:423-429. [DOI: 10.1039/d1an02084f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Au@Pt nanorods with enhanced oxidase-like activity were designed and used as signal probes to construct LFBs for the high sensitivity detection of hepatitis B virus DNA (HBV-DNA).
Collapse
Affiliation(s)
- Niu Li
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-Constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan 430062, PR China
| | - Xiaoxue Xi
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-Constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan 430062, PR China
| | - Junlun Zhu
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-Constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan 430062, PR China
| | - Xiaowei Wu
- Departemnt of Thoracic Surgery, Tongji Hospital, Tongji Medical Collage of Huazhong University of Science and Technology, Wuhan 430030, PR China
| | - Xiuhua Zhang
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-Constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan 430062, PR China
| | - Shengfu Wang
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-Constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan 430062, PR China
| | - Wei Wen
- Collaborative Innovation Center for Advanced Organic Chemical Materials Co-Constructed by the Province and Ministry, Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, College of Chemistry and Chemical Engineering, Hubei University, Wuhan 430062, PR China
| |
Collapse
|
49
|
Xu C, ye L, Xu XX, Song S, xu L, Kuang H. Rapid colloidal gold immunochromatographic assay for the detection of SARS-CoV-2 total antibodies after vaccination. J Mater Chem B 2022; 10:1786-1794. [DOI: 10.1039/d1tb02521j] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
An epidemic caused by the severe acute respiratory syndrome coronavirus (SARS-CoV-2) spread globally in just a few months. To help prevent the further spread of the virus, millions of people...
Collapse
|
50
|
Lorusso M, Adorisio E, Gagliardi G, Meneghini A, Lagravinese D, Lerario MA. Qualitative evaluation of the new rapid point-of-care antigen Afias Covid-19/Flu Ag Combo assay. MICROBIOLOGIA MEDICA 2021. [DOI: 10.4081/mm.2021.10315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background: An interim guidance document by the WHO (World Health Organization) suggests the use of rapid diagnostic tests based on antigen detection as an alternative to the real-time PCR test for the diagnosis of SARS-CoV2 infection, when the molecular RT-PCR test is not available, or the turnaround time is excessive, precluding its clinical and/or public health usefulness. Rapid antigenic tests are recommended when a minimum of 80% sensitivity and 97% specificity are ensured.
Methods: Here we employ a new assay for screening applications based on lateral-flow immunofluorescence assay, with microfluidic technology (Boditech AFIAS COVID-19/Flu Ag Combo) on a point-of-care analyzer AFIAS-6 (BoditechMed. Inc.) and compare it with a reference molecular method and an alternative screening immunochromatographic method (Boditech AFIAS COVID-19 Ag). Our study was carried out on stored UTM (at -20°C) samples of patients admitted to Di Venere Hospital of Bari that were already tested with molecular methods.
Results: The new AFIAS COVID-19 Flu/Ag Combo test reached a clinical sensitivity of 92% on positive samples with Ct< 30, and a clinical specificity of 97.9% on negative samples. Sensitivity is higher than the reference immunochromatographic test AFIAS COVID-19/Ag (92.0% vs 88.0%) while specificity remains unchanged (97.9% vs 98.0%). In addition the new AFIAS Combo test confirm the same negative predictive value (NPV, 95.9%) of the rapid reference test (AFIAS COVID 19-Ag) and an agreement with the molecular test of 95.9% (Cohen's k = 0.908).
Conclusions: Considering its qualitative improvement, rapidity and ease of use we suggests AFIAS Combo test as a valid alternative to the reference lateral flow test (AFIAS COVID-19 Ag) and an adequate screening test.
Keywords: SARS-CoV2; COVID-19; POCT; diagnosis; screening; immunoassay; rapid antigen test
Collapse
|