1
|
Kim A, Kelly PF, Turner MA, Reynolds JC. A direct analysis method using sheath flow probe electrospray ionisation-mass spectrometry (sfPESI-MS) to detect drug residues from fingerprint forensic gel lifts. Drug Test Anal 2024. [PMID: 38589994 DOI: 10.1002/dta.3688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 03/04/2024] [Accepted: 03/14/2024] [Indexed: 04/10/2024]
Abstract
Latent fingerprints at crime scenes are frequently recovered using forensic gel-lifters, which can help to preserve the crime scene and to enhance visualisation of traces such as blood or paint. In addition to providing fingerprint ridge detail, additional chemical information can also be recovered from gel lifts that may prove pertinent to an investigation. However, while DNA and metal ions have been shown to be able to be detected in gel-lifted fingerprints, the determination of other types of chemical information such as the presence of drugs in gel-lifted prints has not been previously shown. This study demonstrates the application of an ambient ionisation method, sheath flow probe electrospray ionisation-mass spectrometry (sfPESI-MS), to the direct analysis of gel-lifted fingerprints. A model drug compound (zolpidem) is successfully detected from gel-lifted prints from three different surface types: glass, metal, and paper. The surface activity-based separation associated with probe electrospray approaches is shown to resolve zolpidem ions from background phthalate species, significantly enhancing the response obtained from the gel-lifter. A depletion series experiment shows that the drug residue can be detected with up to 100% efficiency after eight consecutive contacts; however, detection efficiency drops to 20% after 30 contacts. The developed approach has potential application to analysis of historical gel-lifters to obtain additional chemical information.
Collapse
Affiliation(s)
- Ayoung Kim
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
| | - Paul F Kelly
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
| | - Matthew A Turner
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
| | - James C Reynolds
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
| |
Collapse
|
2
|
Millán-Santiago J, Lucena R, Cárdenas S. Bioinspired composite packed in blunt needles, integrated microextraction and determination of oxycodone and naloxone in saliva by substrate spray mass spectrometry. Anal Chim Acta 2024; 1297:342376. [PMID: 38438230 DOI: 10.1016/j.aca.2024.342376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 02/02/2024] [Accepted: 02/13/2024] [Indexed: 03/06/2024]
Abstract
BACKGROUND Opioids are effective painkillers used for medical purposes. Their prolonged ingestion can provoke some side effects (including overdose or constipation) that are minimized by using opioid antagonists (e.g., naloxone). The rapid determination of opioids and their antagonists in biosamples is essential for an effective medical treatment. The direct combination of sample preparation and mass spectrometry (MS) fits well in this scenario. It can speed up the analysis achieving a good selectivity, which relies on the sample preparation and MS, and sensitivity levels. RESULTS This article presents a novel substrate-spray mass spectrometry interface based on a polydopamine-cotton (PDA-Cel) composite hosted inside the inner diameter of a 14-gauge blunt needle to determine oxycodone and naloxone in saliva samples. The needle is used as a microextraction device and a substrate for mass spectrometric analysis. The lack of sharpness of the 14-gauge (14G) blunt needles challenges the formation of the electrospray (ESI), and a commercial 10 μL pipette tip is proposed as a simple solution to this shortcoming. Under the optimum parameters, the proposed method was validated, obtaining limits of detection lower than 0.6 μg L-1, linear range up to 200 μg L-1, and linearity better than 0.9915. Relative standard deviation (RSD) and relative recoveries (RR) were studied at three different concentration levels (2, 40, and 200 μg L-1). RSD values were better than 20.7 %, and RR ranged from 90 to 114 %. Finally, a positive sample from a patient under medical treatment was analyzed. SIGNIFICANCE AND NOVELTY 14G blunt needles have been demonstrated as effective extraction devices due to their low price (<0.15 € per extraction unit), their better safety (avoiding finger pricking), and their higher hosting capacity (up to 8 mg of sorbent). The conductivity of stainless steel permits their use as electrospray emitters, making their direct combination to MS easier. The large variety of fibrous sorbents makes this approach versatile enough to be adapted to other analytical problems.
Collapse
Affiliation(s)
- Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain.
| |
Collapse
|
3
|
Brown CO, Westring CG, Danielson PB, Legg KM. Saliva identification in forensic samples by automated microextraction and intact mass analysis of statherin. J Forensic Sci 2024; 69:640-650. [PMID: 38173363 DOI: 10.1111/1556-4029.15445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 11/09/2023] [Accepted: 11/27/2023] [Indexed: 01/05/2024]
Abstract
The enzyme α-amylase has long been a commonly targeted protein in serological tests for saliva. While being especially abundant in saliva, α-amylase is detectable in vaginal secretions, sweat, fecal matter, breast milk and other matrices. As a result, assays for α-amylase only provide a presumptive indication of saliva. The availability of mass spectrometry-based tools for the detection of less abundant, but more specific, protein targets (e.g., human statherin) has enabled the development of high confidence assays for human saliva. Sample throughput, however, has traditionally been low due to multi-step workflows for protein extraction, quantitation, enzymatic digestion, solid phase cleanup, and nano-/capillary-based chromatography. Here, we present two novel "direct" single-stage extraction strategies for sample preparation. These feature immunoaffinity purification and reversed-phase solid-phase microextraction in conjunction with intact mass analysis of human statherin for saliva identification. Mass analysis was performed on the Thermo Scientific Q-Exactive™ Orbitrap mass spectrometer with a 10-min analytical run time. Data analysis was performed using Byos® from Protein Metrics. Two sample sets were analyzed with a population of 20 individuals to evaluate detection reliability. A series of casework-type samples were then assayed to evaluate performance in an authentic forensic context. Statherin was confidently identified in 92% and 71% of samples extracted using the immunoaffinity purification and solid phase microextraction approaches, respectively. Overall, immunoaffinity purification outperformed the solid phase microextraction, especially with complex mixtures. In toto, robotic extraction and intact mass spectrometry enable the reliable identification of trace human saliva in a variety of sample types.
Collapse
Affiliation(s)
- Catherine O Brown
- Department of Biological Sciences, The University of Denver, Denver, Colorado, USA
| | - Christian G Westring
- Center for Crime and Forensics, Purdue University Northwest, Hammond, Indiana, USA
| | - Phillip B Danielson
- Department of Biological Sciences, The University of Denver, Denver, Colorado, USA
| | | |
Collapse
|
4
|
Millán-Santiago J, Lucena R, Cárdenas S. Nylon 6-cellulose composite hosted in a hypodermic needle: Biofluid extraction and analysis by ambient mass spectrometry in a single device. J Pharm Anal 2023; 13:1346-1352. [PMID: 38174121 PMCID: PMC10759252 DOI: 10.1016/j.jpha.2023.06.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 05/28/2023] [Accepted: 06/27/2023] [Indexed: 01/05/2024] Open
Abstract
This study proposes a hypodermic needle (HN) as a sorbent holder and an electrospray (ESI) emitter, thus combining extraction and analysis in a single device. A novel nylon 6-cellulose (N6-Cel) composite sorbent is proposed to extract methadone from oral fluid samples. The cellulosic substrate provides the composite with high porosity, permitting the flow-through of the sample, while the polyamide contributes to the extraction of the analyte. The low price of the devices (considering the holder and the sorbent) contributes to the affordability of the method, and their small size allows easy transportation, opening the door to on-site extractions. Under the optimum conditions, the analyte can be determined by high-resolution ambient ionization mass spectrometry at a limit of detection (LOD) as low as 0.3 μg/L and precision (expressed as relative standard deviation, RSD) better than 9.3%. The trueness, expressed as relative recovery (RR), ranged from 90% to 109%. As high-resolution mass spectrometers are not available in many laboratories, the method was also adapted to low-resolution spectrometers. In this sense, the direct infusion of the eluates in a triple quadrupole-mass spectrometry provided an LOD of 2.2 μg/L. The RSD was better than 5.3%, and the RR ranged from 96% to 121%.
Collapse
Affiliation(s)
- Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| |
Collapse
|
5
|
Prunty S, Carmany D, Dhummakupt ES, Manicke NE. Combining presumptive color tests, pressure-sensitive adhesive-based collection, and paper spray-mass spectrometry for illicit drug detection. Analyst 2023. [PMID: 37377186 DOI: 10.1039/d3an00559c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/29/2023]
Abstract
Illicit drug trafficking and abuse is a significant public safety and health concern. Color tests are commonly used for drug screening, but their poor specificity results in false positives. This study demonstrates the combination of drug residue collection using pressure-sensitive adhesive paper, on-paper color testing, and post-reaction analysis by paper spray mass spectrometry (PS-MS) on both portable and benchtop ion trap MS. All steps, including residue collection, color testing, and paper spray analysis, were performed on the same piece of paper. Three common color tests were investigated: the cobalt thiocyanate test for cocaine, the Simon test for methamphetamine, and the Marquis test for phenethylamine stimulants and opiates. The detection threshold for color tests ranged from 1.25 to 10 μg on paper. Drug residues were successfully confirmed by paper spray MS at the color test threshold in all cases, except for heroin after reaction with the Marquis reagent, when using the portable MS. In this case, the MS detection threshold was 4-fold higher than the color test threshold. The stability of the color test products was assessed through a time study. Drug residues could be detected by MS at least 24 hours after reaction. A series of realistic samples, including false positives, were analyzed to demonstrate the technique's utility in real-world scenarios. Overall, combining color tests with PS-MS offers a rapid, low-cost method for the collection and analysis of illicit drugs.
Collapse
Affiliation(s)
- Sarah Prunty
- Indiana University-Purdue University Indianapolis, Indianapolis, IN, USA.
| | | | | | - Nicholas E Manicke
- Indiana University-Purdue University Indianapolis, Indianapolis, IN, USA.
| |
Collapse
|
6
|
Chen L, Ghiasvand A, Paull B. Applications of thread-based microfluidics: Approaches and options for detection. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
|
7
|
Kim A, Kelly PF, Turner MA, Reynolds JC. Development of a rapid, in-situ analysis method using sheath-flow probe electrospray ionisation-mass spectrometry for the direct identification of cocaine metabolites in dried blood spots. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2023; 37:e9422. [PMID: 36278930 PMCID: PMC9788050 DOI: 10.1002/rcm.9422] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/12/2022] [Accepted: 10/18/2022] [Indexed: 06/16/2023]
Abstract
RATIONALE Small amounts of biofluid samples are frequently found at crime scenes; however, existing gold standard methods such as LC-MS frequently require destructive extraction of the sample before a time-consuming analysis which puts strain on forensic analysis providers and can preclude further sample analysis. This study presents the application of sheath-flow probe electrospray ionization-mass spectrometry (sfPESI-MS) to the direct analysis of drug metabolites in dried blood spots (DBS) as a high throughput, minimally destructive alternative. METHODS A rapid direct analysis method using a sfPESI ionisation source coupled to an Orbitrap Exactive mass spectrometer was applied to detect cocaine metabolites (benzoylecgonine, BZE, cocaethylene, CE, and ecgonine methyl ester, EME) from DBS. An optimisation study exploring the use of different chemical modifiers (formic acid and sodium acetate) in the sfPESI probe extraction solvent was conducted to enhance the sensitivity and reproducibility of the sfPESI-MS method. RESULTS Optimisation of the extraction solvent significantly enhanced the sensitivity and reproducibility of the sfPESI-MS method. A quantitative response over a five-point calibration range 0.5 to 10 μg/ml was obtained for BZE (R2 = 0.9979) and CE (R2 = 0.9948). Limits of detection (LOD) of 1.31, 0.29 and 0.15 μg/ml were achieved for EME, BZE and CE, respectively, from 48 h aged DBSs with % RSD (relative standard deviation) across the calibration range ranging between 19%-28% for [BZE + H]+ , 13%-21% for [CE + H]+ and 12%-29% for [EME + H]+ . CONCLUSIONS A rapid (< 20 s) quantitative method for the direct analysis of cocaine metabolites from DBS which requires no prior sample preparation was developed. Although the LOD achieved for BZE (LOD: 0.29 μg/ml) was above the UK threshold limit of exposure for drug driving (0.05 μg/ml), the method may be suitable for use in identifying overdose in forensic analysis.
Collapse
Affiliation(s)
- Ayoung Kim
- Centre for Analytical Science, Department of ChemistryLoughborough UniversityUK
| | - Paul F. Kelly
- Centre for Analytical Science, Department of ChemistryLoughborough UniversityUK
| | - Matthew A. Turner
- Centre for Analytical Science, Department of ChemistryLoughborough UniversityUK
| | - James C. Reynolds
- Centre for Analytical Science, Department of ChemistryLoughborough UniversityUK
| |
Collapse
|
8
|
Rankin-Turner S, Heaney LM. Deployable Mass Spectrometry for Rapid On-Site Bioanalysis. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.lt8569n1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Benchtop liquid chromatography (LC)–mass spectrometry (LC–MS) and benchtop gas chromatography–MS (GC–MS) have been the gold standard in bioanalysis for decades, employed in clinical, forensic, and anti-doping laboratories worldwide. However, traditional instrumentation is subject to limitations that severely restrict the speed at which samples can be analyzed, the ease with which materials can be prepared, and the location where the analysis must be performed. With the advent of ambient ionization and portable mass spectrometers, the ability to perform rapid, on-site analysis is fast becoming a reality. Without the need for extensive sample preparation, analysis times as low as several seconds, and the ability to perform analysis remote from the laboratory, deployable mass spectrometers have the potential to revolutionize bioanalysis. However, several challenges must be tackled before this innovative technology can be widely adopted.
Collapse
|
9
|
Chen L, Ghiasvand A, Lam SC, Rodriguez ES, Innis PC, Paull B. Thread-based isotachophoresis coupled with desorption electrospray ionization mass spectrometry for clean-up, preconcentration, and determination of alkaloids in biological fluids. Anal Chim Acta 2022; 1193:338810. [PMID: 35058003 DOI: 10.1016/j.aca.2021.338810] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 06/17/2021] [Accepted: 06/26/2021] [Indexed: 11/01/2022]
Abstract
A thread-based isotachophoresis method coupled with desorption electrospray ionization mass spectrometry (TB-ITP-DESI-MS) was developed and applied for clean-up, preconcentration, and determination of alkaloids in biological fluids. This simple approach enables the focusing and rapid analysis of analytes of interest in complex matrices that are otherwise challenging using direct ambient mass spectrometry. The TB-ITP platform components were rapidly and reproducibly fabricated at low-cost using 3D printing. A single string of nylon 6 thread was used as the electrophoresis substrate and a cotton knot, tied to the nylon thread, was used as the trapping zone of the ITP focused model analytes (coptisine, berberine and palmatine). The trapping efficiency was evaluated upon different commercially available threads with different chemical properties and cotton was selected as the best material due to its highest trapping efficiency and subsequent DESI-MS ionization efficiency. Up to 11.6-fold increase in signal to noise ratio (S/N) was obtained using the proposed method compared to direct DESI-MS detection, due to the reduced matrix interference and focusing. The results demonstrated that the TB-ITP-DESI-MS approach is a viable solution for the analysis of complicated biological fluid samples.
Collapse
Affiliation(s)
- Liang Chen
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia; ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia; ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia
| | - Shing Chung Lam
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia
| | - Estrella Sanz Rodriguez
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia
| | - Peter C Innis
- ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, 7001, Australia; ARC Centre of Excellence for Electromaterials Sciences (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7001, Australia.
| |
Collapse
|
10
|
Swiner DJ, Kulyk DS, Osae H, Durisek GR, Badu-Tawiah AK. Reactive Thread Spray Mass Spectrometry for Localization of C═C Bonds in Free Fatty Acids: Applications for Obesity Diagnosis. Anal Chem 2022; 94:2358-2365. [PMID: 35072466 PMCID: PMC9107611 DOI: 10.1021/acs.analchem.1c03270] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Cellulose thread substrates offer a platform for microsampling and reactive ionization of free fatty acid (FFA) isomers for direct differentiation by mass spectrometry. Ambient corona discharge forms when direct current high voltage is applied to the tiny subfibers on the thread substrate in the presence of a polar spray solvent (MeOH/H2O, 2:1, v/v), facilitating chemical reactions across a C═C bond of unsaturated fatty acids. The process was applied for diagnosis of obesity, which we observed to show better discriminatory power when compared to determinations based on body mass index. Overall, the integrated reactive thread-based platform is capable of (i) microsampling and dry-state, room-temperature storage (>30 days) of the biofluids, (ii) in-capillary liquid/liquid extraction, and (iii) in situ epoxidation reactions to locate the C═C bond position in unsaturated fatty acids via reactions with reactive oxygen species present in ambient corona discharge. The study showcased the ability to correctly characterize FFAs, including degree of unsaturation, and the determination of their relative concentrations in clinical biofluid samples.
Collapse
Affiliation(s)
- Devin J. Swiner
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH 43210, United States
| | - Dmytro S. Kulyk
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH 43210, United States
| | - Hannah Osae
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH 43210, United States
| | - George R. Durisek
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH 43210, United States
| | - Abraham K. Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH 43210, United States
| |
Collapse
|
11
|
Wang Y, Xia B, Deng S, Ye Y, Zhou Y. Performing 2D-1D-2D Mass Spectrometry Imaging Using Strings. Anal Chem 2022; 94:1661-1668. [PMID: 35029371 DOI: 10.1021/acs.analchem.1c04181] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The mass spectrometry imaging (MSI) technique is widely used in several fields due to its ability to provide spatial information of samples. However, for existing MSI methods, the sample is typically placed on a two-dimensional (2D) platform and is scanned back and forth. As a result, the platform size limits the imaging size. This paper proposes a new MSI method that involves the initial imprinting of chemicals on a two-dimensional string plane area. The string plane was then unraveled to a one-dimensional (1D) string, and the chemicals imprinted on it were ionized using a lab-made ion source. Finally, a 2D MSI image was reconstructed through data processing (2D-1D-2D mass imaging). Compared with traditional MSI methods, the imaging size is no longer limited by the platform size, making it possible to perform the MSI of large samples. As proof of concept, this method was used to image an intact seedling of Broussonetia papyrifera. As a result, clear and overall MS images were obtained, demonstrating the ability of this method to analyze large samples.
Collapse
Affiliation(s)
- Yu Wang
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Bing Xia
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China
| | - Shunyan Deng
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ye Ye
- Kunming Institute of Botany, Chinese Academy of Sciences, Kunming, Yunnan 650201, China
| | - Yan Zhou
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, Sichuan 610041, China
| |
Collapse
|
12
|
Jackson S, Badu-Tawiah AK. Enhanced thread spray mass spectrometry: a general method for direct pesticide analysis in various complex matrices. Analyst 2021; 146:5592-5600. [PMID: 34369487 DOI: 10.1039/d1an00651g] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Determination of pesticide residues in a wide variety of matrices is an ongoing challenge due to low concentration and substantial amounts of interfering endogenous compounds that can be coextracted with the analytes. Herein, we describe the use of cellulose thread both as a suitable sampling medium for various matrices and as a direct analysis platform through an improved thread spray mass spectrometry (MS) approach. Enhanced extraction and the subsequent generation of tiny nanodroplets, after the application of DC potential to the wet thread, enabled ultra-sensitive detection of pesticides without prior sample treatment. This methodology was applied to quantify glyphosate and its metabolite, aminomethylphosphonic acid, in surface water at 12.2 μg mL-1 limit of detection (LOD) via standard addition calibration. The method was also used for an internal standard calibration for the analysis of atrazine, which resulted in a LOD of 0.74 ng mL-1. The enhanced thread spray MS platform also proved effective when applied for direct analysis of diphenylamine and thiabendazole, which enabled the evaluation of post-harvest pesticide treatment of fruits (surface and interior) without complete destruction of the fruits.
Collapse
Affiliation(s)
- Sierra Jackson
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH 43210, USA.
| | - Abraham K Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH 43210, USA.
| |
Collapse
|
13
|
Lee S, Chintalapudi K, Badu-Tawiah AK. Clinical Chemistry for Developing Countries: Mass Spectrometry. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2021; 14:437-465. [PMID: 33979544 PMCID: PMC8932337 DOI: 10.1146/annurev-anchem-091520-085936] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Early disease diagnosis is necessary to enable timely interventions. Implementation of this vital task in the developing world is challenging owing to limited resources. Diagnostic approaches developed for resource-limited settings have often involved colorimetric tests (based on immunoassays) due to their low cost. Unfortunately, the performance/sensitivity of such simplistic tests are often limited and significantly hinder opportunities for early disease detection. A new criterion for selecting diagnostic tests in low- and middle-income countries is proposed here that is based on performance-to-cost ratio. For example, modern mass spectrometry (MS) now involves analysis of the native sample in the open laboratory environment, enabling applications in many fields, including clinical research, forensic science, environmental analysis, and agriculture. In this critical review, we summarize recent developments in chemistry that enable MS to be applied effectively in developing countries. In particular, we argue that closed automated analytical systems may not offer the analytical flexibility needed in resource-limited settings. Alternative strategies proposed here have potential to be widely accepted in low- and middle-income countries through the utilization of the open-source ambient MS platform that enables microsampling techniques such as dried blood spot to be coupled with miniature mass spectrometers in a centralized analytical platform. Consequently, costs associated with sample handling and maintenance can be reduced by >50% of the total ownership cost, permitting analytical measurements to be operated at high performance-to-cost ratios in the developing world.
Collapse
Affiliation(s)
- Suji Lee
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, USA;
| | - Kavyasree Chintalapudi
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, USA;
| | - Abraham K Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210, USA;
| |
Collapse
|
14
|
Rankin‐Turner S, Heaney LM. Applications of ambient ionization mass spectrometry in 2020: An annual review. ANALYTICAL SCIENCE ADVANCES 2021; 2:193-212. [PMID: 38716454 PMCID: PMC10989608 DOI: 10.1002/ansa.202000135] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/22/2021] [Accepted: 01/25/2021] [Indexed: 06/26/2024]
Abstract
Recent developments in mass spectrometry (MS) analyses have seen a concerted effort to reduce the complexity of analytical workflows through the simplification (or removal) of sample preparation and the shortening of run-to-run analysis times. Ambient ionization mass spectrometry (AIMS) is an exemplar MS-based technology that has swiftly developed into a popular and powerful tool in analytical science. This increase in interest and demonstrable applications is down to its capacity to enable the rapid analysis of a diverse range of samples, typically in their native state or following a minimalistic sample preparation approach. The field of AIMS is constantly improving and expanding, with developments of powerful and novel techniques, improvements to existing instrumentation, and exciting new applications added with each year that passes. This annual review provides an overview of applications of AIMS techniques over the past year (2020), with a particular focus on the application of AIMS in a number of key fields of research including biomedical sciences, forensics and security, food sciences, the environment, and chemical synthesis. Novel ambient ionization techniques are introduced, including picolitre pressure-probe electrospray ionization and fiber spray ionization, in addition to modifications and improvements to existing techniques such as hand-held devices for ease of use, and USB-powered ion sources for on-site analysis. In all, the information provided in this review supports the view that AIMS has become a leading approach in MS-based analyses and that improvements to existing methods, alongside the development of novel approaches, will continue across the foreseeable future.
Collapse
Affiliation(s)
- Stephanie Rankin‐Turner
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public HealthJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Liam M. Heaney
- School of Sport, Exercise and Health SciencesLoughborough UniversityLoughboroughLeicestershireUK
| |
Collapse
|
15
|
Chen L, Cabot JM, Sanz Rodriguez E, Ghiasvand A, Innis PC, Paull B. Thread-based isoelectric focusing coupled with desorption electrospray ionization mass spectrometry. Analyst 2020; 145:6928-6936. [DOI: 10.1039/d0an01344g] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Efficient ‘on-thread’ isoelectric focusing of proteins, with direct on-thread detection using desorption electrospray ionisation mass spectrometry.
Collapse
Affiliation(s)
- Liang Chen
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Joan M. Cabot
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Estrella Sanz Rodriguez
- Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Peter C. Innis
- ARC Centre of Excellence for Electromaterials Science (ACES)
- AIIM Facility
- Innovation campus
- University of Wollongong
- Australia
| | - Brett Paull
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| |
Collapse
|