1
|
Lou C, Yang H, Hou Y, Huang H, Qiu J, Wang C, Sang Y, Liu H, Han L. Microfluidic Platforms for Real-Time In Situ Monitoring of Biomarkers for Cellular Processes. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307051. [PMID: 37844125 DOI: 10.1002/adma.202307051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/05/2023] [Indexed: 10/18/2023]
Abstract
Cellular processes are mechanisms carried out at the cellular level that are aimed at guaranteeing the stability of the organism they comprise. The investigation of cellular processes is key to understanding cell fate, understanding pathogenic mechanisms, and developing new therapeutic technologies. Microfluidic platforms are thought to be the most powerful tools among all methodologies for investigating cellular processes because they can integrate almost all types of the existing intracellular and extracellular biomarker-sensing methods and observation approaches for cell behavior, combined with precisely controlled cell culture, manipulation, stimulation, and analysis. Most importantly, microfluidic platforms can realize real-time in situ detection of secreted proteins, exosomes, and other biomarkers produced during cell physiological processes, thereby providing the possibility to draw the whole picture for a cellular process. Owing to their advantages of high throughput, low sample consumption, and precise cell control, microfluidic platforms with real-time in situ monitoring characteristics are widely being used in cell analysis, disease diagnosis, pharmaceutical research, and biological production. This review focuses on the basic concepts, recent progress, and application prospects of microfluidic platforms for real-time in situ monitoring of biomarkers in cellular processes.
Collapse
Affiliation(s)
- Chengming Lou
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Hongru Yang
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Ying Hou
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Haina Huang
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Jichuan Qiu
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Chunhua Wang
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Yuanhua Sang
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Hong Liu
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Lin Han
- Institute of Marine Science and Technology, Shandong University, Qingdao, Shandong, 266000, P. R. China
| |
Collapse
|
2
|
Takiguchi S, Kambara F, Tani M, Sugiura T, Kawano R. Simultaneous Recognition of Over- and Under-Expressed MicroRNAs Using Nanopore Decoding. Anal Chem 2023; 95:14675-14685. [PMID: 37675494 PMCID: PMC10797591 DOI: 10.1021/acs.analchem.3c02560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 08/28/2023] [Indexed: 09/08/2023]
Abstract
This paper describes a strategy for simultaneous recognition of over- and under-expressed microRNAs (miRNAs) using the method of signal classification-based nanopore decoding. MiRNA has attracted attention as a promising biomarker for cancer diagnosis owing to its cancer-type-specific expression patterns. While nanopore technology has emerged as a simple and label-free method to detect miRNAs and their expression patterns, recognizing patterns involving simultaneous over/under-expression is still challenging due to the inherent working principles. Here, inspired by the sequence design for DNA computation with nanopore decoding, we designed diagnostic DNA probes targeting two individual over/under-expressed miRNAs in the serum of oral squamous cell carcinoma. Through nanopore measurements, our designed probes exhibited characteristic current signals depending on the hybridized miRNA species, which were plotted on the scatter plot of duration versus current blocking ratio. The classified signals reflected the relative abundance of target miRNAs, thereby enabling successful pattern recognition of over/under-expressed miRNAs, even when using clinical samples. We believe that our method paves the way for miRNA-targeting simple diagnosis as a liquid biopsy.
Collapse
Affiliation(s)
- Sotaro Takiguchi
- Department
of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - Fumika Kambara
- Department
of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| | - Mika Tani
- Department
of Maxillofacial Diagnostic and Surgical Science, Field of Oral and
Maxillofacial Rehabilitation, Graduate School of Medical and Dental
Science, Kagoshima University, Kagoshima 890-8544, Japan
| | - Tsuyoshi Sugiura
- Department
of Maxillofacial Diagnostic and Surgical Science, Field of Oral and
Maxillofacial Rehabilitation, Graduate School of Medical and Dental
Science, Kagoshima University, Kagoshima 890-8544, Japan
- Division
of Oral and Maxillofacial Oncology and Surgical Sciences, Graduate
School of Dentistry, Tohoku University, Miyagi 980-8577, Japan
| | - Ryuji Kawano
- Department
of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, Tokyo 184-8588, Japan
| |
Collapse
|
3
|
Ji D, Zhao J, Liu Y, Wei D. Electrical Nanobiosensors for Nucleic Acid Based Diagnostics. J Phys Chem Lett 2023; 14:4084-4095. [PMID: 37125726 DOI: 10.1021/acs.jpclett.3c00495] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Recent advances in nanotechnologies have promoted the iterative updating of nucleic acid sensors. Among various sensing technologies, the electrical nanobiosensor is regarded as one of the most promising prospects to achieve rapid, precise, and point-of-care nucleic acid based diagnostics. In this Perspective, we introduce recent progresses in electrical nanobiosensors for nucleic acid detection. First, the strategies for improving detection performance are summarized, including chemical amplification and electrical amplification. Then, the detection mechanism of electrical nanobiosensors, such as electrochemical biosensors, field-effect transistors, and photoelectric enhanced biosensors, is illustrated. At the same time, their applications in cancer screening, pathogen detection, gene sequencing, and genetic disease diagnosis are introduced. Finally, challenges and future prospects in clinical application are discussed.
Collapse
Affiliation(s)
- Daizong Ji
- State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai 200433, China
- Department of Macromolecular Science, Fudan University, Shanghai 200433, China
- Laboratory of Molecular Materials and Devices, Fudan University, Shanghai 200433, China
| | - Junhong Zhao
- State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai 200433, China
- Department of Macromolecular Science, Fudan University, Shanghai 200433, China
- Laboratory of Molecular Materials and Devices, Fudan University, Shanghai 200433, China
| | - Yunqi Liu
- Laboratory of Molecular Materials and Devices, Fudan University, Shanghai 200433, China
- Institute of Chemistry, Chinese Academy of Science, Beijing 100190, China
| | - Dacheng Wei
- State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai 200433, China
- Department of Macromolecular Science, Fudan University, Shanghai 200433, China
- Laboratory of Molecular Materials and Devices, Fudan University, Shanghai 200433, China
| |
Collapse
|
4
|
Basak M, Mitra S, Gogoi M, Sinha S, Nemade HB, Bandyopadhyay D. Point-of-Care Biosensing of Urinary Tract Infections Employing Optoplasmonic Surfaces Embedded with Metal Nanotwins. ACS APPLIED BIO MATERIALS 2022; 5:5321-5332. [PMID: 36222059 DOI: 10.1021/acsabm.2c00720] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
We report the synthesis of gold nanotwins (Au NTs) on a solid and transparent glass substrate which in turn has been employed for the selective optoplasmonic detection of Escherichia coli (EC) bacteria in human urine for the point-of-care diagnosis of urinary tract infections (UTIs). As compared to the single nanoparticle systems (Au NPs), the Au NTs show an enriched localized surface plasmon resonance (LSPR) due to the enhancement of the electric field under electromagnetic irradiation, e.g., photon, which helps in improving the limits of detection. For this purpose, initially a simple glass surface has been coated with Au NPs, with the help of the linker 3-aminopropyl-triethoxysilane - APTES. The surface has been linked further with another Au NP with the help of the 1,10-alkane-dithiol linker with two thiol ends, which eventually leads to the development of the optoplasmonic surface with Au NTs and an enhanced LSPR response. Subsequently, the EC specific aptamer has been chemically immobilized on the surface of Au NTs with the blocking of free sites via bovine serum albumin (BSA). Remarkably, Raman spectroscopy unfolds a 7-fold increase in the peak intensities with the Au NTs on the glass surface as compared to the surface coated with isolated Au NPs. The enhancement in the LSPR response of glass substrates coated with Au NTs and the EC specific aptamer has been further utilized for the selective and sensitive detection of UTIs. The results have been verified with the help of UV-visible spectroscopy to establish the utility of the proposed sensing methodology. An extensive interference study with other bacterial species unveils the selectivity and specificity of the proposed optoplasmonic sensors toward EC with a detection range of 5 × 103 to 107 CFU/mL. Intuitively, the method is more versatile in a sense that the sensor can be made specific to any other pathogens by simply changing the design of the aptamer. Finally, a low-cost, portable, and point-of-care optoplasmonic transduction setup is designed with a laser light illumination source, a sample holder, and a sensitive photodetector for the detection of UTIs in human urine.
Collapse
Affiliation(s)
- Mitali Basak
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati, Assam781039, India
| | - Shirsendu Mitra
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam781039, India
| | - Mousumi Gogoi
- Altanostics Laboratories Private Limited, Indian Institute of Technology Guwahati, Guwahati, Assam781039, India
| | - Swapnil Sinha
- Altanostics Laboratories Private Limited, Indian Institute of Technology Guwahati, Guwahati, Assam781039, India
| | - Harshal B Nemade
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati, Assam781039, India
| | - Dipankar Bandyopadhyay
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati, Assam781039, India.,Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam781039, India.,School of Health Sciences and Technology, Indian Institute of Technology Guwahati, Guwahati, Assam781039, India
| |
Collapse
|
5
|
Xiang Y, Hu C, Wu G, Xu S, Li Y. Nanomaterial-based microfluidic systems for cancer biomarker detection: Recent applications and future perspectives. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
6
|
Current Trends and Challenges in Point-of-care Urinalysis of Biomarkers in Trace Amounts. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
7
|
Advances in multiplex electrical and optical detection of biomarkers using microfluidic devices. Anal Bioanal Chem 2022; 414:167-180. [PMID: 34345949 PMCID: PMC8331214 DOI: 10.1007/s00216-021-03553-8] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 07/13/2021] [Accepted: 07/14/2021] [Indexed: 02/07/2023]
Abstract
Microfluidic devices can provide a versatile, cost-effective platform for disease diagnostics and risk assessment by quantifying biomarkers. In particular, simultaneous testing of several biomarkers can be powerful. Here, we critically review work from the previous 4 years up to February 2021 on developing microfluidic devices for multiplexed detection of biomarkers from samples. We focus on two principal approaches: electrical and optical detection methods that can distinguish and quantify biomarkers. Both electrical and spectroscopic multiplexed detection strategies are being employed to reach limits of detection below clinical sample levels. Some of the most promising strategies for point-of-care assays involve inexpensive materials such as paper-based microfluidic devices, or portable and accessible detectors such as smartphones. This review does not comprehensively cover all multiplexed microfluidic biomarker studies, but rather provides a critical evaluation of key work and suggests promising prospects for future advancement in this field. Electrical and optical multiplexing are powerful approaches for microfluidic biomarker analysis.
Collapse
|
8
|
Yeung WK, Lo SC, Wang SH, Wei PK, Cheng JY. Dispersion-enhancing surface treatment of AuNPs for a reduced probe loading and detection limit using t-SPR detection. Analyst 2021; 146:5584-5591. [PMID: 34369484 DOI: 10.1039/d1an00973g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
COVID-19 has shown that a highly specific and rapid diagnostic system is a necessity. A spectral imaging-based surface plasmon resonance (SPRi) platform with an integrated microfluidic biosensor to detect oligonucleotide sequences has been proposed to be a promising alternative for infectious diseases due to its safe and straightforward use. Approaches to reduce the DNA probe loading onto gold nanoparticles with various types of polyethylene glycol (PEG) were explored. Here, we demonstrated the stability of functionalised gold nanoparticles with unmodified PEG whilst lowering the probe loading density. The system was evaluated by performing the detection of a mimicking COVID-19 target sequence, single point-mutation sequence and fully mismatch sequence. Highly specific binding of the mimicking COVID-19 target sequence was observed and analysed by the spectral imaging SPR approach. Our work has demonstrated the potential of a controlled probe density using unmodified PEG as an especially promising functionalisation strategy in SPR spectral imaging assays.
Collapse
Affiliation(s)
- Wing Kiu Yeung
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan.
| | - Shu-Cheng Lo
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan. and Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan
| | - Sheng-Hann Wang
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan.
| | - Pei-Kuen Wei
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan.
| | - Ji-Yen Cheng
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan. and Institute of Biophotonics, National Yang Ming Chiao Tung University, Taipei, Taiwan and Department of Mechanical and Mechatronic Engineering, National Taiwan Ocean University, Taiwan and College of Engineering, Chang Gung University, Taoyuan, Taiwan
| |
Collapse
|
9
|
Olejnik B, Kozioł A, Brzozowska E, Ferens-Sieczkowska M. Application of selected biosensor techniques in clinical diagnostics. Expert Rev Mol Diagn 2021; 21:925-937. [PMID: 34289786 DOI: 10.1080/14737159.2021.1957833] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Examination of disease biomarkers mostly performed on crude materials, such as serum, meets some obstacles, resulting from sample complexity and the wide range of concentrations and sizes of the components. Techniques currently used in clinical diagnostics are usually time-consuming and expensive. The more sensitive and portable devices are needed for early diagnostics. Chemical sensors are devices that convert chemical information into parameters suitable for fast and precise processing and measurement. AREA COVERED We review the use of biosensors and their possible application in early diagnostics of some diseases like cancer or viral infections. We focus on different types of biorecognition and some technical modifications, lowering the limit of detection potentially attractive to medical practitioners. EXPERT OPINION Among the new diagnostic strategies, the use of biosensors is of increasing interest. In these techniques, the capture ligand interacts with the analyte of interest. Measuring interactions between partners in real time by surface plasmon resonance yields valuable information about kinetics and affinity in a short time and without labels. Importantly, the tendency in such techniques is to make biosensor devices smaller and the test results apparent with the naked eye, so they can be used in point-of-care medicine.
Collapse
Affiliation(s)
- Beata Olejnik
- Department of Chemistry and Immunochemistry, Medical University of Wroclaw, Wrocław, Poland
| | - Agata Kozioł
- Department of Chemistry and Immunochemistry, Medical University of Wroclaw, Wrocław, Poland
| | - Ewa Brzozowska
- Ludwik Hirszfeld Institute of Immunology and Experimental Therapy, Laboratory of Medical Microbiology, Wrocław, Poland
| | | |
Collapse
|
10
|
Liang Y, Lehrich BM, Zheng S, Lu M. Emerging methods in biomarker identification for extracellular vesicle-based liquid biopsy. J Extracell Vesicles 2021; 10:e12090. [PMID: 34012517 PMCID: PMC8114032 DOI: 10.1002/jev2.12090] [Citation(s) in RCA: 77] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 03/17/2021] [Accepted: 04/13/2021] [Indexed: 12/13/2022] Open
Abstract
Extracellular vesicles (EVs) are released by many cell types and distributed within various biofluids. EVs have a lipid membrane-confined structure that allows for carrying unique molecular information originating from their parent cells. The species and quantity of EV cargo molecules, including nucleic acids, proteins, lipids, and metabolites, may vary largely owing to their parent cell types and the pathophysiologic status. Such heterogeneity in EV populations provides immense challenges to researchers, yet allows for the possibility to prognosticate the pathogenesis of a particular tissue from unique molecular signatures of dispersing EVs within biofluids. However, the inherent nature of EV's small size requires advanced methods for EV purification and evaluation from the complex biofluid. Recently, the interdisciplinary significance of EV research has attracted growing interests, and the EV analytical platforms for their diagnostic prospect have markedly progressed. This review summarizes the recent advances in these EV detection techniques and methods with the intention of translating an EV-based liquid biopsy into clinical practice. This article aims to present an overview of current EV assessment techniques, with a focus on their progress and limitations, as well as an outlook on the clinical translation of an EV-based liquid biopsy that may augment current paradigms for the diagnosis, prognosis, and monitoring the response to therapy in a variety of disease settings.
Collapse
Affiliation(s)
- Yaxuan Liang
- Center for Biological Science and Technology, Advanced Institute of Natural SciencesBeijing Normal University at ZhuhaiZhuhaiChina
| | - Brandon M. Lehrich
- Medical Scientist Training ProgramUniversity of Pittsburgh School of Medicine and Carnegie Mellon UniversityPittsburghPennsylvaniaUSA
| | - Siyang Zheng
- Department Biomedical EngineeringCarnegie Mellon UniversityPittsburghPennsylvaniaUSA
- Department of Electrical and Computer EngineeringCarnegie Mellon UniversityPittsburghPennsylvaniaUSA
| | - Mengrou Lu
- Department Biomedical EngineeringCarnegie Mellon UniversityPittsburghPennsylvaniaUSA
| |
Collapse
|
11
|
Kim S, Park S, Cho YS, Kim Y, Tae JH, No TI, Shim JS, Jeong Y, Kang SH, Lee KH. Electrical Cartridge Sensor Enables Reliable and Direct Identification of MicroRNAs in Urine of Patients. ACS Sens 2021; 6:833-841. [PMID: 33284011 DOI: 10.1021/acssensors.0c01870] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Urinary miRNAs are biomarkers that demonstrate considerable promise for the noninvasive diagnosis and prognosis of diseases. However, because of background noise resulting from complex physiological features of urine, instability of miRNAs, and their low concentration, accurate monitoring of miRNAs in urine is challenging. To address these limitations, we developed a urine-based disposable and switchable electrical sensor that enables reliable and direct identification of miRNAs in patient urine. The proposed sensing platform combining disposable sensor chips composed of a reduced graphene oxide nanosheet and peptide nucleic acid facilitates the label-free detection of urinary miRNAs with high specificity and sensitivity. Using real-time detection of miRNAs in patient urine without pretreatment or signal amplification, this sensor allows rapid, direct detection of target miRNAs in a broad dynamic range with a detection limit down to 10 fM in human urine specimens within 20 min and enables simultaneous quantification of multiple miRNAs. As confirmed using a blind comparison with the results of pathological examination of patients with prostate cancer, the sensor offers the potential to improve the accuracy of early diagnosis before a biopsy is taken. This study holds the usefulness of the practical sensor for the clinical diagnosis of urological diseases.
Collapse
Affiliation(s)
- Seongchan Kim
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Sungwook Park
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Young Soo Cho
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Younghoon Kim
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Jong Hyun Tae
- Department of Urology, Korea University, School of Medicine, Seoul 02841, Republic of Korea
| | - Tae Il No
- Department of Urology, Korea University, School of Medicine, Seoul 02841, Republic of Korea
| | - Ji Sung Shim
- Department of Urology, Korea University, School of Medicine, Seoul 02841, Republic of Korea
| | - Youngdo Jeong
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
- Department of HY-KIST Bio-convergence, Hanyang University, Seoul 04763, Republic of Korea
| | - Seok Ho Kang
- Department of Urology, Korea University, School of Medicine, Seoul 02841, Republic of Korea
| | - Kwan Hyi Lee
- Center for Biomaterials, Biomedical Research Institute, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
- KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul 02841, Republic of Korea
| |
Collapse
|
12
|
Jet T, Gines G, Rondelez Y, Taly V. Advances in multiplexed techniques for the detection and quantification of microRNAs. Chem Soc Rev 2021; 50:4141-4161. [PMID: 33538706 DOI: 10.1039/d0cs00609b] [Citation(s) in RCA: 127] [Impact Index Per Article: 42.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
MicroRNA detection is currently a crucial analytical chemistry challenge: almost 2000 papers were referenced in PubMed in 2018 and 2019 for the keywords "miRNA detection method". MicroRNAs are potential biomarkers for multiple diseases including cancers, neurodegenerative and cardiovascular diseases. Since miRNAs are stably released in bodily fluids, they are of prime interest for the development of non-invasive diagnosis methods, such as liquid biopsies. Their detection is however challenging, as high levels of sensitivity, specificity and robustness are required. The analysis also needs to be quantitative, since the aim is to detect miRNA concentration changes. Moreover, a high multiplexing capability is also of crucial importance, since the clinical potential of miRNAs probably lays in our ability to perform parallel mapping of multiple miRNA concentrations and recognize typical disease signature from this profile. A plethora of biochemical innovative detection methods have been reported recently and some of them provide new solutions to the problem of sensitive multiplex detection. In this review, we propose to analyze in particular the new developments in multiplexed approaches to miRNA detection. The main aspects of these methods (including sensitivity and specificity) will be analyzed, with a particular focus on the demonstrated multiplexing capability and potential of each of these methods.
Collapse
Affiliation(s)
- Thomas Jet
- Centre de Recherche des Cordeliers, INSERM, Sorbonne Université, Université de Paris, CNRS SNC5096, Equipe Labellisée Ligue Nationale Contre le Cancer, F-75006 Paris, France.
| | | | | | | |
Collapse
|
13
|
Lu H, Hailin T, Yi X, Wang J. Three-Dimensional DNA Nanomachine Combined with Toehold-Mediated Strand Displacement Reaction for Sensitive Electrochemical Detection of MiRNA. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:10708-10714. [PMID: 32804511 DOI: 10.1021/acs.langmuir.0c01415] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
MicroRNA (miRNA) serves as an ideal biomarker for diagnosis, prognosis, and therapy of various human cancers. The rationally designed three-dimensional (3D) DNA nanomachine was constructed on the matrixes of magnetic beads, and the high density of gold nanoparticles (AuNPs) on each magnetic bead and further enlargement of the AuNPs lead to the anchoring of numerous DNA walkers and signal probes on the AuNPs. With the combination of toehold-mediated strand displacement reaction (SDR), amplified electrochemical detection of miRNA is performed. The existence of miRNA triggers the toehold-mediated SDR and the released DNA walker probe is hybridized with the ferrocene (Fc)-tagged signal probe. The cleavage of the duplex by the nicking endonuclease detaches the signal probe from the magnetic nanocomposites. The oxidation current of Fc moieties was found to be inversely proportional to the concentrations of miRNA-182 between 1.0 fM and 2 pM. The assay is highly selective for discrimination of miRNAs with similar sequences. The feasibility of the method for sensitive detection of the expression levels of miRNA-182 from serum samples of glioma patients at different stages was demonstrated. The sensing protocol holds great promise for early diagnosis and prognosis of the cancer cases with abnormal miRNA expression.
Collapse
Affiliation(s)
- Hanwen Lu
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan P. R. China 410083
| | - Tang Hailin
- SunYat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong P. R. China 510060
| | - Xinyao Yi
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan P. R. China 410083
| | - Jianxiu Wang
- Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan P. R. China 410083
| |
Collapse
|
14
|
Nurrohman DT, Wang YH, Chiu NF. Exploring Graphene and MoS 2 Chips Based Surface Plasmon Resonance Biosensors for Diagnostic Applications. Front Chem 2020; 8:728. [PMID: 33005604 PMCID: PMC7479841 DOI: 10.3389/fchem.2020.00728] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 07/14/2020] [Indexed: 01/16/2023] Open
Abstract
Until now, two-dimensional (2D) nanomaterials have been widely studied and applied in the biosensor field. Some of the advantages offered by these 2D materials include large specific surface area, high conductivity, and easy surface modification. This review discusses the use of 2D material in surface plasmon resonance (SPR) biosensor for diagnostic applications. Two-dimensional material reviewed includes graphene and molybdenum disulfide (MoS2). The discussion begins with a brief introduction to the general principles of the SPR biosensor. The discussion continues by explaining the properties and characteristics of each material and its effect on the performance of the SPR biosensor, in particular its sensitivity. This review concludes with some recent applications of graphene- and MoS2-based SPR biosensor in diagnostic applications.
Collapse
Affiliation(s)
- Devi Taufiq Nurrohman
- Laboratory of Nano-photonics and Biosensors, Institute of Electro-Optical Engineering, National Taiwan Normal University, Taipei, Taiwan
- Department of Electronics Engineering, State Polytechnic of Cilacap, Cilacap, Indonesia
| | - Ying-Hao Wang
- Laboratory of Nano-photonics and Biosensors, Institute of Electro-Optical Engineering, National Taiwan Normal University, Taipei, Taiwan
| | - Nan-Fu Chiu
- Laboratory of Nano-photonics and Biosensors, Institute of Electro-Optical Engineering, National Taiwan Normal University, Taipei, Taiwan
- Department of Life Science, National Taiwan Normal University, Taipei, Taiwan
| |
Collapse
|
15
|
Mauriz E. Low-Fouling Substrates for Plasmonic Sensing of Circulating Biomarkers in Biological Fluids. BIOSENSORS-BASEL 2020; 10:bios10060063. [PMID: 32531908 PMCID: PMC7345924 DOI: 10.3390/bios10060063] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 06/04/2020] [Accepted: 06/08/2020] [Indexed: 12/20/2022]
Abstract
The monitoring of biomarkers in body fluids provides valuable prognostic information regarding disease onset and progression. Most biosensing approaches use noninvasive screening tools and are conducted in order to improve early clinical diagnosis. However, biofouling of the sensing surface may disturb the quantification of circulating biomarkers in complex biological fluids. Thus, there is a great need for antifouling interfaces to be designed in order to reduce nonspecific adsorption and prevent inactivation of biological receptors and loss of sensitivity. To address these limitations and enable their application in clinical practice, a variety of plasmonic platforms have been recently developed for biomarker analysis in easily accessible biological fluids. This review presents an overview of the latest advances in the design of antifouling strategies for the detection of clinically relevant biomarkers on the basis of the characteristics of biological samples. The impact of nanoplasmonic biosensors as point-of-care devices has been examined for a wide range of biomarkers associated with cancer, inflammatory, infectious and neurodegenerative diseases. Clinical applications in readily obtainable biofluids such as blood, saliva, urine, tears and cerebrospinal and synovial fluids, covering almost the whole range of plasmonic applications, from surface plasmon resonance (SPR) to surface-enhanced Raman scattering (SERS), are also discussed.
Collapse
Affiliation(s)
- Elba Mauriz
- Department of Nursing and Physiotherapy, Universidad de León, Campus de Vegazana, s/n, 24071 León, Spain;
- Institute of Food Science and Technology (ICTAL), La Serna 58, 24007 León, Spain
| |
Collapse
|
16
|
Park HJ, Lee SS. QCM sensing of miR-21 by formation of microRNA-DNA hybrid duplexes and intercalation on surface-functionalized pyrene. Analyst 2020; 144:6936-6943. [PMID: 31617512 DOI: 10.1039/c9an01645g] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
MicroRNAs (miRNAs) are small non-coding RNA molecules that serve as important biomarkers for a variety of diseases such as cancer and vascular disease. However, sensitive and accurate detection of miR-21 is very challenging in that up-regulation of miR-21 is highly associated with several types of malignant tumors. Here, quartz crystal microbalance (QCM) biosensors were developed for sensitive and specific detection of miR-21 through formation of miR-21-DNA hybrid duplexes and non-specific intercalation of surface-modified pyrene molecules. High selectivity for miR-21 over other miRNAs came from the specific hybridization between miR-21 and gold nanoparticle (AuNP)-conjugated complementary oligonucleotides of miR-21. High sensitivity was obtained through formation of intercalated complexes on the surface with subsequent gold staining signal amplification. Under optimum condition using this strategic approach, our novel QCM biosensors could detect miR-21 concentration as low as 3.6 pM in the entire linear range from 2.5 pM to 2.5 μM with a correlation coefficient of 0.989. In addition, these sensors did not work at all for other miRNAs based on their high selectivity. miR-21 in human brain total RNA and total RNA extracted from A549 cell line could also be successfully detected. Therefore, miRNA detection technology using QCM biosensors and their detection mechanisms have potential as alternatives in biological studies and clinical diagnosis.
Collapse
Affiliation(s)
- Hyeoun Ji Park
- Department of Pharmaceutical Engineering, Soonchunhyang University, 22 Soonchunhyang-ro, Shinchang-myeon, Asan-si, Chungcheongnam-do 31538, Republic of Korea.
| | | |
Collapse
|
17
|
Chuang CS, Wu CY, Juan PH, Hou NC, Fan YJ, Wei PK, Sheen HJ. LMP1 gene detection using a capped gold nanowire array surface plasmon resonance sensor in a microfluidic chip. Analyst 2020; 145:52-60. [DOI: 10.1039/c9an01419e] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
A new detection device by using SPR nanowire array chip and a microfluidics system was developed. A simple, low-cost and reproducible SPR nanowire chip with a visible light source displayed real-time detection capability.
Collapse
Affiliation(s)
- Chih-Shen Chuang
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
- School of Biomedical Engineering
| | - Chieh-Ying Wu
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
| | - Po-Han Juan
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
| | - Nai-Cheng Hou
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
| | - Yu-Jui Fan
- School of Biomedical Engineering
- Taipei Medical University
- Taipei 11031
- Taiwan
- International PhD Program for Biomedical Engineering
| | - Pei-Kuen Wei
- Research Center for Applied Sciences
- Academia Sinica
- Taipei 11529
- Taiwan
| | - Horn-Jiunn Sheen
- Institute of Applied Mechanics
- National Taiwan University
- Taipei 10617
- Taiwan
| |
Collapse
|
18
|
Abstract
MicroRNAs (miRNAs) are endogenous noncoding RNAs, which regulate gene expression on the post-transcriptional level. Since miRNAs are involved in the regulation of apoptosis, cellular proliferation, differentiation, and other important cellular processes, their deregulation is important for the development of a wide range of diseases including cancer. Apart from tissue, specific disease-related miRNA signatures can be found in body fluids as well. Especially for urologic diseases or injuries, urine miRNAs represent a promising group of biomarkers. Despite a large number of studies describing the importance of urinary miRNAs, there is a lack of recommendations for urine management and subsequent miRNA analysis. Thus, in this chapter, we aim to describe the origin and functions of urinary miRNAs and discuss the technical aspects of their detection including the pre-analytical phase principles and new directions in quantification, which could forward urine miRNA into clinical practice.
Collapse
Affiliation(s)
- Jaroslav Juracek
- Central European Institute of Technology, Masaryk University, Brno, Czech Republic
| | - Ondrej Slaby
- Central European Institute of Technology, Masaryk University, Brno, Czech Republic.
| |
Collapse
|
19
|
Qu JH, Dillen A, Saeys W, Lammertyn J, Spasic D. Advancements in SPR biosensing technology: An overview of recent trends in smart layers design, multiplexing concepts, continuous monitoring and in vivo sensing. Anal Chim Acta 2019; 1104:10-27. [PMID: 32106939 DOI: 10.1016/j.aca.2019.12.067] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 12/04/2019] [Accepted: 12/24/2019] [Indexed: 12/22/2022]
Abstract
Inspired by the rapid progress and existing limitations in surface plasmon resonance (SPR) biosensing technology, we have summarized the recent trends in the fields of both chip-SPR and fiber optic (FO)-SPR biosensors during the past five years, primarily regarding smart layers design, multiplexing, continuous monitoring and in vivo sensing. Versatile surface chemistries, biomaterials and nanomaterials have been utilized thus far to generate smart layers on SPR platforms and as such achieve oriented immobilization of bioreceptors, improved fouling resistance and sensitivity enhancement, collectively aiming to improve the biosensing performance. Furthermore, often driven by the desires for time- and cost-effective quantification of multiple targets in a single measurement, efforts have been made to implement multiplex bioassays on SPR platforms. While this aspect largely remains difficult to attain, numerous alternative strategies arose for obtaining parallel analysis of multiple analytes in one single device. Additionally, one of the upcoming challenges in this field will be to succeed in using SPR platforms for continuous measurements and in vivo sensing, and as such match up other biosensing platforms where these goals have been already conquered. Overall, this review will give insight into multiple possibilities that have become available over the years for boosting the performance of SPR biosensors. However, because combining them all into one optimal sensor is practically not feasible, the final application needs to be considered while designing an SPR biosensor, as this will determine the requirements of the bioassay and will thus help in selecting the essential elements from the recent progress made in SPR sensing.
Collapse
Affiliation(s)
- Jia-Huan Qu
- KU Leuven, Department of Biosystems - Biosensors Group, Willem de Croylaan 42, Box 2428, 3001, Leuven, Belgium
| | - Annelies Dillen
- KU Leuven, Department of Biosystems - Biosensors Group, Willem de Croylaan 42, Box 2428, 3001, Leuven, Belgium
| | - Wouter Saeys
- KU Leuven, Department of Biosystems, MeBioS - Biophotonics, Kasteelpark Arenberg 30, Box 2456, 3001, Leuven, Belgium
| | - Jeroen Lammertyn
- KU Leuven, Department of Biosystems - Biosensors Group, Willem de Croylaan 42, Box 2428, 3001, Leuven, Belgium.
| | - Dragana Spasic
- KU Leuven, Department of Biosystems - Biosensors Group, Willem de Croylaan 42, Box 2428, 3001, Leuven, Belgium
| |
Collapse
|
20
|
Pan MY, Yang DK, Lai CY, Weng JH, Lee KL, Chen LC, Chou CF, Wei PK. Spectral contrast imaging method for mapping transmission surface plasmon images in metallic nanostructures. Biosens Bioelectron 2019; 142:111545. [PMID: 31376712 DOI: 10.1016/j.bios.2019.111545] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 06/30/2019] [Accepted: 07/26/2019] [Indexed: 11/28/2022]
Abstract
We propose a spectral contrast method to map the transmission images of surface plasmon resonance (SPR) in metallic nanostructures. Comparing the intensities between two neighboring wavelength bands near the SPR wavelength, the signal-to-noise ratio for biosensing applications obtained using the proposed method is found to be ten times higher than that obtained by conventional intensity analysis and 1.6 times better than that obtained by peak-wavelength fitting. The dynamic range and linearity of the refractive index are comparable to the peak-wavelength shift measurement. Based on the detection method, a spectral modulation system for the optical microscope is developed, combined with a gold-capped nanowire array, to measure the biointeractions in microfluidic devices. The experimental results show that the proposed method obtained multiple detections with a detection limit of 1.04 × 10-5 refractive index units. Two types of analysis methods for SPR images are used to study the protein-antibody interactions. The region-of-interest analysis supports multiplexing detections in a compact microfluidic sensor. The effective pixel analysis eliminates low-response pixels and enhances the signal-to-noise ratios for sensitive label-free detection.
Collapse
Affiliation(s)
- Ming-Yang Pan
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan
| | - Deng-Kai Yang
- Institute of Physics, Academia Sinica, Taipei, Taiwan
| | - Chih-Yu Lai
- Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, Taipei, Taiwan
| | - Jui-Hong Weng
- Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, Taipei, Taiwan
| | - Kuang-Li Lee
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan
| | - Lin-Chi Chen
- Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, Taipei, Taiwan
| | - Chia-Fu Chou
- Institute of Physics, Academia Sinica, Taipei, Taiwan
| | - Pei-Kuen Wei
- Research Center for Applied Sciences, Academia Sinica, Taipei, Taiwan; Institute of Biophotonics, National Yang-Ming University, Taipei, Taiwan; Department of Optoelectronics, National Taiwan Ocean University, Keelung, Taiwan.
| |
Collapse
|
21
|
Hou HS, Lee KL, Wang CH, Hsieh TH, Sun JJ, Wei PK, Cheng JY. Simultaneous assessment of cell morphology and adhesion using aluminum nanoslit-based plasmonic biosensing chips. Sci Rep 2019; 9:7204. [PMID: 31076598 PMCID: PMC6510726 DOI: 10.1038/s41598-019-43442-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Accepted: 04/24/2019] [Indexed: 11/13/2022] Open
Abstract
A variety of physiological and pathological processes rely on cell adhesion, which is most often tracked by changes in cellular morphology. We previously reported a novel gold nanoslit-based biosensor that is capable of real-time and label-free monitoring of cell morphological changes and cell viability. However, the preparation of gold biosensors is inefficient, complicated and costly. Recently, nanostructure-based aluminum (Al) sensors have been introduced for biosensing applications. The Al-based sensor has a longer decay length and is capable of analyzing large-sized mass such as cells. Here, we developed two types of double-layer Al nanoslit-based plasmonic biosensors, which were nanofabricated and used to evaluate the correlation between metastatic potency and adhesion of lung cancer and melanoma cell lines. Cell adhesion was determined by Fano resonance signals that were induced by binding of the cells to the nanoslit. The peak and dip of the Fano resonance spectrum respectively reflected long- and short-range cellular changes, allowing us to simultaneously detect and distinguish between focal adhesion and cell spreading. Also, the Al nanoslit-based biosensor chips were used to evaluate the inhibitory effects of drugs on cancer cell spreading. We are the first to report the use of double layer Al nanoslit-based biosensors for detection of cell behavior, and such devices may become powerful tools for anti-metastasis drug screening in the future.
Collapse
Affiliation(s)
- Hsien-San Hou
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan
| | - Kuang-Li Lee
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan
| | - Chen-Hung Wang
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan
| | - Tung-Han Hsieh
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan
| | - Juan-Jie Sun
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan
| | - Pei-Kuen Wei
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan.,Institute of Biophotonics, National Yang-Ming University, Taipei, 11221, Taiwan
| | - Ji-Yen Cheng
- Research Center for Applied Sciences, Academia Sinica, Taipei, 11529, Taiwan. .,Institute of Biophotonics, National Yang-Ming University, Taipei, 11221, Taiwan. .,Department of Mechanical and Mechatronic Engineering, National Taiwan Ocean University, Keelung, 20224, Taiwan. .,College of Engineering, Chang Gung University, Taoyuan, 33302, Taiwan.
| |
Collapse
|