1
|
Yang Q, Zhou W, Li H, Huang J, Song Z, Cheng L, Wu Y, Mu D. A continuous polymerase chain reaction 3D spiral microreactor capable of facile and on-demand fabrication. Anal Chim Acta 2024; 1310:342692. [PMID: 38811132 DOI: 10.1016/j.aca.2024.342692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 04/30/2024] [Accepted: 05/03/2024] [Indexed: 05/31/2024]
Affiliation(s)
- Qiushuang Yang
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China; University of Chinese Academy of Sciences, Beijing 100049, China; State Key Laboratory of Applied Optics, Changchun, Jilin 130033, China; Key Laboratory of Optical System Advanced Manufacturing Technology, Chinese Academy of Sciences, Changchun, Jilin 130033, China
| | - Wenchao Zhou
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China; State Key Laboratory of Applied Optics, Changchun, Jilin 130033, China; Key Laboratory of Optical System Advanced Manufacturing Technology, Chinese Academy of Sciences, Changchun, Jilin 130033, China.
| | - Huan Li
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China; State Key Laboratory of Applied Optics, Changchun, Jilin 130033, China; Key Laboratory of Optical System Advanced Manufacturing Technology, Chinese Academy of Sciences, Changchun, Jilin 130033, China
| | - Jialing Huang
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang 325035, China
| | - Zeyuan Song
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China; University of Chinese Academy of Sciences, Beijing 100049, China; State Key Laboratory of Applied Optics, Changchun, Jilin 130033, China; Key Laboratory of Optical System Advanced Manufacturing Technology, Chinese Academy of Sciences, Changchun, Jilin 130033, China
| | - Long Cheng
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China; University of Chinese Academy of Sciences, Beijing 100049, China; State Key Laboratory of Applied Optics, Changchun, Jilin 130033, China; Key Laboratory of Optical System Advanced Manufacturing Technology, Chinese Academy of Sciences, Changchun, Jilin 130033, China
| | - Yihui Wu
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China; State Key Laboratory of Applied Optics, Changchun, Jilin 130033, China; Key Laboratory of Optical System Advanced Manufacturing Technology, Chinese Academy of Sciences, Changchun, Jilin 130033, China.
| | - Deqiang Mu
- Changchun University of Technology, Changchun, Jilin 130012, China
| |
Collapse
|
2
|
Trinh TND, Lee NY. Colorimetric detection of viable antibiotic resistant Enterococcus mediated by cordless operation of reverse transcription loop-mediated isothermal amplification. J Biotechnol 2022; 357:92-99. [PMID: 35952900 DOI: 10.1016/j.jbiotec.2022.08.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Revised: 07/12/2022] [Accepted: 08/05/2022] [Indexed: 11/20/2022]
Abstract
In this study, we applied a tube-based reverse transcription loop-mediated isothermal amplification technique using preloaded amplification and detection reagents for simple screening of viable vancomycin-resistant Enterococcus in a cordless manner. We adopted an mRNA-based approach to detect live Enterococcus in vancomycin-treated cultures. We used agarose to preload and store all reagents for amplification and detection inside the tube, which could achieve on-site isothermal nucleic acid amplification and detection in less than 1 h without using sophisticated instruments. Moreover, the use of a portable insulated water tumbler eliminated the need for electricity, which is usually important in nucleic acid amplification-based assays. The water tumbler acted as a heat source to supply a stable heat required for the amplification reaction, which could last up to 45 min. In addition, colorimetric detection was realized using pH-based methods. The detection was triggered by shaking the tube so that the amplified solution was reacted with phenolphthalein embedded in the tube cap. The introduced one-pot strategy has many advantages such as easy and cordless operation, low cost, disposability, and less chance of contamination because the amplification and detection occur in a closed system. The system could have a great impact on nucleic acid analyses in instrument-free and low-resource areas.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, the Republic of Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, the Republic of Korea.
| |
Collapse
|
3
|
Chen JJ, Lin ZH. Fabrication of an Oscillating Thermocycler to Analyze the Canine Distemper Virus by Utilizing Reverse Transcription Polymerase Chain Reaction. MICROMACHINES 2022; 13:mi13040600. [PMID: 35457905 PMCID: PMC9026093 DOI: 10.3390/mi13040600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 03/29/2022] [Accepted: 04/11/2022] [Indexed: 02/04/2023]
Abstract
The reverse transcription-polymerase chain reaction (RT-PCR) has been utilized as an effective tool to diagnose the infectious diseases of viruses. In the present work, the oscillating thermocycler is fabricated and performed to carry out the one-step RT-PCR process successfully. The ribonucleic acid (RNA) mixture is pipetted into the fixed sample volume inside an aluminum reaction block. The sample oscillates the pathway onto the linear motion control system and through the specific RT-PCR heating zones with individual homemade thermal control modules. The present oscillating thermocycler combines the merits of the chamber type and the CF type systems. Before PCR, the reaction chamber moves to the low-temperature zone to complete the RT stage and synthesize the complementary deoxyribonucleic acid (DNA). Next, the low-temperature zone is regulated to the annealing zone. Furthermore, the reactive sample is moved back and forth among three isothermal zones to complete PCR. No extra heating zone is required for the RT stage. The total length of the moving displacement of the chamber is within 100 mm. The miniaturization of the oscillating thermocycler can be expected. In our oscillatory device, the denaturation zone located between the annealing and extension zones is suggested as the appropriate arrangement of the heating blocks. Heat management without thermal cross-talk is easy. Finally, an improved oscillating device is demonstrated to execute the RT-PCR process directly, utilized to amplify the canine distemper virus templates successfully, which could be well applied to a low-cost DNA analysis system in the future.
Collapse
|
4
|
Trinh TND, Lee NY. Nucleic acid amplification-based microfluidic approaches for antimicrobial susceptibility testing. Analyst 2021; 146:3101-3113. [PMID: 33876805 DOI: 10.1039/d1an00180a] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Because of the global spread of antimicrobials, there is an urgent need to develop rapid and effective tools for antimicrobial susceptibility testing to help clinicians prescribe accurate and appropriate antibiotic doses sooner. The conventional methods for antimicrobial susceptibility testing are usually based on bacterial culture methods, which are time-consuming, complicated, and labor-intensive. Therefore, other approaches are needed to address these issues. Recently, microfluidic technology has gained significant attention in infection management due to its advantages including rapid detection, high sensitivity and specificity, highly automated assay, simplicity, low cost, and potential for point-of-care testing in low-resource areas. Microfluidic advances for antimicrobial susceptibility testing can be classified into phenotypic (usually culture-based) and genotypic tests. Genotypic antimicrobial susceptibility testing is the detection of resistant genes in a microorganism using methods such as nucleic acid amplification. This review (with 107 references) surveys the different forms of nucleic acid amplification-based microdevices used for genotypic antimicrobial susceptibility testing. The first section reviews the serious threat of antimicrobial-resistant microorganisms and the urgent need for fast check-ups. Next, several conventional antimicrobial susceptibility testing methods are discussed, and microfluidic technology as a promising candidate for rapid detection of antimicrobial-resistant microorganisms is briefly introduced. The next section highlights several advancements of microdevices, with an emphasis on their working principles and performance. The review concludes with the importance of fully integrated microdevices and a discussion on future perspectives.
Collapse
Affiliation(s)
- Thi Ngoc Diep Trinh
- Department of Industrial Environmental Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do 13120, Korea.
| |
Collapse
|