1
|
Gutiérrez A, Ramírez-Ledesma MG, Rivas GA, Luna-Bárcenas G, Escalona-Villalpando RA, Ledesma-García J. Development of an electrochemical sensor for the quantification of ascorbic acid and acetaminophen in pharmaceutical samples. J Pharm Biomed Anal 2024; 249:116334. [PMID: 38976964 DOI: 10.1016/j.jpba.2024.116334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 07/01/2024] [Accepted: 07/02/2024] [Indexed: 07/10/2024]
Abstract
This work presents the modification of glassy carbon electrodes (GCE) by using a dispersion resulting from the non-covalent functionalization of multi-walled carbon nanotubes (MWCNT) with polyarginine (polyArg). MWCNT-polyArg is used for the quantification of ascorbic acid (AA) in the presence of acetaminophen (APAP) and viceversa. Since ascorbic acid and acetaminophen are strongly absorbed on GCE/MWCNT-polyArg, they can be detected in the presence of 4.0×10-5 M acetaminophen (and 3.0×10-5 M ascorbic acid) by using adsorptive stripping with media exchange and differential pulse voltammetry. Using water as the solvent for the MWCNT dispersion, the result was Z-potential of 0.053 ± 0.006 V. The developed sensor showed excellent specificity, sensitivity, stability and reproducibility compared to previously published sensors. The GCE/MWCNT-polyArg sensor shows a fast response time of ∼5 minutes, low limits of detection and quantification for AA (0.95 and 2.9 μM respectively) and APAP (0.27 and 0.82μM, respectively), high sensitivity of 0.0616 μA/M for AA or APAP 0.240μA/M. It was used to test its practicability by determining the concentration of AA or APAP (AA and APAP) in pharmaceutical samples. Finally, the simultaneous measurement of ascorbic acid and acetaminophen in pharmaceuticals showed a good correlation, with a maximum error and RSD of 4.5 and 5.1 %, respectively.
Collapse
Affiliation(s)
- Alejandro Gutiérrez
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico; CONAHCYT, Consejo Nacional de Humanidades, Ciencias y Tecnologías, Av. Insurgentes Sur 1582, Col. Crédito Constructor, Benito Juárez, Ciudad de México 03940, Mexico.
| | - María Guadalupe Ramírez-Ledesma
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico
| | - Gustavo A Rivas
- INFIQC, Departamento de Físico Química, Facultad de Ciencias Químicas, Universidad Nacional de Córdoba, Córdoba 5000, Argentina
| | - Gabriel Luna-Bárcenas
- Tecnológico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Santiago de Querétaro 76130, Mexico
| | - Ricardo A Escalona-Villalpando
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico
| | - Janet Ledesma-García
- División de Investigación y Posgrado, Facultad de Ingeniería, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico.
| |
Collapse
|
2
|
Li Z, Chen F, Zhu N, Zhang L, Xie Z. Tip-Enhanced Sub-Femtomolar Steroid Immunosensing via Micropyramidal Flexible Conducting Polymer Electrodes for At-Home Monitoring of Salivary Sex Hormones. ACS NANO 2023; 17:21935-21946. [PMID: 37922489 DOI: 10.1021/acsnano.3c08315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2023]
Abstract
Noninvasive testing and continuous monitoring of ultralow-concentration hormones in biofluids have attracted increasing interest for health management and personalized medicine, in which saliva could fulfill the demand. Steroid sex hormones such as progesterone (P4) and β-estradiol (E2) are crucial for female wellness and reproduction; however, their concentrations in saliva can vary down to sub-pM and constantly fluctuate over several orders of magnitude. This remains a major obstacle toward user-friendly and reliable monitoring at home with low-cost flexible biosensors. Herein we introduce a 3D micropyramidal electrode architecture to address such challenges and achieve an ultrasensitive flexible electrochemical immunosensor with sub-fM-level detection capability of salivary sex hormones within a few minutes. This is enabled by micropyramidal electrode arrays consisting of a poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) thin film as the coating layer and electrochemically decorated gold nanoparticles (AuNPs) to improve the antibody immobilization. The enhanced mass transport around the 3D tips provided by the micropyramidal architecture is discovered to improve the detection limit by 3 orders of magnitude, pushing it to as low as ∼100 aM for P4 and ∼20 aM for E2, along with a wide linear range up to μM. Accordingly, these hormones down to sub-fM in >1000-fold-diluted saliva samples can be accurately measured by the printed soft immunosensors, thus allowing at-home testing through simple saliva dilution to minimize the interfering substances instead of centrifugation. Finally, monitoring of the female ovarian hormone cycle of both P4 and E2 is successfully demonstrated based on the centrifuge-free saliva testing during a period of 4 weeks. This ultrasensitive and soft 3D microarchitected electrode design is believed to provide a universal platform for a diverse variety of applications spanning from accurate clinical diagnostics and counselling and in vivo detection of bioactive species to environmental and food quality tracing.
Collapse
Affiliation(s)
- Zhaoxian Li
- School of Materials Science and Engineering, and Key Laboratory for Polymeric Composite and Functional Materials of Ministry of Education, Sun Yat-sen University, Guangzhou, 510006, People's Republic of China
| | - Fubin Chen
- School of Materials Science and Engineering, and Key Laboratory for Polymeric Composite and Functional Materials of Ministry of Education, Sun Yat-sen University, Guangzhou, 510006, People's Republic of China
| | - Nan Zhu
- Zhang Dayu School of Chemistry, Dalian University of Technology, Dalian, 116024, People's Republic of China
| | - Limei Zhang
- Reproductive Medicine Center, Department of Obstetrics and Gynecology, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, 510080, People's Republic of China
| | - Zhuang Xie
- School of Materials Science and Engineering, and Key Laboratory for Polymeric Composite and Functional Materials of Ministry of Education, Sun Yat-sen University, Guangzhou, 510006, People's Republic of China
| |
Collapse
|
3
|
Cai Q, Jin S, Zong H, Pei L, Cao K, Qu L, Li Z. A Quadruplex Ultrasensitive Immunoassay for Simultaneous Assessment of Human Reproductive Hormone Proteins in Multiple Biofluid Samples. Anal Chem 2023; 95:11641-11648. [PMID: 37489999 DOI: 10.1021/acs.analchem.3c01399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/26/2023]
Abstract
Reproductive hormones play vital roles in reproductive health and can be used to assess a woman's ovarian function and diagnose diseases associated with reproductive endocrine disorders. As these hormones are important biomarkers for reproductive health monitoring and diagnosis, a rapid, high-throughput, and low-invasive detection and simultaneous assessment of the levels of multiple reproductive hormones has important clinical applications. In this work, a quadruplex ultrasensitive immunoassay was developed for simultaneous assessment of 4 human reproductive hormone proteins (follicle-stimulating hormone (FSH), luteinizing hormone (LH), prolactin (PRL), and anti-Müllerian hormone (AMH)) in a variety of human biofluid samples. This assay takes advantage of single-molecule imaging of microwell arrays and capture antibody beads as a reaction interface to construct multiplex bead array immunoassays. The analyte-bound beads can easily be parsed to individual wells and detected via fluorophores, emitting distinct wavelengths associated to the beads. As a result, this proposed quadruplex immunoassay exhibits four good 4-parameter logistic calibration curves ranging from 2.7 to 2000, 1.6 to 1200, 1.8 to 1300, and 0.3 to 220 pg/mL with limits of detection of 0.32, 0.28, 0.14, and 0.02 pg/mL for FSH, LH, PRL, and AMH, respectively. Furthermore, the developed quadruplex immunoassay was used to test clinical venous serum samples where it showed remarkable consistency with clinical test results in methodological comparison and the diagnosis of polycystic ovary syndrome. In addition, we successfully applied the ultrasensitive capability of this assay to the simultaneous testing and evaluation of four proteins in fingertip blood as well as urine samples, in which the urinary AMH level (1.42-156 pg/mL) was measured and assessed quantitatively for the first time.
Collapse
Affiliation(s)
- Qiyong Cai
- Institute of Chemical Biology and Clinical Application at the First Affiliated Hospital, Zhengzhou University, Zhengzhou 450001, People's Republic of China
- College of Chemistry, Institute of Analytical Chemistry for Life Science, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, People's Republic of China
| | - Shuiling Jin
- Institute of Chemical Biology and Clinical Application at the First Affiliated Hospital, Zhengzhou University, Zhengzhou 450001, People's Republic of China
- Department of Oncology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, People's Republic of China
| | - Hong Zong
- Institute of Chemical Biology and Clinical Application at the First Affiliated Hospital, Zhengzhou University, Zhengzhou 450001, People's Republic of China
- Department of Oncology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, People's Republic of China
| | - Lu Pei
- Department of Laboratory Medicine, Zhengzhou Hospital of Traditional Chinese Medicine, Zhengzhou 450006, People's Republic of China
| | - Ke Cao
- Department of Laboratory Medicine, Zhengzhou Hospital of Traditional Chinese Medicine, Zhengzhou 450006, People's Republic of China
| | - Lingbo Qu
- Institute of Chemical Biology and Clinical Application at the First Affiliated Hospital, Zhengzhou University, Zhengzhou 450001, People's Republic of China
- College of Chemistry, Institute of Analytical Chemistry for Life Science, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, People's Republic of China
| | - Zhaohui Li
- Institute of Chemical Biology and Clinical Application at the First Affiliated Hospital, Zhengzhou University, Zhengzhou 450001, People's Republic of China
- College of Chemistry, Institute of Analytical Chemistry for Life Science, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Zhengzhou Key Laboratory of Functional Nanomaterial and Medical Theranostic, Zhengzhou University, Zhengzhou 450001, People's Republic of China
| |
Collapse
|
4
|
Lu X, Ye Y, Wang Y, Xu J, Sun J, Ji J, Zhang Y, Sun X. Rapid generation of high-quality recombinant antibodies using an Expi293F expression system for a 17 β-estradiol immunoassay. JOURNAL OF HAZARDOUS MATERIALS 2023; 451:131126. [PMID: 36878029 DOI: 10.1016/j.jhazmat.2023.131126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 02/26/2023] [Accepted: 03/01/2023] [Indexed: 06/18/2023]
Abstract
The rapid generation of high-quality target antibodies is essential for research employing immunoassays. The use of recombinant antibody technology that relies on genetic engineering is one such means to produce high-quality antibodies. Obtaining the gene sequence information of immunoglobulin is a prerequisite for the preparation of genetically engineered antibodies. At present, many researchers have shared their amino acid sequence data for various high-performance antibodies and their related properties. In this study, we obtained the protein sequence of a variable region of a 17 β-estradiol (E2) antibody from the Protein Data Bank (PDB) and subsequently constructed heavy (H) and light (L) chain expression vectors through codon optimization. The transient expression, purification, and performance identification of the immunoglobulin G (IgG), antigen-binding fragment (Fab), and single-chain variable fragment (scFv) antibodies were carried out, respectively. The effects of the different expression vectors on the expression yield of the IgG antibody were further compared. Among them, the expression yield based on the pTT5 vector was the highest, reaching 27 mg/L. Based on the expressed IgG and Fab antibodies, an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) standard curve of E2 was constructed, and the half-maximal inhibitory concentrations (IC50) for these two antibodies were determined to be 0.129 ng/mL and 0.188 ng/mL, respectively. In addition, an immunochromatographic assay (ICA) based on the IgG antibody was constructed with an IC50 of 3.7 ng/mL. Therefore, in featuring the advantages of simplicity, high efficiency, rapid obtainment, and high titer yield, we propose the system for the rapid generation of high-quality recombinant antibodies by reusing the published antibody information and show that it has good implementation prospects in improving upon existing immunoassay techniques.
Collapse
Affiliation(s)
- Xin Lu
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Yongli Ye
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Yunyun Wang
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Jia Xu
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Jiadi Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Jian Ji
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Yinzhi Zhang
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 214122, PR China
| | - Xiulan Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Nutrition, Jiangnan University, Wuxi, Jiangsu 214122, PR China.
| |
Collapse
|
5
|
Arévalo B, Serafín V, Garranzo-Asensio M, Montero-Calle A, Barderas R, Yáñez-Sedeño P, Campuzano S, Pingarrón JM. Anti-double stranded DNA antibodies: Electrochemical isotyping in autoimmune and neurological diseases. Anal Chim Acta 2023; 1257:341153. [PMID: 37062567 DOI: 10.1016/j.aca.2023.341153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/21/2023] [Accepted: 03/27/2023] [Indexed: 04/18/2023]
Abstract
This work reports the first amperometric biosensor for the simultaneous determination of the single or total content of the most relevant human immunoglobulin isotypes (hIgs) of anti-dsDNA antibodies, dsDNA-hIgG, dsDNA-hIgM, dsDNA-hIgA and dsDNA-three hIgs, which are considered relevant biomarkers in prevalent autoimmune diseases such as systemic lupus erythematosus (SLE) as well as of interest in neurodegenerative diseases such as Alzheimer's disease (AD). The bioplatform involves the use of neutravidin-functionalized magnetic microparticles (NA-MBs) modified with a laboratory-prepared biotinylated human double-stranded DNA (b-dsDNA) for the efficient capture of specific autoantibodies that are enzymatically labeled with horseradish peroxidase (HRP) enzyme using specific secondary antibodies for each isotype or a mixture of secondary antibodies for the total content of the three isotypes. Transduction was performed by amperometry (-0.20 V vs. the Ag pseudo-reference electrode) using the H2O2/hydroquinone (HQ) system after trapping the resulting magnetic bioconjugates on each of the four working electrodes of a disposable quadruple transduction platform (SP4CEs). The bioplatform demonstrated attractive operational characteristics for clinical application and was employed to determine the individual or total hIgs classes in serum from healthy individuals and from patients diagnosed with SLE and AD. The target concentrations in AD patients are provided for the first time in this work. In addition, the results for SLE patients and control individuals agree with those obtained by applying ELISA tests as well as with the clinical ranges reported by other authors, using individual detection methodologies restricted to centralized settings or clinical laboratories.
Collapse
Affiliation(s)
- Beatriz Arévalo
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28014, Madrid, Spain
| | - Verónica Serafín
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28014, Madrid, Spain
| | - Maria Garranzo-Asensio
- Chronic Disease Programme, UFIEC, Institute of Health Carlos III, Majadahonda, 28220, Madrid, Spain
| | - Ana Montero-Calle
- Chronic Disease Programme, UFIEC, Institute of Health Carlos III, Majadahonda, 28220, Madrid, Spain
| | - Rodrigo Barderas
- Chronic Disease Programme, UFIEC, Institute of Health Carlos III, Majadahonda, 28220, Madrid, Spain
| | - Paloma Yáñez-Sedeño
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28014, Madrid, Spain.
| | - Susana Campuzano
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28014, Madrid, Spain.
| | - José M Pingarrón
- Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28014, Madrid, Spain
| |
Collapse
|
6
|
Song M, Bai H, Zhang P, Zhou X, Ying B. Promising applications of human-derived saliva biomarker testing in clinical diagnostics. Int J Oral Sci 2023; 15:2. [PMID: 36596771 PMCID: PMC9810734 DOI: 10.1038/s41368-022-00209-w] [Citation(s) in RCA: 43] [Impact Index Per Article: 43.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 10/23/2022] [Accepted: 11/03/2022] [Indexed: 01/05/2023] Open
Abstract
Saliva testing is a vital method for clinical applications, for its noninvasive features, richness in substances, and the huge amount. Due to its direct anatomical connection with oral, digestive, and endocrine systems, clinical usage of saliva testing for these diseases is promising. Furthermore, for other diseases that seeming to have no correlations with saliva, such as neurodegenerative diseases and psychological diseases, researchers also reckon saliva informative. Tremendous papers are being produced in this field. Updated summaries of recent literature give newcomers a shortcut to have a grasp of this topic. Here, we focused on recent research about saliva biomarkers that are derived from humans, not from other organisms. The review mostly addresses the proceedings from 2016 to 2022, to shed light on the promising usage of saliva testing in clinical diagnostics. We recap the recent advances following the category of different types of biomarkers, such as intracellular DNA, RNA, proteins and intercellular exosomes, cell-free DNA, to give a comprehensive impression of saliva biomarker testing.
Collapse
Affiliation(s)
- Mengyuan Song
- grid.13291.380000 0001 0807 1581Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Hao Bai
- grid.13291.380000 0001 0807 1581Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Ping Zhang
- grid.13291.380000 0001 0807 1581State Key Laboratory of Oral Diseases & Human Saliva Laboratory & National Clinical Research Center for Oral Diseases & West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Xuedong Zhou
- grid.13291.380000 0001 0807 1581State Key Laboratory of Oral Diseases & Human Saliva Laboratory & National Clinical Research Center for Oral Diseases & West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Binwu Ying
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China.
| |
Collapse
|
7
|
Are aptamer-based biosensing approaches a good choice for female fertility monitoring? A comprehensive review. Biosens Bioelectron 2022; 220:114881. [DOI: 10.1016/j.bios.2022.114881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 09/23/2022] [Accepted: 11/02/2022] [Indexed: 11/09/2022]
|