1
|
Liu Y, Raymond JJ, Wu X, Chua PWL, Ling SYH, Chan CC, Chan C, Loh JXY, Song MXY, Ong MYY, Ho P, Mcbee ME, Springs SL, Yu H, Han J. Electrostatic microfiltration (EM) enriches and recovers viable microorganisms at low-abundance in large-volume samples and enhances downstream detection. LAB ON A CHIP 2024; 24:4275-4287. [PMID: 39189168 DOI: 10.1039/d4lc00419a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/28/2024]
Abstract
Rapid and sensitive detection of pathogens in various samples is crucial for disease diagnosis, environmental surveillance, as well as food and water safety monitoring. However, the low abundance of pathogens (<10 CFU) in large volume (1 mL-1 L) samples containing vast backgrounds critically limits the sensitivity of even the most advanced techniques, such as digital PCR. Therefore, there is a critical need for sample preparation that can enrich low-abundance pathogens from complex and large-volume samples. This study develops an efficient electrostatic microfiltration (EM)-based sample preparation technique capable of processing ultra-large-volume (≥500 mL) samples at high throughput (≥10 mL min-1). This approach achieves a significant enrichment (>8000×) of extremely-low-abundance pathogens (down to level of 0.02 CFU mL-1, i.e., 10 CFU in 500 mL). Furthermore, EM-enabled sample preparation facilitates digital amplification techniques sensitively detecting broad pathogens, including bacteria, fungi, and viruses from various samples, in a rapid (≤3 h) sample-to-result workflow. Notably, the operational ease, portability, and compatibility/integrability with various downstream detection platforms highlight its great potential for widespread applications across diverse settings.
Collapse
Affiliation(s)
- Yaoping Liu
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Joshua J Raymond
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Xiaolin Wu
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Patrina Wei Lin Chua
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Sharon Yan Han Ling
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Chia Ching Chan
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Cheryl Chan
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Joanne Xin Yi Loh
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Melody Xing Yen Song
- School of Life Sciences & Chemical Technology, Ngee Ann Polytechnic, 599489, Singapore
| | - Matilda Yu Yan Ong
- School of Life Sciences & Chemical Technology, Ngee Ann Polytechnic, 599489, Singapore
| | - Peiying Ho
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Megan E Mcbee
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
| | - Stacy L Springs
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Center for Biomedical Innovation, Massachusetts Institute of Technology (MIT), MA 02139, USA
| | - Hanry Yu
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Institute of Bioengineering and Bioimaging (IBB), A*STAR, 138632, Singapore
- Department of physiology and WisDM and Mechanobiology Institute, National University of Singapore, 119077, Singapore
| | - Jongyoon Han
- AntiMicrobial Resistance (AMR) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART), 138602, Singapore
- Center for Biomedical Innovation, Massachusetts Institute of Technology (MIT), MA 02139, USA
- Department of Electrical Engineering and Computer Science, MIT, Cambridge, MA 02139, USA
- Department of Biological Engineering, MIT, Cambridge, MA 02139, USA.
| |
Collapse
|
2
|
Cai J, Chen B, He M, Yuan G, Hu B. An Integrated Inertial-Magnetophoresis Microfluidic Chip Online-Coupled with ICP-MS for Rapid Separation and Precise Detection of Circulating Tumor Cells. Anal Chem 2024; 96:14222-14229. [PMID: 39159467 DOI: 10.1021/acs.analchem.4c02876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/21/2024]
Abstract
Circulating tumor cells (CTCs) are recognized as promising targets for liquid biopsy, which play an important role in early diagnosis and efficacy monitoring of cancer. However, due to the extreme scarcity of CTCs and partial size overlap between CTCs and white blood cells (WBCs), the separation and detection of CTCs from blood remain a big challenge. To address this issue, we fabricated a microfluidic chip by integrating a passive contraction-expansion array (CEA) inertial sorting zone and an active magnetophoresis zone with the trapezoidal groove and online coupled it with inductively coupled plasma mass spectrometry (ICP-MS) for rapid separation and precise detection of MCF-7 cells (as a model CTC) in blood samples. In the integrated microfluidic chip, most of the small-sized WBCs can be rapidly removed in the circular CEA inertial sorter, while the rest of the magnetically labeled WBCs can be further captured in the trapezoidal groove under the magnetic field. As a result, the rapid separation of MCF-7 cells from blood samples was achieved with an average recovery of 91.6% at a sample flow rate of 200 μL min-1. The developed online integrated inertial-magnetophoresis microfluidic chip-ICP-MS system has been applied for the detection of CTCs in real clinical blood samples with a fast analysis speed (5 min per 1 mL blood). CTCs were detected in all 24 blood samples from patients with different types of cancer, exhibiting excellent application potential in clinical diagnosis.
Collapse
Affiliation(s)
- Jing Cai
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Beibei Chen
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Man He
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Guolin Yuan
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| | - Bin Hu
- Department of Chemistry, Wuhan University, Wuhan 430072, China
| |
Collapse
|
3
|
Rabadi I, Carpentieri D, Wang J, Zenhausern F, Gu J. On reactive Ion Etching of Parylene-C with Simple Photoresist Mask for Fabrication of High Porosity Membranes to Capture Circulating and Exfoliated Tumor Cells. MICROMACHINES 2024; 15:521. [PMID: 38675332 PMCID: PMC11051955 DOI: 10.3390/mi15040521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 04/09/2024] [Accepted: 04/09/2024] [Indexed: 04/28/2024]
Abstract
A high porosity micropore arrayed parylene membrane is a promising device that is used to capture circulating and exfoliated tumor cells (CTCs and ETCs) for liquid biopsy applications. However, its fabrication still requires either expensive equipment or an expensive process. Here, we report on the fabrication of high porosity (>40%) micropore arrayed parylene membranes through a simple reactive ion etching (RIE) that uses photoresist as the etching mask. Vertical sidewalls were observed in etched parylene pores despite the sloped photoresist mask sidewalls, which was found to be due to the simultaneous high DC-bias RIE induced photoresist melting and substrate pedestal formation. A theoretical model has been derived to illustrate the dependence of the maximum membrane thickness on the final pore-to-pore spacing, and it is consistent with the experimental data. A simple, yet accurate, low number (<50) cell counting method was demonstrated through counting cells directly inside a pipette tip under phase-contrast microscope. Membranes as thin as 3 μm showed utility for low number tumor cell capture, with an efficiency of 87-92%.
Collapse
Affiliation(s)
- Inad Rabadi
- Center for Applied NanoBioscience and Medicine, The University of Arizona College of Medicine, Phoenix, AZ 85004, USA; (I.R.); (F.Z.)
- Department of Basic Medical Sciences, The University of Arizona College of Medicine, Phoenix, AZ 85004, USA
| | | | - Jue Wang
- Dignity Health-Cancer Institute at St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85004, USA;
| | - Frederic Zenhausern
- Center for Applied NanoBioscience and Medicine, The University of Arizona College of Medicine, Phoenix, AZ 85004, USA; (I.R.); (F.Z.)
- Department of Basic Medical Sciences, The University of Arizona College of Medicine, Phoenix, AZ 85004, USA
- Honor Health Research Institute, Scottsdale, AZ 85258, USA
| | - Jian Gu
- Center for Applied NanoBioscience and Medicine, The University of Arizona College of Medicine, Phoenix, AZ 85004, USA; (I.R.); (F.Z.)
- Department of Basic Medical Sciences, The University of Arizona College of Medicine, Phoenix, AZ 85004, USA
| |
Collapse
|
4
|
Jia P, Zhou S, Cai X, Guo Q, Niu H, Ning W, Sun Y, Zhang D. High-fidelity synthesis of microhole templates with low-surface-energy-enabled self-releasing photolithography. RSC Adv 2024; 14:12125-12130. [PMID: 38628485 PMCID: PMC11019348 DOI: 10.1039/d4ra00660g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 03/29/2024] [Indexed: 04/19/2024] Open
Abstract
Material patterning through templates has provided an efficient way to meet the critical requirement for surface function in various fields. Here, we develop a self-releasing photolithographic process to make large-area freestanding templates with precise patterns. The low surface energy of substrates by hydrophobic treatment with proper silane modification ensures the template self-releasing. This method eliminates the need of mechanical separation or any sacrificial layers. Major steps including UV exposure and baking are optimized to realize high-quality structures and the final release of templates. The negative photoresists of SU-8 and polyimide are chosen to confirm the feasibility of this process. Wafer-scale freestanding templates with uniform microhole arrays are obtained with high structural fidelity, smooth surfaces and excellent flexibility. The hole size ranges from several to several tens of micrometers with an extremely low variation (<1%). These advantages could promote the application of precisely structured templates for surface patterning in material and surface science.
Collapse
Affiliation(s)
- Peipei Jia
- Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China Shenzhen Guangdong 518100 China
| | - Shaolin Zhou
- School of Electronics and Information Engineering, South China University of Technology Guangzhou Guangdong China
| | - Xiaobing Cai
- School of Aerospace Engineering, Xi'an Jiaotong University Xi'an Shanxi China
| | - Qiuquan Guo
- Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China Shenzhen Guangdong 518100 China
| | - Haoran Niu
- Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China Shenzhen Guangdong 518100 China
| | - Wenping Ning
- Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China Shenzhen Guangdong 518100 China
| | - Yong Sun
- Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China Shenzhen Guangdong 518100 China
| | - Dongxing Zhang
- Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China Shenzhen Guangdong 518100 China
| |
Collapse
|
5
|
Lv W, Fu B, Liu W, Huang W, Li M, Liu Y, Kang Y, Wang J, Bai S, Lu C, Dai X. Efficient detection of single circulating tumor cell in blood using Raman mapping based on Aptamer-SERS bio-probe coupled with micropore membrane filtration. Talanta 2024; 267:125220. [PMID: 37783108 DOI: 10.1016/j.talanta.2023.125220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 08/15/2023] [Accepted: 09/16/2023] [Indexed: 10/04/2023]
Abstract
Rapid and accurate detection of rare circulating tumor cells (CTCs) in human blood still remains a challenge. We present a surface enhanced Raman spectroscopy (SERS) method based on aptamer-SERS bio-probe recognition coupled with micropore membrane filtration capture for the detection of CTCs at single cell level. The parylene micropore membrane with optimized micropore size installed on a filtration holder could capture bio-probe labeled CTCs by gravity in less than 10 s, and only with very less white blood cells (WBCs) residual. In order to facilitate the synthesis of the aptamer-SERS bio-probe, ethyl acetate dehydration method was established. The bio-probe can be rapidly synthesized within 2 h by binding SH-aptamer to 4- mercaptobenzoic acid (4-MBA) modified AuNPs with the help of ethyl acetate. The SERS bio-probe with selected specific aptamer could distinguish single human non-small cell lung cancer A549 cells from residual WBCs on membrane efficiently and reliably based on their Raman signal intensity difference at 1075 cm-1. Through the filter membrane coupled with aptamer-SERS bio-probe system, even 20 A549 cells in blood solution simulating CTCs sample can be detected, which the recovery rate and recognition rate are more than 90%. This method is rapid, reliable and cost-effective, which indicates a good prospect in clinical application for CTCs detection.
Collapse
Affiliation(s)
- Wanxue Lv
- State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029, China; National Institute of Metrology China, Beijing, 100029, China
| | - Boqiang Fu
- National Institute of Metrology China, Beijing, 100029, China.
| | - Wencheng Liu
- National Institute of Metrology China, Beijing, 100029, China
| | - Wenfeng Huang
- National Institute of Metrology China, Beijing, 100029, China
| | - Manli Li
- National Institute of Metrology China, Beijing, 100029, China
| | - Yingying Liu
- National Institute of Metrology China, Beijing, 100029, China
| | - Yu Kang
- State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Jing Wang
- National Institute of Metrology China, Beijing, 100029, China
| | - Shouli Bai
- State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Chao Lu
- State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029, China.
| | - Xinhua Dai
- National Institute of Metrology China, Beijing, 100029, China.
| |
Collapse
|
6
|
Lu H, Lin D. Diagnostic value of exfoliated tumor cells combined with DNA methylation in bronchoalveolar lavage fluid for lung cancer. Medicine (Baltimore) 2023; 102:e34955. [PMID: 37682182 PMCID: PMC10489317 DOI: 10.1097/md.0000000000034955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 08/04/2023] [Indexed: 09/09/2023] Open
Abstract
BACKGROUND To evaluate the diagnostic value of exfoliated tumor cells (ETCs) numbers combined with DNA methylation levels in bronchoalveolar lavage fluid (BALF) in lung cancer. METHODS BALF samples were collected from 43 patients with lung cancer and 23 with benign lung disease. ETCs were detected by the nano-enrichment method, and the methylation status of the short stature homeobox gene 2 (SHOX2) and the RAS association domain family 1, isoform A (RASSF1A) gene were detected by RT-PCR. The diagnostic value of each metric was evaluated by receiver operating characteristic curve analysis, specificity and sensitivity. RESULTS The sensitivity/specificity of RASSF1A and SHOX2 methylation detection were 44.12%/76.47% and 93.75%/87.50%, respectively. When "RASSF1A/SHOX2 methylation" was used as a positive result, the sensitivity increased to 88.24%, and the specificity decreased to 81.25%. When "RASSF1A + SHOX methylation" was used as positive, the sensitivity was reduced to 32.35%, but the specificity was increased to 100.00%. The sensitivity and specificity of ETCs detection in BALF were 89.47% and 16.67%, respectively. When "SHOX2/RASSF1A methylation + ETCs was used as a positive result, the sensitivity and specificity of the detection were 79.31% and 81.82%, respectively. When "SHOX2 + RASSF1A + ETCs" was used as positive, the sensitivity was 34.48% and the specificity was 90.91%. Receiver operating characteristic curve analysis showed that when SHOX2, RASSF1A methylation and ETCs were combined, the diagnostic sensitivity increased to 0.778. CONCLUSION ETCs counting in combination with SHOX2 and RASSF1A methylation assays in BALF samples has demonstrated excellent sensitivity for lung cancer diagnosis and is an effective complementary tool for clinical diagnosis of lung cancer.
Collapse
Affiliation(s)
- Huiling Lu
- Department of Pulmonary and Critical Care Medicine, Affiliated Suzhou Municipal Hospital of Nanjing Medical University, Jiangsu, China
| | - Dang Lin
- Department of Pulmonary and Critical Care Medicine, Affiliated Suzhou Municipal Hospital of Nanjing Medical University, Jiangsu, China
| |
Collapse
|
7
|
Lab-on-a-chip systems for cancer biomarker diagnosis. J Pharm Biomed Anal 2023; 226:115266. [PMID: 36706542 DOI: 10.1016/j.jpba.2023.115266] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 01/20/2023] [Accepted: 01/20/2023] [Indexed: 01/22/2023]
Abstract
Lab-on-a-chip (LOC) or micro total analysis system is one of the microfluidic technologies defined as the adaptation, miniaturization, integration, and automation of analytical laboratory procedures into a single instrument or "chip". In this article, we review developments over the past five years in the application of LOC biosensors for the detection of different types of cancer. Microfluidics encompasses chemistry and biotechnology skills and has revolutionized healthcare diagnosis. Superior to traditional cell culture or animal models, microfluidic technology has made it possible to reconstruct functional units of organs on chips to study human diseases such as cancer. LOCs have found numerous biomedical applications over the past five years, including integrated bioassays, cell analysis, metabolomics, drug discovery and delivery systems, tissue and organ physiology and disease modeling, and personalized medicine. This review provides an overview of the latest developments in microfluidic-based cancer research, with pros, cons, and prospects.
Collapse
|
8
|
Xue S, Xu Q, Xu Z, Zhang X, Zhang H, Zhang X, He F, Chen Y, Xue Y, Hao P. Manipulation of Particle/Cell Based on Compressibility in a Divergent Microchannel by Surface Acoustic Wave. Anal Chem 2023; 95:4282-4290. [PMID: 36815437 DOI: 10.1021/acs.analchem.2c03841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
The mechanical properties (compressibility or deformability) of cells are closely related to their death, migration, and differentiation. Accurate separation and manipulation of bioparticles based on these mechanical properties are still a challenging in the field of acoustofluidics. In this work, based on surface acoustic waves (SAW) and divergent microchannels, we developed a new method for separating and detecting particles or cells with different compressibility. The difference in acoustic radiation force (Fr) caused by compressibility are gradually amplified and accumulated by decreasing the flow velocity, and they are finally reflected in the particle migration distance. During the transverse migration process, the alternating dominance of the acoustic radiation force and the Stokes resistance force (Fs) drives the particles to create three typical migration patterns: intermittent migration, compound migration, and near-wall migration. In the present tilted SAW device, a 91% separation success rate of ∼10 μm polystyrene (PS) and polydimethylsiloxane (PDMS) particles can be achieved by optimizing the acoustic field input power and the fluid velocity. The application potential of the present divergent microchannel is validated by separating the myelogenous leukemia cell K562 and the natural killer cell NK92 that have similar densities and sizes (∼15 μm) but different compressibility. The results of this work are expected to provide valuable insights into the acoustofluidics separation and detection of the cells that are with different compressibility.
Collapse
Affiliation(s)
- Sen Xue
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Qingmei Xu
- School of Integrated Circuits, Peking University, Beijing 100871, China
| | - Zhike Xu
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Xuanhe Zhang
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Haixiang Zhang
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Xiwen Zhang
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Feng He
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Yiqing Chen
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Yu Xue
- School of Medicine & Holistic Integrative Medicine, Nanjing University of Chinese Medicine, Nanjing 210023, China
| | - Pengfei Hao
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
9
|
Cheng Y, Zhang S, Qin L, Zhao J, Song H, Yuan Y, Sun J, Tian F, Liu C. Poly(ethylene oxide) Concentration Gradient-Based Microfluidic Isolation of Circulating Tumor Cells. Anal Chem 2023; 95:3468-3475. [PMID: 36725367 DOI: 10.1021/acs.analchem.2c05257] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Circulating tumor cells (CTCs) have emerged as promising circulating biomarkers for non-invasive cancer diagnosis and management. Isolation and detection of CTCs in clinical samples are challenging due to the extreme rarity and high heterogeneity of CTCs. Here, we describe a poly(ethylene oxide) (PEO) concentration gradient-based microfluidic method for rapid, label-free, highly efficient isolation of CTCs directly from whole blood samples. Stable concentration gradients of PEO were formed within the microchannel by co-injecting the side fluid (blood sample spiked with 0.025% PEO) and center fluid (0.075% PEO solution). The competition between the elastic lift force and the inertial lift force enabled size-based separation of large CTCs and small blood cells based on their distinct migration patterns. The microfluidic device could process 1 mL of blood sample in 30 min, with a separation efficiency of >90% and an enrichment ratio of >700 for tumor cells. The isolated CTCs from blood samples were enumerated by immunofluorescence staining, allowing for discrimination of breast cancer patients from healthy donors with an accuracy of 84.2%. The concentration gradient-based microfluidic separation provides a powerful tool for label-free isolation of CTCs for a wide range of clinical applications.
Collapse
Affiliation(s)
- Yangchang Cheng
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Shaohua Zhang
- Department of Oncology, Senior Department of Oncology, The Fifth Medical Center of PLA General Hospital, Beijing 100071, China
| | - Lili Qin
- Department of Oncology, Senior Department of Oncology, The Fifth Medical Center of PLA General Hospital, Beijing 100071, China
| | - Junxiang Zhao
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hua Song
- Department of Oncology, Senior Department of Oncology, The Fifth Medical Center of PLA General Hospital, Beijing 100071, China
| | - Yang Yuan
- Department of Oncology, Senior Department of Oncology, The Fifth Medical Center of PLA General Hospital, Beijing 100071, China
| | - Jiashu Sun
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fei Tian
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Chao Liu
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, National Center for Nanoscience and Technology, Beijing 100190, China.,School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
10
|
Li A, He X, Wu J, Zhang J, Xu G, Xu B, Zhao G, Shen Z. Ultrathin silicon nitride membrane with slit-shaped pores for high-performance separation of circulating tumor cells. LAB ON A CHIP 2022; 22:3676-3686. [PMID: 35997043 DOI: 10.1039/d2lc00703g] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In this study, we developed an ultrathin filtering membrane with slit-shaped pores which can achieve circulating tumor cell (CTC) separation from whole blood with high performance (high capture efficiency, high white blood cell (WBC) depletion, and high viability). The silicon nitride (Si3N4) filtering membrane was fabricated via the standard microfabrication technology, which can be easily scaled up to mass-production. 6 μm was determined as the optimum width of the filtering pores to better separate CTCs in whole blood, which can reach a high capture efficiency of ∼96%. Meanwhile, the filtering membrane with a high porosity of 34% demonstrated high WBC depletion (∼99.99%). Furthermore, the ultrathin (thickness: 200 nm) Si3N4 membrane facilitated the capture of CTCs with high viability (∼90%). Finally, the microfluidic chip was successfully applied to separate CTCs in whole blood samples from cancer patients and used for molecular examination. These results indicate that this microfluidic chip facilitates the clinical application of CTC-based liquid biopsy technology.
Collapse
Affiliation(s)
- Ang Li
- Department of Clinical Laboratory, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China.
| | - Xiaodong He
- Department of Clinical Laboratory, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China.
| | - Jing Wu
- Department of Clinical Laboratory, Anhui Provincial Hospital Affiliated to Anhui Medical University, Hefei, Anhui, 230001, China
| | - Juan Zhang
- Department of Clinical Laboratory, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China.
| | - Guoyong Xu
- School of Engineering Science, University of Science and Technology of China, Hefei, Anhui, 230026, China.
| | - Bing Xu
- School of Mechanical Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China.
| | - Gang Zhao
- School of Engineering Science, University of Science and Technology of China, Hefei, Anhui, 230026, China.
| | - Zuojun Shen
- Department of Clinical Laboratory, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China.
- Department of Clinical Laboratory, Anhui Provincial Hospital Affiliated to Anhui Medical University, Hefei, Anhui, 230001, China
| |
Collapse
|
11
|
In Situ Electroporation on PERFECT Filter for High-Efficiency and High-Viability Tumor Cell Labeling. MICROMACHINES 2022; 13:mi13050672. [PMID: 35630139 PMCID: PMC9146625 DOI: 10.3390/mi13050672] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 04/20/2022] [Accepted: 04/20/2022] [Indexed: 02/05/2023]
Abstract
Labeling-assisted visualization is a powerful strategy to track circulating tumor cells (CTCs) for mechanism study (e.g., tumor metastasis). Due to the rarity of CTCs in the whole blood, efficient simultaneous enrichment and labeling of CTCs are needed. Hereby, novel in situ electroporation on a previously-developed micropore-arrayed filter (PERFECT filter) is proposed. Benefiting from the ultra-small-thickness and high-porosity of the filter plus high precision pore diameter, target rare tumor cells were enriched with less damage and uniform size distribution, contributing to enhanced molecular delivery efficiency and cell viability in the downstream electroporation. Various biomolecules (e.g., small molecule dyes, plasmids, and functional proteins) were used to verify this in situ electroporation system. High labeling efficiency (74.08 ± 2.94%) and high viability (81.15 ± 3.04%, verified via live/dead staining) were achieved by optimizing the parameters of electric field strength and pulse number, ensuring the labeled tumor cells can be used for further culture and down-stream analysis. In addition, high specificity (99.03 ± 1.67%) probing of tumor cells was further achieved by introducing fluorescent dye-conjugated antibodies into target cells. The whole procedure, including cell separation and electroporation, can be finished quickly (<10 min). The proposed in situ electroporation on the PERFECT filter system has great potential to track CTCs for tumor metastasis studies.
Collapse
|
12
|
Chen T, Huang C, Wang Y, Wu J. Microfluidic methods for cell separation and subsequent analysis. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.07.067] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
13
|
Descamps L, Le Roy D, Deman AL. Microfluidic-Based Technologies for CTC Isolation: A Review of 10 Years of Intense Efforts towards Liquid Biopsy. Int J Mol Sci 2022; 23:ijms23041981. [PMID: 35216097 PMCID: PMC8875744 DOI: 10.3390/ijms23041981] [Citation(s) in RCA: 37] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/04/2022] [Accepted: 02/07/2022] [Indexed: 02/01/2023] Open
Abstract
The selection of circulating tumor cells (CTCs) directly from blood as a real-time liquid biopsy has received increasing attention over the past ten years, and further analysis of these cells may greatly aid in both research and clinical applications. CTC analysis could advance understandings of metastatic cascade, tumor evolution, and patient heterogeneity, as well as drug resistance. Until now, the rarity and heterogeneity of CTCs have been technical challenges to their wider use in clinical studies, but microfluidic-based isolation technologies have emerged as promising tools to address these limitations. This review provides a detailed overview of latest and leading microfluidic devices implemented for CTC isolation. In particular, this study details must-have device performances and highlights the tradeoff between recovery and purity. Finally, the review gives a report of CTC potential clinical applications that can be conducted after CTC isolation. Widespread microfluidic devices, which aim to support liquid-biopsy-based applications, will represent a paradigm shift for cancer clinical care in the near future.
Collapse
Affiliation(s)
- Lucie Descamps
- Univ Lyon, Université Claude Bernard Lyon 1, CNRS, INSA Lyon, Ecole Centrale de Lyon, CPE Lyon, INL, UMR5270, 69622 Villeurbanne, France;
| | - Damien Le Roy
- Institut Lumière Matière ILM-UMR 5306, CNRS, Université Lyon 1, 69622 Villeurbanne, France;
| | - Anne-Laure Deman
- Univ Lyon, Université Claude Bernard Lyon 1, CNRS, INSA Lyon, Ecole Centrale de Lyon, CPE Lyon, INL, UMR5270, 69622 Villeurbanne, France;
- Correspondence:
| |
Collapse
|
14
|
Multi-Modal Microfluidics (M3) for Sample Preparation of Liquid Biopsy: Bridging the Gap between Proof-of-Concept Demonstrations and Practical Applications. MICROMACHINES 2022; 13:mi13020209. [PMID: 35208333 PMCID: PMC8874502 DOI: 10.3390/mi13020209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 01/23/2022] [Accepted: 01/26/2022] [Indexed: 02/01/2023]
Abstract
Liquid biopsy, the technique used to shed light on diseases via liquid samples, has displayed various advantages, including minimal invasiveness, low risk, and ease of multiple sampling for dynamic monitoring, and has drawn extensive attention from multidisciplinary fields in the past decade. With the rapid development of microfluidics, it has been possible to manipulate targets of interest including cells, microorganisms, and exosomes at a single number level, which dramatically promotes the characterization and analysis of disease-related markers, and thus improves the capability of liquid biopsy. However, when lab-ready techniques transfer into hospital-applicable tools, they still face a big challenge in processing raw clinical specimens, which are usually of a large volume and consist of rare targets drowned in complex backgrounds. Efforts toward the sample preparation of clinical specimens (i.e., recovering/concentrating the rare targets among complex backgrounds from large-volume liquids) are required to bridge the gap between the proof-of-concept demonstrations and practical applications. The throughput, sensitivity, and purity (TSP performance criteria) in sample preparation, i.e., the volume speed in processing liquid samples and the efficiencies of recovering rare targets and depleting the backgrounds, are three key factors requiring careful consideration when implementing microfluidic-based liquid biopsy for clinical practices. Platforms based on a single microfluidic module (single-modal microfluidics) can hardly fulfill all the aforementioned TSP performance criteria in clinical practices, which puts forward an urgent need to combine/couple multiple microfluidic modules into one working system (i.e., multi-modal microfluidics, M3) to realize practically applicable techniques for the sample preparation of liquid biopsy. This perspective briefly summarizes the typical microfluidic-based liquid biopsy techniques and discusses potential strategies to develop M3 systems for clinical practices of liquid biopsy from the aspect of sample preparation.
Collapse
|
15
|
Zhao K, Liu Y, Wang H, Song Y, Chen X, Huang C, Niu Q, Cao J, Chen X, Wang W, Wu L, Yang C. Selective, user-friendly, highly porous, efficient, and rapid (SUPER) filter for isolation and analysis of rare tumor cells. LAB ON A CHIP 2022; 22:367-376. [PMID: 34918732 DOI: 10.1039/d1lc00886b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Rapid, efficient, and selective separation of tumor cells from complex body fluids is urgently needed for clinical application of tumor-cell-based liquid biopsy. Herein, a size-selective affinity filtration system, named selective, user-friendly, highly porous, efficient, and rapid filter (SUPER Filter), was developed for high-performance tumor cell isolation and analysis. SUPER Filter enabled selective interaction of tumor cells with size-optimized and antibody-coated micropore walls during filtration, achieving a high efficiency of 91.0 ± 6.1% in buffer and 83.7 ± 6.4% in whole blood. Meanwhile, its larger micropore size than those of traditional filtration devices greatly reduced the nonspecific capture of background cells (55-126 cells per mL blood) with enrichment factors of 1.1 × 104-1.0 × 105 and a purity of 52.7 ± 4.2%. Moreover, its high porosity enabled ultra-fast (<5 s for 1 mL of blood or 10 mL of buffer samples) and user-friendly gravity-driven filtration. Finally, SUPER Filter demonstrated rapid, efficient, and selective separation of tumor cells from blood and large-volume pleural and ascetic fluid samples from cancer patients for morphological and molecular analysis. We expect that this size-selective affinity filtration strategy facilitates the clinical application of tumor-cell-based liquid biopsy.
Collapse
Affiliation(s)
- Kaifeng Zhao
- Institute of Molecular Medicine, Clinical Laboratory, Department of Gastrointestinal Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Yaoping Liu
- Institute of Microelectronics, Peking University, Beijing, 100871, China.
| | - Hua Wang
- Institute of Molecular Medicine, Clinical Laboratory, Department of Gastrointestinal Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
| | - Yanling Song
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Xiaofeng Chen
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Chen Huang
- Institute of Molecular Medicine, Clinical Laboratory, Department of Gastrointestinal Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
| | - Qi Niu
- Institute of Molecular Medicine, Clinical Laboratory, Department of Gastrointestinal Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
| | - Jiao Cao
- Institute of Molecular Medicine, Clinical Laboratory, Department of Gastrointestinal Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
| | - Xin Chen
- Institute of Molecular Medicine, Clinical Laboratory, Department of Gastrointestinal Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
| | - Wei Wang
- Institute of Microelectronics, Peking University, Beijing, 100871, China.
| | - Lingling Wu
- Institute of Molecular Medicine, Clinical Laboratory, Department of Gastrointestinal Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
| | - Chaoyong Yang
- Institute of Molecular Medicine, Clinical Laboratory, Department of Gastrointestinal Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
- The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, The Key Laboratory of Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemical Biology, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| |
Collapse
|
16
|
Cheng J, Zhang L, Zhang Y, Ye Y, Zhao W, Zhang L, Li Y, Liu Y, Zhang W, Guo H, Li M, Zhao Y, Huang C. 3D spiral channels combined with flexible micro-sieve for high-throughput rare tumor cell enrichment and assay from clinical pleural effusion samples. Biodes Manuf 2022. [DOI: 10.1007/s42242-021-00167-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
17
|
Li D, Wang C, Ni Y, Liu Y, Wang W, Zhang S, Chang HC, Senapati S. Development of a Multi-target Protein Biomarker Assay for Circulating Tumor Cells. Methods Mol Biol 2022; 2394:3-18. [PMID: 35094318 DOI: 10.1007/978-1-0716-1811-0_1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
We report a highly sensitive and selective CNT-switch liquid biopsy platform that detects and quantifies protein biomarker expressions from circulating tumor cells in blood for early detection of metastatic breast cancer and its relapse. This platform first isolates and enriches more than 99% of tumor cells with an off-chip micro-size membrane filtration technique and then conducts on-chip detection of the membrane and internal protein biomarkers of the tumor cells with high sensitivity and selectivity. High sensitivity is achieved with complete association of the antibody-antigen-antibody (Ab-Ag-Ab) complex by precisely and rapidly assembling carbon nanotubes (CNTs) across two parallel electrodes via sequential DC electrophoresis and dielectrophoresis (DEP) deposition. Each bridged CNT acts as a switch that connects the electrodes and closes the circuit to generate an electrical signal. The high selectivity is achieved with a critical hydrodynamic shear rate that irreversibly removes non-target linkers of the aligned CNTs. At present, we are able to detect the protein biomarkers from 5 spiked breast cancer tumor cells of different types within 7.5 ml of human blood samples. This demonstrates the potential of this platform as an inexpensive and noninvasive alternative to MRI scans and tissue biopsies currently used to detect early metastatic breast cancer and its relapse.
Collapse
Affiliation(s)
- Diya Li
- Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, USA
| | - Ceming Wang
- Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, USA
| | - Yingjia Ni
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, USA
| | - Yaoping Liu
- Institute of Microelectronics, Peking University, Beijing, China
| | - Wei Wang
- Institute of Microelectronics, Peking University, Beijing, China
- National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Beijing, China
| | - Siyuan Zhang
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, USA
- Harper Cancer Research Institute, University of Notre Dame, Notre Dame, IN, USA
| | - Hsueh-Chia Chang
- Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, USA
- Harper Cancer Research Institute, University of Notre Dame, Notre Dame, IN, USA
| | - Satyajyoti Senapati
- Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, USA.
| |
Collapse
|
18
|
Real-Time Detection of Tumor Cells during Capture on a Filter Element Significantly Enhancing Detection Rate. BIOSENSORS-BASEL 2021; 11:bios11090312. [PMID: 34562902 PMCID: PMC8472380 DOI: 10.3390/bios11090312] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 08/23/2021] [Accepted: 08/29/2021] [Indexed: 12/21/2022]
Abstract
Circulating tumor cells (CTCs) that enter the bloodstream play an important role in the formation of metastases. The prognostic significance of CTCs as biomarkers obtained from liquid biopsies is intensively investigated and requires accurate methods for quantification. The purpose of this study was the capture of CTCs on an optically accessible surface for real-time quantification. A filtration device was fabricated from a transparent material so that capturing of cells could be observed microscopically. Blood samples were spiked with stained tumor cells and the sample was filtrated using a porous structure with pore sizes of 7.4 µm. The possible removal of lysed erythrocytes and the retention of CTCs were assessed. The filtration process was observed in real-time using fluorescence microscopy, whereby arriving cells were counted in order to determine the number of CTCs present in the blood. Through optimization of the microfluidic channel design, the cell retention rate could be increased by 13% (from 76% ± 7% to 89% ± 5%). Providing the possibility for real-time detection significantly improved quantification efficiency even for the smallest cells evaluated. While end-point evaluation resulted in a detection rate of 63% ± 3% of the spiked cells, real-time evaluation led to an increase of 21% to 84% ± 4%. The established protocol provides an advantageous and efficient method for integration of fully automated sample preparation and CTC quantification into a lab-on-a-chip system.
Collapse
|
19
|
Park C, Abafogi AT, Ponnuvelu DV, Song I, Ko K, Park S. Enhanced Luminescent Detection of Circulating Tumor Cells by a 3D Printed Immunomagnetic Concentrator. BIOSENSORS 2021; 11:278. [PMID: 34436080 PMCID: PMC8391490 DOI: 10.3390/bios11080278] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 08/09/2021] [Accepted: 08/16/2021] [Indexed: 12/16/2022]
Abstract
Circulating tumor cells (CTCs) are an indicator of metastatic progression and relapse. Since non-CTC cells such as red blood cells outnumber CTCs in the blood, the separation and enrichment of CTCs is key to improving their detection sensitivity. The ATP luminescence assay can measure intracellular ATP to detect cells quickly but has not yet been used for CTC detection in the blood because extracellular ATP in the blood, derived from non-CTCs, interferes with the measurement. Herein, we report on the improvement of the ATP luminescence assay for the detection of CTCs by separating and concentrating CTCs in the blood using a 3D printed immunomagnetic concentrator (3DPIC). Because of its high-aspect-ratio structure and resistance to high flow rates, 3DPIC allows cancer cells in 10 mL to be concentrated 100 times within minutes. This enables the ATP luminescence assay to detect as low as 10 cells in blood, thereby being about 10 times more sensitive than when commercial kits are used for CTC concentration. This is the first time that the ATP luminescence assay was used for the detection of cancer cells in blood. These results demonstrate the feasibility of 3DPIC as a concentrator to improve the detection limit of the ATP luminescence assay for the detection of CTCs.
Collapse
Affiliation(s)
- Chanyong Park
- Department of Medical Device, Korea Institute of Machinery & Materials (KIMM), Daegu 42994, Korea;
| | - Abdurhaman Teyib Abafogi
- School of Mechanical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea; (A.T.A.); (D.V.P.)
| | - Dinesh Veeran Ponnuvelu
- School of Mechanical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea; (A.T.A.); (D.V.P.)
| | - Ilchan Song
- Department of Medicine, College of Medicine, Chung-Ang University, Seoul 06974, Korea; (I.S.); (K.K.)
| | - Kisung Ko
- Department of Medicine, College of Medicine, Chung-Ang University, Seoul 06974, Korea; (I.S.); (K.K.)
| | - Sungsu Park
- School of Mechanical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea; (A.T.A.); (D.V.P.)
- Department of Biomedical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea
- Institute of Quantum Biophysics (IQB), Sungkyunkwan University (SKKU), Suwon 16419, Korea
| |
Collapse
|
20
|
Hyler AR, Hong D, Davalos RV, Swami NS, Schmelz EM. A novel ultralow conductivity electromanipulation buffer improves cell viability and enhances dielectrophoretic consistency. Electrophoresis 2021; 42:1366-1377. [PMID: 33687759 DOI: 10.1002/elps.202000324] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 01/23/2021] [Accepted: 02/27/2021] [Indexed: 12/21/2022]
Abstract
Cell separation has become a critical diagnostic, research, and treatment tool for personalized medicine. Despite significant advances in cell separation, most widely used applications require the use of multiple, expensive antibodies to known markers in order to identify subpopulations of cells for separation. Dielectrophoresis (DEP) provides a biophysical separation technique that can target cell subpopulations based on phenotype without labels and return native cells for downstream analysis. One challenge in employing any DEP device is the sample being separated must be transferred into an ultralow conductivity medium, which can be detrimental in retaining cells' native phenotypes for separation. Here, we measured properties of traditional DEP reagents and determined that after just 1-2 h of exposure and subsequent culture, cells' viability was significantly reduced below 50%. We developed and tested a novel buffer (Cyto Buffer) that achieved 6 weeks of stable shelf-life and demonstrated significantly improved viability and physiological properties. We then determined the impact of Cyto Buffer on cells' dielectric properties and morphology and found that cells retained properties more similar to that of their native media. Finally, we vetted Cyto Buffer's usability on a cell separation platform (Cyto R1) to determine combined efficacy for cell separations. Here, more than 80% of cells from different cell lines were recovered and were determined to be >70% viable following exposure to Cyto Buffer, flow stimulation, electromanipulation, and downstream collection and growth. The developed buffer demonstrated improved opportunities for electrical cell manipulation, enrichment, and recovery for next generation cell separations.
Collapse
Affiliation(s)
| | - Daly Hong
- CytoRecovery, Inc., Blacksburg, VA, USA
| | - Rafael V Davalos
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, USA
| | - Nathan S Swami
- Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, USA
| | - Eva M Schmelz
- Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, USA.,Human Nutrition, Foods and Exercise, Virginia Tech, Blacksburg, VA, USA
| |
Collapse
|
21
|
Wang L, Dai C, Jiang L, Tong G, Xiong Y, Khan K, Tang Z, Chen X, Zeng H. Advanced Devices for Tumor Diagnosis and Therapy. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2100003. [PMID: 34110694 DOI: 10.1002/smll.202100003] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/01/2021] [Revised: 02/04/2021] [Indexed: 06/12/2023]
Abstract
At present, tumor diagnosis is performed using common procedures, which are slow, costly, and still presenting difficulties in diagnosing tumors at their early stage. Tumor therapeutic methods also mainly rely on large-scale equipment or non-intelligent treatment approaches. Thus, an early and accurate tumor diagnosis and personalized treatment may represent the best treatment option for a successful result, and the efforts in finding them are still in progress and mainly focusing on non-destructive, integrated, and multiple technologies. These objectives can be achieved with the development of advanced devices and smart technology that represent the topic of the current investigations. Therefore, this review summarizes the progress in tumor diagnosis and therapy and briefly explains the advantages and disadvantages of the described microdevices, finally proposing advanced micro smart devices as the future development trend for tumor diagnosis and therapy.
Collapse
Affiliation(s)
- Lude Wang
- Institute of Optoelectronics & Nanomaterials, MIIT Key Laboratory of Advanced Display Materials and Devices, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
- International Collaborative Laboratory of 2D Materials for Optoelectronics Science and Technology of Ministry of Education, Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, 518060, China
| | - Chendong Dai
- Institute of Optoelectronics & Nanomaterials, MIIT Key Laboratory of Advanced Display Materials and Devices, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
| | - Lianfu Jiang
- Institute of Optoelectronics & Nanomaterials, MIIT Key Laboratory of Advanced Display Materials and Devices, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
| | - Gangling Tong
- Department of Oncology, Peking University Shenzhen Hospital, Shenzhen Key Laboratory of Gastrointestinal Cancer Translational Research, Cancer Institute of Shenzhen-PKU-HKUST Medical Center, Shenzhen, 518036, China
| | - Yunhai Xiong
- Institute of Optoelectronics & Nanomaterials, MIIT Key Laboratory of Advanced Display Materials and Devices, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
| | - Karim Khan
- International Collaborative Laboratory of 2D Materials for Optoelectronics Science and Technology of Ministry of Education, Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, 518060, China
| | - Zhongmin Tang
- Center for Nanomedicine and Department of Anesthesiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Xiang Chen
- Institute of Optoelectronics & Nanomaterials, MIIT Key Laboratory of Advanced Display Materials and Devices, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
| | - Haibo Zeng
- Institute of Optoelectronics & Nanomaterials, MIIT Key Laboratory of Advanced Display Materials and Devices, School of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
| |
Collapse
|
22
|
Huang D, Xiang N. Rapid and precise tumor cell separation using the combination of size-dependent inertial and size-independent magnetic methods. LAB ON A CHIP 2021; 21:1409-1417. [PMID: 33605279 DOI: 10.1039/d0lc01223h] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Circulating tumor cells (CTCs) play a significant role in cancer diagnosis and treatment monitoring. One of the major challenges in isolating and detecting rare CTCs from blood is that white blood cells (WBCs) have a size overlap with the target CTCs. To address this issue, we constructed a three-stage i-Mag device integrated with passive inertial microfluidics and active magnetophoresis, enabling rapid and precise separation of tumor cells from blood. The first-stage spiral inertial sorter was applied to rapidly remove small-sized red blood cells (RBCs), and then the second-stage serpentine inertial focuser and the third-stage magnetic sorter were used for removing the magnetically labeled WBCs size-independently, to significantly purify the captured tumor cells. Then, the separation performance of our i-Mag device was explored. The results indicated rapid and precise separation of breast cancer cells from diluted whole blood at a high separation efficiency of 93.84% and at a high purity of 51.47%. The purity of the collected tumor cells could be further improved to 93.60% when the blood dilution ratio was increased. We also successfully applied our i-Mag device for the isolation and detection of trace tumor cells. Our i-Mag device has numerous advantages, such as enabling high-throughput processing and high-precision separation, requiring easy manufacturing at a low cost, and providing tumor antigen-independent operation. We believe that the i-Mag device has great potential to act as a precise tool for separating various bioparticles.
Collapse
Affiliation(s)
- Di Huang
- School of Mechatronic Engineering, China University of Mining and Technology, Xuzhou 221116, P.R. China
| | | |
Collapse
|
23
|
Liu Y, Xu H, Li T, Wang W. Microtechnology-enabled filtration-based liquid biopsy: challenges and practical considerations. LAB ON A CHIP 2021; 21:994-1015. [PMID: 33710188 DOI: 10.1039/d0lc01101k] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Liquid biopsy, an important enabling technology for early diagnosis and dynamic monitoring of cancer, has drawn extensive attention in the past decade. With the rapid developments of microtechnology, it has been possible to manipulate cells at the single-cell level, which dramatically improves the liquid biopsy capability. As the microtechnology-enabled liquid biopsy matures from proof-of-concept demonstrations towards practical applications, a main challenge it is facing now is to process clinical samples which are usually of a large volume while containing very rare targeted cells in complex backgrounds. Therefore, a high-throughput liquid biopsy which is capable of processing liquid samples with a large volume in a reasonable time along with a high recovery rate of rare targeted cells from complex clinical liquids is in high demand. Moreover, the purity, viability and release feasibility of recovered targeted cells are the other three key impact factors requiring careful considerations. To date, among the developed techniques, micropore-type filtration has been acknowledged as the most promising solution to address the aforementioned challenges in practical applications. However, the presently reported studies about micropore-type filtration are mostly based on trial and error for device designs aiming at different cancer types, which requires lots of efforts. Therefore, there is an urgent need to investigate and elaborate the fundamental theories of micropore-type filtration and key features that influence the working performances in the liquid biopsy of real clinical samples to promote the application efficacy in practical applications. In this review, the state of the art of microtechnology-enabled filtration is systematically and comprehensively summarized. Four key features of the filtration, including throughput, purity, viability and release feasibility of the captured targeted cells, are elaborated to provide the guidelines for filter designs. The recent progress in the filtration mode modulation and sample standardization to improve the filtration performance of real clinical samples is also discussed. Finally, this review concludes with prospective views for future developments of filtration-based liquid biopsy to promote its application efficacy in clinical practice.
Collapse
Affiliation(s)
- Yaoping Liu
- Institute of Microelectronics, Peking University, Beijing, 100871, China.
| | | | | | | |
Collapse
|
24
|
Design and Clinical Application of an Integrated Microfluidic Device for Circulating Tumor Cells Isolation and Single-Cell Analysis. MICROMACHINES 2021; 12:mi12010049. [PMID: 33401770 PMCID: PMC7824094 DOI: 10.3390/mi12010049] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 12/27/2020] [Accepted: 12/30/2020] [Indexed: 12/20/2022]
Abstract
Circulating tumor cells (CTCs) have been considered as an alternative to tissue biopsy for providing both germline-specific and tumor-derived genetic variations. Single-cell analysis of CTCs enables in-depth investigation of tumor heterogeneity and individualized clinical assessment. However, common CTC enrichment techniques generally have limitations of low throughput and cell damage. Herein, based on micropore-arrayed filtration membrane and microfluidic chip, we established an integrated CTC isolation platform with high-throughput, high-efficiency, and less cell damage. We observed a capture rate of around 85% and a purity of 60.4% by spiking tumor cells (PC-9) into healthy blood samples. Detection of CTCs from lung cancer patients demonstrated a positive detectable rate of 87.5%. Additionally, single CTCs, ctDNA and liver biopsy tissue of a representative advanced lung cancer patient were collected and sequenced, which revealed comprehensive genetic information of CTCs while reflected the differences in genetic profiles between different biological samples. This work provides a promising tool for CTCs isolation and further analysis at single-cell resolution with potential clinical value.
Collapse
|
25
|
Abdulla A, Zhang T, Ahmad KZ, Li S, Lou J, Ding X. Label-free Separation of Circulating Tumor Cells Using a Self-Amplified Inertial Focusing (SAIF) Microfluidic Chip. Anal Chem 2020; 92:16170-16179. [PMID: 33232155 DOI: 10.1021/acs.analchem.0c03920] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Circulating tumor cells (CTCs) are rare cells existing in the bloodstream with a relatively low number, which facilitate as a predictor of cancer progress. However, it is difficult to obtain highly purified intact CTCs with desired viability due to the low percentage of CTCs among blood cells. In this work, we demonstrate a novel self-amplified inertial focused (SAIF) microfluidic chip that enables size-based, high-throughput, label-free separation of CTCs from a patient's blood. The SAIF chip introduced in this study demonstrated the feasibility of an extremely narrow zigzag channel (with 40 μm channel width) connected with two expansion regions to effectively separate different-sized cells with amplified separation distance. The chip performance was optimized with different-sized polystyrene (PS) particles and blood cells spiked with three different types of cancer cells. The separation efficiencies for blood cells and spiked cancer cells are higher than 80%. Recovery rates of cancer cells were tested by spiking 1500 lung cancer cells (A549), breast cancer cells (MCF-7), and cervical cancer cells (HeLa) separately to 3 mL 0.09% saline with 3 × 106 white blood cells (WBCs). The recovery rates for larger cells (MCF-7 and HeLa) were 79.1 and 85.4%, respectively. Viabilities of the cells harvested from outlets were all higher than 97% after culturing for 24, 48, and 72 h. The SAIF chip performance was further confirmed using the real clinical patient blood samples from four lung cancer patients. Theoretical force balance analysis in physics, computational simulations, and experimental observations indicate that the SAIF chip is simple but effective, and high-throughput separation CTCs can be readily achieved without complex structures.
Collapse
Affiliation(s)
- Aynur Abdulla
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954, Huashan Road, Shanghai 200030, China
| | - Ting Zhang
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954, Huashan Road, Shanghai 200030, China
| | - Khan Zara Ahmad
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954, Huashan Road, Shanghai 200030, China
| | - Shanhe Li
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954, Huashan Road, Shanghai 200030, China
| | - Jiatao Lou
- Department of Laboratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 Huaihai West Road, Shanghai 200030, China
| | - Xianting Ding
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, School of Biomedical Engineering, Shanghai Jiao Tong University, No. 1954, Huashan Road, Shanghai 200030, China
| |
Collapse
|
26
|
Quan Y, Chen K, Xiang N, Ni Z. A single-view field filter device for rare tumor cell filtration and enumeration. Electrophoresis 2020; 41:2000-2006. [PMID: 32767389 DOI: 10.1002/elps.202000176] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 07/27/2020] [Accepted: 08/03/2020] [Indexed: 12/11/2022]
Abstract
In this work, we demonstrate a single-view field filter (SVFF) device for the efficient filtration and enumeration of rare tumor cells in the blood. In our device, the track-etched membrane is integrated within a low-cost polymer-film microfluidic chip, and multiplex microfiltration chambers are designed. Our device permits the performing of multiple sample tests on a single membrane and the dynamical observation of the entire filtration process in a single field of view. To characterize the device performance, our device is first tested using tumor cells, and three different cell behaviors are observed during the filtration process. Finally, we successfully apply our device for the separation of rare tumor cells from the lysed blood samples at various flow rates. The recovery rates of 93.3, 87.6, and 84.1% can be respectively achieved at the throughputs of 50, 100, and 150 μL/min. Our single-view field filter (SVFF) device offers the advantages of label-free filtration, efficient enumeration, easy integration, and low cost, and holds the potential to be used as an efficient tool for the filtration and enumeration of rare cells.
Collapse
Affiliation(s)
- Yunlin Quan
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Ke Chen
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| |
Collapse
|
27
|
Akpe V, Kim TH, Brown CL, Cock IE. Circulating tumour cells: a broad perspective. J R Soc Interface 2020; 17:20200065. [PMCID: PMC7423436 DOI: 10.1098/rsif.2020.0065] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 07/09/2020] [Indexed: 08/13/2023] Open
Abstract
Circulating tumour cells (CTCs) have recently been identified as valuable biomarkers for diagnostic and prognostic evaluations, as well for monitoring therapeutic responses to treatments. CTCs are rare cells which may be present as one CTC surrounded by approximately 1 million white blood cells and 1 billion red blood cells per millilitre of peripheral blood. Despite the various challenges in CTC detection, considerable progress in detection methods have been documented in recent times, particularly for methodologies incorporating nanomaterial-based platforms and/or integrated microfluidics. Herein, we summarize the importance of CTCs as biological markers for tumour detection, highlight their mechanism of cellular invasion and discuss the various challenges associated with CTC research, including vulnerability, heterogeneity, phenotypicity and size differences. In addition, we describe nanomaterial agents used for electrochemistry and surface plasmon resonance applications, which have recently been used to selectively capture cancer cells and amplify signals for CTC detection. The intrinsic properties of nanomaterials have also recently been exploited to achieve photothermal destruction of cancer cells. This review describes recent advancements and future perspectives in the CTC field.
Collapse
Affiliation(s)
- Victor Akpe
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia
- Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Tak H. Kim
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia
- Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Christopher L. Brown
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia
- Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| | - Ian E. Cock
- School of Environment and Science, Griffith University, Nathan Campus, Queensland 4111, Australia
- Environmental Futures Research Institute, Griffith University, Nathan Campus, Queensland 4111, Australia
| |
Collapse
|
28
|
Li T, Liu Y, Zhang W, Lin L, Zhang J, Xiong Y, Nie L, Liu X, Li H, Wang W. A rapid liquid biopsy of lung cancer by separation and detection of exfoliated tumor cells from bronchoalveolar lavage fluid with a dual-layer "PERFECT" filter system. Theranostics 2020; 10:6517-6529. [PMID: 32483467 PMCID: PMC7255025 DOI: 10.7150/thno.44274] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Accepted: 04/19/2020] [Indexed: 12/24/2022] Open
Abstract
Separation and detection of exfoliated tumor cells (ETCs) from bronchoalveolar lavage fluid (BALF), namely the liquid biopsy of BALF, has been proved to be a valuable tool for the diagnosis of lung cancer. Herein, we established a rapid liquid biopsy of BALF based on a dual-layer PERFECT (precise, efficient, rapid, flexible, easy-to-operate, controllable and thin) filter system for the first time. Methods: The dual-layer PERFECT filter system consists of an upper-layer filter with large micropores (feature size of 49.4 ± 0.5 μm) and a lower-layer filter with small micropores (9.1 ± 0.1 μm). The upper-layer filter contributes to the isolation of cell clusters and removal of mucus from BALF samples, meanwhile the lower-layer one targets for the separation of single ETCs. First, separation of 10000 spiked A549s (cultured lung cancer cells) from 10 mL clinical BALF samples (n=3) were performed to investigate the performance of the proposed system in rare cell separation. Furthermore, separation and detection of ETCs and ETC clusters from clinical BALF samples were performed with this system to test its efficacy and compared with the routine cytocentrifuge. The clinical BALF samples were collected from 33 lung cancer-suspected patients with visible lesions under bronchoscope. The final histopathological results showed that 20 samples were from lung cancer positive patients while the other 13 cases were from lung cancer negative patients. Results: The recovery rate of spiked A549 cells from clinical BALF samples with the developed system (89.8 ± 5.2%) is significantly higher than that with the cytocentrifuge (13.6 ± 7.8%). In the preliminary clinical trial, although 33 clinical BALF samples with volume ranging from 6 mL to 18 mL showed greatly varied turbidity, filtrations could be finished within 3 min for 54.6% of samples (18/33), and 10 min at most for the rest. The dual-layer PERFECT filter system is proved to have a much higher sensitivity (80.0%, 95% CI: 55.7%-93.4%) than the routine cytocentrifuge (45.0%, 95% CI: 23.8%-68.0%), p=0.016 (McNemar test, two-tail). Moreover, the sensitivity of this platform is neither interfered by the variations of turbidity of the BALF samples, nor associated with the types of lung cancer. Conclusions: The easy and rapid processing of BALF samples with varying volume and turbidity, competitive sensitivity and good versatility for different lung cancer types will make the established dual-layer PERFECT filter system a promising approach for the liquid biopsy of BALF. The high-performance BALF-based liquid biopsy will improve the cytopathological identification and diagnosis of lung cancer.
Collapse
Affiliation(s)
- Tingyu Li
- Institute of Microelectronics, Peking University, Beijing, 100871, China
| | - Yaoping Liu
- Institute of Microelectronics, Peking University, Beijing, 100871, China
- Antimicrobial Resistance (AMR) and Critical Analytics for Manufacturing Personalized-Medicine (CAMP) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore, 138602, Singapore
| | - Wei Zhang
- Department of Respiratory and Critical Care Medicine, Peking University First Hospital, Beijing, 100034, China
| | - Lianjun Lin
- Department of Geriatrics, Peking University First Hospital, Beijing, 100034, China
| | - Jixin Zhang
- Department of Pathology, Peking University First Hospital, Beijing, 100034, China
| | - Yan Xiong
- Department of Pathology, Peking University First Hospital, Beijing, 100034, China
| | - Ligong Nie
- Department of Respiratory and Critical Care Medicine, Peking University First Hospital, Beijing, 100034, China
| | - Xinmin Liu
- Department of Geriatrics, Peking University First Hospital, Beijing, 100034, China
| | - Haichao Li
- Department of Respiratory and Critical Care Medicine, Peking University First Hospital, Beijing, 100034, China
| | - Wei Wang
- Institute of Microelectronics, Peking University, Beijing, 100871, China
- National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Beijing, 100871, China
- Frontiers Science Center for Nano-optoelectronics, Peking University, Beijing, 100871, China
| |
Collapse
|
29
|
Yee-de León JF, Soto-García B, Aráiz-Hernández D, Delgado-Balderas JR, Esparza M, Aguilar-Avelar C, Wong-Campos JD, Chacón F, López-Hernández JY, González-Treviño AM, Yee-de León JR, Zamora-Mendoza JL, Alvarez MM, Trujillo-de Santiago G, Gómez-Guerra LS, Sánchez-Domínguez CN, Velarde-Calvillo LP, Abarca-Blanco A. Characterization of a novel automated microfiltration device for the efficient isolation and analysis of circulating tumor cells from clinical blood samples. Sci Rep 2020; 10:7543. [PMID: 32372001 PMCID: PMC7200708 DOI: 10.1038/s41598-020-63672-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Accepted: 04/03/2020] [Indexed: 12/20/2022] Open
Abstract
The detection and analysis of circulating tumor cells (CTCs) may enable a broad range of cancer-related applications, including the identification of acquired drug resistance during treatments. However, the non-scalable fabrication, prolonged sample processing times, and the lack of automation, associated with most of the technologies developed to isolate these rare cells, have impeded their transition into the clinical practice. This work describes a novel membrane-based microfiltration device comprised of a fully automated sample processing unit and a machine-vision-enabled imaging system that allows the efficient isolation and rapid analysis of CTCs from blood. The device performance was characterized using four prostate cancer cell lines, including PC-3, VCaP, DU-145, and LNCaP, obtaining high assay reproducibility and capture efficiencies greater than 93% after processing 7.5 mL blood samples spiked with 100 cancer cells. Cancer cells remained viable after filtration due to the minimal shear stress exerted over cells during the procedure, while the identification of cancer cells by immunostaining was not affected by the number of non-specific events captured on the membrane. We were also able to identify the androgen receptor (AR) point mutation T878A from 7.5 mL blood samples spiked with 50 LNCaP cells using RT-PCR and Sanger sequencing. Finally, CTCs were detected in 8 out of 8 samples from patients diagnosed with metastatic prostate cancer (mean ± SEM = 21 ± 2.957 CTCs/mL, median = 21 CTCs/mL), demonstrating the potential clinical utility of this device.
Collapse
Affiliation(s)
| | | | | | - Jesús Rolando Delgado-Balderas
- Delee Corp., Mountain View, CA, 94041, USA.,Departamento de Bioquímica y Medicina Molecular, Facultad de Medicina, Universidad Autónoma de Nuevo León, Monterrey, 64460, Mexico
| | | | | | - J D Wong-Campos
- Delee Corp., Mountain View, CA, 94041, USA.,Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, 02138, USA
| | | | | | | | | | | | - Mario M Alvarez
- Centro de Biotecnología-FEMSA, Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Monterrey, 64849, Mexico.,Departamento de Bioingeniería, Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Monterrey, 64849, Mexico
| | - Grissel Trujillo-de Santiago
- Centro de Biotecnología-FEMSA, Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Monterrey, 64849, Mexico.,Departamento de Mecatrónica e Ingeniería Eléctrica, Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Monterrey, 64849, Mexico
| | - Lauro S Gómez-Guerra
- Servicio de Urología, Hospital Universitario "Dr. José Eleuterio González", Universidad Autónoma de Nuevo León, Monterrey, 64460, Mexico
| | - Celia N Sánchez-Domínguez
- Departamento de Bioquímica y Medicina Molecular, Facultad de Medicina, Universidad Autónoma de Nuevo León, Monterrey, 64460, Mexico
| | | | | |
Collapse
|
30
|
Xiang N, Li Q, Shi Z, Zhou C, Jiang F, Han Y, Ni Z. Low-cost multi-core inertial microfluidic centrifuge for high-throughput cell concentration. Electrophoresis 2019; 41:875-882. [PMID: 31705675 DOI: 10.1002/elps.201900385] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 10/25/2019] [Accepted: 11/05/2019] [Indexed: 12/12/2022]
Abstract
We developed a low-cost multi-core inertial microfluidic centrifuge (IM-centrifuge) to achieve a continuous-flow cell/particle concentration at a throughput of up to 20 mL/min. To lower the cost of our IM-centrifuge, we clamped a disposable multilayer film-based inertial microfluidic (MFIM) chip with two reusable plastic housings. The key MFIM chip was fabricated in low-cost materials by stacking different polymer-film channel layers and double-sided tape. To increase processing throughput, multiplexing spiral inertial microfluidic channels were integrated within an all-in-one MFIM chip, and a novel sample distribution strategy was employed to equally distribute the sample into each channel layer. Then, we characterized the focusing performance in the MFIM chip over a wide flow-rate range. The experimental results showed that our IM-centrifuge was able to focus various-sized particles/cells to achieve volume reduction. The sample distribution strategy also effectively ensured identical focusing and concentration performances in different cores. Finally, our IM-centrifuge was successfully applied to concentrate microalgae cells with irregular shapes and highly polydisperse sizes. Thus, our IM-centrifuge holds the potential to be employed as a low-cost, high-throughput centrifuge for disposable use in low-resource settings.
Collapse
Affiliation(s)
- Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Qiao Li
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Zhiguo Shi
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Chenguang Zhou
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Fengtao Jiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Yu Han
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| |
Collapse
|
31
|
Xu M, Zhao H, Chen J, Liu W, Li E, Wang Q, Zhang L. An Integrated Microfluidic Chip and Its Clinical Application for Circulating Tumor Cell Isolation and Single-Cell Analysis. Cytometry A 2019; 97:46-53. [PMID: 31595638 DOI: 10.1002/cyto.a.23902] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 08/27/2019] [Accepted: 09/13/2019] [Indexed: 12/16/2022]
Abstract
Circulating tumor cells (CTCs) represent invasive tumor cell populations and provide a noninvasive solution to the clinical management and research of tumors. Characterization of CTCs at single-cell resolution enables the comprehensive understanding of tumor heterogeneity and may benefit the diagnosis and treatment of cancer patients. However, most efforts have been made on enumeration and detection of CTCs, while little focus has been directed to single-cell study. Herein, an integrated microfluidic platform for single-cell isolation and analysis was established. After validating this platform on lung cancer cell lines, we detected and isolated single CTCs from the peripheral blood samples of 20 cancer patients before and after one treatment cycle. Furthermore, we performed single-cell whole-exome DNA sequencing on a single CTC from the peripheral blood sample of a representative early stage lung cancer patient. Among the blood samples of 20 patients, 15 of them were positive for CTC detection (75.0% detectable rate). Single-cell analysis revealed detailed genetic variations of the CTC, while six new gene mutations were detected in both single CTC and surgical specimen. This study provides a useful tool for the isolation and analysis of single CTCs from peripheral blood samples, which not only facilitates the early diagnosis of cancers but also helps to unravel the genetic information of tumor at a single-cell level. © 2019 International Society for Advancement of Cytometry.
Collapse
Affiliation(s)
- Mingxin Xu
- Department of Respiratory Medicine, The Second Hospital Affiliated to Dalian Medical University, Dalian, 116044, China
| | - Hui Zhao
- Department of Respiratory Medicine, The Second Hospital Affiliated to Dalian Medical University, Dalian, 116044, China
| | - Jun Chen
- Department of Oncology, The Second Hospital Affiliated to Dalian Medical University, Dalian, 116044, China
| | - Wenwen Liu
- Department of Respiratory Medicine, The Second Hospital Affiliated to Dalian Medical University, Dalian, 116044, China
| | - Encheng Li
- Department of Respiratory Medicine, The Second Hospital Affiliated to Dalian Medical University, Dalian, 116044, China
| | - Qi Wang
- Department of Respiratory Medicine, The Second Hospital Affiliated to Dalian Medical University, Dalian, 116044, China
| | - Lichuan Zhang
- Department of Respiratory Medicine, Affiliated Zhongshan Hospital of Dalian University, Dalian, 116001, China
| |
Collapse
|
32
|
Tian F, Liu C, Lin L, Chen Q, Sun J. Microfluidic analysis of circulating tumor cells and tumor-derived extracellular vesicles. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.05.013] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
33
|
Xiang N, Wang J, Li Q, Han Y, Huang D, Ni Z. Precise Size-Based Cell Separation via the Coupling of Inertial Microfluidics and Deterministic Lateral Displacement. Anal Chem 2019; 91:10328-10334. [DOI: 10.1021/acs.analchem.9b02863] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Jie Wang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Qiao Li
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Yu Han
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Di Huang
- School of Mechatronic Engineering, China University of Mining and Technology, Xuzhou, 221116, China
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| |
Collapse
|
34
|
Chen D, Wen J, Zeng S, Ma H. DNA fragment‐assisted microfluidic chip for capture and release of circulating tumor cells. Electrophoresis 2019; 40:2845-2852. [DOI: 10.1002/elps.201900165] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Revised: 06/28/2019] [Accepted: 07/01/2019] [Indexed: 12/18/2022]
Affiliation(s)
- Dengyi Chen
- College of Laboratory MedicineDalian Medical University Dalian Liaoning Province P. R. China
| | - Jing Wen
- College of Laboratory MedicineDalian Medical University Dalian Liaoning Province P. R. China
| | - Shaojiang Zeng
- College of Laboratory MedicineDalian Medical University Dalian Liaoning Province P. R. China
| | - Huipeng Ma
- College of Laboratory MedicineDalian Medical University Dalian Liaoning Province P. R. China
| |
Collapse
|