Rezvany MR, Moradi Hasan-Abad A, Sobhani-Nasab A, Esmaili MA. Evaluation of bacterial safety approaches of platelet blood concentrates: bacterial screening and pathogen reduction. Front Med (Lausanne) 2024; 11:1325602. [PMID: 38651065 PMCID: PMC11034438 DOI: 10.3389/fmed.2024.1325602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 03/04/2024] [Indexed: 04/25/2024] Open
Abstract
This mini-review analyzed two approaches to screening bacterial contamination and utilizing pathogen reduction technology (PRT) for Platelet concentrates (PCs). While the culture-based method is still considered the gold standard for detecting bacterial contamination in PCs, efforts in the past two decades to minimize transfusion-transmitted bacterial infections (TTBIs) have been insufficient to eliminate this infectious threat. PRTs have emerged as a crucial tool to enhance safety and mitigate these risks. The evidence suggests that the screening strategy for bacterial contamination is more successful in ensuring PC quality, decreasing the necessity for frequent transfusions, and improving resistance to platelet transfusion. Alternatively, the PRT approach is superior regarding PC safety. However, both methods are equally effective in managing bleeding. In conclusion, PRT can become a more prevalent means of safety for PCs compared to culture-based approaches and will soon comprehensively surpass culture-based bacterial contamination detection methods.
Collapse
Affiliation(s)
- Mohammad Reza Rezvany
- Department of Hematology, Faculty of Allied Medicine, Iran University of Medical Sciences, Tehran, Iran
- BioClinicum, Department of Oncology-Pathology, Karolinska Institute, Stockholm, Sweden
- Pediatrics Growth and Development Research Center, Institute of Endocrinology and Metabolism, Iran University of Medical Sciences, Tehran, Iran
| | - Amin Moradi Hasan-Abad
- Autoimmune Diseases Research Center, Shahid Beheshti Hospital, Kashan University of Medical Sciences, Kashan, Iran
| | - Ali Sobhani-Nasab
- Physiology Research Center, Institute for Basic Sciences, Kashan University of Medical Sciences, Kashan, Iran
| | - Mohammad Ali Esmaili
- Department of Laboratory Sciences, Sirjan School of Medical Sciences, Sirjan, Iran
| |
Collapse
|
2
|
Gravemann U, Handke W, Schulze TJ, Seltsam A. Growth and Distribution of Bacteria in Contaminated Whole Blood and Derived Blood Components. Transfus Med Hemother 2024; 51:76-83. [PMID: 38584696 PMCID: PMC10996057 DOI: 10.1159/000536242] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Accepted: 01/10/2024] [Indexed: 04/09/2024] Open
Abstract
Introduction Bacterial contamination of blood products presumably occurs mainly during blood collection, starting from low initial concentrations of 10-100 colony-forming units (CFUs) per bag. As little is known about bacterial growth behavior and distribution in stored whole blood (WB) and WB-derived blood products, this study aims to provide data on this subject. Methods WB units were inoculated with transfusion-relevant bacterial species (Acinetobacter baumannii, Bacillus cereus, Escherichia coli, Klebsiella pneumoniae, Listeria monocytogenes, Pseudomonas fluorescens, Serratia marcescens, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus dysgalactiae, Streptococcus pyogenes, Yersinia enterocolitica; n = 12 for each species), stored for 22-24 h at room temperature, and then centrifuged for separation into plasma, red blood cells (RBCs), and buffy coats (BCs). The latter were pooled with 3 random donor BCs and one unit of PAS-E each to yield plasma-reduced platelet concentrates (PCs). Samples for bacterial colony counting were collected after WB storage and immediately after blood component production. Sterility testing in PCs (n = 12 for each species) was performed by bacterial culture after 7 days of storage. Results Bacterial growth in WB varied remarkably between donations and species. Streptococcus species produced the highest titers in WB, whereas Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, and Pseudomonas fluorescens did not multiply. Centrifugation resulted in preferential accumulation of bacteria in BCs, with titers of up to 3.5 × 103 CFU/mL in BCs and up to ≤0.9 × 103 CFU/mL in BC-derived PCs. Overall, 72/144 PCs (50%) tested positive for bacteria after storage. Sterility test results were species-dependent, ranging from 12 of 12 PCs tested positive for Streptococcus pyogenes to 1 of 12 PCs positive for Escherichia coli. Bacterial contamination of RBC and plasma units was much less common and was associated with higher initial bacterial counts in the parent WB units. Conclusions Bacterial growth in WB is species-dependent and varies greatly between donations. Preferential accumulation of bacteria in BCs during manufacturing is a critical determinant of the contamination risk of BC-derived pooled PCs.
Collapse
Affiliation(s)
- Ute Gravemann
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Wiebke Handke
- Bavarian Red Cross Blood Service, Institute Nuremberg, Nuremberg, Germany
| | - Torsten J. Schulze
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Axel Seltsam
- Bavarian Red Cross Blood Service, Institute Nuremberg, Nuremberg, Germany
| |
Collapse
|
3
|
Jacobs MR, Zhou B, Tayal A, Maitta RW. Bacterial Contamination of Platelet Products. Microorganisms 2024; 12:258. [PMID: 38399662 PMCID: PMC10891786 DOI: 10.3390/microorganisms12020258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 01/18/2024] [Accepted: 01/22/2024] [Indexed: 02/25/2024] Open
Abstract
Transfusion of bacterially contaminated platelets, although rare, is still a major cause of mortality and morbidity despite the introduction of many methods to limit this over the past 20 years. The methods used include improved donor skin disinfection, diversion of the first part of donations, use of apheresis platelet units rather than whole-blood derived pools, primary and secondary testing by culture or rapid test, and use of pathogen reduction. Primary culture has been in use the US since 2004, using culture 24 h after collection of volumes of 4-8 mL from apheresis collections and whole-blood derived pools inoculated into aerobic culture bottles, with limited use of secondary testing by culture or rapid test to extend shelf-life from 5 to 7 days. Primary culture was introduced in the UK in 2011 using a "large-volume, delayed sampling" (LVDS) protocol requiring culture 36-48 h after collection of volumes of 16 mL from split apheresis units and whole-blood derived pools, inoculated into aerobic and anaerobic culture bottles (8 mL each), with a shelf-life of 7 days. Pathogen reduction using amotosalen has been in use in Europe since 2002, and was approved for use in the US in 2014. In the US, recent FDA guidance, effective October 2021, recommended several strategies to limit bacterial contamination of platelet products, including pathogen reduction, variants of the UK LVDS method and several two-step strategies, with shelf-life ranging from 3 to 7 days. The issues associated with bacterial contamination and these strategies are discussed in this review.
Collapse
Affiliation(s)
- Michael R. Jacobs
- Department of Pathology, Case Western Reserve University and University Hospitals Cleveland Medical Center, Cleveland, OH 44106, USA; (B.Z.); (A.T.); (R.W.M.)
| | | | | | | |
Collapse
|
4
|
Walker BS, Schmidt RL, White SK, Metcalf RA. Meta-analysis of bacterial growth characteristics in platelet components: Refining the inputs of a simulation analysis comparing the relative safety of testing strategies. Transfusion 2023; 63:1719-1727. [PMID: 37589199 DOI: 10.1111/trf.17497] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 06/20/2023] [Accepted: 06/28/2023] [Indexed: 08/18/2023]
Abstract
BACKGROUND The relative safety of bacterial risk control strategies for platelets that include culture with or without rapid testing has been compared using simulation analysis. A wide range of bacterial lag and doubling times were included. However, published data on growth rates are available and these data have not been synthesized. We conducted a systematic review and meta-analysis to estimate growth rates and used these estimates to refine a comparative safety analysis of bacterial risk control strategies in the FDA guidance STUDY DESIGN AND METHODS: Data were extracted from published studies on bacterial growth rates in platelet components during storage. These data were used to estimate the practical range of growth rates. This refined the inputs for a simulation model comparing the safety of the testing strategies. RESULTS In total, 108 growth curves for 11 different aerobic organisms were obtained. Doubling times ranged from 0.8 to 12 h, but the lower 90% range was approximately 1-5 h. The revised comparative safety simulation using the narrower 1-5-h range showed similar rankings to the prior simulation, with 48-h large-volume delayed sampling with 7-day expiration (48C-7) demonstrating the lowest-ranking relative performance at the 103 and 105 colony forming unit (CFU)/mL exposure thresholds. DISCUSSION This was a two-step study. First, meta-analysis of published data on aerobic bacterial growth rates in stored platelets showed the vast majority of doubling times were 1-5 h. Next, an updated comparative safety simulation yielded similar results to a prior study, with 48C-7 showing the least favorable relative safety performance.
Collapse
Affiliation(s)
| | - Robert L Schmidt
- ARUP Laboratories, Salt Lake City, Utah, USA
- Department of Pathology, University of Utah, Salt Lake City, Utah, USA
| | - Sandra K White
- Department of Pathology, University of Utah, Salt Lake City, Utah, USA
| | - Ryan A Metcalf
- ARUP Laboratories, Salt Lake City, Utah, USA
- Department of Pathology, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
5
|
Drummond MR, dos Santos LS, Fávaro RS, Stucchi RSB, Boin IDFSF, Velho PENF. Cryptogenic hepatitis patients have a higher Bartonella sp.-DNA detection in blood and skin samples than patients with non-viral hepatitis of known cause. PLoS Negl Trop Dis 2022; 16:e0010603. [PMID: 35849566 PMCID: PMC9292087 DOI: 10.1371/journal.pntd.0010603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Accepted: 06/23/2022] [Indexed: 11/21/2022] Open
Abstract
Background This study aimed to assess the prevalence of Bartonella sp.-DNA detection in blood and skin samples from patients with non-viral end-stage liver disease awaiting liver transplantation. Methodology/Principal findings Blood samples and healthy skin fragments from 50 patients were tested using microbiological and molecular methods. Fifteen patients had cryptogenic hepatitis (CH) and 35 had alcoholic, drug-induced or autoimmune liver disease. DNA was extracted from whole blood and liquid culture samples, isolates, and skin fragments. Thirteen of the 50 patients (26%) had Bartonella henselae DNA detection in their blood (9/50) and/or skin (5/50) samples. Colonies were isolated in 3/50 (6%) and infection was detected in 7/50 (14%) of the 50 patients. B. henselae-DNA detection was more prevalent in patients with CH than in other patients (p = 0.040). Of 39 patients followed-up for at least two years, a higher mortality rate was observed among patients with CH infected with B. henselae (p = 0.039). Conclusions/Significance Further studies assessing the role of B. henselae infection in the pathogenesis of hepatitis patients must be urgently conducted. One in four patients with end-stage liver disease awaiting liver transplantation for hepatitis of non-viral origin had documented B. henselae-DNA detection and cryptogenic hepatitis patients have a higher bacterium molecular detection than patients with non-viral hepatitis of known cause.
Collapse
Affiliation(s)
- Marina Rovani Drummond
- Applied Research in Dermatology and Bartonella Infection Laboratory, University of Campinas, UNICAMP, Campinas, São Paulo, Brazil
| | - Luciene Silva dos Santos
- Applied Research in Dermatology and Bartonella Infection Laboratory, University of Campinas, UNICAMP, Campinas, São Paulo, Brazil
| | | | | | | | - Paulo Eduardo Neves Ferreira Velho
- Applied Research in Dermatology and Bartonella Infection Laboratory, University of Campinas, UNICAMP, Campinas, São Paulo, Brazil
- Division of Dermatology, Department of Medicine, UNICAMP, Campinas, São Paulo, Brazil
- * E-mail:
| |
Collapse
|
6
|
Stewart CF, Tomb RM, Ralston HJ, Armstrong J, Anderson JG, MacGregor SJ, Atreya CD, Maclean M. Violet-blue 405-nm Light-based Photoinactivation for Pathogen Reduction of Human Plasma Provides Broad Antibacterial Efficacy Without Visible Degradation of Plasma Proteins. Photochem Photobiol 2021; 98:504-512. [PMID: 34935147 DOI: 10.1111/php.13584] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Accepted: 12/15/2021] [Indexed: 11/28/2022]
Abstract
In transfusion medicine, bacterial contamination can occur in ex vivo stored blood plasma, and there are continued efforts to improve blood safety and reduce the risk of transfusion-transmitted infections. Visible 405-nm violet-blue light has demonstrated potential for in situ pathogen reduction in ex vivo stored plasma and platelet concentrates. This study investigates the broad-spectrum antibacterial efficacy and compatibility potential of 405-nm light for treatment of blood plasma. Human plasma seeded with bacteria at a range of densities (101 -103 , 104 -106 , 107 -108 CFU mL-1 ) was exposed to 360 J cm-2 405-nm light (1 h at 0.1 W cm-2 ), with this fixed dose selected based on the initial analysis of inactivation kinetics. One-dimensional protein mobility analysis and measurement of advanced oxidation protein products (AOPP) was conducted to evaluate compatibility of the antimicrobial dose with plasma proteins and, identify upper levels at which protein degradation can be detected. Broad-spectrum antibacterial efficacy was observed with a fixed treatment of 360 J cm-2 , with 98.9-100% inactivation achieved across all seeding densities for all organisms, except E. coli, which achieved 95.1-100% inactivation. At this dose (360 J cm-2 ), no signs of protein degradation occurred. Overall, 405-nm light shows promise for broad-spectrum bacterial inactivation in blood plasma, while preserving plasma protein integrity.
Collapse
Affiliation(s)
- Caitlin F Stewart
- The Robertson Trust Laboratory for Electronic Sterilisation Technologies (ROLEST), Department of Electronic & Electrical Engineering, University of Strathclyde, Glasgow, UK
| | - Rachael M Tomb
- The Robertson Trust Laboratory for Electronic Sterilisation Technologies (ROLEST), Department of Electronic & Electrical Engineering, University of Strathclyde, Glasgow, UK
| | - Heather J Ralston
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Jack Armstrong
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - John G Anderson
- The Robertson Trust Laboratory for Electronic Sterilisation Technologies (ROLEST), Department of Electronic & Electrical Engineering, University of Strathclyde, Glasgow, UK
| | - Scott J MacGregor
- The Robertson Trust Laboratory for Electronic Sterilisation Technologies (ROLEST), Department of Electronic & Electrical Engineering, University of Strathclyde, Glasgow, UK
| | - Chintamani D Atreya
- Office of Blood Research and Review, Center for Biologics Evaluation and Research (CBER), Food and Drug Administration, Silver Spring, MD
| | - Michelle Maclean
- The Robertson Trust Laboratory for Electronic Sterilisation Technologies (ROLEST), Department of Electronic & Electrical Engineering, University of Strathclyde, Glasgow, UK.,Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| |
Collapse
|
7
|
Wilson-Nieuwenhuis J, El-Mohtadi M, Edwards K, Whitehead K, Dempsey-Hibbert N. Factors Involved in the onset of infection following bacterially contaminated platelet transfusions. Platelets 2021; 32:909-918. [PMID: 32762589 DOI: 10.1080/09537104.2020.1803253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Transfusion of platelet concentrates (PCs) is associated with several adverse patient reactions, the most common of which are febrile non-hemolytic transfusion reactions (FNHTRs) and transfusion-associated bacterial-infection/transfusion-associated sepsis (T-ABI/TA-S). Diagnosis of T-ABI/T-AS requires a positive blood culture (BC) result from the transfusion recipient and also a positive identification of bacterial contamination within a test aliquot of the transfused PC. In a significant number of cases, clinical symptoms post-transfusion are reported by the clinician, yet the BCs from the patient and/or PC are negative. The topic of 'missed bacterial detection' has therefore been the focus of several primary research studies and review articles, suggesting that biofilm formation in the blood bag and the presence of viable but non-culturable (VBNC) pathogens are the major causes of this missed detection. However, platelets are emerging as key players in early host responses to infection and as such, the aforementioned biofilm formation could elicit 'platelet priming', which could lead to significant immunological reactions in the host, in the absence of planktonic bacteria in the host bloodstream. This review reflects on what is known about missed detection and relates this to the emerging understanding of the effect of bacterial contamination on the platelets themselves and the significant role played by platelets in exacerbation of an immune response to infection within the transfusion setting.
Collapse
Affiliation(s)
| | - Mohamed El-Mohtadi
- Centre for Bioscience, Manchester Metropolitan University, Manchester, UK
| | - Kurtis Edwards
- Centre for Bioscience, Manchester Metropolitan University, Manchester, UK
| | - Kathryn Whitehead
- Centre for Bioscience, Manchester Metropolitan University, Manchester, UK
| | | |
Collapse
|
8
|
Ye H, Xu H, Qiao M, Guo R, Ji Y, Yu Y, Chen Y, Gai X, Li H, Liu Q, Zhuang Y. MicroRNA expression profiles analysis of apheresis platelets treated with vitamin B 2 and ultraviolet-B during storage. Transfus Apher Sci 2021; 60:103079. [PMID: 33602623 DOI: 10.1016/j.transci.2021.103079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 01/30/2021] [Accepted: 02/04/2021] [Indexed: 11/18/2022]
Abstract
Whether platelet (PLT) microRNA (miRNA) profiles are affected by pathogen reduction technology (PRT) using vitamin B2 and ultraviolet-B (VB2-PRT) remains unclear. Samples from VB2-PRT-treated (experimental group, E_) and untreated (control group, C_) apheresis PLTs were taken on days 1, 3 and 5 of storage, designated as E_1, E_3, E_5, C_1, C_3 and C_5, respectively. The miRNA expression profiles were assessed by DNA Nano Ball (DNB) sequencing technology, and verified by quantitive real-time fluorescence quantitative PCR (qRT-PCR). Compared with the expression profiles of PLT miRNAs, 3895 miRNAs were identified in the E_ groups while 4106 were in the C_ groups. There were 487 significant differentially expressed miRNAs in E_1 vs C_1 group, including 220 upregulated and 287 downregulated, such as miR-146a-5p and let-7b-5p. There were 908 significant differentially expressed miRNAs in E_3 vs C_3 group, including 297 upregulated and 611 downregulated, such as miR-142-5p and miR-7-5p. There were 229 significant differentially expressed miRNAs in E_5 vs C_5 group, including 80 upregulated and 149 downregulated, such as miR-3529-3p and miR-451a. These differentially expressed miRNAs had been suggested to have functional roles in energy homeostasis, cell communication, proliferation, migration and apoptosis. GO analysis showed a significant enrichmen in relevant biological process categories as receptor activity, signal transduction, cell transport, motility and chemotaxis. The significantly enriched KEGG pathway of predicted target genes was Glycosaminoglycan biosynthesis in E_ vs C_ groups. These new observation could provide insights on the understanding of change of miRNA profiles of PLT treated with VB2-PRT.
Collapse
Affiliation(s)
- Hui Ye
- Institute of Hematology, Blood Center of Shandong Province, Jinan 250014, Shandong Province, China; School of Medicine, Shandong University, Jinan 250012, Shandong Province, China
| | - Huicong Xu
- Domestic Marketing System of Shenzhen Mindray Biomedical Electronics Co, Ltd, Jinan 250012, Shandong Province, China
| | - Mingming Qiao
- Institute of Hematology, Blood Center of Shandong Province, Jinan 250014, Shandong Province, China
| | - Rui Guo
- Shandong Provincial Qianfoshan Hospital, the First Hospital Affiliated With Shandong First Medical University, Jinan 250014, Shandong Province, China
| | - Yanbo Ji
- Shandong Provincial Qianfoshan Hospital, the First Hospital Affiliated With Shandong First Medical University, Jinan 250014, Shandong Province, China
| | - Yuan Yu
- Institute of Hematology, Blood Center of Shandong Province, Jinan 250014, Shandong Province, China
| | - Yuanfeng Chen
- Institute of Hematology, Blood Center of Shandong Province, Jinan 250014, Shandong Province, China
| | - Xia Gai
- Institute of Hematology, Blood Center of Shandong Province, Jinan 250014, Shandong Province, China
| | - Honglei Li
- School of Medicine, Shandong University, Jinan 250012, Shandong Province, China
| | - Qun Liu
- Institute of Hematology, Blood Center of Shandong Province, Jinan 250014, Shandong Province, China
| | - Yunlong Zhuang
- Institute of Hematology, Blood Center of Shandong Province, Jinan 250014, Shandong Province, China.
| |
Collapse
|
9
|
Walker BS, Schmidt RL, Fisher MA, White SK, Blaylock RC, Metcalf RA. The comparative safety of bacterial risk control strategies for platelet components: a simulation study. Transfusion 2020; 60:1723-1731. [PMID: 32632927 DOI: 10.1111/trf.15919] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 05/07/2020] [Accepted: 05/13/2020] [Indexed: 11/30/2022]
Abstract
BACKGROUND Bacterial contamination of platelets is a problem that can lead to harmful septic transfusion reactions. The US Food and Drug Administration published a guidance in September 2019 detailing several permissible risk control strategies. Our objective was to compare the safety of each bacterial testing strategy for apheresis platelets. STUDY DESIGN AND METHODS We used simulation to compare safety of the nine risk control strategies involving apheresis platelet testing. The primary outcome was the risk of exposure. An exposure event occurred if a patient received platelets exceeding a specific contamination threshold (>0, 103 , and 105 colony-forming units (CFU/mL). We generated a range of bacterial contamination scenarios (inoculum size, doubling time, lag time) and compared risk of exposure for each policy in each contamination scenario. We then computed the average risk difference over all scenarios. RESULTS At the 0 CFU/mL exposure threshold, two-step policies that used secondary culture ranked best (all top three), while single-step 24-hour culture with 3-day expiration ranked last (ninth). This latter policy performed well (median rank of 1) at both the 103 and 105 CFU/mL thresholds, but 48-hour culture with 7-day expiration performed relatively poorly. At these higher thresholds, median ranks of two-step policies that used secondary culture were again top three. Two-step policies that used rapid testing improved at the higher (105 CFU/mL) harm threshold, with median rankings between 1 and 5. CONCLUSION Two-step policies that used secondary culture were generally safer than single-step policies. Performance of two-step policies that used rapid testing depended on the CFU per milliter threshold of exposure used.
Collapse
Affiliation(s)
- Brandon S Walker
- Department of Pathology and ARUP Laboratories, University of Utah, Salt Lake City, Utah, USA
| | - Robert L Schmidt
- Department of Pathology and ARUP Laboratories, University of Utah, Salt Lake City, Utah, USA
| | - Mark A Fisher
- Department of Pathology and ARUP Laboratories, University of Utah, Salt Lake City, Utah, USA
| | - Sandra K White
- Department of Pathology and ARUP Laboratories, University of Utah, Salt Lake City, Utah, USA
| | - Robert C Blaylock
- Department of Pathology and ARUP Laboratories, University of Utah, Salt Lake City, Utah, USA
| | - Ryan A Metcalf
- Department of Pathology and ARUP Laboratories, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
10
|
New strategies for the control of infectious and parasitic diseases in blood donors: the impact of pathogen inactivation methods. EUROBIOTECH JOURNAL 2020. [DOI: 10.2478/ebtj-2020-0007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Abstract
Around 70 infectious agents are possible threats for blood safety.
The risk for blood recipients is increasing because of new emergent agents like West Nile, Zika and Chikungunya viruses, or parasites such as Plasmodium and Trypanosoma cruzi in non-endemic regions, for instance.
Screening programmes of the donors are more and more implemented in several Countries, but these cannot prevent completely infections, especially when they are caused by new agents.
Pathogen inactivation (PI) methods might overcome the limits of the screening and different technologies have been set up in the last years.
This review aims to describe the most widely used methods focusing on their efficacy as well as on the preservation integrity of blood components.
Collapse
|
11
|
Satake M, Kozakai M, Matsumoto M, Matsubayashi K, Taira R, Goto N. Platelet safety strategies in Japan: impact of short shelf life on the incidence of septic reactions. Transfusion 2020; 60:731-738. [PMID: 32119134 DOI: 10.1111/trf.15733] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Revised: 01/17/2020] [Accepted: 01/29/2020] [Indexed: 12/14/2022]
Abstract
BACKGROUND Transfusion-transmitted bacterial infections (TTBIs) often have serious consequences for patients. The Japanese Red Cross (JRC) has not implemented culture screening for platelet concentrate (PC), but it has maintained a shelf life of 85 hours for PC. STUDY DESIGN AND METHODS The JRC collected reports of suspected TTBI and investigated causal relationships using PC samples and patient blood samples. PCs showing apparent abnormalities were retrieved and cultured and analyzed for bacterial growth. RESULTS The JRC analyzed 86 samples available from 135 transfused PCs with suspected TTBIs that were collected over the past 12 years; 17 (19.8%) were culture-positive. One, 6, and 10 TTBIs developed in patients on Days 1, 2, and 3 after PC collection, respectively. Assuming that PC is transfused on the day of issue, the TTBI risk was fourfold higher on Day 3 than on Day 2, after adjusting the TTBI incidence for the number of PCs issued per day. Compared with the model of issuing all PCs on Day 3, issuing PCs with the current distribution of storage time could have decreased the TTBI incidence by 56%. During the past 8 years, the JRC retrieved 960 PC units because of apparent abnormalities, 2.8% of which were culture-positive. CONCLUSION The short shelf life of PC is associated with a low incidence of reported TTBIs, more than half of which occurred on Day 3 relative to earlier time points. Visual inspection of PC before transfusion is crucial in detecting bacterially contaminated PC despite its low positive predictive value.
Collapse
Affiliation(s)
- Masahiro Satake
- Central Blood Institute, Japanese Red Cross, Tokyo, Japan.,Blood Service Headquarters, Japanese Red Cross, Tokyo, Japan
| | - Moe Kozakai
- Central Blood Institute, Japanese Red Cross, Tokyo, Japan
| | - Mami Matsumoto
- Central Blood Institute, Japanese Red Cross, Tokyo, Japan
| | | | - Rikizo Taira
- Blood Service Headquarters, Japanese Red Cross, Tokyo, Japan
| | - Naoko Goto
- Blood Service Headquarters, Japanese Red Cross, Tokyo, Japan
| |
Collapse
|
12
|
Banerjee T, Tummala T, Elliott R, Jain V, Brantley W, Hadorn L, Santra S. Multimodal Magneto-Fluorescent Nanosensor for Rapid and Specific Detection of Blood-Borne Pathogens. ACS APPLIED NANO MATERIALS 2019; 2:5587-5593. [PMID: 34222829 PMCID: PMC8247792 DOI: 10.1021/acsanm.9b01158] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Detection of bacterial contaminants in blood and platelet concentrates (PCs) continues to be challenging in clinical settings despite available current testing methods. At the same time, it is important to detect the low bacterial contaminants present at the time of transfusion. Herein, we report the design and synthesis of a dual-modal magneto-fluorescent nanosensor (MFnS) by integrating magnetic relaxation and fluorescence modalities for the wide-range detection of blood-borne pathogens. In this study, functional MFnS are designed to specifically detect Staphylococcus epidermidis and Escherichia coli, two of the predominant bacterial contaminants of PCs. Specific interaction between the target pathogen and functional MFnS resulted in the change of water proton's magnetic relaxation time (T2 MR), indicative of sensitive detection of the target bacteria from low to high colony forming unit (CFU). In addition, the acquired MR signal of MFnS further facilitated the quantitative assessment of the slow and fast growth kinetics of target pathogens. Moreover, the presence of fluorescence modality in MFnS allowed for the detection of multi-contaminants. The bacterial detection was also performed in complex media including whole blood and platelet concentrates, which further demonstrated for it's robust detection sensitivity. Overall, our study indicated that the designer MFnS will have potential for the wide-range detection of blood-borne pathogens, and features desirable qualities including timeliness, sensitivity and, specificity.
Collapse
Affiliation(s)
- Tuhina Banerjee
- Department of Chemistry, Pittsburg State University, 1701 S. Broadway Street, Pittsburg, KS 66762, USA
| | - Tanuja Tummala
- Department of Chemistry, Pittsburg State University, 1701 S. Broadway Street, Pittsburg, KS 66762, USA
| | - Rebekah Elliott
- Department of Chemistry, Pittsburg State University, 1701 S. Broadway Street, Pittsburg, KS 66762, USA
| | - Vedant Jain
- Department of Chemistry, Pittsburg State University, 1701 S. Broadway Street, Pittsburg, KS 66762, USA
| | - Wesley Brantley
- Department of Chemistry, Pittsburg State University, 1701 S. Broadway Street, Pittsburg, KS 66762, USA
| | - Laci Hadorn
- Department of Chemistry, Pittsburg State University, 1701 S. Broadway Street, Pittsburg, KS 66762, USA
| | - Santimukul Santra
- Department of Chemistry, Pittsburg State University, 1701 S. Broadway Street, Pittsburg, KS 66762, USA
| |
Collapse
|
13
|
Ramirez‐Arcos S, McDonald C, Deol P, Kreuger AL, Patel N, Pidcoke H, Prax M, Seltsam A, Stassinopoulos A. Bacterial safety of blood components–a congress review of the ISBT transfusion‐transmitted infectious diseases working party, bacterial subgroup. ACTA ACUST UNITED AC 2019. [DOI: 10.1111/voxs.12483] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
| | | | | | | | | | | | | | - Axel Seltsam
- German Red Cross Blood Service NSTOB Springe Germany
| | | | | |
Collapse
|
14
|
Gravemann U, Handke W, Müller TH, Seltsam A. Bacterial inactivation of platelet concentrates with the THERAFLEX UV-Platelets pathogen inactivation system. Transfusion 2018; 59:1324-1332. [PMID: 30588633 DOI: 10.1111/trf.15119] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 11/27/2018] [Accepted: 12/03/2018] [Indexed: 12/13/2022]
Abstract
BACKGROUND The THERAFLEX UV-Platelets system (Maco Pharma) uses ultraviolet C (UVC) light for pathogen inactivation (PI) of platelet concentrates (PCs) without any additional photoactive compound. The aim of the study was to systematically investigate bacterial inactivation with this system under conditions of intended use. STUDY DESIGN AND METHODS The robustness of the system was evaluated by assessing its capacity to inactivate high concentrations of different bacterial species in accordance with World Health Organization guidelines. The optimal use of the PI system was explored in time-to-treatment experiments by testing its ability to sterilize PCs contaminated with low levels of bacteria on the day of manufacture (target concentration, 100 colony-forming units/unit). The bacteria panel used for spiking experiments in this study included the World Health Organization International Repository Platelet Transfusion Relevant Reference Strains (n = 14), commercially available strains (n = 13), and in-house clinical isolates (n = 2). RESULTS Mean log reduction factors after UVC treatment ranged from 3.1 to 7.5 and varied between different strains of the same species. All PCs (n = 12/species) spiked with up to 200 colony-forming units/bag remained sterile until the end of storage when UVC treated 6 hours after spiking. UVC treatment 8 hours after spiking resulted in single breakthrough contaminations with the fast-growing species Escherichia coli and Streptococcus pyogenes. CONCLUSION The UVC-based THERAFLEX UV-Platelets system efficiently inactivates transfusion-relevant bacterial species in PCs. The comprehensive data from this study may provide a valuable basis for the optimal use of this UVC-based PI system.
Collapse
Affiliation(s)
- Ute Gravemann
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Wiebke Handke
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Thomas H Müller
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| | - Axel Seltsam
- German Red Cross Blood Service NSTOB, Institute Springe, Springe, Germany
| |
Collapse
|
15
|
Brecher ME. Do older platelets increase the risk of transfusion-associated sepsis? Transfusion 2018; 58:1-2. [PMID: 29314102 DOI: 10.1111/trf.14433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Accepted: 11/02/2017] [Indexed: 11/26/2022]
Affiliation(s)
- Mark E Brecher
- Laboratory Corporation of America Diagnostics, Burlington, NC.,Department of Pathology and Laboratory Medicine, University of North Carolina, Durham, NC
| |
Collapse
|
16
|
Kreuger AL, Rostgaard K, Middelburg RA, Kerkhoffs JLH, Edgren G, Erikstrup C, Pedersen OB, Titlestad K, Nielsen KR, Ostrowski SR, Voldstedlund M, van der Bom JG, Ullum H, Hjalgrim H. Storage time of platelet concentrates and risk of a positive blood culture: a nationwide cohort study. Transfusion 2017; 58:16-24. [PMID: 29168187 DOI: 10.1111/trf.14401] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2017] [Revised: 09/20/2017] [Accepted: 09/20/2017] [Indexed: 01/28/2023]
Abstract
BACKGROUND Concern of transfusion-transmitted bacterial infections has been the major hurdle to extend shelf life of platelet (PLT) concentrates. We aimed to investigate the association between storage time and risk of positive blood cultures at different times after transfusion. STUDY DESIGN AND METHODS We performed a nationwide cohort study among PLT transfusion recipients in Denmark between 2010 and 2012, as recorded in the Scandinavian Donations and Transfusions (SCANDAT2) database. Linking with a nationwide database on blood cultures (MiBa), we compared the incidence of a positive blood culture among recipients of PLTs stored 6 to 7 days (old) to those receiving fresh PLTs (1-5 days), using Poisson regression models. We considered cumulative exposures in windows of 1, 3, 5, and 7 days. RESULTS A total of 9776 patients received 66,101 PLT transfusions. The incidence rate ratio (IRR) of a positive blood culture the day after transfusion of at least one old PLT concentrate was 0.77 (95% confidence interval [CI], 0.54-1.09) compared to transfusion of fresh PLT concentrates. The incidence rate of a positive blood culture was lower the day after receiving one old compared to one fresh PLT concentrate (IRR, 0.57; 95% CI, 0.37-0.87). Three, 5, or 7 days after transfusion, storage time was not associated with the risk of a positive blood culture. CONCLUSION Storage of buffy coat-derived PLT concentrates in PAS-C up to 7 days seems safe regarding the risk of a positive blood culture. If anything, transfusion of a single old PLT concentrate may decrease this risk the following day.
Collapse
Affiliation(s)
- Aukje L Kreuger
- Center for Clinical Transfusion Research, Sanquin Research, Leiden, the Netherlands.,Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Klaus Rostgaard
- Department of Epidemiology Research, Statens Serum Institut, Copenhagen, Denmark
| | - Rutger A Middelburg
- Center for Clinical Transfusion Research, Sanquin Research, Leiden, the Netherlands.,Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Jean-Louis H Kerkhoffs
- Center for Clinical Transfusion Research, Sanquin Research, Leiden, the Netherlands.,Haga Hospital, Den Haag, the Netherlands
| | - Gustav Edgren
- Department of Medical Epidemiology and Biostatistics, Karolinska Institutet, Stockholm, Sweden.,Hematology Center, Karolinska University Hospital, Stockholm, Sweden
| | - Christian Erikstrup
- Department of Clinical Immunology, Aarhus University Hospital, Aarhus, Denmark
| | - Ole B Pedersen
- Department of Clinical Immunology, Naestved Hospital, Naestved, Denmark
| | - Kjell Titlestad
- Department of Clinical Immunology, Odense University Hospital, Odense, Denmark
| | - Kaspar R Nielsen
- Department of Clinical Immunology, Aalborg University Hospital, Aalborg, Denmark
| | - Sisse R Ostrowski
- Department of Clinical Immunology, the Blood Bank, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark
| | - Marianne Voldstedlund
- Department of Infectious Disease Epidemiology, Statens Serum Institut, Copenhagen, Denmark
| | - Johanna G van der Bom
- Center for Clinical Transfusion Research, Sanquin Research, Leiden, the Netherlands.,Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Henrik Ullum
- Department of Clinical Immunology, the Blood Bank, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark
| | - Henrik Hjalgrim
- Department of Epidemiology Research, Statens Serum Institut, Copenhagen, Denmark
| |
Collapse
|
17
|
Kreuger AL, Middelburg RA, Kerkhoffs JLH, Schipperus MR, Wiersum-Osselton JC, van der Bom JG. Storage medium of platelet transfusions and the risk of transfusion-transmitted bacterial infections. Transfusion 2017; 57:657-660. [PMID: 28144957 DOI: 10.1111/trf.13969] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 10/13/2016] [Accepted: 11/08/2016] [Indexed: 12/20/2022]
Abstract
BACKGROUND Transfusion-transmitted bacterial infections (TTBIs) are among the most concerning risks of transfusion of platelet (PLT) concentrates. Storage medium influences bacterial growth dynamics and thereby the sensitivity of screening tests for bacterial contamination. STUDY DESIGN AND METHODS The aim of this study was to quantify the association of storage media with the incidence of TTBIs after transfusion of PLT concentrates. In the Netherlands, the choice of storage medium is determined solely by geographic location of the hospital. We compared types of storage medium of all reported cases of TTBIs after transfusion of a PLT concentrate with types of storage medium of all produced PLT concentrates in the Netherlands from 2003 to 2014. RESULTS Fourteen cases of TTBIs were reported, of which 57.1% received a PLT concentrate stored in PLT additive solution (PAS) and 42.9% a PLT concentrate stored in plasma. Of all produced PLT concentrates 22.3% were stored in PAS and 77.7% in plasma. The relative risk of TTBI after transfusion of a PAS-stored PLT concentrate was 4.63 (95% confidence interval [CI], 1.4-16.2) compared to transfusion of a plasma-stored PLT concentrate. The incidence of TTBIs was 22.2 per million (95% CI, 12.1-37.2 per million) transfused buffy coat PLT concentrates. CONCLUSION Transfusion of PAS-stored PLT concentrates is associated with a fourfold increased incidence of TTBIs, compared to plasma-stored PLT concentrates.
Collapse
Affiliation(s)
- Aukje L Kreuger
- Center for Clinical Transfusion Research, Sanquin Research, Leiden University Medical Center, Leiden, the Netherlands.,Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Rutger A Middelburg
- Center for Clinical Transfusion Research, Sanquin Research, Leiden University Medical Center, Leiden, the Netherlands.,Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Jean-Louis H Kerkhoffs
- Center for Clinical Transfusion Research, Sanquin Research, Leiden University Medical Center, Leiden, the Netherlands.,Haga Hospital, Den Haag, the Netherlands
| | - Martin R Schipperus
- Haga Hospital, Den Haag, the Netherlands.,TRIP, Transfusion and Transplantation Reactions in Patients, Dutch National Hemovigilance Office, Leiden, the Netherlands
| | - Johanna C Wiersum-Osselton
- TRIP, Transfusion and Transplantation Reactions in Patients, Dutch National Hemovigilance Office, Leiden, the Netherlands
| | - Johanna G van der Bom
- Center for Clinical Transfusion Research, Sanquin Research, Leiden University Medical Center, Leiden, the Netherlands.,Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
18
|
A New Proof of Concept in Bacterial Reduction: Antimicrobial Action of Violet-Blue Light (405 nm) in Ex Vivo Stored Plasma. JOURNAL OF BLOOD TRANSFUSION 2016; 2016:2920514. [PMID: 27774337 PMCID: PMC5059568 DOI: 10.1155/2016/2920514] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Accepted: 08/28/2016] [Indexed: 11/17/2022]
Abstract
Bacterial contamination of injectable stored biological fluids such as blood plasma and platelet concentrates preserved in plasma at room temperature is a major health risk. Current pathogen reduction technologies (PRT) rely on the use of chemicals and/or ultraviolet light, which affects product quality and can be associated with adverse events in recipients. 405 nm violet-blue light is antibacterial without the use of photosensitizers and can be applied at levels safe for human exposure, making it of potential interest for decontamination of biological fluids such as plasma. As a pilot study to test whether 405 nm light is capable of inactivating bacteria in biological fluids, rabbit plasma and human plasma were seeded with bacteria and treated with a 405 nm light emitting diode (LED) exposure system (patent pending). Inactivation was achieved in all tested samples, ranging from low volumes to prebagged plasma. 99.9% reduction of low density bacterial populations (≤103 CFU mL−1), selected to represent typical “natural” contamination levels, was achieved using doses of 144 Jcm−2. The penetrability of 405 nm light, permitting decontamination of prebagged plasma, and the nonrequirement for photosensitizing agents provide a new proof of concept in bacterial reduction in biological fluids, especially injectable fluids relevant to transfusion medicine.
Collapse
|
19
|
Chatterjee K, Zaman S, Chaurasia R, Singh S, Keil SD, Tewari S, Bisht A, Agarwal N, Rout D, Chand S, Saha K. Evaluation of Mirasol pathogen reduction system by artificially contaminating platelet concentrates with Staphylococcus epidermidis: A pilot study from India. Asian J Transfus Sci 2016; 10:127-31. [PMID: 27605849 PMCID: PMC4993081 DOI: 10.4103/0973-6247.187946] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND AND OBJECTIVES This study was conducted to assess the efficacy of Mirasol pathogen reduction system for platelets aimed at preventing bacterial regrowth by spiking buffy coat pooled platelets (BCPP) with clinically relevant load of Staphylococous epidermidis. MATERIALS AND METHODS BCPP units were prepared using Teruflex BP-kit with Imugard III-S-PL (Terumo BCT, Tokyo, Japan). Two BCPP units were pooled, of which 40 ml of negative control (NC) was removed. The remaining volume of the platelet unit was inoculated with clinically relevant load of bacteria (total of 30 CFU of S. epidermidis in 1 ml); following this the platelet unit was split into two parts. One part served as positive control (PC) and the other part was subjected to pathogen reduction technique (Mirasol PRT, CaridianBCT Biotechnologies, Lakewood, CO, USA). Bacterial detection was performed using BacT/ALERT system, controls after day 1 and day 7 following inoculation of bacteria and on day 7 for Mirasol-treated unit. RESULTS Of the 32 treatment cycles, 28 were valid and 4 were invalid. No regrowth was observed in 96.4% (27 of 28) after treatment with Mirasol pathogen reduction system. Of four invalid tests, on two instances the NC showed growth, whereas in other 2 no regrowth was detected in 7(th) day PC. Bacterial screening of PCs by BacT/ALERT after 24 h of incubation was 28.6%, whereas the effectiveness increased to 100% when incubated for 7 days. CONCLUSIONS Mirasol system was effective in inactivating S. epidermidis when it was deliberately inoculated into BCPP at clinically relevant concentrations. Such systems may significantly improve blood safety by inactivating traditional and emerging transfusion-transmitted pathogens.
Collapse
Affiliation(s)
- Kabita Chatterjee
- Department of Transfusion Medicine, All Institute of Medical Sciences, New Delhi, India
| | - Shamsuz Zaman
- Department of Transfusion Medicine, All Institute of Medical Sciences, New Delhi, India
| | - Rahul Chaurasia
- Department of Transfusion Medicine, All Institute of Medical Sciences, New Delhi, India
| | - Surinder Singh
- National Institute of Biologicals, Noida, Uttar Pradesh, India
| | | | - Shalini Tewari
- National Institute of Biologicals, Noida, Uttar Pradesh, India
| | - Akanksha Bisht
- Haemovigilance Programme, National Institute of Biologicals, Noida, Uttar Pradesh, India
| | - Nitin Agarwal
- Department of Transfusion Medicine, All Institute of Medical Sciences, New Delhi, India
| | - Diptiranjan Rout
- Department of Transfusion Medicine, All Institute of Medical Sciences, New Delhi, India
| | - Subhash Chand
- National Institute of Biologicals, Noida, Uttar Pradesh, India
| | - Kallol Saha
- National Institute of Biologicals, Noida, Uttar Pradesh, India
| |
Collapse
|
20
|
Keil SD, Hovenga N, Gilmour D, Marschner S, Goodrich R. Treatment of Platelet Products with Riboflavin and UV Light: Effectiveness Against High Titer Bacterial Contamination. J Vis Exp 2015:e52820. [PMID: 26327141 PMCID: PMC4692557 DOI: 10.3791/52820] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Contamination of platelet units by bacteria has long been acknowledged as a significant transfusion risk due to their post-donation storage conditions. Products are routinely stored at 22 °C on an agitating shaker, a condition that can promote bacterial growth. Although the total number of bacteria believed to be introduced into a platelet product is extremely low, these bacteria can multiply to a very high titer prior to transfusion, potentially resulting in serious adverse events. The aim of this study was to evaluate a riboflavin based pathogen reduction process against a panel of bacteria that have been identified as common contaminants of platelet products. This panel included the following organisms: S. epidermidis, S. aureus, S. mitis, S. pyogenes, S. marcescens, Y. enterocolitica, B. neotomae, B. cereus, E. coli, P. aeruginosa and K. pneumoniae. Each platelet unit was inoculated with a high bacterial load and samples were removed both before and after treatment. A colony forming assay, using an end point dilution scheme, was used to determine the pre-treatment and post-treatment bacterial titers. Log reduction was calculated by subtracting the post-treatment titer from the pre-treatment titer. The following log reductions were observed: S. epidermidis 4.7 log (99.998%), S. aureus 4.8 log (99.998%), S. mitis 3.7 log (99.98%), S. pyogenes 2.6 log (99.7%), S. marcescens 4.0 log (99.99%), Y. enterocolitica 3.3 log (99.95%), B. neotomae 5.4 log (99.9996%), B. cereus 2.6 log (99.7%), E. coli ≥5.4 log (99.9996%), P. aeruginosa 4.7 log (99.998%) and K. pneumoniae 2.8 log (99.8%). The results from this study suggest the process could help to lower the risk of severe adverse transfusion events associated with bacterial contamination.
Collapse
|
21
|
Benjamin RJ. Pathogen inactivation - defining ‘adequate’ bacterial protection. ACTA ACUST UNITED AC 2014. [DOI: 10.1111/voxs.12057] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- R. J. Benjamin
- American Red Cross Holland Laboratories; Rockville MD USA
| |
Collapse
|
22
|
The International Experience of Bacterial Screen Testing of Platelet Components With an Automated Microbial Detection System: A Need for Consensus Testing and Reporting Guidelines. Transfus Med Rev 2014; 28:61-71. [DOI: 10.1016/j.tmrv.2014.01.001] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2013] [Revised: 01/25/2014] [Accepted: 01/27/2014] [Indexed: 11/30/2022]
|
23
|
El Ichi S, Leon F, Vossier L, Marchandin H, Errachid A, Coste J, Jaffrezic-Renault N, Fournier-Wirth C. Microconductometric immunosensor for label-free and sensitive detection of Gram-negative bacteria. Biosens Bioelectron 2014; 54:378-84. [DOI: 10.1016/j.bios.2013.11.016] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Revised: 10/18/2013] [Accepted: 11/05/2013] [Indexed: 12/11/2022]
|
24
|
Bioresponsive polymers for the detection of bacterial contaminations in platelet concentrates. N Biotechnol 2014; 31:150-5. [DOI: 10.1016/j.nbt.2013.11.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2013] [Accepted: 11/09/2013] [Indexed: 02/02/2023]
|
25
|
Vollmer T, Knabbe C, Dreier J. Novel flow cytometric screening method for bacterial contamination of red blood cells: a proof-of-principle evaluation. Transfusion 2013; 54:900-9. [DOI: 10.1111/trf.12513] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2013] [Revised: 10/19/2013] [Accepted: 10/20/2013] [Indexed: 11/28/2022]
Affiliation(s)
- Tanja Vollmer
- Institut für Laboratoriums- und Transfusionsmedizin; Herz- und Diabeteszentrum Nordrhein-Westfalen; Universitätsklinik der Ruhr-Universität Bochum; Bad Oeynhausen Germany
| | - Cornelius Knabbe
- Institut für Laboratoriums- und Transfusionsmedizin; Herz- und Diabeteszentrum Nordrhein-Westfalen; Universitätsklinik der Ruhr-Universität Bochum; Bad Oeynhausen Germany
| | - Jens Dreier
- Institut für Laboratoriums- und Transfusionsmedizin; Herz- und Diabeteszentrum Nordrhein-Westfalen; Universitätsklinik der Ruhr-Universität Bochum; Bad Oeynhausen Germany
| |
Collapse
|
26
|
Hahn S, Sireis W, Hourfar K, Karpova D, Dauber K, Kempf VAJ, Seifried E, Schmidt M, Bönig H. Effects of storage temperature on hematopoietic stability and microbial safety of BM aspirates. Bone Marrow Transplant 2013; 49:338-48. [PMID: 24185589 DOI: 10.1038/bmt.2013.176] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Revised: 09/06/2013] [Accepted: 09/24/2013] [Indexed: 12/31/2022]
Abstract
Bone marrow (BM) remains a common source for hematopoietic SCT. Due to the transcutaneous approach, contamination with skin bacteria is common. The delay between harvest and transfusion can be considerable, potentially allowing for bacterial proliferation. The optimal transportation temperature, specifically with respect to bacterial growth and consequences thereof for hematopoietic quality, remain undefined. For 72 h, 66 individual BM samples, non-spiked/spiked with different bacteria, stored at 20-24 °C room temperature (RT) or 3-5 °C (cold), were serially analyzed for hematopoietic quality and microbial burden. Under most conditions, hematopoietic quality of BM was equal or better at RT: Typical BM contaminants (P. acnes and S. epidermidis) and E. coli were killed or bacterial proliferation was arrested at RT; hematopoietic quality was not impacted by the contamination. However, several pathogenic bacteria not typically found in BM (S. aureus and K. pneumoniae) proliferated dramatically at RT and impaired hematopoietic quality. Bacterial proliferation was arrested in the cold. The overwhelming majority of BM samples, that is, those that are sterile or contaminated only with skin commensals, will benefit from transportation at RT. Those bacteria that proliferate and perturb hematopoietic quality are not typically found in BM. Our data support recommendations for RT transportation and storage of BM.
Collapse
Affiliation(s)
- S Hahn
- German Red Cross Blood Service Baden-Wuerttemberg-Hessen and Institute for Transfusion Medicine and Immunohematology, Goethe University Medical Center, Frankfurt, Germany
| | - W Sireis
- German Red Cross Blood Service Baden-Wuerttemberg-Hessen and Institute for Transfusion Medicine and Immunohematology, Goethe University Medical Center, Frankfurt, Germany
| | - K Hourfar
- German Red Cross Blood Service Baden-Wuerttemberg-Hessen and Institute for Transfusion Medicine and Immunohematology, Goethe University Medical Center, Frankfurt, Germany
| | - D Karpova
- German Red Cross Blood Service Baden-Wuerttemberg-Hessen and Institute for Transfusion Medicine and Immunohematology, Goethe University Medical Center, Frankfurt, Germany
| | - K Dauber
- German Red Cross Blood Service Baden-Wuerttemberg-Hessen and Institute for Transfusion Medicine and Immunohematology, Goethe University Medical Center, Frankfurt, Germany
| | - V A J Kempf
- Institute for Medical Microbiology and Infection Control, Goethe University Medical Center, Frankfurt, Germany
| | - E Seifried
- German Red Cross Blood Service Baden-Wuerttemberg-Hessen and Institute for Transfusion Medicine and Immunohematology, Goethe University Medical Center, Frankfurt, Germany
| | - M Schmidt
- German Red Cross Blood Service Baden-Wuerttemberg-Hessen and Institute for Transfusion Medicine and Immunohematology, Goethe University Medical Center, Frankfurt, Germany
| | - H Bönig
- 1] German Red Cross Blood Service Baden-Wuerttemberg-Hessen and Institute for Transfusion Medicine and Immunohematology, Goethe University Medical Center, Frankfurt, Germany [2] Department of Medicine/Hematology, University of Washington, Seattle, WA, USA
| |
Collapse
|
27
|
So BKL, Chu CCY, Ho PL, Chow KH, Leung JNS, Lee IYM, Lin CK, Lee CK. Evaluation of two chlorhexidine - alcohol-based skin disinfectants in blood donation setting. Vox Sang 2013; 106:316-21. [DOI: 10.1111/vox.12107] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Affiliation(s)
- B. K. L. So
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong SAR China
| | - C. C. Y. Chu
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong SAR China
| | - P. L. Ho
- Carol Yu Center for Infection and Department of Microbiology; the University of Hong Kong; Hong Kong SAR China
| | - K. H. Chow
- Carol Yu Center for Infection and Department of Microbiology; the University of Hong Kong; Hong Kong SAR China
| | - J. N. S. Leung
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong SAR China
| | - I. Y. M. Lee
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong SAR China
| | - C. K. Lin
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong SAR China
| | - C. K. Lee
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong SAR China
| |
Collapse
|
28
|
Benjamin RJ, Dy B, Perez J, Eder AF, Wagner SJ. Bacterial culture of apheresis platelets: a mathematical model of the residual rate of contamination based on unconfirmed positive results. Vox Sang 2013; 106:23-30. [DOI: 10.1111/vox.12065] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2013] [Revised: 06/04/2013] [Accepted: 06/04/2013] [Indexed: 11/28/2022]
Affiliation(s)
- R. J. Benjamin
- American Red Cross Biomedical Services; Rockville MD USA
| | - B. Dy
- American Red Cross Biomedical Services; Rockville MD USA
| | - J. Perez
- American Red Cross Biomedical Services; Rockville MD USA
| | - A. F. Eder
- American Red Cross Biomedical Services; Rockville MD USA
| | - S. J. Wagner
- American Red Cross Biomedical Services; Rockville MD USA
| |
Collapse
|
29
|
Affiliation(s)
- C. P. McDonald
- National Bacteriology Laboratory; National Health Service Blood and Transplant; London; UK
| |
Collapse
|
30
|
Seltsam A, Müller TH. Update on the use of pathogen-reduced human plasma and platelet concentrates. Br J Haematol 2013; 162:442-54. [PMID: 23710899 DOI: 10.1111/bjh.12403] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The use of pathogen reduction technologies (PRTs) for labile blood components is slowly but steadily increasing. While pathogen-reduced plasma is already used routinely, efficacy and safety concerns impede the widespread use of pathogen-reduced platelets. The supportive and often prophylactic nature of blood component therapy in a variety of clinical situations complicates the clinical evaluation of these novel blood products. However, an increasing body of evidence on the clinical efficacy, safety, cost-benefit ratio and development of novel technologies suggests that pathogen reduction has entered a stage of maturity that could further increase the safety margin in haemotherapy. This review summarizes the clinical evidence on PRTs for plasma and platelet products that are currently licensed or under development.
Collapse
Affiliation(s)
- Axel Seltsam
- Institute Springe, German Red Cross Blood Service NSTOB, Springe, Germany.
| | | |
Collapse
|
31
|
Garson JA, Patel P, McDonald C, Ball J, Rosenberg G, Tettmar KI, Brailsford SR, Pitt T, Tedder RS. Evaluation of an ethidium monoazide-enhanced 16S rDNA real-time polymerase chain reaction assay for bacterial screening of platelet concentrates and comparison with automated culture. Transfusion 2013; 54:870-8. [PMID: 23701338 PMCID: PMC4282358 DOI: 10.1111/trf.12256] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2013] [Revised: 04/11/2013] [Accepted: 04/15/2013] [Indexed: 12/01/2022]
Abstract
BACKGROUND Culture-based systems are currently the preferred means for bacterial screening of platelet (PLT) concentrates. Alternative bacterial detection techniques based on nucleic acid amplification have also been developed but these have yet to be fully evaluated. In this study we evaluate a novel 16S rDNA polymerase chain reaction (PCR) assay and compare its performance with automated culture. STUDY DESIGN AND METHODS A total of 2050 time-expired, 176 fresh, and 400 initial-reactive PLT packs were tested by real-time PCR using broadly reactive 16S primers and a "universal" probe (TaqMan, Invitrogen). PLTs were also tested using a microbial detection system (BacT/ALERT, bioMérieux) under aerobic and anaerobic conditions. RESULTS Seven of 2050 (0.34%) time-expired PLTs were found repeat reactive by PCR on the initial nucleic acid extract but none of these was confirmed positive on testing frozen second aliquots. BacT/ALERT testing also failed to confirm any time-expired PLTs positive on repeat testing, although 0.24% were reactive on the first test. Three of the 400 "initial-reactive" PLT packs were found by both PCR and BacT/ALERT to be contaminated (Escherichia coli, Listeria monocytogenes, and Streptococcus vestibularis identified) and 14 additional packs were confirmed positive by BacT/ALERT only. In 13 of these cases the contaminating organisms were identified as anaerobic skin or oral commensals and the remaining pack was contaminated with Streptococcus pneumoniae. CONCLUSION These results demonstrate that the 16S PCR assay is less sensitive than BacT/ALERT and inappropriate for early testing of concentrates. However, rapid PCR assays such as this may be suitable for a strategy of late or prerelease testing.
Collapse
Affiliation(s)
- Jeremy A Garson
- National Transfusion Microbiology Laboratories, NHSBT/HPA Epidemiology Unit, NHS Blood and Transplant, Colindale, London; Research Department of Infection, Division of Infection and Immunity, University College London, London; Blood Borne Virus Unit, Viral Reference Department, Centre for Infections, Health Protection Agency, Colindale, London, UK
| | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Kawasato KH, de Oliveira LC, Velho PENF, Yamamoto L, Del Negro GMB, Okay TS. Detection of Bartonella henselae DNA in clinical samples including peripheral blood of immune competent and immune compromised patients by three nested amplifications. Rev Inst Med Trop Sao Paulo 2013; 55:1-6. [PMID: 23328718 DOI: 10.1590/s0036-46652013000100001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2012] [Accepted: 08/20/2012] [Indexed: 11/22/2022] Open
Abstract
Bacteria of the genus Bartonella are emerging pathogens detected in lymph node biopsies and aspirates probably caused by increased concentration of bacteria. Twenty-three samples of 18 patients with clinical, laboratory and/or epidemiological data suggesting bartonellosis were subjected to three nested amplifications targeting a fragment of the 60-kDa heat shock protein (HSP), the internal transcribed spacer 16S-23S rRNA (ITS) and the cell division (FtsZ) of Bartonella henselae, in order to improve detection in clinical samples. In the first amplification 01, 04 and 05 samples, were positive by HSP (4.3%), FtsZ (17.4%) and ITS (21.7%), respectively. After the second round six positive samples were identified by nested-HSP (26%), eight by nested-ITS (34.8%) and 18 by nested-FtsZ (78.2%), corresponding to 10 peripheral blood samples, five lymph node biopsies, two skin biopsies and one lymph node aspirate. The nested-FtsZ was more sensitive than nested-HSP and nested-ITS (p < 0.0001), enabling the detection of Bartonella henselae DNA in 15 of 18 patients (83.3%). In this study, three nested-PCR that should be specific for Bartonella henselae amplification were developed, but only the nested-FtsZ did not amplify DNA from Bartonella quintana. We conclude that nested amplifications increased detection of B. henselae DNA, and that the nested-FtsZ was the most sensitive and the only specific to B. henselae in different biological samples. As all samples detected by nested-HSP and nested-ITS, were also by nested-FtsZ, we infer that in our series infections were caused by Bartonella henselae. The high number of positive blood samples draws attention to the use of this biological material in the investigation of bartonellosis, regardless of the immune status of patients. This fact is important in the case of critically ill patients and young children to avoid more invasive procedures such as lymph nodes biopsies and aspirates.
Collapse
Affiliation(s)
- Karina Hatamoto Kawasato
- Children's Institute, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil.
| | | | | | | | | | | |
Collapse
|
33
|
Lee CK, Wong HK, Ho PL, Tsoi WC, Lee KY, Tsui GTF, Chua E, Leung JNS, Lin CK. Significant bacterial contamination risk reduction with the use of diversion pouch. Transfus Med 2012; 22:404-8. [DOI: 10.1111/j.1365-3148.2012.01194.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2012] [Revised: 09/05/2012] [Accepted: 09/09/2012] [Indexed: 11/30/2022]
Affiliation(s)
- C. K. Lee
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - H. K. Wong
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - P. L. Ho
- Department of Microbiology; The University of Hong Kong; Hong Kong; SAR; China
| | - W. C. Tsoi
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - K. Y. Lee
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - G. T. F. Tsui
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - E. Chua
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - J. N. S. Leung
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| | - C. K. Lin
- Hong Kong Red Cross Blood Transfusion Service; Hong Kong; SAR; China
| |
Collapse
|
34
|
Schmidt M, Seifried E. Current status of bacterial detection in blood components - successes and challenges. ACTA ACUST UNITED AC 2012. [DOI: 10.1111/j.1751-2824.2012.01545.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
35
|
Reid S, Johnson L, Woodland N, Marks DC. Pathogen reduction treatment of buffy coat platelet concentrates in additive solution induces proapoptotic signaling. Transfusion 2012; 52:2094-103. [PMID: 22320126 DOI: 10.1111/j.1537-2995.2011.03558.x] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Pathogen reduction technology (PRT) can potentially reduce the risk of transfusion-transmitted infections. However, PRT treatment of platelet (PLT) concentrates also results in reduced PLT quality and increased markers of apoptosis during storage. The aim of this study was to investigate changes to the expression and activation of proteins involved in apoptosis signaling. STUDY DESIGN AND METHODS Samples from riboflavin and ultraviolet light PRT-treated and untreated (control) buffy coat-derived PCs in 70% SSP+ and 30% plasma were taken on Days 1, 5, and 7 of storage. Phosphatidylserine (PS) exposure, expression of Bcl-2 family proteins, cytochrome c release, and cleavage of caspase-3 and caspase-3 substrates were analyzed using flow cytometry and Western blotting. RESULTS Compared to untreated controls, markers of apoptosis signaling were increased after PRT and subsequent storage. PS exposure on the PLT outer membrane was significantly higher after PRT on Days 5 and 7 of storage (p < 0.05). Expression of proapoptotic Bak and Bax was higher after PRT and subsequent storage. Cytochrome c release and caspase-3 cleavage were also greater and occurred earlier in the PRT-treated PLTs. The cleavage of caspase-3 substrates gelsolin and ROCK I were also increased after PRT, compared to untreated controls. CONCLUSIONS This study demonstrated an increase in proapoptotic signaling during PLT storage, which was exacerbated by PRT. Many of these differences emerged outside the current 5-day storage period. These changes may not currently influence PLT transfusion quality, but will need to be carefully evaluated when considering extending PLT storage beyond 5 days.
Collapse
Affiliation(s)
- Samantha Reid
- Research and Development, Australian Red Cross Blood Service, and the School of Medical and Molecular Biosciences, University of Technology, Sydney, New South Wales, Australia
| | | | | | | |
Collapse
|
36
|
Patel P, Garson JA, Tettmar KI, Ancliff S, McDonald C, Pitt T, Coelho J, Tedder RS. Development of an ethidium monoazide-enhanced internally controlled universal 16S rDNA real-time polymerase chain reaction assay for detection of bacterial contamination in platelet concentrates. Transfusion 2011; 52:1423-32. [PMID: 22188457 DOI: 10.1111/j.1537-2995.2011.03484.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Bacterial contamination of platelet (PLT) concentrates remains a problem for blood transfusion services. Culture-based bacterial screening techniques are available but offer inadequate speed and sensitivity. Alternative techniques based on polymerase chain reaction (PCR) amplification have been described but their performance is often compromised by traces of bacterial DNA in reagents. STUDY DESIGN AND METHODS Universal 16S rDNA primers were used to develop a real-time PCR assay (TaqMan, Applied Biosystems) and various reagent decontamination strategies were explored. Detection sensitivity was assessed by spiking PLT concentrates with known concentrations of 13 different organisms. RESULTS Restriction enzyme digestion, master mix ultrafiltration, and use of alternative Taq polymerases all reduced the level of reagent DNA contamination to some extent but all proved unreliable. In contrast, ethidium monoazide (EMA) treatment of the PCR master mix followed by photoactivation was reliable and effective, permitting a full 40 amplification cycles, and totally eliminated contamination without compromising assay sensitivity. All 13 organisms were efficiently detected and the limit of detection for Escherichia coli-spiked PLTs was approximately 1 colony-forming unit/mL. Coamplification of human mitochondrial DNA served to confirm efficient nucleic acid extraction and the absence of PCR inhibition in each sample. One of five automated extraction platforms evaluated was found to be contamination free and capable of high-throughput processing. CONCLUSION Cross-linking of EMA to DNA via photoactivation solved the previously intractable problem of reagent contamination and permitted the development of a high-sensitivity universal bacterial detection system. Trials are ongoing to assess the suitability of the system for high-throughput screening of PLT concentrates.
Collapse
Affiliation(s)
- Poorvi Patel
- National Transfusion Microbiology Laboratories, NHS Blood and Transplant, Colindale, London, UK
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Nakamura A, Abe K, Masuya M, Imai S, Ohishi K, Mori Y, Kojima T, Wada H, Katayama N, Nobori T. Efficiency of diversion of the first aliquot of blood and prestorage leukoreduction for preventing bacterial contamination in red blood cell concentrates assessed using a rapid polymerase chain reaction-based bacterial detection system. Transfus Med 2011; 21:365-70. [DOI: 10.1111/j.1365-3148.2011.01093.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
38
|
Albertoni G, Andrade SS, Araújo PRB, Carvalho FO, Girão MJBC, Barreto JA. Evaluation of two detection methods of microorganisms in platelet concentrates. Transfus Med 2011; 21:408-16. [DOI: 10.1111/j.1365-3148.2011.01105.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
39
|
Müller TH, Montag T, Seltsam AW. Laboratory Evaluation of the Effectiveness of Pathogen Reduction Procedures for Bacteria. ACTA ACUST UNITED AC 2011; 38:242-250. [PMID: 22016694 DOI: 10.1159/000330338] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2011] [Accepted: 05/05/2011] [Indexed: 11/19/2022]
Abstract
SUMMARY: Bacterial contamination remains a leading factor for transfusion-associated serious morbidity and mortality. Pathogen reduction procedures offer a pro-active approach to prevent bacterial contamination of cellular blood components and especially of platelet concentrates. In the past, the laboratory evaluation of the effectiveness of the pathogen reduction procedures to minimise the bacterial load of blood components has been primarily based on log reduction assays similar to the assessment of antiviral activities. Bacteria strains with the ability to multiply in the blood components are seeded in highest possible cell numbers, the pathogen reduction procedure is applied, and the post-treatment number of bacteria is measured. The effectiveness of the procedure is characterised by calculating the log reduction of the post- to pre-treatment bacteria titres. More recently, protocols have been developed for experiments starting with a low bacteria load and monitoring the sterility of the blood component during the entire storage period of the blood component. Results for 3 different pathogen reduction technologies in these experimental models are compared and critical determinants for the results are addressed. The heterogeneity of results observed for different strains suggests that the introduction of international transfusion-relevant bacterial reference strains may facilitate the validity of findings in pathogen reduction experiments.
Collapse
Affiliation(s)
- Thomas H Müller
- DRK-Blutspendedienst NSTOB, Institut Springe, Langen, Germany
| | | | | |
Collapse
|
40
|
Pearce S, Rowe GP, Field SP. Screening of platelets for bacterial contamination at the Welsh Blood Service. Transfus Med 2011; 21:25-32. [PMID: 20854460 DOI: 10.1111/j.1365-3148.2010.01037.x] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND AND OBJECTIVE This report details the results of the implementation of a bacterial screening system at the Welsh Blood Service and provides an estimate of the levels of bacterial contamination at the time of sampling. MATERIALS AND METHODS Apheresis (Caridian BCT) and buffy coat-derived pooled platelet components were sampled on day 1 for bacterial contamination and the sample was monitored throughout the lifespan of the platelet component. Unused platelet components were re-tested to determine the effectiveness of the screening. Results from the BacT/ALERT are uploaded to the in-house Blood Establishment Computer System (BECS) every 12 min. Positive alerts are automatically sent to staff, facilitating a timely intervention. RESULTS Between February 2003 and March 2010 the screening system tested 54 828 platelets and detected 257 (1 in 213) initial positives of which 35 (1 in 1567, 0·06%) were confirmed [95% confidence interval (CI), 0·04-0·08%]. Additionally, screening of 6438 unused platelet components detected another 6 (1 in 1073, 0·09%) confirmed positives not detected during initial testing (95% CI, 0·02-0·16%). Analysis of the data suggests that on day 1 the number of bacteria in such platelet component packs was between 5 and 62 cfus total. Day 1 culture has a sensitivity of 40%. CONCLUSIONS The bacterial screening system has removed a significant number, but not all bacterially contaminated platelet components from the supply. The sample volume is an important factor in sensitivity due to the low number of bacteria in a platelet component pack on day 1. An effective notification and recall system is a critical part of the bacterial screening system.
Collapse
Affiliation(s)
- S Pearce
- Welsh Blood Service, Laboratory Services, Pontyclun, UK.
| | | | | |
Collapse
|
41
|
Greco CA, Zhang JG, Kalab M, Yi QL, Ramirez-Arcos SM, Gyongyossy-Issa MIC. Effect of platelet additive solution on bacterial dynamics and their influence on platelet quality in stored platelet concentrates. Transfusion 2011; 50:2344-52. [PMID: 20553431 DOI: 10.1111/j.1537-2995.2010.02726.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Platelet additive solutions (PASs) are an alternative to plasma for the storage of platelet concentrates (PCs). However, little is known about the effect of PAS on the growth dynamics of contaminant bacteria. Conversely, there have been no studies on the influence of bacteria on platelet (PLT) quality indicators when suspended in PAS. STUDY DESIGN AND METHODS Eight buffy coats were pooled, split, and processed into PCs suspended in either plasma or PAS (SSP+, MacoPharma). PCs were inoculated with 10 and 100 colony-forming units (CFUs)/bag of either Serratia liquefaciens or Staphylococcus epidermidis. Bacterial growth was measured over 5 days by colony counts and bacterial biofilm formation was assayed by scanning electron microscopy and crystal violet staining. Concurrently, PLT markers were measured by an assay panel and flow cytometry. RESULTS S. liquefaciens exhibited an apparent slower doubling time in plasma-suspended PCs (plasma-PCs). Biofilm formation by S. liquefaciens and S. epidermidis was significantly greater in PCs stored in plasma than in PAS. Although S. liquefaciens altered several PLT quality markers by Days 3 to 4 postinoculation in both PAS- and plasma-PCs, S. epidermidis contamination did not produce measurable PLT changes. CONCLUSIONS S. liquefaciens can be detected more quickly in PAS-suspended PCs (PAS-PCs) than in plasma-PCs by colony counting. Furthermore, reduced biofilm formation by S. liquefaciens and S. epidermidis during storage in PAS-PCs increases bacteria availability for sampling detection. Culture-based detection remains the earliest indicator of bacterial presence in PAS-PCs, while changes of PLT quality can herald S. liquefaciens contamination when in excess of 10(8) CFUs/mL.
Collapse
|
42
|
Rood IGH, de Korte D, Ramírez-Arcos S, Savelkoul PHM, Pettersson A. Distribution, origin and contamination risk of coagulase-negative staphylococci from platelet concentrates. J Med Microbiol 2011; 60:592-599. [PMID: 21212143 DOI: 10.1099/jmm.0.023176-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Transfusion-associated bacterial sepsis is the most common microbiological risk of transfusion and is caused mostly by platelet concentrates (PCs). The most frequently identified bacterial contaminants of PCs are coagulase-negative staphylococci (CNS). In order to learn more about the distribution, source and risk of the CNS that are involved in bacterial contamination of PCs, CNS strains isolated during platelet screening were collected and characterized to the species level with three different methods: 16S rRNA and sodA gene sequencing, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and amplified fragment length polymorphism (AFLP) analysis. AFLP analysis was also used for the typing of the CNS strains. A total of 83 CNS strains were analysed by sequencing and 8 different CNS species were identified, with Staphylococcus epidermidis being the predominant species. MALDI-TOF MS and AFLP analysis confirmed these results to a large extent. However, MALDI_TOF MS could not identify all strains to the species level and AFLP analysis revealed an additional, likely novel, CNS species. The species identified are mainly recognized as being part of the normal skin flora. Typing of the CNS strains by AFLP analysis showed that there was not a unique strain which is significantly more often present during bacterial contamination of PCs.
Collapse
Affiliation(s)
- Ineke G H Rood
- Department of Medical Microbiology and Infection Control, VU University Medical Center, Amsterdam, The Netherlands
- Department of Blood Cell Research, Sanquin Research, Amsterdam, The Netherlands
| | - Dirk de Korte
- Department of Blood Cell Research, Sanquin Research, Amsterdam, The Netherlands
| | | | - Paul H M Savelkoul
- Department of Medical Microbiology and Infection Control, VU University Medical Center, Amsterdam, The Netherlands
| | - Annika Pettersson
- Department of Medical Microbiology and Infection Control, VU University Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
43
|
Yomtovian R, Jacobs MR. A prospective bonus of platelet storage additive solutions: a reduction in biofilm formation and improved bacterial detection during platelet storage. Transfusion 2010; 50:2295-300. [PMID: 21182629 DOI: 10.1111/j.1537-2995.2010.02894.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
44
|
Goodrich RP, Custer B, Keil S, Busch M. Defining "adequate" pathogen reduction performance for transfused blood components. Transfusion 2010; 50:1827-37. [PMID: 20374558 DOI: 10.1111/j.1537-2995.2010.02635.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Pathogen reduction of labile blood products offers the opportunity to introduce to the blood banking community the same mechanism of protection that is employed for fractionated or pooled plasma products today--blood components that have been treated with methods to inactivate or reduce the infectivity of a variety of organisms that may contaminate donated blood and thus potentially transmit infection via transfusion. Due to the mechanisms of action, the methods employed in the plasma fractionation environment are not directly applicable to labile blood products. This article examines whether the same criteria of performance required for plasma derivatives (i.e., 6 log/mL reduction by multiple orthogonal methods) should be applied to the treatment of labile components and if not what criteria for performance might be sufficient. In conducting this analysis, we have considered what has been learned in the past several decades regarding the dynamics and infectivity of various pathogens and disease transmission by blood products, the introduction and progressive enhancement of testing methods based on serology and nucleic acid testing, and the performance characteristics for pathogen reduction technologies that are available today.
Collapse
|
45
|
Martínez F, Tarrand J, Lichtiger B. Impact on patient outcome following transfusion of bacterially contaminated platelets: the M.D. Anderson Cancer Center experience. Am J Clin Pathol 2010; 134:207-12. [PMID: 20660322 DOI: 10.1309/ajcps9yv7ytomrrh] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
This study examined the clinical outcome of every patient who received a bacterially contaminated unit of platelets at The University of Texas M.D. Anderson Cancer Center, Houston, during 2007. Samples of platelets were aerobically cultured and read for 1 day at 35 degrees C. Positive bottles were subcultured in the appropriate media. The effect of independent variables in the clinical outcome of patients infused with bacterially contaminated platelet units was analyzed. A total of 23,199 platelet units were transfused, 71 of which were bacterially contaminated units; 8 were apheresis platelets and 63 were whole blood platelets. Of the 71 units, 70 were contaminated with gram-positive bacteria and 1 with gram-negative bacteria. Only 1 patient developed fever, and coagulase-negative staphylococci were isolated from the transfused unit. Transfusion of fresh units and antibiotic therapy possibly explain the lack of clinical consequences in our patients.
Collapse
|
46
|
Vamvakas EC, Blajchman MA. Blood still kills: six strategies to further reduce allogeneic blood transfusion-related mortality. Transfus Med Rev 2010; 24:77-124. [PMID: 20303034 PMCID: PMC7126657 DOI: 10.1016/j.tmrv.2009.11.001] [Citation(s) in RCA: 104] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
After reviewing the relative frequency of the causes of allogeneic blood transfusion-related mortality in the United States today, we present 6 possible strategies for further reducing such transfusion-related mortality. These are (1) avoidance of unnecessary transfusions through the use of evidence-based transfusion guidelines, to reduce potentially fatal (infectious as well as noninfectious) transfusion complications; (2) reduction in the risk of transfusion-related acute lung injury in recipients of platelet transfusions through the use of single-donor platelets collected from male donors, or female donors without a history of pregnancy or who have been shown not to have white blood cell (WBC) antibodies; (3) prevention of hemolytic transfusion reactions through the augmentation of patient identification procedures by the addition of information technologies, as well as through the prevention of additional red blood cell alloantibody formation in patients who are likely to need multiple transfusions in the future; (4) avoidance of pooled blood products (such as pooled whole blood-derived platelets) to reduce the risk of transmission of emerging transfusion-transmitted infections (TTIs) and the residual risk from known TTIs (especially transfusion-associated sepsis [TAS]); (5) WBC reduction of cellular blood components administered in cardiac surgery to prevent the poorly understood increased mortality seen in cardiac surgery patients in association with the receipt of non-WBC-reduced (compared with WBC-reduced) transfusion; and (6) pathogen reduction of platelet and plasma components to prevent the transfusion transmission of most emerging, potentially fatal TTIs and the residual risk of known TTIs (especially TAS).
Collapse
Affiliation(s)
- Eleftherios C Vamvakas
- Department of Pathology and Laboratory Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
| | | |
Collapse
|
47
|
Magalhães RF, Cintra ML, Barjas-Castro ML, Del Negro GMB, Okay TS, Velho PENF. Blood donor infected with Bartonella henselae. Transfus Med 2010; 20:280-2. [DOI: 10.1111/j.1365-3148.2010.01001.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
48
|
Rood IG, Pettersson A, Savelkoul PH, De Korte D. Development of a reverse transcription-polymerase chain reaction assay for eubacterial RNA detection in platelet concentrates. Transfusion 2010; 50:1352-8. [DOI: 10.1111/j.1537-2995.2009.02580.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
49
|
Vamvakas EC. COMMENTARY: Relative safety of pooled whole blood-derived versus single-donor (apheresis) platelets in the United States: a systematic review of disparate risks. Transfusion 2009; 49:2743-58. [DOI: 10.1111/j.1537-2995.2009.02338.x] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
50
|
Eder AF, Kennedy JM, Dy BA, Notari EP, Skeate R, Bachowski G, Mair DC, Webb JS, Wagner SJ, Dodd RY, Benjamin RJ. Limiting and detecting bacterial contamination of apheresis platelets: inlet-line diversion and increased culture volume improve component safety. Transfusion 2009; 49:1554-63. [DOI: 10.1111/j.1537-2995.2009.02192.x] [Citation(s) in RCA: 102] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|