1
|
Lyu N, Hassanzadeh-Barforoushi A, Rey Gomez LM, Zhang W, Wang Y. SERS biosensors for liquid biopsy towards cancer diagnosis by detection of various circulating biomarkers: current progress and perspectives. NANO CONVERGENCE 2024; 11:22. [PMID: 38811455 PMCID: PMC11136937 DOI: 10.1186/s40580-024-00428-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 05/09/2024] [Indexed: 05/31/2024]
Abstract
Liquid biopsy has emerged as a promising non-invasive strategy for cancer diagnosis, enabling the detection of various circulating biomarkers, including circulating tumor cells (CTCs), circulating tumor nucleic acids (ctNAs), circulating tumor-derived small extracellular vesicles (sEVs), and circulating proteins. Surface-enhanced Raman scattering (SERS) biosensors have revolutionized liquid biopsy by offering sensitive and specific detection methodologies for these biomarkers. This review comprehensively examines the application of SERS-based biosensors for identification and analysis of various circulating biomarkers including CTCs, ctNAs, sEVs and proteins in liquid biopsy for cancer diagnosis. The discussion encompasses a diverse range of SERS biosensor platforms, including label-free SERS assay, magnetic bead-based SERS assay, microfluidic device-based SERS system, and paper-based SERS assay, each demonstrating unique capabilities in enhancing the sensitivity and specificity for detection of liquid biopsy cancer biomarkers. This review critically assesses the strengths, limitations, and future directions of SERS biosensors in liquid biopsy for cancer diagnosis.
Collapse
Affiliation(s)
- Nana Lyu
- School of Natural Sciences, Macquarie University, Sydney, NSW, 2109, Australia
| | | | - Laura M Rey Gomez
- School of Natural Sciences, Macquarie University, Sydney, NSW, 2109, Australia
| | - Wei Zhang
- School of Natural Sciences, Macquarie University, Sydney, NSW, 2109, Australia
| | - Yuling Wang
- School of Natural Sciences, Macquarie University, Sydney, NSW, 2109, Australia.
| |
Collapse
|
2
|
Yang S, Wang D, Zhao Z, Wang N, Yu M, Zhang K, Luo Y, Zhao J. A Novel DNA Synthesis Platform Design with High-Throughput Paralleled Addressability and High-Density Static Droplet Confinement. BIOSENSORS 2024; 14:177. [PMID: 38667170 PMCID: PMC11047993 DOI: 10.3390/bios14040177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 04/04/2024] [Accepted: 04/04/2024] [Indexed: 04/28/2024]
Abstract
Using DNA as the next-generation medium for data storage offers unparalleled advantages in terms of data density, storage duration, and power consumption as compared to existing data storage technologies. To meet the high-speed data writing requirements in DNA data storage, this paper proposes a novel design for an ultra-high-density and high-throughput DNA synthesis platform. The presented design mainly leverages two functional modules: a dynamic random-access memory (DRAM)-like integrated circuit (IC) responsible for electrode addressing and voltage supply, and the static droplet array (SDA)-based microfluidic structure to eliminate any reaction species diffusion concern in electrochemical DNA synthesis. Through theoretical analysis and simulation studies, we validate the effective addressing of 10 million electrodes and stable, adjustable voltage supply by the integrated circuit. We also demonstrate a reaction unit size down to 3.16 × 3.16 μm2, equivalent to 10 million/cm2, that can rapidly and stably generate static droplets at each site, effectively constraining proton diffusion. Finally, we conducted a synthesis cycle experiment by incorporating fluorescent beacons on a microfabricated electrode array to examine the feasibility of our design.
Collapse
Affiliation(s)
- Shijia Yang
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (S.Y.); (D.W.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Dayin Wang
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (S.Y.); (D.W.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China
| | - Zequan Zhao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (S.Y.); (D.W.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ning Wang
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (S.Y.); (D.W.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China
| | - Meng Yu
- School of Microelectronics, Shanghai University, Shanghai 200444, China
| | - Kaihuan Zhang
- 2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China;
| | - Yuan Luo
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (S.Y.); (D.W.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jianlong Zhao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China; (S.Y.); (D.W.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
3
|
Wu J, Fang H, Zhang J, Yan S. Modular microfluidics for life sciences. J Nanobiotechnology 2023; 21:85. [PMID: 36906553 PMCID: PMC10008080 DOI: 10.1186/s12951-023-01846-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 03/06/2023] [Indexed: 03/13/2023] Open
Abstract
The advancement of microfluidics has enabled numerous discoveries and technologies in life sciences. However, due to the lack of industry standards and configurability, the design and fabrication of microfluidic devices require highly skilled technicians. The diversity of microfluidic devices discourages biologists and chemists from applying this technique in their laboratories. Modular microfluidics, which integrates the standardized microfluidic modules into a whole, complex platform, brings the capability of configurability to conventional microfluidics. The exciting features, including portability, on-site deployability, and high customization motivate us to review the state-of-the-art modular microfluidics and discuss future perspectives. In this review, we first introduce the working mechanisms of the basic microfluidic modules and evaluate their feasibility as modular microfluidic components. Next, we explain the connection approaches among these microfluidic modules, and summarize the advantages of modular microfluidics over integrated microfluidics in biological applications. Finally, we discuss the challenge and future perspectives of modular microfluidics.
Collapse
Affiliation(s)
- Jialin Wu
- Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, China
- Nanophotonics Research Center, Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, China
| | - Hui Fang
- Nanophotonics Research Center, Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, China
| | - Jun Zhang
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Sheng Yan
- Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, China.
| |
Collapse
|
4
|
Yang H, Jiang L, Guo K, Xiang N. Static droplet array for the synthesis of nonspherical microparticles. Electrophoresis 2023; 44:563-572. [PMID: 36593724 DOI: 10.1002/elps.202200271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/20/2022] [Accepted: 12/25/2022] [Indexed: 01/04/2023]
Abstract
We reported a manually operated static droplet array (SDA)-based device for the synthesis of nonspherical microparticles with different shapes. The improved SDA structure and reversible bonding between poly(dimethylsiloxane) (PDMS) were used in the device for the large-scale synthesis and rapid extraction of nonspherical microparticles. To understand the device physics, the effects of flow rate, SDA well size, and shape on droplet generation performances were explored. The results indicated that droplet generation in SDA structures was insensitive to the flow rate, and monodisperse droplets were generated by the SDA-based device through manually pushing the syringe. Finally, we integrated four kinds of SDA structures in one device and successfully realized the synthesis and extraction of nonspherical microparticles with different shapes and materials. Our SDA-based device offers numerous advantages, such as simple manual operation, low equipment cost, controllable microparticle shapes and sizes, and large-scale production. Thus, it holds the potential to be used as a flexible tool for the production of nonspherical microparticles.
Collapse
Affiliation(s)
- Hang Yang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Lin Jiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Kefan Guo
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| |
Collapse
|
5
|
Rapid metabolomic screening of cancer cells via high-throughput static droplet microfluidics. Biosens Bioelectron 2023; 223:114966. [PMID: 36580816 DOI: 10.1016/j.bios.2022.114966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 11/26/2022] [Accepted: 11/27/2022] [Indexed: 12/23/2022]
Abstract
Effective isolation and in-depth analysis of Circulating Tumour Cells (CTCs) are greatly needed in diagnosis, prognosis and monitoring of the therapeutic response of cancer patients but have not been completely fulfilled by conventional approaches. The rarity of CTCs and the lack of reliable biomarkers to distinguish them from peripheral blood cells have remained outstanding challenges for their clinical implementation. Herein, we developed a high throughput Static Droplet Microfluidic (SDM) device with 38,400 chambers, capable of isolating and classifying the number of metabolically active CTCs in peripheral blood at single-cell resolution. Owing to the miniaturisation and compartmentalisation capability of our device, we first demonstrated the ability to precisely measure the lactate production of different types of cancer cells inside 125 pL droplets at single-cell resolution. Furthermore, we compared the metabolomic activity of leukocytes from healthy donors to cancer cells and showed the ability to differentiate them. To further prove the clinical relevance, we spiked cancer cell lines in human healthy blood and showed the possibility to detect the cancer cells from leukocytes. Lastly, we tested the workflow on 8 preclinical mammary mouse models including syngeneic 67NR (non-metastatic) and 4T1.2 (metastatic) models with Triple-Negative Breast Cancer (TNBC) as well as transgenic mouses (12-week-old MMTV-PyMT). The results have shown the ability to precisely distinguish metabolically active CTCs from the blood using the proposed SDM device. The workflow is simple and robust which can eliminate the need for specialised equipment and expertise required for single-cell analysis of CTCs and facilitate on-site metabolic screening of cancer cells.
Collapse
|
6
|
Soozanipour A, Ejeian F, Boroumand Y, Rezayat A, Moradi S. Biotechnological advancements towards water, food and medical healthcare: A review. CHEMOSPHERE 2023; 312:137185. [PMID: 36368538 DOI: 10.1016/j.chemosphere.2022.137185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Revised: 10/21/2022] [Accepted: 11/05/2022] [Indexed: 06/16/2023]
Abstract
The global health status is highly affected by the growing pace of urbanization, new lifestyles, climate changes, and resource exploitation. Modern technologies pave a promising way to deal with severe concerns toward sustainable development. Herein, we provided a comprehensive review of some popular biotechnological advancements regarding the progress achieved in water, food, and medicine, as the most substantial fields related to public health. The emergence of novel organic/inorganic materials has brought about significant improvement in conventional water treatment techniques, anti-fouling approaches, anti-microbial agents, food processing, biosensors, drug delivery systems, and implants. Particularly, a growing interest has been devoted to nanomaterials and their application for developing novel structures or improving the characteristics of standard components. Also, bioinspired materials have been widely used to improve the performance, efficiency, accuracy, stability, safety, and cost-effectiveness of traditional systems. On the other side, the fabrication of innovative devices for precisely monitoring and managing various ecosystem and human health issues is of great importance. Above all, exceptional advancements in designing ion-selective electrodes (ISEs), microelectromechanical systems (MEMs), and implantable medical devices have altered the future landscape of environmental and biomedical research. This review paper aimed to shed light on the wide-ranging materials and devices that have been developed for health applications and mainly focused on the impact of nanotechnology in this field.
Collapse
Affiliation(s)
- Asieh Soozanipour
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 81746-73441, Iran
| | - Fatemeh Ejeian
- Department of Animal Biotechnology, Cell Science Research Center, Royan Institute for Biotechnology, ACECR, Isfahan, Iran.
| | - Yasaman Boroumand
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 81746-73441, Iran
| | - Azam Rezayat
- Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 81746-73441, Iran; Department of Chemistry, Faculty of Science, Lorestan University, Khorramabad, 68151-44316, Iran
| | - Sina Moradi
- School of Chemical Engineering, University of New South Wales, Sydney, 2052, Australia; Artificial Intelligence Centre of Excellence (AI CoE), NCSI Australia, Sydney, NSW, 2113, Australia.
| |
Collapse
|
7
|
Koch EV, Ledwig V, Bendas S, Reichl S, Dietzel A. Tissue Barrier-on-Chip: A Technology for Reproducible Practice in Drug Testing. Pharmaceutics 2022; 14:pharmaceutics14071451. [PMID: 35890346 PMCID: PMC9323870 DOI: 10.3390/pharmaceutics14071451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 06/29/2022] [Accepted: 07/07/2022] [Indexed: 12/03/2022] Open
Abstract
One key application of organ-on-chip systems is the examination of drug transport and absorption through native cell barriers such the blood–brain barrier. To overcome previous hurdles related to the transferability of existing static cell cultivation protocols and polydimethylsiloxane (PDMS) as the construction material, a chip platform with key innovations for practical use in drug-permeation testing is presented. First, the design allows for the transfer of barrier-forming tissue into the microfluidic system after cells have been seeded on porous polymer or Si3N4 membranes. From this, we can follow highly reproducible models and cultivation protocols established for static drug testing, from coating the membrane to seeding the cells and cell analysis. Second, the perfusion system is a microscopable glass chip with two fluid compartments with transparent embedded electrodes separated by the membrane. The reversible closure in a clamping adapter requires only a very thin PDMS sealing with negligible liquid contact, thereby eliminating well-known disadvantages of PDMS, such as its limited usability in the quantitative measurements of hydrophobic drug molecule concentrations. Equipped with tissue transfer capabilities, perfusion chamber inertness and air bubble trapping, and supplemented with automated fluid control, the presented system is a promising platform for studying established in vitro models of tissue barriers under reproducible microfluidic perfusion conditions.
Collapse
Affiliation(s)
- Eugen V. Koch
- Institute of Microtechnology, TU Braunschweig, Alte Salzdahlumer Str. 203, 38124 Braunschweig, Germany;
- Center of Pharmaceutical Engineering (PVZ), TU Braunschweig, Franz-Liszt-Straße 35 A, 38106 Braunschweig, Germany; (V.L.); (S.B.); (S.R.)
- Correspondence: ; Tel.: +49-0531-391-9788
| | - Verena Ledwig
- Center of Pharmaceutical Engineering (PVZ), TU Braunschweig, Franz-Liszt-Straße 35 A, 38106 Braunschweig, Germany; (V.L.); (S.B.); (S.R.)
- Institute of Pharmaceutical Technology and Biopharmaceutics, TU Braunschweig, Mendelssohnstrasse 1, 38106 Braunschweig, Germany
| | - Sebastian Bendas
- Center of Pharmaceutical Engineering (PVZ), TU Braunschweig, Franz-Liszt-Straße 35 A, 38106 Braunschweig, Germany; (V.L.); (S.B.); (S.R.)
- Institute of Pharmaceutical Technology and Biopharmaceutics, TU Braunschweig, Mendelssohnstrasse 1, 38106 Braunschweig, Germany
| | - Stephan Reichl
- Center of Pharmaceutical Engineering (PVZ), TU Braunschweig, Franz-Liszt-Straße 35 A, 38106 Braunschweig, Germany; (V.L.); (S.B.); (S.R.)
- Institute of Pharmaceutical Technology and Biopharmaceutics, TU Braunschweig, Mendelssohnstrasse 1, 38106 Braunschweig, Germany
| | - Andreas Dietzel
- Institute of Microtechnology, TU Braunschweig, Alte Salzdahlumer Str. 203, 38124 Braunschweig, Germany;
- Center of Pharmaceutical Engineering (PVZ), TU Braunschweig, Franz-Liszt-Straße 35 A, 38106 Braunschweig, Germany; (V.L.); (S.B.); (S.R.)
| |
Collapse
|
8
|
Abstract
Microfluidics has enabled a new era of cellular and molecular assays due to the small length scales, parallelization, and the modularity of various analysis and actuation functions. Droplet microfluidics, in particular, has been instrumental in providing new tools for biology with its ability to quickly and reproducibly generate drops that act as individual reactors. A notable beneficiary of this technology has been single-cell RNA sequencing, which has revealed new heterogeneities and interactions for the fundamental unit of life. However, viruses far surpass the diversity of cellular life, affect the dynamics of all ecosystems, and are a chronic source of global health crises. Despite their impact on the world, high-throughput and high-resolution viral profiling has been difficult, with conventional methods being limited to population-level averaging, large sample volumes, and few cultivable hosts. Consequently, most viruses have not been identified and studied. Droplet microfluidics holds the potential to address many of these limitations and offers new levels of sensitivity and throughput for virology. This Feature highlights recent efforts that have applied droplet microfluidics to the detection and study of viruses, including for diagnostics, virus-host interactions, and cell-independent virus assays. In combination with traditional virology methods, droplet microfluidics should prove a potent tool toward achieving a better understanding of the most abundant biological species on Earth.
Collapse
Affiliation(s)
- Wenyang Jing
- Center for Biophysics and Quantitative Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Hee-Sun Han
- Center for Biophysics and Quantitative Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 West Gregory Drive, Urbana, Illinois 61801, United States
| |
Collapse
|
9
|
Kim S, Song H, Ahn H, Kim T, Jung J, Cho SK, Shin DM, Choi JR, Hwang YH, Kim K. A Review of Advanced Impedance Biosensors with Microfluidic Chips for Single-Cell Analysis. BIOSENSORS 2021; 11:412. [PMID: 34821628 PMCID: PMC8615569 DOI: 10.3390/bios11110412] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 10/09/2021] [Accepted: 10/20/2021] [Indexed: 05/25/2023]
Abstract
Electrical impedance biosensors combined with microfluidic devices can be used to analyze fundamental biological processes for high-throughput analysis at the single-cell scale. These specialized analytical tools can determine the effectiveness and toxicity of drugs with high sensitivity and demonstrate biological functions on a single-cell scale. Because the various parameters of the cells can be measured depending on methods of single-cell trapping, technological development ultimately determine the efficiency and performance of the sensors. Identifying the latest trends in single-cell trapping technologies afford opportunities such as new structural design and combination with other technologies. This will lead to more advanced applications towards improving measurement sensitivity to the desired target. In this review, we examined the basic principles of impedance sensors and their applications in various biological fields. In the next step, we introduced the latest trend of microfluidic chip technology for trapping single cells and summarized the important findings on the characteristics of single cells in impedance biosensor systems that successfully trapped single cells. This is expected to be used as a leading technology in cell biology, pathology, and pharmacological fields, promoting the further understanding of complex functions and mechanisms within individual cells with numerous data sampling and accurate analysis capabilities.
Collapse
Affiliation(s)
- Soojung Kim
- Departments of Congo-Mechatronics Engineering, Pusan National University, Busan 46241, Korea; (S.K.); (H.S.); (H.A.); (T.K.); (J.J.)
| | - Hyerin Song
- Departments of Congo-Mechatronics Engineering, Pusan National University, Busan 46241, Korea; (S.K.); (H.S.); (H.A.); (T.K.); (J.J.)
| | - Heesang Ahn
- Departments of Congo-Mechatronics Engineering, Pusan National University, Busan 46241, Korea; (S.K.); (H.S.); (H.A.); (T.K.); (J.J.)
| | - Taeyeon Kim
- Departments of Congo-Mechatronics Engineering, Pusan National University, Busan 46241, Korea; (S.K.); (H.S.); (H.A.); (T.K.); (J.J.)
| | - Jihyun Jung
- Departments of Congo-Mechatronics Engineering, Pusan National University, Busan 46241, Korea; (S.K.); (H.S.); (H.A.); (T.K.); (J.J.)
| | - Soo Kyung Cho
- Division of Nano Convergence Technology, Pusan National University (PNU), Miryang 50463, Korea;
| | - Dong-Myeong Shin
- Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong 999077, China;
| | - Jong-ryul Choi
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation (DGMIF), Daegu 41061, Korea;
| | - Yoon-Hwae Hwang
- Department of Nano Energy Engineering, Pusan National University (PNU), Busan 46241, Korea
| | - Kyujung Kim
- Departments of Congo-Mechatronics Engineering, Pusan National University, Busan 46241, Korea; (S.K.); (H.S.); (H.A.); (T.K.); (J.J.)
- Department of Optics and Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| |
Collapse
|
10
|
Thakur S, Dasmahapatra AK, Bandyopadhyay D. Functional liquid droplets for analyte sensing and energy harvesting. Adv Colloid Interface Sci 2021; 294:102453. [PMID: 34120038 DOI: 10.1016/j.cis.2021.102453] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 05/25/2021] [Accepted: 05/25/2021] [Indexed: 02/06/2023]
Abstract
Over the past century, rapid miniaturization of technologies has helped in the development of efficient, flexible, portable, robust, and compact applications with minimal wastage of materials. In this direction, of late, the usage of mesoscale liquid droplets has emerged as an alternative platform because of the following advantages: (i) a droplet is incompressible and at the same time deformable, (ii) interfacial area of a spherical droplet is minimum for a given amount of mass; and (iii) a droplet interface allows facile mass, momentum, and energy transfer. Subsequently, such attributes have aided towards the design of diverse droplet-based microfluidic technologies. For example, the microdroplets have been utilized as micro-reactors, colorimetric or electrochemical (EC) sensors, drug-delivery vehicles, and energy harvesters. Further, a number of recently reported lab-on-a-chip technologies exploit the motility, storage, and mixing capacities of the microdroplets. In view of this background, the review initiates discussion by highlighting the different attributes of the microdroplets such as size, shape, surface to volume ratio, wettability, and contact line. Thereafter, the effects of the surface or body forces on the properties of the droplets have been elaborated. Finally, the different aspects of such liquid droplet systems towards technological adaptations in health care, sensing, and energy harvesting have been presented. The review concludes with a tight summary on the potential avenues for further developments.
Collapse
Affiliation(s)
- Siddharth Thakur
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India
| | - Ashok Kumar Dasmahapatra
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India; Centre for Nanotechnology, Indian Institute of Technology Guwahati, Assam 781039, India
| | - Dipankar Bandyopadhyay
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India; Centre for Nanotechnology, Indian Institute of Technology Guwahati, Assam 781039, India.
| |
Collapse
|
11
|
An easy-to-operate method for single-cell isolation and retrieval using a microfluidic static droplet array. Mikrochim Acta 2021; 188:242. [PMID: 34226955 DOI: 10.1007/s00604-021-04897-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 06/12/2021] [Indexed: 10/20/2022]
Abstract
In-depth study of cellular heterogeneity of rare cells (e.g. circulating tumour cells (CTCs) and circulating foetal cells (CFCs)) is greatly needed in disease management but has never been completely explored due to the current technological limitations. We have developed a retrieval method for single-cell detection using a static droplet array (SDA) device through liquid segmentation with almost no sample loss. We explored the potential of using SDA for low sample input and retrieving the cells of interest using everyday laboratory equipment for downstream molecular analysis. This single-cell isolation and retrieval method is low-cost, rapid and provides a solution to the remaining challenge for single rare cell detection. The entire process takes less than 15 min, is easy to fabricate and allows for on-chip analysis of cells in nanolitre droplets and retrieval of desired droplets. To validate the applicability of our device and method, we mimicked detection of single CTCs by isolating and retrieving single cells and perform real-time PCR on their mRNA contents.
Collapse
|
12
|
Rezaei M, Radfar P, Winter M, McClements L, Thierry B, Warkiani ME. Simple-to-Operate Approach for Single Cell Analysis Using a Hydrophobic Surface and Nanosized Droplets. Anal Chem 2021; 93:4584-4592. [PMID: 33656329 DOI: 10.1021/acs.analchem.0c05026] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Microfluidics-based technologies for single-cell analysis are becoming increasingly important tools in biological studies. With the increasing sophistication of microfluidics, cellular barcoding techniques, and next-generation sequencing, a more detailed picture of cellular subtype is emerging. Unfortunately, the majority of the methods developed for single-cell analysis are high-throughput and not suitable for rare cell analysis as they require a high input cell number. Here, we report a low-cost and reproducible method for rare single-cell analysis using a highly hydrophobic surface and nanosized static droplets. Our method allows rapid and efficient on-chip single-cell lysis and subsequent collection of genetic materials in nanoliter droplets using a micromanipulator or a laboratory pipette before subsequent genetic analysis. We show precise isolation of single cancer cells with high purity using two different strategies (i- cytospin and ii- static droplet array) for subsequent RNA analysis using droplet digital polymerase chain reaction (PCR) and real-time PCR. Our highly controlled isolation method opens a new avenue for the study of subcellular functional mechanisms, enabling the identification of rare cells of potential functional or pathogenic consequence.
Collapse
Affiliation(s)
- Meysam Rezaei
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales, 2007, Australia.,Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, New South Wales 2007, Australia.,SUStech-UTS Joint Research Centre for Biomedical Materials and Devices, Southern University of Science and Technology, Shenzhen 518055, People's Republic of China
| | - Payar Radfar
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales, 2007, Australia
| | - Marnie Winter
- Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, South Australia 5095, Australia
| | - Lana McClements
- School of Life Sciences, University of Technology Sydney, Sydney, New South Wales, 2007, Australia
| | - Benjamin Thierry
- Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, South Australia 5095, Australia
| | - Majid Ebrahimi Warkiani
- School of Biomedical Engineering, University of Technology Sydney, Sydney, New South Wales, 2007, Australia.,Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, New South Wales 2007, Australia.,SUStech-UTS Joint Research Centre for Biomedical Materials and Devices, Southern University of Science and Technology, Shenzhen 518055, People's Republic of China.,Institute of Molecular Medicine, Sechenov University, Moscow 119991, Russia
| |
Collapse
|
13
|
Wu W, Zhang S, Zhang T, Mu Y. Immobilized Droplet Arrays in Thermosetting Oil for Dynamic Proteolytic Assays of Single Cells. ACS APPLIED MATERIALS & INTERFACES 2021; 13:6081-6090. [PMID: 33504155 DOI: 10.1021/acsami.0c21696] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Matrix metalloproteinases (MMPs) play an important role in tumor progression. The study of dynamic MMPs activity at the single-cell level can dissect tumor heterogeneity in the time domain and facilitate finding out more efficient clinical solutions for tumor treatment. Due to the fluidity of the carrier oil, the existing droplet-based methods for single-cell MMP analysis rarely have the capability to track proteolytic assays in droplets continuously. Therefore, we describe a thermosetting oil for real-time monitoring of MMP assays in droplets, which can immobilize droplets by transforming into solid after droplet generation. The solidification of this oil can be accomplished in 33 min at 37 °C, basing on the hydrosilation of vinyl silicone oil and hydrosilicone oil without other inducers (e.g. UV, Ca2+). Through monitoring the MMP assays of single cells, the reaction rates can be calculated according to real-time fluorescent curves, showing significant cell heterogeneity in MMP activity. Moreover, the dynamic MMP activity reveals that some of the A549 cells transiently secrete MMP. In conclusion, the thermosetting oil enables immobilize droplets to achieve real-time monitoring of single-cell proteolytic activity without impairing the flexibility of droplet microfluidics and has a potential in other cell-based assays for providing dynamic information at high resolutions.
Collapse
Affiliation(s)
- Wenshuai Wu
- Research Center for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, P. R. China
- College of Life Sciences, Zhejiang University, Hangzhou 310058, P. R. China
| | - Shan Zhang
- Research Center for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, P. R. China
- College of Life Sciences, Zhejiang University, Hangzhou 310058, P. R. China
| | - Tao Zhang
- Research Center for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, P. R. China
| | - Ying Mu
- Research Center for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, P. R. China
| |
Collapse
|
14
|
Recent Development of Microfluidic Technology for Cell Trapping in Single Cell Analysis: A Review. Processes (Basel) 2020. [DOI: 10.3390/pr8101253] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Microfluidic technology has emerged from the MEMS (Micro-Electro-Mechanical System)-technology as an important research field. During the last decade, various microfluidic technologies have been developed to open up a new era for biological studies. To understand the function of single cells, it is very important to monitor the dynamic behavior of a single cell in a living environment. Cell trapping in single cell analysis is urgently demanded There have been some review papers focusing on drug screen and cell analysis. However, cell trapping in single cell analysis has rarely been covered in the previous reviews. The present paper focuses on recent developments of cell trapping and highlights the mechanisms, governing equations and key parameters affecting the cell trapping efficiency by contact-based and contactless approach. The applications of the cell trapping method are discussed according to their basic research areas, such as biology and tissue engineering. Finally, the paper highlights the most promising cell trapping method for this research area.
Collapse
|
15
|
Sheikh Z, Bradbury P, Pozzoli M, Young PM, Ong HX, Traini D. An in vitro model for assessing drug transport in cystic fibrosis treatment: Characterisation of the CuFi-1 cell line. Eur J Pharm Biopharm 2020; 156:121-130. [PMID: 32916267 DOI: 10.1016/j.ejpb.2020.09.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 07/10/2020] [Accepted: 09/01/2020] [Indexed: 01/01/2023]
Abstract
Cystic fibrosis (CF) is a disease that most commonly affects the lungs and is characterized by mucus retention and a continuous cycle of bacterial infection and inflammation. Current CF treatment strategies are focused on targeted drug delivery to the lungs. Novel inhalable drug therapies require an in vitro CF model that appropriately mimics the in vivo CF lung environment to better understand drug delivery and transport across the CF epithelium, and predict drug therapeutic efficacy. Therefore, the aim of this research was to determine the appropriate air-liquid interface (ALI) culture method of the CuFi-1 (CF cell line) compared to the NuLi-1 (healthy cell line) cells to be used as in vitro models of CF airway epithelia. Furthermore, drug transport on both CuFi-1 and NuLi-1 was investigated to determine whether these cell lines could be used to study transport of drugs used in CF treatment using Ibuprofen (the only anti-inflammatory drug currently approved for CF) as a model drug. Differentiating characteristics specific to airway epithelia such as mucus production, inflammatory response and tight junction formation at two seeding densities (Low and High) were assessed throughout an 8-week ALI culture period. This study demonstrated that both the NuLi-1 and CuFi-1 cell lines fully differentiate in ALI culture with significant mucus secretion, IL-6 and IL-8 production, and functional tight junctions at week 8. Additionally, the High seeding density was found to alter the phenotype of the NuLi-1 cell line. For the first time, this study identifies that ibuprofen is transported via the paracellular pathway in ALI models of NuLi-1 and CuFi-1 cell lines. Overall, these findings highlight that NuLi-1 and CuFi-1 as promising in vitro ALI models to investigate the transport properties of novel inhalable drug therapies for CF treatment.
Collapse
Affiliation(s)
- Zara Sheikh
- Respiratory Technology, The Woolcock Institute of Medical Research, Glebe, Australia; Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia
| | - Peta Bradbury
- Respiratory Technology, The Woolcock Institute of Medical Research, Glebe, Australia; Discipline of Medicine, Central Clinical School, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia
| | - Michele Pozzoli
- Respiratory Technology, The Woolcock Institute of Medical Research, Glebe, Australia
| | - Paul M Young
- Respiratory Technology, The Woolcock Institute of Medical Research, Glebe, Australia; Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia
| | - Hui Xin Ong
- Respiratory Technology, The Woolcock Institute of Medical Research, Glebe, Australia; Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
| | - Daniela Traini
- Respiratory Technology, The Woolcock Institute of Medical Research, Glebe, Australia; Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
| |
Collapse
|
16
|
Rho HS, Gardeniers H. Microfluidic Droplet-Storage Array. MICROMACHINES 2020; 11:mi11060608. [PMID: 32585943 PMCID: PMC7344826 DOI: 10.3390/mi11060608] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 06/19/2020] [Accepted: 06/22/2020] [Indexed: 01/22/2023]
Abstract
A microfluidic droplet-storage array that is capable of the continuous operation of droplet formation, storing, repositioning, retrieving, injecting and restoring is demonstrated. The microfluidic chip comprised four valve-assisted droplet generators and a 3 × 16 droplet-storage array. The integrated pneumatically actuated microvalves enable the precise control of aqueous phase dispensing, as well as carrier fluid flow path and direction for flexible manipulating water-in-oil droplets in the chip. The size of droplets formed by the valve-assisted droplet generators was validated under various operating conditions such as pressures for introducing solutions and dispensing time. In addition, flexible droplet addressing in the storage array was demonstrated by storing droplets with various numbers and compositions in different storage units as well as rearranging their stored positions. Moreover, serial injections of new droplets into a retrieved droplet from a storage unit was performed to show the potential of the platform in sequential dosing on incubated droplet-based reactors at the desired timeline. The droplet-storage array with great freedom and flexibility in droplet handling could be applied for performing complex chemical and biologic reactions, especially in which incubation and dosing steps are necessary.
Collapse
Affiliation(s)
- Hoon Suk Rho
- Department of Instructive Biomaterials Engineering, MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, 6229 ER Maastricht, The Netherlands;
- Mesoscale Chemical Systems Group, MESA+ Institute, University of Twente, 7522 NB Enschede, The Netherlands
| | - Han Gardeniers
- Mesoscale Chemical Systems Group, MESA+ Institute, University of Twente, 7522 NB Enschede, The Netherlands
- Correspondence: ; Tel.: +31-(0)53-489-4356
| |
Collapse
|
17
|
Capillary-assisted microfluidic biosensing platform captures single cell secretion dynamics in nanoliter compartments. Biosens Bioelectron 2020; 155:112113. [DOI: 10.1016/j.bios.2020.112113] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 02/06/2020] [Accepted: 02/18/2020] [Indexed: 02/07/2023]
|
18
|
Nagai M, Kato K, Soga S, Santra TS, Shibata T. Scalable Parallel Manipulation of Single Cells Using Micronozzle Array Integrated with Bidirectional Electrokinetic Pumps. MICROMACHINES 2020; 11:mi11040442. [PMID: 32331468 PMCID: PMC7231381 DOI: 10.3390/mi11040442] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 04/17/2020] [Accepted: 04/22/2020] [Indexed: 12/27/2022]
Abstract
High throughput reconstruction of in vivo cellular environments allows for efficient investigation of cellular functions. If one-side-open multi-channel microdevices are integrated with micropumps, the devices will achieve higher throughput in the manipulation of single cells while maintaining flexibility and open accessibility. This paper reports on the integration of a polydimethylsiloxane (PDMS) micronozzle array and bidirectional electrokinetic pumps driven by DC-biased AC voltages. Pt/Ti and indium tin oxide (ITO) electrodes were used to study the effect of DC bias and peak-to-peak voltage and electrodes in a low conductivity isotonic solution. The flow was bidirectionally controlled by changing the DC bias. A pump integrated with a micronozzle array was used to transport single HeLa cells into nozzle holes. The application of DC-biased AC voltage (100 kHz, 10 Vpp, and VDC: -4 V) provided a sufficient electroosmotic flow outside the nozzle array. This integration method of nozzle and pumps is anticipated to be a standard integration method. The operating conditions of DC-biased AC electrokinetic pumps in a biological buffer was clarified and found useful for cell manipulation.
Collapse
Affiliation(s)
- Moeto Nagai
- Department of Mechanical Engineering, Toyohashi University of Technology, Toyohashi, Aichi 441-8580, Japan; (K.K.); (S.S.); (T.S.)
- Correspondence: ; Tel.: +81-532-44-6701
| | - Keita Kato
- Department of Mechanical Engineering, Toyohashi University of Technology, Toyohashi, Aichi 441-8580, Japan; (K.K.); (S.S.); (T.S.)
| | - Satoshi Soga
- Department of Mechanical Engineering, Toyohashi University of Technology, Toyohashi, Aichi 441-8580, Japan; (K.K.); (S.S.); (T.S.)
| | - Tuhin Subhra Santra
- Department of Engineering Design, Indian Institute of Technology Madras, Tamil Nadu 600036, India;
| | - Takayuki Shibata
- Department of Mechanical Engineering, Toyohashi University of Technology, Toyohashi, Aichi 441-8580, Japan; (K.K.); (S.S.); (T.S.)
| |
Collapse
|
19
|
Opalski AS, Ruszczak A, Promovych Y, Horka M, Derzsi L, Garstecki P. Combinatorial Antimicrobial Susceptibility Testing Enabled by Non-Contact Printing. MICROMACHINES 2020; 11:mi11020142. [PMID: 32012854 PMCID: PMC7074582 DOI: 10.3390/mi11020142] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/22/2020] [Accepted: 01/23/2020] [Indexed: 12/21/2022]
Abstract
We demonstrate the utility of non-contact printing to fabricate the mAST—an easy-to-operate, microwell-based microfluidic device for combinatorial antibiotic susceptibility testing (AST) in a point-of-care format. The wells are prefilled with antibiotics in any desired concentration and combination by non-contact printing (spotting). For the execution of the AST, the only requirements are the mAST device, the sample, and the incubation chamber. Bacteria proliferation can be continuously monitored by using an absorbance reader. We investigate the profile of resistance of two reference Escherichia coli strains, report the minimum inhibitory concentration (MIC) for single antibiotics, and assess drug–drug interactions in cocktails by using the Bliss independence model.
Collapse
Affiliation(s)
| | | | | | | | - Ladislav Derzsi
- Correspondence: (L.D.); (P.G.); Tel.: +48-(22)-343-22-33 (L.D. & P.G.)
| | - Piotr Garstecki
- Correspondence: (L.D.); (P.G.); Tel.: +48-(22)-343-22-33 (L.D. & P.G.)
| |
Collapse
|
20
|
Dang BV, Hassanzadeh-Barforoushi A, Syed MS, Yang D, Kim SJ, Taylor RA, Liu GJ, Liu G, Barber T. Microfluidic Actuation via 3D-Printed Molds toward Multiplex Biosensing of Cell Apoptosis. ACS Sens 2019; 4:2181-2189. [PMID: 31321976 DOI: 10.1021/acssensors.9b01057] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Multiplexed analysis of biochemical analytes such as proteins, enzymes, and immune products using a microfluidic device has the potential to cut assay time, reduce sample volume, realize high-throughput, and decrease experimental error without compromising sensitivity. Despite these huge benefits, the need for expensive specialized equipment and the complex photolithography fabrication process for the multiplexed devices have, to date, prevented widespread adoption of microfluidic systems. Here, we present a simple method to fabricate a new microfluidic-based multiplexed biosensing device by taking advantage of 3D-printing. The device is an integration of normally closed (NC) microfluidic valving units which offer superior operational flexibility by using PDMS membrane (E ∼ 1-2 MPa) and require minimized energy input (1-5 kPa). To systematically engineer the device, we first report on the geometrical and operational analysis of a single 3D-printed valving unit. Based on the characterization, we introduce a full prototype multiplexed chip comprising several microfluidic valves. The prototype offers-for the first time in a 3D-printed microfluidic device-the capability of on-demand performce of both a sequential and a parallel biochemical assay. As a proof of concept, our device has been used to simultaneously measure the apoptotic activity of 5 different members of the caspase protease enzyme family. In summary, the 3D-printed valving system showcased in this study overcomes traditional bottlenecks of microfabrication, enabling a new class of sophisticated liquid manipulation required in performing multiplexed sensing for biochemical assays.
Collapse
Affiliation(s)
- Bac Van Dang
- School of Mechanical and Manufacturing Engineering, Faculty of Engineering, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Amin Hassanzadeh-Barforoushi
- School of Mechanical and Manufacturing Engineering, Faculty of Engineering, The University of New South Wales, Sydney, New South Wales 2052, Australia
- Cancer Division, Garvan Institute of Medical Research/the Kinghorn Cancer Centre, Sydney, New South Wales 2010, Australia
| | - Maira Shakeel Syed
- School of Mechanical and Manufacturing Engineering, Faculty of Engineering, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Danting Yang
- Graduate School of Biomedical Engineering, ARC Centre of Excellence in Nanoscale BioPhotonics, Australian Centre for NanoMedicine, Faculty of Engineering, The University of New South Wales, Sydney, New South Wales 2052, Australia
- Department of Preventative Medicine, Zhejiang Provincial Key Laboratory of Pathological and Physiological Technology, Medical School of Ningbo University, Ningbo, Zhejiang 315211, China
| | - Sung-Jin Kim
- Department of Mechanical Engineering, Konkuk University, Seoul, 05029, Republic of Korea
| | - Robert A. Taylor
- School of Mechanical and Manufacturing Engineering, Faculty of Engineering, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Guo-Jun Liu
- Australian Nuclear Science and Technology Organisation, New Illawarra Road, Lucas Heights, New South Wales 2234, Australia
- Discipline of Medical Imaging & Radiation Sciences, Faculty of Medicine and Health, Brain and Mind Centre, University of Sydney, 94 Mallett Street, Camperdown, New South Wales 2050, Australia
| | - Guozhen Liu
- Graduate School of Biomedical Engineering, ARC Centre of Excellence in Nanoscale BioPhotonics, Australian Centre for NanoMedicine, Faculty of Engineering, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Tracie Barber
- School of Mechanical and Manufacturing Engineering, Faculty of Engineering, The University of New South Wales, Sydney, New South Wales 2052, Australia
| |
Collapse
|
21
|
Chen P, Chen D, Li S, Ou X, Liu BF. Microfluidics towards single cell resolution protein analysis. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.06.022] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
22
|
Khanfar MF, Abu Eisheh NJ, Al-Ghussain L, Al-Halhouli AT. Lab on a Chip for the Colorimetric Determination of Nitrite in Processed Meat Products in the Jordanian Market. MICROMACHINES 2019; 10:E36. [PMID: 30621098 PMCID: PMC6356477 DOI: 10.3390/mi10010036] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Revised: 12/28/2018] [Accepted: 01/04/2019] [Indexed: 12/21/2022]
Abstract
Nitrite and Nitrate have been used extensively as additives in various meat products to enhance flavor, color, and to preserve the meat from the bacterial growth. High concentrations of nitrite can threat human health since several studies in the literature claim that nitrite is associated with cancer incidences, leukemia, and brain tumors. Therefore, it is vital to measure the nitrite concentrations in processed meat products. In this study, an in-lab miniaturized photometric detection system is fabricated to inspect the nitrite concentration in processed meat products in Jordan. The analytical performance of nitrite detection is evaluated based on three key statistical parameters; linearity, limit of detection, and limit of quantitation. Respectively, for the fabricated system, the three values are found to be equal to 0.995, 1.24 × 10-2 ppm, and 4.12 × 10-2 ppm. Adherence to Beer's law is found over the investigated range from 2.63 ppm to 96.0 ppm. The developed system is utilized for photometric detection of nitrite in processed meat products available in the Jordanian market like pastrami, salami, and corned beef. In all of the analyzed samples, the nitrite content is found to be lower than 150 ppm, which represents the maximum allowable nitrite limit.
Collapse
Affiliation(s)
- Mohammad F Khanfar
- Department of Pharmaceutical and Chemical Engineering, School of Applied Medical Sciences, German Jordanian University, Amman 11180, Jordan.
| | - Nour J Abu Eisheh
- Department of Pharmaceutical and Chemical Engineering, School of Applied Medical Sciences, German Jordanian University, Amman 11180, Jordan.
| | - Loiy Al-Ghussain
- NanoLab, Mechatronice Engineering Department, School of Applied Technical Sciences, German Jordanian University, Amman 11180, Jordan.
| | - Ala'aldeen T Al-Halhouli
- NanoLab, Mechatronice Engineering Department, School of Applied Technical Sciences, German Jordanian University, Amman 11180, Jordan.
| |
Collapse
|