1
|
Hayashi A, Hemmi R, Saito Y, Utoh R, Taniguchi T, Yamada M. High-Density Microporous Drainage-Integrating Sheath Flow Generator for Streamlining Microfluidic Cell Sorting Systems. Anal Chem 2024; 96:6764-6773. [PMID: 38619911 DOI: 10.1021/acs.analchem.4c00485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
Tremendous efforts have been made to develop practical and efficient microfluidic cell and particle sorting systems; however, there are technological limitations in terms of system complexity and low operability. Here, we propose a sheath flow generator that can dramatically simplify operational procedures and enhance the usability of microfluidic cell sorters. The device utilizes an embedded polydimethylsiloxane (PDMS) sponge with interconnected micropores, which is in direct contact with microchannels and seamlessly integrated into the microfluidic platform. The high-density micropores on the sponge surface facilitated fluid drainage, and the drained fluid was used as the sheath flow for downstream cell sorting processes. To fabricate the integrated device, a new process for sponge-embedded substrates was developed through the accumulation, incorporation, and dissolution of PMMA microparticles as sacrificial porogens. The effects of the microchannel geometry and flow velocity on the sheath flow generation were investigated. Furthermore, an asymmetric lattice-shaped microchannel network for cell/particle sorting was connected to the sheath flow generator in series, and the sorting performances of model particles, blood cells, and spiked tumor cells were investigated. The sheath flow generation technique developed in this study is expected to streamline conventional microfluidic cell-sorting systems as it dramatically improves versatility and operability.
Collapse
Affiliation(s)
- Ayumi Hayashi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Runa Hemmi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Yuhei Saito
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Rie Utoh
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Tatsuo Taniguchi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Masumi Yamada
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| |
Collapse
|
2
|
Chavez-Pineda OG, Rodriguez-Moncayo R, Gonzalez-Suarez AM, Guevara-Pantoja PE, Maravillas-Montero JL, Garcia-Cordero JL. Portable platform for leukocyte extraction from blood using sheath-free microfluidic DLD. LAB ON A CHIP 2024; 24:2575-2589. [PMID: 38646820 DOI: 10.1039/d4lc00132j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
Leukocyte count is routinely performed for diagnostic purposes and is rapidly emerging as a significant biomarker for a wide array of diseases. Additionally, leukocytes have demonstrated considerable promise in novel cell-based immunotherapies. However, the direct retrieval of leukocytes from whole blood is a significant challenge due to their low abundance compared to erythrocytes. Here, we introduce a microfluidic-based platform that isolates and recovers leukocytes from diluted whole blood in a single step. Our platform utilizes a novel, sheathless method to initially sediment and focus blood cells into a dense stream while flowing through a tubing before entering the microfluidic device. A hexagonal-shaped structure, patterned at the device's inlet, directs all the blood cells against the channel's outer walls. The focused cells are then separated based on their size using the deterministic lateral displacement (DLD) microfluidic technique. We evaluated various parameters that could influence leukocyte separation, including different focusing structures (assessed both computationally and experimentally), the orientation of the tubing-chip interface, the effects of blood sample hematocrit (dilution), and flow rate. Our device demonstrated the ability to isolate leukocytes from diluted blood with a separation efficiency of 100%, a recovery rate of 76%, and a purity of 80%, while maintaining a cell viability of 98%. The device operates for over 30 min at a flow rate of 2 μL min-1. Furthermore, we developed a handheld pressure controller to drive fluid flow, enhancing the operability of our platform outside of central laboratories and enabling near-patient testing. Our platform can be integrated with downstream cell-based assays and analytical methods that require high leukocyte purity (80%), ranging from cell counting to diagnostics and cell culture applications.
Collapse
Affiliation(s)
- Oriana G Chavez-Pineda
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Roberto Rodriguez-Moncayo
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Alan M Gonzalez-Suarez
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Pablo E Guevara-Pantoja
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Jose L Maravillas-Montero
- Red de Apoyo a la Investigación, Universidad Nacional Autónoma de México e Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City14080, Mexico
| | - Jose L Garcia-Cordero
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
- Institute of Human Biology (IHB), Roche Pharma Research and Early Development, Roche Innovation Center Basel, Basel 4058, Switzerland.
| |
Collapse
|
3
|
Zhang T, Di Carlo D, Lim CT, Zhou T, Tian G, Tang T, Shen AQ, Li W, Li M, Yang Y, Goda K, Yan R, Lei C, Hosokawa Y, Yalikun Y. Passive microfluidic devices for cell separation. Biotechnol Adv 2024; 71:108317. [PMID: 38220118 DOI: 10.1016/j.biotechadv.2024.108317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/27/2023] [Accepted: 01/06/2024] [Indexed: 01/16/2024]
Abstract
The separation of specific cell populations is instrumental in gaining insights into cellular processes, elucidating disease mechanisms, and advancing applications in tissue engineering, regenerative medicine, diagnostics, and cell therapies. Microfluidic methods for cell separation have propelled the field forward, benefitting from miniaturization, advanced fabrication technologies, a profound understanding of fluid dynamics governing particle separation mechanisms, and a surge in interdisciplinary investigations focused on diverse applications. Cell separation methodologies can be categorized according to their underlying separation mechanisms. Passive microfluidic separation systems rely on channel structures and fluidic rheology, obviating the necessity for external force fields to facilitate label-free cell separation. These passive approaches offer a compelling combination of cost-effectiveness and scalability when compared to active methods that depend on external fields to manipulate cells. This review delves into the extensive utilization of passive microfluidic techniques for cell separation, encompassing various strategies such as filtration, sedimentation, adhesion-based techniques, pinched flow fractionation (PFF), deterministic lateral displacement (DLD), inertial microfluidics, hydrophoresis, viscoelastic microfluidics, and hybrid microfluidics. Besides, the review provides an in-depth discussion concerning cell types, separation markers, and the commercialization of these technologies. Subsequently, it outlines the current challenges faced in the field and presents a forward-looking perspective on potential future developments. This work hopes to aid in facilitating the dissemination of knowledge in cell separation, guiding future research, and informing practical applications across diverse scientific disciplines.
Collapse
Affiliation(s)
- Tianlong Zhang
- College of Mechanical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212100, China
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA
| | - Chwee Teck Lim
- Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore
| | - Tianyuan Zhou
- College of Mechanical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212100, China
| | - Guizhong Tian
- College of Mechanical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212100, China.
| | - Tao Tang
- Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore
| | - Amy Q Shen
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa 904-0495, Japan
| | - Weihua Li
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Ming Li
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Yang Yang
- Institute of Deep-Sea Science and Engineering, Chinese Academy of Sciences, Sanya, Hainan 572000, China
| | - Keisuke Goda
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA; Department of Chemistry, University of Tokyo, Tokyo 113-0033, Japan; The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
| | - Ruopeng Yan
- The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
| | - Cheng Lei
- The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
| | - Yoichiroh Hosokawa
- Division of Materials Science, Nara Institute of Science and Technology, Nara 630-0192, Japan
| | - Yaxiaer Yalikun
- Division of Materials Science, Nara Institute of Science and Technology, Nara 630-0192, Japan.
| |
Collapse
|
4
|
Kumar T, Harish AV, Etcheverry S, Margulis W, Laurell F, Russom A. Lab-in-a-fiber-based integrated particle separation and counting. LAB ON A CHIP 2023; 23:2286-2293. [PMID: 37070926 DOI: 10.1039/d2lc01175a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
An all-fiber integrated device capable of separating and counting particles is presented. A sequence of silica fiber capillaries with various diameters and longitudinal cavities are used to fabricate the component for size-based elasto-inertial passive separation of particles followed by detection in an uninterrupted continuous flow. Experimentally, fluorescent particles of 1 μm and 10 μm sizes are mixed in a visco-elastic fluid and fed into the all-fiber separation component. The particles are sheathed by an elasticity enhancer (PEO - polyethylene oxide) to the side walls. Larger 10 μm particles migrate to the center of the silica capillary due to the combined inertial lift force and elastic force, while the smaller 1 μm particles are unaffected, and exit from a side capillary. A separation efficiency of 100% for the 10 μm and 97% for the 1 μm particles is achieved at a total flow rate of 50 μL min-1. To the best of our knowledge, this is the first time effective inertial-based separation has been demonstrated in circular cross-section microchannels. In the following step, the separated 10 μm particles are routed through another all-fiber component for counting and a counting throughput of ∼1400 particles per min is demonstrated. We anticipate the ability to combine high throughput separation and precise 3D control of particle position for ease of counting will aid in the development of advanced microflow cytometers capable of particle separation and quantification for various biomedical applications.
Collapse
Affiliation(s)
- T Kumar
- Division of Nanobiotechnology, Department of Protein Science, Science for life laboratory, KTH Royal Institute of Technology, Solna, Sweden.
| | - A V Harish
- Laser Physics, Department of Applied Physics, KTH Royal Institute of Technology, Stockholm, Sweden
| | - S Etcheverry
- Research Institutes of Sweden (RISE), Stockholm, Sweden
| | - W Margulis
- Research Institutes of Sweden (RISE), Stockholm, Sweden
| | - F Laurell
- Laser Physics, Department of Applied Physics, KTH Royal Institute of Technology, Stockholm, Sweden
| | - A Russom
- Division of Nanobiotechnology, Department of Protein Science, Science for life laboratory, KTH Royal Institute of Technology, Solna, Sweden.
- AIMES - Center for the Advancement of Integrated Medical and Engineering Sciences at Karolinska Institutet and KTH Royal Institute of Technology, Stockholm, Sweden
| |
Collapse
|
5
|
Tottori N, Nisisako T. Tunable deterministic lateral displacement of particles flowing through thermo-responsive hydrogel micropillar arrays. Sci Rep 2023; 13:4994. [PMID: 36973401 PMCID: PMC10043002 DOI: 10.1038/s41598-023-32233-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Accepted: 03/24/2023] [Indexed: 03/29/2023] Open
Abstract
Deterministic lateral displacement (DLD) is a promising technology that allows for the continuous and the size-based separation of suspended particles at a high resolution through periodically arrayed micropillars. In conventional DLD, the critical diameter (Dc), which determines the migration mode of a particle of a particular size, is fixed by the device geometry. Here, we propose a novel DLD that uses the pillars of a thermo-responsive hydrogel, poly(N-isopropylacrylamide) (PNIPAM) to flexibly tune the Dc value. Upon heating and cooling, the PNIPAM pillars in the aqueous solution shrink and swell because of their hydrophobic-hydrophilic phase transitions as the temperature varies. Using the PNIPAM pillars confined in a poly(dimethylsiloxane) microchannel, we demonstrate continuous switching of particle (7-μm beads) trajectories (displacement or zigzag mode) by adjusting the Dc through temperature control of the device on a Peltier element. Further, we perform on/off operation of the particle separation (7-μm and 2-μm beads) by adjusting the Dc values.
Collapse
Affiliation(s)
- Naotomo Tottori
- Department of Mechanical Engineering, School of Engineering, Tokyo Institute of Technology, Tokyo, Japan
- Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, Fukuoka, Japan
| | - Takasi Nisisako
- Laboratory for Future Interdisciplinary Research of Science and Technology (FIRST), Institute of Innovative Research, Tokyo Institute of Technology, R2-9, 4259 Nagatsuta-cho, Midori-ku, Yokohama, 226-8503, Japan.
| |
Collapse
|
6
|
Xue S, Xu Q, Xu Z, Zhang X, Zhang H, Zhang X, He F, Chen Y, Xue Y, Hao P. Manipulation of Particle/Cell Based on Compressibility in a Divergent Microchannel by Surface Acoustic Wave. Anal Chem 2023; 95:4282-4290. [PMID: 36815437 DOI: 10.1021/acs.analchem.2c03841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
The mechanical properties (compressibility or deformability) of cells are closely related to their death, migration, and differentiation. Accurate separation and manipulation of bioparticles based on these mechanical properties are still a challenging in the field of acoustofluidics. In this work, based on surface acoustic waves (SAW) and divergent microchannels, we developed a new method for separating and detecting particles or cells with different compressibility. The difference in acoustic radiation force (Fr) caused by compressibility are gradually amplified and accumulated by decreasing the flow velocity, and they are finally reflected in the particle migration distance. During the transverse migration process, the alternating dominance of the acoustic radiation force and the Stokes resistance force (Fs) drives the particles to create three typical migration patterns: intermittent migration, compound migration, and near-wall migration. In the present tilted SAW device, a 91% separation success rate of ∼10 μm polystyrene (PS) and polydimethylsiloxane (PDMS) particles can be achieved by optimizing the acoustic field input power and the fluid velocity. The application potential of the present divergent microchannel is validated by separating the myelogenous leukemia cell K562 and the natural killer cell NK92 that have similar densities and sizes (∼15 μm) but different compressibility. The results of this work are expected to provide valuable insights into the acoustofluidics separation and detection of the cells that are with different compressibility.
Collapse
Affiliation(s)
- Sen Xue
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Qingmei Xu
- School of Integrated Circuits, Peking University, Beijing 100871, China
| | - Zhike Xu
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Xuanhe Zhang
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Haixiang Zhang
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Xiwen Zhang
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Feng He
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Yiqing Chen
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Yu Xue
- School of Medicine & Holistic Integrative Medicine, Nanjing University of Chinese Medicine, Nanjing 210023, China
| | - Pengfei Hao
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
7
|
Maurya A, Murallidharan JS, Sharma A, Agarwal A. Microfluidics geometries involved in effective blood plasma separation. MICROFLUIDICS AND NANOFLUIDICS 2022; 26:73. [PMID: 36090664 PMCID: PMC9440999 DOI: 10.1007/s10404-022-02578-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Accepted: 08/09/2022] [Indexed: 06/15/2023]
Abstract
The last two decades witnessed a significant advancement in the field of diluted and whole blood plasma separation. This is one of the common procedures used to diagnose, cure and treat numerous acute and chronic diseases. For this separation purpose, various types of geometries of microfluidic devices, such as T-channel, Y-channel, trifurcation, constriction-expansion, curved/bend/spiral channels, a combination of any of the two geometries, etc., are being exploited, and this is detailed in this review article. The evaluation of the performance of such devices is based on the several parameters such as separation efficiency, flow rate, hematocrits, channel dimensions, etc. Thus, the current extensive review article endeavours to understand how particular geometry influences the separation efficiency for a given hematocrit. Additionally, a comparative analysis of various geometries is presented to demonstrate the less explored geometric configuration for the diluted and whole blood plasma separation. Also, a meta-analysis has been performed to highlight which geometry serves best to give a consistent separation efficiency. This article also presents tabulated data for various geometries with necessary details required from a designer's perspective such as channel dimensions, targeted component, studied range of hematocrit and flow rate, separation efficiency, etc. The maximum separation efficiency that can be achieved for a given hematocrits and geometry has also been plotted. The current review highlights the critical findings relevant to this field, state of the art understanding and the future challenges.
Collapse
Affiliation(s)
- Anamika Maurya
- Department of Mechanical Engineering, Indian Institute of Technology Mumbai, Mumbai, 400076 India
| | | | - Atul Sharma
- Department of Mechanical Engineering, Indian Institute of Technology Mumbai, Mumbai, 400076 India
| | - Amit Agarwal
- Department of Mechanical Engineering, Indian Institute of Technology Mumbai, Mumbai, 400076 India
| |
Collapse
|
8
|
Inertia-Acoustophoresis Hybrid Microfluidic Device for Rapid and Efficient Cell Separation. SENSORS 2022; 22:s22134709. [PMID: 35808206 PMCID: PMC9268962 DOI: 10.3390/s22134709] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/18/2022] [Accepted: 06/20/2022] [Indexed: 01/07/2023]
Abstract
In this paper, we proposed an integrated microfluidic device that could demonstrate the non-contact, label-free separation of particles and cells through the combination of inertial microfluidics and acoustophoresis. The proposed device integrated two microfluidic chips which were a PDMS channel chip on top of the silicon-based acoustofluidic chip. The PDMS chip worked by prefocusing the particles/cells through inducing the inertial force of the channel structure. The connected acoustofluidic chips separated particles based on their size through an acoustic radiation force. In the serpentine-shaped PDMS chip, particles formed two lines focusing in the channel, and a trifugal-shaped acoustofluidic chip displaced and separated particles, in which larger particles focused on the central channel and smaller ones moved to the side channels. The simultaneous fluidic works allowed high-efficiency particle separation. Using this novel acoustofluidic device with an inertial microchannel, the separation of particles and cells based on their size was presented and analyzed, and the efficiency of the device was shown. The device demonstrated excellent separation performance with a high recovery ratio (up to 96.3%), separation efficiency (up to 99%), and high volume rate (>100 µL/min). Our results showed that integrated devices could be a viable alternative to current cell separation based on their low cost, reduced sample consumption and high throughput capability.
Collapse
|
9
|
Ji M, Liu Y, Duan J, Zang W, Wang Y, Qu Z, Zhang B. A Novel Perturbed Spiral Sheathless Chip for Particle Separation Based on Traveling Surface Acoustic Waves (TSAW). BIOSENSORS 2022; 12:bios12050325. [PMID: 35624627 PMCID: PMC9138558 DOI: 10.3390/bios12050325] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 05/07/2022] [Accepted: 05/10/2022] [Indexed: 06/01/2023]
Abstract
The combination of the new perturbed spiral channel and a slanted gold interfingered transducer (IDT) is designed to achieve precise dynamic separation of target particles (20 μm). The offset micropillar array solves the defect that the high-width flow (avoiding the occurrence of channel blockage) channel cannot realize the focusing of small particles (5 μm, 10 μm). The relationship between the maximum design gap of the micropillar (Smax) and the particle radius (a) is given: Smax = 4a, which not only ensures that small particles will not pass through the micropillar gap, but also is compatible with the appropriate flow rates. A non-offset micropillar array was used to remove 20 μm particles in the corner area. The innovation of a spiral channel structure greatly improves the separation efficiency and purity of the separation chip. The separation chip designed by us achieves deflection separation of 20 μm particles at 24.95-41.58 MHz (κ = 1.09-1.81), at a flow rate of 1.2 mL per hour. When f = 33.7 MHz (κ = 1.47), the transverse migration distance of 20 μm particles is the smallest, and the separation purity and efficiency are as high as 92% and 100%, respectively.
Collapse
Affiliation(s)
- Miaomiao Ji
- Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China; (M.J.); (J.D.); (W.Z.); (Y.W.); (Z.Q.)
| | - Yukai Liu
- Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China;
| | - Junping Duan
- Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China; (M.J.); (J.D.); (W.Z.); (Y.W.); (Z.Q.)
| | - Wenxuan Zang
- Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China; (M.J.); (J.D.); (W.Z.); (Y.W.); (Z.Q.)
| | - Yongsheng Wang
- Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China; (M.J.); (J.D.); (W.Z.); (Y.W.); (Z.Q.)
| | - Zeng Qu
- Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China; (M.J.); (J.D.); (W.Z.); (Y.W.); (Z.Q.)
| | - Binzhen Zhang
- Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030051, China; (M.J.); (J.D.); (W.Z.); (Y.W.); (Z.Q.)
| |
Collapse
|
10
|
Rapid and efficient capturing of circulating tumor cells from breast cancer Patient's whole blood via the antibody functionalized microfluidic (AFM) chip. Biosens Bioelectron 2022; 201:113965. [PMID: 35016111 DOI: 10.1016/j.bios.2022.113965] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 11/29/2021] [Accepted: 01/03/2022] [Indexed: 12/20/2022]
Abstract
Accurate enumeration of circulating tumor cells (CTCs) in cancer patient's blood functions as a form of "liquid biopsy", which is pivotal for cancer screening, prognosis, and diagnosis. Herein, we demonstrate a novel antibody functionalized microfluidic (AFM) chip that rapidly and accurately qualifies CTCs from breast cancer patient's whole blood. The AFM chip consists of three buffering zones, and four main capturing zones filled with equilateral triangular pillars and periodically distributed obstacles. We validate the AFM chip with three Epithelial cell adhesion molecule (EpCAM) positive cancer cell lines, including breast (MCF-7), prostate (PC3), and lung cancer cell lines (A549), achieving capture efficiencies of 99.5%, 98.5%, and 96.72%, respectively, at a flow rate of 0.6 mL/hour. We further confirm the efficacy of the AFM chip with five advanced breast cancer patients' whole blood to capture EpCAM+/CK19+/CD45-/DAPI + CTCs. Interestingly, high number of CTCs were identified from each patient's 1 mL whole blood (595-2270), The AFM chip is highly efficient at rapidly capturing CTCs from cancer patients' whole blood without requiring extra equipment, which is critically beneficial for clinical application.
Collapse
|
11
|
Tang H, Niu J, Jin H, Lin S, Cui D. Geometric structure design of passive label-free microfluidic systems for biological micro-object separation. MICROSYSTEMS & NANOENGINEERING 2022; 8:62. [PMID: 35685963 PMCID: PMC9170746 DOI: 10.1038/s41378-022-00386-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/27/2022] [Accepted: 03/18/2022] [Indexed: 05/05/2023]
Abstract
Passive and label-free microfluidic devices have no complex external accessories or detection-interfering label particles. These devices are now widely used in medical and bioresearch applications, including cell focusing and cell separation. Geometric structure plays the most essential role when designing a passive and label-free microfluidic chip. An exquisitely designed geometric structure can change particle trajectories and improve chip performance. However, the geometric design principles of passive and label-free microfluidics have not been comprehensively acknowledged. Here, we review the geometric innovations of several microfluidic schemes, including deterministic lateral displacement (DLD), inertial microfluidics (IMF), and viscoelastic microfluidics (VEM), and summarize the most creative innovations and design principles of passive and label-free microfluidics. We aim to provide a guideline for researchers who have an interest in geometric innovations of passive label-free microfluidics.
Collapse
Affiliation(s)
- Hao Tang
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent Diagnosis and Treatment Instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan RD, Shanghai, 200240 China
| | - Jiaqi Niu
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent Diagnosis and Treatment Instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan RD, Shanghai, 200240 China
| | - Han Jin
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent Diagnosis and Treatment Instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan RD, Shanghai, 200240 China
- National Engineering Research Center for Nanotechnology, Shanghai Jiao Tong University, 28 Jiangchuan Easternroad, Shanghai, 200241 China
| | - Shujing Lin
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent Diagnosis and Treatment Instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan RD, Shanghai, 200240 China
- National Engineering Research Center for Nanotechnology, Shanghai Jiao Tong University, 28 Jiangchuan Easternroad, Shanghai, 200241 China
| | - Daxiang Cui
- Institute of Nano Biomedicine and Engineering, Shanghai Engineering Research Center for Intelligent Diagnosis and Treatment Instrument, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan RD, Shanghai, 200240 China
- National Engineering Research Center for Nanotechnology, Shanghai Jiao Tong University, 28 Jiangchuan Easternroad, Shanghai, 200241 China
| |
Collapse
|
12
|
Rahmati M, Chen X. Separation of circulating tumor cells from blood using dielectrophoretic DLD manipulation. Biomed Microdevices 2021; 23:49. [PMID: 34581876 DOI: 10.1007/s10544-021-00587-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/17/2021] [Indexed: 11/26/2022]
Abstract
Circulating Tumor Cells (CTCs) play a prominent role in early cancer detection. Emerging label-free techniques can be promising to CTC detection due to advantages in preserving cell integrity and minimal sample consumption. Deterministic Lateral Displacement (DLD) is a size-based label-free technique employing laminar flow for continuous sorting of suspended cells. However, separation based solely on size is challenging as the size distributions of CTCs tend to overlap with blood cells. Moreover, the rarity of CTCs in blood requires high throughput processing of samples for clinical utility. In this work, a dielectrophoretic DLD technique is presented to segregate CTCs from blood. This technique utilizes the cell size and dielectric properties as well as particle movement caused by polarization effect to accomplish continuous separation at high flow rates. A numerical model is developed and validated to investigate the effects of various parameters related to the fluid flow, micro-post array, and electric field. It is demonstrated that the dielectrophoretic DLD with specific post arrangement can continuously separate A549 lung CTCs from WBCs by applying a field frequency close to the crossover frequency of CTCs. The analysis further indicates that such a device can perform well despite uncertainties of CTC crossover frequencies. Additionally, efficient separation with minimum clogging can be achieved by setting the electric field perpendicular to fluid flow. The presented platform offers distinct advantages and can be potentially combined with techniques such as antibody-based immune-binding methods for rapid detection of CTCs.
Collapse
Affiliation(s)
- Mehdi Rahmati
- School of Engineering and Computer Science, Washington State University, Vancouver, WA, 98686, USA
| | - Xiaolin Chen
- School of Engineering and Computer Science, Washington State University, Vancouver, WA, 98686, USA.
| |
Collapse
|
13
|
Han BH, Kim S, Seo G, Heo Y, Chung S, Kang JY. Isolation of extracellular vesicles from small volumes of plasma using a microfluidic aqueous two-phase system. LAB ON A CHIP 2020; 20:3552-3559. [PMID: 32808641 DOI: 10.1039/d0lc00345j] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
As conventional bulky methods for extracellular vesicle (EV) separation are unsuitable for small volumes of samples, microfluidic devices are thought to offer a solution for the integrated and automatic processing of EV separation. This study demonstrates a simple microfluidic aqueous two-phase system (ATPS) for EV separation with high recovery efficiency to overcome the limitation of previous devices, which require complex external equipment or high cost manufacturing. With polyethylene glycol and dextran in the microfluidic channel, the isolation mechanism of the microfluidic ATPS was analyzed by comparison between two-phase and one-phase systems. Our device could facilitate continuous EV isolation with 83.4% recovery efficiency and remove 65.4% of the proteins from the EV-protein mixture. EVs were also successfully isolated from human plasma at high recovery efficiency.
Collapse
Affiliation(s)
- Bo Hoon Han
- Center for BioMicrosystems, Korea Institute of Science and Technology, Seoul, Republic of Korea. and School of Mechanical Engineering, Korea University, Seoul, Korea
| | - Sumi Kim
- Center for BioMicrosystems, Korea Institute of Science and Technology, Seoul, Republic of Korea.
| | - Geeyoon Seo
- Center for BioMicrosystems, Korea Institute of Science and Technology, Seoul, Republic of Korea.
| | - Youhee Heo
- Center for BioMicrosystems, Korea Institute of Science and Technology, Seoul, Republic of Korea. and Department of Biomedical Engineering, Sogang University, Seoul, Korea
| | - Seok Chung
- School of Mechanical Engineering, Korea University, Seoul, Korea and KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul, Korea
| | - Ji Yoon Kang
- Center for BioMicrosystems, Korea Institute of Science and Technology, Seoul, Republic of Korea. and Division of Bio-Medical Science & Technology (UST), Korea Institute of Science and Technology School, Seoul, Korea
| |
Collapse
|