1
|
Zhang B, Fu J, Du M, Jin K, Huang Q, Li J, Wang D, Hu S, Li J, Ma H. Polar coordinate active-matrix digital microfluidics for high-resolution concentration gradient generation. LAB ON A CHIP 2024; 24:2193-2201. [PMID: 38465383 DOI: 10.1039/d3lc00979c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
Automated concentration gradient generation is one of the most important applications of lab-on-a-chip devices. Digital microfluidics is a unique platform that can effectively achieve digitalized gradient concentration preparation. However, the dynamic range and concentration resolution of the prepared samples heavily rely on the size and the number of effective electrodes. In this work, we report an active-matrix digital microfluidic device with polar coordinate electrode arrangement. The device contains 33 different electrode sizes, generating digital droplets of different volumes. To compare with the conventional rectangular coordinate arrangement with a similar electrode number, this work shows an approximately 19 times resolution enhancement for the achievable concentration gradient. We characterized the stability and uniformity of droplets generated by electrodes of different sizes, and the coefficient of variation of stable droplets was less than 3%. The fluorescent nanomaterial's concentration quantification and glucose concentration characterization experiments were also conducted, and the correlation coefficients for the linearities were all above 0.99.
Collapse
Affiliation(s)
- Bingbing Zhang
- Nanophotonics and Biophotonics Key Laboratory of Jilin Province, Changchun University of Science and Technology, Changchun, 130022, P. R. China.
- CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China.
| | - Jinxin Fu
- CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China.
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230027, Anhui, P. R. China
| | - Maohua Du
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China
| | - Kai Jin
- CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China.
| | - Qi Huang
- CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China.
| | - Jiahao Li
- ACX Instruments Ltd, St John's Innovation Centre, Cowley Road, Cambridge, CB4 0WS, UK
| | - Dongping Wang
- CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China.
| | - Siyi Hu
- CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China.
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China
| | - Jinhua Li
- Nanophotonics and Biophotonics Key Laboratory of Jilin Province, Changchun University of Science and Technology, Changchun, 130022, P. R. China.
| | - Hanbin Ma
- CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China.
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China
| |
Collapse
|
2
|
Wu J, Zhang M, Huang J, Guan J, Hu C, Shi M, Hu S, Wang S, Ma H. Enhanced absorbance detection system for online bacterial monitoring in digital microfluidics. Analyst 2023; 148:4659-4667. [PMID: 37615041 DOI: 10.1039/d3an01049j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
We report a fully integrated digital microfluidic absorbance detection system with an enhanced sensitivity for online bacterial monitoring. Through a 100 μm gap in the chip, our optical detection system has a detection sensitivity for a BCA protein concentration of 0.1 mg mL-1. The absorbance detection limit of our system is 1.4 × 10-3 OD units, which is one order of magnitude better than that of the existing studies. The system's linear region is 0.1-7 mg mL-1, and the dynamic range is 0-25 mg mL-1. We measured the growth curves of wild-type and E. coli transformed with resistance plasmids and mixed at different ratios on chip. We sorted out the bacterial species including highly viable single cells based on the difference in absorbance data of growth curves. We explored the changes in the growth curves of E. coli under different concentrations of resistant media. In addition, we successfully screened for the optimal growth environment of the bacteria, in which the growth rate of PET30a-DH5α (in a medium with 33 μg mL-1 kanamycin resistance) was significantly higher than that of a 1 mg mL-1 resistance medium. In conclusion, the enhanced digital microfluidic absorbance detection system exhibits exceptional sensitivity, enabling precise bacterial monitoring and growth curve analysis, while also laying the foundation for DMF-based automated bioresearch platforms, thus advancing research in the life sciences.
Collapse
Affiliation(s)
- Jingya Wu
- Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528225, P. R. China.
| | - Maolin Zhang
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230027, Anhui, P. R. China
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, P. R. China.
| | - Jianle Huang
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China
| | - Jingxin Guan
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China
| | - Chenxuan Hu
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230027, Anhui, P. R. China
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, P. R. China.
| | - Mude Shi
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China
| | - Siyi Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, P. R. China.
| | - Shurong Wang
- Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528225, P. R. China.
| | - Hanbin Ma
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, P. R. China.
- Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China
| |
Collapse
|
3
|
All-in-One Digital Microfluidics System for Molecular Diagnosis with Loop-Mediated Isothermal Amplification. BIOSENSORS 2022; 12:bios12050324. [PMID: 35624625 PMCID: PMC9138765 DOI: 10.3390/bios12050324] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 05/08/2022] [Accepted: 05/09/2022] [Indexed: 11/17/2022]
Abstract
In this study, an “all-in-one” digital microfluidics (DMF) system was developed for automatic and rapid molecular diagnosis and integrated with magnetic bead-based nucleic acid extraction, loop-mediated isothermal amplification (LAMP), and real-time optical signal monitoring. First, we performed on- and off-chip comparison experiments for the magnetic bead nucleic acid extraction module and LAMP amplification function. The extraction efficiency for the on-chip test was comparable to that of conventional off-chip methods. The processing time for the automatic on-chip workflow was only 23 min, which was less than that of the conventional methods of 28 min 45 s. Meanwhile, the number of samples used in on-chip experiments was significantly smaller than that used in off-chip experiments; only 5 µL of E. coli samples was required for nucleic acid extraction, and 1 µL of the nucleic acid template was needed for the amplification reaction. In addition, we selected SARS-CoV-2 nucleic acid reference materials for the nucleic acid detection experiment, demonstrating a limit of detection of 10 copies/µL. The proposed “all-in-one” DMF system provides an on-site “sample to answer” time of approximately 60 min, which can be a powerful tool for point-of-care molecular diagnostics.
Collapse
|
4
|
Barman SR, Khan I, Chatterjee S, Saha S, Choi D, Lee S, Lin ZH. Electrowetting-on-dielectric (EWOD): Current perspectives and applications in ensuring food safety. J Food Drug Anal 2020; 28:595-621. [PMID: 35696148 PMCID: PMC9261810 DOI: 10.38212/2224-6614.1239] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Revised: 06/08/2020] [Accepted: 07/03/2020] [Indexed: 11/18/2022] Open
Abstract
Digital microfluidic (DMF) platforms have contributed immensely to the development of multifunctional lab-on-chip systems for performing complete sets of biological and analytical assays. Electrowetting-on-dielectric (EWOD) technology, due to its outstanding flexibility and integrability, has emerged as a promising candidate for such lab-on-chip applications. Triggered by an electrical stimulus, EWOD devices allow precise manipulation of single droplets along the designed electrode arrays without employing external pumps and valves, thereby enhancing the miniaturization and portability of the system towards transcending important laboratory assays in resource-limited settings. In recent years, the simple fabrication process and reprogrammable architecture of EWOD chips have led to their widespread applications in food safety analysis. Various EWOD devices have been developed for the quantitative monitoring of analytes such as food-borne pathogens, heavy metal ions, vitamins, and antioxidants, which are significant in food samples. In this paper, we reviewed the advances and developments in the design of EWOD systems for performing versatile functions starting from sample preparation to sample detection, enabling rapid and high-throughput food analysis.
Collapse
Affiliation(s)
- Snigdha Roy Barman
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu 30013,
Taiwan
| | - Imran Khan
- Institute of NanoEngineering and Microsystems, National Tsing Hua University, Hsinchu 30013,
Taiwan
| | - Subhodeep Chatterjee
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013,
Taiwan
| | - Subhajit Saha
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu 30013,
Taiwan
| | - Dukhyun Choi
- Department of Mechanical Engineering, Kyung Hee University, Yongin, 17104,
South Korea
| | - Sangmin Lee
- School of Mechanical Engineering, Chung-Ang University, Seoul 06974,
South Korea
| | - Zong-Hong Lin
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu 30013,
Taiwan
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013,
Taiwan
- Department of Mechanical Engineering, Kyung Hee University, Yongin, 17104,
South Korea
| |
Collapse
|