1
|
Mishra A, Goel D, Shankar S. Bisphenol A contamination in aquatic environments: a review of sources, environmental concerns, and microbial remediation. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:1352. [PMID: 37861868 DOI: 10.1007/s10661-023-11977-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 10/09/2023] [Indexed: 10/21/2023]
Abstract
The production of polycarbonate, a high-performance transparent plastic, employs bisphenol A, which is a prominent endocrine-disrupting compound. Polycarbonates are frequently used in the manufacturing of food, bottles, storage containers for newborns, and beverage packaging materials. Global production of BPA in 2022 was estimated to be in the region of 10 million tonnes. About 65-70% of all bisphenol A is used to make polycarbonate plastics. Bisphenol A leaches from improperly disposed plastic items and enters the environment through wastewater from plastic-producing industries, contaminating, sediments, surface water, and ground water. The concentration BPA in industrial and domestic wastewater ranges from 16 to 1465 ng/L while in surface water it has been detected 170-3113 ng/L. Wastewater treatment can be highly effective at removing BPA, giving reductions of 91-98%. Regardless, the remaining 2-9% of BPA will continue through to the environment, with low levels of BPA commonly observed in surface water and sediment in the USA and Europe. The health effects of BPA have been the subject of prolonged public and scientific debate, with PubMed listing more than 17,000 scientific papers as of 2023. Bisphenol A poses environmental and health hazards in aquatic systems, affecting ecosystems and human health. While several studies have revealed its presence in aqueous streams, environmentally sound technologies should be explored for its removal from the contaminated environment. Concern is mostly related to its estrogen-like activity, although it can interact with other receptor systems as an endocrine-disrupting chemical. Present review article encompasses the updated information on sources, environmental concerns, and sustainable remediation techniques for bisphenol A removal from aquatic ecosystems, discussing gaps, constraints, and future research requirements.
Collapse
Affiliation(s)
- Anuradha Mishra
- Department of Applied Chemistry, School of Vocational Studies and Applied Sciences (SoVSAS), Gautam Buddha University (GBU), Govt. of Uttar Pradesh, Greater Noida, Uttar Pradesh, 201 312, India
| | - Divya Goel
- Department of Environmental Science, School of Vocational Studies and Applied Sciences (SoVSAS), Gautam Buddha University (GBU), Govt. of Uttar Pradesh, Greater Noida, Uttar Pradesh, 201 312, India
| | - Shiv Shankar
- Department of Environmental Science, School of Vocational Studies and Applied Sciences (SoVSAS), Gautam Buddha University (GBU), Govt. of Uttar Pradesh, Greater Noida, Uttar Pradesh, 201 312, India.
| |
Collapse
|
2
|
Nguyen MB, Anh NH, Thi Thu V, Thi Hai Yen P, Hong Phong P, Quoc Hung L, Ngan NTT, Hai TQ, Thi Thu Ha V. A novel bimetallic MOFs combined with gold nanoflakes in electrochemical sensor for measuring bisphenol A. RSC Adv 2022; 12:33825-33834. [PMID: 36505679 PMCID: PMC9693748 DOI: 10.1039/d2ra06300j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Accepted: 11/16/2022] [Indexed: 11/27/2022] Open
Abstract
In this paper, a novel bimetallic Fe-Cu metal-organic framework combined with 1,3,5-benzenetricarboxylic acid (Fe-Cu-BTC) are synthesized using hydrothermal reaction. The bimetallic Fe-Cu-BTC with high BET (1504 cm3 g-1) and high Langmuir surface area (1831 cm3 g-1) is composited by gold nanoparticles to improve the conductivity and to develop their synergistic effect. A novel bisphenol A (BPA) sensor was prepared by dropcasting Fe-Cu-BTC on glassy carbon electrodes (GCE) followed by AuNPs electrodeposition. The Fe-Cu-BTC framework were characterized by X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy studies (TEM), FT-IR, BET measurements and EDX spectra. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were carried out for surveying the electrochemical properties of the sensors and for the quantification of BPA. Two linear ranges of BPA concentrations 0.1-1.0 μM and 1.0-18 μM with 18 nM limit of detection were obtained. The developed sensor was used to measure the concentration of BPA in samples extracted from rain coat with the recovery ranging from 85.70 to 103.23%.
Collapse
Affiliation(s)
- Manh B. Nguyen
- Institute of Chemistry, Vietnam Academy of Science and Technology18 Hoang Quoc Viet Street, Cau Giay DistrictHanoiVietnam
| | - Nguyen Hai Anh
- Hanoi University of Industry298 Cau Dien Street, Bac Tu Liem DistrictHanoiVietnam
| | - Vu Thi Thu
- University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology18 Hoang Quoc Viet Street, Cau Giay DistrictHanoiVietnam
| | - Pham Thi Hai Yen
- Institute of Chemistry, Vietnam Academy of Science and Technology18 Hoang Quoc Viet Street, Cau Giay DistrictHanoiVietnam
| | - Pham Hong Phong
- Institute of Chemistry, Vietnam Academy of Science and Technology18 Hoang Quoc Viet Street, Cau Giay DistrictHanoiVietnam
| | - Le Quoc Hung
- Institute of Chemistry, Vietnam Academy of Science and Technology18 Hoang Quoc Viet Street, Cau Giay DistrictHanoiVietnam
| | - Nguyen Thi Thanh Ngan
- University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology18 Hoang Quoc Viet Street, Cau Giay DistrictHanoiVietnam
| | - Tran Quang Hai
- Hanoi University of Industry298 Cau Dien Street, Bac Tu Liem DistrictHanoiVietnam
| | - Vu Thi Thu Ha
- Institute of Chemistry, Vietnam Academy of Science and Technology18 Hoang Quoc Viet Street, Cau Giay DistrictHanoiVietnam
| |
Collapse
|
3
|
Zhou Y, She X, Wu Q, Xiao J, Peng T. Monoclinic WO3 nanosheets-carbon nanotubes nanocomposite based electrochemical sensor for sensitive detection of bisphenol A. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116355] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
4
|
Zhao F, Yao X, Liu C, Ran X, Wang C, Lu B. Mercapto-functionalized ordered mesoporous silica-modified PVDF membrane for efficiently scavenging Cd 2+ from water. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 302:114103. [PMID: 34798586 DOI: 10.1016/j.jenvman.2021.114103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 10/01/2021] [Accepted: 11/11/2021] [Indexed: 06/13/2023]
Abstract
In this study, (3-mercaptopropyl) triethoxysilane (MPTMS)-modified ordered mesoporous silica (OMS) materials were prepared using a post-grifting method, with MPTMS as the organic functionalized reagent. The OMS materials were analyzed by FT-IR spectra, N2 sorption, and small angle X-ray scattering to evaluate their potential for scavenging Cd2+ from water. Moreover, a (3-mercaptopropyl) triethoxysilane-functionalized ordered mesoporous silica modified polyvinylidene fluoride (MPTMS-OMS/PVDF) membrane was synthesized using the solvent phase inversion method to remediate wastewater containing heavy metal ions. The MPTMS-OMS was characterized by a maximum specific surface area of 422 m2/g, high surface hydrophilicity, and high pure water flux. The MPTMS-OMS/PVDF exhibited a dynamic adsorption capacity for Cd2+ in water. At an MPTMS-OMS content of 5 wt%, the Cd2+ removal efficiency was 90%, whereas the pure PVDF showed no Cd2+ adsorption capacity. These results highlight the potential of the MPTMS-OMS/PVDF membrane to eliminate Cd2+ during the decontamination of aqueous streams containing low-concentrations of contaminants.
Collapse
Affiliation(s)
- Fengbin Zhao
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai, 200092, China
| | - Xinyun Yao
- School of Chemistry and Molecular Engineering, East China University of Science and Technology, 130 Meilong Road, Shanghai, 20037, China
| | - Chang Liu
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai, 200092, China
| | - Xianqiang Ran
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai, 200092, China
| | - Chengxian Wang
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai, 200092, China
| | - Bin Lu
- State Key Laboratory of Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai, 200092, China.
| |
Collapse
|
5
|
Jemmeli D, Dridi C, Abbas MN, Dempsey E. Development of highly sensitive and selective bisphenol A sensor based on a cobalt phthalocyanine-modified carbon paste electrode: application in dairy analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4674-4682. [PMID: 34549730 DOI: 10.1039/d1ay00827g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The development of an accurate, sensitive and selective sensor for the detection of bisphenol A (BPA) based on the incorporation of a new phthalocyanine derivative, cobalt phthalocyanine, C,C,C,C-tetracarboxylic acid-polyacrylamide (CoPc-PAA) into a carbon-paste matrix is presented using voltammetry and constant potential techniques. The influence of measuring parameters such as pH and scan rate on the analytical performance of the sensor was evaluated. Several kinetic parameters such as electron transfer number (n), charge transfer coefficient (α), electrode surface area (A) and diffusion coefficient (D) were also calculated. Under optimum conditions, particularly at pH 7.2, the BPA sensor resulted in a wide linear range from 25 × 10-11 M to 2.5 × 10-7 M and a limit of detection as low as 63.5 pM. Based on these findings, it can be concluded that our sensor can be substantially utilized for detecting BPA in spiked milk samples.
Collapse
Affiliation(s)
- Dhouha Jemmeli
- NANOMISENE Laboratory LR16CRMN01, Center of Research on Microelectronics and Nanotechnology (CRMN), Sousse Technopole, Tunisia.
| | - Chérif Dridi
- NANOMISENE Laboratory LR16CRMN01, Center of Research on Microelectronics and Nanotechnology (CRMN), Sousse Technopole, Tunisia.
| | - Mohammed N Abbas
- Analytical Laboratory, Department of Applied Organic Chemistry Polymer and Pigments Department, National Research Centre, Cairo, Egypt
| | - Eithne Dempsey
- Kathleen Lonsdale Institute for Human Health Research, Department of Chemistry, Maynooth University, Maynooth, Co. Kildare, Ireland
| |
Collapse
|
6
|
Raysyan A, Schneider RJ. Development of a Lateral Flow Immunoassay (LFIA) to Screen for the Release of the Endocrine Disruptor Bisphenol A from Polymer Materials and Products. BIOSENSORS 2021; 11:231. [PMID: 34356704 PMCID: PMC8301804 DOI: 10.3390/bios11070231] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 07/06/2021] [Accepted: 07/06/2021] [Indexed: 02/01/2023]
Abstract
One of the most important chemicals used in the production of polymer plastics and coatings is bisphenol A. However, despite the large number of studies on the toxicity and hormonal activity of BPA, there are still open questions and thus considerable media attention regarding BPA toxicity. Hence, it is necessary to develop a sensitive, simple, cost-efficient, specific, portable, and rapid method for monitoring bisphenol A and for high sample throughput and on-site screening analysis. Lateral flow immunoassays have potential as rapid tests for on-site screening. To meet sensitivity criteria, they must be carefully optimized. A latex microparticle-based LFIA for detection of BPA was developed. The sensitivity of the assay was improved by non-contact printing of spot grids as the control and test lines with careful parameter optimization. Results of the test could be visually evaluated within 10 min with a visual cut-off of 10 µg/L (vLOD). Alternatively, photographs were taken, and image analysis performed to set up a calibration, which allowed for a calculated limit of detection (cLOD) of 0.14 µg/L. The method was validated for thermal paper samples against ELISA and LC-MS/MS as reference methods, showing good agreement with both methods.
Collapse
Affiliation(s)
- Anna Raysyan
- BAM Federal Institute for Materials Research and Testing, 12205 Berlin, Germany;
- Department of Chemistry, Humboldt-Universität zu Berlin, 12489 Berlin, Germany
| | - Rudolf J. Schneider
- BAM Federal Institute for Materials Research and Testing, 12205 Berlin, Germany;
- Faculty III Process Sciences, Technische Universität Berlin, 10623 Berlin, Germany
| |
Collapse
|